Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Specifications
II 2-9'09 5W Cod' 47 A4ECa005 COS I-f Table of contents Carrier. Features /Benefits 1 -3 Model Number Nomenclature 4,5 Options and Accessories 6,7 Physical Data .. ..... ....... ........ .. . 8 . .... .. .... ARI/ISO Capacities 9,10 Dimensions 11 -14 Selection Procedure 15,16 Performance Data 17 -45 Electrical Data 46,47 Typical Piping and Wiring 48 Typical Wiring Schematics 49,50 Application Data 51 -56 Guide Specifications 57 -60 Model number nomenclature • 50RHR,RVR STANDARD EFFICIENCY 50RH R 006 • S C C 3 0 1 3 0 AquazoneTM Water Source Heat Pump T Water 50RH — Horizontal Configuration I 0 —_ None 5ORV — Vertical Configuration Operating Range Efficiency Type 1 — Extended Range with Water Coil R — Standard Efficiency Insulation Package 2 — Extended Range with Water Coil Insulation Package and Sound Size — Nominal Tons Control /Mute Package `006 — 1/2 030 — 2 -1/2 3 — Standard Range without 009 — 3/4 036 — 3 Water Coil Insulation Package ' 012 — 1 042 — 31/2 4 — Standard Range without Water 015 — 1 -1/4 t048 — 4 Coil Insulation Package, but with 019 — 1 -1/2 060 — 5 Sound Control /Mute Package 024 — 2 Packing Airflow Configuration 1 — Single Pack 50RHR Units "50RHR048 -High Static Units Code Return Discharge Code Return Discharge S Left Right D Left Right Revision Code E Left Back F Left Back 0 — Current Revision Z Right Left A Right Left B Right Back C Right Back 5ORVR Units ••50RVR048 -High Static Units V -Ph -Hz Code Return Discharge Code Return Discharge 1 — 575 -3 -60 L Left Top M Left Top 3 — 208/230 -1 -60 R Right Top G Right Top . 4 — 265 -1 -60" 5 — 208/230 -3 -60 • 6 — 460 -3 -60 Controls C — C Control D — D Control Heat Exchanger . H — C Control with high temperature switch C — Copper J — D Control with high temperature switch N — Cupro- Nickel 'Size 006 only available in RHR. tSize 048 also available as high static. "Size 048 high static not available as 265 -1 -60. 4 Dimensions C arrcer 50RHR006 -060 UNITS WATER ELECTRICAL KNOCKOUTS (In.) • OVERALL CONNECTIONS DISCHARGE CONNECTION RETURN CONNECTION SORHR CABINET 1 ' 2 3 G H I Duct Flange Installed (e0.10 In.) Using Return Air Opening UNITS L t/2 conduit 1 /2 conduit 3 /a conduit F Water L M P 0 A e C 0 E Cond• FPT Low Ext Power J K Supply Supply N 0 Return Return R S Width Depth Height In Out ensate Voltage Pump Supply Height Depth Depth Height In. 22 4 43 1 11.3 2.4 5 4 0.6 3.5 5.5 8.2 5.8 4.0 5.8 8.0 5 8 1.5 17.1 9.3 2.2 1.0 006 -012 cm 56.8 109 5 28 7 6.1 13 7 1.5 /2 8.9 14.0 20.8 14.7 10 2 14 7 20.3 14.7 3.8 43.4 23.6 5.6 2.5 015 -024 cm 56.8 109.5 43.9 6.1 12.4 1 5 �/' 8.9 19.1 25.9 12. 14 2 0 .4 P3 6 12. 3.8 `47.4 �5 . 