Loading...
Specifications Honeywell VISTA -32FB COMMERCIAL PARTITIONED FIRE AND ' BURGLARY ALARM CONTROL PANEL • Now UL864 9th Edition Approved Designed to integrate seamlessly with CCTV, access control initiating devices, notification circuits, communication devices, and Honeywell's full range of fire and burglary components, keypads, RF receivers and relays are also supported. the new VISTA -32FB provides the ultimate protection of life The VISTA -32FB has been designed to mount quickly and property. The UL Listed commercial fire and burglary and easily. control panel supports up to two partitions and up to 32 zones /points using hardwired, wireless and V -Plex° addressable technologies. A diverse line of Honeywell FEATURES • Supports addressable V -Plex access • Automatic smoke detector sensitivity • False alarm reduction features: control points using VistaKey maintenance testing - Exit error logic (One to Four doors) • Commercial Wireless Fire and - Exit delay reset • Supports eight hardwired zones, Burglary - Cross zoning - Call waiting defeat 24 V-Plex addressable points /zones, • Notification Appliance Circuits (two): - Recent close report or 32 wireless points/zones - Programmable • Can control two separate areas - Individually silenceable • Supports commercial hardwired, (partitions) independently addressable V -Plex polling loop • Carbon monoxide (CO) zone support and wireless zones • Stores up to 512 events and can (Rev 5 and higher) • Listed to UL864 9th Edition (Rev 5 accommodate 75 user codes • Programmable on board auxiliary ry and higher) • Easily programmed and maintained relay with newly upgraded Compass Downloader Software =p F TIGARD Approved plans Approved [.11... [ Conditionally Approved°.....,.°... [ ] shall be on job site. See Letter to: Follow...° .............. [ ] • Att. hued 11°11°°° .° pent* N ' ' ' " " `# OFFICE COPY A., , ..f ] rr7 a-� Bs . 1 Date : VISTA -32FB Honeywell COMMERCIAL PARTITIONED FIRE AND BURGLARY ALARM CONTROL PANEL ADDITIONAL FEATURES • Hardwired zones - Two -wire smoke detector • Up to four doors using VistaKey - Provides nine style B hardwired zone /group expansion module V -Plex Access Control zones adds two or four zones • Stored events for one call retrieval - EOLR supervised for Fire and UL - Eight zone - Class A and B burglary installations extender module • Communication - Panel operation during download - Supports N.O. or N.C. sensors - Eight zone - Class B extender - Split/Dual Reporting - Individually assignable to one of module Applications eight partitions - One zone supervised contact - Up to 16 two wire smoke detectors monitor module The VISTA -32FB control is well suited for a variety of applications as an each on zone one and two (32 total) • UL Listed wireless expansion integrated fire and burglary control. • Patented addressable V -flex polling - Supports up to 32 wireless zones/ Some of the applications supported are: loop technology points using 5881ENHC or medical and professional buildings, - Supports up to 24 two -wire V -Plex 5883H Receiver churches or synagogues, office zones /points - Supervised by control for buildings, schools, strip malls, - Global polling technology for check -in signals residences and factory or warehouse faster processing - Tamper protection for transmitters environments. - Supervised by panel - Individually assignable up to Installation - Individually assignable to partitions, eight partitions The VISTA -32FB alarm system has • notification circuit (bell) output or - Supports wireless smoke detectors been designed to mount both quickly aux relay and easily. It meets all applicable • Event reporting requirements for UL commercial fire - 4,000 ft. capability without the use . Local printer for access or and burglary installations, of shielded cable VISTA related event - Extender /Isolation bus modules Honeywell SPECIFICATIONS Electrical Main Dialer Agency Listings • Primary power: 18VAC @ 72VA • Line seize: Double Pole • FCC Part 15, Class B; FCC Part 68 ADEMCO No. 1451 • Ringer equiv.: 0.7B • UL864 /NFPA 72, Central Station and • Quiescent current draw: 300mA • Formats: ADEMCO Low Speed, Remote Station (Fire) • Backup battery: ADEMCO 4 +2 Express, ADEMCO • UL609 Local Mercantile - 12VDC, 7AH min to 34.4AH max High Speed, ADEMCO Contact ID, Premises /Mercantile Safe & Vault - Lead acid battery (gel type) Sescoa and Radionics • UL365 police station connected • Alarm power: 12VDC, 1.7A max for Cabinet dimensions burglar alarm each notification (bell) circuit output • 14.5° H X 12.5" W X 3" D • UL610 Central Station • Aux. standby pwr: 12VDC, 1A max Burglar Alarm Environmental • Total power: 2.3A at 12VDC, •Storage temp: 14° F to 158° F • California State Fire Marshal 3.4A at 24VDC from all sources ( -10° C to 70° C) • FM • 24 hours with 1A standby load • Operating temp: 32° F to 122° F • CAN /ULC S304 - Central and Fusing (0° C to 50° C) Monitoring Station Burglar Alarm Unit • Battery input, aux. and notification • Humidity: 85% RH • CAN /ULC S527 - Central Unit for (bell) circuit outputs are protected Fire Alarm Systems • EMI: Meets or exceeds the using PTC circuit protectors. All following requirements: • CAN/ULC S303 - Local Burglar outputs are power limited. - FCC Part 15, Class B Device Alarm Unit - FCC Part 68 - IEC EMC Directive • CAN /ULC S525 - Audible Signal Appliances • VISTA -32FB COMMERCIAL PARTITIONED FIRE AND BURGLARY ALARM CONTROL PANEL COMPATIBLE DEVICES Auxiliary Devices • 4190WH AlarmNet Communicators • 4204 - Relay Module, • 4193SN Two Zone Serial • 7545i -ENT - Internet/Intranet four form C contacts Interface Module Communicator • 4204CF - Two supervised • 4208U Loop Expansion Module • 7845GSM - Digital Cellular output circuits - eight zones Communicator • 5140DLM - Supervised Dialer • 4208SNF Eight Zone /2 Class A/6 • 7845i -GSM - Internet and Digital • 5881 ENHC - RF Receiver Class B Expander Module Cellular Communicator • 5883H - RF Receiver • 4293SN One Zone Serial Access Control • 6160CR -2 - Red Alpha Keypad Interface Module • VistaKey V-Plex (addressable) • 6160 - Burglary Keypad • 4297 Isolator /Extender Module Access Control • 6220S - System printer used with • V -Plex VSI Isolator Module • VistaKey SK Starter Kit 4100SM serial module V - Plex Smoke Detectors • VistaKey -EX Expansion Kit Two -Wire Smoke Detectors • 5193SD Conventional • 5193SDT Commercial Wireless Devices • 5808W3 - Photoelectronic • System Sensor V - Plex Passive Infrared Detectors Smoke /Heat Detector • ESL • 998MX • 5806W3 - Photoelectric Smoke • DSC • IS2500SN Detector Horn/Strobes • DT7500SN • 5809 - Wireless Heat Detector • System Sensor • QUEST2260SN • 5817CB - Wireless • Wheelock V - Plex