Specifications FPS9.o10 `750 I S(%) c a 10/20/2010 FIRE ALARM SYSTEM o ctDO _ �.� SUBMITTALS oc i 2 %2 ono C N�DVIS 0 B��D P T SMA R ., IL. STORE #0387 7501 S.W. DARTMOUTH TIGARD, OR 97223 r I r . r Equipment & Submittal Furnished by: . 't. F.E.MORAN,INC. I Alarm and Monitoring Services 33341 KELLY RD FRASER, MI 48026 Phone: 586- 228 -5788 Fax: 586- 228 -5758 Fire Alarm Systems I FPD -7024 Fire Alarm Control Panels BOSCH Invented for life FPD -7024 Fire Alarm Control Panels • Four initiating zones (expandable to eight); up to 20 two -wire smoke detectors per zone • Built -in DACT • Two notification appliance circuits (NACs) on board with a shared internal regulated 24 VFWR, 4 A NAC power supply • Easily converts to addressable with the addition of a D7039 Multiplex Expansion Module • Programmable through front panel interface, remote FMR -7033 Liquid - crystal Display (LCD) Keypads, remote programming software (RPS), or DX4010V2 or DX4020 The FPD -7024 Fire Alarm Control Panels (FACPs) can be Functions • used in commercial and public building applications such as schools, universities, manufacturing plants, and health Notification Appliance Circuits (NACs) care facilities. They are listed by UL for central station, local, Two Class A, Style Z or Class B, Style Y NACs provide up to auxiliary, and remote station systems. 4 A of regulated 24 VFWR power to operate horns, strobes, bells, and other notification appliances. Each NAC can be The FPD-7024 FACPs support four on board initiating zones programmed to provide Temporal Code 3, California March, that can be expanded to eight using the FPC -7034. Each steady, pulsed, and synchronized output for either initiating zone supports two -wire and four -wire detectors Wheelock or System Sensor notification appliances. configurable as Class A , Style D or Class B, Style B loops. User Interface Each zone can support up to 20 two -wire detectors, or any number of four -wire detectors depending on available A viewing port in the locked control panel enclosure door power. Each FACP has a built in digital fire alarm shows the system status light- emitting diodes (LEDs) and communicator transmitter ( t-in di liquid-crystal display (LCD) while maintaining system keypad security. Unlocking the enclosure door provides Enhance the FPD -7024 conventional system features by access to the system controls for silencing off - normal adding a D7039 Multiplex Expansion Module. Adding a conditions, zone bypassing, detector resetting, testing, D7039 Multiplex Expansion Module to the FPD-7024 turns other fire functions, and programming. These functions are the conventional FACP into an addressable FACP. The also available on all FMR -7033 LCD Keypads connected to D7039 adds up to 247 addressable points to the base the system. system and adds an additional 400 events to the history buffer for a total of 499 events. The D7039 also increases Organized Event Display the number of programmable relay outputs from 19 to 59 Sorts alarm, trouble, and supervisory events into categories and expands system users to 100, and allows scrolling through specific events. History Buffer The system stores events in a 99 -event history buffer. Note The number of events that can be stored in the history buffer increases to 499 with the www.boschsecurity.com • 2 I FPD -7024 Fire Alarm Control Panels . . • addition of a D7039 Multiplex Expansion Category Product ID Product Description Module. D7030X-S8 Eight -point LED annunciator Central Station Reporting (eight yellow) The FPD -7024 FACPs send reports to two telephone D7032 Eight -point LED annunciator ex- numbers (or IP addresses with a DX4020 Network Interface pander Module installed) with full single, double, and backup (eight red) reporting. They communicate in BFSK, SIA, Contact ID, FMR-7033 LCD fire system keypad Modem 11la and 4/2 and 3/1 Tone Bursts. FMR-7036 LCD annunciator Dirty Smoke Detector Monitoring Modules D132B Smoke detector reversing relay module All on -board zones and FPC -7034 zones are continuously D184A Local energy kit monitored for smoke detectors signaling a dirty condition D185 Reversing polarity module using the Bosch Chamber Check feature and CleanMe protocol. If a detector's smoke chamber is dirty, the D275 EOL power supervision module detector sends a CleanMe signal on the two -wire loop or a FPC-7034 Four point expander dirty detector signal on the addressable loop. The control D7039 Multiplex expansion module panel annunciates that there is a dirty detector on the loop Option Bus Devi- D7035 Octal relay module or the address. The Chamber Check feature signals a dirty ces smoke chamber using the LED on the detector head. D7035B Octal relay module in box Accessories DX4010V2 USB /serial interface module The FPD -7024 enclosure has space for additional accessory DX4020 Network interface module modules and two D1218 (18 Ah) batteries or two D126 NAC Devices Refer to FPD-7024 Device Compatibility List Techno- (7 Ah) batteries. gram (P /N: F01U010791) The following additional products are compatible with the FPD -7024 Addressable FACPs: Certifications and Approvals .... ....... .. _ .. ._..... _. Category Product ID Product Description Region Certification Detector Heads D7050 Addressable Photoelectric Smoke USA UL UL864, 9th edition and Bases Detector Head FM D7050TH Addressable Photoelectric Smoke and Heat Detector Head CSFM 7165 - 1615:227 D7050 -B6 Detector Base • FCC ESVAL04B7024 Modules D7042 Multiplex eight -input remote mod - FDNY- #6024 ule CoA D7042B Multiplex eight -input remote mod- ule in box D7044 Multiplex single-input module Installation /Configuration Notes D7044M Mini multiplex single -input module Compatible Products D7048 Multiplex octal driver • The following products are compatible with the FPD-7024 D7048B Multiplex octal driver in box FACP: D7052 Multiplex dual -input module D7053 Multiplex input- output module Category Product ID Product Description Pull Stations FMM -7045 Single- action manual station Batteries and D126 12 V, 7 Ah battery FMM- 7045 -D Double-action manual station Power Supplies D1218 12 V,18 Ah battery D7038 Remote NAC power supply Detectors For two-wire detector compatibility, refer to FPD -7024 Smoke Detector Compatibility List Technogram (P1 N: FO1U010790) Keypads and D7030X Eight -point LED annunciator Annunciators (eight red) D7030X -S2 Eight -point LED annunciator (two yellow, six red) • • FPD -7024 Fire Alarm Control Panels 3 Parts Included Trademarks Trademark names are used throughout this document. In aunt. Component most cases, these designations are claimed as trademarks 1 FPD -7024 board in a static - resistant bag or registered trademarks in one or more countries by their • 1 Enclosure (P /N: 30897) respective owners. Rather than placing a trademark symbol 1 Lock set with two #1358 (0102) keys (P /N: FO1U009775) in every occurrence of a trademark name, Bosch Security 1 Transformer (P/N: F010008702) Systems, Inc. uses the names only in an editorial fashion and to the benefit of the trademark owner with no intention 6 2.21 kO end -of -line (EOL) resistors (P /N: 25899 or 4998113202) of infringing the trademark. 1 Hardware pack Chamber Check is a registered trademark of Bosch Security Systems, Inc. 1 Literature pack in the United States. Note For the FPD-7024 to be addressable, a D7039 CleanMe is a registered trademark of GE Interlogix in the United States and/ or other countries. Multiplex Expansion Module must be installed. Wheelock is a trademark of Cooper Wheelock, Inc. The D7039 is purchased separately. System Sensor is a registered trademark of System Sensor, a brand of Hon- eywell International, Inc. in the United States and /or other countries. Technical Specifications Electrical Ordering Information Current (alarm): 380 mA FPD -7024 FACP FPD -7024 Four detector zones (expandable to eight); up Current (standby): 200 mA _ to 20 two wire smoke detectors per zone Power (primary): 120 VAC, 1.2 A maximum, 60 Hz or FPD-7024 -LC FACP without Enclosure and FPD - 7024 -LC 240 VAC, 0.75 A maximum, 50 Hz Transformer Environmental Four detector zones (expandable to eight); up to 20 two wire smoke detectors per zone Environment: Indoor, dry FPD - 7024 -LT FACP without Transformer FPD-7024-LT Relative Humidity: _ Up to 95%, non condensing Four detector zones (expandable to eight); up Temperature (operating): +32 °F to +120°F (0 °C to +49 °C) to 20 two wire smoke detectors per zone. Available only in Latin America. Mechanical Properties Color: Red Dimensions (HxWxD): 20.8 in. x 15 in. x 4.3 in. (52.8 cm x 38.1 cm x 10.9 cm) _ Material: Cold- rolled steel Base: 18 gauge (1.2 mm) Cover: 19 gauge (1.1 mm) Indicating Device Circuits (IDC) Current: _ 44 mA maximum per loop Line resistance: 150 0 Voltage: 24 VDC nominal Outputs NAC: _ 24 VDC nominal, 4 A maximum On -board Relays: Three Form C contacts rated at 5 A, 28 VDC Off -board Relays: Up to two D7035 Octal Relay Modules with each pro- viding eight Form C relay outputs; contacts rated at 5 A, 28 VDC In an addressable system, up to 20 D7053 Multiplex Input - Output Modules are allowed per bus for a total of 40 www.boschsecu rity.coin • Sealed Lead -Acid Batteries , 1' 1 M y II 2V11 ��A3>W i 181 77 , co Nona • III.6I. 1l.CA.t•••b. 0.■1.0 L..d Acid 9•H.ry k. -c _ '1 . .. - ' 18 w .n �� �o u, C n.o . , ' , o 1 r — � •- UL recognized File # MH45246 • Specifications Voltage characteristic (100% Discharged) Nominal Voltage 12V w„E CAW VUME 120 a) Um Wm.) Rated Capacity 18Ah CHARGED VOLUME 100 _ 2.30 _ _ Total Height 6.57 inches (167mm) CARGO) VOLTAGE Height 6.57 inches (167mm) 80 - °I0 2.15 - Dimensions Length 7.12 inches (181mm) 60 _ o08. 200 •\ Width 3.03 inches (77mm) 40 - "6- Approximate Weight 11.00 lbs. (5.0kg) 084_ 1 _ 20 • Characteristics - 002_ CHARGING CURRENT 0 - 0- 0 5 10 15 20 25 30 35 40 20h rate 18Ah . Chargeing T (h) 10h rate 18Ah Capacity 5h rate 14.4Ah 77°F(25 °C) Float service life VS temperature lh rate 12.2Ah 20 15 min rate 8.3Ah to Full Charged Battery Approx. 5 Internal Resistance ��- a,... -.r, y .. 77 ° C) 16m D tu 2.27-2.30V/�l Capacity 104 ° F(40 ° C) 102% w Affected by 77 ° C) 100% - 1 03 Temperature 32 ° F(0 ° C) 85% �^ 0.5 (20h rate) 5 ° F( -15 ° C) 65% Self - Discharge 3 month storage 90% 0.1 68 ° F(20 ° C) 6 month storage 80% 10 20 30 40 50 60 70 (Capacity after) 12 month storage 60% Ambient temperature (i E) Max. Discharge 255A(5s) Current 77 ° F(25 ° C) Terminal T2 14.5-14.9V(-24m V / Charge Cycle max. current: 5.4 A (Constant Voltage,25 ° C) Float 13.6-- 13.8V(- 18mV/ - 1 of 2 Sealed Lead -Acid Batteries U7112118 (112V 3AN1 Constant Current Discharge Characteristics (A,25 ° C) , F.V /TIME 5min 10min 15min 30min 60min 3h 5h 10h 20h 9.60V 70.0 45.0 36.0 20.0 12.0 4.47 3.05 1.83 0.91 10.2V 66.5 42.8 34.6 19.2 11.5 4.40 3.00 1.81 0.91 10.8V 62.5 40.2 32.8 18.2 10.9 4.31 2.94 1.80 0.90 Constant Wattage Discharge Characteristics (Watt,25 ° C) • F.V /TIME 5min 10min 15min 30min 60min 3h 5h 1Oh 20h 9.60V 781 508 410 229 139 53.1 36.4 20.7 11.0 10.2V 742 482 394 220 133 52.3 35.8 20.5 10.9 10.8V 698 453 374 209 127 . 51.2 35.1 20.5 10.8 Cycle service life Self Discharge Characteristic • 110 120 \ 100 ' 100 G \ \ u \ ° � 8D v 90 1 tV7 60 Dlcc02. * pso 1001 0lsclar * , 501 as :no�q aevtn 70Z 0 0� ,"1`', 00 40 60 „ "-„ ` i. 20 50 ii"-11∎ 0 0.00104•rl 30 20 200 400 600 800 1000 1200 40 1 I I I I Life (cycle) 0 1 2 3 4 5 6 7 8 9 10 11 121314 15 16 17 18 19 20 • Storage time (months) Charging voltage V'S temperature Open circuit voltage and remaining capacity 162 -8.1 -27 (At 201 EC) 2 15 -78 -26 . 230 _ - U- OD 150 - 73 - 2.5 \_ > 220 - B cYc( jS > 144 _ 72 _2.4 a 441 2.10 °o /' - • 88, , 138 _ 69 - 2.7 S �ndb u$ ' 200 ' - e.