Correspondence
City of Tigard, Oregon • . 13125 SW Hall Blvd. • Tigard, OR 97223 April 15, 2009 n RE: FIRE ALARM SYSTEM T I CARD Project Information Building Permit: FPS2009 -00013 Construction Type: NA Tenant Name: Allstate Occupancy Type: B Address: 7632 SW Durham Rd. Required: Yes The plan review was performed under the State of Oregon Structural Specialty Code (OSSC), 2007 edition the Oregon Fire Code 2007 edition and 2002 edition of NFPA 72. The submitted plans are approved subject to the following. General Requirements A separate low- voltage electrical permit is required for installation and inspection of alarm wiring. A completed inspection and testing form is required at the time of final inspection containing the information as outlined in NFPA section 10.6.2.3. TESTING — NFPA 72 Chapter 10, OFC 901.2.1, 901.5, 903.5 1. Upon completion of the installation, a satisfactory test of the entire system shall be made in the presence of the building inspector. All functions of the system or alteration shall be tested. 2. A record of completion in accordance with NFPD 72 verifying that the system has been installed in accordance with the approved plans and specifications shall be provided. VISUAL ALARMS — NFPA 72 - 5.14.5, 7.5.4, OSSC chapter 9 & 11 3. When required; Visual alarms shall be located not less than 80 inches and not more than 96 inches above floor level. When a low ceiling exists, the visual alarm shall be mounted within the dimensions stated above and at least 6 inches below the ceiling. No place in a room shall be more than 50 feet from a visual signal. In corridors spacing between devices shall be no more than 100 Ft. and no more than 15 Ft. from the end. MANUAL ALARM - 1109.2.3.5, 1109.2.3.6 OSSC 4. Manual Fire Alarm activation devices when installed shall be mounted in the following reach ranges: • Forward Reach -15 inches to 48 inches above the floor. • Side Reach — 9 inches to 54 inches above the floor. Phone: 503.639.4171 • Fax: 503.684.7297 • www.tigard- or.gov • TTY Relay: 503.684.2772 ALARM SIGNALS — OFC 903.4 5. Alarm, supervisory and trouble signals shall be distinctly different and shall be automatically transmitted to an approved central station, remote supervising station or proprietary supervising station as defined in NFPA 72 or, when approved by the fire code official, shall sound an audible signal at a constantly attended location. 6. Duct smoke detectors shall be connected to the building's fire alarm control panel when a fire alarm system is provided. Activation of a duct smoke detector shall initiate a visible and audible supervisory signal at a constantly attended location. Duct smoke detectors shall not be used as a substitute for required open -area detection. 7. Automatic fire- extinguishing systems shall be connected to the building fire alarm system where a fire alarm system is required by another section of this code or is otherwise installed. OSSC 907.13 Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.3.1 OSSC Premises Identification: Approved numbers or addresses shall be provided for all new buildings in such a position as to be plainly visible and legible from the street or road fronting the property. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. . Respectfully, r tOrr—j2k) Dan Nelson, Senior Plans Examiner (503) 718 -2436 dann @ tgard - or.gov rP52ozn 4 - cco I3 Capitol ?� 325w�� L. c Electric Co., Inc. April 8, 2009 RECEIVED APR 13 2009 • CTfY�G DIVISION O BUILD N Plans Examiner • City of Tigard Building Services 13125 SW Hall Blvd. Tigard, OR 97223 Re: Allstate Tenant Fire Alarm System Additions Southwest Center Office Building, 2 Floor 7632 SW Durham Road Tigard, OR 97223 Please find attached building and electrical permit applications, Tri- County Commercial Application Checklist, two sets of plans, calculations, and product submittals for the fire alarm tenant improvements at the address shown above. Occupancy Group: B The fire alarm system design includes the following 1. Update tenant improvement areas shown on fire alarm plans to include new and relocated fire alarm evacuation devices. 