Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Correspondence
\07239: Washington Square M -58 .6td�o _ coo its. Page 1 of 2 9 CV ' Gtia4 %. Ro( Jet Edit this Draft DHC Property Development Field Order Modification , FOM #: A007239 Subject: Washington Square M -58 Status: Complete for Issue Produced by: Mitch Steinhoff Input required - Architectural Yes Complete Structural No Mechanical No Electrical No Specifications Yes Complete Store Planning No Company: Mervyn's Reason for issue: DHC Approved Change Requested by: Mitch Steinhoff CMT Change item #: - N/A - Do not FOM: Issue date: 26 June 2000 FOM'd Prototypes: II FOM'd Cycles: FOM'd Stores: (Remodels IlCycle 2 2000 I M -58 Configuration: RE D AR - -- --- --- ----- - - - - - -- ------ -- - -- -- - - -- - - - - -- TERRY WO EN % DHC construction to modify the following in the field: Ix p-3 Comments: o MINNEAP IS, MN • tf 3712 Q$ti Terry G. Wobken, Architect FOM #6 �i OF O�� -ADA Door Opener Architectural: - Revise Remote push operators for automatic door openers from hard wire to remote control type. -At Doors 101.4 and 101.5 provide post mount or rail type(not shown) mounting as required for remote push pad openers as required. Provide post mount per attachment a007239.pdf or approved equal. Locate as required.(revise location from wall mount) http: / /pd. partnersonline. com/ FOMS. nsf/ cicldc4f.../ ea8911ff6548851a852568f8004eba36 ?OpenDocumen 6/26/00 A ' 7239: Washington Square M -58 Page 2 of 2 Structural: N/A Mechanical: N/A Electrical: N/A Specifications: Revise Specification Section 8720 - Automatic Door Operators as indicated on attachment WASA007239.pdf Summary of Attached Drawings: Architectural: (1) 81/2" x 11" () 81/2" x 14" () full size sheet (sent to field separately) Structural: 0 81/2" x 11" () 81/2" x 14" () full size sheet (sent to field separately) Mechanical: 0 81/2" x 11" () 81/2" x 14" () full size sheet (sent to field separately) Electrical: 0 81/2" x 11" () 81/2" x 14" () full size sheet (sent to field separately) Specifications: (1) 81/2" x 11" () 81/2" x 14" Attachments: Created by: Mitch Steinhoff Date/Time: 06/08/2000 10:19 AM Edited by: Mitch Steinhoff Date/Time: 06/26/2000 05:05 PM Mitch Steinhoff 06/26/2000 04:56 PM Mitch Steinhoff 06/26/2000 04:45 PM Mitch Steinhoff 06/26/2000 04:36 PM Mitch Steinhoff 06/26/2000 04:34 PM - WASA007239.pdf a007239.pdf http: / /pd .partnersonline.com /FOMS.nsf /c1 c1 dc4f... /ea8911 ff6548851 a852568f8004eba36 ?OpenDocumen 6/26/00 PYRAMID POST CAP -ALL WELDS GROUND SMOOTH WOOD SHIM f I "x4 RADIO CONTROLLED SWITCH RECESSED IN TUBE 4 "x4'xi /8" ALUMINUM TUBE BROWN ANODIZED FINISH o TO MATCH STOREFRONT - �p o w r,' z w U- SHAPED MOUNTING BRACKET FASTENED TO CONCRETE SLAB WITH 2 - DIA. x 4' LONG 0 S/S BOLTS 3 /8° DIA THRU BOLT EXISTING SLAB 1 12" =1' -0" TERRY WOBKEN z I ©{u CU ONE HUNDRED AND TWENTY FIRST AVENUE NORTH MINNEAPOLIS MINNESOTA (612) 339 -0313 SPECIFICATION REVISIONS FOR FOM No. A007239 SECTION 08720 - AUTOMATIC DOOR OPERATORS Article 2.2 Materials, revise paragraph "C" to read as follows: C. Push Plate: Manufacturer's standard, 6 inch diameter, recessed stainless steel push plate, engraved with the words "Push to Open ". Provide narrow style wall or post mounted radio controlled ADA compliant push button activator as indicated and approiate for existing conditions, as manufactured by Besam or prior approved equal. END OF SPECIFICATION REVISIONS • 26- Jun -00 Page - 1 A007254 -2: M -58 Remodel Page 1 of 2 /3 n a•u41 Edit this Draft DHC Property Development Field Order Modification FOM #: A007254 - 2 Subject: M -58 Remodel Status: Complete for Issue Produced by: Mitch Steinhoff Input required - Architectural Yes Complete Structural No Mechanical No Electrical No Specifications No Store Planning No Company: Mervyn's Reason for issue: DHC Approved Change Requested by: Mitch Steinhoff CMT Change item #: - N/A - Do not FOM: Issue date: 23 June 2000 FOM'd Prototypes: II FOM'd Cycles: II FOM'd Stores: (Remodels IICyc1e 2 2000 I M - 58 Configuration: DHC construction to modify the following in the field: 1 AR TERRY OBKEN Comments: 1 .- Terry G. Wobken, Architect FOM #7 MINNE •OLIS, MN • -Sign Canopy CP , , 12 -Glass Rail Detail Architectural: - 1 ' OF Sheet A1A -Upper Level Floor Plan (Not Issued) - Revise General Note 'P' as follows: P. Demo existing sign cabinet and sign, for new sign installation. Pacific Neon to provide new triangular sign cabinet and sign for attachment to existing steel tube frame. Coordinate demo and installation with Pacific Neon Company. 1576 Silica Avenue. Sacramento, CA 95815. Contact: David http:// pd. partnersonline. coml foms. nsf/ cicidc4f3.../ 2dd34c8729c53d75852568ff005c8adc ?OpenDocumen 6/23/00 4007254 -2: M -58 Remodel Page 2 of 2 Randolph, 916 - 927 -0527, Ext. 214 Sheet A16A- Interior Finish Details (Portions of) - Delete Detail 5/A16A. (Not Issued) - Revise Detail 25/A16A as indicated on atachment m58 -1.pdf Revise base and rail color and expansion bolt size from FOM A007254 Structural: N/A Mechanical: N/A Electrical: N/A Specifications: N/A Summary of Attached Drawings: Architectural: (1) 81/2" x 11" () 81/2" x 14" () full size sheet (sent to field separately) Structural: () 81/2" x 11" () 81/2" x 14" () full size sheet (sent to field separately) Mechanical: 0 81/2" x 11" ()81/2 "x14" () full size sheet (sent to field separately) Electrical: () 81/2" x 11" �81/2"x14" () full size sheet (sent to field separately) Specifications: () 81/2" x 11" () 81/2" x 14" Attachments: Created by: Mitch Steinhoff DatelTime: 06/15/2000 12:50 PM Edited by: Mitch Steinhoff Date/Time: 06/23/2000 04:33 PM Mitch Steinhoff 06/23/2000 04:32 PM Mitch Steinhoff 06/23/2000 04:31 PM Mitch Steinhoff 06/23/2000 04:30 PM Mitch Steinhoff 06/23/2000 04:27 PM Th m58 -1.pdf http:// pd .partnersonline.com /foms.nsf /c1 c1 dc4f3...1 2dd34c8729c53d75852568ff005c8adc ?OpenDocumen 6/23/00 In z g TERRY WOBKEN • GO...