Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
[Page Too Large for OCR Processing] [Page Too Large for OCR Processing] [Page Too Large for OCR Processing] [Page Too Large for OCR Processing] [Page Too Large for OCR Processing] FP5 20 !a- 00t 3 1333 , 6)g Pkwy RECEIVED / SEP302010 CITY OF TIGARD BUILDING DIVISION Your Premier Partner For Low Voltage Systems / - tI14!�%4- ff-5OUWffD 5YSTOM.S LLC ACS - 2 " Fl. LAN Room 13333 SW 66 Parkway Tigard, OR. 97223 FM -200 Fire Suppression System #608S Equipment Datasheets Battery and Voltage Calculations Prepared by: E- Squared Systems, LLC PO Box 731227 Puyallup, WA 98373 Ph: 253.284.3707 Fax: 253.284.3714 License: ESQUASL963BR Submittal Index Project Type of Equipment ACS FM -200 Suppression 2 Floor LAN Room Job #608S 1 3333 SW 66 Parkway Tigard, OR. 97223 Customer Supplier Patriot Fire Protection E- Squared Systems, LLC 4708 NE Minnehaha St. PO Box 731227 Vancouver, WA 97223 Puyallup, WA 98373 License: ESOUASL963BR Fire Alarm System Datasheets Manufacturer Part No. Description Fike 10-063-1-R1 Suppression Control Panel Fike 10 -2204 Relay Module Fike 10 -2748 Impulse Release Module Fike 63 -1024 Photoelectric Smoke Detector Fike 67 -1034 Detector Base Fike 10 -1638 Manual Release Station Fike FM -200 Suppression agent Fike 70-279 Impulse Valve Operator Kit Fike 70-267 150# FM -200 Cylinder Fike — Impulse Valve Fike 80- 0XX -XXXX Discharge Nozzles Fike 02 -101XX Warning Signs SAE IAVHORN Horn Module SAE IAVSLM24 -B Incandescent Light Module SAE IGP -XX Mounting Plates SAE IGB -XX Back Boxes System Sensor R -20E Auxiliary Relay Werker WKA 12 -7.5F Battery Battery & Flow Calculations Panel Calculation Description SCP Battery Suppression Control Panel Cylinder Flow Piping • ® 0 00 _ _ SHP PRO DESCRIPTION The Fike SHP PROD, (P /N 10 -063) is a Conventional Control system designed to -- provide a sophisticated, reliable conventional detection system for use with clean _ agent extinguishing, sprinkler pre -acuon /deluge, watermist, waterflow alarm and fire alarm systems. It is a microprocessor based system which can be easily configured for a wide range of suppression applications. The SHP PRO is designed for use with Fike Clean Agent Fire Suppressant, CO2, or sprinkler (pre- action /deluge) suppression systems. The main controller contains all electronics required for a complete detection and control system suitable for most applications. Optional modules, which plug into the main circuit board, are available -- to add increased functionality to the system. The SHP PRO provides 10 Status LEDs (AC Normal, .• llarm , PreDischarge, Release, Supervisory, Trouble, Panel Silenced, Abort, Release Disabled, Ground Fault) for instant feedback. A diagnostic LED display is provided to help trouble shoot any potential field problems, provide current status and retain stored events. APPROVALS A Reset and Silence switch is provided to allow control of the system outputs and • UL S2203 operation. • FM 3017159 • CSFM 1765 -0900: 135 The SHP PRO can be configured for either one or two conventional detection MEA 461 -04 -E • circuits. The detection circuits can be configured for sequential detection, cross zone or single detector release. Depending on the configuration selected, the SHP PRO also provides up to three initiating circuits to monitor contact devices (Abort, Manual Release, Waterflow or Supervisory switches). Four different abort types are available including a special NYC option. All five initiating circuits can be converted to Class A operation via the SHP PRO Class A Input Module, P/N 10 -2450. All SHP PRO initiating circuits are inherently power limited. A twelve position dip switch is used to set all options. Three notification appliance circuits, rated for 2 amps @ 24 VDC are available. Depending on the configuration, each circuit will provide distinct signaling for Alarm, PreDischarge, or Release conditions. Separate Agent Release and Solenoid circuits arc provided to operate the suppression system. A dedicated Disable switch is provided for release and audible outputs. All output circuits, including solenoid and agent release circuits, are power limited. The SHP PRO provides dedicated alarm, trouble and supervisory SPDT contacts for annunciation and control. If additional outputs are required, up to two CRM4 Relay Modules can be added. (P /N 10- 2204) The SHP PRO is available in multiple hardware configurations, depending on the input power source (120 or 240 VAC), enclosure color (Gray or Red), and mode of operation (Clean Agent, Clean Agent /Sprinkler, Sprinkler, Watermist, Solenoid Releasing). The system comes equipped with a 4.0 amp @ 24 VDC power source. The system has been designed to comply with the following standards: • NFPA 12 Carbon Dioxide • NFPA 12.1 Halon 1301 Extinguishing Systems • NFPA 13 Installation of Sprinkler Systems • NFPA 15 Water Spray Fixed Systems • NFPA 16 Deluge, Foam -water and Foam -spray Systems • NFPA 70 National Electric Code • NFPA 72 Installation, Maintenance and Use of Protective Signaling Systems • NFPA 2001 Clean Agent Fire Extinguishing Systems Form No. D.1.07.01 -6 704 S 10th Street P.O. Box 610 • Blue Springs, Missouri 64013 -0610 U.S.A. (816) 229 -3405 • (816) 229 -4615 • www fike corn • FEATURES • Suitable for multiple types of Suppression: Clean Agent, Carbon Dioxide, Pre - Action Sprinkler /Deluge, and • Watermist Systems • Microprocessor based with hardware and software integration designed to guarantee reliability • Cross zone, sequential manual release, abort, water flow and supervisory detection types • Three Class B, Style Y notification appliance circuits rated for 2.0 amps @ 24VDC • Dedicated release circuits compatible with agent release or solenoid actuation • Five Class