Specifications - - F orm 2a Project Name: Metzger Elem. Page: . 1 SUMMARY /O2SS /46C__9lp - 0-6'57 Project 1. Project 1 Metzger Elementary 2. Project Address 10255 SW 90th Ave. • 3. City/Town Ti gar d 5. County Washington 4. Building, Gross Area (ft 52,874 6. No. of floors 1 • Chapter Type ID Description Attached Attached Building Envelope Form 3a Building Envelope - General ❑ Forms and Worksheets 3b Prescriptive Path - Zone 1 ❑ 3c Prescriptive Path - Zone 2 ❑ Check boxes to 3d Simplified Trade -off ❑ indicate attached forms and Worksheet 3a Wall U- factors ❑ worksheets. 3b Roof U- factors ❑ 3c Floor U- factors ❑ Systems Form 4a Systems - General El 4b Complex Systems ❑ Worksheet 4a Unitary Air Conditioners - Air Cooled 4b Unitary Air Conditioners - Water Cooled ❑ 4c Unitary Heat Pump - Air Cooled ❑ 4d Unitary Heat Pump - Water Cooled ❑ 4e Unitary AC & Heat Pump - Evaporatively Cooled ❑ 4f Packaged Terminal Air Conditioner - Air Cooled ❑ 4g Packaged Terminal Heat Pump - Air Cooled ❑ 4h Water Chilling Packages - Water & Air Cooled ❑ 4i Boiler - Gas -fired & Oil -fired ❑ 4j Furnaces and Unit Heaters - Gas -fired & Oil -fired ❑ Lighting Form 5a Lighting - General ❑ 5b Interior Lighting Power - Occupancy Method ❑ 5c Interior Lighting Power - Space -by -Space Method ❑ Worksheet 5a Interior Lighting Power ❑ 5b Lighting Schedule ❑ 5c Interior Control Credits ❑ 7. Name Alan Kolkemo 10. Telephone (503) 654 -8422 8. Company Johnson Controls, Inc. 11 Date 9/4/96 9. Signature stict a-- 11-1.1914-ec.i.u No. of Pages Description of Document • 13 Product Data I ' (1 /96) Forms 2 -1 'Form 4a Project Name: Metzger Page: 2 SYSTEMS - GENERAL 1. Exceptions (Section 1313) ❑ No HVAC. The building plans do not call for an HVAC system. Skip to Item 12 below. Exceptions ❑ Exception. The building or part of the building P 9 P g qualifies for an exception from the code HVAC See a discussion of requirements. The applicable code exception is: Section 1313, Exception . Portions of the ▪ qualifying excep- building which qualify: lions on p. 4 -14 See p. 4-14 fora 2. Simple or Complex Systems (Section 1313.2) • discussion of simple i Simple System. The planned HVAC system qualifies as a Simple System. If true, complete this vs. crosplex form (4a) and equipment efficiency worksheets as required. Form 4b is not required. ❑ Complex System. The planned HVAC system is a Complex System. Complete this form (4a), Form 4b and equipment efficiency worksheets as required. Exceptions 3. Economizer Cooling (Section 1313.1.2) Complex Systems ❑ No Cooling. The building plans do not call for a new fan system with mechanical cooling. may cibnslallowed Com plies. The new fan system has an air economizer capable of modulating outside air and for Simple Systems, return dampers to provide up to 85 percent of the design supply air as outdoor air. plus three excep- ❑ Exception — Simple Systems. The new fan system qualifies for an exception. The applicable Lions allowed in code exception is: Section 1313.1.2, Exception , or Section 1313.2.1. Portions of the Section 1313.1.2. P P See p. 4 -15 fora building which qualify: discussion of these ❑ Exception — Complex Systems. The new fan system qualifies for an exception. The applicable exceptions. code exception is: Section.1313.1.2, Exception , or 1313.3.1, Exception _. Portions of the building which qualify: 4. Economizer Cooling — Overpressurizing (Section 1313.1.2) ❑ No Economizer. The building plans do not call for a new fan system with an economizer. 113 Complies. The drawings specifically identify a pressure relief mechanism for each fan system that will exhaust the extra air introduced by the economizer, and the economizer system is capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the load. 5. System and Zone Controls (Sec. 1313.1.3.1 as 1313.1.3.2) 3 Complies. All new HVAC systems include at least one temperature control device responding to tempreatures within the zone. ❑ Exception. The new HVAC system qualifies for an exception from the zone control require - Exceptions ments. The applicable code exception is: Section 1313.1.3.2, Exception 1 and 2. Portions of the See a discussion of building which qualify: qualifying excep- • tions on p. 4-16. 