________ aQ c rr c4 a APPROVED EQUAL. OR AL.PANT 'STAND RD SILVER' ,CODE '*49 /90380 ONE HUNDRED AND TWENTY POWDER POWDER COAT AS MFR TIGER DRYLAC. USE SMOOTH FLOW, FIRST AVENUE NORTH SEMIGLOSS SURFACE, SPECIAL SERIES 49 CLEAR COAT OVER. MINNEAPOLIS MINNESOTA (612) 339 -0313 v 1/2THICK, CLASS 2, ASTM CIO48, TYPE I, q3 QUALITY, GRADE B, HORIZONTALLY TEMPERED, CLEAR FLOAT GLASS EXPANSION CEMENT "ROCKITE° �,— MOUNTING BRACKET BASE: BLUMCRAFT RG200 OR OR APPROVED EQUAL. APPROVED EQUAL. PAINT 'STANDARD SILVER', CODE ' * 26/90380, POWDER COAT AS MFR BY TIGER DRYLAC. USE SMOOTH FLOW, SEMI GLOSS SURFACE, SPECIAL SERIES 49 CLEAR COAT OVER. 2'/z ° \ • CT -I, TYPICAL EACH SIDE 4 ■ ( ___ S CHLUTER DILEX -BWA, COLOR HB- TYPICAL OF BASE T EACH SIDE ki � EXISTING METAL DECK •9LIYLII CONCRETE C OMPOSITE � S ` —��� Ix HARD WOOD 7 / Z ' ' / // ry,/,/, r / /7 ' TRIM BOARDS IPS -7 / AA �� PAINT IPS -I, C -I E d IA r777// � 0 CONTRACTOR ° j ALTERNATE: WC -I, •NOTE: VERIFY l'-0° DIMENSION. DIMENSION MAY VAFkY �/ IF REQUIRED DUE TO DUE TO MOUNTING REQUIRMENTS AT (4) CORNER COLUMNS EXISTING CONDITIONS AND TOP RAIL CONNECTION. REVISE AS REQUIRED. %" HILTI'KWIK -BOLT II' (ICBO '*4627) ANCHORS AT 6° OC WI STANDARD EMBED. 25 GUARDRAIL @ ESCALATOR Al6A - � 3 -1 -0 U) A007216: Washington Square M -58 ,1(/%P2 - °ate f Page 1 of 3 g. Edit this Draft DHC Property Development Field Order Modification FOM #: A007216 Subject: Washington Square M -58 Status: Complete for Issue Produced by: Mitch Steinhoff Input required - Architectural Yes Complete Structural No Mechanical No Electrical Yes Complete Specifications No Store Planning No Company: Mervyn's Reason for issue: DHC Approved Change Requested by: Mitch Steinhoff CMT Change item #: - N/A - Do not FOM: Issue date: FOM'd Prototypes: II FOM'd Cycles: II FOM'd Stores: (Remodels IlCycle 2 2000 I M - 058 Configuration: DHC construction to modify the following in the field: 3 D A. ( // - • TERRY WI 'MEN EN .�� Comments: Terry Wobken, Architect FOM #5 o MINNEAP1 LIS, MN - Railing,upper level; Lights, escalator area. (A, 37 Architectural: OF 0‘ Sheet D1A -Upper Level Demolition Plan (8 -1/2" x 11" attachment) - Revise Escalator well area demolition; Revise demolition key note '5E'; Add demolition key notes '9M' and '9N'. Sheet A1A -Upper Level Floor Plan (8 -1/2" x 11" attachment) -Add detail reference at escalator well; Add detail 5 /A1A. http: / /pd. partnersonline. com/ foms. nsf/ cicidc4f3.../ e635586abbcf89f8852568e80066022f ?OpenDocumen 6/12/00 ' A007216: Washington Square M -58 Page 2 of 3 Sheet A2A -Upper Level Floor Finish & Blocking Plan (8 -1/2" x 11" attachment) - Revise keynotes at escalator well; Revise Wall Finish Note '10'. Sheet A3A -Upper Level Reflected Ceiling Plan (8 -1/2" x 11 ") - Revise escalator well area lighting and keynotes; Add Reflected Ceiling Plan Keynotes '3A' and '9'. Sheet A16A- Interior Finish Details (8 -1/2" x 11 ") -Add detail 25/A16A. Structural: N/A Mechanical: N/A Electrical: Sheet E2A: Show new lighting over escalator area. Sheet E8: Revised panelboard schedules to reflect revisions made to drawings. Specifications: N/A Summary of Attached Drawings: Architectural: (10) 81/2" x 11" () 81/2" x 14" () full size sheet (sent to field separately) ■ Structural: () 81/2" x 11" . () 81/2" x 14" () full size sheet (sent to field separately) Mechanical: () 81/2" x 11" • () 81/2" x 14" () full size sheet (sent to field separately) Electrical: (4) 81/2" x 11" ()81/2 "x14" () full size sheet (sent to field separately) Specifications: () 81/2" x 11" () 81/2" x 14" Attachments: Created by: Mitch Steinhoff Date/Time: 05/23/2000 02:34 PM Edited by: Mitch Steinhoff Date/Time: 06/12/2000 12:06 PM Mark Jackson 06/12/2000 11:02 AM Mitch Steinhoff 06/09/2000 10:07 AM Mitch Steinhoff 06/09/2000 09:50 AM Mitch Steinhoff . 06/08/2000 10:23 AM http: / /pd. partnersonline. com/ foms. nsf/ cicidc4f3.../ e635586abbcf89f8852568e80066022f ?OpenDocumen 6/12/00 A007216: Washington Square M -58 Page 3 of 3 A007216e.pdf A007216 A.pdf http: / /pd .partnersonline.com /foms.nsf /c1 c1 dc4f3.../ e635586abbcf89f8852568e80066022f ?OpenDocumen 6/12/00 J : ■ i ,'. / V < I I ; I / .. 6 ! 6 , .„ r Li.) ..z) . „, ,„ ,, „. . • C) " I i 0 a I: e ;___.; I I I `• , • I I I 4 BO+ i • 4 ,//' ,,i. • • I I TYPICAL AT SALES FLOOR © . I i i 1 0,©0 ,- i . , i i o©4 • . .I; ;I. I � � I li I ,, i I li' 4ill 9 e S ' e.4 9M s< 9 ...i ¢ 1 I I R 9 0© ) o ° =;1 I I 0 i i lI9 i ; , ;I I; ; 4p ■ I • I y � y r I I: o ©�� o©� !: . I I ! o D . % I ! ! E ! i i A i 4 �i . s s - ' ' s s - T.. • r-.�._ Ir, I • I I I i I I I I O O :,,, • •. . • 7-v /„ • /4/7 , A „ i , A i • i i SPACE I MERVYN's > 4*. � o •• 4 I i i i i i I I i PORTION OF SHEET DIA i I , FOM: A007216 TERRY WOBKEN DM STORE: WASH. SQ. OR DEMOLITION PLAN , M- 058 Q ©0=rullNE@4 ONE HUNDRED AND TWENTY FIRST AVENUE NORTH VI6" = 1'_O" MINNEAPOLIS MINNESOTA (612) 339 -0313 - PORTION OF SHEET DIA TERRY WOBKEN MP121 F °m: A007216 QQ @NEECV STORE: WASH. SQ. ONE FR D AND STAV AVENUE NORTH M- 058 MINNEAPOLIS MINNESOTA (612) 339 -0313 HARDWARE O EXISTING CEILING GRID AND TILES TO REMAIN. CLEAN, REPAIR, AND O REMOVE REPLACE TILES /GRID AS REQUIRED. NEW TILE /GRID TO MATCH REMOVE :::::::::::::: <9› EXISTING GYP BD REMOVE EXISTING ACT CEILING TILES AND GRID. PREPARE AREA FOR NEW CEILING CONSTRUCTION •: REMOVE HEAD. REMOVE EXISTING GYP BD CEILING AND ASSOCIATED FRAMING. • REMOVE VERIFY USE, CONFIGURATION, OF EXISTING >SOCIATED GRID AND ACT. REFER TO SHEET A3 AND A3A REMOVE • REMOVE >SOCIATED REMOVE PYRAMID SOFFIT LIGHTS - PREPARE AREA • FOR NEW LAY IN CEILING CONSTRUCTION AND LIGHTS. A007134 9O SAVE E> RE -USE BD, PLYWOOD, • VERIFY USE, CONFIGURATION, OF EXISTING CJ AND RE( JEW DOOR GRID AND ACT TO MATCH EXISTING ADJACENT • ! REMOVE STOCKROOM. MODIFY EXISTING GRID AS REQUIRED aoo72�6 :RIFY WITH ' 4, REMOVE Z REMOVE . COLUMN >SOCIATED O REMOVE EXISTING COUNTER /CABINET. COORDINATE W/ & REMOVE INDICATED ELECTRICAL FOR RELOCATION OF EXISTING EQUIPMENT. 