B, Style B initiating circuits • Optional Class A modules for notification appliances /releasing circuits and initiating circuits • Alpha - numeric LED display for status and troubleshooting • Programmable pre - discharge and discharge timers • Resettable and continuous auxiliary output power • Integral 4.0 amp power supply • Small surface or flush mount enclosure with removable door • Approved for releasing device service and sprinkler supervisory • Built-in Gentex and System Sensor synch protocol • Steel enclosure 21" x 14.35" x 4" • Enclosure equipped with .50" wide lip for flush mounting SHP PROT"' WIRING DIAGRAM COMPONENTS • I 0-063-X-X-X - ' — • 10- 063 -X -Z -Z ABC ��� A: 1 -Clean Agent /All Modes 2- Sprinkler only — B: R -Red alipE ......... G -Gray Ea C: 1- 120 VAC 2 -240 VAC 1 =O■M■\ © u - - 0, ssl. s0030Os © ' _ _ �„.,,,,, • 10 -_45_ 2_ 1 PCB Ass}, SHP PRO, _ I .- • D z, 1 f : A 4 1 Clean Agent, All Modes ' la I -- r..—...1.17. _ i o • 10- 2452 -2 PCB Assy, SHP PRO, ®, °. I z i j _ � Sprinkler Only ® _ o e� " -e p . �° s . iH s i i� ` :: • 10 -2450 Class A Input Module m a o o ® i - 1l I I --A2,0 • 10 -2448 Class A Output Module �_ a li tit; o :� , ® tl - • 10 -2204 CRM4 Relay Module i . E • 10- 2190 -1 Battery Assembly r J , "" 1 (Qty 2), 7AH, w/ wiring assembly I 190 -2 Battery Assembly © ` o et OQ 0002 L _ © 51=1 10- 2 c e _ o (Qty. 2), 18AH, w/ wiring � 2 - assembly 0 le. 10 , -.T.....) i 0..._. O o I1i' lo �..,._ FIke Copyright © Fike Corporation All Rights Reserved. Form No. D.1.07.01 -6 May, 2009 Specifications are subject to change without notice. An ISO 9001 -2000 Company Ftke 10 -2204 Relay Module (CRM4) Installation Instructions ® 0 0 0 DESCRIPTION • The 10 -2204, CRM4 Relay Module provides four (4) 10- 000000 w 1 . individual single pole, double throw (SPDT) relay P41 c r a c tic ma c K. " rro TK7 N° ' contacts. Each relay is individually configurable to 'tt I 72 - RZAT3 "' K± transfer upon activation of the associated _ z _ ++ � � zone /state. The module mounts directly to the L � r I ' ^ —_ ( x.t � associated control panel circuit board using the o_� following mounting i hardware provided with the rz+ "0 c3 c`® `s - module: Standoff Hardware Kit, P/N 02 -12031 Exhibit 1: CRM4 Relay Module 02 -3794 Standoff, 1.25" F /F, 6x32 hex (qty. 4) PROGRAMMING 02 -1589 Screw, 6 -32 x 0 375 Phillips (qty. 8) Each CRM4 relay output can be individually COMPATIBILITY configured for any zone and state output on the Cheetah, Cheetah Xi, and CyberCat control system. The CRM4 is compatible with the following Fike Use the respective configuration software to control panels: Cheetah, Cheetah Xi and SHP -Pro program the desired operation. Fire Alarm and Suppression panels, and the CyberCat 254 and 1016 Fire Alarm panels. The SHP -Pro will operate with specific states as per the dip switch settings as noted in the SHP -Pro SPECIFICATIONS manual, no other programming is allowed. Current Consumption: 11 mA normal standby OPERATIONS 39mA alarm (all relays active) The CRM4 provides a versatile option to connect Contact Ratings: SPDT Form C relay contact equipment interfaces directly located at the Fire C = Common Control Panel. The addressable systems provide NO = Normally Open full programmability of the relay contacts for any NC = Normally Closed zone and state in the fire system. The SHP -Pro DC rating: 2A @ 30VDC provides relay activation per the dip switch selection AC rating: 0.5A@ 120VAC required for the installation. Common functions Note: May be connected to power - limited or non consist of HVAC system shutdowns, door closures, power - limited sources. All connections to terminal fans, and communication to building interfaces. block shall be either power - limited or non power - limited, not both. MODULE MOUNTING LOCATIONS Dimensions (LxWxD): 3.5" x 1.5" x 2" The acceptable mounting location(s) for the CRM4 (8.9cm x 3.8cm x 5.08cm) relay module vanes depending upon the control Weight: 0.10 lbs. (45 grams) panel that it is to be connected to. Exhibits 2, 3 and Operating Temp: 32 °F to 120 °F (0 °C to 49 °C) 4 show the acceptable module mounting locations Operating Humidity: 93% RH, non - condensing for each control panel for reference purposes. LISTINGS AND APPROVALS UL S3217 FM 3023436 CSFM 7165 - 0900:137 CyberCat Non High -Rise 7170 - 0900:148 CyberCat High -Rise 7165- 0900:149 Cheetah Xi Non High -Rise 7165 - 0900:135 SHP -Pro MEA 461 -04 -E SHP -Pro 490 -04 -E CyberCat 307 -05 -E Cheetah Xi City of Denver Fike 704 SW 10 Street, P.O. Box 610, Blue Springs, Missouri 64013 -0610 U.S.A. • Tel: (816) 229 -3405 • Fax: (816) 229 -4615 Mule every precaution has been taken dunng the preparation of this document to ensure the accuracy of its content, Fike assumes no responsibility for errors or omissions Fike reserves the nght to make changes to the product or this document without notice www.flke.com P/N 06 -345 Rev. 2 page 1 of 2 CRMP/N RELAY MODULE CRMPM 0-204 MODULE _ INSTALLATION INSTRUCTIONS 0 Feeoeeeee 0 0 [0000000053000;1 O `[ 3 � i 8 n -- ii.T.ri:2z715.5°1 •= a. - - - 1. If the system is already powered, disable critical _ . 'N functions and power down system. ®- " 0 CAUTION • b di ro o .• The CRM4 circuit board contains static sensitive ;' , . components. Handle the electronics by the edges • — only and avoid touching the integrated components. :: Keep the electronics in the protective static bag it ° -' •' was shipped in until time for installation. Always � e • • —P no %_ ,. �. ground yourself with a proper wrist strap before `:?' 9 Q® handling the module(s). If the installer is properly Ie ; , �.. �; I I grounded at all times, damage due to static • nu BAT �•� I I ® discharge will not occur. If the module requires ® - LJ ®1I 1 ., repair or return to Fike, it must be shipped in an anti - Ill ® o ��' M. + -I o ® Flaa..