- 132 -66 -22 190 - , 4+ : O _ 12.6 -63 - at DO 1.80 - -10 0 10 20 30 40 50 60 0 10 20 30 40 50 60 70 80 90 100 Remained capacity(%) Ambient temperature ( G) 2 of 2 Fire Alarm Systems I D7036 Fire Annunciator Keypad BOSCH Invented for life D7036 Fire Annunciator Keypad • Compatible with D7024 Series Fire Alarm Control Panels : ® • Two -line, 16- character LCD display ► On -board LEDs indicate Silenced, Trouble, Alarm, and FIRE SYSTEM Power ANNUNCIATO • Silence and Reset buttons • Built -in keyswitch • Attractive, low - profile enclosure • UL Listed The D7036 is a four -wire LCD annunciator keypad used with Installation /Configuration Notes the D7024 Series Fire Alarm Control Panels (FACP) to Compatible Products establish the location of a fire alarm. The two -line, 16- character display is capable of showing all messages Category Product ID Product Description normally displayed on the control panel. All alarm and Control D7024 Four -zone FACP status messages are included. Four on -board LEDs provide Panels D7024LC Four -zone FACP without enclosure • easy reading of the annunciators status from a distance. D7024-EXP Four-zone FACP for export There are Silence and Reset buttons for controlling D7024-EXPLC Four-zone FACP for export without en annunciator and control panel operation. A built -in closure keyswitch offers extra security by locking out the annunciator to prevent unwanted sounder silencing or Mounting control panel resetting. The D7036 can be surface mounted on a standard three - gang box, or with the mounting backplate provided. Wiring Guidelines Certifications and Approvals For the D7024 FACPs, the maximum allowed DC current draw from the auxiliary power is 500 mA for keypads. The Region Certification maximum length of wire (all branches added together) that can be connected to the option bus terminals is 4000 ft USA UL UOXX: Control Unit Accessories, System (1220 m). (UL864, 9th edition) FM CSFM 7120 -1615: 185 July 2008 NYC -MEA 12 -92 -E, Vol. 14 r www.boschsecurity.com 2 I D7036 Fire Annunciator Keypad - 9 The maximum length between any one device and the control panel terminals depends on the current draw on the branch that the device is on. The current draw on a particular branch can be found by adding together the . . individual current draws of each device connected to the branch. Note Refer to the D7024 Operation and Installation Guide (P /N: 31499) for complete wire length calculations. Number of Keypads Up to four keypads can be used per system. Up to three keypads can be used on any single 1000 ft (305 m) run of 18 AWG (1.2 mm) wire. Technical Specifications Mechanical Properties Base Dimensions (H x W): 4.6 in. x 8.2 in. (11.7 cm x 20.8 cm) Cover Dimensions (H x W): 4.3 in. x 8.1 in. (10.9 cm x 20.6 cm) Power Requirements Current (Alarm): 100 mA Current (Standby): 80 mA nominal Voltage (Operating): 12 VDC nominal • • Ordering Information D7036 Fire Annunciator Keypad D7036 Four -wire LCD annunciator keypad used with the D7024 Series Fire Alarm Control Panels to establish the location of a fire alarm Accessories KEY-ANN Replacement Key KEY -ANN This is a spare or replacement key for the D7036 lock. Americus Europe, Middle East, Africa: Asia.Paciflcs Represented by Bosch Security Systems. Inc. Bosch Security Systems B.V. Robert Bosch (SEA) Pte Ltd. Security Systems 130 Pennton Parkway P O. Box 90002 11 Blshan Street 21 Fairport, New York, 14450, USA 5600 JB Eindhoven, The Netherlands Singapore 573943 Phone •1 800 289 0096 Phone: • 31 40 2577 284 Phone •65 6258 5511 Fax +1 585 223 9180 Fax .31 40 2577 330 Fax- •65 6571 2698 security sales ®us Bosch corn emea.secuntysystems ® bosch com apr secuntysystemsebosch.com www.boschsecurity us www boschsecurity corn www boschsecurlty.com O Bosch Security Systems Inc 20101 Data subject to change without notice T1303193611 I Cur on-US, V7, 4 Jul 2010 FMR -7036 I Fire Annunciator Keypad I 5.0 Setting the FMR -7036 Address Figure 3: Mounting Hole Locations 5.0 Setting the FMR -7036 Address 1 1 0 - Each keypad must have its address set 0 with its address pins. The keypads must also be programmed at the control panel. 0 5: FMR -7036 Address Jumper Settings Y 3 0 Address 1 Address 2 Address 3 + • 1193••••••1 1•• ®••••� tc ojo c:1=1 1 213 415 617 8 1 213 415 617 8 1 213 415 617 8 Back of FMR -7036 Keypad Address 4 Address 5 Address 6 1 2 3 415 617 8 1 213 415 617 6 1 213 415 617 8 Address 7 Address 8 Address 9 1 - Holding tabs for reference guides [M=M1=1 MarE1221 11 •••• 1 213 415 617 8 1 213 415 617 8 1 213 415 617 8 2 - Release tab Address 10 Address 11 Address 12 3 - Mounting Hole m F-mmI =M=E31 OEM J 1 213 415 617 8 1 213 415 617 8 1 213 415 617 8 4 - Wire Entrance Address 13 Address 14 Do not use •• address 15 1 2I3 4I 6I7 8 1 213 415 617 8 Do not secure the base at t point Select the keypad address (1-14). Place the shorting jumpers over the address pins as shown in Figure 5. Figure 4: Inside View of FMR -7036 Keypad Each option bus device must have its own O 0 © address, and each address can only support one device. 7 ........,.....,_.- 1 ®® 0 6.0 Wiring the FMR -7036 41110 : - . Opp. I • O 1 II /A Be sure all wiring is un-powered before © o O JI routing. Keypad wiring cannot be run with I p smoke detector wiring, NAC wiring or MUX Q • • ' �■, ° © loop wiring. Rp.------.N For the FPD -7024 FACP, the maximum allowed DC current draw from the auxiliary power is 500 mA for CEV Idd, keypads. The maximum length of wire (all branches ow added together) that can be connected to the option Connector Cable Orientation bus terminals is 4000 ft (1,219 m). The maximum length between any one device and - -____---"/ the panel terminals depends on the current drawn 1 - Wire Entrance on the branch that the device is on. The current 2 - Internal Sounder draw on a particular branch can be found by adding 3 Mounting Hole together the individual current draws of each device 4 - Address jumper pins connected to the branch. 5 Control Keys Refer to the FPD -7024 Installation Guide 6 Reset switch (P/N: F01 U008458) for detailed wire length 7 - 2 -line 16- character display calculations. 8 - Lock 4 Bosch Security Systems, Inc. I 9/08 I F01 U010584 -01 Fire Alarm Systems I D7039 Multiplex Expansion Module BOSCH Invented for life D7039 Multiplex Expansion Module • • Has two Class B (Style 4) multiplex buses (supports addresses 9 to 255) i „,, - _ _, : ••p • Provides one Class A (Style 6) multiplex bus (supports - --ti , a addresses 9 to 128) _ . l ° r — u • Expands number of user codes to 100 PINs _ • Increases event history buffer to 499 events i r 2 • Compatible with RPS • Easy to install •— — : i • • The D7039 Multiplex Expansion Module is designed to • �•. P P g Installation /Configuration Notes enhance the conventional features of the D7024 or Compatible Products FPD -7024 Fire Alarm Control Panel (FACP). The D7039 connects directly to the FACP and results in a total of up to The following products are compatible with the D7039 255 addressable points. The D7039 also increases the Multiplex Expansion Module: number of relay outputs (to 58 on the D7042 control panels Category Product ID Product Description and 59 on FPD -7024 control panels), adds an additional 400 Control D7024 Addressable and conventional FACP events to the history buffer for a total of 499 non - volatile Panels D7024 -EXP Addressable and conventional FACPforex- events and also allows for up to 100 system users (an port addition of 84 PINs from the base system). FPD -7024 Addressable and Conventional FACP The D7039 can be programmed remotely from a PC using Mounting Considerations the RPS Remote Programming Software. The D7039 mounts onto the control panel board inside of Note The D7024 Is not listed under UL864, 9th the control panel's enclosure using connector pins. The edition. D7039 Input- Output board mounts to the inside wall of the enclosure for field wiring. Wiring Considerations Certifications and Approvals Refer to control panel's installation guide for additional wiring requirements. Region Certification USA UL UL864, 9th edition FM CSFM 7165-1615: 147 7165-1615:227 NYC -MEA 12-92-E, Vol. 14 www.boschsecurity.com 2,1 D7039 Multiplex Expansion Module , , , Maximum Impedance: 50 Oat +20 °C ( +68°F) nominal Distance (approximate) Size 1170 m .1.0 mm 1810m 1.5 mm 3800 ft - -- 18 AWG - - -' -- - -_ -_ - - - -_ 5950 ft 16 AWG Note Do not use shielded cable. Twisted pair is acceptable but not recommended. Note If used in fire applications, a minimum of 18 AWG wire is required. Parts Included Quant. Component 1 D7039 board 1 D7039 Input-Output board 3 Standoffs for input - output board 4 Standoffs for D7039 board 1 Literature pack • • 1 Technical Specifications Environmental Considerations Environment: . Indoor, dry Power Requirements Current (load): 100 mA maximum each bus Current (alarm and standby): 150 mA maximum Resistance (bus wiring): 50 fl maximum Voltage (bus): 12 VDC nominal • Voltage (input) 24 VDC nominal i Ordering Information • D7039 Multiplex Expansion Module D7039 Enhancse the conventional features of the D7024 or FPD -7024 Fire Alarm Control Panel (FACP) providing a total of up to 255 address- able points Americas, Europe, Middle East, Africa, Asia-Pacific, B ed by Bosch Security Systems. Inc Bosch Security Systems B.V Robert Bosch (SEA) Pte Ltd. Security Systems 130 Pannton Parkway P.O Box 80002 11 Bishan Street 21 Fairport, New York. 14450, USA 5600 JB Eindhoven, The Netherlands Singapore 573943 Phone +1 800 289 0096 Phone: • 31 40 2577 284 Phone: +65 6258 5511 Fax +1 585 223 9180 Fax +31 40 2577 330 Fax +65 6571 2698 security saleseus.bosch corn emea.securitysystems®bosch corn apr.secuntysystemsebosch coin www.boschsecurity us www boschsecurlty.com www.boschsecurity.com I. O Bosch Security Systems Inc. 2010 I Data subject to change without notice Y2593898763 I Cur. ends, V6, 4 Jul 2010 • 0 A l t r o n i x ® AL602ULADA, AL802ULADA, AL 1002ULADA NAC Power Extenders Rev. AL60 2/802/1002ULADA- A051 Overview ' The AL602ULADA, AL802ULADA and AL1002 are extremely cost � 4 6 effective voltage regulated remote NAC Power Extenders. They may be connected ;: to any 12 or 24 volt Fire Alarm Control Panel (FACP). Primary applications l am* ; , . , include Notification Appliance Circuit (NAC) expansion (supports ADA requirements) and will provide auxiliary power to support system accessories. fa 1 I AL602ULADA AL802ULADA AL1002ULADA =" • 24VDC or 12VDC • 24VDC or 12VDC • 24VDC rated ?." rated @ 6.5 amp max. rated @ 8 amp max. @ 10 amp max. • Two (2) Class A or • Two (2) Class A or • Two (2) Class A or four (4) Class B outputs. four (4) Class B outputs. four (4) Class B outputs. . AL602ULADAJ AL802ULADAJ AL1002ULADAJ • Larger enclosure. • Larger enclosure. • Larger enclosure. Specifications • Two (2) Class A or two (2) Class B FACP inputs. • Temporal Code 3 Mode. • Two (2) NC dry contact trigger inputs • Steady Mode. (AL802ULADA and AL1002ULADA only) • Input to Output Follower Mode (maintains • Two (2) Class A or four (4) Class B synchronization of notification appliance circuits). indicating circuits. • March Time. • Two (2) Class B outputs may be paralleled for more • Compatible with 24VDC or 12VDC fire panels. power on an indicating circuit. • Common trouble inputs and outputs. • One (1) Aux. Power Output @ 1 amp supply current • Ground fault detection. (w/battery back up). • Input 115VAC. • Signal Circuit Trouble Memory - facilitates quickly • AC fail supervision (form "C" contacts). locating intermittent system trouble and eliminates • Low battery supervision (form "C" contacts). costly and unnecessary service calls. LED's indicate a • Battery presence supervision (form "C" contacts). prior fault (short, open, ground) has occurred on one • Power supply, logic board, red enclosure, cam lock, or more signaling circuit outputs. transformer & battery leads. • 2 -wire Horn/Strobe Sync mode allows audible • Enclosure: notification appliances (Horns) to be silenced while - Combination knockouts re 1/2" and 3/4" visual notification appliances (Strobes) continue - Accommodates up to two (2) to operate. 12VDC /12AH batteries. • Horn/Strobe sync protocols include: Gentex ®, System Sensor®, Faraday, Amseco. Agency Approvals 0 UL Listed Control Units and Accessories !� y•v for Fire Alarm Systems (UL 864), () California State Fire Marshal Approved. UL Listed Standard for Safety for Fire ii„ Protective Signaling Systems (UL 1481). M EA NYC Department of Buildings Approved. ® Factory Mutual Approved. Approved APPROVED Enclosure Dimensions AL602ULADA, AL802ULADA and AL1002ULADA: 15.5 "H x 12 "W x 4.5"D IF LJ IJ • 0 0000 R fl 0000 (� 4? 000000 r 0 0000 ell 000000 0 0000 000000 0 °0 00000000 0 0000 .e 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 000000 000000 0 .00c, 00000 0000 00000 D 1 G1 G1 lairmiamitira AL602ULADAJ, AL802ULADAJ and AL1002ULADAJ: 18 "H x 14.5 "W x 4.625 "D 11]0• — OS0��7]0 '! LJ 1.00 I SO v-i SF •J I e!