Specifications qy5 / UJa . S - / ,ce p- d /
Form 4a Project Name: VAN'S - TIGARD, OR Page: 1
' SYSTEMS - GENERAL
Applicability Plans /Specs
(, ; .Discussion of qualifying Show compliance by including a d' • t$', �t l er,
exceptions on Dade 4 -25 specification section and subpara. r -i. .
1. Applicablity (Section 1317)
• Is this form required? DEC 0 9,2009
0 Form Required. Complete form if a new HVAC system is being installed, or comp . -
existing HVAC system are being replaced (I.e., equipment, controls, ductwork, ang o! . • A78
I ISION
❑ Exception. The building or part of the building qualifies for an exception from HVAC code
requirements. Applicable code exception is Section 1317.1. Portions of the building that
qualify:
Area: Exception ❑ -1 ❑ -2 ❑ -3
Area: Exception ❑ -1 ❑ -2 ❑ -3
Area: Exception ❑ -1 ❑ -2 ❑ -3
❑ Form Not Required. This project does not contain work required to comply with code.
2. Simple or Complex Systems (Section 1317.9 or 1317.10)
o Simple System. Building contains only Simple HVAC System(s). Complete this form (4a) and
equipment efficiency worksheets as required. Form 4b is not required.
El Complex System. Project includes a Complex System. Complete this form (4a), form 4b and
equipment efficiency worksheets as required.
3. Equipment Performance (Section 1317.5)
❑ No New HVAC Equipment. The building plans do not call for new electrical HVAC equipment,
combustion heating equipment, or heat - operated cooling equipment.
El Complies. All new HVAC equipment have efficiencies not less than those required by code.
The following equipment efficiency worksheets are attached:
❑ -4a ❑ -4b ❑ -4c ❑ -4d ❑ -4e ❑ -4f ❑ -4g ❑ -4h ❑ -4i ❑ -4
4. Duct Insulation and Sealing (Sections 1317.7 & 1317.8)
❑ No Ducts. The building plans and specifications do not call for new HVAC ducts or plenums.
is Complies. The plans and specifications call for all air - handling ducts and plenums to be
insulated and sealed as required by Sections 1317.7 81317.8.
1
5. Distribution Transformers (Section 1316.1)
El No Distribution Transformers. The plans /specs do not call for new distribution transformers.
❑ Complies. All new distribution transformers comply with efficiency, testing, and labeling P ED PRop
requirements of Section 1316.1.1. e � ��cS',
El Exception. The project qualifies for an exception per Section 1316.1.1, Exceptiion: �O 9 02
❑ -1 ❑ -2 ❑ -3 ❑-4 ❑ -5 ❑ -6 ❑ -7 ❑ -8 ❑ -9 ❑ -10 ❑ -1 0 -12 CI -1.1 El -la cc 83363PE -
Attach relevant documentation for appropriate exception. The plans /specs show complia ' (OREGON c/
following locations: A d o co
` `e o-• � A.
"i N PQ
4 -1 EXPIRES: JU NE 30.2G iL
I Compliance with OSSC, effective 04/01/07
Form 4a Project Name: VAN'S - TIGARD, OR Page: 2
SYSTEMS - GENERAL
6. HVAC Controls (Section 1317.4)
6.1 System Thermostat /Zone Controls (Section 1317.4.1)
El Complies. All new HVAC systems include at least one temperature control device responding to
temperatures within the zones.
E l Exception. HVAC system qualifies for an exception from zone control requirements.
The applicable code exception is Section 1317.4.2, Exception ❑ -, 0-2
Portions of the building that qualify:
The plans /specs show compliance in the following locations:
6.2 Off - hour Controls - Auto Setback or Shutdown (Section 1317.4.3)
El Complies. Systems must have at least one of the following features:
E l Control Setback Complies. Each system is equipped with automatic control capable of reducing •
energy through control setback during periods of non -use or alternate use of spaces served.
ID Equipment Shutdown Complies. Each system is equipped with controls capable of reducing
energy use through automatic shutdown during periods of non -use or alternate use of spaces.
