Loading...
Correspondence l6I 4 I J' � I' January 26, 2006 CITY OF TIGARD OREGON Macerich/Washington Square Rick Beason 9585 SW Washington Sq Rd Tigard, OR 97223 RE: 2 CORRIDOR RELOCATIONS - REVIEW Project Information Building Permit: BUP2006 -00058 Construction Type: lI - Tenant Name: PPR Washington Square LLC Occupancy Type: M Address: .95-SW Washington Sq. Stories: 1 4505 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004 edition; and 2004 Oregon Fire Code as amended by TVF &R. The submitted plans are approved subject to the following conditions. 4. Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. 1011.1 OSSC 5. All exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. 1008.1.8 OSSC 6. Exit signs shall be illuminated at all times and shall be provided with a second source of power that will provide 1 'h hours of illumination in case of primary power loss. 1006.3 OSSC FYI Additional exit signs may be required by the city field inspector to clearly indicate the path of egress. 7. The means of egress shall be provided with illumination of not less than 1 foot candle at the floor level anytime the building is occupied. The means of egress illumination shall be provided with a second source of power in case of primary power loss. 1006.2 OSSC 10. Deferred submittals such as Fire Alarm, Fire Sprinkler, Truss Joist Shop Drawings, etc, will • be charged a deferred submittal fee based on the valuation of the portion of the work being deferred. The minimum fee shall be $200.00. Deferred Items: None Listed 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 American with Disabilities Act (ADA): It shall be the responsibility of the Architect, Engineer, Designer, Contractor, Owner and Lessee to research the applicability of the ADA requirements for the structure. The City of Tigard reviews the plans and inspects the structure only for compliance with Chapter 11 of the OSSC, which may not include all of the requirements of the ADA Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.3.1 OSSC Premises Identification: Approved numbers or addresses shall be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. • Respectfully, Val Henzel, Senior Plans Examiner •