Contacts Commercial Transmitter • Gentex • 4194WH • 5869 - Hold -Up Transmitter Manual Pull Stations • 4939SN -WH • 5881 ENHC - RF Receiver • 5883H - RF Receiver • 514OMPS -1 • 4944SN -WH • 5140MPS -2 • 4959SN V - flex (Addressable) Devices V - Plex Glassbreak Detectors • 4101 SN Relay Zone Module • FG1625SN • 4190SN Remote Point Module - two zones Product specifications subject to change. ORDERING VISTA -32FB 'Commercial Fire and Partitioned Burglary Alarm Platform V32FB - UL864 Rev 9 Version (Rev 5 and higher) Automation and Control Solutions Honeywell Security & Communications Honeywell 2 Corporate Center Dr. Suite 100 Melville, NY 11747 1.800.467.5875 wIsr32 October 2010 www.honeywell.com c 2010 Honeywell International Inc. • File S789 Vol. 4 Sec. 6 Page 1 Issued: 1994 -04 -15 and Report Revised: 2007 -04 -23 • DESCRIPTION PRODUCT COVERED: USL, CNL - Combination Control /Communicator Models 5140XM, Vista 100, Vista- 128FB, Vista- 128FBP, Vista- 250FBP, VISTA- 250FBPADT, FA1600C, FA1700C and Vista -32FB intended for use with Model 1451 Transformer. ENGINEERING CONSIDERATIONS (NOT FOR UL REPRESENTATIVE USE): ##: For Canadian Versions Only USL indicates evaluation to the following Standards: *UL 609 -Local Burglar Alarm Units and Systems *UL 365 - Police Station Connected Burglar Alarm Units and Systems *UL 1610 - Central Station Burglar Alarm Units *UL 1635 - Digital Alarm Communicator System Units *UL 864 - Control Units For Fire - Protective Signaling Systems. CNL indicates evaluation to the Standard for Central and Monitoring Station Burglar Alarm Units, CAN/ULC- S304 -M88, the Standard for Fire Protective Signaling Systems, CAN/ULC- S527 -M89, and the Standard for Supervising Station Communication Systems, NFPA -72, Section 4 -5. Suitable for Local Protective Signaling System use when used with suitable sounding device. Compatible alarm indicating /notification appliances, with EOL supervision, shall be employed as indicated in the control unit's installation instructions. Battery and loading requirements shall be configured as described in the Installation Instructions to provide for 24 hours of normal standby power and at least 5 minutes of general alarm standby power. Combined auxiliary power and alarm currents shall not exceed 2.3 A. Suitable for Central Station Protective Signaling Service when used with Model 7620ULF, 7720ULF or with Model5140DLM for central station monitoring. Local alarm indicating /notification appliance use is optional subject to the requirements of the Local Authorities Having Jurisdiction. Battery and loading requirements shall be configured as described in the Installation Instructions for Central Station service. Suitable for Remote Station Fire Alarm System Service when used with Model 5140DLM. Local alarm indicating /notification appliance use is optional subject to the requirements of the Local Authorities Having Jurisdiction. Battery and loading requirements shall be configured as described in the Installation Instructions for Remote Station service to provide 60 hours of normal standby power and at least 5 minutes of general alarm standby power. ## A total of eight operator keypads, (Model 6139CN or FA560KP) may be connected to each control unit by means of the four -wire bush provided. ## The Model 6137B, 6139B, 6150 and 6160 keypads are intended