HVAC systems with equipment shutdown are equipped with at least one of the following:
0 Programmable controls (1317.4.3.1 (1))
❑ Occupant sensor (1317.4.3.1 (2))
❑ Interlocked to a security system (1317.4.3.1 (3))
❑ Manually activated timers with 2 -hour operation max (1317.4.3.1 (4))
❑ Exception. The building qualifies for an exception to the requirement for automatic setback or
shutdown controls. The applicable code exception is Section 1317.4.3
Exception 0-1 0-2
The plans /specs show compliance in the following locations:
6.3 Control Capabilities (Sec. 1317.4.2.1)
El Complies. Zone thermostats are capable of being set to the temperatures described in Sec.
1317.4.2.1. Where used to control both heating and cooling, zone controls shall be capable of
providing a temperature range or deadband of at least 5 degrees F within which the supply of
heating and cooling energy to the zone is shut off or reduced to a minimum.
E l Exception. The building qualifies for an exception to the deadband requirements.
The applicable code exception is Section 1317.4.2.1 Exception 0-1 0-2
Portions of the building that qualify:
The plans /specs show compliance in the following locations:
6.4 Optimum Start Controls (Section 1317.4.3.2)
I Complies. Separate HVAC systems have controls capable of varying start-up time of system to
just meet temperature set point at time of occupancy.
❑ Exception. HVAC systems have a design supply air capacity not exceeding 10,000 cfm.
The plans /specs show compliance in the following locations:
6.5 Heat Pump Controls (Section 1317.4.4)
ID No Heat Pump. The plans /specs do not call for a new heat pump
❑ Complies. All new heat pumps equipped with supplementary heaters are controlled to minimize
the use of supplemental heat as defined in Section 1317.4.4.
- "), The plans /specs show compliance in the following locations:
4 -2
Compliance with OSSC, effective 04/01/07
Form 4a Project Name: VAN'S - TIGARD, OR Page: 3
SYSTEMS - GENERAL
7. Economizer Cooling (Section 1317.3)
❑ No Cooling. The building plans do not call for a new fan system with mechanical cooling.
❑ Complies. Each new fan system has an air economizer capable of modulating outside -air and
return -air dampers to provide up to 100 percent of the design supply air as outside air.
❑ Exception At least one new fan system qualifies for an exception. The applicable code exception
is Section 1317.3, Exception ❑ -1 ❑ -2 ❑ -3 ❑ -4 ❑ -5 ❑ -6 ❑ -7
If Exception 3 is selected complete the following:
(a) Total cooling capacity of exempt units (Btu /hr)
(b) Total installed building cooling capacity (Btu /hr)
❑ Complies. Sum of exempt units rated at less than 54,000 Btu /hr is <240,000 Btu /hr or a/b
< 0.10 (10% of total building cooling capacity).
Unit Identifier of exempt units:
The plans /specs show compliance in the following locations:
M -1.1
8. Economizer Pressure Relief & Integration (Section 1317.3.1 and 1317.3.2)
o No Economizers Required. Project does not contain a new fan system requiring economizers.
❑ Overpressurization Complies. The drawings specifically identify a pressure relief mechanism for
each fan system that will relieve the extra air introduced by the economizer.
❑ Integration Complies. Economizer is capable of providing partial cooling even when additional
mechanical cooling is required to meet the remainder of the cooling load.
❑ Exception. The applicable exception is Section 1317.3.2, Exception ❑ -1 ❑ -2
The plans /specs show compliance in the following locations:
9. Hot Gas Bypass (Section 1317.5)
GI No Hot Gas Bypass
❑ Complies. See allowable amount of hot gas bypass as a percentage of total cooling capacity in
table below.
Unit ID Rated Cooling Capacity Hot Gas Bypass Capacity
Allowable Hot Gas Bypass
Rated Cooling Capacity Max Hot Gas Bypass
^ .lf
<240,000 Btu /hr 50%
`/ >240,000 Btu /hr 25%
❑ Exception. Unitary packaged system with cooling capacity no greater than 90,000 Btu /h
4 -3
Compliance with OSSC, effective 04/01/07
Form 4a Project Name: VAN'S - TIGARD, OR Page: 4
•. SYSTEMS - GENERAL
10. Shutoff Dampers (1317.4.3.3)
Not Required. Shutoff dampers are not required on this project.
❑ Complies. Each outdoor air supply & exhaust system shall be equipped with motorized dampers.