°• o o e :0 °o °o °o °00 0 0 00 0 0 0 0 0 0 0 0 0 ° e ° 000000 00 °000 0 0 0 0 o e o u ° o o ° o ° o ° 6 � 0 ° 0 ° 0 0 0 0 0 0 a 00000 1100• I ,000• 11100. `J LJ St- 1.00 „01 1430 • lJ I J I —7 7$ 430• —�SD�z ls•—y : 0111111 Corp. - 1411 9011 >,rcc,, n. \Y 112211 • 718- %7 -8I8I • 88N-258-760 • :,I,rnni cnm - ... Sealed Lead -Acid Batteries U T)1 27 (.12 V7A , • - f �Af - �' • I • I ED,. . _____ _... I I : Honapillabl. R•ch•p••bl. S•l.d L•.d Acid B.tt•ry \ - a.•ct UL recognized File # MH45246 • Specifications Nominal Voltage 12V MI 151 Rated Capacity 7Ah Total Height 3.98 inches (101mm) Cc staltVbltalge Charaaeris is (100% Dialoged) Height 3.74 inches (95mm) Dimensions MIST °� Length 5.94 inches (151mm) 120 ar °E" CHARGED VELURE Width 2.56 inches (65mm) loo _ 230 _ CHARGED VELTAGE Approximate Weight 4.62 lbs. (2.10kg) 8, - z15 aD_ - GO - OM_ Z00 • Characteristics oa - .0 _ - 20h rate (035A) 7Ah co - 402_ 10h rate (0.7A) 7Ah 0 _ 0_ °uRG°'G CURRENT Capacity 0 5 10 is 60 25 30 35 40 . 77°F(25°C) Sh rate (1.12A) 5.6Ah Ompling Tyre (h) lh rate (4.76A) 4.76Ah 15 min rate (13 2A) 3.3Ah Float service life VS t m attne Full Charged Battery Approx. 20 Internal Resistance 77 ° F(25 ° C) 25m 0 10 Capacity 104 ° C) 102% 5 Affected by 77 100% T 227 130V /cal Temperature 32 ° F(0 ° C) 85% w 1 (20h rate) 5 -15 65% c g, 0.5 Self-Discharge 3 month storage 90% 68 ° F(20 ° C) 6 month storage 80% (Capacity after) 12 month storage 60% 01 l0 20 30 40 50 60 70 Max. Discharge Ambiern tempaatxe(i C) 105A(5s) Current 77 ° F(25 ° C) Terminal T1 14.5 --14.9 V (-24m V/ Charge Cycle max. current: 2.1 A (Constant Voltage,25 ° C) Float 13.6- 13.8V(- 18mV/ r I of 2 Sealed Lead -Acid Batteries UT11270 (U2V7A8i ) 2) I, Cycle service life Self Discharge Characteristic uo - 120 100 _ too ` \ \ ` \\ \ 90 1 ,� 5 80 \ 1 C 60 OscnOrq depth 1002 06c02 0. oven 302 at:ne. 9. Mpan Sox Q 0o "„`'„ U 60 „"- „1 S .0 ` 20 50 IIH i ,� o To 30'c<86•r) 20•C 468•I) 200 .m 6m 000 Imo 1200 40 I I I I Life (cycle) 0 1 2 3 4 5 6 7 8 9 10 11 121314 15 16 17 181920 Storage tine (months) Charging voltage V'S temperature Open circuit voltage and remaining capacity 162 -G1 - (At 201 6) S 116 - 28 W 230 OD LSD -)] -25 ` I 22^ ''% i a cYck jS m > I.._ -2. e - ° 210 - e0 > - ' - . 13.8 - 2.3 sarldb - r 2m� ' ° 132 -66 -22 - 1.90 - r o _ 12.6 -6.3 -21 I80 - -10 0 10 20 30 40 50 60 0 10 20 30 40 50 60 70 80 90 too M Remained capacity( %) Ambient temperature (1 C) 0 . Constant Current Discharge Characteristics (A,25 ° C) F.V /TIME 5min 10min 15min 30min 60min 3h 5h 10h 20h 9.60V 27.0 18.0 14.0 8.40 4.70 1.73 1.15 0.71 0.37 10.2V 25.7 17.1 13.4 8.06 4.55 1.70 1.13 0.70 0.36 10.8V 24.2 16.1 12.7 7.66 4.35 1.65 1.10 0.68 0.35 Constant Wattage Discharge Characteristics (Watt,25 F.V /T1ME 5min 10min 15min 30min 60min 3h 5h 10h 20h 9.60V 301 203 160 94.2 54.4 20.6 13.8 8.52 4.43 10.2V 287 191 153 90.4 52.7 20.2 13.6 8.40 4.33 10.8V 270 180 145 86.0 50.4 19.6 13.2 8.17 4.21 2 of 2 Fire Alarm Systems I D7050 Series Addressable Photoelectric Smoke and Smoke. Heat Detector Heads • B OSCH Invented for life D7050 Series Addressable Photoelectric Smoke and Smoke Heat Detector Heads ► Connects to the multiplex bus of the FPD -7024 or D7024 Addressable FACP and the DS7400X1 Control Panel 7 • Superior dust immunity ' • Exclusive Chamber Check self- diagnostics {! • • Automatic sensitivity test features • j, • Easy disassembly for cleaning r l • The D7050 Photoelectric Smoke and Smoke Heat Detector Functions - Heads are UL Listed, open -area photoelectric smoke Detector Head and Base System detectors designed for use with commercial fire protective signaling systems and household fire warning systems (see The D7050 Photoelectric Smoke and Smoke Heat Detector NFPA 72, the National Fire Alarm Code). They are Heads are part of a compound system of detector head and compatible with the FPD -7024 or D7024 Addressable Fire base. The detector base installs over a back box and • Alarm Control Panels (FACPs) and the DS7400Xi Control contains all the wiring. The detector head attaches to the Panel. base by aligning the head with the base and turning it clockwise. No tools are required for installation other than They detect large smoke particles by scattering light from a the hex key used to tighten the tamper screw. Each detector pulsed infrared source operating with a gated, high- speed, head requires a D7050 -B6 detector base. photodiode infrared sensor. The symmetry of the optical Chamber Check Self- diagnostics chamber allows 360° uniform smoke entry, but minimizes external light entry. The detector meets NFPA guidelines for sensitivity testing, because you can visually inspect the detector and check the Use both of these smoke detectors for detection circuits flash rate of the LED. If the calibration is out of factory- listed installed in areas where personnel are present. The range, the LED on the detector double flashes once every D7050TH has an added fixed - temperature sensor. This 3 sec to 8 sec. Follow the instructions provided with the expands the detector application to confined areas where detector to clean it. The detector also sends a dirty chamber a fire increases air temperature slowly and where there is a report to the control panel. substantial increase in air temperature before the fire breaks confinement, such as furnace rooms, closets, and LED Operation other confined areas. When the detector is operating normally, the LED flashes once every 3 sec to 8 sec. In alarm, the detector flashes at least once per second. Magnetic Test Feature Test the detector's operation by placing the SMK -TM Test Magnet next to the detector's LED for three consecutive flashes. This causes the detector to send an alarm. www.boschsecurity.com 2 I D7050 Series Addressable Photoelectric Smoke,and Smoke Heat Detector Heads .. Certifications and Approvals Mechanical Properties Color- Off -white Region Certification Dimensions (diame- 4 in. x 1.3 in. (10.2 cm x 3.3 cm) Europe CE 89/336/EEC, EN55022: 1998, ter x D): EN50130-4: 1995, EN60950: 2000, Material: High- impact, fire - retardant ABS plastic EN61000 -3 -2, EN61000 -3 -3, EN61000-4 -2, EN61000 -4 -3, Power Requirements EN61000 -4 -4, EN61000 -4 -5, Current (alarm): 0.55 mA maximum EN61000 -4 -6, EN61000 -4 -11 — — ____...__..__..__._.___ —._ Current (standby): 0.55 mA nominal USA UL UROX: Smoke - Automatic Fire Detectors y — — — — (UL268andA), UROX7: Smoke - Automatic Power -u Time: 22 sec maximum p Fire Detectors Certified for Canada Voltage (minimum): 8 VDC peak from the multiplex bus (cULus) Trademarks FM Trademark names are used throughout this document. In CSFM 7272- 1615: 175 most cases, these designations are claimed as trademarks NYC -MEA 12 -92 -E, Vol. 14 or registered trademarks in one or more countries by their Hong Kong HKFSD respective owners. Rather than placing a trademark symbol in every occurrence of a trademark name, Bosch Security Systems, Inc. uses the names only in an editorial fashion and to the benefit of the trademark owner with no intention Installation /Configuration Notes of infringing the trademark. Compatible Products The following products are compatible with the D7050 Chamber Check is a registered trademark of Bosch Security Systems. Inc. in the United States. Smoke Detector and the D7050TH Smoke Heat Detector: Category Product ID Product Description Control Panels FPD -7024 FACP Ordering Information . • • D7024 FACP D7050 Addressable Photoelectric Smoke D7050 • D7024 -EXP FACP for export Detector Head Two -wire, UL Listed, open -area smoke detec- Detector Bases D7050 -B6 Two -wire base tor head for use with the FPD -7024 or D7024 Remote DRA -12/24 12/24 VDC remote annunciator Addressable Fire Alarm Control Panels and Annunciators DS7400Xi Control Panel; requires a D7050- Interface Modules D8125MUX Multiplex bus interface module B6 base. D7050TH Addressable Photoelectric D7050TH Smoke and Heat Detector Head Two -wire, UL Listed, open -area smoke detec- Parts Included tor head with a 135 °F (57°C) fixed tempera- ture heat sensor for use with the FPD -7024 or Cuant. Component D7024 Addressable Fire Alarm Control Panels 1 Detector head and DS7400Xi Control Panel; requires a 1 Literature pack D7050 B6 base. Accessories DRA -12/24 Remote Annunciator DRA -12/24 Technical Specifications (12/24VDC) Designed to provide remote annunciation of Environmental Considerations alarms when connected to the D7050 -B6 Mul- tiplex Detector Base Radio Frequency Interfer- No alarm or setup on critical frequencies in the DT -2 Detector Removal Tool DT -2 ence (RFI) Immunity: range of 26 MHz to 950 MHz for field strengths Use the DT -2 to remove, replace, or test the less than 50 V/m detector head Temperature +32 °F to +100 °F (0 °C to +38 °C) SMK -TM Test Magnet SMK -TM (normal operating): — — -- — — — Used to test detectors Note: The environment where these detectors are installed must be within the specified normal operating temperature limits. Fire Alarm Systems I FMM -7045 Series Multiplex Addressable Manual Stations BOSCH Invented for life FMM -7045 Series Multiplex Addressable Manual Stations • Easy addressing with rotary switches - -- • Low current draw FIRE 0 FIRE FIRE ;I FIRE ► Key-lock reset • Replaceable scored acrylic breakrod option PUSH • Terminal connections PULL PULL ► ADA compliant • UL Listed `—� - BOSCH BOSCH The FMM -7045 Series Multiplex Manual Stations are UL Functions Listed fire alarm initiating devices that can be connected Alarm Action along with other multiplex devices on the D7039 Multiplex Expansion Module. The FPD-7024 or D7024 Addressable The single- action FMM -7045 has a white pull -down lever in Fire Alarm Control Panel (FACP) supervises the entire its center. The dual- action FMM- 7045 -D has a white push multiplex loop, including the FMM-7045 or FMM 7045 D lever above the white pull-down lever in its center. Pulling manual stations, for troubles, alarms, and ground fault down the pull -down lever latches it into place and sends an conditions. Because each manual station occupies only one alarm signal to the control panel over the multiplex bus. The address on the multiplex bus, it can be addressed for any pull -down lever cannot be reset unless the correct key is point within the 9 to 255 range allowed by the multiplex inserted into the manual station's lock and the unit is expansion module. opened. The latching lever can then be restored to its normal position. These manual stations are generally installed near building exits such as stairways and doors, allowing persons evacuating the building to activate the fire alarm. They have Certifications and Approvals optional scored acrylic breakrods and a pull handle that locks in the activated position, to allow easy identification of alarm activation points. Region Certification These manual stations are high - quality units constructed USA UL UNIU: Boxes, Non -Coded (UL38) entirely of non -toxic materials. They have a low profile and CSFM 7150 -1615: 122 rounded edges to fit most design applications. All NYC -MEA 12 -92 -E, Vol. 14 components are painted or have plated surfaces to inhibit corrosion. Non - corroding screw terminals are provided for ADA Complies with Americans with Disabilities wire connections. They are manufactured in conformance Act ADA 4.28.3 with the standards set forth in the Americans with NFPA Complies with National Fire Protection As Disabilities Act (ADA). sociation NFPA 72 www.boschsecurity.com 2 I FMM -7045 Series Multiplex Addressable Manual Stations Installation /Configuration Notes Technical Specifications Compatibility Information Environmental Considerations The FMM-7045 Series Multiplex Manual Stations are . compatible with a FPD -7024 FACP or a D7024 FACP with Environment: Dry, indoor firmware revision 2.0 or greater with a D7039 Multiplex Radio Frequency No alarm on critical frequencies in the range Expansion Module. Interference (RFI) from 26 MHz to 950 MHz at field strengths Immunity: less than 30 V /m. Addressing Temperature (Operating): +32 °F to +120°F (0°C to +49 °C) Addresses are set using three rotary switches. Refer to the D7024 FACP Operation and Installation Guide (P /N: 31499) Mechanical Properties or the FPD -7024 Operation and Installation Guide (P/ Dimensions (H xW x D): 4.75 in. x 3.75 in. x 3.25 in. N FO10008458) and the FMM -7045, FMM- 7045 -D Multiplex _ (12 cm x 9.5 cm x 8.2 cm) Addressable Manual Stations Installation Instructions (P/ Material: Die cast zinc alloy and steel N: F010001402) for programming information. Power Requirements Mounting The FMM -7045 manual stations are for indoor use only. Current Draw (Mux Bus Alarm: 0.55 mA Average): Standby: 0.55 mA Note If a pull station is needed for outdoor use or in Voltage (Operating): 12 VDC nominal (provided by the MUX bus) an unheated area, use an FMM -100 Series Pull Station rated for the environment and wired to a multiplex module within the interior of the building. ; Ordering Information FMM -7045 Single-Action Manual Station FMM -7045 The FMM -7045 manual stations flush or surface mount on a A UL Listed fire alarm initiating device that can standard four -inch square back box with a single -gang mud be connected, along with other multiplex de- ring so that the total depth of the box is at least 2.25 in. vices, on the D7039 Multiplex Expansion Mod- (5.7 cm). ule and is supervised by the FPD -7024 or D7024 Addressable FACP Note The FMM-7045 does not fit an FMM- 100BB-R FMM - 7045 -D Double - Action Manual FMM- 7045 -D Back Box. Station Wiring A UL Listed fire alarm initiating device that can g be connected, along with other multiplex de- The terminal block accepts wiring up to 12 AWG (2.3 mm) vices, on the D7039 Multiplex Expansion Mod- in diameter. Refer to the D7039 Installation Instructions (Pt ule and is supervised by the FPD -7024 or N: 38685) for multiplex wiring information. D7024 Addressable FACP Accessories - - - - -.