Specifications • . 8' 90' id . Si. i', C u ee0D3 —co3�a co N. Reliabla B ulletin 148 R ev.B a M odel F1 FR Model Fl FR Recessed 5 Quick Response Extended t Coverage Sprinklers co A complete line of UL Listed and FM Approved quick response extended coverage sprinklers for light hazard applications. 14do, / - Horizontal Sidewall Sprinklers are approved`' for installation 4" - 12" (102mm - 305mm) below the ceiling. - . Model Fl FR QREC Sprinkler Types Extended Coverage Pendent Extended Coverage Horizontal Sidewall Extended Coverage Recessed Extended • EC -8 Deflector Pendent Coverage Pendent • EC -9 Deflector Model Fl FR QREC Recessed Sprinkler Types d m„ Recessed Extended Coverage Pendent ,.: Recessed Extended Coverage Horizontal ' = —' 'a Sidewall: t r , t • EC -8 Deflector r , • EC -9 Deflector • ............. ` Approval Organizations Extended Coverage Recessed Extended r Horizontal Sidewall EC -8 Coverage Horizontal Sidewall -� 1. Underwriters Laboratories, Inc. EC -8 2. Underwriters' Laboratories of Canada 3. Factory Mutual Research Corporation 4. NYC MEA 258 -93 -E UL Listing Category _ Sprinklers, Automatic & Open , - Quick Response Extended Coverage Sprinkler UL Guide Number �t ' - . VNIV Note: Consult appropriate FM Installation Standards regarding limitations of room size, ceiling height and minimum wall fire resistance rating. Extended Coverage Recessed Extended Horizontal Sidewall EC -9 Coverage Horizontal Sidewall EC -9 Product Description Reliable Models F1FR QREC and F1FR QREC The balance of parts are made of brass, copper and Recessed Sprinklers are quick response sprinklers which beryllium nickel. combine the durability for a standard sprinkler with the The temperature rating of the sprinkler is identified by attractive low profile of a decorative sprinkler. the color of the glass bulb. The Models F1FR QREC and F1FR QREC Recessed A Ilti Automatic Sprinklers utilize a 3.0mm frangible glass bulb. pp la These sprinklers have demonstrated response times in Quick response sprinklers are used in fixed fire laboratory tests which are five times faster than standard protection systems: Wet, Dry, Deluge or Preaction. Care response sprinklers. This quick response enables these must be exercised that the orifice size, temperature sprinklers to apply water to a fire much faster than rating, deflector style and sprinkler type are in standard sprinklers of the same temperature rating. accordance with the latest published standards of the The glass bulb consists of an accurately controlled National Fire Protection Association or the approving amount of special fluid hermetically sealed inside a authority having jurisdiction. Quick response sprinklers precisely manufactured glass capsule. This glass bulb is are intended for installation as specified in NFPA 13. specially constructed to provide fast thermal response. The Reliable Automatic Sprinkler Co., Inc. • 525 North MacQuesten Parkway • Mount Vernon • New York •10552 Model Fl FR Quick Response Extended Coverage Pendent Sprinkler Deflector: EC I . Installation Wrench: Model D Sprinkler Wrench Approval Type: Quick Response Extended Coverage -Light Hazard Occupancy Installation Data "K" Factor Sprinkler Nominal Thread Sprinkler Temperature" Approval Identification Orifice Size US Metric Length Rating Organizations Number (SIN) 732" (20mm) %" NPT (R 8.0 115 (56.1 212" ) 155 °F 135°F (57( ) 1,2,3,4 84842 mm /" (15mm) ' /2" NPT (R1/2) 5.6 80 21" 135 °F (57°C) 1,2,4 R4845 (53.4mm) 155 °F (68°C) '') FM Approval of pendent sprinkler - 135 °F (57 °C) only Model Fl FR Recessed Quick Response Extended Coverage Pendent Sprinkler Deflector: EC Installation Wrench: Model RC1 Sprinkler Wrench Approval Type: Quick Response Extended Coverage -Light Hazard Occupancy Installation Data: "K" Factor Sprinkler Nominal Thread Sprinkler Temperature" Approval' Identification Orifice Size US Metric Length ' Rating Organizations Number (SIN) 7332" 3 ' ' NPT 8.0 115 2.2' 135°F (57°C) 1, 2, 3, 4 84842 ( (2CTrrn) (R (561mm) 155°F (68°C) %" /" NPT 5.6 80 2.1" 135°F (57°C) 1, 2, a 84845 ems. T f ,� (15mm) (R1/2) (53.4mm) 155°F (68°C) VW. WW a — (') FM Approval of recessed sprinkler — 135 °F (57 °C) only. (2) Refer to escutcheon data table for approvals and dimensions. 