5.6 2.5 030 In. 22.4 53.2 19.3 2.4 5.4 0.6 3/4 5.7 9.7 12.2 5.0 6.8 10.4 9.3 5 0 2.1 23.1 17.3 2.2 1.0 cm 56.8 135.1 49 0 6.1 13.7 1.5 14 5 24.6 31.0 12 7 17.3 26 4 23.6 12.7 5.3 58 7 43.9 5.6 2 5 036 In. 22.4 53.2 19.3 2.4 5.4 0.6 3/a C1:13.) 03 5.7 9.7 12.2 2.9 3.8 . 2.9 1.9 t; ,1> t Z.3) 2.2 1.0 cm 56.8 135.1 49.0 6.1 13.7 1.5 14.5 24 6 31 0 7.4 9.7 34.3 33.3 7.4 4.8 58.7 43.9 5.6 2.5 042-048 In. 22.4 62.2 19.3 2.4 5.4 0.6 1 5.7 9.7 12.2 2.9 3.8 13.5 13.1 2.9 1.9 321 17.3 2.2 1.0 cm 56.8 158.0 49.0 6.1 13.7 1.5 14.5 24.6 31.0 7 4 9.7 34.3 33.3 7.4 4.8 81.5 43.9 5.6 2.5 In. 25.4 71.2 21.3 2.4 5.4 0.6 8.1 11.7 14.2 5.8 5.0 13.6 13.3 5.8 2.9 36 1 19.3 2.2 1.0 060 cm 64.5 180.8 54.1 6.1 13.7 1 5 1 20.6 29.7 36.1 14.7 12.7 34.5 33.8 14 7 7 4 91.7 49 0 5.6 2.5 NOTES: 1. Condensate is 3 /a -in FPT copper. 2. Horizontal unit shipped with filter bracket only This bracket should be removed for return duct connection. 3. Hanger lul is factory installed. Isolation grommets are provided. 4. Right and left orientation is determined by looking at water connection side. LEFT RETURN RIGHT RETURN wamr Wa Conn CAP =Control Access Panel Connection 3 Service 3•srvice CSP CSP= Compressor Service Panel Front AAce= Pe From j BSP =Blower Service Panel ASP =AItemate Service Panel t Left Return Power Supply Right Return il 1 I Me 3 / 4' Knockout 1/ 2' I i CS 3 25 Knockout f •e _ 325 t 6. 10 H 111111 � / Low Voltage G / R 1 / 7 Knockout / , R \ II F CAP D F i / ) / . © Q e E Le ft Discha II' O c \ I Discharge Condensate _ 3 / 4 FPT I - 1 Conde a B Discharge 3 /4" FPT Discharge Front -View I T H Unit Hanger Detail ° - o N MINI ©IISE� T H SP Blower A BSP Blower 3 c Y o I 00 'i ® �� Z C U I Outlet I L L I Outlet a a` It (IF iIF tFi 4 �Ir�Lillrsax41 a N- --r--� 3' 0• `- n 3' SERVICE - I SERVICE ACCESS - AI X i -A-- Awcaa E Configuration - Left Return Beck Discharge B Configuration - Right Return Back Discharge r-1*--I - T K o Blower IT BSP l / M- T ° Left ASP Right Outlet L J BS Blower I CSP a View View Outlet L K I 1 . ,-1- Front - I 3 SERVICE - -Front S Configuration • Left Return Right Discharge - ACCESS F -- - - Z Configuration - Right Return Left Discharge • Air Coil Opening Air Coil Opening Cod S I R r P �Alr Coil 1 . 1 I I _ Air P R I I S I _ o 0 Left C O CSP a ASP V•ieV. I Right - View Front Fronk _ D I I D I S Configuration - Lett Return Right Discharge . Z Configuration - Right Return Left Discharge • Air Coil Opening Air Coil Opening AIRFLOW CONFIGURATION Code Return Discharge S Left Right E Left Back Z Right Left B Right Back - 11 Dimensions (cont) carrier r® 50RHS015 -070 UNITS WATER CONNECTIONS _ KNOCKOUTS (In.) DISCHARGE CONNECTION RETURN CONNECTION OVERALL CABINET 1 2 3 1 G 1 H 3 '1 Duct Flange Installed (1-0.10 In.) Using Air Coil Opening SORBS Loop /2 conduit 1 /2 conduit /4 conduit UNIT F Water L M P 0 A B C D E Cond- FPT Low EXt Pump Power K Supply Supply N 0 Return Return R S Width Depth