El Exception. The building qualifies for an exception to the motorized damper requirement. The
applicable code exception is Section 1317.4.3.3 Exception ❑ -1 ❑ -2 ❑ -3 ❑ -4 ❑ -5 ❑ -6
The plans /specs show compliance in the following locations:
10.1. Shutoff Damper Controls (Section 1317.4.3.3.1)
o Complies. Outdoor air supply and exhaust systems shall be provided dampers that automatically
shut when systems or spaces served are not in use or during building warm -up, cooldown, or
setback.
❑ Complies. Stair and shaft vents are capable of being automatically closed during normal building
operation and interlocked to open as required by fire and smoke detection systems.
The plans /specs show compliance in the following locations:
10.2. Motorized Damper Leakage (1317.4.3.3.2)
o Complies. Motorized outdoor air supply and exhaust air dampers have a maximum leakage rate
of 4 cfm /ft2 at 1.0 in w.g. when tested in accordance with AMCA Standard 500 -1998.
❑ Exception. Packaged HVAC equipment may have maximum leakage rate of 20 cfm /ft at 1.0 in
w.g. when tested in accordance with AMCA Standard 500 -1998.
The plans /specs show compliance in the following locations:
11. Piping Insulation (Section 1314)
No New Piping. The building plans and specifications do not call for new piping serving a
heating or cooling system or part of a circulating service water heating system.
❑ Complies. All new piping serving a heating or cooling system or part of a circulating service
water heating system complies with the requirements of the Code, Section 1314.1.
❑ Exception. New piping qualifies for exception: Section 1314.1, Exception ❑ -1 ❑ -2
12. Occupancy Ventilation
Complies. Mechanical ventilation systems provide the required amount of ventilation is indicated
in plans /specifications as specified in Chapter 4 of the Oregon Mechanical Specialty Code.
❑ Complies. Natural ventilation systems provide required amount of ventilation as certified by a reg-
istered architect or engineer as specified by Section1203.4.1, Exception. Attach worksheet 4m.
The plans /specs show compliance in
the following locations:
The plans /specs show compliance
on the following pages:
INV:%1
4-4
Compliance with OSSC, effective 04/01/07
Form 4a Project Name: VAN'S - TIGARD, OR Page: 5
SYSTEMS - GENERAL
13. High Occupancy Ventilation (Section 1317.2.2)
El Complies. HVAC systems with ventilation air capacities of 1,500 CFM or greater that serve areas
having an average occupant load of 20 square feet per person or less from Table 1004.1.2 have a
means to automatically reduce outside air intake.
Identify applicable systems:
Plans /specs indicate where equipment (i.e. carbon dioxide sensor) and sequence is specified:
❑ Exception. HVAC systems are equipped with an energy recovery device with at least 50%
recovery effectiveness.
❑ No High Occupancy Systems. Project does not contain an HVAC system as described above.
14. Exhaust Air Heat Recovery (Section 1318.3)
El Not Regulated. HVAC system does not have: 1) design supply air cap. of >10,000 cfm, and 2)
min. outside air supply >70 %, and 3) at least 1 exhaust fan rated at 75% of min outside air supply.
❑ Complies. Heat recovery system increases outside air temperature by 20 °F (Climte Zone 1) or
30 °F (Zone 2) and has provision to provide bypass during air economizer mode.
❑ Exception. An HVAC system qualifies for an exception to this requirement. Applicable exception
from Section 1318.3 Exception ❑ - ❑ - ❑ -s 0-4 0-5 0-6 0-7
The plans /specs show compliance in the following
locations:
15. Large Volume Fan Systems (Section 1318.4.2.4)
El Not Regulated. The building plans or specifications do not call for fan systems over 15,000 CFM
that serve a single zone and function for the purpose of temperature control.
❑ Complies. Fan systems are equipped with variable frequency drive or two speed motor to reduce
airflow as required by Section 1318.4.2.3.
The plans /specs show compliance in the following
locations:
16. Variable Speed Drives (Section 1317.10.3.1)
El Not Regulated. The building plans or specifications do not call for fan and pump motors 10
horsepower and greater that serve variable -flow air or liquid systems.
❑ Complies. All fan and pump motors 10 hp and greater which serve variable -flow air or liquid
systems are controlled by a variable -speed drive.