6. Control Capabilities (Sec. 1313.1.3.2.1) ® Complies. Zone thermostats are capable of being set to the temperatures described in Sec. 1313.1.3.2.1. Where used to control both heating and cooling, zone controls shall be capable of providing a temperature range or dead band of at least 5 degrees F within which the supply of ' heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions ❑ Exception. The building qualifies for an exception to the dead band requirements. The appli- See a discussion of cable code exception is: Section1313.1.3.2.1, Exception qualifying excep- . tions on p. 4 -16. (1/96) Forms & Worksheets 4 -1 Form•4a (cont.) Project Name: Metzger Elem. Page: 3 SYSTEMS - GENERAL 7. Off -hour Controls - HVAC Systems (Section 1313.1.3. ID Complies. All new HVAC systems are capable of automatic setback or shutdown during periods of non -use or alternate use of the space served by the system. ❑ Exception. Equipment has full load heating demands of 2 kW (6,826 Btu /hr) or less and is controlled by a readily accessible manual off -hour control. 8. Off - hour Controls — Supply and Exhaust Systems (1313.1.3.3) • Complies. Plans require that outdoor air supply and exhaust systems have a means of auto- matic (either motorized or gravity damnper) volume shutoff or reduction during periods of non- use or alternate use of the space served by the system. ❑ Exception. The building qualifies for an exception to the requirement for automatic shutoff or reduction. The applicable code exception is Section 1313.1.3.1, Exception 9. Heat Pump Controls (Section 1313..1.3.4) 5a No Heat Pump. The plans /specs do not call for a new heat pump. ❑ Complies. All new heat pumps equipped with supplementary heaters are controlled as required in Section 1313.1.3.4. 10. Equipment Performance (Section 1313.1.4) ❑ No New HVAC Equipment. The building plans do not call for new electrical HVAC equipment, combustion heating equipment or heat - operated cooling equipment. Complies. All new HVAC equipment has efficiencies not less than those required by the code. The following equipment efficiency worksheets are attached 4a 11. Duct Insulation (Section 1313.2.2 & 1313.3.2) ❑ No Ducts. The building plans/specs do not call for new HVAC ducts or plenums. ID Simple System: Complies. The plans/specs call for a Simple System, and all exterior supply/ return air - handling ducts and plenums and all outside air ducts are insulated as required by Sec. 1313.2.2. ❑ Complex System: Complies. The building plans /specs call for a Complex System, and all air - handling ducts and plenums are insulated as required by Sec. 1313.3.2. 12. Piping Insulation (Section 1314) Exceptions ❑ No New Piping. The building plans /specs do not call for new piping serving a heating or cooling system or part of a circulating service water heating system. See a discussion of qualifying ❑ Complies. All new piping serving a heating or cooling system or part of a circulating service dees s on excep- p. 4-17. water heating system complies with the requirements of the Code, Section 1314.1. ❑ Exception. New piping qualifies for the following exception: Section 1314, Exception . 13. Service Water Heating (Section 1315) 0 No New Water Heating. The building plans /specs do not call for new water heaters, hot water storage tanks, service hot water distribution systems, swimming pools or spas. Exceptions ❑ Complies. All new water heaters, hot water storage tanks, service hot water distribution sys- See a discussion of tems, swimming pools or spas comply with the requirements of the Code. qualifying excep- ❑ Exception. The applicable code exception is, Section , Exception . Portions lions on p 4 -18. of the building which qualify: 4 -2 Systems (1 /96) Worksheet 4a rrofect lame: Metzger Elementary uay ° .. 4 _ • UNITARY AIR CONDITIONER -..AIR. COOLED .. Equipment ( (b) (c) (d) (e) See p. 4 -19 fora Proposed discussion of Performance equipment ratings Cooling Seasonal Compliance and equipment Capacity Steady or Part Schedule definitions. Equip. ID Model Designation (Btu /h) State Load (A -E) RT -11 D3CG090N16525EC 96.900 8.90 9.60 C . RT -12 D3CG090N16525EC 94,800 8.90 9.60 C RT -13 D2EG060N09925EB 63,800 11.00 C RT -14 D6CG036N07925EC 40,500 10.10 C RT -15 D6CG036N07925EC 40,500 10.10 C RT -16 D6CG036N07925EC 40.500 10.10 C RT -17 D6CG036N07925EC 40,500 10.10 C RT -18 D6CG036N07925EC 40,500 10.10 C RT -19 D6CG036N07925EC 40,500 10.10 C RT -20 D6CG036N07925EC 40,500 10.10 C 1. Does