Height In Out ensate Voltage Supply Height Depth Depth Height 015.018 tn. 22.4 53.2 19.3 2.4 5.4 0.6 3/4 5.7 9 7 12 2 5.0 6 8 10.4 9.3 5.0 2.1 23.1 17.3 2.2 1.0 cm 56.8 135.1 49.0 6.1 13.7 1.5 14.5 24.6 31 0 12.7 17.3 26.4 23.6 12.7 5.3 58.7 43 9 5.6 2.5 024 -030 In. 22.4 62.2 19.3 2.4 5.4 0.6 3/4 5.7 9.7 122 5.0 6 8 10.4 9.3 5.0 2.1 28.1 17.3 2.2 1.0 cm 56.8 158.0 49.0 6.1 13.7 1.5 14.5 24.6 31.0 12.7 17 3 26.4 23.6 127 5.3 71.4 43.9 5.6 2.5 036 In. 22.4 62.2 19.3 2.4 5.4 0.6 3/4 5 7 9.7 12 2 5 0 6.8 10.4 9.3 5.0 2.1 32.1 17.3 2.2 1.0 cm 56.8 158.0 49.0 6.1 13.7 1.5 14.5 24.6 31.0 12.7 17.3 26.4 23.6 12.7 5.3 81.5 4.3.9 5.6 2.5 042 -048 In. 25.4 71.2 21.3 2.4 5 4 0.6 1 8.1 11.7 14.2 5.8 5.0 13.6 13.3 5.8 2.9 36.1 19.3 2.2 1.0 cm 64.5 180.8 54.1 6.1 13.7 1.5 20.6 29.7 36.1 14.7 12 7 34.5 33.8 14.7 7.4 91.7 49.0 5.6 2.5 060 In. 25.4 76.2 21.3 2.4 54 0.6 1 8.1 11.7 142 5.8 5.0 13.6 13.3 58 2.9 41.1 19.3 2.2 1.0 cm 64.5 193.5 54 1 6.1 13.7 1.5 20 6 29.7 36.1 14.7 12.7 34.5 33 8 14.7 7.4 104.4 49.0 5.6 2.5 070 In. 25.4 81.2 21.3 2.4 5.4 0 1 8.1 11.7 14.2 5.8 5.0 13.6 13.3 5.8 2.9 46.1 19.3 2.2 1.0 cm 64.5 206.2 54.1 6.1 13.7 1.5 20.6 29.7 36.1 14.7 12.7 34.5 33.8 14.7 7.4 117.1 49.0 5.6 2.5 NOTES: 1. Condensate is 3 /4 -in. FPT copper 2 Horizontal unit shipped with filter bracket only. This bracket should be removed for return duct connection 3 Hanger kit is factory installed. Isolation grommets are provided. 4. Right and left onentation is determined by looking at water connection side. - LEFT RETURN RIGHT RETURN Water Water Connection Connection CAP =Control Access Panel 3• Service CSP CSP= Compressor Service Panel Front 3 Service A ccess Front j BSP =Blower Service Panel toN. ASP= Alternate Service Panel • /I I Left Return Power Supply Right R4 3 /4" Knockout M oc 1/2' I CSP 3 Knockout L 6 _ 3.25 I. \ I\� . 1 / 2" Knockout n H G I RiII CAP D F 17 c Left Discharge II - 4: charge Condensate Discharge 3/ a' FPT 1--A-----1 Condensa Front -View 3 / 4 FPT Discharge -NH- m Unit Hanger Detail T 9 . BSP h I Model X Y Z I in I- Blower 8SP T Blower ° t Y e 015 -024 43 1 24 375 20375 Z C I Outlet I L -- ' L I Outlet I U 034036 53.1 24375 20.375 U a 042.048 621 24.375 20.375 1 060 71.1 27 375 23 375 a N- 3' _ ,- _ 3 ' SERVICE I SERVICE ACCESS A I X r -A----I ACCESS E Configuration. Left Return Back Discharge B Configuration - Right Return Back Discharge M ,f- T Blower T 1 1- _^^ - ° Right ASP Outlet L BSP / Blower T CSP ° View Left View O ut l et L ■ / K I i ♦ 11 II Front , i SERVICE - Front S Configuration - Left Return Right Discharge - ACCESS F . Z Configuration - Right Return Left Discharge . Air Coil Opening Air Coil Opening Air Coil S IR[ P Air Coil 11 I \ RI j_ S ° T 1 Len C CSP ° C ASP 0 View `i 1 Front Front I B I I D I S Configuration - Left Return Right Discharge • Z