— - -- D102 Replacement Key D102 Parts Included Replacement key ( #1358) for the D101 lock. FMM -100GR Scored Acrylic Break Rods FMM -100GR Guard. Component Scored acrylic rods (12 per package) 1 Manual station 1 FMM -100GR Scored Acrylic Breakrod 1 D102 Key (1358) 1 Literature pack Americas, Europe, Middle East, Africa, Asia-0aclfic, Represented by Bosch Security Systems, Inc. Bosch Security Systems B V Robert Bosch (SEA) Pte Ltd, Security Systems • 130 Pennton Parkway P 0. Box 80002 11 Bishan Street 21 Fairport, New York, 14450, USA 5600 JB Eindhoven, The Netherlands Singapore 573943 Phone .1 800 289 0096 Phone: • 31 40 2577 284 Phone: .65 6258 5511 Fax: .1 585 223 9180 Fax.•31 40 2577 330 Fax •65 6571 2698 security salos®us.bosch corn emea secuntysystemsebosch corn apr.securitysystemsebosch corn • www.boschsecurity.us www.boschsecurity corn www boschsecurlty corn O Bosch Security Systems Inc. 20101 Data subject to change without notice T19530410351 Cur en-US, V9, 4 Jul 2010 Fire Alarm Systems I D7044 Multiplex Single -input Module BOSCH Invented for life D7044 Multiplex Single -input Module • Use with D7024, DS9400M, or FPD -7024 Addressable FACPs • Fits into a standard double -gang or four -inch square h•; back box • Easy addressing using rotary switches • Low current draw • UL Listed • The D7044 Multiplex Single -input Module connects a • Certifications and Approvals normally -open (NO) contact to the multiplex bus of a — D7024, DS9400M, or FPD-7024 Addressable Fire Alarm Region Certification Control Panel (FACP). Use the D7044 supervised input in a USA UL AMCX: Central Station Alarm Units Class B configuration. All operating power for the input module is drawn from the FACP. (UL1610, UL1635), AOTX: Local Alarm Units (UL464, UL609), APAW: Police Note D7024 and DS9400M are not listed under Station Alarm Units (UL365, UL464), and UL864, 9th edition. NBSX: Household Burglar Alarm System Units (UL1023) Rotary switches allow convenient address setting. UL864, 9th edition An on -board status LED on the module indicates normal, FM alarm, and trouble conditions and is visible on the module or on an attractive, low- profile faceplate. CSFM 7165-1615: 147 7165 - 1615:227 NYC -MEA 12 -92-E, Vol.14 Installation /Configuration Notes Compatible Products The following products are compatible with the D7044 Multiplex Single -input Module: • www.boschsecurity.com 2 I D7044 Multiplex Single-input Module Category Product ID Product Description Mechanical Properties • A Control D7024 Addressable FACP Color: White Panels D7024 -EXP Addressable FACP for export P Dimensions: 4.3125 in. (10.9 cm) square by 1.0625 in. (2.7 cm) deep DS9400M Addressable FACP Material: ABS plastic FPD-7024 Addressable FACP Weight: 3.9 oz (110 g) Modules D7039 Multiplex expansion module Power Requirements (supplied from FACP's MUX bus) Mounting Mount the D7044 on a double -gang or four -inch square back Current: 0.55 mA box. Voltage (minimum): 8 V peak (12 VDC nominal) Wiring Make connections to the terminals on the rear of the 07044. - • - • - - - • • - - - . - All terminals can accommodate up to 12 AWG (2.3 mm) Ordering Information wire; however, follow wiring guidelines specified by the D7044 Multiplex Singleinput Module D7044 National Electrical Code (NFPA -70). All wiring is power Connects a normally-open (NO) contact to the limited and supervised. multiplex bus of a D7024, DS9400M, or FPD-7024 Addressable FACP Note Supervise the input loop with the supplied EOL resistor. Parts Included Quant. Component 1 D7044 module 1 2.21 k0 end -of -line (EOL) resistor (P /N: 25899) 1 Literature pack 1 1 Hardware pack • Technical Specifications Circuit Designation MUX Bus: Supervised Class A (Style 6) SLC or Class B (Style 4) SLC Input: Supervised Class B (Style B) IDC Environmental Considerations Environment: Indoor, dry Relative Humidity: Up to 93% non - condensing Temperature (operating): +32 °F to +120 °F (0 °C to +49 °C) Input Type: One normally -open (NO) contact input supervised by a 2.21 kO EOL resistor (P /N: 25899) Americas, Europe, Middle East, Africa: Asia - Pacific, Represented by Bosch Security Systems, Inc Bosch Security Systems B.V. Robert Bosch (SEA) Pte Ltd, Security Systems 130 Pennton Parkway P.O Box 80002 11 Bishan Street 21 Fairport, New York, 14450, USA 5600 JB Eindhoven, The Netherlands Singapore 573943 Phone. •1 800 289 0096 Phone I. 31 40 2577 284 Phone •65 6258 5511 Fax..1 585 223 9180 Fax:.31 40 2577 330 Fax..65 6571 2698 security.sales®us.bosch,com emea.secuntysystems®bosch corn apr secuntysystemss bosch corn www.boschsecunty us www boschsocunty com www boschsecurity com O Bosch Security Systems Inc 20101 Data subject to change without notice • 713124263791 Cur en-US. V6, 4 Jul 2010 Fire Alarm Systems I D7044M Multiplex Mini Single -input Module (�� BO SCH (---\ ... . . • . Invented for life • D7044M Multiplex Mini Single -input Module r - — -- — ► Use with D7024, DS9400M, or FPD -7024 Addressable — —.. .. FACPs ®_� I j • Fits into a standard single -gang back box o n o L • Easy addressing using rotary switches , 2 9 1 e 1 �• - "' °°W` ? 8 n 2 8. 2 • Low current draw x a- D59103 '. 0 7 3 7 '6 3 ' 2 1 .8 8 6 a e 8 a • • UL Listed i — - ) TENS • DES . j The D7044M Multiplex Mini Single -input Module connects Category Product ID Product Description a normally open (NO) contact to the multiplex bus of a Control D7024 Addressable FACP D7024, DS9400M or FPD -7024 Addressable Fire Alarm Panels D7024 -EXP Addressable FACP for export Control Panel (FACP). Use the D7044M supervised input in a Class B configuration. All operating power for the input DS9400M Addressable FACP module is drawn from the FACP. FPD-7024 Addressable FACP Rotary switches allow convenient address setting. Modules D7039 Multiplex expansion module Note The D7024 is not listed under UL864, 9th Mounting edition. The D7044M fits in a single -gang back box to which the device it is monitoring is attached. Wiring — Connections for the D7044M are made using the 16 AWG Certifications and Approvals — — -- — - - - - - - - - - -- (1.5 mm) flying leads from the device. All wiring is power Region Certification limited and supervised. USA UL UL864, 9th edition Note Do not use shielded wire. FM Note Supervise the input loop with the supplied EOL CSFM 7165-1615: 147 resistor. 7165 - 1615:227 NYC -MEA 12 -92-E, Vol. 14 — - - . . . Parts Included Quant. Component Installation /Configuration Notes _ _ . 1 D7044M module Compatible Products 1 2.21 kfl end-of -line (EOL) resistor (P /N: 25899) The following products are compatible with the D7044 1 Literature pack j Multiplex Single -input Module: www.boschsecurity.com 2 I D7044M Multiplex Mini 'Single input Module • Technical Specifications Circuit Designation MUX Bus: Supervised Class A (Style 6) SLC or Class B (Style 4) SLC Input: Supervised Class B (Style B) IDC Environmental Considerations Environment: Indoor, dry Relative Humidity: Up to 93% non-condensing Temperature (operating): +32 °F to +120 °F (0 °C to +49 °C) Input Type: One normally -open (NO) contact input supervised by a 2.21 kf) EOL resistor (P /N: 25899). Mechanical Properties Color: White Dimensions (HxWxD): 1.5625 in. x 2.75 in. x 0.6875 in. (4 cm x 7 cm x 1.75 cm) Material: ABS plastic Weight: 2.9 oz (82 g) Power Requirements (supplied from FACP's MUX bus) Current: 0.55 mA Voltage (minimum): 8 V peak (12 VDC nominal) [ Or d ering Information • D7044M Multiplex Mini Single -input D7044M Module Connects a normally -open (NO) contact to the multiplex bus of a D7024, DS9400M or FPD -7024 Addressable FACP Americas, Europe, Middle East, Africa, Asia•PaelRcs Represented by Bosch Security Systems, Inc Bosch Security Systems B.V. Robert Bosch (SEA) Pte Ltd, Security Systems 130 Perinton Parkway P.O. Box 80002 11 Blshan Street 21 Fairport, New York. 14450, USA 5600 JB Eindhoven, The Netherlands Singapore 573943 Phone. .1 800 289 0096 Phone • 31 40 2577 284 Phone +65 6258 5511 Fa.. +1 585 223 9180 Fax. .31 40 2577 330 Fax: •65 6571 2698 security sales ®us bosch.com emea secuntysystems ®bosch corn apr.secuntysystemsebosch.com www.boschsecurity.us www.boschsecurlty.com www.boschsecurlty com O Bosch Security Systems Inc. 20101 Data subject to change without notice 71312435979 I Cur: en•US, V6, 4 Jul 2010 Fire Alarm Systems I D7052 Multiplex Dual -input Module BOSCH Invented for life D7052 Multiplex Dual -input Module • Use with D7024, DS9400M, or FPD -7024 Addressable FACPs • Fits into a standard double-gang or four -inch square 3 back box • • Easy addressing using rotary switches � • Low current draw ; • ► UL Listed The D7052 Multiplex Dual -input Module connects Installation /Configuration Notes normally -open (NO) contacts to the multiplex bus of a Compatible Products D7024, DS9400M, or FPD -7024 Addressable Fire Alarm Control Panel (FACP). Use the D7052 for two The following products are compatible with the D7052 Class B (Style B) supervised inputs or one Class A (Style D) Multiplex Dual -input Module: input. All operating power for the input module is drawn Category Product ID Product Description from the FACP. Control D7024 Addressable FACP Note The D7024 and DS9400M are not listed under Panels D7024 -EXP Addressable FACP for export UL864, 9th edition. DS9400M Addressable FACP Rotary switches allow convenient address setting. FPD -7024 Addressable FACP An on -board status LED on the module indicates normal, Modules D7039 Multiplex expansion module alarm, and trouble conditions and is visible on the module Mounting or on an attractive, low- profile faceplate. Mount the D7052 on a double -gang or four -inch square back box. Wiring Certifications and Approvals Make connections to the terminals on the rear of the D7052. All terminals can accommodate up to 12 AWG (2.3 mm) Region Certification wire; however, follow wiring guidelines specified by the USA UL UL864, 9th edition National Electrical Code (NFPA -70). All wiring is power FM limited and supervised. CSFM ' 7165-1615: 147 Note Do not use shielded wire. 7165- 1615:227 Note Supervise Class B input loops with the NYC -MEA 12 -92 -E, Vol. 14 supplied EOL resistors. A Class A loop does not require an EOL resistor. www.boschsecurity.com 2 I D7052 Multiplex Dual -input Module, Parts Included Quant. Component • 1 D7O52 module 2 2.21 kfl end -of -line (EOL) resistors (P /N: 25899) 1 Literature pack 1 Hardware pack Technical Specifications • Circuit Designation MUX Bus: Supervised Class A (Style 6) SLC or Class B (Style 4) SLC Input: Supervised Class A (Style