❑ Exception. The building qualifies for an exception to the variable -speed drive requirement.
Portions of the building that qualify:
Applicable code exception is Section 1317.10.3.1, Exception
The plans /specs show compliance in the following
locations:
17. Service Water Heating (Sec. 1315)
El No New Water Heating. The building plans and specifications do not call for new water heaters,
hot water storage tanks or service hot water distribution systems.
❑ Complies. All new water heaters, hot water storage tanks or service hot water distribution
systems comply with the requirements of the Section 1315.
❑ Exception. The applicable code exception is Section: Exception: Portions of the building that qualify:
'-`812 The plans /specs show compliance in the following locations:
4 -5
Compliance with OSSC, effective 04/01/07
r •+
Form 4a Project Name: VAN'S - TIGARD, OR Page: 6
SYSTEMS - GENERAL
18. Swimming Pools, Spas and Hot Tubs (Section 1315.5)
o No New Pools. The building plans and specifications do not call for new, swimming pools, spas
or hot tubs.
❑ On /Off Controls Complies. Spa and hot tub heaters are equipped with a readily accessible
ON /OFF switch as required by Section 1315.5.1.
❑ Ventilation Controls Complies. Pool ventilation system is controlled based on humidity.
❑ Cover Complies. All heated pools, hot tubs and spas are equipped with a cover.
❑ Heat Recovery Complies. Pools, Spas, and hot tubs, over 200 ft utilize recovered heat as
required by Section 1315.5.3.
❑ Exception. Heat recovery is not necessary as pool is heated by renewable energy or
waste heat recovery sources capable of providing at least 70 percent of the heating
energy required over an operating season.
19. Fume Hoods (Section 1317.2.1.)
o No Fume Hoods. The building plans do not call for fume hood systems that have a total exhaust
rate greater than 15,000 cfm.
❑ Complies. Fume hood systems have at least one of the following features:
❑ Variable air volume hood exhaust and room supply systems capable of reducing exhaust
and makeup air volume to 50% or less of design values.
❑ Direct makeup (auxiliary) air supply equal to at least 75% of the exhaust rate, heated no
warmer than 2° F below room set point, cooled no cooler than 3° F above room set point,
no humidification added, and no simultaneous heating and cooling used for
dehumidification control.
❑ Heat recovery systems to precondition makeup air from fume hood exhaust in accordance
with 1318.3 - Exhaust Air Energy Recovery, without using any exception.
The plans /specs show compliance in the following locations:
•
20. Parking Garage Ventilation (Section 1317.2.3)
o No Enclosed Garages. The building plans and specifications do not call for enclosed Group S -2
parking garages with a ventilation exhaust rate greater than 30,000 CFM.
❑ Complies. The plans and specifications call for carbon monoxide sensing devices as required by
Section 1317.2.3.
❑ Exception. Open parking garages.
21. Kitchen Hoods (Section 1317.11)
• Not Regulated. The plans /specs do not call for any new kitchen hoods with exhaust capacity
greater than 5,000 cfm each.
❑ Complies. All new kitchen hoods with a total exhaust capacity greater than 5,000 cfm have at
least 50 percent of the required makeup air; (a) unheated or heated to no more than 60 °F; and (b)
uncooled or evaporatively cooled.
e� The plans /specs show compliance in the following locations:
22. Outside Heating Systems (Section 1317.12)
❑ No Outside Heating Systems. The plans /specs do not call for new permanently installed heating
systems outside the building.
❑ Complies. All new permanently installed outside heating systems are radiant gas fired systems
controlled by an occupancy sensor or timer switch as required by Section 1317.12.
4 -6
- Compliance with OSSC, effective 04/01/07
Form 5a Project Name VAN'S - TIGARD. OR 1
LIGHTING - GENERAL REcEivEar
• 1. Interior Exceptions (Section 1313.1) DEC O 9. 009
❑ No Interior Lighting. The building plans and speciftcatygr Ti I�fgrfr9e•N or altered interior lighting.