Configurason • Right Return Len Discharge . Air Coil Opening Air Coil Opening AIRFLOW CONFIGURATION Code Return Discharge S Left Right E Left Back Z Right Left B Right Back 12 Carrier 5ORVR009 -060 UNITS WATER CONNECTIONS ELECTRICAL KNOCKOUTS (In.) DISCHARGE CONNECTION RETURN CONNECTION OVERALL CABINET G H I 1 2 3 Duct Flange Installed (±0.10 in.) Using Air Coll Opening 5ORVR Loop ' / 2 conduit '/0 conduit 3 /a conduit UNIT F Water L - M P O A B C D E Cond- FPT Low Ext Pump Power K Supply Supply N 0 Return Return R Width Depth Height In Out ensate Voltage Supply Height Depth Depth Height In. 22.4 21 6 22.6 2.6 5 4 7.8 3 5 5.5 8 2 10 6 6 8 5.8 8.0 6 0 2.2 17.1 9.3 1.0 009-012 cm 56.8 54.9 574 6.6 13.7 19.8 /Z 89 140 208 269 173 14.7 20.3 15.2 5.6 434 23.6 2.5 in. 22 4 21.6 34.6 2.4 4.8 8.5 3 3.5 7.5 10.2 7.2 3.8 14.0 14.0 4.3 2.2 17 1 15.3 1.0 015-024 cm 56 8 54.9 87.9 6.1 12.2 21 6 /� 8.9 19.1 25.9 18.3 9.7 35.6 35.6 10.9 5.6 43.4 38 9 2.5 In. 22.4 25.6 40.6 2.4 5.4 9.7 3/ 5.7 9.7 12.2 7 2 5.8 14.0 14.0 4.3 2.2 21.1 19.2 1 0 030 cm 56.8 65.1 103.1 6.1 13.7 24.6 /' 14.5 24.6 31 0 18.3 14 7 35.6 35.6 10.9 5.6 53.6 48.8 2.5 in. 22.4 25.6 40.6 2.4 5.4 9.7 5.7 9.7 12.2 7.2 5 8 14.0 14.0 4.3 2.2 21.1 19.2 1.0 036 cm 56.8 65.1 103.1 6.1 13.7 24.6 /' 14.5 24.6 31.0 18.3 14.7 35.6 35.6 10.9 5.6 53.6 48.8 2.5 In. 22.4 25.6 48.6 2.4 5.4 9.7 5.7 9.7 12.2 7.2 5.8 14 0 14.0 4.3 2.2 21.1 27.2 1.0 042-048 cm 56.8 65.1 123.4 6 1 13.7 24 6 1 14.5 24.6 31.0 18.3 14.7 35.6 35.6 10.9 5.6 53.6 69.1 2.5 In. 25.4 30 6 50.6 2.4 5.4 10.7 8.1 11.7 14 2 6 2 6.3 18.0 18.0 5.1 2.2 26.1 27.2 1.0 060 cm 64 5 77 8 128.5 6.1 13 7 27.2 1 20.6 29.7 36 1 15 7 16 0 45.7 45.7 13.0 5.6 66.3 _ 69.1 2.5 NOTES: 1. Condensate is 3 4-in. FPT and is switchable from side to front 2. Vertical unit shipped with filter bracket only extending from unit 2.5 inches. This bracket should be removed when connecting return duct. 3. Discharge flange field Installed. 4. Right and lett onentation is determined by looking at water connection side. Water Connection Field Installed Access Panels Discharge Flange Standard Fiter Bracket CAP = Control Access Panel CSP =Compressor Service Panel BSP= Blower Service Panel \ / / � ASP=Altemate Service Panel G RIGHT RETURN LEFT RETURN Air Coil B r M K -K M-1 / 1 / r J L I • i0 3' Service L f a 6 Access 13 LL A B Left Return Op CSP 1powe) pnght G /0/ N \ / / o, i Air Coil Side Air Coil Side f t9 R Configuration - Top View -Right Return L Configuration - Top View -Left Return Front `/ 3' Service Isometric P 0 0- P Access View ■ 000 R - i R i i p o � .7 arced / Air Coll O g a a C C 8 8 Condensate Power Supply 3 / 4" FPT 34" HV Knockout 0 Power r for for CAP ill Cannsaw Pump 0 Ile 11 Y de Knockout ASP CSP Low V If I I ® .I 1.2" LV Kf1 0Ck0ul I I I H G � O IF Front Sack Back 2 O Front C oor:El R