4' DOORS/ ABOVE. T AND . REMOVE EXISTING CABINET. RELOCA JLE TO EXT 9 O WITH GL O NOT USED REMOVE / J �JV$ 20, . REMOVE OO :RING - REMOVE EXISTING TOILET PARTITIONS, GRAB BARS AND ` / BULKHEi DISPENSERS. /( REMOVE A REMOVE EXISTING LAVITORY AND WATER HEATER AND ASSOCIATED ` FOR NEI PLUMBING. REFER MECHANICAL AND ELECTRICAL FOR NEW WATER E. HEATER TO BE LOCATED ABOVE ROOM 121, JANITOR. - . ASE. PREPARE NOT USED /����� REMOVE EXISTING LAVITORY /COUNTER. * SEE EXT RE f'Is 0 NOT USED 0 II SAVE AL RE -USE 10 ® ® 14 PORTION OF SHEET DA TERRY WOBKEN F°": A007216 QQCN L STORE: WAS SQ. ONE FRST HUNDRED NUE NORTH M— 058 MINNEAPOLIS MINNESOTA (612) 339 -0313 CLEAN, REPAIR, AND O REMOVE EXISTING FITTING ROOM FIXTURES. SAVE FOR RE -USE. ARID TO MATCH REMOVE EXISTING SLATWALL. PREPARE WALL FOR PREPARE AREA GYP BD SURFACE. • : REMOVE EXISTING EWC. IATED FRAMING. 4 REMOVE EXISTING VINYL WALL COVERING. 9 REMOVE EXISTING CASH WRAP FIXTURES. 2 9 REMOVE EXISTING T -WALL FIXTURE :A A007134 O SAVE EXISTING FIRE EXTINGUISHERS AND SIGNAGE FOR LIGHTS. RE -USE AND RELOCATION -SEE SHEET Al FOR NEW LOCATIONS AND REQUIREMENTS. REMOVE EXISTING FOCAL FIXTURE .'ED A007216 4 T e REMOVE EXISTING SECURITY PORT /� /� / / / / / / / / /// `` 4 RE FOR NEW COLUMN COVER, AND PREPARE aTE W/ REMOVE EXISTING DISPLAY AREA. TO INCLUDE PARTITIONS JIPMENT. DOORS /HARDWARE, RAISED PLATFORM, AND CEILING SYSTEM ABOVE. EXTERIOR STOREFRONT GLAZING /FRAME TO REMAIN. RELOCATE EXISTING DOOR SECURITY SYSTEM AND RELOCATE TO EXTERIOR GLAZING. REVISE DOOR CONTACT TYPE SWCH /2\ 07 O WITH GLASS SENSOR TYPE SYSTEM AS REQUIRED. REMOVE EXISTING SALON EQUIPMENT. . REMOHEAD EXISTNG ABOVE FULL HEIGHT PATCH AS REQUIRED FRAME. PAINTING. S AND I - REMOVE EXISTING GLASS RAIL, BASE AND TOP RAIL. PREPARE A 2 AND ASSOCIATED 9� FOR NEW GLASS RAIL DETAIL. A007 FOR NEW WATER 'OR. ;AMA:AIWA Al 41> SEE EXTERIOR SIGNAGE GENERAL NOTES FOR MORE INFORMATION. . Ar II SAVE ALL ACCESSIBLE SIGNAGE AND SAVE FOR RE -USE AND RELOCATION ( i3 ' ) ( T y 4 N' u . u ' +--1 ' MECHANICAL ' LIKUL 215 I O ;L ®o a �' � z6. i � N 213 i a i v I! 251D I i ' i I 43' -0" ! N ! MECHANICAL MECHANICAL i I i251C I i O 7, 251A;1 COUNTERS MECHANICAL I I I 251B! ! I ! ! A I 1 I I v /^ <P4XFI G 1 ST SERVICE ��� © SALES I 200 I 20 TY , -r -. CHECKOUT s `, FIXTURES i 1 : � I I ` :J - ! - `I `, ' CIRCULAT - - 1 II 1 12141 I 1 i I r - i L TOP OAF SLAB ELEVAT1oN OPEN c -! I I (T /0 ;SLAB ) = 100' -0° i --,. -- - I _ I , 0 3 -1 � EXISTING i _ I I ! r i i I � .. I I � I O I e, 4 „ - ! J I I I I A007216 0 10" 0 T YP i 2 • • 1 `, A007134 1 • 1 `, AOi l ,, 1 I � - i i — ALIGN WALKS a 1 a I zz6 i I I <P4XFI ; S TOCK 1 1 226 I I I I TERRY WOBKEN 1 ONE HUNDRED AND TWENTY ! ! I PI i FIRST AVENUE NORTH i AS REOI MINNEAPOLIS MINNESOTA TO MAT 1 UPPER FLOOR PLAN (612)339 -0313 SALES F COLUMN' AlA V16" =r--0" 4 -THUS i i - Zvi Yv i I ; ; i i I FI> i i i i ATTACH TOP RAIL PER ; AS REQUIRED-SIZE � 8 ; ; Q EACH MFR SPECS - TYPICAL TO MATCH EXISTING CORNER COLUMN SALES FLOOR COLUMN I S - TYPICAL' i t I I EC) } 5' -0" + EO • EO • EO • i TOP RAIL • 4 -TH D - - - - - -- -- - - - - - - - - - - - - - - - - - - - - - - - -_- - - - -- - ----------- - - - - -- - -- 0 ; 0 w ``' i GLASS PANEL • - _ . ; i ; - GLASS RAIL in _� '- POLISHED EDGE b 411 OPEN ° , / MIN in I ` k BASE GLASS PANEL • � ____��_- �_ — I / JOINT SEE O �� ■ o �Y E i n ; ; .— -; ;_ ; I MPLY �' ' ` � PANEL JOINT 399 .—_ i - A 0 i 0 NTS 0 7 . -\- w ; w E0 EO 1 5' -0" i EO i • • I PROVIDE SILICONE STRUCTURAL E0) ' ADHESIVE, DOW CORNING 995 OR r GE SSG4000 OR APPROVED EQUAL. - A007216 TYPICAL AT ESCALATOR (4 -THUS) CTION 5 GLASS RAILING PLAN /I\ -Kr = ��_��� 1 12 " =1' -0" AlA WHERE INDICATED TERRY WOBKEN ONE HUNDRED AND TWENTY FIRST AVENUE NORTH MINNEAPOLIS MINNESOTA (612) 339 -0313 PORTION OF SHEET A2A TERRY WOBKEN F": A007216 AQCROQCC4 EM STORE: WASH SQ. ONE HUN VE AND TWENTY M- 058 MINNEAPOLIS MINNESOTA (612) 339 -0313 WALL FINISH NOTES BLOCI •••NOTE: ALL SALES FLOOR WALLS O lO SKINWALL WALL COVERING NOT COVERED W /SKINWALL, FIXTURES A OR WALL COVERING TO BE PAINTED, O O. GONDOLA SHELVING FIXTURES - IPS-I, C -I REFER TO ROOM FINISH PAINT WALL NOT COVERED WITH SCHEDULE SHEET A10 FOR ADDITIONAL FIXTURE IPS -I. C -I- EXTEND PAINT ROOM FINISH INFORMATION 6° MIN BEHIND ALL FIXTURES PAINT GYP BD WALL O7 20 SPECIALTY FIXTURE - IPS -I, C -I DOCKERS, LEE, HAGGAR, LEVI'S O EIFS FINISH, EFS -I, COLOR TO GYP BD SURROUNDING DOOR O B FRAME TO RECEIVE PAINT- MATCH MALL DECOR (OFF- WHITE) IPS -I, C -I, SEE -UNO0 (EXTERIOR): PAINT EFS -I. COLOR TO 20 MATCH BENJANMIN MOORE tt964 -AT NEW C SIGN BACKGROUND.VERIFY COLOR REQUIREMENTS WITH OSR /PROJECT O GYP BD SURROUNDING DOOR ARCHITECT. FRAME TO RECEIVE PAINT - IPS-I, C -2, SEE 20 10 REMOVE WALL COVERING, PREP WALLS, PROVIDE AI6 WC -I OR PAINT IPS -I, C- I- MERVYN'S OSR TO VERIFY WHICH MOTHOD. O WALL TO RECEIVE WC -I 5 A007216 4 A00708 i - i - - - - - I 250 , - \// I t. 8' i �� � - ■ 6. C I • i PT -I .N r . . . T -I � J 1 \ 1 1 I Ln A X ° A §I-D-E-§ -- - f t - - - - - -- - - - --- - i I - I-• i I illop .. I I I' 400708 OPEN I I I I C . 1111 � CPT-1 , -r1 L t Ilk i AI6A I O -< I I I e i - 4 SIDES O iD 0 T P . 0 4 SIDES " CPT -1 < C T -I El � I I I 5 0 17'-8" �� 4001216 I I CPT -I 8 7' -II' i C 6 © ; C 6 / X © Y--- i ! . i J _........____________ ___ I I I 1 226 i i I I i• i i i i i i i i i PORTION OF SHEET 424 TERRY WO iKEN F °M: A007216 Al2C11:004C 4 Eli] STORE: WASH. SQ. ONE HUNDRED N FIRST AVEN ENORTH • M- 058 MINNEAPOLIS MINNESOTA (612) 339 -0313 ND BLOCKING PLAN 1/16" =1' -0" • tAI I IN I)I1IU I U I(tMAIN -LLtAN AJ L I REQUIRED. REPLACE EXISTING CEILING TILES WITH NEW. 2 EXISTING GYP BD CEILING PAINT IPS -2, C -I. 3 PROVIDE NEW 2X4 CEILING GRID AND NEW 2X4 CEILING TILE. CEILING GRID AND TILE TO MATCH - - - - -- - -- - - - - - -- - -- EXISTING GRID AND TILE. COORDINATE WITH ELECTRICAL AND MECHANICAL. SEEgli FOR SPLAY BRACING DETAIL. WV PROVIDE NEW 2X2 CEILING GRID AND NEW 2X2 34 CEILING TILE. CEILING GRID AND TILE TO MATCH 5 EXISTING GRID AND TILE. COORDINATE WITH A007216 ELECTRICAL . SEE © FOR SPLAY BRACING DETAIL. 