Todd Ferking
DLR Group
421 SW 6` Avenue, Suite 1212
Portland, OR 97204
RE: SITEWORK FOR NEW OPEN PARKING GARAGE @ WASHINGTON SQUARE
Project Information
Building Permit: SIT2004 -00003 Occupancy Type: S -4
Tenant Name: Washington Square Construction Type: II -FR
Address: 9585 SW Washington Square Road Occupant Load: 976
Area: 194,720 Sq Ft Stories: 4
The plan review was performed under the State of Oregon Structural Specialty Code (OSSC)
1998 edition; and the Tualatin Valley Fire & Rescue Ordinance 99 -01 (TVFR99 -01) 1999
edition. The submitted plans are approved subject to the following.
EROSION
• Erosion control measures shall be in place prior to excavation or grading.
FIRE
• The Underground Standpipe Supply Piping shall be flushed thoroughly before
connection to the system riser in order to remove foreign materials that might have
entered the main during the course the installation. The flow rate shall not be less than
the water demand rate of the system.
• All piping shall be inspected prior to backfill.
ACCESSIBILITY
• Accessible walkways and routes shall not exceed a running slope of 1 unit vertical in
20 units horizontal (5% slope). Cross slopes shall not exceed 1 unit vertical in 50
units horizontal (2% slope).
• Accessible parking spaces and access aisles shall be located on a surface with a slope
not to exceed 1 unit vertical in 50 units horizontal in all directions. 1 104.4.3 OSSC
13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772
•
Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall
be maintained on the jobsite. The plans shall be available to the Building Division inspectors
throughout all phases of construction. 106.4.2 OSSC
American with Disabilities Act (ADA): It shall be the responsibility of the Architect,
Engineer, Designer, Contractor, Owner and Lessee to research the applicability of the ADA
requirements for the structure. The City of Tigard reviews the plans and inspects the structure
only for compliance with Chapter 11 of the OSSC which may not include all of the
requirements of the ADA.
Premises Identification: Approved numbers or addresses shall be provided for all new
buildings in such a position as to be plainly visible and legible from the street or road
fronting the property.
When submitting revised drawings or additional information, please attach a copy of the
enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of
- Tigard in tracking and proce ,-'ng the documents.
Respect
*an :,�
Senio ans Examiner
i-