Configuration - Right Return Right View L Configuration - Left Return Lett View Front View - Air Coil Opening - Air Coil Opening AIRFLOW CONFIGURATION Code Return Discharge L Left Top R Right Top 13 - Typical piping and wiring farrier TYPICAL INSTALLATION — 50RHR,RI-IS UNITS Return Leoo — _ — — 1 3:8' threa e ded rods Supply Loo0 i \ i Water In Filter Access ' - Water Out 1 I (Ductwork Return Air\ • �= not shown) Thermostat Wiring Field- supplied transition to ` I Balancing Valve (field - minimize pressure loss Power Wiring installed and calibrated �� Field- supplied I accesso � 1 — stainless steel cLw Supply A ir ••" ,. braid hose _ : ��* Low Pressure Drop Water ON ���. `c> -is , te,. �' with swivel P -� / Control Valve - . v. �,; 'J" swivel r ; ; - 1 ' (field- installed accessory) " `` ice(" I Unit Power ` Flexible `_`_ I i 1 ` ` � � - 1 �1r Insulated supply duct with Connection � - _ ''`' ? > at least one 90 deg elbow Field - Supplied Unit Power ���� 1� Water Out to reduce air noise Electric Heat Disconnect Water In (field supplied) (if applicable) Unit Hanger Ball Valve with optional Integral P/T plug (typical for supply and return piping) 318' Threaded Rod (by others) 1 Vibration Isolator (white - compressor end and red - blower end) size 042 -070 =_ Washer 44 (by others) -�\ �1. i Double Hex Nuts k\ w (by others) �� Install screw as shown - Sizes 042 -060 Optional on smaller sizes Integral hanger support- pre- attached in factory I UNIT HANGER ISOLATION DETAIL TYPICAL VERTICAL INSTALLATION — 5ORVR,RVS UNITS Supply Air NOTE: Ball valve with inte- L gral pressure temperature `� Building plug recommended. I I : sh- � Flexible Loop Connection �\ 7 Wat Water Out / / In ` , I • Balancing Valve (field - installed and calibrated tai Field - supplied i accessory) i stainless steel I / braid hose Low Pressure with integral I Drop Water "J" swivel / Control valve Power i ( (f installed • I accessory) Thermostat _ Mil . 9 Wrong _ ,/,,,j �/ �� ' Bat Valve with optional T , integral P;T plug Compressor I (typical for supply and Access Panel � `� return piping) 48 Physical data Carrier ® PHYSICAL DATA - AQUAZONETh 50RHR,RVR006 -060 UNITS UNIT 50RHR,RVR 006' I 009 I 012 I 015 019 I 024 I 030 I 036 I 042 I 048 060 COMPRESSOR (1 each) Rotary Reciprocating Scroll FACTORY CHARGE R -22 (oz) 12 15 15 30 30 30 41 44 46 54 80 PSC FAN MOTOR AND BLOWER Fan Motor Type /Speeds PSC /3 PSC /3 PSC /3 PSC /3 PSC /3 PSC /3 PSC /3 PSC /3 PSC /3 PSC /3 PSC /3 Fan Motor (Hp) '/25 1 /10 1 /10 ' /6 '/5 1 /3 1 /2 3 /4 3 /4 3 /4 1 Blower Wheel Size (D x W) 5x5 5x5 6x5 9x7 9x7 9x7 9x7 10x10 10x10 10x10 11x10 WATER CONNECTION SIZE (FPT) 1 /2 1 /2 1 /2 3 /4 3 /4 3 /4 3 /4 3 /4 1 1 1 VERTICAL . Air Coil Dimensions (H x W) (in.) 10 x 16 16 x 16 20 x 20 28 x 20 28 x 25 Total Face Area (ft 1.1 1.8 2.8 3.9 4.9 Tube Size (In.) 3 /6 3 /6 3 /6 3 /6 3 /6 Fin Spacing (FPI) 12 12 12 12 10 • Number of Rows 3 3 3 3 4 Filter Standard — 1-in. Throwaway 10 x 20 16 x 20 20 x 24 28 x 24 28 x 30 Weight (Ibs) 229 257 1 267 323 Packaged 120 I 122 I 131 157 I 179 I 203 231 I 241 269 279 338 HORIZONTAL Air Coil Dimensions (H x W) (in.) 10 x 16 16 x 16 . 