for use with the Vista -128FB control unit and are connected by means of the 4 -wire bus. # #: When connected to SRRF signal receiver, Model 5882, wireless devices may be used. File S789 Vol. 4 Sec. 6 Page 2 Issued: 4 -15 -94 and Report Revised: 6 -5 -00 Suitable for Grade A local mercantile Burglar Alarm Service when used with a Listed Burglar Alarm Sounding Device/Housing. Depending upon installation application a compatible Listed sounding device enclosure may also be required. As indicated in the Installation Instructions a Listed tamper switch shall be used to protect the control unit's cover and all conduit openings to the control shall be used or blocked. As a result of the attack test results described in File S789, Report dated August 12, 1992 the maximum entry delay time shall not exceed 45 s and maximum exit delay time shall not exceed 60 s. Suitable for safe and vault burglar alarm installations when also used with a shock sensor Listed for protection of sheet metal enclosures and a Listed tamper switch installed on the rear of the control unit. Suitable for Grade A Police Station Connected Burglar Alarm System Service when the 24 hour test report is enabled, programmed for 24 hour Test Reporting, or can be used with Model 346 polarity reversing relay /voltage booster or Model 7720, or 7620ULF Long Range Radio, or 5140DLM Backup Dialer (Basic Line Security). Suitable for Grade AA (High Line Security) when used in conjunction with Model 445 direct wire transmitter or Model 7920SE Long Range Radio. The digital alarm communicator transmitter shall be programmed for UL installations as stated in the Installation Instructions. Suitable for Grade C Central Station Service, Grade B Central Station Service when used with a Listed Mercantile Sounding Device. Depending upon the installation application a compatible Listed sounding device enclosure may also be required. Suitable for Grade A Central Station Service when used with Model 7720 Long Range Radio or Model 7620ULF Long Range Radio. One zone of the control panel shall be programmed as a 24- hour zone to supervise the radio unit. Suitable for Grade AA, BB or CC Central Station service when used with the 7920SE Long Range Radio as indicated in the installation instructions. As indicated in the Installation Instructions a Listed tamper switch shall be used to protect the control unit's cover and all conduit openings to the control shall be used or blocked. Suitable for safe and vault burglar alarm installations when also used with a shock sensor Listed for protection of sheet metal enclosures and a Listed tamper switch installed on the rear of the control unit. The Vista 100 and 128FB Controls can be partitioned into a maximum of 8 areas. The Vista -32FB can only be partitioned into a maximum of 2 areas. All fire zones shall be assigned to partition 1. The manufacturers installation instructions shall be observed for all UL applications of zone partitioning. Except for the following differences the Vista -32FB is identical to the Vista- 128FB. The Vista -32FB: A) Has reduced software features. B) The primary transformer is mounted inside the control unit enclosure and is separated from the rest of the control unit wiring by a sheet steel frame. File S789 Vol. 4 Sec. 6 Page 2A Issued: 1994 -04 -15 and Report Revised: 2007 -04 -23 The Vista- 