D) IDC or Class B (Style B) IDC Environmental Considerations Environment: Indoor, dry Relative Humidity: Up to 93% non-condensing Temperature (operating): +32 °F to +120 °F (0 °C to +49°C) Inputs Type: Two normally -open (NO) Class B (Style B) contact inputs or one Class A (Style D) contact input supervised by a 2.21 kfl EOL resistor (P /N: 25899) Mechanical Properties Color: White Dimensions: 4.3125 in. (10.9 cm) square by 1.0625 in. (2.7 cm) deep Material: ABS plastic Weight: 3.9 oz (110 g) Power Requirements (supplied from FACP's MUX bus) Current: •0.55 mA Voltage (minimum): 8 V peak (12 VDC nominal) Ordering Information D7052 Multiplex Dual -input Module D7052 Connects normally-open (NO) contacts to the multiplex bus of a D7O24, DS94O0M, or FPD -7024 Addressable FACP Amerlcasr Europe, Middle East, [Micas Asia-Pacifc R tad by Bosch Secunty Systems, Inc. Bosch Secunty Systems B V Robert Bosch (SEA) Pte Ltd, Security Systems 130 Perinton Parkway P.O Box 80002 11 Brshan Street 21 Fairport, New York, 14450, USA 5600 JB Eindhoven, The Netherlands Singapore 573943 Phone •1 800 289 0096 Phone. • 31 40 2577 284 Phone .65 6258 5511 Fax. +1 585 223 9180 Fax •31 40 2577 330 Fax: .65 6571 2698 security sales ®us bosch.com emea.securitysystems @bosch.com apr.secuntysystems®bosch com mew boschsecurlty us www.boschsecunty.com www.boschsecurlty.com 0 Bosch Secunty Systems Inc 20101 Data subject to change without notice T1312455947 ( Cur: en-US, V6, 4 Jul 2010 SYSTEM_ SENSOR® ` _ 4 -Wire Photoelectric Duct Smoke Detector . , � The InnovairFlex" Series are the only duct smoke detectors flexible enough to fit configurations from I t7t'1Ot'7I r • exY square to rectangular and everything in between. Features The InnovairFlex D4120 4 -wire photoelectric duct smoke • Photoelectric, integrated low Flow technology detector features a pivoting housing that fits both square and rectangular footprints and mounts to round or rectangular ductwork. • Air velocity rating from 100 ft/min to 4,000 ft/min (0.5 m/s to 20.32 This unit senses smoke in the most challenging conditions, operating m /sec) in airflow speeds of 100 to 4,000 feet per minute, temperatures • Versatile mounting options. square or rectangular configuration of —4 °F to 158 °F, and a humidity range of 0 to 95 percent (non- • Plug -in sensor offers superb false alarm immunity and the latest condensing). A plug-in sensor head offers improved false alarm sensor technology immunity and simple installation, testing, and maintenance An improved cover design isolates the sensor head from the low-flow • Broad ranges for operating temperature ( -4 °F to 158 °F) and feature for simple maintenance humidity (0% to 95% non - condensing) • Patented sampling tube installs from front or back of the detector The InnovairFlex housing provides ample wiring space, a'✓< inch with no tools required conduit knockout, and built -in short circuit protection to prevent • damage to sensitive components during installation High contrast • Increased wiring space with a newly added 3/4-inch conduit terminal designations make wiring easy With its 2:1 sensor -to -power knockout capability, the power board of the D4120 may be used to monitor • One easy-access Test/Reset button and improved LED status a second sensor, D4S, simultaneously (i.e., supply and return side) • Patented interconnect feature for multi-fan shutdown As many as 50 InnovairFlex detectors can be interconnected. When one unit senses smoke, all interconnected detectors will switch • New high contrast terminal designations their relays, only the detector sensing smoke will go into alarm, thus • Built -in short circuit protection from operator wiring errors pinpointing the fire source. • Field selectable settings for configuring the detector An easy-access Test/Reset button makes it possible to test the unit • Two DPDT Form -C relay contacts with the cover on. Three DIP switches can be used to configure field • 24 VAC/DC or 120 VAC selectable settings: cover tamper delay, number of sensors to be controlled, and shut down on trouble option. Each power board • Backward compatibility with existing Innovair products, including has two LEDs that can be used to indicate the status of connected remote accessories sensors, and a quick reference imprinted on the cover explains the LED status indications (Standby, Maintenance, Trouble, and Alarm) The InnovairFlex duct smoke detector can be customized to meet local codes and specifications without additional wiring. The new InnovairFlex product line is compatible with all previous Innovair Agency Listings models, including remote test accessories. WARNING: Duct smoke detectors are NOT a substitute for open ® MSS area smoke detectors; NOT a substitute for early warning detection; LISTED APPROVED approved NOT a replacement for a building's regular fire detection system. 5911 3029700 3242.1653202 2202 Refer to NFPA 72 and 90A for additional information. InnovairFlex Duct Smoke Detector Specifications Arch itectural /Engineering Specifications - ' The air duct smoke detector shall he a System Sensor InnovairFlex' D4120 Photoelectric Duct Smoke Detector The detector housing shall be UL listed per UL 268A specifically for use in air handling systems.The flexible housing of the duct smoke detector fits multiple footprints from square to rectangular The detector shall operate at air velocities of 100 feet per minute to 4000 feet per minute (0 5 to 20.32 meters/second) The unit shall be capable of controlling up to 50 air handling systems when Interconnected with other detectors The detector shall be capable of providing a trouble signal in the event that the front cover is removed It shall be capable of local testing via magnetic switch, test button on the cover, or remote testing using the SSK451 Multi - Signaling Accessory or the RTS451 KEY Remote Test Station. Terminal connections shall be of the strip and clamp method suitable for 12 -18 AWG wiring. Physical Specifications _ _ , Size: (Rectangular Dimensions) 14.38 in (37 cm) Length, 5 in (12.74 cm) Width, 2 5 in (6.36 cm) Depth (Square Dimensions) 7 75 in (19.7 cm) Length, 9 in (22 9 cm) Width; 2.5 in (6 35 cm) Depth Weight 2 5 Ibs (1 14 kg) Operating Temperature Range: D4120 & D4S -4° to 158 °F ( -20° to 70 °C), D4P120 -40° to 158 °F (40° to 70 °C) Storage Temperature Range: D4120 & D4S. -22° to 158 °F ( -30° to 70 °C), D4P120 -40° to 158 °F (-40° to 70 °C) Operating Humidity Range: 0% to 95% relative humidity non - condensing Air Duct Velocity: 100 to 4000 ft/min (05 to 2032 m /sec) Electrical Ratings Power supply voltage: 20 -29VDC 24 VAC 50-660 Hz 120 VAC 50-660 Hz Input capacitance: 270 pF max 270 pF max. N/A Reset voltage: 3 0 VDC min. 2 0 VAC min. l O VAC min. Reset time: (with RTS451) 03 to 0 3 sec. 03 to 0 3 sec 03 to 0.3 sec Reset time: (by power down) 0 6 sec. max. 06 sec max. 0.6 sec. max Power up time: 35 sec. max. 35 sec. max. 35 sec max Alarm response time: 15 sec 15 sec. 15 sec Sensitivity Test: See detector label See detector label See detector label Current Requirements: (Using No Accessories) Max. standby current: 21 mA @ 24VDC 65 mA RMS @ 24VAC 60Hz 20 mA RMS @ 120VAC 60Hz Max. alarm current: 65 mA @ 24VDC 135 mA RMS @ 24VAC 60Hz 35 mA RMS @ 120VAC 60Hz ( Contact Ratings Alarm initiation contacts: (SPST) 2.0A @ 30 VDC (resistive) Alarm auxiliary contacts: (DPDT) 10A @ 30 VDC (resistive); 10A @ 250 VAC (resistive), 1/2 HP @ 240 VAC ;' /a HP @ 120VAC Note: Alarm auxiliary contacts shall not be connected to initiating circuits of control panels Use the alarm initiation contact for this purpose. Supervisory contacts: (SPDT) 20A @ 30 VDC (resistive); 20A @ 125 VAC (resistive) Accessory Current Loads at 24 VDC Device Standby Trouble Alarm APA151 /APA451 12.5 mA n/a 30 mA Max MHR/MHW 0 mA n/a 29 mA Max RA100Z 0 mA n/a 12 mA Max. RTS151 /RTS151 KEY 0 mA/12 mA n/a 12 mA Max RTS2/RTS2 -AOS 3 OmA max 16 mA Max. with strobe 55 mA max; without strobe 30 mA max Note Any combination of accessories may be used such that the given accessory loads are 110 mA or less at the Aux output, and 50 mA or less at the Alarm output Installing the InnovairFlex Sampling Tube The InnovairFlex sampling tube may be installed from the front or back of the detector The tube locks securely into place and can be removed by releasing the front or rear locking tab (front locking tab shown below right) - 1 i ■ '� 1 K I A05-0414002 ' • • Wiring for 4-wire Duct Smoke Detector and Accessories POWER INPUTS (NOTE 1) POWER INPUTS (NOTE 1) ;4VAGD ® C � av � 9 10 9 10 OR OR AUXILIARY CONTACTS AUXILIARY CONTACTS FOR FAN SHUTDOWN, ETC. (NOTE 2) FOR FAN SHUTDOWN, ETC. (NOTE 2) AUXA AUXB AUXA AUX B N N N N �. 18 17 B 18 7 Tail 8 18 7 EOL RESISTOR SPECIFIED BY SUPERVISORY CONTACTS SUPERVISORY Y CONTACTS PANEL (NOTE 3) MANUFACTURER su SUP .O SUEC. SUP O. ULJFM LISTED 3 1a 3 10 4-WIRE CONTROL PANEL - y I I I ALARM 4 �� ALARM C. ALARM o el ALARM C. ALARM INITIATION INITIATION INITIATION CONTACTS CONTACTS LOOP \ (NOTE 4) (NOTE 4) 6 0 ALARM N.O. 6 0 ALARM N.O. i I 1 ' -- FIRST DETECTOR IN THE LOOP LAST DETECTOR IN THE LOOP NOTE 1: 24V Power Inputs accept a non - polarized 24VDC or 24VAC 50 -60Hz NOTE 3: Supervisory contacts shown in standby position. Open contacts • 120VAC Power Inputs accept only 120VAC 50 -60Hz. Connect power indicate a trouble condition to the panel See specifications for source to appropriate terminals of each detector See specifications contact ratings. for additional power supply information. NOTE 4: Alarm Initiation contacts shown in standby position Closed NOTE 2: Auxiliary contacts shown in standby position. Contacts switch contacts indicate an alarm condition to the panel. See specifications during alarm as indicated by arrows. Auxiliary contacts are not to for contact ratings. be used for connection to the control panel. See specifications for contact ratings. *Please refer to the corresponding installation manual for accessory wiring diagrams • Important Notes on 2:1 Sensor -to -Power Capability • 2:1 sensor -to -power capability is not available for all Innovair lex models. The feature is only available on the D4120 4 -wire conventional models • 2 sensor -to -power capability can be enabled using one D4120 and one D4S, or two D4S and one D4P120 Important Interconnect Notes • When using the interconnect feature, all interconnected units must be powered using the same independent supply. • Polarity must be maintained throughout the interconnect wiring. Connect the INT+ terminal on unit 1 to the INT+ terminal on unit 2 and so on. Similarly, connect the INT /AUX- terminal on unit 1 to the INT /AUX- terminal on unit 2 and so on. • Up to 50 D4120 units, 50 D4P120 units, or SO units of combination may be interconnected. • Up to 10 DH 1 OOACDC units may be interconnected. Please note that each of the 9 DH100ACDC units interconnected maybe replaced by three D4P120 units. Therefore, when using the interconnect feature a single DH100ACDC can drive either 9 DH100ACDCs or 27 D4120 units. j • NOTE: Alarm can be reset only at the initiating device and not at the devices interconnected. A05-0414-002 ThSYSTEM SENSOR® • 4 -Wire Photoelectric Duct — Smoke Detector _ r�i r JL- The lnnovairFlex" Series are the only duct smoke detectors flexible enough to fit configurations from I,,,,o,�x, square to rectangular and everything in between. Features The lnnovairFlex D4120 4 -wire photoelectric duct smoke • Photoelectric, integrated low flow technology detector features a pivoting housing that fits both square and rectangular footprints and mounts to round or rectangular ductwork. • Air velocity rating from 100 ft/min to 4,000 ft/min (0.5 m/s to 20.32 This unit senses smoke in the most challenging conditions, operating m /sec) in airflow speeds of 100 to 4,000 feet per minute, temperatures • Versatile mounting options: square or rectangular configuration of —4 °F to 158 °F, and a humidity range of 0 to 95 percent (non- • Plug -in sensor offers superb false alarm immunity and the latest condensing). A plug-in sensor head offers improved false alarm sensor technology immunity and simple installation, testing, and maintenance. An improved cover design isolates the sensor head from the low -flow • Broad ranges for operating temperature (-4 °F to 158 °F) and feature for simple maintenance. humidity (0% to 95% non - condensing) • Patented sampling tube installs from front or back of the detector The InnovairFlex housing provides ample wiring space, a 3 /a inch with no tools required conduit knockout, and built -in short circuit protection to prevent damage to sensitive components during installation. High contrast • Increased wiring space with a newly added' -inch conduit terminal designations make wiring easy. With its 2:1 sensor -to -power knockout capability, the power board of the D4120 may be used to monitor • One easy- access Test/Reset button and improved LED status a second sensor, D4S, simultaneously (i.e., supply and return side). • Patented interconnect feature for multi fan shutdown As many as 50 InnovairFlex detectors can be interconnected. When one unit senses smoke, all interconnected detectors will switch • New high contrast terminal designations their relays; only the detector sensing smoke will go into alarm, thus • Built -in short circuit protection from operator wiring errors pinpointing the fire source. • Field selectable settings for configuring the detector An easy- access Test/Reset button makes it possible to test the unit • Two DPDT Form -C relay contacts with the cover on. Three DIP switches can be used to configure field • 24VAC/DC or 120 VAC selectable settings: cover tamper delay, number of sensors to be controlled, and shut down on trouble option Each power board • Backward compatibility with existing Innovair products, including has two LEDs that can be used to indicate the status of connected remote accessories sensors, and a quick reference imprinted on the cover explains the LED status indications (Standby, Maintenance, Trouble, and Alarm). The lnnovairFlex duct smoke detector can be customized to meet local codes and specifications without additional wiring.The new lnnovairFlex product line is compatible with all previous Innovair Agency Listings models, including remote test accessories. ® ( 0) WARNING: Duct smoke detectors are NOT a substitute for open area smoke detectors; NOT a substitute for early warning detection; MSS LISTED APPROVED ICI approved NOT a replacement for a building's regular fire detection system. 5911 3029700 3242- 1653207 2202 Refer to NFPA 72 and 90A for additional information. InnovairFlex Duct Smoke Detector Specifications Architectural /Engineering Specifications The air duct smoke detector shall be a System Sensor InnovairFlex` D4120 Photoelectric Duct Smoke Detector. The detector housing shall be UL listed per UL 268A specifically for use in air handling systems. The flexible housing of the duct smoke detector fits multiple footprints from square to rectangular The detector shall operate at air velocities of 100 feet per minute to 4000 feet per minute (05 to 20.32 meters/second) The unit shall be capable of controlling up to 50 air handling systems when interconnected with other detectors. The detector shall be capable of providing a trouble signal in the event that the front cover is removed. It shall be capable of local testing via magnetic switch, test button on the cover, or remote testing using the SSK451 Multi - Signaling Accessory or the RTS451 KEY Remote Test Station. Terminal connections shall be of the strip and clamp method suitable for 12 -18 AWG wiring. Physical Specifications • Size: (Rectangular Dimensions) 14 38 in (37 cm) Length; 5 in (12 74 cm) Width; 2 5 in (6.36 cm) Depth (Square Dimensions) 7.75 in (19 7 cm) Length, 9 in (22.9 cm) Width; 25 in (6.35 cm) Depth Weight: 2.5 Ibs (1.14 kg) Operating Temperature Range: D4120 & D4S -4° to 158 °F ( -20° to 70°C); D4P120: -40° to 158 °F (-40° to 70 °C) Storage Temperature Range: D4120 & D4S. -22° to 158 °F ( -30° to 70°C); D4P120: -40° to 158 °F (-40° to 70 °C) Operating Humidity Range: 0% to 95% relative humidity non - condensing Air Duct Velocity: 100 to 4000 ft/min (0.5 to 20.32 m /sec) Electrical Ratings Power supply voltage: 20-29 VDC 24 VAC 50-60 Hz 120 VAC 50-60 Hz Input capacitance: 270 pF max. 270 pF max. N/A Reset voltage: 30 VDC min. 2.0 VAC min 10 VAC min. Reset time: (with RT5451) 03 to 0 3 sec. 03 to 0.3 sec. 03 to 0.3 sec Reset time: (by power down) 0.6 sec. max. 0.6 sec max. 0.6 sec. max Power up time: 35 sec. max. 35 sec. max. 35 sec max Alarm response time: 15 sec. 15 sec. 15 sec. Sensitivity Test: See detector label See detector label See detector label Current Requirements: (Using No Accessories) Max. standby current: 21 mA @ 24VDC 65 mA RMS @ 24VAC 60Hz 20 mA RMS @ 120VAC 60Hz Max. alarm current: 65 mA @ 24VDC 135 mA RMS @ 24VAC 60Hz 35 mA RMS @ 120VAC 60Hz Contact Ratings Alarm initiation contacts: (SPST) 2 OA @ 30 VDC (resistive) Alarm auxiliary contacts: (DPDT) 10A @ 30 VDC (resistive); 10A @ 250 VAC (resistive), Ih HP @ 240 VAC ; A HP @ 120 VAC Note: Alarm auxiliary contacts shall not be connected to initiating circuits of control panels Use the alarm initiation contact for this purpose Supervisory contacts: (SPDT) 2 OA @ 30 VDC (resistive); 2 OA @ 125 VAC (resistive) Accessory Current Loads at 24 VDC ° Device Standby Trouble Alarm APA151 /APA451 12.5 mA n/a 30 mA Max MHR/MHW 0 mA n/a 29 mA Max RA100Z 0 mA n/a 12 mA Max RTS151/RTS151KEY 0 mA/12 mA n/a 12 mA Max. RTS2/RTS2 -AOS 3 OmA max 16 mA Max with strobe: 55 mA max; without strobe 30 mA max Note Any combination of accessories may be used such that the given accessory loads are 110 mA or less at the Aux output, and 50 mA or less at the Alarm output Installing the InnovairFlex Sampling Tube The InnovairFlex sampling tube may be installed from the front or back of the detector. The tube locks securely into place and can be removed by releasing the front or rear locking tab (front locking tab shown below right) h ' (1 � j r . • ee r n I • t . _ _ + .` .ate .. A054.19-002 ' Wiring for 4 -wire Duct Smoke Detector and Accessories POWER INPUTS (NOTE 1) POWER INPUTS (NOTE 1) E c/o7 ov 9 10 9 10 OR OR AUXILIARY CONTACTS AUXILIARY CONTACTS FOR FAN SHUTDOWN, ETC. (NOTE 2) FOR FAN SHUTDOWN, ETC. (NOTE 2) AUX A AUX B AUX A AUX B N N N N. N• CO 18 17 B 16 6 6 17 S 16 7 .�� . . EOL RESISTOR SPECIFIED BY SUPERVISORY CONTACTS SUPERVISORY CONTACTS PANEL MANUFACTURER (NOTE 3) (NOTE 3) SU SUP O. SUPS. SUP O. UL/FM LISTED 3 14 3 14 4 -WIRE CONTROL PANEL • I I I ALARM a 0 ALARM C. ALARM a 0 ALARM C. ALARM INITIATION INITIATION INITIATION CONTACTS CONTACTS LOOP \ (NOTE 4) • (NOTE 4) �� • 5 ALARM N.O. 5 0 ALARM N.O. j I j I_— FIRST DETECTOR IN THE LOOP LAST DETECTOR IN THE LOOP c NOTE 1: 24V Power Inputs accept a non - polarized 24VDC or 24VAC 50 -60Hz. NOTE 3: Supervisory contacts shown in standby position. Open contacts 120VAC Power Inputs accept only 120VAC 50-60Hz. Connect power indicate a trouble condition to the panel. See specifications for source to appropriate terminals of each detector See specifications contact ratings. for additional power supply information. NOTE 4: Alarm Initiation contacts shown in standby position. Closed NOTE 2: Auxiliary contacts shown in standby position. Contacts switch contacts indicate an alarm condition to the panel. See specifications during alarm as indicated by arrows. Auxiliary contacts are not to for contact ratings be used for connection to the control panel. See specifications for contact ratings. *Please refer to the corresponding installation manual for accessory wiring diagrams. • • Important Notes on 2:1 Sensor -to -Power Capability • 2:1 sensor -to -power capability is not available for all InnovairFlex models. The feature is only available on the D41204 -wire conventional models. • 2:1 sensor - to-power capability can be enabled using one D4120 and one D4S, or two D4S and one D4P120. Important Interconnect Notes • When using the interconnect feature, all interconnected units must be powered using the same independent supply. • Polarity must be maintained throughout the interconnect wiring. Connect the INT+ terminal on unit 1 to the INT+ terminal on unit 2 and so on. Similarly, connect the INT /AUX- terminal on unit 1 to the INT /AUX- terminal on unit 2 and so on. • Up to 50 D4120 units, 50 D4P120 units, or 50 units of combination may be interconnected • Up to 10 DH100ACDC units may be interconnected. Please note that each of the 9 DH100ACDC units interconnected may be replaced by three D4P120 units. Therefore, when using the interconnect feature a single DH100ACDC can drive either 9 DH100ACDCs or 27 D4120 units. • NOTE: Alarm can be reset only at the initiating device and not at the devices interconnected. MS-0410-002 Accessories ( System Sensor provides system flexibility with a variety of accessories, including two remote test stations and several different means of visible and audible system annunciation. As with our duct smoke detectors, all duct smoke detector accessories are UL listed. yy t RTS151 UL 54011 RTS151KE_Y UL S2522 APA151 UL 54011 RTS2 -AOS UL 52522 ' �. a - +.ems► ■ We :: " i _ ___ . __ RA100Z UL 52522 MHW UL 54011 MHR UL 54011 AOS i Ordering Information Part No. Description D4120 4-wire photoelectric low -flow duct smoke detector Accessories - D4S 4-wire photoelectric sensor component only MHR Mini Horn, Red D4P120 4-wire photoelectric power board component only, MHW Mini Horn, White 24 VAC/DC, 120 VAC 2D51 4-wire conventional photoelectric sensor head P48 -21-00 End cap for metal sampling tubes DST1 Metal sampling tube duct width up to 1ft (03m) RA100Z Remote annunciator alarm LED DST1.5 Metal sampling tube duct widths 1 ft to 2 ft (03 to 06 m) RTS151 Remote test station DST3 Metal sampling tube duct widths 2 ft to 4 ft (0.6 to 1.2 m) RTS151 KEY Remote test station with key lock DST5 Metal sampling tube duct widths 4 ft to 8 ft (12 to 2.4 m) RTS2 - AOS Multi - signaling accessory DST10 Metal sampling tube duct widths 8 ft to 12 ft (24 to 3.7 m) APA151 Remote annunciator with piezo alarm DH400 OE -1 Weatherproof enclosure ETX Metal exhaust tube duct width 1 t (03m) MO2.04-00 Test magnet i SY TEIVI 3825 Ohio Avenue • St Charles, IL 60174 �� 0�105,�emSensor s$ SENSOR° ,yedrawn,souiearoauheing the dt >Rmemseet Phone: 800-SENSOR2 •Fax: 630 630-377-6495 anent product � oniaaioidudrg /10•12""'°" sheet A05-041 ?-007 • L10.11305 r (- �`T SYSTEM � � SENSOR® -.; R_zr.:; ry qi 'i! Duct Smoke -�~ • ` Detector Accessories „., �; k ccesso es � � ~ `' ; t. i % ' • 1 v I/L: i1 7 � J �y x S i : ' Y 1.', 1 Expand the versatility of the lnnovairFlef line of duct P w p smoke detectors with System Sensor notification and ' 'r ` r 1 5 ) # : test accessories. S Available Accessories Duct smoke detector accessories add functionality to the duct APA151 Piezo Annunciator smoke detection system by allowing quick, convenient inspections at eye level and effective audible and visible notification options. All MHR Mini -Horn, Red System Sensor duct smoke detectors and accessories are UL listed MHW Mini -Horn, White The APA151 piezo annunciator, which replaces the APA451 with RA100Z/RA100ZA Remote Annunciator a new, improved look, provides an audible alarm signal, a red LED ( i-- RTS151 Remote Test Station to indicate alarm status, and a green LED to indicate power status. RTS151KEY Remote Test Station with Key It is intended for use with System Sensor 4 -wire conventional duct • smoke detector applications without a system control panel, to RTS2 Multi - Signaling Accessory comply with NFPA 90A. AOS Add -On Strobe The MHR and MHW SpectrAlert' Advance mini -horns feature • RTS2 -AOS Multi - Signaling Accessory temporal or continuous tones at high and low volume settings. Their small footprint allows mounting to single -gang back boxes for applications where a small device is desired. The RA100Z and RA100ZA remote annunciators are designed for both conventional and intelligent applications. Their red LED provides visual indication of an alarm condition. The RTS151 and RTS151KEY remote test stations are automatic fire detector accessories designed to test duct smoke detectors from a convenient location For 4 -wire detectors, the RTS151KEY test station features a multi - colored LED that alternates between steady green and red. For 2 -wire detectors, the LED illuminates red for alarm. The RTS2 and RTS2 -AOS multi - signaling accessories are designed to work with InnovairFlex 4 -wire conventional duct smoke detectors. These accessories include a key switch that can be used to select one of two connected sensors to be tested, reset, or both by a push button switch. They also enable sensitivity measurements using Agency Listings the SENS -RDR sensitivity reader (sold separately). The AOS (Add -On T . ( 3 41:* � Strobe) is an optional accessory included with the RTS2 -AOS model. 