18x22 18 x 31 20 x 35 Total Face Area (ft 1.1 1.8 2.8 3 9 4.9 Tube Size (in.) 3 /6 3 /8 3 /3 3 /6 3 /3 Fin Spacing (FPI) 12 12 12 12 10 Number of Rows 2 I 2 ( 3 3 3 3 4 Filter Standard —1 -in. Throwaway 1 —10 x 20 1 — 16 x 20 1 — 18 x 24 2 — 18 x 18 1 - 12 x20 1 — 25 x 20 Weight (Ibs) Operating 110 1 112 I 121 147 I 169 I 193 219 I 229 257 267 323 Packaged I 120 f 122 131 157 179 t 203 231 t 241 269 t 279 338 LEGEND PSC — Permanent Split Capacitor 'Size 006 available in 50RHR unit only. NOTES: 1. All units have spring compressor mountings, TXV (thermostatic expansion valve) expansion devices, and 1 /2- and 3 14 -in. electrical knockouts. 2 Size 048 available as high - static unit. PHYSICAL DATA - 50RHS,RVS015 -070 UNITS UNIT 50RHS,RVS 015 I 018 024 I 030 I 036 I 042 I 048 I 060 I 070 COMPRESSOR (1 each) Rotary Scroll FACTORY CHARGE R -22 (oz) 44 44 48 48 60 74 74 102 104 PSC FAN MOTOR AND BLOWER . Fan Motor Type /Speeds PSC /3 PSC /3 PSC /3 PSC /3 PSC /3 PSC /3 PSC /3 PSC /3 PSC /3 Fan Motor (Hp) 1 /6 1 /6 1 /5 1 /3 1 /2 '/2 3 /4 3 /4 1 Blower Wheel Size (D x W) 9x7 9x7 9x7 9x7 9x7 10x10 10x10 11x10 11x10 WATER CONNECTION SIZE (FPT) 3 /4 3 /4 3 /4 3 /4 3 /4 1 1 1 1 VERTICAL Air Coil Dimensions (H x W) (in.) 20 x 20 24 x 20 28 x 20 28 x 25 32 x 25 36 x 25 Total Face Area (ft 2.8 3.3 3.9 4.9 5.6 6.3 Tube Size (in.) 3 /6 3 /3 3 /6 3 /6 3 /6 3 /6 Fin Spacing (FPI) 12 12 12 10 10 10 Number of Rows 3 3 3 4 4 4 Filter Standard — 1 -in. Throwaway 20 x 24 24 x 24 2 — 14 x 24 2 — 14 x 30 2 — 10 x 30 3 — 12 x 30 1 -12x30 Weight (Ibs) Operating 174 184 250 252 266 323 327 416 443 . Packaged 184 194 260 262 276 333 337 426 453 HORIZONTAL Air Coil Dimensions (H x W) (in.) 18 x 22 18 x 27 18 x 31 20 x 35 20 x 40 20 x 45 Total Face Area (ft 2 8 3.4 3.9 4.9 5.6 6.3 " Tube Size (in.) 3 /6 3 /3 3 /6 3 /6 3 /6 3 /6 Fin Spacing (FPI) 12 12 12 10 10 10 Number of Rows 3 3 3 4 4 4 Filter Standard — 1 -in. Throwaway 18 x 24 2-18 x 18 2-18 x 18 2-12 x 20 1 - 20 x 25 1 — 18 x 20 2 — 24 x 20 _ 1 -24x20 Weight (Ibs) Operating 179 1 189 250 1 252 266 323 327 416 443 Packaged 189 199 260 262 276 333 337 426 453 LEGEND PSC — Permanent Split Capacitor NOTES: 1. All units have spring compressor mountings, TXV (thermostatic expansion valve) expansion devices, and 1 /2- and 3 /4 -in electrical knockouts 2. Size 030 and 036 available as high - static units 8 Olin ARI /ISO capacities Carrier do 50RHR,50RVR WATER LOOP APPLICATIONS EWT LEGEND PRESSURE COP - Coefficient Performance UNIT DROP Cooling 86 F Heating 68 F EER - Energy Efficiency Ratio 50RHR,RVR GPM CFM EER EWT - Entering Water Temperature PSI Ft TC Btuh/W TC COP TC - Total Capacity 006 17 3.9 1.50 180 6,200 12.8 7,400 A.2 NOTES. 