2. We will pre -test the fire alarm devices prior to requesting a final fire alarm inspection. Please contact me if you have questions or comments. Respectfully, 105.v 84 Dan Wilson ' S q , g Project Manager/Estimator Fire/Life Safety Division Capitol Electric Company, Inc. (503) 255 -9488 . dan @cepdx.com NICET Level IV, Fire Alarm Systems #104512 11401 NE Marx • Portland, Oregon 97220 -1041 • 503 - 255 -9488 • Fax 503 - 257 -7121 • CCB# 48748 • www.capitolelectricco.com FP52o6'9 —o 9f3 TRI- COUNTY COMMERCIAL APPLICATION CHECKLIST RECEIVED Date: 4/7/2009 APR 13 ?009 Project Name: ALLSTATE T.I. CITY OF TIGARD _WILDING DIVISION Project Address: 7632 SW DURHAM ROAD TIGARD, OR 9223 Scope of Work: INSTALL FIRE ALARM NOTIFICATION DEVICES FOR TENANT FLOOR PLAN CHANGES Reference # : Map & Tax Lot # : • Contact Person: Name: Dan Wilson Phone: (503) 255 -9488 Cellular: (971) 506 -3072 Fax: (503) 255 -1966 E -mail: dan @cepdx.com Company: Capitol Electric Company, Inc. Please Note: • The purpose of this checklist is to help define a complete submittal package for the scope of work. Plan review will not take place until a complete package is submitted. • This checklist can be used for all commercial construction projects, including new construction, additions, alterations, and tenant improvements (Tls). • For complex projects, applicants should use the "location" space to note the item's location and page number from the plans or the specification book. • It is not necessary to duplicate submittal information, even if it is asked for in multiple sections. • REQUIRED means that the applicant must provide this information for plan review. • ❑ P means (a) if checked by the applicant, the information is provided for the plan review or (b) if checked by the plans reviewer, this information is required for the plan review. • p NA means that the information does not apply. ■ Choose only those sections of the checklist that apply to your scope of work. Section 1.0, "General Project Data ", must be included with each project submitted. 1 Commercial Checklist For Tri- County Building Department Jurisdictions in Clackamas, Multnomah, and Washington Counties ▪ Section 1.0 General Project Data Construction Documents ▪ No: Item: Location (sheet number or spec section): 1.1 © REQUIRED (Number) 2 Sets Of Plans 2 SETS PROVIDED 1.2 © REQUIRED Cover sheet title block (On Plans) 1.3 © REQUIRED Cover sheet vicinity map (mapquest.com) ATTACHED 1.4 El REQUIRED Cover sheet index ( REQUIRED IF LARGE NUMBER OF PAGES ) 1.5 © P ❑ NA Code summary Cover Letter 1.6 ❑ P © NA Deferred submittal summary 1.7 ❑ P © NA Professional stamp and signature (For new bldg, meets intent of architect design) 1.8 J P © NA Fire and life safety plan 1.9 ❑ P © NA Landscape plan 1.10 ❑ P © NA Landscape specifications Supporting Documents No: Item: Notes: 1.20 ❑ P © NA Land use or planning actions 1.21 El P © NA Required fire flow calculations 1.22 ❑ P © NA Fire hydrant flow test report 1.23 ❑ P © NA Fire department or fire district building survey report 1.24 ❑ P © NA Landscape specifications • • 3 Commercial Checklist For Tri- County Building Department Jurisdictions in Clackamas, Multnomah, and Washington Counties Section 11.0 Fire Detection and Alarm Data Construction Documents No: Item: Location (sheet number or spec section): 11.1 13 REQUIRED Floor plan(s) FP1 11.2 El P 13 NA Site plan 11.3 ❑ P © NA Reflected ceiling plan(s) 11.4 0 P 13 NA Transverse & longitudinal cross section(s) 11.5 n P 13 NA Wiring schematic 11.6 0 P 13 NA Elevator recall information 11.7 U P © NA Operational matrix 11.8 0 P © NA Fire -rated construction details 11.9 El P 13 NA Standard electrical notes Supporting Documents No: Item: Notes: ' 11.20 REQUIRED Structural calculations for vertical loads and lateral loads for equipment weighing over 400 lbs. No loads over 400 lbs 11.21 © REQUIRED Equip. manufacturer's catalog "cut sheets" Included 11.22 © REQUIRED Installer certification information Included 11.23 13 P 0 NA Battery calculations Included 11.24 p P 13 NA Sample fire alarm log book 11.25 0 P © NA Emergency power system specifications 11.26 P © NA Monitoring station information 11.27 13 P El NA Voltage drop calculations Included 14 Commercial Checklist For Tri- County Building Department Jurisdictions in Clackamas, Multnomah, and Washington Counties FIRE ALARM INSTALLER CERTIFICATION INFORMATION A Date: 4/7/2009 Project Name: ALLSTATE T.I. Project Address: 7632 SW DURHAM ROAD TIGARD, OR 97223 Scope of Work: INSTALL FIRE ALARM NOTIFICATION DEVICES FOR TENANT FLOOR PLAN CHANGES Reference # : 0 Map & Tax Lot # : 0 Contact Person: Name: Dan Wilson Phone: (503) 255 -9488 Cellular: (971) 506 -3072 Fax: (503) 255 -1966 E -mail: dan @cepdx.com Oregon License: 17231J • NICET Cert.# 104512 Fire Alarm Systems, Level IV Company: Capitol Electric Company, Inc. 11401 NE Marx Street Portland, Oregon 97220 (503) 255 -9488 Office (503) 255 -1966 Fax Oregon License: 26 -496C Commercial Checklist For Tri- County Building Department Jurisdictions in Clackamas, Multnomah, and Washington Counties