the proposed equipment meet the required equipment efficiency? Enter "Y" if yes. Y 2. Check boxes to indicate the source of information: ❑ ARI Unitary Directory, Section AC (Enter the page number) ❑ ARI Applied Products Directory, Section ULE (Enter the page number: 9_ Product data (Attach data furnished by the equipment supplier) Cooling Capacity (Btu /h) Minimum Rating Compli- ance But not Steady Seasonal or Schedule Equipment Type Over • over - State Part Load Single Package 0 65,000 na 9.7 SEER A Without a 65,000 135,000 8.9 EER 8.3 IPLV Heating Section 135,000 760,000 8.5 EER 7.5 ILPV 760,000 - 8.2 EER 7.5 IPLV Split System 0 65,000 na 10.0 SEER B Without a 65,000 135,000 8.9 EER 8.3 IPLV • Heating Section 135,000 760,000 8.5 EER 7.5 IPLV 760,000 - 8.2 EER 7.3 IPLV Single Package 0 65,000 na 9.7 SEER C With a 65,000 135,000 8.9 EER 8.3 IPLV Heating Section 135,000 760,000 8.3 EER 7.3 IPLV 760,000 - 8.0 EER 7.3 IPLV Split System 0 65,000 na 10.0 SEER D With a 65,000 135,000 8.9 EER 8.3 IPLV Heating Section 135,000 760,000 8.3 EER 7.3 IPLV 760,000 - 8.0 EER 7.3 IPLV E Condensing Unit Only 135,000 _ - 9.9 EER 11.0 IPLV -- 4-4 Systems (1/96) Worksheet 4a rrolect Name: Metzger •Elem. ' • u"'" y c ) UNITARY AIR CONDITIONER - AIR • COOLED Equipment ( (b) (c) - (d) (e) .t- See p. 4 -19 fora Proposed discussion of Performance equipment ratings Cooling Seasonal Compliance and equipment Capacity Steady or Part Schedule ' definitions. Equip. ID Model Designation (Btu /h) State Load (A -E) L RT -21 D6CG036N07925EC 40,500 10.10 C RT -22 D6CG036N07925EC 40,500 10.10 C • • 1. Does the proposed equipment meet the required equipment efficiency? Enter "Y" if yes. Y 2. Check boxes to indicate the source of information: . ❑ ARI Unitary Directory, Section AC (Enter the page number) I ❑ ARI Applied Products Directory, Section ULE (Enter the page number) ❑ Product data (Attach data furnished by the equipment supplier) Cooling Capacity (Btu /h) Minimum Rating Compli- ance But not Steady Seasonal or Schedule Equipment Type Over over - State Part Load Single Package 0 65,000 na 9.7 SEER A Without a 65,000 135,000 8.9 EER 8.3 IPLV Heating Section 135,000 760,000 8.5 EER 7.5 ILPV 760,000 - 8.2 EER 7.5 IPLV Split System 0 65,000 na 10.0 SEER B • Without a 65,000 135,000 8.9 EER 8.3 IPLV Heating Section 135,000 760,000 8.5 EER 7.5 IPLV 760,000 - 8.2 EER 7.3 IPLV ' Single Package 0 65,000 na 9.7 SEER • C With a 65,000 135,000 8.9 EER 8.3 IPLV Heating Section 135,000 760,000 8.3 EER 7.3 IPLV 760,000 - 8.0 EER 7.3 IPLV r Split System 0 65,000 na 10.0 SEER 0 With a 65,000 135,000 8.9 EER 8.3 IPLV Heating Section 135,000 760,000 8.3 EER 7.3 IPLV 760,000 - 8.0 EER 7.3 IPLV • E Condensing Unit Only _ 135,000 _ - 9.9 EER 11.0 IPLV 4 -4 Systems (1/96) • -. WORK WORK ENGINEER'S REPORT Date 02/20/96 Page 20 GAS/ELECTRIC ROOFTOP UNIT • Order No Job Name Tigard School District Engineer Architect Submitted By Alan Kolkemo . QUANTITY: 1 Schedule No: RT -11 Music/lnstr. Model No: D3CGO9ON16525EC - COOLING PERFORMANCE HEATING PERFORMANCE - Entering Air Temp. 50.0 F Total Capacity* 96.9 MBH Leaving Air Temp. 100.9 F Sensible Capacity 52.1 MBH Air Temp. Rise 50.9 F Efficiency (at ARI) 8.90 EER Electric Heat Part Load Efficiency 9.6 IPLV Capacity N/A MBH Power Input N/A KW Power Input (w /o blower) 8.26 KW Elevation 300 Ft Leaving DB Temp 58.93 F Gas Heat Leaving WB Temp Gas Fired Input 204 MBH Gas Fired Output 163 MBH N/A N/A Steady State Efficiency 79.0 % Outdoor DB Temp 90.0 F Heat Pump Entering DB Temp 75.0 F Capacity: 47F N/A MBH Entering WB Temp 67.0 F 17F N/A MBH 'Gross Capacity COP: 47F N/A 17F N/A SUPPLY AIR BLOWER PERFORMANCE HSPF N/A Total Supply Air 3000 CFM .4 Indicates Heating Performance Type Outside Air 600 CFM ELECTRICAL DATA External Static Pressure 0.75 IWG - Duct Location Bottom Single Package Blower Speed 1138 RPM Power Supply 230 -3-60 Motor Rating 2.0 HP Total Unit Ampacity 43.8 Amps Power Input Requirement 1.71 KW Maximum Overcurrent Device Brake Horsepower 1.83 BHP Fuse Size 50 Amps Indoor Fan Motor Heat 5.8 MBH HACR Breaker Size 50 Amps Minimum Wire Size 8 AWG(75 C) PACKAGE UNIT CLEARANCES APPROXIMATE DIMENSIONS & WEIGHT* Front 24 in Back 36 in PACKAGE UNITS Bottom 0 in Top 72 in Left Side (filter access) 54 in Height 34 in Width 10 In Depth 71 in ' Right Side (outdoor 24 in Total Weight fund