128FBP is identical to the Vista -128FB except for the addition *of the following features: Internet Communication Module, cancel verify, Fire verity, Quick exit, Group bypass, Arm faulted, Stayl, Stay2, Auto stay silent burg, and tamper option each zone. The Vista- 250FBP is identical to the Vista- 128FBP except that it supports 16 vista key modules, 250 zones, 250 users, 1000 event log, and 500 vista card holders. The FA1700C is the First alert version of the Vista- 250FBP). The Vista- 250FBPADT is identical to the Vista- 250FBP except for ADT defaults and the changes in hardware and software to support the AC communicator module, Model 472491 D. The AC Communicator module, Model 472491D, can only be used as a dedicated AC telephone line mode. The Vista- 250FBPADT is suitable for used with the Internet Communication Module, Models 7845i, 7845i -ENT and the Premises Cellular Control Channel Transceiver, Model 7845C. The Models 7845i, 7845i -ENT and 7845C device must either be mounted in the control panel cabinet, or within 3 feet of the panel cabinet with wiring routed in conduit. All commercial fire alarm installations shall comply with the installation requirements contained in NFPA 72 - National Fire Alarm Code. All UL commercial burglar alarm installations shall comply with the installation requirements contained in UL Standard 681, Installation And Classification of Burglar And Holdup Alarm Systems. Each control unit is intended to be used with other separately Listed devices as indicated in the manufacturer's Installation Instructions. Two wire and four wire smoke detectors shall be installed as specified by the control unit's installation instructions. The units are intended for the applications described in Table I. ## In order to provide fire protective signaling service, the Model Vista -128FB control units shall be provided with a backup signaling channel by means of the Model 7835CF cellular control channel transceiver, which is connected to the control unit by means of the data communication bus designed for this purpose. ## The Model Vista -128FB unit is powered from a Class II limited energy plug -in type transformer and two sealed lead acid batteries provide 24 -hour standby capacity. ## The system shall be installed in accordance with the Manufacturer's Installation Instructions and the Canadian Electrical Code, Part I. Model FA 1600C is identical to Vista -100 except for model designation. CITY OF NEW YORK DEPARTMENT OF BUILDINGS Pursuant to Administrative Code Section 27 -131, the following equipment or material has been found acceptable for use in accordance with the Report of Materials and Equipment Acceptance (MEA) Division. Richard C. Visconti, R.A., Acting Commissioner MEA 82 -93 -E Vol. XV Report of Material and Equipment Acceptance Division Manufacturer - Alarm Device Manufacturing Company, A Division of The Pittway Corporation, 165 Eileen Way, Syosset, New York 11791. Trade Name(s) - ADEMCO. Product - Commercial fire alarm systems. Pertinent Code Section(s) - Reference Standard RS -17. Test(s) - UL 864/NFPA 72 for Fire - Protective Signaling Systems UL 609 (Tenth Edition) - Local Burglar Alarm Units and Systems UL 365 (Third Edition) - Police Stations Connected Burglar Alarm Units and Systems. UL 1610 (Second Edition) - Central Station Burglar Alarm Units UL 1635 (Second Edition) - Digital Alarm Communicator System Units UL 864 (Seventh Edition) - Control Units For Fire- Protective Signaling Systems. Laboratory - Underwriters Laboratories, Inc. • Test Report(s) - File S789 Project 93ME37527 dated April 15,1 994 and Revised July 28, 1999, and UL letter dated January 5, 2000. Description - The Vista -32FB is a combination Control /Communicator. It is suitable for Local Protective Signaling System, Central Station Monitoring and Remote Station Fire Alarm System Service. The following models are added under this amendment: Model No. ! Description 472491 AC Communicator Module 472462 Combined Control /Communicator Panel (Focus 200 Plus) Vista -32FB i Combined Control /Communicator Panel 472490 RF Gateway with radio frequency for use with Focus 200 Plus Control Panel 7835CF Cellular Transceiver 4101 SN -XX ! Multiplex Single Zone Expander & Relay Module MEA 82 -93 -E Vol. XV 1 of 2 pages Pursuant to "Promulgation of the Rules relating to Material and Equipment Application Procedures" dated November 5, 1992, the Bureau of Fire Prevention has no objections letter dated March 13, 2000, F.P. Index #0001012. Recommendation — That the above units be accepted on condition that all uses, configurations, arrangements and functions, locations and installations comply with the New York City Building Code, specifically Subchapter 17, and Reference Standard RS 17 -3 through RS 17 -3C, NFPA 72, UL listing, manufacturer's instructions, the New York City Electrical Code, and appropriate conditions of previous amendments and on further condition that: 1. The connection of security/burglar devices and equipment to that submitted for acceptance for fire alarm usage under this MEA application is prohibited within New York City and such equipment and devices shall be so permanently labeled. All shipments and deliveries of such equipment shall be provided with a metal tag, suitably placed, certifying that the equipment shipped or delivered is equivalent to those tested and accepted for use, as provided for in Section 27- 131 of the Building Code. Final Acceptance .&2r2-io1 Examined By MEA 82 -93 -E Vol. XV 2 of 2 pages RECEIVED I.Y. 0 AK) 02 201? Lj WIRING LEGEND CITYOFTIGARD REF WIRING COLORS DEVICE BUILDJT DIVISION A 18/2 FPLR RED INITATION GENERAL NOTES: B 14/2 FPLR RED NOTIFICATION 1. DETECTOR LOCATIONS ARE APPROXIMATE ONLY. 2. ALL DETECTORS SHALL BE SPACED NO MORE THAN 30 FT. APART. 3. ALL DETECTORS SHALL BE LOCATED AT LEAST 36 IN. FROM ANY FIRE ALARM LEGEND SUPPLY OR RETURN AIR SOURCE. 4. DETECTORS SHALL BE MOUNTED NO CLOSER THAN 12 IN. FROM SYMBOL DESCRIPTION BACKBOX REQUIRED ANY WALL. 5. DETECTOR SPACING IS FOR SMOOTH CEILINGS. IFACPI FIRE ALARM CONTROL PANEL SELF CONTAINED 6. MANUAL PULL STATIONS SHALL BE LOCATED 48 IN A.F.F. TO TOP. OS SMOKE DETECTOR 4" SQUARE WITH 3/0 MUD RING 7. AUDIBLE ALARM DEVICES SHALL BE LOCATED 82 IN, A.F.F. TO CENTER. 8. ALL BACK. BOXES SHALL BE PAINTED RED. III PULL STATION 4" SQUARE WITH SINGLE GANG MUD RING 9. PROVIDE EARTH GROUND FOR ALARM PANELS SEPARATE O TAMPER SWITCH BY OTHERS FROM A/C HOOK UP 10. NOTE ANY CHANGES OR VARIATIONS ON WORKING DRAWINGS. OW FLOW SWITCH BY OTHERS z 0 FACP ZONE 4 A O EOL i ZONE 3 A EOL 2 PHONE LINES OR CATS D oz . 