0 j LISTED "MOVED Iiiiiil . Specifications, Duct Smoke Detector Accessories APA151 Piezo Annunciator RT5151 Remote Test Station Voltage Regulated 24 VDC Power Requirements Alarm LED: 2.8 to 32 VDC, 12 mA max. Operating Voltage 16 to 33 VDC Total Current. 105 mA max . Maximum Alarm Current 30 mA Test Switch 10 VA @ 32 VDC Temperature Range 0 °C to 49°C (32 °F to 120 °F) Reset Switch 10 VA @ 32 VDC Relative Humidity 10 to 93% non - condensing Alarm Response Time 40 seconds max Wire Gauge 12 to 18 AWG Temperature Range -10°C to 60 °C (14 °F to 140 °F) Dimensions 4.6"H x 2.9 "W x .45" D Relative Humidity 95% non - condensing MHR /MHW SpectrAlert' Advance Mini - Horns Wire Gauge 14 to 18 AWG Voltage Regulated 12 DC or FWR (Full Wave Rectified) Dimensions 4.8" H x 2.90 "W x 1.4" D or Regulated 24 VDC or FWR RTS151 KEY Remote Test Station with Key Operating Voltage 8 to 33 VDC Power Requirements Power LED (Green). 14 to 35 VDC, 12 mA max. (9 to 33 VDC with Sync•Circuit Module) Alarm LED (Red): 2 8 to 32 VDC, 12 mA max. Sounder Current Draw 22 mA RMS max. at 8 to 175 Volts DC Total Current 105 mA max. 17 mA RMS max at 8 to 17.5 Volts FWR Alarm Response Time 40 seconds max. 29 mA RMS max at 16 to 33 Volts DC Temperature Range -10 °C to 60 °C (14 °F to 140 °F) 25 mA RMS max at 16 to 33 Volts FWR Relative Humidity 95% non - condensing Temperature Range 0 °C to 49°C (32 °F to 120 °F) Wire Gauge 14 to 18 AWG Humidity Range 10 to 93% non - condensing Dimensions 4.6 "H x 2 75 "W x 1.8"D Nominal Sounder Frequency 3 kHz RTS2 and RTS2 - AOS Multi signaling Accessory Wire Gauge 12 to 18 AWG Voltage 20 to 29 VDC Dimensions 4.6"H x 2.9 "W x 045" D Power Requirements Standby: 3 0 mA max. RA1 00Z /RA100ZA Remote Annunciator Trouble. 16.0 mA max Voltage Range Conventional System: 3.1 to 32 VDC Alarm without strobe: 30 mA max. Intelligent System: 18 to 32 VDC Alarm with strobe. 55 mA max. Maximum Alarm Current 12 mA Sounder 85 dBA at ten feet Dimensions 46 "H x 2.8 "W x 1.3 "D Temperature Range -10 °C to 60 °C (14 °F to 140`F) � Relative Humidity 95% non-condensing Wire Gauge 14 to 22 AWG Dimensions 4.8 "W x 5.3 x 1.6"D For the very latest product specifications and listing information, please visit the System Sensor Web site at www.systemsensor.com. . t . 1 . :.. . a,�z; IY9"ii t r( i � �.F,, 7. /I fit . : ' r ': ,q RTS151 UL 54011 RTS151 KEY U L 52522 APA151 UL 54011 RTS2 -AOS UL 52522 0 i t f 1 - - RA100Z UL 52522 MHW UL 54011 MHR UL S4011 AOS 1. iT �+ sT1 3825 Ohio Avenue • St. Charles, IL 60174 nm n 02010sn1em$e1Sr �� SENSOR° e°0rod eQ1D l' eskrtsynertnmmeet Phone 800-SENSOR2 •Fax 630 377{i495 a itA1 product °d° •0° d°"° 30 9 "°° "" AOS-0 . vio • aw9 * $SENSOR SYSTE M ® • Selectable Output r1 i Horns, Strobes, and ;;� 1 ;„' Horn /Strobes SpectrAlert Advance selectable - output horns, strobes, and horn /strobes are rich with features guaranteed to cut installation times and maximize profits. SPECTRAlert akiaarraagrara The SpectrAlert Advance series of notification appliances is Features designed to simplify installations, with features such as plug in • Electrically compatible with existing SpectrAlert products designs, instant feedback messages to ensure correct installation of individual devices, and 11 field selectable candela settings for wall • Automatic selection of 12- or 24 -volt operation at 15 and 15/75 and ceiling strobes and horn /strobes. candela • Plug -in design When installing Advance products, first attach a universal mounting • Field selectable candela settings on wall and ceiling units: 15, 15/75, plate to a four -inch square, four -inch octagon or double -gang 30, 75, 95, 110, 115, 135, 150, 177, 185 junction box. The two -wire mounting plate attaches to a single -gang • Same mounting plate for wall- and ceiling -mount units junction box. • Shorting spring on mounting plate for continuity check before Next, connect the notification appliance circuit wiring to the SEMS installation terminals on the mounting plate. •Tamper resistant construction • Outdoor wall and ceiling products rated from -40 °F to 151°F Finally, attach the horn, strobe or horn /strobe to the mounting plate • Design allows minimal intrusion into the back box by inserting the product's tabs in the mounting plate's grooves. The • Horn rated at 88+ dbA at 16 volts device will rotate into position, locking the product's pins into the mounting plate's terminals. The device will temporarily hold in place • Rotary switch for horn tone and three volume selections with a catch until it is secured with a captured mounting screw. • Outdoor products UL listed to UL 1638 (strobe) and UL 464 (horn) outdoor requirements The SpectrAlert Advance series includes outdoor notification • Outdoor products rainproof per UL 50 (NEMA 3R) appliances. Outdoor strobes and horn /strobes (two wire and four wire) are available for wall or ceiling. Outdoor horns are available for • Compatible with MDL sync module wall only. All System Sensor outdoor products are rated between minus 40 degrees Fahrenheit and 151 degrees Fahrenheit in wet or dry applications. Agency Listings SIGNALING T1 7125-1653186 (Moor strobes) i L 4441> A lt_ 7300-1653 187 (outdoor strobes) C , r ` 7125.16531880wrn/wobel. approved C b°r1 / Wobes) USED APPROVED ICI 7135- 1653 189(hOmsalenes) 54011 3023572 MEM52-05{ 55512 53593 • SpectrAlert Advance Specifications Archi ect /En,gineer,5pecifikMions General SpectrAlert Advance horns, strobes and horn/strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4 -inch octagon back box or double -gang back box Two-wire products shall also mount to a single -gang 2 x 4 x 1% -inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync -Circuit Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Ciicuit Module, 12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts; 24 -volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full -wave rectified, unfiltered power supply. Strobes and horn/strobes shall have field- selectable candela settings including 15,15/75, 30, 75, 95, 110, 115, 135, 150, 177, 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary - signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range The strobe light shall consist of a xenon flash tube and associated lens/reflector system Hom /Strobe Combination The horn/strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn/strobe shall be wired as a primary- signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three - pattern and a non - temporal (continuous) pattern. These options are set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder. The horn on horn /strobe models shall operate on a coded or non -coded power supply. Outdoor Products SpectrAlert Advance outdoor horns, strobes and horn /strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fahrenheit. The products shall be listed for use with a System Sensor outdoor/weatherproof back box with half inch and three - fourths inch conduit entries. Synchronization Module The module shall be a System Sensor Sync -Circuit model MDL listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1Hz and horns at temporal three Also, while operating the strobes, the module shall silence the horns on horn/strobe models over a single pair of wires. The module shall mount to a 4" /6 x 4"/16x 2' /e -inch back box. The module shall also control two StyleY (class B) circuits or one Style Z (class A) circuit The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical /Electrical Specifications • Standard Operating Temperature 32 °F to 120°F (0°C to 49°C) K Series Operating Temperature —40°F to 151°F (-40°C to 66°C) Humidity Range 10 to 93% non-condensing (indoor products) Strobe Flash Rate 1 Flash per second Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR' Operating Voltage Range= 8 to 17.5 V (12V nominal) or 16 to 33 V (24 nominal) Input terminal wire gauge 12 to 18 AWG Ceiling mount dimensions (induding lens) 6.8" diameter x 2.5" high (173 mm diameter x 64 mm high) Wall mount dimensions (including lens) 5.61 x 4.7W x 2.5D (142 mm L x 119 mm W x 64 mm D) Hom dimensions 561_ x 4 7 W x 1 3U (142 mm L x 119 mm W x 33 mm D) Wall -mount back box skirt dimensions (BBS -2, BBSW -2) 5.91 x 5.0W x 2.2D (151 mm L x 128 mm W x 56 mm D) Ceiling -mount back box skirt dimensions (BBSC -2, BBSCW -2) 7 diameter x 2 25 high (180 mm diameter x 57 mm high) Wall -mount weatherproof back box dimensions (SA -WBB) 5.71 x 5.1W x 2.0 (145 mm L x 130 mm W x 51 mm D) Ceiling -mount weatherproof back box dimensions (SA -WBBC) 7.1 diameter x 2.0 high (180 mm diameter x 51 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non - regulated, time varying power source that is used on some power supply and panel outputs. 2. P S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd A05-0395-003 UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) UL Max. Horn Current Draw (mA RMS) 8 -17.5 Volts 16 -33 Volts 8 -17.5 Volts 16 -33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR ° Standard 15° 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15/75" 142 148 77 81 Temporal Medium 44 49 58 69 30' NA NA 94 96 Temporal Low 38 44 44 48 75° NA NA 158 153 Non- temporal High 57 56 69 75 95° NA NA 181 176 Non- temporal Medium 42 50 60 69 110 NA NA 202 195 Non - temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2 -wire Horn /Strobe, Standard Candela Range (15 -115 cd) 8 -17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non - temporal High 141 152 91 100 116 176 201 221 229 Non - temporal Medium 133 145 75 85 102 163 187 207 216 Non - temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non - temporal High 142 161 103 112 126 181 203 221 229 Non - temporal Medium 134 155 85 95 110 166 189 208 216 Non - temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (mA RMS), 2 -wire Horn /Strobe, High Candela Range (135 -185 cd) 16-33 Volts 16 -33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non - temporal High 255 270 303 309 Non - temporal High 233 248 275 281 Non - temporal Medium 242 259 293 299 Non - temporal Medium 219 232 262 267 Non - temporal Low 238 254 291 295 Non - temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures, listed candela Horn and Horn /Strobe Output (dBA) . ratings must be reduced in accordance with this table 8 -17.5 16-33 24 Volt Nominal Strobe Output (cd) Switch Volts Volts Reverberant Anechoic Listed Candela Candela rating at -40 °F Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 15 1 Temporal High 78 78 84 84 88 88 99 98 15/75 Do not use below 32 °F 2 Temporal Medium 74 74 80 80 86 86 96 96 30 3 Temporal Low 71 73 76 76 83 80 94 89 75 44 4 Non - temporal High 82 82 88 88 93 92 100 100 95 70 5 Non - temporal Medium 78 78 85 85 90 90 98 98 110 110 6 Non - temporal Low 75 75 81 81 88 84 96 92 115 115 7t Coded High 82 82 88 88 93 92 101 101 135 135 8' Coded Medium 78 78 85 85 90 90 97 98 150 150 9' Coded Low 75 75 81 81 88 85 96 92 177 177 'Settings 7, 8, and 9 are not available on 2 -wire horn /strobe 185 185 AOS-O395-003 • SpectrAlert Advance Dimensions r 1 .- 4.7" 2.5' 6 8" ii Die. 1.x.1 1I '■ .' le l ):, a 2 .5" 5.6' i ■I '1// i 111) . v _ Wall -mount horn /strobes Ceiling -mount horn /strobes A 2.25 7,1" 7.1- -1 2.0' DM. +- -5.05 2.23+1 _ Di a. I C o ® 0 pig OJto ♦Z. , / ` 5.98"1 ,I 5.7 c c o , , s .U 4 F t/ - • X 4,, o ® o p 0• -• I \ —' / ` It \ilkVire. r l.