factory options) 1177 Lbs* INDOOR UNIT CLEARANCES SPLIT SYSTEMS in Side With RETURN AIR opening in Outdoor Unit: Height in Width in Depth Side With SUPPLY AIR opening in Outdoor Unit Total Weight Lbs Side With PIPING CONNECTIONS in Indoor Unit:Height in Width in Depth in Side Opposite PIPING CONN. in Intdoor Unit Total Weight 0 Lbs • Rigging Weight . Engineer's Notes: NOTE: Check Local Codes CORK ENGINEER'S REPORT Date 02/20/96 Page 21 Rearm end Air Cordtioning GAS /ELECTRIC ROOFTOP UNIT Order No Job Name Tigard School District Engineer • Architect Submitted By Alan Kolkemo QUANTITY: 1 Schedule No: RT -12 Library Model No: D3CG090N16525EC . . COOLING PERFORMANCE HEATING PERFORMANCE Entering Air Temp. 50.0 F N. Total Capacity' 94.8 MBH Leaving Air Temp. 104.6 F Sensible Capacity 50.3 MBH Air Temp. Rise 54.6 F Efficiency (at ARI) 8.90 EER Electric Capac N/A MBH Part Load Efficiency 9.6 IPLV Power Input (w /o blower) 8.26 KW Power Input N/A KW Elevation 300 Ft Leaving DB Temp 58.37 F Leaving WB Temp 56.40 F 4 Gas Heat Gas Fired Input 204 MBH Gas Fired Output 163 MBH N/A N/A Steady State Efficiency 79.0 % Outdoor DB Temp 90.0 F Heat Pump Entering DB Temp 75.0 F Capacity: 47F N/A MBH Entering WB Temp 67.0 F 17F N/A MBH *Gross capacity COP: 47F N/A 17F N/A SUPPLY AIR BLOWER PERFORMANCE HSPF N/A Total Supply Air 2800 CFM 4 indicates Heating Performance Type Outside Air 600 CFM ELECTRICAL DATA External Static Pressure 0.75 IWG Duct Location Bottom Single Package Blower Speed 1096 RPM Power Supply 230 -3-60 Motor Rating 2.0 HP Total Unit Ampacity 43.8 Amps Power Input Requirement 1.51 KW Maximum Overcurrent Device Brake Horsepower 1.61 BHP Fuse Size 50 Amps Indoor Fan Motor Heat 5.2 MBH HACR Breaker Size 50 Amps Minimum Wire Size 8 AWG(75 C) PACKAGE UNIT CLEARANCES APPROXIMATE DIMENSIONS & WEIGHT* Front 24 in Back 36 in PACKAGE UNITS Bottom 0 in Top 72 in Left Side (filter access) 54 in Height 34 in Width 10 in Depth 71 in • Right Side (outdoor 24 in Total Weight (incl factory options) 1177 Lbs* INDOOR UNIT CLEARANCES SPLIT SYSTEMS in Side With RETURN AIR opening in Outdoor Unit:Height in Width in Depth Side With SUPPLY AIR opening in Outdoor Unit Total Weight Lbs Side With PIPING CONNECTIONS in Indoor Unit:Height in Width in Depth in Side Opposite PIPING CONN. in Intdoor Unit Total Weight 0 Lbs • Rigging Weight Engineer's Notes: NOTE: Check Local Codes • RAC ENGINEER'S REPORT Date 02/20/96 Page 22 Rearm and Air Cordionirta HIGH EFFICIENCY GAS /ELECTRIC ROOFTOP UNIT Order No Job Name Tigard School District Engineer Architect Submitted By Alan Kolkemo QUANTITY: 1 Schedule No: RT -13 Office Model No: D2EG060N09925EB . . COOLING PERFORMANCE HEATING PERFORMANCE Entering Air Temp. 50.0 F .1 Total Capacity' 63.8 MBH Leaving Air Temp. 95.8 F Sensible Capacity 33.6 MBH Air Temp. Rise 45.8 F Efficiency (at ARI) 11.00SEER Electric Heat Part Load Efficiency 0.0 IPLV Capacity N/A MBH Power Input N/A KW Power Input (w /o blower) 4.70 KW Elevation 300 Ft Leaving DB Temp 59.45 F Leaving WB Temp 57.09 F 4 Gas Heat Gas Fired Input 125 MBH Gas Fired Output 99 MBH N/A N/A AFUE 80.3 Outdoor DB Temp 90.0 F Heat Pump Entering DB Temp 75.0 F Capacity: 47F N/A MBH Entering WB Temp 67.0 F 17F N/A MBH *Gross capacity COP: 47F N/A 17F N/A SUPPLY AIR BLOWER PERFORMANCE HSPF N/A Total Supply Air 2000 CFM 4 Inolcates Heating Performance Type Outside Air 400 CFM ELECTRICAL DATA External Static Pressure 0.75 IWG Duct Location Bottom Single Package Blower Speed 1137 RPM Power Supply 230 -3-60 Motor Rating 1.0 HP Total Unit Ampacity 32.4 Amps Power Input Requirement 1.34 KW Maximum Overcurrent Device Fuse Size 50 Amps Indoor Fan Motor Heat 4.6 MBH HACR Breaker Size 50 Amps Minimum Wire Size 8 AWG(60 C) PACKAGE UNIT CLEARANCES APPROXIMATE DIMENSIONS & WEIGHT' Front 32 in Back 36 in PACKAGE UNITS Bottom 0 in Top 72 in Height 33 in Width 82 in Depth 45 in Left Side (filter access) 36 in Right Side (outdoor 24 in Total Weight (incl factory options) 740 Lbs" INDOOR UNIT CLEARANCES SPLIT SYSTEMS in Side With RETURN AIR opening in Outdoor Unit: Height in Width in Depth Side With SUPPLY AIR opening in Outdoor Unit Total Weight Lbs Side With PIPING CONNECTIONS in Indoor Unit:Height in Width in Depth in Side Opposite PIPING CONN. in Intdoor Unit Total Weight 0 Lbs • Rigging Weight Engineer's Notes: NOTE: Check Local Codes .IYORIC