°a «, static bag. Exhibit 2: CRM4 to Cheetah Installation (P41/P42) 2. If the main controller is already installed in the back -box, remove it by disconnecting the field removable terminal blocks and removing the e ° °eee °e° a °eB° >00000000, �° four hex nut/lock washers located in each corner 0 w1.l [ 41 Ii H _ 0 of the board (qty. 4). 0 0 0 eeeeeeeeeoeo O (iD • 73 2: J E ' cal1410,11,1M . 3. Secure the F/F standoffs (qty. 4) to the main o 0 a � ° IN 10-2204 I 'rM `F o t board by threading the four 6x32 screws through PIN m NIag :m gd: 0 0 0 0 the back of the main board into the standoffs. fiitrli 1 t Make sure that the screws are not making y a 1 i contact with any of the electronic components 0 ' o o © on the circuit board. I� 4. Re- install the main board by aligning the four mounting holes with the standoffs in the p enclosure back -box. Secure in place with the 1 I � four #6 hex nuts and lock washers. o a 1 .® °, 5. Carefully unpack the module and check for O 1 = =:-n .. shipping damage. lma0a 6. Insert the CRM4 module into the respective Exhibit 3: CRM4 to CyberCat and header provided on the main board making sure Cheetah Xi Installation (P12/P13) that header pins are properly aligned. Secure the module to the F/F standoffs using the four 6/32 screws (qty. 4). © O C ® ® ® ®1 ® ® ® ®1 ®1 ® ® ®® © 7. Prior to connecting field wiring, power up the - g o " '�" " " o = _ ® controller. Once each board has been � � f _,_ 1 : ; �, ® successfully powered, power down and connect ± F WV: IO --• �`° . „ „ - , ® field wiring. ® i 4a 8K m.0 1 .m., 1 3 L I- T LCAUTION ®ya-I o Y O. 0 9 �.Q o t..14.' r — — — - C } a �, V , m „ • • ® During the first few seconds of power -up, the ® - ; o C 0KUM =vnEo ®�, ' ® associated control panel may not have full control of ® ° 9 gy” K, ,�,=.Eo ®SI • ® the CRM4 rela contacts and they ma momentarily ' ® ° 8 0 o� r.•, 0 •m' I T} ® chatter. If using the relays for critical functions, �a � ® control t output closed or open respectively during rya: "��'°” •' 11G14i ' G ' i ® controller power -up and power -down. g .® } ® 8. Power back up and complete installation O o LOJ t o . ® ® ® ®o L - - - -QJ C° " procedures for the system. Exhibit 4: CRM4 to SHP -Pro Installation (P8/P9) Fike 704 SW 10 Street, P.O Box 610, Blue Springs, Missouri 64013 -0610 U.S.A • Tel: (816) 229 -3405 • Fax: (816) 229 -4615 P/N 06-345 Rev. 2 page 2 of 2 www.fike.com Ike 0 IMPULSE RELEASE MODULE DESCRIPTION The Impulse Releasing Module (P /N 10 -2748) provides the primary interface - between the supervised releasing circuit(s) of a Fike fire suppression system and the Impulse Valve Operator (IVO); which is used to release the fire ° t suppressant agent from an impulse valve container The IR.M is equipped with three capacitors that receive a constant charging current from the releasing circut of the control panel. When fully charged, the module is capable of firing a single IVO. Upon circuit activation, the output circuit ,- reverses its output voltage polarity, causing the energy in the capacitors to be released to the Impulse Valve Operator. Each IRM is equipped with a � 1 red LED to provide positive indication that the module is in the active (release) state. .: ' SPECIFICATIONS e • Current Consumption: +24V Supervisory: 20.0 ma (during capacitor charging) 3.0 ma (after capacitor is charged) — -24V Activated: -37.0 ma (LED active) Temperature: 32 °F to 130 °F (0° to 54.4 ° C), 93% maximum humidity Module Wiring: Control panel to IRM connections are supervised and power - limited Impulse Valve Operator (IVO) connection is non - supervised and power- limited Compatible Actuation Devices: 02- 12728, Impulse Valve Operator (IVO) Compatible Releasing Panels: SHP PRO, Cheetah Xi, Cheetah Xi 50 (Note: A maximum of six IRM's, wired in parallel, can be connected to each panel's releasing circuit.) INSTALLATION Each Clean Agent container shall be provided with a Fike P/N 10 -2748 Impulse Release Module (IRM). The IRA•] shall be located at each container and shall be securely mounted in a standard 4" square x 2-1/8" deep UL Listed electrical box. Install conduit and releasing circuit wiring in accordance with the project drawings and appropriate wiring diagrams. All wiring must conform to the requirements of NFPA 70 – National Electric Code, NFPA 72 – National Fire Alarm Code, NFPA 2001 - Standard on Clean Agent Fire Extinguishing Systems, and the requirements of the Local Authority Having Jurisdiction. APPROVALS • UL Listed - S3217 • FM Approved - 3038320 • Cheetah Xi • Cheetah Xi 50 • SHP PRO • CSFM - pending • MEA - pending Form No. IV.1.15.01 704 S W 10th Street • P 0 Box 610 - Blue Springs, Missouri 64013 -0610 U.S.A. (816) 229 -3405 www.fike.com WIRING DIAGRAMS ( -) ( - FROM RELEASING PANEL OR MODULE ( IVO ( +) IVO CIRCU IT emeeme emeewe 00001=C1 0 0 0 0 0 0 + - IVO - + + - NO - + IRM TERMINAL IRM TERMINAL BLOCK BLOCK CLASS B (STYLE Y) WIRING TO RELEASING PANEL OR MODULE I, ( -) FROM RELEASING �— ( -) PANEL OR MODULE (+) IVO ( +) IVO eweeme emeeme 0 0 0 0 0 0 0 0 0 0 0 0 + - IVO - + + - NO - + IRM TERMINAL IRM TERMINAL BLOCK BLOCK CLASS A (STYLE Y) WIRING • I i Ice® Copyright © Fike Corporation All Rights Reserved. Form No. IV.1.15.01 April, 2010 Specifications are subject to change without notice. U.S. and Foreign Patents Pending • 0000 PHOTOELECTRIC SMOKE DETECTOR — - — — • DESCRIPTION " • - - - The Fike P/N 63 -1024 can be used in all areas where Photoelectric Smoke i. Detectors arc required. The wide range smoke chamber makes the 63 -1024 i well sorted for fires ranging from smoldering to flaming fires. r-. The 63 -1028 is a non -listed photoelectric smoke detector. The detector is �� t identical to the 63 -1024, except