4 EXISTING GYP BD BULKHEAD PAINT IPS -I, C -I. 5 REMOVE EXISTING ACT AND GRID AS I- REQUIRED FOR NEW WALL CONSTRUCTION o 2 so u 0 r, 6 PATCH NEW 2X4 CEILING GRID AND NEW 2X4 w 00 00 CEILING TILE. CEILING GRID AND TILE TO MATCH a ¢ a EXISTING GRID AND TILE AS REQUIRED. SEE © FOR SPLAY BRACING DETAIL. 0 0 0 w 0 M 0 a- 7 V ERIFY EXISTING GRID IS CONTINUATION OF CO SALES FLOORS GRID. °, PROVIDE 3 OR 6 AS REQUIRED. Q o 0 0 N O O 0 L I � aI I n N M 'O 8 NEW GYP BD CEILING PAINT IPS -I, C -I. o 0 A007216 5 9 NEW GYP BD BULKHEAD PAINT IPS -I, C -I. B N , D m m w N L � 3 L 0 W K 0 F- PORTION OF SHEET A3A TERRY WOBKEN 0 ) FOM: A007216 AQC���ECU z 1 EEO STORE: WASH. SQ. ONE HUNDRED AND TWENTY W I FIRST AVENUE NORTH o (� M— 058 MINNEAPOLIS MINNESOTA - - - - -- - -- (612)339 -0313 2 1 i • ii i' . . ^ I I 2 C y v c ` ro e F 11 ° I I I 1 1 ° I I I ° r u, , O o - i i i 1 ■ 1 NN 111,•);,2,k f ': r i I I I �---- .1'I---- L- - - Z ._ ---- -- -- .- -- .-- -- -- -- -- -- ._.,k_. - -- - - -- ---- . _._. F] -._._. _..r.i. I -1 � U Ir ° _._. _._._. ) Ff– .Lip- - -- _T;_I_ I c e I l o �� I I° II I� __ _ o �a VL JI i 1 1' 6 G!. ' �S ■I I■If1� INN 6 < i 1IbId - • ,- • Q e 0 -� 1111 : ®r::::1 • _ OII O 11 I I R 1 I I G f I K]I I (] I I IC J I I G U ■. ■ ■ >�1i1I■� ■■.■ j U ' j ■ ■ ■ ■�RI�II ■ ■ ■ ■ ■ 1 • u EIL : I.a■■'"' 1111311•101111E2 ; 9 gill H u r : ::: :1.:::11:11 a :_ to i 1 • I ° 11 _. _. _._._. _. Z $ . --- :® ❑ •-. ---- _ I. d�C� a N y �I ��I --O'- - -- 1i 1■ . I I l Ji1/� ■I ■mumm1■i111 - - I. 1 77 I I G n i • ri lirgliMil INN 11 t I : :ii i :i iii :i :�1 ° II I I ' 11 O O • I I • ! IIIIIIIIIIII I O a 1 0 g `` KA i e I ' A r _... w_ X1111_I y l� • ° I I I I 0 11! UO I ll ! 0 0 0 II 0 0 0 0 E0 c i I I 226 I I I I I I I I I I I I I I I I I I I I I SALES FLOOR - TYPICAL TERRY WOBKEN AQca04EC4 I REFLECTED CEILING PLAN ONE HUNDRED AND TWENTY MINNEAPOLIS MINNESOTA A3A UPPER FLOOR 146" =1' —O" (612) 339 -0313 I . 1 TERRY WOBKEN • Q° ©WOVEgif G TOP RAILING: BLUMCRAFT 344 -S PROVIDE END CAPS, OR APPROVED EQUAL. PAINT T353 -GRO6 SILVER (30% GLOSS), ONE HUNDRED AND TWENTY POWDER COAT AS MFR BY CARDINAL FIRST AVENUE NORTH MINNEAPOLIS MINNESOTA (612) 339 -0313 ; 1/2THICK, CLASS 2, ASTM C1048, TYPE I, q3 QUALITY, i, GRADE B, HORIZONTALLY TEMPERED, CLEAR FLOAT GLASS v EXPANSION CEMENT 'ROCKITE' -Y— MOUNTING BRACKET BASE: BLUMCRAFT RG200 OR OR APPROVED EQUAL. —1/— APPROVED EQUAL. PAINT T353-GRO6 SILVER (30% GLOSS), i POWDER COAT AS MFR BY CARDINAL. i i 21 /2 ° \ CT -I, TYPICAL EACH SIDE +l ♦ SCHLUTER DILEX -BWA, COLOR HB- TYPICAL OF BASE I i T EACH SIDE 'cc' -'.'..-------- ;;.. i Q • I' -0 °. +,; - EXISTING METAL DECK ( ..:::;,:: Al CONCRETE COMPOSITE UPPER LEVEL ------ - - - - -- 72 . j��� S /� , � � TRIM ARD , / /// / //je,/ 5 �� PAINT IPS -I, C -I A0o7 1%/!11 /�w CONTRACTOR �u,,,,,,, i ALTERNATE: WC -I, =NOTE: VERIFY I' -O° DIMENSION. DIMENSION MAY VAEItY /it IF REQUIRED DUE TO DUE TO MOUNTING REQUIRMENTS AT (4) CORNER COLUMNS EXISTING CONDITIONS AND TOP RAIL CONNECTION. REVISE AS REQUIRED. HILTI KB II 304SS CI4 -4 COUNTERSUNK KWIK BOLT D XX OC 25 GUARDRAIL @ ESCALATOR A16A 3 ". y -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- KEY NOTES CONNECT NEW 2'x2' FIXTURES TO NEW "BAS" CONTROLLED LIGHTING CIRCUIT. EXISTING LIGHTING WAS REMOVED PER SHEET DE1A. © RELOCATE EXISTING FIXTURES AS INDICATED. EXTEND EXISTING CIRCUITRY. ['REPLACE EXISTING RESROOM LIGHTING WITH NEW C1 FIXTURES. EXTEND CIRCUITRY AS REQUIRED. 4 REINSTALL 'STRIP' FIXTURES REMOVED PER SHEET E1A. EXTEND CIRCUITRY AND MOTION SENSORS AS REQUIRED. VERIFY FINAL LOCATION WITH MERVYN'' CSR. REWORK LIGHTING AS REQUIRED TO ACCOMODATE NEW LAYOUT. 6 EC SHALL I NSTALL (3) 4' FLOURESCENT, 120 VOLT STRIP FIXTURES REMOVED FROM DEMOLISHED STOCKROOMS. INSTALL SWITCH AT NEAREST ROOM EXIT FOR CONTROL OF FIXTURES. CONNECT FIXTURES 20 AMP - 1P SPARE CIRCUIT, PANEL ' PJ' . FIXTURES SHALL BE MOUNTED JUST BELOW JOIST SPACE. INSTALL FIXTURES AS DIRECTED BY CSR. FlREFER TO GENERAL NOTE D. 8 CONNECT TO NEW EXIT SIGNAGE TO EXISTING of I 9 INSTALL NEW 20A -2P BREAKER IN PANEL 'B'. REMOVE EXISTING SPARE CIRCUIT BREAKERS AS REQUIRED.CONNECT NEW AESCALATOR LIGHTING TO NEW BREAKER. MOUNT NEW 20A -2P CONTACTOR W/ ENCLOSURE ADJACENT TO PANEL 'B' PARALLEL CONTROL WIRING FROM EXISTING ESCALATOR LIGHTING CONTROL CIRCUIT TO NEW CONTRACTOR. PARTIAL SHEET E2A l uRJaC ELECTtiIC. INC. mm: A007216 L ARJ AC INDIANAPOLIS) 5. 42 -1IN 4 369 62 0 TEL E. 1317 0 PROTO:M -05 CFG: T AX 1317) 549 -0926 STORE WASHINGTON SO. ! i i i i i , I I I I $ I I 1 I I I 1 I I % .. • • 1 ” - - $ 0 I . • 0 $ 0 $ $ $ I 4 4 9 PANEL ' B' . . . 1 UPPER LEVEL LIGHTING PLAN E2A PARTIAL SHEET E2A _._-- LARJAC ELECTRIC. INC. 6131 EAST 30TH. STREET F°M: A007216 LARJAC INDIANAPOLIS. IN. 46219 TELE. (317) 542-1369 ID mac): M -058 CFG: sW1•1111=1/ 1. /MIMIV4 ) c c TRIG \ FAX 13171 549-0926 STORE WASHINGTON SO. , . i___; ; i i i i 1..j. , i i i i i i i i i I I I I O 1 O I I i i i r 1; I I 2 ! ! ! I I 2 . 5 LA-007216 _ ! _ , 35,37 , 3 1 37111 ■■■ ■ ■II III ; ! 2 1 -- - - ..■ ■.■ , ■ ■Ilil ■■■ 3 5 a P 7 1 G 117 ! -- 35371 ! � III III • ■■■ ■■■ 1 i ■■■ 3 5, 3 7 i O 1 i i i G [ii • -- i 3 ,;pl ■■Il i ;_ -; _ -; _ 12 I __; .- 3 5 3 7 ■■■ IIII■ ■■■ ■■■ I, ; .0 ' ; In in III II ,I 5 -- 1 -- -- 1 ! , ( I 1 i 3 5 3 7 ■■■ ��ll■ ■■■ •■■ 3 3 7 -- IN i 1 i -- 1 • J I I d i . - - - -- i - — 35,37 -- L -- i i 2 I 4 I , i I i i i i i i Q Y 1 1, 5 i i; i i i i PARTIAL SHEET E2A LARJAC ELECTRIC. INC. 6131 EAST 30TH. STREET FOM: A007216 L ARJ AC I NDIANAPOLIS. IN. 46219 TELE. 13171 542 -1369 0 PROTO:M - 058 CFG: ( V FAX ( 317 l 549 -0926 CTR IC STORE WASHINGTON SO. BUS AMP MAN O.C. MAZE LOCATION MATING SUPPLED FROM VOLTAGE SIZE DEVICE B 2ND FLOOR SURFACE 208/120 VOLT 3PHASE 4WIRE 225A w/GROUND BUS - INTEGRATED EOUIPMENT SHORT CIRCUIT CURRENT RATING UER1- 10.000 AMPS CONNECTED TYPE I BRANCH CIRCUIT BRANCH TYPE I CONNECTED LOAD OTT. CF C/8 AND C/B OTT. OF LOAD DESCRPTION (RVA) LOAD AMP /POLE PHASE LW /POLE LOAD atVm DESCRPTION LTS WASH /DRYER AREA 43 20/ I IA 2A 20/ I 0.5 LIGHTING LTS SINK AREA LB 20/ I 38 48 20/ I 0.2 LIGHTING ITS SINK AREA L5 20/ I SC 6C 20/ I 0.5 LIGHTING LTS 1ST 1/2RM 0.5 20/ I TA 8A 20/ 1 0.3 RECEPTACLES LTS 1ST 1/2RM 0.5 20/ I 98 08 20/ I 0.5 RECEPTACLES LIGHTING 0.9 20/ I 11C 12C 20/ 1 0.2 RECEPTACLES RECEPTACLES 0.5 20/ I 13A 14A 20/ I 0.0 RECEPTACLES RECEPTACLES 0.7 20/ I 158 16E1 20/ I 0.4 RECEPTACLES RECEPTACLES L I 20/ I ITC 18C 20/ I I.1 WASHER DRYER 0.5 30/ 2 19A 20A 30/ 2 0.7 DRYER DRYER 0.5 218 22B 0.7 DRYER RECEPTACLES 0.0 20/ 1 23C 24C 20/ I 12 RECEPTACLES RECEPTACLES 0.4 20/ I 25A 26A 20/ I 1.2 RECEPTACLES N ADA DOOR 02 20/ I 278 28B 20/ I 0.0 SPARE N CHRISTMAS PP 02 20/ I 29C 30C 20/ I 0.0 SPARE RECEPTACLES 0.4 20/ I 31A 32A 20/ I 0.0 SPARE • I 338 34B 20/ I 0.0 SPARE N. ESCALATOR LTG. 0.0 20/ 2 35C 36C 20/ I 0.2 EXISTING CAT. N. ESCALATOR LTG. 0 . 