ENGINEER'S REPORT Date 02/20/96 Page 11 tt�and re GAS/ELECTRIC ROOFTOP UNIT Order No Job Name Tigard School District Engineer Architect Submitted By Alan Kolkemo QUANTITY: 1 Schedule No: RT -14 CR 1 Model No: D6CG036N07925EC COOLING PERFORMANCE HEATING PERFORMANCE Entering Air Temp. 50.0 F - • Total Capacity' 40.5 MBH Leaving Air Temp. 111.0 F Sensible Capacity 20.9 MBH Air Temp. Rise 61.0 F 1 Efficiency (at ARI) 10.10 SEER Electric Heat Part Load Efficiency 0.0 IPLV Capacity N/A MBH Power Input N/A KW Power Input (w /o blower) 3.31 KW Elevation 300 Ft Leaving DB Temp 58.89 ,89 F Gas Heat Leaving WB Temp Gas Fired Input 100 MBH Gas Fired Output 79 MBH N/A N/A AFUE 80.5 Outdoor DB Temp 90.0 F 'Heat Pump Entering DB Temp 75.0 F Capacity: 47F N/A MBH Entering WB Temp 67.0 F _ 17F N/A MBH *Gross Capacity COP: 47F N/A 17F N/A SUPPLY AIR BLOWER PERFORMANCE HSPF N/A Total Supply Air 1200 CFM + Indicates Healing Performance Type Outside Air 600 CFM ELECTRICAL DATA External Static Pressure 0.83 IWG Duct Location Bottom Single Package Blower Speed High Power Supply 230 -3-60 Motor Rating 0.5 HP Total Unit Ampacity 24.3 Amps Power Input Requirement 0.66 KW Maximum Overcurrent Device Fuse Size 35 Amps Indoor Fan Motor Heat 2.3 MBH HACR Breaker Size 35 Amps Minimum Wire Size 10 AWG(60 C) PACKAGE UNIT CLEARANCES APPROXIMATE DIMENSIONS & WEIGHT" Front 32 in Back 36 in PACKAGE UNITS Bottom 0 in Top 72 in Left Side (filter access) 36 in Height 33 in Width 82 in Depth 45 in Right Side (outdoor 24 in Total Weight (ind factory options) 665 Lbs* INDOOR UNIT CLEARANCES SPLIT SYSTEMS in Side With RETURN AIR opening in Outdoor Unit:Height in Width in Depth Side With SUPPLY AIR opening in Outdoor Unit Total Weight Lbs Side With PIPING CONNECTIONS in Indoor Unit:Height in Width in Depth in Side Opposite PIPING CONN. in Intdoor Unit Total Weight 0 Lbs • Rigging Weight Engineer's Notes: NOTE: Check Local Codes . WORK' ENGINEER'S REPORT Date 02/20/96 Page 12 and Air Cordtioning GAS/ELECTRIC ROOFTOP UNIT Order No Job Name Tigard School District Engineer Architect Submitted By Alan Kolkemo QUANTITY: 1 Schedule No: RT -15 CR 2 Model No: D6CG036N07925EC COOLING PERFORMANCE HEATING PERFORMANCE Entering Air Temp. 50.0 F . Total Capacity' 40.5 MBH Leaving Air Temp. 111.0 F Sensible Capacity 20.9 MBH Air Temp. Rise 61.0 F Efficiency (at ARI) 10.10 SEER Electric Heat Part Load Efficiency 0.0 IPLV Capacity N/A MBH Power Input N/A KW Power Input (w /o blower) 3.31 KW Elevation 300 Ft Leaving DB Temp 58.89 F Leaving WB Temp 56.43 F 4 Gas Heat Gas Fired Input 100 MBH Gas Fired Output 79 MBH N/A N/A AFUE 80.5 % Outdoor DB Temp 90.0 F _Heat Pump Entering DB Temp 75.0 F Capacity: 47F N/A MBH Entering WB Temp 67.0 F 17F N/A MBH *Gross capacity COP: 47F N/A 17F N/A SUPPLY AIR BLOWER PERFORMANCE HSPF N/A Total Supply Air 1200 CFM 4 Indicates Heating Performance Type Outside Air 600 CFM ELECTRICAL DATA External Static Pressure 0.83 IWG Duct Location Bottom Single Package Blower Speed High Power Supply 230 -3-60 Motor Rating 0.5 HP Total Unit Ampacity 24.3 Amps Power Input Requirement 0.66 KW Maximum Overcurrent Device Fuse Size 35 Amps Indoor Fan Motor Heat 2.3 MBH HACR Breaker Size 35 Amps Minimum Wire Size 10 AWG(60 C) PACKAGE UNIT CLEARANCES APPROXIMATE DIMENSIONS & WEIGHT" Front 32 in Back 36 in PACKAGE UNITS Bottom 0 in Top 72 in Left Side (filter access) 36 in Height 33 in Width 82 in Depth 45 in Right Side (outdoor 24 in Total Weight (incl factory options) 665 Lbs* INDOOR UNIT CLEARANCES SPLIT SYSTEMS in Side With RETURN AIR opening in Outdoor Unit:Height in Width in Depth Side With SUPPLY AIR opening in Outdoor Unit Total Weight Lbs Side With PIPING CONNECTIONS in Indoor Unit:Height in Width in Depth in Side Opposite PIPING CONN. in Intdoor Unit Total Weight 0 Lbs • Rigging Weight Engineer's Notes: NOTE: Check Local Codes • ORK ENGINEER'S REPORT Date 02/20/96 Page 13 Heeling end Air GAS/ELECTRIC ROOFTOP UNIT Order No Job Name Tigard School District Engineer - Architect Submitted By Alan Kolkemo QUANTITY: 1 Schedule No: RT -16 CR 3 Model No: D6CG036N07925EC COOLING PERFORMANCE HEATING PERFORMANCE Entering Air Temp. 50.0 F . • Total Capacity* 40.5 MBH Leaving Air Temp. 111.0 F Sensible Capacity 20.9 MBH Air Temp. Rise 61.0 F Efficiency (at ARI) 10.10SEER Electric Heat • Part Load Efficiency 0.0 IPLV Capacity N/A MBH