the 63 -1028 does not have the magnetic test - reed switch, making it suitable for use in areas of high magnetic fields such as MRI's. t • The 4" and 6" smoke detector bases and the 63 -1012, two wire auxilliary P/N 63- 1024, 63 -1028 (non - listed) • relay base may be used with the 63 -1024 and 63 -1028. Current ` — interchangeable /comparable devices are the 67 -1033 ionization detector APPROVALS and the 60 -1029 and 60 -1030 heat detectors. • UL Listed - S4021 • FM Approval - 3010873 Photoelectric Smoke Detector • CSFM - 7272 - 0410:107 Fike P/N Mfq P/N - - 63 -1024 SLR -24V 63 -1028 SLR -24VN Compatible Bases 6" 67 -1034 (430 T) NS6 -224 67 -1035 (220 S2) NS6 -220 Compatible 4° 67 -1036 (430 S2) NS4 -224 67 -1037 (220 S2) NS4 -220 FEATURES • Low profile, 1.8" high (with base) • 2 or 4 wire base compatibility, relay bases available • Highly stable operation, RF /Transient protection • Low standby current, 45uA at 24VDC • Two built -in power /sensitivity supervision/alarm LEDs • Non - directional smoke chamber • Vandal resistant security locking feature • Built -in magnetic go /no go detector test feature • Removable smoke labyrinth for cleaning or replacement • Automatic Sensitivity window verification function meets outlined requirements in NFPA 72, Chapter 7, Inspection, Testing and Maintenance • Compatible with 67 -1033 ionization detectors • Backwards compatible with Hochiki SLK and SIH detectors bases OPERATION The 63 -1024 photoelectric smoke detector utilizes two bicolored LEDs for indication of status. In a normal standby condition the LEDs flash Green every 3 seconds. When the detector senses that its sensitivity has drifted outside the UL listed sensitivity window the LEDs will flash Red every 3 seconds. When the detector senses smoke and goes into alarm the LEDs will larch on Red. The detector utilizes an infrared LED light source and silicon photo diode receiving element in the smoke chamber. In a normal standby condition, the receiving element receives no light from the pulsing LED light source. In the event of a fire, smoke enters the detector smoke chamber and light is reflected from the smoke particles to the receiving element. The light received is converted into an electronic signal. I Form No. P.1.18.01-4 704 S. 10th Street P.O. Box 610 Blue Springs, Missouri 64013 -0610 U S A (816) 229 -3405 • (816) 229 -4615 - www.fike com • • • OPERATION cont. Signals are- processed and compared to a reference level, and when two - consecutive signals - exceeding the reference level are received within a specified period of time, the time delay circuit triggers the SCR switch to activate the alarm signal. The LEDs light continuously during the alarm period. • 63 -1024 Sensitivity Test Feature The 63 -1024 Photoelectric Smoke Detector has a built -in automatic sensitivity test feature. 1. In normal condition, both LED's flash green. 2. When the sensitivity drifts outside of its sensitivity limits, both LED's flash red. 3. In the alarm state both LED's are red continuously. 4. When the sensitivity drifts outside of its sensitivity limits and both LED's flash red, the device needs to be cleaned or returned to the factory for cleaning. Refer to Hochiki Technical Bulletin HA -97 for cleaning information Spacing , • When spacing smoke detectors following the guidelines listed in NFPA 72, base the number and location of sensors on an engineering survey of the area to be detected. The Photoelectric smoke detectors cover 900 sq. ft. SPECIFICATIONS • The contractor shall' furnish and install where indicated on the plans, Fike 63 -1024 photoelectric smoke•detectors. The combination detector head-and twist -lock base shall be UL listed compatible with a UL listed•fire alarm panel. The base shall permit direct interchange with Fike 63 -1025 combination photoelectric /heat detector, 67 -1033 ionization type smoke detector and /or 60- 1029/60 -1030 fixed temperature /rate -of -rise heat detectors. The base shall be appropriate twist -lock base. In the event of partial or complete retrofit, the 63 -1024 maybe used in conjunction with, or as a replacement for, Fike detectors (63 -1007, 63 -1016 and the 67 -1016) on most HSB and HSC base applications. The smoke detector shall have two flashing status LEDs for visual supervision. When the detector is in standby condition the LEDs will flash Green. When the detector is outside the UL listed sensitivity window the LEDs will flash Red. When the detector is actuated, the flashing LEDs will latch Red. The detector may be reset by actuating the control panel reset switch. The sensitivity of the detector shall be capable of being measured. It shall be possible to perform a functional test of the detector without the need of generating smoke. The sensitivity of the detector shall be monitored automatically and . continuously to verify that it is operating within the Listed sensitivity range. To facilitate installation, the detector shall be non - polarized.. Voltage and,RF transient suppression techniques shall be employed to minimize false alarm potential. Auxiliary SPDT relays shall be installed where indicated. • The vandal- resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field removable when not required. Light Source GaAlAs Infrared Emitting Diode Rated Voltage 17.7 - 30.0 VDC Working Voltage 15.0 - 33.0 VDC Maximum Voltage 42 VDC Supervisory Current 45µA @ 24 VDC Surge Current 16011A max. @ 24 VDC Alarm Current 150µA max. @ 24 VDC Air Velocity Range 0 -4000 fpm Ambient Temperattire 32 °F to 120 °F (0 ° C to 49 ° C) Color & Case Material Bone PC /ABS Blend Sensitivity Test Feature Automatic Sensitivity window verification test F . ke® Copyright © Fike Corporation All Rights Reserved. Form No. P.1.18.01 - May, 2007 