0 3TA 38A 20/ I 0.2 LIGHTING CONTROL CAT. '•' i I 398 408 20/ I 0.2 N. WALL PLUGS 5 SPARE 20/ I 41C 42C 20/ I 0.2 N. WALL PLUGS A007216 TOTAL 6.5/A 6.30B 7.10C 19.9 KVS 55.2 AMPS (WAS 54.0 AMPS) 1 PARTIAL SHEET E8 LARJAC ELECTRIC. INC. 6131 EAST 30TH. STREET FOM: AOO7216 LARJAC INDIANAPOLIS. IN. 46219 TELE. ( 317 ) 542 -1369 0 PROTO: -OSH CFG: (lf. FAX (317) 549 -0926 STORE WASHINGTON SO. A007085: Washington Sq. M -58 -Plan Check Page 1 of 3 f. Edit_this Draft 3 44 f 71O c'c2 — 00 e, gas) DHC Property Development Field Order Modification FOM #: A007085 - - - Subject: Washington Sq. M -58 -Plan Check Status: Complete for Issue Produced by: Mitch Steinhoff Input required - Architectural Yes Complete Structural No Mechanical No Electrical Yes Complete Specifications Yes Complete Store Planning No Company: Mervyn's Reason for issue: Requested by: Mitch Steinhoff CMT Change item #: - N/A - Do not FOM: Issue date: 8 March 2000 I FOM'd Prototypes: 11 FOM'd Cycles: II FOM'd Stores: M296 IlCycle 2 2000 I M - 58 Configuration: DHC construction to modify the following in the field: Comments: RSP FOM# 1 Architectural: Sheet Al -Lower Level Floor Plan (Full sheet reissued) -Add exit signs; Add Exit Sign General Notes; Revise Accessible Checkstand General Notes. Sheet Al A -Upper Level Floor Plan (Full sheet reissued) -Add exit signs; Add Exit Sign General Notes; Revise Accessible Checkstand General Notes; Revise Partition between 'Void Space' and Mervyn's; Add Corridors 253 and 254; Add Doors 200.1, 200.2, http:// pd. partnersonline. com/ FOMS. nsf/.../ 43f9c0f72d05f21e85256893007b76f4 ?OpenDocumen 3/8/00 A007085: Washington Sq. M -58 -Plan Check Page 2 of 3 /j 200.3, 200.4 and 200.5; Add General Note 'Q'; Add Details 2/A 1 A, 3/A 1 A and 4/A 1 A. Sheet A2 -Lower Level Floor Finish & Blocking Plan (Full sheet reissued) - Revise note at mall entry; Revise Wall Finish Note '8'; Add Wall Finish Note '9'. Sheet A2A -Upper Level Floor Finish & Blocking Plan (Full sheet reissued) -Add Wall Finish Note '10'; Add wall finish refernece at escalator opening; Revise transition note at room 213. Sheet A3 -Lower Level Reflected Ceiling Plan (Full sheet reissued) -Add General Note 'G'; Revise Reflected Ceiling Plan Keynote '1'. Sheet A3A -Upper Level Reflected Ceiling Plan (Full sheet reissued) -Add General Note 'G'; Revise Reflected Ceiling Plan Keynote '1'. Sheet A10 -Room Finish Schedule and Partition Types (Full sheet reissued) - Revise partition types P2 and P4; Add Room Finish Notes '15' and '16'; Add Circulation 253 and 254; Revise rooms 100, 102, 122, 200, 213, 214, 218, 219, 222, 233, 235 and 236. Sheet Al 1 -Door Schedule & Details (Full sheet reissued) -Add FG door type; Add Frame type 4; Revise Opening Schedule Note '18'; Add Opening Schedule Notes '20' and '21'; Add note (top) to Door Schedule; Revise Notes' at doors 100, 101, 101.1, 101.2, 101.3, 101.4, 101.5, 101.6, and 101.7; Revise door 200; Add Doors 200.1, 200.2, 200.3, 200.4 and 200.5; Revise Doors 201 and 201.1; Revise 'Notes' at doors 204, 204.1, 205, 206, 206.1 and 211. Sheet A 16-Interior Finish Details (Full sheet reissued) - Revised Detail 5/A16. Structural: N/A Mechanical: N/A Electrical: Sheet E2A, added exit fixtures to egress cooridors per plan check requirement, revised light fixtures locations over escalator; sheet E9, added fixture type NI to fixture schedule. Specifications: wasA00785.pdf - Revise Specification Sections; 00030 -Table of Contents 08700 - Hardware 08800 - Glazing Add Specification Section; - 08460 - Automatic Swinging Entrance Doors wasA08460.pdf - New Section Added -See above. http: / /pd. partnersonl ine. com / FOMS. nsf/.../ 43f9c0f72d05f21e85256893007b76f4 ?OpenDocumen 3/8/00 A007085: Washington Sq. M -58 -Plan Check Page 3 of 3 Summary of Attached Drawings: Architectural: () 81/2" x 11" () 81/2" x 14" (9) full size sheet (sent to field separately) Structural: 0 81/2" x 11" () 81/2" x 14" () full size sheet (sent to field separately) Mechanical: () 81/2" x 11" () 81/2" x 14" () full size sheet (sent to field separately) Electrical: () 81/2" x 11" ()81/2 "x14" (2) full size sheet (sent to field separately) Specifications: () 81/2" x 11" 0 81/2" x 14" Attachments: • Created by: Mitch Steinhoff Date/Time: 02/28/2000 05:28 PM Edited by: Mitch Steinhoff Date /Time: 03/08/2000 04:54 PM Mitch Steinhoff 03/08/2000 04:53 PM Mitch Steinhoff 03/08/2000 03:38 PM Mitch Steinhoff 03/08/2000 03:23 PM Mitch Steinhoff 03/08/2000 03:22 PM T wasA007085.pdf was08460_pdf http:// pd. partnersonline. com /FOMS.nsf /.../43f9c0f72d05f21 e85256893007b76f4 ?OpenDocumen 3/8/00 ti, SPECIFICATION REVISIONS FOR FOM No. A007085 DOCUMENT 00030 - TABLE OF CONTENTS GROUP 21: Under Division 8 — Doors and Windows, Add New EXTERIOR ALUMINUM ENTRY, AUTOMATIC Section as follows: SWINGING, PAIR 08460 Automatic Swinging Entrance Doors Pivots Specified in Section 08460 Closers /operators Specified in Section 08460 Finger protectors Specified in Section 08460 ' 1 deadlock MS1851SWx1- 1/8 "BS x .4089.LHR SECTION 08460 — AUTOMATIC SWINGING leaf ENTANCE DOORS 1 armored strike Besam 50 -03 -107 1 cylinder 1E76 (Note Al) 1 threshold bolt 4015 New Section Added with this FOM 1 header bolt 4085 1 dustproof strike 487/489 2 push bars 1081 w/o back plates (Note A2) 4 kickplates per spec • SECTION 08700 — HARDWARE 2 sweeeeps ps 3 32323 6A 2 sw Article 3.3 Hardware Schedule — General, Add new GROUP 21A: Groups as follows: VESTIBULE ALUMINUM ENTRY, AUTOMATIC GROUP 1D: SWINGING, PAIR Pivots Specified in Section 08460 INTERIOR, ALARMED EXIT DEVICE, EXIT ONLY WITH Closers /operators Specified in Section 08460 KEYED FIRE DEPARTMENT ACCESS FROM EXTERIOR Finger protectors Specified in Section 08460 OR STAIR SIDE, PAIR, RATED 2 push bars 1081 w/o back plates (Note A2) 4 kickplates per spec 1 threshold BA14 - 1/4" x 4 -1/2" beveled EXIT ONLY DOORS INTO STAIR 3 pair butts FBB199 4 -1/2 x 4 -1/2 NRP 1 exit device SS9947- 990NL -F 1 exit device SS9975 -EO -F SECTION 08800 — GLAZING 3 cylinders 1 E74 1 power supply PS861 Article 1.1 Summary; Add new paragraph as follows: 2 magnetic switches MS764 1 horn L1910F 6. Tempered glass for automatic entrance 2 power transfers EPT -10 doors, aluminum entrances and storefronts. 