Power Input N/A KW Power Input (w /o blower) 3.31 KW Elevation 300 Ft Leaving DB Temp 58.89 F Leaving WB Temp 56.43 F 4 Gas Heat Gas Fired Input 100 MBH Gas Fired Output 79 MBH N/A N/A AFUE 80.5 . % Outdoor DB Temp 90.0 F Heat Pump Entering DB Temp 75.0 F Capacity: 47F N/A MBH Entering WB Temp 67.0 F - 17F N/A MBH 'Gross Capacity COP: 47F N/A 17F N/A SUPPLY AIR BLOWER PERFORMANCE HSPF N/A Total Supply Air 1200 CFM 4 Indicates Heating Perfbnnance Type Outside Air 600 CFM ELECTRICAL DATA External Static Pressure 0.83 IWG Duct Location Bottom Single Package Blower Speed High Power Supply 230 -3-60 Motor Rating 0.5 HP Total Unit Ampacity 24.3 Amps Power Input Requirement 0.66 KW Maximum Overcurrent Device Fuse Size 35 Amps Indoor Fan Motor Heat 2.3 MBH HACR Breaker Size 35 Amps Minimum Wire Size 10 AWG(60 C) PACKAGE UNIT CLEARANCES APPROXIMATE DIMENSIONS & WEIGHT* Front 32 in Back 36 in PACKAGE UNITS Bottom 0 in • Top 72 in Left Side (filter access) 36 in Height 33 in Width 82 in Depth 45 in Right Side (outdoor 24 in Total Weight (ind factory options) 665 Lbs* • INDOOR UNIT CLEARANCES SPLIT SYSTEMS in Side With RETURN AIR opening in Outdoor Unit:Height in Width in Depth Side With SUPPLY AIR opening in Outdoor Unit Total Weight Lbs Side With PIPING CONNECTIONS in Indoor Unit:Height in Width in Depth in Side Opposite PIPING CONN. in Intdoor Unit Total Weight 0 Lbs • Rigging Weight Engineer's Notes: NOTE: Check Local Codes . ITYORIC ENGINEER'S REPORT Date 02/20/96 Page 14 Heakig end Air Condi:Ong GAS/ELECTRIC ROOFTOP UNIT Order No Job Name Tigard School District Engineer Architect Submitted By Alan Kolkemo QUANTITY: 1 Schedule No: RT -17 CR 4 Model No: D6CG036N07925EC COOLING PERFORMANCE HEATING PERFORMANCE Entering Air Temp. 50.0 F P. • Total Capacity' 40.5 MBH Leaving Air Temp. 111.0 F Sensible Capacity 20.9 MBH Air Temp. Rise 61.0 F Efficiency (at ARI) 10.10 SEER Electric Heat Part Load Efficiency 0.0 IPLV Capacity N/A MBH Power Input (w /o blower) 3.31 KW Power Input N/A KW Elevation 300 Ft Leaving DB Temp 58.89 F Leaving WB Temp 56.43 F 4 Gas Heat Gas Fired Input 100 MBH Gas Fired Output 79 MBH N/A N/A AFUE 80.5 % Outdoor DB Temp 90.0 F Heat Pump Entering DB Temp 75.0 F Capacity: 47F N/A MBH Entering WB Temp 67.0 F 17F N/A MBH 'Gross Capacity COP: 47F N/A 17F N/A SUPPLY AIR BLOWER PERFORMANCE HSPF N/A Total Supply Air 1200 CFM 4 IndIcates Heating Perfo,mance Type Outside Air 800 CFM ELECTRICAL DATA External Static Pressure 0.83 IWG Duct Location Bottom Single Package Blower Speed High Power Supply 230 -3-60 Motor Rating 0.5 HP Total Unit Ampacity 24.3 Amps Power Input Requirement 0.66 KW Maximum Overcurrent Device Fuse Size 35 Amps Indoor Fan Motor Heat 2.3 MBH HACR Breaker Size 35 Amps Minimum Wire Size 10 AWG(60 C) PACKAGE UNIT CLEARANCES APPROXIMATE DIMENSIONS & WEIGHT* Front 32 in Back 36 in PACKAGE UNITS Bottom 0 in Top 72 in Left Side (filter access) 36 in Height 33 in Width 82 in Depth 45 in Right Side (outdoor 24 in Total Weight (ind factory options) 665 Lbs* INDOOR UNIT CLEARANCES SPLIT SYSTEMS in Side Wdh RETURN AIR opening in Outdoor Unit: Height in Width in Depth Side With SUPPLY AIR opening in Outdoor Unit Total Weight Lbs Side With PIPING CONNECTIONS in Indoor Unit:Height in Width in Depth in Side Opposite PIPING CONN. in Intdoor Unit Total Weight 0 Lbs • Rigging Weight , - Engineer's Notes: NOTE: Check Local Codes .l . WORK ENGINEER'S REPORT Date 02/20/96 Page 15 a�Air GAS/ELECTRIC ROOFTOP UNIT Order No Job Name Tigard School District Engineer Architect Submitted By Alan Kolkemo QUANTITY: 1 Schedule No: RT -18 CR 5 Model No: D6CG036N07925EC COOLING PERFORMANCE HEATING PERFORMANCE • Entering Air Temp. 50.0 F . Total Capacity' 40.5 MBH Leaving Air Temp. 111.0 F Sensible Capacity 20.9 MBH Air Temp. Rise 61.0 F Efficiency (at ARI) 10.10SEER Electric Heat • Part Load Efficiency 0.0 IPLV Capacity N/A MBH Power Input N/A KW Power Input (w /o blower) 3.31 KW Elevation 300 Ft Leaving DB Temp 58.89 F Gas Heat Leaving WB Temp Gas Fired Input 100 MBH Gas Fired Output 79 MBH N/A N/A AFUE 80.5 % Outdoor DB Temp 90.0 F Heat Pump Entering DB Temp 75.0 F - Capacity: 47F N/A MBH Entering WB Temp 67.0 F 17F N/A MBH *Gross Capacity COP: 47F N/A 17F N/A SUPPLY AIR BLOWER PERFORMANCE HSPF N/A Total Supply Air 1200 CFM 4 Inolcates Heating Performance Type Outside Air 600 CFM ELECTRICAL