Skip to item 5. Exterior building Lighting - General, bet VV ll7]1I11RflUJ
Exceptions ❑ Exceptions. 1 The building or part of the building 43111121DINGeWilp n code lighting
Discussion of qualifying requirements Applicable code exception is number.
exceptions in instructions ,
section 2 Lighting equipment that qualifies for an exception - in addition to general lighting and is separately
controlled. Applicable code exception is number
Areas of the building and equipment that qualify for any exceptions
Plans /Specs
Show compliance by including •
a drawing sheet, detail
number, and/or specification
section and subparagraph 2. Local Shut -off controls (Section 1313.3.1.1)
g Complies. At least one local shut -off lighting control for every 2,000 square feet of
lighted floor area and for all spaces enclosed by walls or ceiling height partitions
This control is detailed in the building plans on drawing number E1.1
❑ Exception. The building or part of the building qualifies for an exception
Applicable code exception is Section 1313.3 1 1, Exception
Portions of the building that qualify.
3. Automatic Shutoff Controls (Section 1313.3.1.2)
O Not Applicable. Office floor area is not over 2,000 square feet of contiguous office floor area or
permitted space is not over 5,000 square feet. No offices less than 300 square feet. meeting
or conference rooms, or school classrooms
❑ Complies All intenor lighting systems are equipped with a separate automatic control to shut off lighting
dunng unoccupied penods. Offices less than 300 square feet, meeting and conference rooms, and school
classrooms are equipped with occupancy sensors that comply with Section 1313 3 1.2 1
Compliance details in plans /specs:
❑ Exception. The building or part of the building qualifies for an exception
Applicable code exception is Section 1313 3 1,2. Exception'
Portions of the building that qualify
4. Daylighting Controls (1313.3.1.3)
O No classrooms or atriums with skylights or window to wall ratio greater than 50 %.
❑ Complies. All classrooms and atriums with window to wall ratio greater than 50% and /or skylights are
equipped with automatic daylight sensing controls, as required by Section 1313 3.1 3.1 and Section
1313.3.1.3.2 The daylight sensors specified comply with Section 1313.3.1 3.3
Compliance details in plans /specs'
Exterior Build 5. Exterior Lighting (Section 1313.5)
ing Lighting El Complies. The plans do not call for use of incandescent or mercury vapor lamps for use on building exterior
is lighting directed to ❑ Exception. The building plans Indicate luminaires with incandescent or mercury vapor lamps. but are
illuminate the exterior of the specified for use in or around swimming pools, water features, or other locations subject to requirements
building and adjacent of Article 680 of the 2002 National Electncal Code
walkways and loading areas
with or without canopies
• Clock Switches 6. Exterior and Canopy Lighting Controls (Section 1313.3.2)
shall be astronomic (seasonal O Complies. The building plans and specifications include photoelectnc and /or clock switches on all extenor
correcting) type with seoarate lighting systems which are designed and programmed to extinguish lights when daylight is present, as
• programs for each day of the required by Section 1313.3.2
week and shall store energy
to maintain timekeeping
during power outages
7. Connected Lighting Power (Section 1313.4) , PRo oF s
YES Complies The lighting power does not exceed the power allowance established b � NGI NE-,.. S
in either the Tenant Space Method (Form 5b) or the Space -by -Space Method (Form 5c). l(I i
���Y .dam r Tenant Space Method (Form 5b) Space -by -Space Method (Form 5c) ¢ $3363PE y r
� Q , l' '1�.yc; P OREGON co
F-; b: �1 -..-- l io1 q D O
i 3 Zt Z
t • .� '�0s 41 90A e• , �
"., !8-15 o� ' .