1 coordinator 500 series 2 closers 4041 Cush -N -Stop . 1 threshold S483AV 1 sign "ALARM WILL SOUND WHEN END OF SPECIFICATION REVISIONS DOOR OPENS" GROUP 8: • E D AR C , OFFICE LOCK, WITH CLOSER, SINGLE q,, TERRY OBKEN RATED CORRIDOR TO OFFICE "•. 1 -1/2 pair butts F179 4 -1/2 x 4 -1/2 ® MINNE ' POLIS, MN 1 lockset 93K- 7AB15D L.R 12 . 1 closer 4041 1 stop 60W �� QF ogl'C'' 03/08/00 Page - 1 mervyn's California WASHINGTON SQUARE - PORTLAND OR (ISSUED WITH FOM A007085) M -058 SECTION 08460 C. Design system to operate, hold open and close AUTOMATIC SWINGING ENTRANCE doors under design wind pressure and suction DOORS loads specified in Section 08400. D. Provide for thermal expansion and. contraction PART 1 - GENERAL of door and frame units, transmitted to operating equipment. 1.1 SUMMARY E. Provide for dimensional distortion of A. Section Includes: components during operation. 1. Packaged electric automatic swing doors F. Eliminate the possibility of water accumulating and operating equipment for existing or and freezing in door power units. new opening. G. Provide for opening and closing operation of 2. Matless electronic sensing control system. doors in the event of power failure. 3. Automatic aluminum door hardware and accessories. H. Provide emergency breakaway feature, with automatic electrical reset, in the direction of 1.2 RELATED ITEMS egress on inswing and outswing doors. 1. Stanly Doors: Door break -a -way features A. Section 08400 - Entrances and Storefronts; for shall comply with all local and state codes manual doors. with regard to the force required to set B. Section 08700 - Hardware; for specified doors in motion and to continue moving hardware. door to full open position. C. Section 08800 - Glazing. I. Operating Temperature Range: -20 to 140 degrees F ( -7 to 60 degrees C) ambient. D. Division 16 - Electrical; for power wiring and conduit to operator. J. Provide fully adjustable operators for opening and closing speeds, checking speeds, and 1.3 SYSTEM DESCRIPTION hold - open time. A. System includes aluminum and non - aluminum 1.5 QUALITY ASSURANCE materials, accessories (except glazing materials and accessories), and finishes for complete A. Comply with applicable requirements of ANSI installation of automatic aluminum entrance A156.10 and local applicable codes. doors including, but not limited to the B. Installer Qualifications: Engage an installer following: who is an authorized representative of the 1. Aluminum sections as specified in Section automatic entrance door manufacturer for both 08400. installation and maintenance of type of units 2. Reinforcing. specified. Installer shall have not less than 2 3. Fasteners. years experience in the installation and service 4. Operating equipment. of automatic entrance doors of the same 5. Hardware: All materials installed within, or manufacturer. attached to, manual aluminum entrances and storefront as specified in Section C. Regulatory Requirements: Conform to 08700, excluding cylinders. applicable codes for automatic release of control drive unit to permit manual opening of B. Adjacent jamb framing, transom framing, and doors. thresholds are work of Section 08400. 1.4 PERFORMANCE 1.6 REFERENCES A. American Society for Testing and Materials, A. Automatic door equipment to accommodate (ASTM): heavy pedestrian traffic, and weight of doors. 1. ASTM D2000, "Classification System for B. Operator Equipment: UL 325 listed. Rubber Products in Automotive Applications ". AUTOMATIC SWINGING ENTRANCE DOORS 08460 - 1 ' WASHINGTON SQUARE - PORTLAND OR (ISSUED WITH FOM A007085) M -058 mervyn's California 2. ASTM D2287, "Specification for B. Materials: Provide 2 year manufacturer's Non -Rigid Vinyl Chloride Polymer and warranty for replacement or repair of materials Copolymer Molding and Extrusion due to faulty fabrication, workmanship and Compounds ". materials. B. American National Standards Institute, C. Installation: Provide 2 year warranty for (ANSI): replacement or repair of materials due to faulty 1. ANSI A156.10, "Power Operated workmanship and installation. Pedestrian Door Standard ". D. Warranty periods as specified begin on date of C. Underwriters Laboratories, (UL): final acceptance of work. 1. UL 325, "Electric Door, Drapery, Gate, Louver, and Window Operators and PART 2 - PRODUCTS Systems ". 1.7 SUBMITTALS 2.1 MANUFACTURERS A. Comply with Section 01300, Submittals. A. Acceptable Manufacturers: 1. Besam. B. Shop Drawings: Submit shop drawings for 2. NT Dor- O- Matic. fabrication and installation of automatic 3. Stanley. entrance doors and associated components of work. Indicate anchors, joint system, 2.2 EXTRUDED AND SHEET ALUMINUM AND expansion provisions, hardware, and other FASTENERS components not included in manufacturer's standard data. A. Comply with requirements of Section 08400. C. Product Data: 2.3 STEEL FOR REINFORCING AND BRACKETS 1. Submit manufacturer's product data and standard details for automatic entrance A. Comply with requirements of Section 08400. doors, including fabrication, finishing, hardware, operators, accessories and other 2.4 FINISH components. Include roughing -in diagrams, A. Exposed aluminum surfaces of doors, operator wiring diagrams, parts lists, and housing, presence sensors and other electronic maintenance instructions and certified test components shall have type paint finish data. specified in Section 08400. 