009 2.9 6 7 2 25 300 8,100 12.8 10,300 4.3 1. A water -to -air heat pump using water or brine circulating in a common piping 012 8 1 18.7 3.00 375 11,800 12.7 14,600 4.1 loop functioning as a heat source/heat sink. 2. The temperature of the water or brine loop is usually mechanically controlled 015 6 8 15 7 3 75 500 14,100 13.3 16,800 4.6 within a temperature range of 60 F to 90 F. 019 5 6 12.8 4.50 600 18,900 12.5 22,500 3.6 3. Certified in accordance with the ARI /ISO Standard 13256 -1 Certification 024 5 8 13.5 6.00 800 23,000 12.3 27,600 4.2 Program, which replaces ARI Standard -320. 4. Size 006 available as RHR model only. 030 3.3 7.6 7.50 1000 28,500 13.2 33,300 4.4 036 2.9 6.8 9.00 1200 34,000 13.0 41,700 4.2 042 3 8 8 8 10.50 1400 40,000 13.0 46,700 4.3 048 5.4 12.4 12.00 1600 47,000 12.8 58,000 4.2 . 060 7.9 18.2 15 00 2000 59,000 12.8 68,000 4.2 50RHR,50RVR GROUND LOOP APPLICATIONS LEGEND PRESSURE EWT COP - Coefficient Performance UNIT DROP Cooling 77 F Heating 32 F EER - Energy Efficiency Ratio 50RHR,RVR GPM CFM PSI Ft TC EER TC COP EWT - Entering Water Temperature Btuh/W TC - Total Capacity 006 1.7 3.9 1.50 180 5,600 14.3 4,400 3.4 NOTES: 009 2.9 6.7 2.25 300 8,300 14.2 6,200 3.4 1. A brine -to -air heat pump using a brine solution circulating through a subsur- 012 8.1 18.7 3.00 375 12,100 1 14.2 8,700 3.4 face piping loop tunctiomna as a heat source/heat sink. 015 6.8 15.7 3.75 500 14,500 14.8 10,700 3.5 2. The heat exchange loop may be placed in horizontal trenches or vertical bores, or be submerged in a body of surface water. 019 5.6 12.8 4.50 600 19,100 13.4 11,800 3.2 3. The temperature of the brine is related to the climatic conditions and may 024 5 8 13.5 6.00 800 23,000 13.3 16,700 3.3 vary from 20 F to 110 F. 4. Certified in accordance with the ARI /ISO Standard 13256 -1 Certification 030 3.3 7.6 7 50 1000 28,700 14.4 20,100 3.4 Program, which replaces ARI Standard -330. 036 2.9 6.8 9.00 1200 35,200 14.7 25,500 3.4 5. Size 006 available as RHR only. 042 3 8 8.8 10.50 1400 42,000 15.0 29,400 3.4 048 5.4 12.4 12.00 1600 48,500 14.3 35.300 3.3 060 7.9 18.2 15.00 2000 60,600 14.1 44,000 3.2 50RHR,50RVR GROUND WATER APPLICATIONS LEGEND PRESSURE EWT COP - Coefficient Performance UNIT DROP Cooling 59 F Heating 50 F EER - Energy Efficiency Ratio 50RHR,RVR GPM CFM EER EWT -- Entering Water Temperature • PSI Ft TC Btutt/W TC COP TC - Total Capacity 006 1.7 3.9 1.50 180 5.900 17.6 5,500 3.8 NOTES: 009 2.9 6.7 2.25 300 8,800 176 7.700 3.8 1. A water -to -air heat pump using water pumped from a well, lake or stream 012 8.1 18.7 3.00 375 12,500 17.6 1,100 3.8 functioning as a heat source/heat sink. 015 6.8 15.7 3.75 500 15,200 17.6 13,500 4.1 2. The temperature of the water is related to the climatic conditions and may vary from 40 F to 80 F 019 5.6 12.8 4.50 600 20,100 17 6 16,700 3.4 3. Certified in accordance with the ARI /ISO Standard 13256 -1 Certification 024 5.8 13.5 6.00 800 26,100 18 2 21,300 3.7 Program, which replaces ARI Standard -325. 