1 _07i Qm i! z5 ens MOWN COVERAGE AREA 's Pressure, psi (bar) Maximum ' r � Flow Coverage Area R ate Wi dth X Length „AR WL gpm(Umin) K =8.0(115) K= 5.8(80) ft.xfL(mxm) 26 (98.4) 10.6 (0,7) 21.6 (1,5) 16x 16 (4.9x4.9) 33 (125.0) 17.0 (12) 34.7 (2,4) 18x18 (5.5x5.5) 40 (1514) 25.0 (1,7) 51.0 (3,5) 20x20 (60x6.0) 135 °F (57 °C) only for both Pendent and Recessed Pendent. Model Fl FR Quick Response Extended Coverage Horizontal Sidewall Sprinkler Deflector: EC - Installation Wrench: Model D Sprinkler Wrench Approval Type: Quick Response Extended Coverage -Light Hazard Occupancy Installation Data: "K" Factor Sprinkler Nominal Thread Sprinkler Approval Temperature Identification Orifice Size US Metric Length Organizations Rating Number (SIN) '' /z" '' /z" NPT 5.6 80 2 8" 1, 2, 3, 4 155 °F (57°C) R4865 ( 15mn) (R,4) (71 1mm) 175 °F (79°C) 2. 4 Model Fl FR & Fl FR Recessed Quick Response Extended Coverage Sprinklers Finishes"' Quick response sprinkler are intended for installation Standard Finishes as specified in NFPA 13. Quick response sprinklers and sprinkle' Escutcheon standard response sprinklers should not be intermixed. The Model Fl FR Recessed QREC Sprinklers are to be Bronze Brass installed as shown. The Model Fl or F2 Escutcheons Chrome Plated Chrome Plated illustrated are the only recessed escutcheons to be used White Polyester Coated White Painted with the Model F1FR Sprinklers. The use of any other Special Application Finishes recessed escutcheon will void all approvals and negate Sprinkler Escutcheon all warranties. When installing Model F1FR QREC Sprinklers, use the Bright Brass Bright Brass Model D Sprinkler Wrench. When installing Model F1FR Black Plating Black Plating Black QREC Recessed Sidewall Sprinklers, use the Model Off White Paint Off White Paint p Off White Off White GFR1 Sprinkler Wrench. Use the Model RC1 Wrench for Satin Chrome Satin Chrome installing F1FR QREC Recessed Pendent Sprinklers. Any other type of wrench may damage these sprinklers. "' Other colors and finishes are available on special order. Consult factory for details. Maintenance (2) FM Approval limited to bronze, bright and satin chrome plated, The Models F1FR QREC and F1FR QREC Recessed and polyester coated only. Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by Escutcheon Data using a soft brush or gentle vacuuming. Remove any sprinkler or damaged eel been n any painted (other ( A stock of s are model Adj Dime son w Face to � i sprinklers should be maitained to allow quick �; "(lsmm > "' /fi ' (5mm > - replacement of damaged or operated sprinklers. Prior to F1 1,2,4 x " ( installation, sprinklers should be maintained in the We (35mm) 15/ (24mm) original cartons and packaging until used to minimize the (25mm > "' ' ,s ' ( - potential for damage to sprinklers that would cause F2 1, 2, 3, 4 y 1" " (13mm) 1a " 5mm) )° 3( art,m) improper operation or non -operation. ) "' EC Pendent -.. " EC HSW Temperature Ratings °1 NYC MEA 258 -93 -E, Pendent and Recessed Pendent Only. I Sprinkler Maximum Rating Ambient Temp. Ordering Information Classification °F °C °F °C Bulb Color Specify: 1. Sprinkler Model Ordinary 135 57 100 38 Orange 2. Sprinkler Type Ordinary 155 68 100 38 Red intermediate 175 79 150 66 YelloN 3. Orifice 4. Deflector Size flector Type 5. Temperature Rating 6. 'Sprinkler Finish Sprinkler Types 7. Escutcheon Type Extended Coverage Pendent 8. Escutcheon Finish (where applicable) Extended Coverage Sidewall Note: When Model F1FR Recessed sprinklers are • EC -8 HSW Deflector ordered, the sprinklers and escutcheons are • EC -9 HSW Deflector packaged separately. Recessed Extended Coverage Pendent Recessed Extended Coverage Sidewall • EC -8 HSW Deflector • EC -9 HSW Deflector The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. The Reliable Automatic Sprinkler Co., Inc. 6� Recycled ReIiabk (800) 84-1058 Sales ces Paper (800) 848-6051 (914) Corporate Fax Fax 4) 668470 Corporate Offices Revision lines indicate updated or new data www reiiabiesprinkier.com Internet Address E G Printed in U S A 4/03 P/N 9999970142