120VAC ZONE 2 A © EOL �LL ' r :/ - .C:) '1 � 6 EARTH GROUND ZONE 1 A EOL SEPERATE TO 'II COLD WATER PIPE I'' N rn RISER DIAGRAM 3 17 N N Ni U m O) O O °t3 0 O °o 111 0 C ontrol Unit SYSTEM OPERATION MATRIX 6. Z Z Annunciator Notification lb____ S Mix 0 a N C M '5 Q O O Q 0. C (1 a o a LV- )0 cc cc -.E' - a) o C o o c FIELD VERIFY LOCATION Z C 0 " c . N EOL (ZONE 2) a c U o a) A Q Q C • I © I Q E - o c o I 2A A V W [F] 903.4.2 Alarms. Approved audible devices shall be con - I o N r a Q N c `- cn 0 A A EOL (ZONE 1) nected to every automatic sprinkler system. Such sprinkler Q °' Q., Q , c , `^ 4, > waterflow alarm devices shall be activated by waterflow z 0 c EOL (ZONE 4) equivalent to the flow of a single sprinkler of the smallest m w N '5av `v a 0 9 g P .< a ' a a � ' ~ m EOL (ZONE 3) orifice size installed in the system. Alarm devices shall be <n N o Q.) y °' E °: ■ - — — - - — - - — - - provided on the exterior of the building in an approved loca- z ° ° 06 > > > c c a = w oz, tion Where a fire alarm system is installed, actuation of the > 0 Q FIRE ALARM SYSTEM < a a - t o a automatic sprinkler system shall actuate the building fire w 1= a SYSTEM INPUTS _ alarm system. 0 J LL 1 Manual Pull Stations x x _ x 2 Smoke Detectors x x x a 3 Waterflow Switches x x x a 4 Tamper Switches X X o W V T _i 5 AC Power Failure x X Y /7:' 6 DC Low Battery x x ill Z 7 Ground Fault x X i[ l a i 8 Open Circuit x x PARTIAL FLOOR PLAN — FIRE ALARM gc3 � � �� 9 Notification Appliance Circuit Short x X SCALE NTS FA -1 1 , r DMP XR 1001XR500 Battery Calculation 7419/2012 . Job Name: Events Unlimited, 96830 SW Bonita Rd., Tigard Oregon ® Installing Company: Allied Fire & Security XR500 /XR100 SERIES STANDBY BATTERY POWER CALCULATIONS Standby Current Alarm Current XR500 /XR100 Series Control Panel Qty 1 X 180 mA 180 mA Qty 1 X 180 mA 180 mA Relay Outputs 1 -2 (ON) QtY X 30 mA 0 mA Qty 0 X 30 mA 0 mA Switching Grounds 3 -6 (ON) Qty X 5 mA 0 mA Qty 0 X 5 mA 0 mA Active Zones 1 -8 Qty X 1.6 mA 0 mA Qty 0 X 2 mA 0 mA' Active Zones 9 -10 Qty X 4 mA 0 mA Qty 0 X 30 mA 0 mA' 2 -Wire Smokes Qty X 0.1 mA 0 mA Qty 0 X 0.1 mA 0 mA' Panel Bell Output Amount of Bell Current drawn 1500mA Maximum 1500 mA 120 mA I 461 Interface Adaptor Card Qt X 7 mA 0 mA • 0 X 7 mA 0 mA 462P Printer Interface Card Qty X 50 mA 0 mA Qt 0 X 50 mA 0 mA 481 Expansion Interface Card Qty X 15 mA 0 mA Qty 0 X 15 mA 0 mA 866 5 le W Notification Module Qty X 45 mA 0 mA Qt 0 X 76 mA 0 mA 869 Class A Style D Module Qty X 25 mA 0 mA Qty 0 X 75 mA 0 mA CellComRT GSM /GPRS Di•ital Cellular Communicator Qty X 21 mA 0 mA • 0 X 200 mA 0 mA 630F Remote Fire Command Center Qty X 63 mA 0 mA • 0 X 92 mA 0 mA 7063/7163 Thinline /7063A Aqualite Keypad Qty X 85 mA 0 mA • 0 X 100 mA 0 mA 7073/7173 Thinline /7073A Aqualite Keypad Qty X 85 mA 0 mA Qty 0 X 100 mA 0 mA Active Zones (EOL installed) Qt X 1.6 mA 0 mA Qt 0 X 2 mA 0 mA' ePAD Virtual Keypad Qty X 80 mA 0 mA Qt 0 X 80 mA 0 mA 734 Wiegand" Interface Module Qty X 15 mA 0 mA Qty 0 X 15 mA 0 mA Active Zones (EOL installed) Qty X 1.6 mA 0 mA Qty 0 X 2 mA 0 mA' 734N Wiegand" Interface Module Qty X 100 mA 0 mA Qty 0 X 110 mA 0 mA Active Zones (EOL installed) • X 1.6 mA 0 mA Qt 0 X 2 mA 0 mA' 738A Ademco Wireless Interface Qty _ X 75 mA 0 mA Qty 0 X 75 mA 0 mA w /Receiver •t X mA 0 mA Qty 0 X mA 0 ma 739 X10 Interface Module Q X 13 mA 0 mA Qty 0 X 13 mA 0 mA 710 Bus Splitter /Repeater Qty X 30 mA 0 mA Qty 0 X 30 mA 0 mA 711 Zone Expander Qty _ X 11 mA 0 mA Qty 0 X 11 mA 0 mA Active Zones (EOL installed) Qty X 1.6 mA 0 mA Qty 0 X 2 mA 0 mA' r. . _. - . 