2. Furnish template, diagrams and other data 1. Swinging Entrance Doors: Match color to fabricators and installers of related finish of adjacent frames. work, as needed for coordination of automatic entrance installation. 2.5 ALUMINUM DOORS D. Certificates: Submit certification that installer A. Modify and reuse existing aluminum doors for is an authorized representative of new swing and automatic operation. manufacturer, and document experience qualifications. B. Contractor's Option to provide new aluminum doors as follows: 1.8 COORDINATION 1. Automatic Swing Doors: Provide aluminum doors to match existing doors A. Coordinate custom finishing of aluminum and products specified in Section 08400, as components with work of Section 08400, to selected for Project. Provide doors sized as assure that automatic entrance door indicated on Drawings and to fit existing components receive matching finish from same opening, and including provision for finger coating applicator and same production run. protection at pivot jambs. Prepare doors for connection to swing door operators and 1.9 WARRANTY related hardware. A. Finish: Provide finish coating applicator's standard 5 year warranty. AUTOMATIC SWINGING ENTRANCE DOORS 08460 - 2 • • mervyn's California WASHINGTON SQUARE - PORTLAND OR (ISSUED WITH FOM A007085) M -058 2.6 OPERATOR HOUSING 2. Do -O -Matic recessed "Super Nova" electronic presence sensors full width of A. Extruded aluminum sections with a minimum door; 115 volt 60 Hz/1 phase power wall thickness of 0.125 ", size as required by supply. manufacturer to enclose operator. 3. Stanley Sentrex sensor heads mounted on 2.7 PACKAGED HARDWARE each door stile, 117 volts A.C. 50/60 Hz. C. Motion Detector: A. Swinging Entrance Hardware: 1. Besam "Pathfinder ", surface mounted, 1. Pivots: As recommended by automatic self- contained radar microwave transmitter entrance manufacturer. , and receiver; 115 volt 60 Hz/1 phase a. Finish: US26D (626). power supply. 2. Finger Protectors: Manufacturers standard 2. NT Dor O Matic " Astro Scan ", surface collapsible, replaceable gaskets; either mounted, self - contained radar microwave ASTM D2000 molded neoprene, or ASTM transmitter and receiver; 115 volt 60 Hz/1 D2287 molded PVC. phase power supply. 2.8 FABRICATION 3. Stanley "Stan Ray ", surface mounted, self - contained radar microwave transmitter and A. Provide automatic entrance doors as receiver, 117 volts A.C. 50/60 Hz. prefabricated packaged units complete with D. Presence Sensor and Motion Detector control doors, door operators and controls, operator functions to work in unison. housing, door pivots, finger protectors, and accessories. Complete fabrication, assembly, E. One control switch, on- hold -off, per pair of finishing, packaged hardware applications, doors, mounted on operator housing. factory wiring, and other work before shipment F. Complete system factory assembled, pre - wired, to Project site. and factory tested. B. Comply with applicable requirements of G. Motion detector and sensor housings of Section 08400. extruded aluminum or high- impact zinc 2.9 SWINGING AUTOMATIC DOOR PACKAGES casting, with high- impact tinted acrylic lenses. A. Model and System: PART 3 - EXECUTION 1. Besam Visionpulse VP9300: Two Swingmaster self - contained overhead 3.1 PREPARATION concealed operators per pair of doors, and center hung bottom pivot swinging doors. A. Take field measurements prior to preparation 2. NT Dor -O -Matic Recessed Super Nova: of shop drawings and fabrication, to ensure Two Astro Swing No. 8663 self - contained proper fitting of work. overhead concealed operators per pair of doors, and center hung bottom pivot 3.2 INSPECTION swinging doors. 3. Stanley doors. Swing Door System: Two A. Verify that openings are ready to receive work Magic Swing self - contained overhead and opening dimensions are as indicated on concealed operators per pair of doors, and shop drawings. center hung bottom pivot swinging doors. B. Verify that power supply is available to power a. Door break -a -way features shall operated devices. comply with all local and state codes with regard to the force required to set C. Beginning of installation means acceptance of doors in motion and to continue existing conditions. moving door to full open position. 3.3 INSTALLATION B. Presence Sensor: 1. Besam S " Visionpulse" recessed mounted A. Install equipment according to shop drawings electronic presence sensors full width of and manufacturer's instructions. door; 115 volt 60 Hz/1 phase power B. Install Motion Detector at approach side of supply. header at automatic doors. AUTOMATIC SWINGING ENTRANCE DOORS 08460 - 3 • , • WASHINGTON SQUARE - PORTLAND OR (ISSUED WITH FOM A007085) M -058 mervyn's California C. Coordinate installation of components with related and adjacent work, level and plumb. D. Separate aluminum and other corrodible metal surfaces from sources of corrosion as specified in Section 08400. 3.4 ADJUSTING AND CLEANING A. Clean exposed surfaces. B. Adjust door equipment for correct function, smooth and synchronized operation, and optimum safety. After 200 cycles of operation, readjust door equipment. C. Protect automatic entrance doors until time of acceptance. Permit use of completed installation only as directed by OSR. END OF SECTION • • AUTOMATIC SWINGING ENTRANCE DOORS 08460 - 4 Jerry Wobken :A v _0 o q v p-bcio " • COMM. NO: 8199.012.00 Copy: Jane Miller- Target Corporation CLIENT: Mervyn's Bill Ferris- Target Corporation PROJECT: Washington Square, OR; M -058 Ron Pockrus, OSR Darrin Kent - Conlon SUBJECT: Plan Check Response File 4 MEMO BY: Mitch Steinhoff I - 1 A� 8 � DATE: 8 March 2000 Attention: Robert Poskin, CBO Senior Plans Examiner The following is an item -by -item response to the Plan Check Response memo received in our office 25 February 2000, for the above referenced