9
1 5 -t
1 V2 4 3 . Compliance with 2007 OSSC
Form 5c Project Name:IVAN'S - TIGARD, OR Page 2
INTERIOR LIGHTING POWER - Space -by -Space Method
Lighting
1. Total Interior Lighting Power Budget from Worksheet 5b - 1 (Sum of Column (I)) 4,949
Power Budget
2 Total length of track lighting (ft) 12
Track Lighting
Power 3 Line 2 multiplied by 50 Watts /ft 600
4. Total amperage of circuit breaker(s) serving track lighting (amps) -
5. Voltage of circuit breaker serving track lighting (volts) -
6. Maximum wattage of track lighting (multiply line 4 by line 5)
7. VA rating of the inline current limiter or the low voltage transformers -
8. Track Lighting Power (the lesser value of line 3. 6 or 7)
Building's 9 Total Interior Lighting Power from Worksheet 5b -1 (Sum of Column (m)) + 3,708
Interior 10. Total Adjusted Lighting Power (line 8 + line 9) = 3,708
Lighting Power
11. Does Interior Lighting Design Meet Budget? Line 10 must be no greater than line 1 YES
Exterior Canopy
Parking Garage 12. Do Exterior Canopies Meet Budget (Worksheets 5c)? N/A
Lighting Power 13. Does Parking Garage Meet Budget (Worksheets 5c)? N/A
14 Does Each Space With Retail Display Lighting Meet Budget (Worksheets 5d)? YES
Retail Display
Lighting Power 15 Is The Total Retail Display Lighting Additional Power Less Than 17,500 W (sum of line 9 on Worksheets 5d) YES
16. Does Retail Display Lighting Meet Budget? YES
r "i3
•
5 -3
Compliance with OSSC. effective 01/01/05
Work; • Project Name VAN'S - TIGARD, OR Page I 3
LIGHTING FIXTURE SCHEDULE (see Table 5c in instructions for default luminaire power).
. (a) (b) (c) (d) (e) (f)
Lum Luminaire Is Luminaire
ID Luminaire Lamp Ballasts Power From
Type 1 Description No Descnption No Descnption (watts) Table 5c
A I Track Lighting j Track Lighting - - - - - 50 YES
D I High Intensity Discharge - Metal Halide 1 -M100- ELECT -110W A 1 M100 1 Electronic 110 YES
B ! High Intensity Discharge - Metal Halide J 1-M100-ELECT-110W J 1 M100 1 Electronic 110 YES
C1 ! Compact Fluorescent Tnple 1- CFTR26W /GX24q -3- ELECT -28W J ( 1 CFTR26W /GX24q -3 1 Electronic 28 YES
F8 !Fluorescent 78 - 4 foot _� 2- F3278/30ES•ELECT NO-54W - 2 F32T8/30ES 1 Electronic Normal Output IS 54 YES
F8(E Fluorescent T8 - 4 foot A 2- F32T8f30ES -ELECT NO-54W - 2 F32T8/30ES 1 Electronic Normal Output IS 54 YES
F4 I Fluorescent 78 - 4 foot -( 1- F32T8/30ES -ELECT NO-29W - 1 F32T8P30ES 1 Electronic Normal Output IS 29 YES
F4(EM Fluorescent T8 - 4 foot 211 1- F32T8/30ES -ELECT NO-29W J 1 F32T8/30ES 1 Electronic Normal Output IS 29 YES
K 112 Volt Tungsten Halogen Lamps J 1 -35 watt lamp- EPS -38W • 1 35 watt lamp 1 Electronic Power Supply 38 YES
J A
I J J
jj - I 1 -
-
i J J
I J - -
J _ J
■ : -
I
� - = -1 - -
A - _ I
■ J
-( _I
J
J J - -
! �t �- -
1 — —
I A J — —
-I Ll -
. i - -
A
:1 J .:1--- -- �- -
J J - -
! J J
A
J J
. - -
- I : J
J J
J
I .1
V2 4 1 - Compliance with 2007 OSSC
Worksheet 5b-1 Project Name VANS - TIGARD, OR Page 4
INTERIOR LIGHTING POWER
Space -by -Space Method Only
Skip to column (f) if using the Tenant Space Method
(a) (b) (c) (d) (e) Lumf) ID (9) (h) (I) 0) (k)
L from Quantity of
Room ID (do Space Type Space Lighting Power Worksheet Luminaires (or Luminaire Lighting Room
not leave any Area (Table 13 -H) Type Budget 5a Column lineal ft for track Power Exempt Power Total Ltg
blanks) (ft') (enter space type only once per room) LPD (b) x (d) ( lighting) (Watts) Fixtures (g) x (h) Power