DATA External Static Pressure 0.83 IWG Duct Location Bottom Single Package Blower Speed High Power Supply 230 -3-60 Motor Rating 0.5 HP Total Unit Ampacity 24.3 Amps Power Input Requirement 0.66 KW Maximum Overcurrent Device Fuse Size 35 Amps Indoor Fan Motor Heat 2.3 MBH HACR Breaker Size 35 Amps Minimum Wire Size 10 AWG(60 C) PACKAGE UNIT CLEARANCES APPROXIMATE DIMENSIONS & WEIGHT* Front 32 in Back 36 in PACKAGE UNITS Bottom 0 in Top 72 in Left Side (filter access) 36 in Height 33 in Width 82 in Depth 45 in Right Side (outdoor 24 in Total Weight (incl factory options) 665 Lbs* • INDOOR UNIT CLEARANCES SPLIT SYSTEMS in Side With RETURN AIR opening in Outdoor Unit:Height in Width in Depth Side With SUPPLY AIR opening in Outdoor Unit Total Weight Lbs Side With PIPING CONNECTIONS in Indoor Unit:Height in Width in Depth in Side Opposite PIPING CONN. in Intdoor Unit Total Weight 0 Lbs • Rigging Weight r Engineer's Notes: NOTE: Check Local Codes • ARK ENGINEER'S REPORT Date 02/20/96 Page 16 ■� emaroe GAS/ELECTRIC ROOFTOP UNIT Order No Job Name Tigard School District Engineer Architect Submitted By Alan Kolkemo QUANTITY: 1 Schedule No: RT -19 CR 15 Model No: D6CG036N07925EC COOLING PERFORMANCE HEATING PERFORMANCE Entering Air Temp. 50.0 F Total Capacity' 40.5 MBH Leaving Air Temp. 111.0 F Sensible Capacity 20.9 MBH Air Temp. Rise 61.0 F Efficiency (at ARI) 10.10SEER Electric Heat • Part Load Efficiency 0.0 IPLV Capacity N/A MBH Power Input N/A KW Power Input (w /o blower) 3.31 KW Elevation 300 Ft Leaving DB Temp 58.89 F Leaving WB Temp 58.43 F .4 Gas Heat Gas Fired Input 100 MBH Gas Fired Output 79 MBH N/A N/A _ AFUE 80.5 % Outdoor DB Temp 90.0 F Heat Pump Entering DB Temp 75.0 F Capacity: 47F N/A MBH Entering WB Temp 67.0 F 17F N/A MBH *Gross capacity COP: 47F N/A 17F N/A SUPPLY AIR BLOWER PERFORMANCE HSPF N/A Total Supply Air 1200 CFM 4 Indicates Heating Peifomrance Type Outside Air 600 CFM ELECTRICAL DATA External Static Pressure 0.83 IWG Duct Location Bottom Single Package Blower Speed High Power Supply 230 -3-60 Motor Rating 0.5 HP Total Unit Ampacity 24.3 Amps Power Input Requirement 0.66 KW Maximum Overcurrent Device Fuse Size 35 Amps Indoor Fan Motor Heat 2.3 MBH HACR Breaker Size 35 Amps Minimum Wire Size 10 AWG(60 C) PACKAGE UNIT CLEARANCES APPROXIMATE DIMENSIONS & WEIGHT" Front 32 in Back 36 in PACKAGE UNITS Bottom 0 in Top 72 in Left Side (filter access) 36 in Height 33 in Width 82 in Depth 45 in Right Side (outdoor 24 in Total Weight (inci factory options) 665 Lbs* INDOOR UNIT CLEARANCES SPLIT SYSTEMS in Side With RETURN AIR opening in Outdoor Unit: Height in Width in Depth Side Wdh SUPPLY AIR opening in Outdoor Unit Total Weight Lbs Side With PIPING CONNECTIONS in Indoor Unit:Height in Width in Depth in Side Opposite PIPING CONN. in Intdoor Unit Total Weight 0 Lbs • Rigging Weight Engineer's Notes: NOTE: Check Local Codes • WORK ENGINEER'S REPORT Date 02/20/96 Page 1 lieeting end Air Corcitiordeg GAS/ELECTRIC ROOFTOP UNIT Order No Job Name Tigard School District Engineer Architect Submitted By Alan Kolkemo QUANTITY: 1 Schedule No: RT -20 CR 16 Model No: D6CG036N07925EC COOLING PERFORMANCE HEATING PERFORMANCE - Entering Air Temp. 50.0 F • • Total Capacity' 40.5 MBH Leaving Air Temp. 111.0 F Sensible Capacity 20.9 MBH Air Temp. Rise 61.0 F Efficiency (at ARI) 10.10 SEER Electric Heat • Part Load Efficiency 0.0 IPLV Capacity N/A MBH Power Input (w /o blower) 3.31 KW Power Input N/A KW Elevation 300 Ft Leaving DB Temp 58.89 F Leaving WB Temp 56.43 F 4 Gas Heat Gas Fired Input 100 MBH Gas Fired Output 79 MBH N/A N/A AFUE 80.5 % Outdoor DB Temp 90.0 F Heat Pump Entering DB Temp 75.0 F Capacity: 47F N/A MBH Entering WB Temp 67.0 F 17F N/A MBH *Gross Capacity COP: 47F N/A N/A SUPPLY AIR BLOWER PERFORMANCE HSPF 17F N/A Total Supply Air 1200 CFM + Indicates Heating Pe,fonnance Type Outside Air 600 CFM ELECTRICAL DATA External Static Pressure 0.83 IWG Duct Location Bottom Single Package Blower Speed High Power Supply 230 -3-60 Motor Rating 0.5 HP Total Unit Ampacity 24.3 Amps Power Input Requirement 0.66 KW Maximum Overcurrent Device Fuse Size 35 Amps Indoor Fan Motor Heat 2.3 MBH HACR Breaker Size 35 Amps Minimum Wire Size 10 AWG(60 C) PACKAGE UNIT CLEARANCES APPROXIMATE DIMENSIONS & WEIGHT* Front 32 in Back 36 in PACKAGE UNITS Bottom 0 in Top 72 in Left Side (filter access) 36 in