Loading...
Specifications / EC - 0 20/0— otJO3(, • • Form 4a Project Name: VAN'S - TIGARG OF page: 1 SYSTEMS - GENERAL Applicability ' ` P tans; Spas' Discussion of qualifying $110w compliance by inc! i Vng e.clrawin sh et cata{ ber, exceptions on page 4 -25 specification section and subparagraph�EL 0 . L 1. Applicablity (Section 1317) Is this form required? CITY OF TIGARU • El Form Required. Complete form if a new HVAC system is ;Dein.q iri3tallod; o comp i f nn l or Q NISION existing HVAC system are being replaced (I.e., equipment, controls, ductwork, and insulation.) ❑ Exception. The building or part of the building qualifies for an exception from HVAC code requirements. Applicable code exception is Section 1317.1. Portions of the building that qualify: Area: Exception ❑ -1 ❑ -2 ❑ -3 Area: Exception ❑ -1 ❑ -2 ❑ -3 Area: Exception ❑ -1 ❑ -2 ❑ -3 ❑ Form Not Required. This project does not contain work required to comply with code. 2. Simple or Complex Systems (Section 1317.9 or 1317.10) El Simple System. Building contains only Simple HVAC System(s). Complete this form (4a) and equipment efficiency worksheets as required. Form 4b is not required. ❑ Complex System. Project includes a Complex System. Complete this form (4a), form 4b and equipment efficiency worksheets as required. 3. Equipment Performance (Section 1317.5) ❑ No New HVAC Equipment. The building plans do not call for new electrical HVAC equipment, combustion heating equipment, or heat - operated cooling equipment. El Complies. All new HVAC equipment have efficiencies not less than those required by code. The following equipment efficiency worksheets are attached: 0-4a ❑ -4b ❑-4c 0 -4d 0 -4e 0 -4f 0 -49 0 -4h 0 -4i 0 -4. 4. Duct Insulation and Sealing (Sections 1317.7 & 1317.8) ❑ No Ducts. The building plans and specifications do not call for new HVAC ducts or plenums. o Complies. The plans and specifications call for all air - handling ducts and plenums to be insulated and sealed as reauired by Sections 1317.7 &1317.8. • 5. Distribution Transformers (Section 1316.1) o No Distribution Transformers. The plans /specs do not call for new distribution transformers. ❑ Complies. All new distribution transformers comply with efficiency, testing, and labeling requirements of Section 1316.1.1. P RCF F ❑ Exception. The project qualifies for an exception per Section 1316.1.1, Exceptiion: ���' 4a�l NFF ; 4 i 0 - 1 0 - 2 0 - 3 0 - 4 0 - 5 0 - 6 0 - 7 0 - 8 0 - 9 0 - 1 0 0 - 1 0-12 0-13 0-14 83363PE Attach relevant documentation for appropriate exception. The plans /specs show comp umtGON (z, following locations: UR% is 1 1 4 -1 FrPIRES: JUN: . 21.1 Compliance with OSSC, effective 04/01/07 i! .1 Form 4a Project Name: VAN'S - TIGARD. GR . Page: 2 SYSTEMS - GENERAL 6. HVAC Controls (Section 1317.4) , 6.1 System Thermostat /Zone Controls; (Sertiori 1317.1.1: Complies. All new HVAC systems include at least ono. te,r,peratuie'control,oevke responding to • temperatures within the zones. ❑ Exception. HVAC system qualifies for an exception from zone control requirements. The applicable code exception is Section 1317.4.2, • - " Exceetion 0 -1. 2 Portions of the building that qualify: : The plans /specs show compliance in the following locations: 6:2 Off - hour Controls - Auto Setback or Shutdown (Section 1317.4.3) O Complies. Systems must have at least one of the following features: O Control Setback Complies. Each system is equipped with automatic control capable of reducing energy through control setback during periods of non -use or alternate use of spaces served. O Equipment Shutdown Complies. Each system is equipped with controls capable of reducing energy use through automatic shutdown during periods of non -use or alternate use of spaces. HVAC systems with equipment shutdown are equipped with at least one of the following: O Programmable controls (1317.4.3.1 (1)) ❑ Occupant sensor (1317.4.3.1 (2)) ❑ Interlocked to a security system (1317.4.3.1 (3)) O Manually activated timers with 2 -hour operation max (1317.4.3.1 (4)) ❑ Exception. The building qualifies for an exception to the requirement for automatic setback or shutdown controls. The applicable code exception is Section 1317.4.3 Exception 0-1 0-2 The plans /specs show compliance in the following locations: 6.3 Control Capabilities (Sec. 1317.4.2.1) O Complies. Zone thermostats are capable of being set to the temperatures described in Sec. 1317.4.2.1. Where used to control both