Mervyn's Store. The response is base on items listed on the Plan Review with the response indicated in bold type. Energy Compliance Provide Oregon Non - Residential energy code forms 5a through 5c. Response: Oregon Non - Residential Energy Code Forms 5a through 5c have been completed and are attached for your use per your request. Fire Life Safety 1. Doors labeled 200 and 201.1 at entry #3 shall swing in the direction of travel. OSSC, Section 1003.3.1.5. Response: Doors 201 and 201.1 have been revised to swing in the direction of travel as shown on sheet A1A -Upper Level Floor Plan. Also, refer to Sheet All -Door Schedule. The door schedule has been revised and opening schedule note `21' has been added to clarify door swing and re- construction. (FOM A007085) 2. The second required exit that meets the required overall diagonal distance pass through what we believe is a corridor. Please confirm that this area is indeed a rated corridor with required rated doors. Response: The existing exiting from the Mervyns's sales floor exits through a corridor that passes through an existing `Target' district office space. Individuals from Terry Wobken, Architect's performed a building walk- through of the existing Mervyn's/Target district office spaces, and at that time it appeared that the existing wall/ceiling construction and doors were consistent with one -hour fire rated construction. The following information has been added to the drawings for the General Contractor to further verify construction. . Terry Wobken, AIA 120 First Avenue North, Minneapolis, Minnesota 55401 FAX 612 • 339 • 6760 TEL 612 • 339 • 0313 MEMORANDUM Plan Check Response - Washington Square, OR 8 March 2000 Page 2 Refer to Sheet A1A -Upper Level Floor Plan. General Note `Q' has been added to clarify and provide additional directions for the General Contractor to verify wall/ceiling and door construction /type for a one -hour fire rated construction. Details 2 /A1A, 3 /A1A, and 4 /A1A have been added, if the General Contractor is required to provide portions or complete one -hour construction. One -hour wall construction is to conform to UL assembly #U465, 1999 UL Directory. The General Contractor has been given the choice of full height wall construction or `tunnel' type construction. (FOM A007085) Refer to Sheet A10 -Room Schedule. Corridors 253 and 254 have been created to clarify the area in question. Room Finish Note `15' has been added to clarify this requirement. A note has been added to partition types P2 and P4, as referenced on Sheet AlA, floor plan, to clarify one -hour construction type. One -hour wall construction is to conform to UL assembly #U465, 1999 UL Directory. (FOM A007085) Refer to Sheet All -Door Schedule. Doors 200.1, 200.2, 200.3, 200.4 and 200.5 (doors in corridor -see plan) have been added to clarify requirements of 20 min rated door assemblies. Opening schedule note `20' has been added to clarify requirements of 20 min rated door assemblies. (FOM A007085) 3. The walls separating the void space from your retail space shall be one -hour rated. This requirement was part of the original approval for the mall under alternate methods of design and construction. Provide details. Response: The wall separating the void space and Mervyns's retail space has been revised to a one -hour fire rated wall construction. Detail 2 /A1A has been referenced and provided to clarify requirements of one -hour rated wall construction. A note has been added to partition types P2 and P4 on Sheet A10 -Room Finish Schedule and Partition Types, as referenced on Sheet AlA, floor plan, to clarify one -hour construction type. One -hour wall construction is to conform to UL assembly #U465, 1999 UL Directory. (FOM A007085) 4. Revised plans shall show the location of all required exit illumination as well as directional arrows. OSSC, Section 1003.2.8.4. Response: Exit signs have been added to Sheets Al -Lower Level Floor Plan and A1A- Upper Level Floor Plan to clarify exit sign requirements. Exit Sign General Notes; have been added to clarify exit sign symbols and general information. (FOM A007085) Accessibility Drawing Al - Accessible check stand height shall be 36" from finished floor. OSSC, Section 1109.23.2. Provide details. Response: Accessible Checkstand General Notes on Sheet Al and AlA have been revised from 38" to 36 ". Referenced Detail 5/A16 has been revised to clarify 36" requirement. (FOM A007085) tip Mervyn994emodel\Washington SquerePRO22800MAS.doc February 22, 2000 , 000 :'1.�''_,, Terry Wodgen CITY OF TIG� 120 First Avenue, North OREG Minneapolis, MN. 55401 RE: Mervyns's California PC# 2 -20C 9400 SW Washington Square BUP# 2000 -00048 Dear Sir: Your plans for the proposed tenant improvement have been reviewed; the following items require your attention. 4 0/), Ener Compliance (' rovide Oregon Non - Residential energy code forms 5a through 5c. Fire L Safety D y, Doors labeled 200 and 201.1 at entry #3 shall swing in the direction of travel. OSSC, Section 1003.3.1.5. V O/ The second required exit that meets the required overall diagonal distance pass through what we believe is a corridor. Please confirm that this area is indeed a rated corridor with required rated doors. �/, The walls separating the void space from your retail space shall be one -hour rated. This requirement was part of the original approval for the mall under alternate methods of design and construction. Provide etails. Revised plans shall show the location of all required exit illumination as well as directional arrows. OSSC, Section 1003.2.8.4. Accessibility rawing A 1 — Accessible check stand height shall be 36" from finished floor. OSSC, Section 1109.23.2. Provide details. Mechanical, Electrical, sprinkler, and Plumbing plans and permits are deferred submittals. Please provide two (2) sets of revised Architectural and Structural drawings. If you have questions, please call me at'639 -4171 X392. Sincerely • Ro ert Poskin, CBO Senior Plans Examiner • • 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 •