Specifications are subject to change without notice. • ®04) F ike ORPORATION ______ CONVENTIONAL SMOKE DETECTOR BASES DESCRIPTION 4" and 6" Series Smoke Detector Base The 4" and 6" Series Smoke Detector Bases are designed specifically for use with the 67 -1033 Ionization Smoke Detector, _ 63 -1024 Photoelectric Smoke Detector, 63 -1025 Photoelectric with Heat Smoke Detector, and the 60 -1029 or 60 -1030 � Fixed Temperature /Rate -of -Rise Heat Detector. The 6" base is an electronics free base featuring a plastic tamper -lock lug. Each base is equipped with a resistor. Refer to the chart (below) for additional specifications. The 4" base is a 4" version of the 6" base. Compatible Bases 6" 67 -1034 (430 f) NS6 -224 67 -1035 (220 S2) NS6 -220 < r- ..... Compatible Bases 4" Vi i- - 67 -1036 (430 S2) NS4 -224 67 -1037 (220 S1) NS4 -220 Two Wire Auxilliary Relay Bases Alarm Current 43mA (58mA @ 30.OV Max) Model 63 -1012 is designed specifically for use with the 67 -1033 Ionization Smoke Detector, 63 -1024 Photoelectric Smoke Detector,63 -1025 Photoelectric with Heat Smoke Detector, or the 60 -1029 or 60 -1030 Fixed Temperature /Rate -of -Rise Heat Detector. The 63 -1012 is a 6" base with two sets of Form "C" relay contacts (DPDT, 1 amp at 30 VDC and 0.5 J amp at 125 VAC) when this type of function is needed. It is Underwriters Laboratories approved for releasing device • service. ._.._....... . The 63 -1012 is also approved for use with Fike Conventional Models 67 -1016, 63 -1007, 63 -1016, 60 -1020 and 60 -1022. APPROVALS • UL Listed - S4021 \`.; L • FM Approval - 3010873 CanP¢iUle NS4 Series NS6 Series JL Ucee. t *1 Ai i - -- Co m m Listed -- - - _ i . Panel 4 End of Line Dance L- Panel t- ) _ dil.,,,,,-,.. 4 7K 1 Nega :nE ` 'y I .m V., Tara. War ne.mt NSG as mveolI m:0 m, 4 r. we MUM,.. .0 am. an on ova •..e n an ew m .............1.e...... nG -SAE NS4 Senes NU Series Co UL ' m nn t *t s ^i Card Listed Panel �. �T� ‘C.,* � — 11 End 7K 1. Litre Da•ice 'anal t - ; !!!r -' 4 7K 1/2W Freeel a an,am A. Nepa ?nE ru. l Wimp T.nm.s to no r+s..•e sG.. emo. I Form No. P.1.20.01 -3 704 S. 10th Street • P.O. Box 610 • Blue Springs, Missouri 64013 -0610 U.S.A. • (816) 229 -3405 • (816) 229 -4615 • www.fike.com • • • (This page is left blank intentrona • v e Copyright © Fike Corporation All Rights Reserved. I i CORPORATION Form No. P.1.20 01 -3 June, 2006 Specifications are subject to change without notice. F ID Ike ORPORATION . _ _ . . . . _ CONTROL ACCESSORIES MANUAL RELEASE SWITCH - 10 -1638 <""" DESCRIPTION The Manual Release Switch is a dual actuation device which provides a means of manually discharging the automatic fire extinguishing system when used in conjunction with the Fike • _ - ; j Control Panel. 1 ' To operate the Manual Release Switch pull the spring clip safety pin (breaking the seal) and - • I r depress the button. The switch will remain engaged until released b , unlocking the button , P } g with a key. A single normally open contact block is provided. The front housing of the i `__ Release Switch is constructed of stainless steel with the keyed red plastic release button ' . `' .. centered and bordered in black trim. The dimensions of this component are 4-1/2" wide, 0 fi' - 4-9/16" high and 2 -3/8" deep, and it may be mounted to a standard 4" electrical box or others. (Reference Data Sheet P.1.71.01). - SYSTEM ABORT SWITCH - 10 -1639 4 DESCRIPTION The System Abort Switch is designed to be used in conjunction with other system equipment. % ` It provides a temporary manual means by which the system actuation circuit may be - ` , interrupted, when operated prior to the circuit actuation. The unit employs a momentary 5, —"• contact push button switch. While depressed, the switch causes the agent release circuit to be � �........._, manually delayed. Upon release of the Abort Switch, the release circuit will follow the specific - . -- ` configuration of the system control panel. '� ^ "> } 6 ?. wmr ,ter The Abort Switch may be mounted to a standard 4" electrical box or others (Reference Data �) 1 r Sheet P.1.71.01). ,,,,,• MAIN - RESERVE SWITCH - 10 -1640 DESCRIPTION The "Main" to "Reserve" switch is used with systems that incorporate main and reserve (back-up) agent storage. The switch may utilize 1 or 2 Form "C" Contact blocks which will _ Y .. - V provide an electncal path to either the "Main" or "Reserve" releasing modules. Ma Following a system discharge, reset any field devices. Once all devices are in a stand -by status " I\ 1 .: the Main-Reserve Switch may be moved to the "Reserve" position. The Control Panel may then be reset to to normal mode for uninterrupted Fike protection. The empty "main" A. containers can be removed for recharge. After the containers in the "Main" system have been i "' recharged, the switch may be returned to the "Main" position. f % The switch may be mounted to a standard 4" electrical box or others (Reference Data Sheet P.1.71.01). APPROVALS • UL Listed . • FM Approved • CSFM Approved • BSA I Form No. P.1.72.01 -1 I 704 S. 10th Street • P.O. Box 610 • Blue Springs, Missouri 64013 -0610 U.S.A. • (816) 229 -3405 • (816) 229 -4615 • www.fike.com KEYED ABORT SWITCH - 10 -1642 DESCRIPTION The System Abort Switch is designed to be used in conjunction with other system equipment. • It provides a temporary manual means by which the actuation circuit may be interrupted before automatic actuation occurs. The unit employs a keyed contact switch with two 01 FY positions, normal and abort. While in the extreme left hand position the Abort Switch is in the ' \,.