Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Correspondence
City of Tigard, Oregon • 13125 SW Hall Blvd. • Tigard, OR 97223 August 12, 2008 RE: RACK STORAGE T I GARD Building Permit: BUP2008 -00261 Construction Type: 3B Tenant Name: Consumer Cellular Occupancy Type: B Address: 16260 SW Upper Boones Ferry Occupant Load: 54 The plan review was performed under the State of Oregon Structural Specialty Code (OSSC) 2007 edition; and the Oregon Fire Code (OFC) 2007 Edition. Please provide the following prior to issuance. Fire Extinguishers: Provide 2 -A rated fire extinguishers as required per table 906.3 (1) of OFC the extinguisher shall be located so that no usable space has a distance greater than 75 feet to the extinguishers. OFC 906.3 Clearance: The clearance between the sprinkler deflector and the top of storage shall be 18 in. or greater. NFPA 13 8.5.6.1 Loads Posted: The racks shall display in one or more conspicuous locations a • permanent plaque not less than 50 square inches in area, showing the maximum permissible unit load in clear legible print. OSSC 1603 . • Approved Plans: 1 set of approved plans, bearing the City of Tigard approval stamp, shall be maintained on the jobsite. The plans shall be available to the Building Division inspectors throughout all phases of construction. 106.4.2 OSSC When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard, Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectf , 1i , an Nelson, • Senior Plans Examiner (503)718 -2436 dann a©tigard -or.gov • Phone: 503.639.4171 • Fax: 503.684.7297 . • www.tigard- or.gov • TTY Relay: 503.684.2772 Ina 7373 S.E. Milwaukie Expressway Imer Portland, Oregon 97222 ���068 = � J D &' / P.O. Box 68348 • Portland, Oregon 97268 OF OREGON, INC. (503) 659 -5438 • FAX (503) 653 -6966 2 6 4 5141 el % � ,� J ,� F� wow 1- 800 - 452 -0050 Material Handling Specialists w /'- www.norliftor.com - City of Tigard 13125 SW Hall Blvd RE Tigard OR 97223 JUL 2 a 2008 Dan Nelson G I y OF TIGARD In regards to Consumer Cellular at 16260 SW Upper Boones Ferry Rd Buil aIISION Tigard OR 97224 They will be storing cell phones class IV The sprinkler system is .30GPM / 2000 SQFT Hydraulic system The heads are at 286 degrees There are single rows and double rows but no multiple rows The maximum storage height on the racks will be 13' 4" The distance between the top of the commodity and the sprinkler deflector is approximately 24" or greater The sprinkler heads are at approximately 15' 6' Total area of rack high pile storage is 2400 SQ FT and non public accessible The aisles between the racks are 8' or greater Transverse flues are provided at rack uprights and between pallet loads. Currently no curtain boards not required There high pile storage racks will have no solid decking Required sprinkler density per NFPA 13 required for class IV with storage to 14' Non encapsulated with aisles 8' or greater Table 12.3.2.1.2 D curve E with 286 degree heads Requires .50 GPM / 2000 SQFT . Apply 12.3.2.1.5.1 at 14' .50 X .60 = .30 .50 X .60 = .30 Gallons per minute over 2000 square feet required • Thanks my cell number is 503 -519 -3043 Brian Ferrick y czytek Fn L IFT o . os r anr 1I UNGHE!/ fmcff ((Kalmar; PRINCETON CUIRK jiff