4. Size 006 available as RHR only. 030 3.3 7.6 7.50 1000 31,100 18 6 27,000 3.9 036 2.9 6.8 9.00 1200 37,500 18.2 33,400 3.9 042 3.8 8.8 10.50 1400 48,500 18.6 38,300 3.9 048 5 4 12.4 12 00 1600 54,000 181 46,000 3.8 060 7.9 18.2 15.00 2000 64,500 16.8 56,000 3.8 ARI /ISO capacity notes e 1. Cooling capacities based upon 80.6 F DB (dry bulb), 66.2 F WB (wet bulb) entering -air temperature. 2. Heating capacities based upon 68 F DB, 59 F WB entering -air temperature. 3. All ratings based upon 208 volt operation. 61 4s. VA 1 % S ,,....` 4 r 9 ')114 Electrical data Car 50RHR,RVR ELECTRICAL DATA 50RHR,RVR VOLTS -PHASE VOLTAGE COMPRESSOR FAN TOTAL MIN MAX UNIT 60 Hz MIN /MAX RLA LRA MOTOR UNIT CIRCUIT FLA FLA AMP FUSE/HACR 006" 208/230 -1 197/254 2.9 17.7 0.40 3.3 4 0 15 265 -1 239/292 2.5 15.0 0.35 2.8 3 5 15 009 208/230 -1 197/254 3.9 22 2 0.80 4 7 5.7 15 265 -1 239/292 3.3 18.8 0.90 4.2 5 0 15 012 208/230 -1 197/254 5.3 27.9 0.80 6.1 7.5 15 265 -1 239/292 4.2 22.2 0.90 5.1 6.2 15 015 208/230 -1 197/254 5.9 29.0 1.00 6.9 8.4 15 265 -1 239/292 5.4 27.0 0.86 6.3 7.7 15 019 208/230 -1 197/254 7.9 48.3 1.10 9.0 11.0 15 ' 265-1 239/292 7.1 41.0 0.90 8.0 9.7 15 208/230 -1 197/254 8.7 48.3 1.30 10.0 12.1 20 i 024 265 -1 239/292 8.3 47.0 1.58 9.9 12.0 20 208/230 -3 197/254 6.0 50.0 1.30 7.3 8.8 15 460 -3 414/506 3.2 25.0 0.85 4.1 4.9 15 208/230 -1 197/254 11.2 60.0 1.90 13.1 15.9 25 030 265 -1 239/292 10 3 58.0 1.66 11.9 14.5 20 208/230 -3 197/254 6.4 50.0 1.90 8.3 9.9 15 460 -3 414/506 3.2 25.0 1.00 4.2 5.0 15 208/230 -1 197/254 14.1 84.0 3.00 17.1 20.6 30 036 265 -1 239/292 13.5 83.0 2.70 16 2 19 5 30 208/230 -3 197/254 8.2 63.4 3.00 11.2 13.3 20 460 -3 414/506 4.1 36.0 1.70 5.8 6.8 15 208/230 -1 197/254 16.2 96.0 3.00 19.2 23.2 35 042 208/230 -3 197/254 10.3 75.0 3.00 13.3 15.8 25 460 -3 414/506 4.3 40.0 1.70 6.0 7.1 15 575 -3 518/633 3.7 31.0 1.50 5.2 6.1 15 208/230 -1 197/254 18.3 102.0 3.40 21.7 26.2 40 048 208/230 -3 197/254 12.6 91.0 3.40 16.0 19.2 30 460 -3 414/506 5.7 42.0 1.80 7.5 8.9 15 575 -3 518/633 4.7 39.0 1.60 6.3 7.5 15 • 208/230 -1 197/254 25.6 170.0 4.30 29.9 36.4 60 060 208/230 -3 197/254 14.7 124.0 4.30 19.0 22.7 35 460 -3 414/506 7.4 59.6 2.50 9.9 11.8 15 • 575 -3 518/633 5.9 49.4 2.20 8.1 9.8 15 LEGEND FLA - Full Load Amps HACR - Heating, Air Conditioning and Refrigeration LRA - Locked Rotor Amps RLA - Rated Load Amps 'Size 006 is available in 50RHR units only 30 i