- =,.. - c' "normal" mode. In the extreme right hand position the release circuit is manually delayed. I . a M The Keyed Abort Switch may be mounted to a standard 4" electrical box or others (Reference •YVp Data Sheet P.1.71.01). - Note: Keyed abort is not recognized by approval /listing agencies. KEYED REMOTE RESET - 10 -1641 DESCRIPTION The Keyed Remote Reset Switch provides a method for resetting the Control Panel from a - remote location. To reset the Control Panel simply insert the key and turn in a dock-wise -- - " direction. Upon release of the key the spring loaded switch will return to its original position. r • The front housing of the Keyed Remote Reset Switch is constructed of stainless steel and is I i , 4 -1/2" wide, 4- 9/16" high and 2 -3/8" deep. It may be mounted to a standard 4" electrical j -_ box or others (Reference Data Sheet P.1.71.01) Note: All numbers in this section reference switches and stainless steel face plates only, back box assemblies are not provided. All switches are CSA approved. i Ice Copyright © Fike Corporation All Rights Reserved. Co R P O R A t I O N Form No P.1 72 01 -1 March, 2006 Specifications are subject to change without notice. l DUPONT 0 0 0 0 , :L. T "" FM -200® r - - _ -- 1 FM -200 is also known 1g its ASHRAE designation HFC - -227 ea !I ) APPLICATION /DESCRIPTION — APPROVALS FM -200 provides superior fire protection in a wide range of applications from FM -200 complies with NFPA — sensitive electrical equipment to industrial applications using flammable liquids. Standard 2001 - current edition. Fike FM -200 is ideal for applications where clean -up of other media presents a FM -200 systems are UL listed and problem, where weight versus suppression potential is a factor, where an electrically non - conductive medium is needed and where people compatibility FM approved for Clean Agent Fire is an overriding factor. When environmental impact is a consideration, FM -200 Suppression Systems. is particularly useful. It has zero ozone - depleting potential, low global warming • UL Listed Ex 4623 r.. • potential and a short atmospheric lifetime. These characteristics make it suitable • FM Approved 0Y4A8.AF ' not only for new installations using Fike's total flooding systems, but also for �' • USCG 162.161/2/0 — Halon 1301 replacement applications. t .. - .. FM -200 is an odorless, colorless, liquefied compressed gas. (See Physical Properties -- - Table for additional information). It is stored as a liquid and dispensed into the hazard as a colorless, electrically non- conductive vapor that is clear and does not obscure vision. It leaves no residue and has acceptable toxicity for use in occupied spaces at design concentration. FM -200 extinguishes a fire by a combination of chemical and physical . mechanisms. FM -200 does not displace oxygen and therefore is safe for use in occupied spaces without fear of oxygen deprivation. if ■ n 1. PERFORMANCE FM -200 is an effective fire extinguishing agent that can be used on many types of fires. It is effective for many surface fires, such as flammable liquids, and most solid combustible materials. On a weight -of -agent basis, FM -200 is a very effective gaseous extinguishing agent. The FM -200 extinguishing concentration for normal Class A combustibles is 6.25 - 7% by volume. The minimum design concentration for total flood applications should be in accordance with NFPA 2001. SPECIFICATIONS FM -200 is manufactured to these specifications: • Mole %: 99.0 Minimum • Acidity, ppm by weight: 3.0 Maximum • Water content, % by weight: 0.001 Maximum • Non - volatile residues, gram /100mL: 0.05 Maximum TOXICITY The toxicology of FM -200 compares favorably with other suppression agents. The LC50 of FM -200 is greater than 800,000 ppm. FM -200 has been evaluated for cardiac sensitization via test protocols approved by the United States Environmental Protection Agency. Test results show that cardiac tolerance to FM -200 is higher than that of other suppression agents and is acceptable for safe use in occupied spaces. FM -200 will decompose to form halogen acids when exposed to open flames. The formation of these acids is minimized by using Fike early warning detection systems and proper system installation. When properly applied and installed, the generation of these by- products of FM -200 should be minim Form No. C.1.07.01 -3 I 704 S. 10th Street • P.O. Box 610 • Blue Springs, Missouri 64013 -0610 U.S.A. • (816) 229 -3405 • (816) 229 -4615 www.fike.com • PHYSICAL PROPERTIES Chemical Name . , Heptafluoropropane (CF Molecular Weight 170.03 Boiling Point@ 760 mm Hg 2.55 °F (- 16.4 °C) Freezing Point . ' -204 °F (- 131.1 °C) , ' . Critical Temperature 215 °F (101.7 °C) - Critical Pressure (psia) . . 422 psia (2912 kPa) Critical Volume (ft (cc/mole) 0.0258 (274) • Critical Density (Ibm /ft .. ' . 38.8 (621 kg /m • Specific Heat, Liquid (BTU/16-F°) @ 77 °F (25 °C) 0.283 (1.184 kj/kg / °C) • ' Specific Heat, Vapor (BTU/16-°F) @ constant pressure of 1 ATM @ 77 °F (25 °C) 0.1932 (0.808 kj /kg / °C) • Heat of Vaporization (BTU /lb) at Boiling Point 57.0 (132.6 kj/kg) Thermal Conductivity (BTU /h ft ° F) of Liquid @ 77°F (25 °C) . • 0.040 (0.069 w /m °C) • Viscosity, Liquid (Ib /ft hr) @ • 77 °F (25 °C) 0.443 (0.184 centipoise) Vapor Pressure (psia) @ 77 °F. (25 °C) 66.4 (457.7 kPa) Ozone Depletion Potential ', • ' 0 , Estimated Atmospheric Lifetime (years) - 31-42 LC50 (Rats; 4hrs - ppm) • >800,000 • I I k e Copyright © Fike Corporation All Rights Reserved. DuPont and FM -200 are trademarks or registered trademarks of E.I. DuPont de Nemours and Company. Form No. C.1.07.01 -3 August, 2008 Specifications are subject to change without notice. • o ke )0000 . . IMPULSE VALVE OPERATOR (IVO) KIT DESCRIPTION The Impulse Valve Operator (IVO) provides the means to electrically or - manually activate the Fike Impulse Valve clean agent containers. Upon activation, a pin is extended with the force required to open the