heating and cooling, zone controls shall be capable of providing a temperature range or deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. ❑ Exception. The building qualifies for an exception to the deadband requirements The applicable code exception is Section 1317.4.2.1 Exception 0 -1 0-2 Portions of the building that qualify: The plans /specs show compliance in the following locations: M 6.4 Optimum Start Controls (Section 1317.4.3.2) Complies. Separate HVAC systems have controls capable of varying start-up time of system to just meet temperature set point at time of occupancy. ❑ Exception. HVAC systems have a design supply air capacity not exceeding 10,000 cfm. The plans /specs show compliance in the following locations: 6.5 Heat Pump Controls (Section 1317.4.4) O No Heat Pump. The plans /specs do not call for a new heat pump ❑ Complies. All new heat pumps equipped with supplementary heaters are controlled to minimize the use of supplemental heat as defined in Section 1317.4.4. :a The plans /specs show compliance in the following locations: �n Cy 4 -2 Compliance with OSSC, effective 04/01/07 Form 4a Project Name: VAN'S - TIGARD, C Page: _ 3 SYSTEMS - GENERAL • • •• • • 7. Economizer Cooling (Section 1317.3) ❑ No Cooling. The building plans do not call for a new system with mechanical cooling. ❑ Complies. Each new fan system has an air economizer capable of modulating outside -air and return -air dampers to provide up to 100 percent of the•deci supply ail as outside air. ❑ Exception At least one new fan system qualifies for an exception. Tie applicable code exception is Section 1317.3, Exception ❑ -' ❑ -2 ❑ ❑ -4 ❑ -5 X7.6 i 1,7 If Exception 3 is selected complete the following: (a) Total cooling capacity of exempt units (Btu /hr) (b) Total installed building cooling capacity (Btu /hr) ❑ Complies. Sum of exempt units rated at less than 54,000 Btu /hr is <240,000 Btu /hr or a/b < 0.10 (10% of total building cooling capacity). Unit Identifier of exempt units: The plans /specs show compliance in the following locations: M -1.1 8. Economizer Pressure Relief as Integration (Section 1317.3.1 and 1317.3.2) El No Economizers Required. Project does not contain a new fan system requiring economizers. ❑ Overpressurization Complies. The drawings specifically identify a pressure relief mechanism for each fan system that will relieve the extra air introduced by the economizer. ❑ Integration Complies. Economizer is capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. ❑ Exception. The applicable exception is Section 1317.3.2, Exception ❑ -1 ❑ -2 The plans /specs show compliance in the following locations: 9. Hot Gas Bypass (Section 1317.5) o No Hot Gas Bypass ❑ Complies. See allowable amount of hot gas bypass as a percentage of total cooling capacity in table below. Unit ID Rated Cooling Capacity Hot Gas Bypass Capacity Allowable Hot Gas Bypass . i Rated Cooling Capacity Max Hot Gas Bypass <240,000 Btu /hr 50% >240,000 Btu /hr 25% ❑ Exception. Unitary packaged system with cooling capacity no greater than 90,000 Btu /h 4 -3 Compliance with OSSC, effective 04 /01/07 Form 4a Project Name: VAN'S - TIGARD, OR Page: 4 SYSTEMS - GENERAL 10. Shutoff Dampers (1317.4.3.3) o Not Required. Shutoff dampers are not required on this project. ❑ Complies. Each outdoor air supply & exhaust system shall be equipped with motorized dampers. ❑ Exception. The building qualifies for an exception to he motor,zed damper requirement. The applicable code exception is Section 1317.4.3.3 Exception ❑ -1 ❑ -2 17 - ❑ - ❑ - ❑ - The plans /specs show compliance in the following locations: 10.1. Shutoff Damper Controls (Section 1317.4.3.3.1) El Complies. Outdoor air supply and exhaust systems shall be provided dampers that automatically shut when systems or spaces served are not in use or during building warm -up, cooldown, or setback. ❑ Complies. Stair and shaft vents are capable of being automatically closed during normal building operation and interlocked to open as required by fire and smoke detection systems. The plans /specs show compliance in the following locations: 10.2. Motorized Damper Leakage (1317.4.3.3.2) El Complies. Motorized outdoor air supply and exhaust air dampers have a maximum leakage rate of 4 cfm /ft2 at 1.0 in w.g. when tested in accordance with AMCA Standard 500 -1998. ❑ Exception. Packaged HVAC equipment may have maximum leakage rate of 20 cfm /ft at 1.0 in w.g. when tested in accordance