714 Zone Expander Qty X 7 mA 0 mA Qty 0 X 7 mA 0 mA Active Zones (EOL installed) Qty X 1.6 mA 0 mA Qty 0 X 2 mA 0 mA' 712• ' . ,,r,77— :MT- . Active r:r, _ 7148 or 714 -16 Zone Expander Qty _ X 20 mA 0 mA Qty 0 X 20 mA 0 mA Active Zones (EOL installed) Qty X 1.6 mA 0 mA Qty 0 X 2 mA 0 mA' 71'5tot1Ee lfMt1 ., -...- ''- '' - -? ._- 7 s? <° 1!q(% Y , 7 '► .:::w! b Art1A •:AFY�m Q.M x,4_, mA D . , mA 715 -8 or 715 -16 Zone Expander Qty X 20 mA 0 mA Qty 0 X 20 mA 0 mA Active Zones (EOL installed) Qty X 4 mA 0 mA Qty 0 X 30 mA 0 mA' 2-Wire Smokes Qt X 0.1 mA 0 mA Qty 0 X 0.1 mA 0 mA' 717 Graphic Annunciator Qty X 10 mA 0 mA Qty 0 X 10 mA 0 mA Annunciator Outputs Qty 0 X 1 mA 0 mA 521 LX, 521 LXT Smoke Detectors Qty X 8.8 mA 0 mA Qt 0 X 28 mA 0 mA' SLR- 835B /BH Photoelectric Smoke Detector Qty X 0.38 mA 0 mA • 0 X 150 mA 0 mA' SLR -835H Heat /Smoke Detector Qty X 0.38 mA 0 mA Qty 0 X 150 mA 0 mA' MP -5365 MiniProx" Reader Qty X 20 mA 0 mA Qty 0 X 110 mA 0 mA' MX -5375 MaxiProx® Reader Qt X 200 mA 0 mA Qty 0 X 700 mA 0 mA' 572 Indicator LED Qty X 20 mA 0 mA Qty 0 X 20 mA 0 mA' 5820A ShatterPro' Glassbreak Qty X 12 mA 0 mA s 0 X 25 mA 0 mA' FG - 730 Flexguard Glassbreak Qty X 25 mA 0 mA •. 0 X 25 mA 0 mA' PI 6000 Sharpshooter' w/ Pet Immunity Qty X 14 mA 0 mA Qty 0 X 20 mA 0 mA' 6155LX Sharpshooter' PIR Qty X 23 mA 0 mA Qty 0 X 25 mA 0 mA' AP669 Sentrotm 360' PIR Qty X 11 mA 0 mA Qty 0 X 13 mA 0 mA' RX -40PI Optex" 40' x 40' PIR w/ Pet Immunity Qty X 17 mA 0 mA Qty 0 X 17 mA 0 mA" CX -702 Optex" 70' x 70' PIR Qt X 20 mA 0 mA Qty 0 X 20 mA 0 mA' SX -360Z 0.tex' Extra Long Range 360° PIR Qty X 13 mA 0 mA Qty 0 X 18 mA 0 mA' MX•40PI Optex PIR /Microwave Detector Qty X 18 mA 0 mA Qty 0 X 20 mA 0 mA' PA -450PI Takex Wide An • le Wall Mount PIR 367(84' Qty X 25 mA 0 mA Qt 0 X 25 mA 0 mA' `°iii PA -470L Takex Lon: Ran:e Wall Mount PIR 53X84' Qty X 28 mA 0 mA • 0 X 28 mA 0 mA' .:e PA -6805 Takex S..t Ceilin• Mount PIR 360X13' Qty X 35 mA 0 mA • 0 X 35 mA 0 mA' n - PA -6812 Takex Wide An • le Ceilin • Mount Mirror 0. is PIR 40)(84' Qt X 35 mA 0 mA • 0 X 35 mA 0 mA• EVD -1 Electronic Vibration Detector Qty X 26 mA 0 mA Qty 0 X 34 mA 0 mA• I VSA -S Vault Sound Alarm Qty . _ X 20 mA 0 mA Q 0 X 25 mA 0 mA: X. IFTerrrtirie � E1 - �� eie ®��zaR_e ®q�reia�e�s�ar•e� <fat er { Rd I.X -Bus modutesi e, w-.. _+::4 . „,, ,. ,., •i Aux. Powered Devices Qty X mA 0 mA Qty 0. X nA 0 mA• Aux. Powered Devices Qty X mA 0 mA Qty 0 X mA 0 mA' 111111111111.111111111MMILL___ .. .1... Aux. Powered Devices Qty X mA 0 mA Qty 0 X mA 0 mA' Aux. Powered Devices Qt X mA 0 mA Qty 0 X mA 0 mA* Aux. Powered Devices •t X mA 0 mA Qty 0 X mA 0 mA' 1 ' Based on 10% active zones in alarm Total Standby 180.7 mA Total Alarm 360 mA Required Minimum Alarm Time in minutes 4 I > 5 Minutes 0.083 Number of standby hours needed < I > 24 Total number of standby mA hours 4337 Total required alarm current 30 Total number of mA hours 4367 Contingency factor 0% = 4367 7 - Battery Amp hours required 5 See Standby Battery Selection Section of XR500 /XR100 Series Installation Guide (LT -0681 or LT- 0899). This spreadsheet calculator has not been evaluated by UL. �� -. DMP is not responsible for errors, omissions or inaccuracies. W / 3 / y/ 7JV