Correspondence 17* 'I• . July 31, 2006 - CITY OF TIGARD OREGON JND Fire Sprinkler INC Jeff Dutton 12155 SW Grant Ave. Suite D Tigard, OR 97223 RE: FIRE SPRINKLER SYSTEM - NFPA 13D SYSTEM Project Information Building Permit: BUP2006 -00298 Occupancy Type: SR3 Address: 10495 SW Johnson Court Construction Type: VN — Sprinklered Tenant Name: Albertina Kerr Center Area: 1 Story, 2,000 Sq Ft Hazard: Light Residential The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2004 edition, and NFPA 13D. The submitted plans are approved subject to the following. GENERAL 1. The system shall be hydrostatically tested for leakage at normal operating pressure where a fire department pumper connection is not provided. 13D-4.3 2. Local water flow alarms shall be provided on all sprinkler systems in homes not equipped with smoke detectors in accordance with NFPA 72. 13D -7.6 3. Installer shall provide to the owner /occupant instructions on inspecting, testing and maintaining the system. 13D -4.2 4. Sprinkler piping should be adequately secured to restrict the movement of piping upon sprinkler operation and shall be supported with any listing limitations. 13D -7.4 5. Sprinklers frames shall not be painted or enameled unless applied by the manufacture and the sprinkler has been listed with such finishes. 13D -7.5.6 6. Minimum distance from edge of heat source to ordinary or intermediate temperature sprinklers is as follows; 13D -Table 7.5.5.3 13125 SW Hall Blvd., Tigard, OR 97223 (503) 639 -4171 TDD (503) 684 -2772 Ordinary Intermediate Front of recessed fireplace 60" 36" Side of open or recessed fireplace 36" 12" Coal or wood burning stove 42" 12" Kitchen range 18" 9" Wall oven 18" 9" Hot air flues 18" 9" Uninsulated heat ducts 18" 9" Uninsulated hot water pipes 12" 6" Side of ceiling or wall mounted 24" 12" hot air diffusers Front of wall mounted hot air diffusers 36" 18" Hot water heater or furnace 6" 3" Light fixture OW -250W 6" 3" 250W -499W 12" 6" Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.3.1 OSSC When submitting revised drawings or additional information, please attach a copy of the . - enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectfu al Henzel, Senior Plans Examiner