with AMCA Standard 500 -1998. The plans /specs show compliance in the following locations: 11. Piping Insulation (Section 1314) El No New Piping. The building plans and specifications do not call for new piping serving a heating or cooling system or part of a circulating service water heating system. ❑ Complies. All new piping serving a heating or cooling system or part of a circulating service water heating system complies with the requirements of the Code, Section 1314.1. ❑ Exception. New piping qualifies for exception: Section 1314.1, Exception ❑ -1 ❑ -2 12. Occupancy Ventilation El Complies. Mechanical ventilation systems provide the required amount of ventilation is indicated in plans /specifications as specified in Chapter 4 of the Oregon Mechanical Specialty Code. ❑ Complies. Natural ventilation systems provide required amount of ventilation as certified by a reg- istered architect or engineer as specified by Section1203.4.1, Exception. Attach worksheet 4m. The plans /specs show compliance in the following locations: The plans /specs show compliance on the following pages: 4-4 Compliance with OSSC, effective 04 /01/07 Form 4a Project Name: VAN'S - TIGA:2C, OR Wage: 5 _ SYSTEMS - GENERAL . 13. High Occupancy Ventilation (Section 13;7.2.21 , : ` . El Complies. HVAC systems with ventilation air caps% ities of 1`,5('0 �FM.or grcat€r that serve areas having an average occupant load of 20 square feet par psmon or'less'from Table '1004.1.2 have a means to automatically reduce outside air intake. Identify applicable systems: . Plans /specs indicate where equipment (i.e. carbon dioxide "sen•or) ant 'ec•,uerce is specified: ❑ Exception. HVAC systems are equipped with an energy recovery device with at least 50% recovery effectiveness. ❑ No High Occupancy Systems. Project does not contain an HVAC system as described above. 14. Exhaust Air Heat Recovery (Section 1318.3) El Not Regulated. HVAC system does not have: 1) design supply air cap. of >10,000 cfm, and 2) min. outside air supply >70 %, and 3) at least 1 exhaust fan rated at 75% of min outside air supply. ❑ Complies. Heat recovery system increases outside air temperature by 20 °F (Climte Zone 1) or 30 °F (Zone 2) and has provision to provide bypass during air economizer mode. ❑ Exception. An HVAC system qualifies for an exception to this requirement. Applicable exception from Section 1318.3 Exception 0- 0-2 0-3 0-4 0-5 0-6 0-7 The plans /specs show compliance in the following locations: 15. Large Volume Fan Systems (Section 1318.4.2.4) El Not Regulated. The building plans or specifications do not call for fan systems over 15,000 CFM that serve a single zone and function for the purpose of temperature control. ❑ Complies. Fan systems are equipped with variable frequency drive or two speed motor to reduce airflow as required by Section 1318.4.2.3. The plans /specs show compliance in the following locations: 16. Variable Speed Drives (Section 1317.10.3.1) ❑ Not Regulated. The building plans or specifications do not call for fan and pump motors 10 horsepower and greater that serve variable -flow air or liquid systems. ❑ Complies. All fan and pump motors 10 hp and greater which serve variable -flow air or liquid systems are controlled by a variable -speed drive. ❑ Exception. The building qualifies for an exception to the variable -speed drive requirement. Portions of the building that qualify: Applicable code exception is Section 1317.10.3.1, Exception The plans /specs show compliance in the following locations: 17. Service Water Heating (Sec. 1315) El No New Water Heating. The building plans and specifications do not call for new water heaters, hot water storage tanks or service hot water distribution systems. ❑ Complies. All new water heaters, hot water storage tanks or service hot water distribution systems comply with the requirements of the Section 1315. ❑ Exception. The applicable code exception is Section: Exception: - fQ Portions of the building that qualify: t \, "r" The plans /specs show compliance in the following locations: 4 -5 Compliance with OSSC, effective 04 /01/07 . . Form 4a Project Name: VAN'S - TIGAR G, OR Page: 6 SYSTEMS - GENERAL • 18. Swimming Pools, Spas and Hot Tubs, (Section - 135.51: , • , o No New Pools. The building plans and specification not c3ll:'fcr' r•.ew, s,wimniing pools, spas or hot tubs. , , ❑ On /Off Controls Complies. Spa and hot tub heaters are equipped with a readily accessible ON /OFF switch as required by Section 1315.5.1. ❑ Ventilation Controls Complies. Pool ventilation system i.k ctintrd+led on humidity. ❑ Cover Complies. All heated pools, hot tubs and spas are. quipped wit: i a ewer. ❑ Heat Recovery Complies. Pools, Spas, and hot tubs, over 200 ft utilize recovered heat as required by Section 1315.5.3. ❑ Exception. Heat recovery is not necessary as pool is heated by renewable energy or waste heat recovery sources capable of providing at least 70 percent of the heating energy required over an operating season. 