Each room 103 88 Comdor/Transition 0 5 44 C1 1 3 28 ❑ 84 84
must be 104 187 Comdorrrransition 05 94 F8 -I 1 54 ❑ 54 162
identified. 104 - - F8(EM) -I 2 54 ❑ 108 --
Describe
luminaires for each 101,102 76 Dressing /Locker /Fitting Room 06 46 K _ i 3 38 ❑ 114 114
individual room in 100 2018 Retail - Other Merchandise Sales Area 2 4,036 B _I
i 1 110 ❑ 110 3 462
plans
100 -- - D 24 110 ❑ 2,640 -
100 - - A 12 50 ❑ 600 -
100 - - C1 -I 4 28 ❑ 112 -
For track lighting 107 912 Active Storage 0 8 730 F8 -i 6 54 ❑ 324 486
enter lineal feet in 107 - _ F8(EM) -1 3 54 ❑ 162 -
column column (g) -
- - 1 _ - ❑ - -
Column (k), enter - -- -i - ❑ -
sum of column 0) - -- - l - ❑ - -
for each room only - _ - -' I ❑ - -
once at first entry
for the room See - - _ - i - ❑ - -
example in
i - - -! - ❑ - -
instructions
- -- - I - ❑ - -
- - J ❑ - -
- - I - ❑ - -
- - -! - ❑ - -
- - - I - ❑ - -
- - - 1 - ❑ - -
- - :1 - ❑ - -
- - - ❑ - -
- - - I ❑ - -
- - - 1 - ❑ - -
- -- - ❑ - --
- - - ❑ - - I
- -- -1 - ❑ - -
- ■ ! - ❑ - -
- - -! - ❑ - -
- - -) - ❑ - -
- 1 - ❑ - -
- - L I - ❑ - -
- - -I - ❑ - -
- - J - ❑ - -
- - -1 - ❑ - -
- - -i - ❑ - -
- -- -i - ❑ - -
- - -I - ❑ - -
- - - ❑ - -
- - -i - ❑ - -
3,281 Worksheet 5b -1 Total Budget 4,949 Wksht 5b -1 Total Lighting Power (excluding exempt/track fixtures) 3,708
•
Other Pages Total Number of Additional Worksheet 55 ; 0 _I
List the additional
worksheets nece-
ssary to catalog all - - -
luminaires in (I) (m) (n)
building Lighting Power Budget Space Proposed Buiding Lighting
by -Space only (Total of Power (Total of column (k), Area Sqft (not required
Worksheet Number column (e)) excluding exempt/track) for Tenant Method)
5b -1 4,949 3,708 3.281
5b -2 -
5b-3 -
Sum of additional 5b worksheets -
/'OI c
( •'� "'. Total Budget (of all worksheets) 4,848 3,708 3,281
; N+? ` o. 0 ,
\ \ ` r
�. 1
-.145
5 -5
V2 4 1 • Compliance with 2007 OSSC
• Worksheet 5d -1 Project Name. VANS - TIGARD. OR Page 5
Retail Display Lighting Power
Complete one worksheet for each room (space) for retail display lighting tnat is specifically
directed to highlight merchandise, and is controlled separately from the general lighting
system within the room General lighting should be included on Worksheet 5b
1. Room # or Space ID 100
2. Room Area (ft') 2018
3. Retail Space Type Retail - Other Merchandise Sales Al
(a)
Lum ID (b) (c) (d)
from Quantity of
Worksheet Luminaires (or Luminaire Lighting
5a Column lineal ft for track Power Power
Descnbe (a) lighting) (Warts) (0) x (C)
Luminaires for A 100 50 5,000
each individual
-
room in plans
•
For track lighting I _
enter lineal feet
in column (b) - -
•
1 Space Display Lighting Power (total d column excluding track fixtures) 0
2 Total length of track lighting (ft) 100
3 Line 2 multiplied by 50 Watts(ft 5000
4 Total amperage of circuit breaker(s) serving track lighting (amps) 20
5 Voltage of circuit breaker serving track lighting (volts) 120
6 Mawmum wattage of track lighting (multiply line 4 by line 5) 2400
i VA rating of the inline current limiter or the low voltage transformers
8 Track Lighting Power (the lesser value of line 3, 6 or 7) 2400
g Total Space Display Lighting Power (Watts) (line 1 + line 8) 2400
10 Total Space Display Lighting Power Budget (Watts) (room area x 1 75 to max 3531 5
of 17.500)
11 Does Space Retail Display Meet Space Budget (Line 9 less than line 10
and less than 17,500 W)7 YES
Total Number of Additional Worksheet 5d D -I