inverted rupture disc, allowing the agent to be released from the container. The IVO can be activated either manually by depressing the red button '`�:• ::1 _,. or electrically via a signal from the fire suppression control panel. Once activated, the IVO can be reset using the included reset tool. Fike Clean Agent Containers with Impulse Valve use an Impulse Releasing Module (IRM) to supervise the agent release circuit wiring (for open and _ ground fault conditions) from the container to the control panel. Up to 6 IRvL's may be released from a single Fike fire suppression control panel. I An IVO kit is included when ordering an Impulse Valve clean agent container with electric actuation. The kit includes the following components: • r . - Fike P/N Description 02 -12728 IVO 70 -286 Reset Tool Impulse Valve Operator 02 -12755 Wire Lead (3' long) with connector 10 -2748 IRM ■C i SPECIFICATIONS Reset Tool Normal Supply Voltage: 24VDC Current Consumption: 0 Amps (for Battery Calculation) I Electrical Connection: DIN connector w/ Cable & ' /2" NPT 0 ° 0 O ° 0 or for conduit connection O ❑❑ IVO Material: Stainless Steel (Body) / Brass (End Cap) Temperature Range: 32 °F to 130 °F (0 °C to 54.4 ° C) IRM APPROVALS • UL Listed - Ex4623 • FM Approved - 3014476 Wire Lead with Connector Form No. IV.1.09.01 704 S.W. 10th Street • P 0 Box 610 • Blue Springs, Missouri 64013 -0610 U.S.A. • (816) 229 -3405 • www.fike.com ELECTRIC ACTUATION - SINGLE CONTAINER SYSTEM WITH IVO W CO3 1 — IRM Assembly (pin 10 -2748) MI Discharge Pressure Switch (pin 02- 12534) E –. -- > - P [ [ �•. IVO wl Manual Strike Button ELECTRIC ACTUATION - MULTI- CONTAINER SYSTEM WITH IVO Maximum of 61RMs can be wired to a Fike Control Panel single Fike Control Panel) r - i r > cto c x baD4— 1RM Assembly (p /n 10 -2748) �, d V I ®ii. W if : 3, 3 �. H IVO w/ Plastic Cap / Manual Strike Button removed (Typical for containers) Note: When utilizing electric actuation (IRM) with multiple containers with IVO, the manual strike button on each IVO must be removed and plastic cap installed. This is to prevent a single container from being discharged in a multiple container system. For wiring installation details between Fike Control Panel, IRM and the IVO, reference the Impulse Release Module (IRM) Product Manual (p /n 06 -552). ' ke Copyright © Fike Corporation All Rights Reserved. Form No. IV.1.09.01 April, 2010 Specifications are subject to change without notice. U.S. and Foreign Patents Pending III l i k e .� 0000.4 ._ HFC -227EA INSTRUCTIONAL SIGNS i APPLICATION Instructional signs must be supplied in order to provide a system in which the function of all devices is easy to understand. Fike offers several different "standard" signs that comply with NFPA and other industry requirements. All signs are durable - plastic and backed with a strong adhesive for easy installation. Signs are typically installed at all entrances (CAUTION - ! , --- Room Protected By HFC - 227ea) and near any device for which the extra explanation is helpful. Custom signs are available (. : i. . ) . upon special request. L. SYSTEM 'RELEASE" SIGN /MANUAL RELEASE STATION (P /N 02- 10137) / DESCRIPTION - ` The purpose of the System "Release" Sign is to identify the manual release station as the place where the HFC -227ea HFC -227ea System can be manually discharged. It also minimizes the possibility of the manual station being mistaken for a fire __;, EXTINGUISHING alarm device. The sign is 4" x 2.25" x 1/16" (102 x 57 x I - - 1.6mm) and is constructed of white plastic with red lettering. ' i SYSTEM RELEASE The System "Release" Sign should normally be located under - each HFC -227ea manual release station for quick positive ' j ; identification.`! [ --` 1 T UPON DEVICE ACTIVATION "DO NOT ENTER" SIGN 411" ...... (P /N 02- 10138) DESCRIPTION The purpose of the System Discharge Sign is to explain the ACAUTION presence of an alarm in the event of a HFC -227ea System discharge. The sign is 9" x 6" x 1/16" (229 x 152 x 1.6mm) HFC-227ea EXTINGUISHING and is constructed of white plastic with black lettering and SYSTEM DISCHARGE ALARM yellow caution background. The System Discharge Sign is located next to or under an audible or visual alarm outside of IF ACTIVE the protected space entrance(s). This sign, together with the DO NOT ENTER AREA alarm device(s) will alert personnel when HFC -227ea agent has discharged and allow them to take appropriate actions. CAUTION "DO NOT ENTER" SIGN 14( ......... (P /N 02- 10139) DESCRIPTION The purpose of the Caution Sign is to alert personnel that the ACAUTION room is protected by an HFC -227ea System and that all doors should be kept closed in the event of fire. The sign is 10" x THIS AREA IS PROTECTED BY A 13" x 1/16" (254 x 330 x 1.6mm) and constructed of white HFC - 227ea EXTINGUISHING SYSTEM plastic with black lettering and yellow caution background. The Caution Sign should normally be located on the entrance DO NOT ENTER AREA DURING door(s) leading into any room where HFC -227ea protection is OR AFTER DISCHARGE being provided. KEEP DOOR CLOSED AT ALL TIMES Form No. C.1.10.01 - 4 I 704 S. 10th Street • P.O. Box 610 • Blue Springs, Missouri 64013 -0610 U.S.A. - (816) 229 -3405 • (816) 229 -4615 • www.fike.com UPON DEVICE ACTIVATION "EXIT" SIGN 41 (P /N 02- 10105) DESCRIPTION A T I O N' The purpose of the System Discharge Sign is to explain A the presence of an alarm in the event of an HFC -227ea System discharge. The sign is 9" x 6" x 1/16" (229 x 152 HFC - 227ea EXTINGUISHING x 1.6mm) and is constructed of white plastic with black SYSTEM ALARM lettering and yellow caution background. The System Discharge Sign is located next to or under an audible IF ACTIVE or visual alarm inside of the protected space. This sign, EXIT AREA