Height 33 in Width 82 in Depth 45 in Right Side (outdoor 24 in Total Weight (incl factory options) 665 Lbs* • INDOOR UNIT CLEARANCES SPLIT SYSTEMS in Side With RETURN AIR opening in Outdoor Unit:Height in Width in Depth • Side With SUPPLY AIR opening in Outdoor Unit Total Weight Lbs • Side With PIPING CONNECTIONS in Indoor Unit:Height in Width in Depth in Side Opposite PIPING CONN. in Intdoor Unit Total Weight 0 Lbs • Rigging Weight Engineer's Notes: NOTE: Check Local Codes . ORK' ENGINEER'S REPORT Date 02/20/96 Page 1 Hegira ardAir Cordtionitg GAS/ELECTRIC ROOFTOP UNIT Order No Job Name Tigard School District Engineer Architect Submitted By Alan Kolkemo QUANTITY: 1 Schedule No: RT -21 CR 17 Model No: D6CG036N07925EC COOLING PERFORMANCE HEATING PERFORMANCE • Entering Air Temp. 50.0 F • Total Capacity' 40.5 MBH Leaving Air Temp. 111.0 F Sensible Capacity 20.9 MBH Air Temp. Rise 61.0 F Efficiency (at ARI) 10.10SEER Electric Heat • Part Load Efficiency 0.0 IPLV Capacity N/A MBH Power Input (w /o blower) 3.31 K Power Input N/A KW Elevation 300 Ft Leaving DB Temp 58.89 F Leaving WB Temp 56.43 F 4 Gas Heat Gas Fired Input 100 MBH Gas Fired Output 79 MBH N/A N/A AFUE 80.5 % Outdoor DB Temp 90.0 F Heat Pump Entering DB Temp 75.0 F Capacity: 47F N/A MBH Entering WB Temp 67.0 F 17F N/A MBH *Gross Capacity COP: 47F N/A N/A SUPPLY AIR BLOWER PERFORMANCE - HSPF 17F N/A Total Supply Air 1200 CFM . Indreates Heating Performance Type Outside Air 600 CFM ELECTRICAL DATA External Static Pressure 0.83 IWG Duct Location Bottom Single Package Blower Speed High Power Supply 230 -3-60 Motor Rating 0.5 HP Total Unit Ampacity 24.3 Amps Power Input Requirement 0.66 KW Maximum Overcurrent Device Fuse Size 35 Amps - Indoor Fan Motor Heat 2.3 MBH HACR Breaker Size 35 Amps Minimum Wire Size 10 AWG(60 C) PACKAGE UNIT CLEARANCES APPROXIMATE DIMENSIONS & WEIGHT" Front 32 in Back 36 in PACKAGE UNITS Bottom 0 in Top 72 in Left Side (filter access) 36 in Height 33 in Width 82 in Depth 45 in Right Side (outdoor 24 in Total Weight (ind factory options) 665 Lbs* INDOOR UNIT CLEARANCES SPLIT SYSTEMS in Side With RETURN AIR opening in Outdoor Unit:Height in Width in Depth Side With SUPPLY AIR opening in Outdoor Unit Total Weight Lbs Side With PIPING CONNECTIONS in Indoor Unit:Height in Width in Depth in Side Opposite PIPING CONN. in Intdoor Unit Total Weight 0 Lbs • Rigging Weight Engineers Notes: NOTE: Check Local Codes ORK ENGINEER'S REPORT Date 02/20/98 Page 19 Hazing erdAk GAS/ELECTRIC ROOFTOP UNIT Order No Job Name Tigard School District Engineer . Architect Submitted By Alan Kolkemo QUANTITY: 1 Schedule No: RT -22 CR 18 Model No: D6CG036N07925EC COOLING PERFORMANCE HEATING PERFORMANCE Entering Air Temp. 50.0 F Total Capacity' 40.5 MBH Leaving Air Temp. 111.0 F Sensible Capacity 20.9 MBH Air Temp. Rise 61.0 F • Efficiency (at ARI) 10.10 SEER Electric Heat Part Load Efficiency 0.0 IPLV Capacity N/A MBH • Power Input N/A KW Power Input (w /o blower) 3.31 KW Elevation 300 Ft Leaving DB Temp 58.89 F Leaving WB Temp 56.43 F 4 Gas Heat Gas Fired Input 100 MBH Gas Fired Output 79 MBH N/A N/A AFUE 80.5 % Outdoor DB Temp 90.0 F Heat Pump Entering DB Temp 75.0 F Capacity: 47F N/A MBH Entering WB Temp 67.0 F 17F N/A MBH 'Gross Capacity COP: 47F N/A 17F N/A SUPPLY AIR BLOWER PERFORMANCE HSPF N/A Total Supply Air 1200 CFM 4 Indicates Healing Performance Type Outside Air 800 CFM ELECTRICAL DATA External Static Pressure 0.83 IWG Duct Location Bottom Single Package Blower Speed High Power Supply 230 -3-60 Motor Rating 0.5 HP Total Unit Ampacity 24.3 Amps Power Input Requirement 0.66 KW Maximum Overcurrent Device Fuse Size 35 Amps Indoor Fan Motor Heat 2.3 MBH HACR Breaker Size 35 Amps Minimum Wire Size 10 AWG(60 C) PACKAGE UNIT CLEARANCES APPROXIMATE DIMENSIONS & WEIGHT* Front 32 in Back 36 in PACKAGE UNITS Bottom 0 in Top 72 in Left Side (filter access) 36 in Height 33 in Width 82 in Depth 45 in Right Side (outdoor 24 in Total Weight find factory options) 665 Lbs* INDOOR UNIT CLEARANCES SPLIT SYSTEMS In Side With RETURN AIR opening in Outdoor Unit:Height in Width in Depth Side With SUPPLY AIR opening in Outdoor Unit Total Weight Lbs Side With PIPING CONNECTIONS in Indoor Unit:Height in Width in Depth in Side Opposite PIPING CONN. in lntdoor Unit Total Weight 0 Lbs • Rigging Weight - Engineer's Notes: • NOTE: Check Local Codes