19. Fume Hoods (Section 1317.2.1.) El No Fume Hoods. The building plans do not call for fume hood systems that have a total exhaust rate greater than 15,000 cfm. ❑ Complies. Fume hood systems have at least one of the following features: ❑ Variable air volume hood exhaust and room supply systems capable of reducing exhaust and makeup air volume to 50% or less of design values. ❑ Direct makeup (auxiliary) air supply equal to at least 75% of the exhaust rate, heated no warmer than 2° F below room set point, cooled no cooler than 3° F above room set point, no humidification added, and no simultaneous heating and cooling used for dehumidification control. ❑ Heat recovery systems to precondition makeup air from fume hood exhaust in accordance with 1318.3 - Exhaust Air Energy Recovery, without using any exception. The plans /specs show compliance in the following locations: 20. Parking Garage Ventilation (Section 1317.2.3) El No Enclosed Garages. The building plans and specifications do not call for enclosed Group S -2 parking garages with a ventilation exhaust rate greater than 30,000 CFM. ❑ Complies. The plans and specifications call for carbon monoxide sensing devices as required by Section 1317.2.3. ❑ Exception. Open parking garages. 21. Kitchen Hoods (Section 1317.11) El Not Regulated. The plans /specs do not call for any new kitchen hoods with exhaust capacity greater than 5,000 cfm each. ❑ Complies. All new kitchen hoods with a total exhaust capacity greater than 5,000 cfm have at least 50 percent of the required makeup air; (a) unheated or heated to no more than 60 °F; and (b) uncooled or evaporatively cooled. rai The plans /specs show compliance in the following locations: 't 22. Outside Heating Systems (Section 1317.12) ❑ No Outside Heating Systems. The plans /specs do not call for new permanently installed heating systems outside the building. ❑ Complies. All new permanently installed outside heating systems are radiant gas fired systems controlled by an occupancy sensor or timer switch as required by Section 1317.12. 4 -6 Compliance with OSSC, effective 04/01/07 • Air System Design Load Summary for TOTAL FTU 2 Project Name: 0120093134 VANS ATTIGARD OR 12123/2009 Prepared by LBI 03:33PM ' DESIGN COOLING DESIGN•HEATING . ' COOLING.DATA AT Jun 1300 . HEATING DATAATDES HTG . . COOLING:OAMB / WB 86.6 °F./ 662°F HEATING'OA.DB f WB ;22'0 °F•/18.4 °F • . . • . • . • Sensible - latent • • ' Sensible . Latent - ZONE' LOADS Details (BTU/hr) - (BT.U/hr) .. • 'Details (BTU/hr) (BTUIhr) Window & Skylight Solar Loads 0 ft' 0 - 0 ft - - Wall Transmission 0 ft 0 - 0 ft 0 - Roof Transmission 3455 ft 9249 - 3455 ft 19993 - Window - Transmission 0 ft' 0 - 0 ft • 0 - Skylight Transmission 0 ft 0 - 0 ft 0 - Door Loads 0 ft 0 - 0 ft 0 - Floor Transmission 3440 ft 0 - 3440 ft 0 - Partitions 0 ft 0 - 0 ft 0 - Ceiling 0 ft 0 - 0 ft 0 - Overhead Ughting 322 W 653 - 0 0 - Task Ughting 6162 W 17853 - 0 0 - Electric Equipment 400 W 1273 - 0 0 - People - 38 6635 7881 0 0 0 . Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 25% 4998 0 .4 »7otal.Zone Loads . . ' 25663 • - 7881 - 24991 0 Zone Conditioning _ - 38697 7881 - 24229 0 Plenum Wall Load 0% 0 - 0 0 - -4 Plenum Roof Load 70% 21582 - 0 0 - Plenum Ughting Load 30% 330 - 0 0 - Return Fan Load 2179 CFM 0 - 22 CFM 0 - Ventilation Load 0 CFM 0 0 0 CFM 0 0 Supply Fan Load 2179 CFM 2589 - ' 22 CFM -569 - Space Fan Coll Fans - 0 - - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total` System.Loads • • - 63198 • 7881 - • 23661, 0 Central Cooling Coil - 63198 7882 - -773 0 Terminal Reheat Coils - 0 - - 24434 - »Total.'Condltioning• - -63198, '7882 • • • -I 23661 • • '.0 Key: , . - . ' - • .Positive values:are cig loads Positive values are°htg loads . 's Negativevaluesare loads 'Negative values .clg loads • • • Hourly Analysis Program v.4.4 Page 1 of 1 • [Page Too Large for OCR Processing] [Page Too Large for OCR Processing]