- 5.1"-d Wall back box skirt Ceiling back box skirt Wall weatherproof back box Ceiling weatherproof back box SpectrAlert Advance Ordering Information Model. .,Description ':_ , : ._. Model. ,.:. . Description ., , Wall Horn /Strobes Ceiling Hom /Strobes (contd.) P2R•t 2 -wire Horn/Strobe, Standard cdt, Red PC2W`t 2 -wire Horn/Strobe, Standard cd, White P2RH• 2 -wire Horn/Strobe, High cd, Red PC2WH•t 2 -wire Horn/Strobe, High cd, White P2RK• 2 -wire Horn/Strobe, Standard cd, Red, Outdoor PC4R 4 -wire Horn/Strobe, Standard cd, Red P2RHK• 2 -wire Horn/Strobe, High cd, Red, Outdoor PC4RH 4 -wire Horn/Strobe, High cd, Red P2W 2 -wire Horn/Strobe, Standard cd, White PC4RK 4 -wire Horn/Strobe, Standard cd, Red, Outdoor P2WH• 2 -wire Horn/Strobe, High cd, White PC4RHK 4 -wire Horn/Strobe, High cd, Red, Outdoor P4R• 4 -wire Horn/Strobe, Standard cd, Red PC4W 4 -wire Horn/Strobe, Standard cd, White P4RH• 4 -wire Horn/Strobe, High cd, Red PC4WH 4 -wire Horn/Strobe, High cd, White P4RK 4 -wire Horn/Strobe, Standard cd, Red, Outdoor Ceiling Strobes P4RHK 4 -wire Horn/Strobe, High cd, Red, Outdoor SCR* Strobe, Standard cd, Red P4W 4 -wire Horn/Strobe, Standard cd, White SCRH• Strobe, High cd, Red P4WH• 4 -wire Horn/Strobe, High cd, White SCRK Strobe, Standard cd, Red, Outdoor Wall Strobes SCRHK Strobe, High cd, Red, Outdoor SR" Strobe, Standard cd, Red SCWt Strobe, Standard cd, White SRH•t Strobe, High cd, Red SCWH•t Strobe, High cd, White SRK Strobe, Standard cd, Red, Outdoor Horns SRHK Strobe, High cd, Red, Outdoor HR Horn, Red SW` Strobe, Standard cd, White HRK Horn, Red, Outdoor SWH• Strobe, High cd, White HW Horn, White Ceiling Horn /Strobes Accessories PC2R• 2 -wire Horn/Strobe, Standard cd, Red BBS -2 Back Box Skirt, Wall, Red PC2RH• 2 -wire Horn/Strobe, High cd, Red BBSW -2 Back Box Skirt, Wall, White PC2RK 2 -wire Horn/Strobe, Standard cd, Red, Outdoor BBSC -2 Back Box Skirt, Ceiling, Red PC2RHK 2 -wire Horn/Strobe, High cd, Red, Outdoor BBSCW -2 Back Box Skirt, Ceiling, White Notes: • Add ' -P'to model number for plain housing (no FIRE marking on cover), eg , P2R -P t Add ' -SP'to model number for'FUEGO" marking on cover, e g, P2R -SP #'Standard cd; refers to strobes that include 15,15/75, 30, 75, 95,110, and 115 candela settings 'High cd; refers to strobes that include 135, 150, 177, and 185 candela settings. All outdoor units end in in'K"include a weatherproof back box . • ``� �is/e M M �'I 01006 System Senior � ` SENSOR e 3825 Ohio Avenue • St Charles, IL 60174 Product spKlhd6du sutIM to Nave x+CWn name Visit systemsaaamom for .-V /11� Phone 800- SENSOR2 • Fax 630-377-6495 cutest i n: duct fo rm an o` " `°dng the dtest"a"°nof0"' data sheet A05.0395-003. 12/06• !1676 • ` y `W : ; N 'V.' S.'4.. \Vi' i •'' :1 .V, ! \Y" \ .1�r ''iV; / ,i- .1 /W"..,:`,9 ;N /� \ ' r i( r . - V,) i•. .V ' . „ `/f1 I .``/ V'. :V�`�,/� ,�. ! 1V. W• �!- �\,� J. V' V. �r'aw /\V'�Y!�`�;.' v' \`r:.VC�V'dl �! P! /_lSl;Y �., , „W,: v , • , ..4.1:0 fli _ 1 : 1 .._1.4.. 1i! _lq !._U1„.1 111:;�4.'.tu 4l._ , t� a !,f. 14: __'1f. ,' q u : :/.:. . is .i8 s. pi. `t _! ..;! .,u! ;Ii ”C, 4!.41 .0 "u. ,1c 1 4. a .: lir:.]J. Ali 'll ': "l6 Ni ?u .t ' - 1 � -�c:4 Applicant ID No: 108225 -001 �- ' i ® Underwriters Laboratories Inc. o Service Center No 1 ra; - ; ‹,- 1 >.! Northbrook, IL San Jose, CA Expires: 31- MAR -2011 - <'I.:. Melville, NY g V.1 A not - for - profit organization dedicated to public safety 5 ' F. '' ti 4:' and committed to service 4y : quality ` ` CERTIFICATE OF COMPLIANCE 1` Ali THIS IS TO CERTIFY that the Alarm Service Company indicated below is included by Underwriters i- , ,. 9.. Laboratories Inc. (UL) in its Product Directories as eligible to use the UL Listing Mark in connection with f < ; . ,zm Certificated Alarm Systems. The only evidence of compliance with UL's requirements is the issuance of a S,` cr, g UL Certificate for the Alarm System and the Certificate is current under UL's Certificate Verification Service. E' This Certificate does not apply in any way to the communication channel between the protected property and M ' tip any facility that monitors signals from the protected property unless the use of a UL listed or Classified Alarm , ..) fi3 © , 1 ,� Transport Company is specified on the Certificate.E l L Listed Service From: CHAMPAIGN IL (CHAMPAIGN) ,.: d Alarm Service Company: (108225 -001 E � ) Service Center: (108225 -001) 1 ..C) FE MORAN INC ALARM & MONITORING FE MORAN INC ALARM & MONITORING ' �r.E i � .t SERVICES SERVICES E •- .:, 4 201 W UNIVERSITY AVE 201 W UNIVERSITY AVE i 6. CHAMPAIGN IL 61820 CHAMPAIGN IL 61820 - k :) • 1I O `. The Alarm Service Company is Listed in the following Certificate Service Categories: T i File - Vol No. CCN Listing Category "1"e f lii c4 BP8111 -1 CVSG [Burglar Alarm Systems] Mercantile ' C ;) S8943 -1 UUFX [Signal and Fire Alarm Equipment and Services] (Protective . .4 . ) • Signaling Services) Central Station r' •<-1 ('' l Ems, 'i;: RNs Cdr, 1'•, L._, Ct Oia co `y 1 <^ ` **THIS CERTIFICATE EXPIRES ON 31- MAR - 2011 *** - r� "LOOK FOR THE UL ALARM SYSTEM CERTIFICATE” -;' Cte X. v . . Engineering anager 4, >. ® 2008 uL Form CS-CC 30- MAR -2010 t' <: ?'.rl, nt m '.n••.'tl :!'}- PI, ,rr',•t.:1 .f ;atr, . •' 71. .. '.nt T r'. m: . rn m 8 I . n :: PI. 'n, - n' ,n: �n ?I[: `lri.`� .,n7r_rr 1:7 "in, - r�:-r".!. r P',.' .. . '� )/U.AA1 / (A'cl/\ //\ AN Ikl'A\..4AYI \// t .: A\,i MrA . c. AAVA%^\ / AJY A m AA1 /Aj A) /AV /A�;A\/AJl�` J AI / A4 / A / A\ :/\'[.^ II. AVA\' ��FfA,' lA iIA. 'AvAVAl..;dsj /A ; "/.•�. Project Varibles Project Name: I Petsmart 1 Standby Hours: 124 I Extra arcwt capacity:I10% Project ID:I387 I Alarm Mins:15 I Voltage Drop:125% I Prepared By:IC.Messing I EOL Voltage (V):I16.0 Date:110 /22/2010 I FPD -7024 FACP Battery Calculator �I Circuit Tyke Standby Alarm & Type 1000 Ft. Per Circuit Ohms EOL %Drop Conventional 2 -wire Loops 0.000 0.176 #1a Solid 8.08 0 0.00 20.40 0.00 Smoke Power (Cony. 4 -wire devices) 0.000 0.000 #18 Solid 8.08 0 0.00 20.40 0.00% Aux Power 0.000 0.000 #18 Solid 8.08 0 0.00 20.40 0.00% NACs (Local #1) 0.000 0.000 #18 Solid 8.08 0 0.00 20.40 0.00% NACs (Local #2) 0.000 .0.000 #18 Solid 8.08 0 0.00 20.40 0.00% FPD -7024 Panel 0.200 0.200 0.981 (Amps) Total Output Power Required Total Standby Current (Amps) 0.358 0.623 Total Alarm Current (Amps) Standby Time In Hours 24 5 Alarm Time In Min 0 Total Standby AH Required 8.594 0.052 Total Alarm AH Required Total Combined AH Required 8.65 Multiply by Battery Derating Factor 10% Minimum Battery AmpHours Required 9.51 Page 1 of 1 ProProject ect Varibles Name:JPetsmart Standby Hours:l 24 Extra Circuit Capacity:110% Project ID: 3871 Alarm Mins:1 5 I Volt. Drop Warning: 125% Prepared By: 1C.Messing 1 EOL Voltage (V):116.0 Date: 110/22/2010 1 FPP- RNAC -8A-4C Battery Calculator Circuit: Conventional 2 -wire Loops Max STBY Current 0.0027 Amps with 10% Safety: Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 4 4- Please enter the number of Zones in use Totals 0.000 1 0.176 Circuit: Mux Bus Max Current with 0.09 Amps 10% Safety: Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 1 D7050 Photoelectric Smoke Detector /Base _ 0.001 0.001 0.001 0.001 5 D7044 Single Point Input Module 0.001 0.001 0.003 0.003 6 . D7044M Mini Single Point Input Module 0.001 0.001 0.003 0.003 1 D7052 Two Point Input Module 0.001 0.001 0.001 0.001 Totals 0.007 0.007 Circuit: Option Bus Max Current with 0.45 Amps 10% Safety: Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 1 1D7032 Eight Point LED Annunciator Expander 1 0.001 1 0.090 0.001 0.090 Totals, 0.001 0.090 Circuit: Expanders Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 1 107039 Multiplex Expander 1 0.150 1 0.150 0.150 0.150 Totals 0.150 0.150 r, • • Device: Quantity: Current Per Device: Stand By Current: Alarm Current: AL1002ULADA 1 Stand by: 90mA 0.09 Alarm: 175mA 0.175 Panel Current 0.09 0.175 Nac Circuit 1 2.138 2.138 Nac Circuit 2 1.209 1.209 Nac Circuit 3 0.221 0.221 Nac Circuit 4 0 Totals: 0.18 3.918 Stand by Hours: 24 4.32 Alarm Sounding 0.0833 0.3263694 Amp Hours Subtotal 4.6463694 AH Required 6.04028022 Voltage Drop Analysis Notification Appliances FCPS -24S8 Notification Appliance Circuit (3.0 amps) Source Voltage: 20.40 VDC Low Line Protected Premises: PETSMART Date: 10 -22 -10 Address: 7501 S.W. DARTMOUTH City: TIGARD State: OR Zip: 97223 Note: NAC 1 Prepared By: F.E. MORAN, INC. ALARM & MONITORING Phone: 586 - 228 -5788 • Address: 33341 KELLY RD. City: FRASER State: MI Zip: 48026 Current Distance (Feet) Circuit Voltage @ Each Device Device # PartNumber (amps) Between Total 10 AWG 12 AWG 14 AWG 16 AWG 18 AWG 1 PC2R115 0.2180 31 31 20.27 20.16 20.06 19.86 19.54 2 PC2R115 0.2180 55 86 20.06 19.78 19.51 . 18.99 18.17 3 PC2R75 0.1760 54 140 19.87 19.45 19.03 18.24 16.97 4 PC2R115 0.2180 42 182 19.74 19.22 18.70 17.71 16.14 5 PC2R115 0.2180 55 237 19.60 18.96 18.32 17.129 6 PC2R115 0.2180 55 292 19.48 18.74 18.01 16.63 14.42 7 PC2R115 0.2180 55 347 19.38 18.57 17.76 16.24 4-3..80 8 PC2R115 0.2180 55 402 19.31 18.44 17.57 -1--5,94 43.3 -3 9 PC2R115 0.2180 55 457 19.26 18.36 17.45 15.75 13.02 10 PC2R115 0.2180 55 512 19.24 18.31 17.39 15.65 12 6 Total Current: 2.1380 % Voltage Drop: 5.68 10.23 14.78 23.30 36.94 Go Go Go No Go No Go Strikethrough indicates a value below the device's minimum voltage at indicated location and wire gauge. These calculations assume a worst -case source voltage as measured by UL with the batteries depleted to 20.4 volts. Under AC power and for most of the drain cycle of the batteries, the circuit voltages will be substantially higher and thus, would support a greater number of devices. A device's minimum operating voltage is derived from the UL- requirement that it • work down to 80% of its rated (published) minimum operating voltage. . 10/22/2010 1 Voltage Drop Analysis Notification Appliances FCPS -24S8 Notification Appliance Circuit (3.0 amps) Source Voltage: 20.40 VDC Low Line Protected Premises: PETSMART Date: 10 -22 -10 Address: 7501 S.W. DARTMOUTH City: TIGARD State: OR Zip: 97223 Note: NAC 2 Prepared By: F.E. MORAN, INC. ALARM & MONITORING Phone: 586- 228 -5788 • Address: 33341 KELLY RD. City: FRASER State: MI Zip: 48026 Current Distance (Feet) Circuit Voltage @ Each Device Device # PartNumber (amps) Between Total 10 AWG 12 AWG 14 AWG 16 AWG 18 AWG 1 SR15 0.0660 12 12 20.37 20.35 20.32 20.28 20.21 2 SR15 0.0660 8 20 20.35 20.31 20.28 20.21 20.09 3 PC2R15 0.0790 23 43 20.30 20.23 20.15 20.00 19.77 4 PC2R75 0.1760 28 71 20.25 20.13 20.00 19.77 19.41 5 PC2R75 0.1760 11 82 20.23 20.09 19.96 19.70 19.29 6 PC2R75 0.1760 38 120 20.18 20.00 19.83.. 19.50 18.97 7 P2R30 0.1070 42 162 20.14 19.93 19.73 ; 19.34 18.71 8 SR15 0.0660 14 176 20.13 19.91 19.70 ' 19.29 18.65 9 PC2R115 0.2180 113 289 20.06 19.79 19.52 19.02 18.21 10 P2R15 0.0790 58 347 20.05 19.78 19.50 - 18.98 18.15 Total Current: 1.2090 % Voltage Drop: 1.70 3.05 4.41 6.95 11.02 Go Go Go Go Go Strikethceugh indicates a value below the device's minimum voltage at indicated location and wire gauge. These calculations assume a worst -case source voltage as measured by UL with the batteries depleted to 20.4 volts. Under AC power and for most of the drain cycle of the batteries, the circuit voltages will be substantially higher and thus, would support a greater number of devices. A device's minimum operating voltage is derived from the UL- requirement that it • work down to 80% of its rated (published) minimum operating voltage. 10/22/2010 1 • Voltage Drop Analysis Notification Appliances FCPS -24S8 Notification Appliance Circuit (3.0 amps) Source Voltage: 20.40 VDC Low Line • Protected Premises: PETSMART Date: 10 -22 -10 Address: 7501 S.W. DARTMOUTH City: TIGARD State: OR Zip: 97223 Note: NAC 3 Prepared By: F.E. MORAN, INC. ALARM & MONITORING Phone: 586- 228 -5788 • Address: 33341 KELLY RD. City: FRASER State: MI Zip: 48026 Current Distance (Feet) Circuit Voltage @ Each Device Device # Part Number (amps) Between Total 10 AWG 12 AWG 14 AWG 16 AWG 18 AWG I P2RK110 0.2210 146 146 20.34 20.28 20.23 20.14 19.98 Total Current: 0.2210 % Voltage Drop: 0.32 0.57 0.82 1.30 2.06 Go Go Go Go Go Striketlu:eugh indicates a value below the device's minimum voltage at indicated location and wire gauge. These calculations assume a worst -case source voltage as measured by UL with the batteries depleted to 20.4 volts. Under AC power and for most of the drain cycle of the batteries, the circuit voltages will be substantially higher and thus, would support a greater number of devices. A device's minimum operating voltage is derived from the UL- requirement that it • work down to 80% of its rated (published) minimum operating voltage. 10/22/2010 1 • [Page Too Large for OCR Processing] [Page Too Large for OCR Processing] [Page Too Large for OCR Processing] [Page Too Large for OCR Processing]