IMMEDIATELY together with the alarm device, will alert personnel when HFC -227ea agent has been discharged and allow them to take appropriate action. SYSTEM ABORT "PUSH AND HOLD" SIGN (P /N 02- 10106) DESCRIPTION The purpose of this System Abort Sign is to identify HFC -227ea the presence of the HFC -227ea System Abort Station. EXTINGUISHING The sign is 4" x 2.25" x 1/16" (102 x 57 x 1.6mm) and is constructed of white plastic with red lettering. The SYSTEM ABORT System Abort Station is designed to provide a manual means by which the HFC -227ea system actuation circuit PUSH AND HOLD may be interrupted. The System Abort Sign should be located next to each HFC -227ea Abort Station for quick positive identification. SYSTEM "MAIN /RESERVE" SIGN (P /N 02- 10107) DESCRIPTION The purpose of Main /Reserve Sign is to identify the presence of the HFC -227ea Main /Reserve Switch Station. HFC -227ea The sign is 4" x 2.25" x 1/16" (102 x 57 x 1.6mm) and is EXTINGUISHING constructed of red plastic with white lettering. The Main/ Reserve Sign should be located under the Main /Reserve SYSTEM Switch for positive identification. A .Main /Reserve Switch is used with systems that incorporate main and reserve MAIN / RESERVE (back up) HFC -227ea Agent storage. J RELEASE PENDING SIGN (P /N 02- 10268) DESCRIPTION HFC -227ea The purpose of the Release Pending Sign is to explain the presence of an alarm in the event of an impending RELEASE HFC -227ea System discharge. The sign is 7" x 4.25" x PENDING WHEN 1/16" (178 x 108 x 1.6mm) and is constructed of red plastic with white lettering. The Release Pending Sign DEVICE IS ACTIVE is located next to an audible or visual alarm inside of the protected space. This sign, together with the alarm - device, will alert personnel of a forthcoming HFC -227ea EXIT AREA Agent discharge and allow them to take appropriate action. II kee Copyright © Fike Corporation All Rights Reserved. Form No C.1.10 01-4 August, 2009 Specifications are subject to change without notice. • e o00® DUPONT"' FM -200® AGENT STORAGE CONTAINERS • FM -200 is also known by its ASHRAE designation HFC -227ea DESCRIPTION Fike Clean Agent Containers are used in fire extinguishing systems to store the Clean Agent until a fire develops and the agent must be released. The Clean Agent is retained in the container by a - impulse valve assembly which contains a fast - acting rupture disc. The disc will be ruptured, and the Clean Agent released, through the operation of an actuator by an electric signal that is - - - -' automatically or manually controlled. Fike Clean Agent Containers have passed extensive testing by Factory Mutual and Underwriters Laboratory and are used in installations where 12 to 1045 pounds (5.5 to 474 kg) of FM -200 �.__.• agent is required. Clean Agent containers can be filled in 1 pound (0.5 kg) increments to then _ maximum capacity. 1" Impulse Container r._..._.. Each container for FM -200 Clean Agent Systems is super pressurized with dry nitrogen to I/ 360 si (25 bar), at 70 ° F 2 1 °C , to provide a quick and effective discharge in 10 seconds I- P g (- ) (- ) P 9 or less. I s Fike Clean Agent Containers are supplied with a mounting bracket and pressure gauge that permits — a quick visual inspection of container pressure. Containers with a 3" (80mm) discharge valve, _._. 150 -lb (61 L) and up, are equipped with a Liquid Level Indicator that allows a convenient method for determining the container agent weight without removing it from the installed location. An optional Low Pressure Supervisory Switch is available to provide constant monitoring of the internal pressure of the container. In the event of a decrease in container pressure below 288 psi (18.8 bar), the Supervisory Switch will change states, causing a supervisory trouble at the control panel. Fike Clean Agent Containers are available for installation in the upright, inverted or horizontal positions, depending upon the user's particular needs and the type and size container specified. — _ = =— The mounting location of the container is flexible. It can be mounted at the point of discharge 3" Impulse Container or at a remote location by adding distribution piping. RELIABILITY Fike Clean Agent Containers are manufactured in strict accordance with Department of y� .. Transportation (D.O.T) regulations. The Fike Clean :Agent Containers have successfully passed testing by Factory Mutual and Underwriters Laboratories, Inc. Before leaving the factory, each container must pass extensive leakage testing, and pressure testing to 1000 psig (69 bar). The -- containers are constructed from carbon steel alloys and painted with a durable, baked enamel ✓� finish. Inverted 150 lb. APPROVALS Impulse Container • UL Listed - Ex 4623 • FM Approved - 3014476 Form No. IV.1.01.01 704 S.W 10th Street • P O. Box 610 Blue Springs, Missouri 64013 -0610 U S A. (816) 229 -3405 www.fike.com Page 1 CONTAINER DATA/SPECIFICATIONS Container Fill range Tare Dimensions (approximate) . Valve Size Weight Height Mounting Diameter Size Minimum Maximum 9 Position Lb. (L) P/N lbs. (kg) in. (mm) in (mm) lbs. (kg) in. (mm) in. (mm) 20* 70.263 12 21 1 21 7.0 22.375 Upright - (8) (5.5) (9 5) (25) (9.5) (178) (568.3) Honzontal 35* 70-264 22 38 1 31 7.0 32.5 Upright - (15) (10.0) (17.0) (25) (14.5) (178) (825.5) Horizontal 60 70-265 39 68 1 52 10 75 28 Upright - (27) (18 0) (30 5) (25) (23 6) (273) (711.2) Horizontal 100 70 -266 63 108 1 77 10 75 38.75 Upright (44) (28.5) (49 0) (25) (34 9) (273) (984.3) (Valve Up) 150/1501 70 267 87 150 3 150 20.0 23.63 Upright/Inverted (61) (39.5) (68.0) (80) (68.0) (508) (600.1) 215 70-268 124 216 3 155 20.0 28 87 Upright (88) (56 5) (98.0) (80) (70.3) (508) (733 3) (Valve Up) 375 70-269 217 378 3 225 20 0 42.5 Upnght (153) (98 5) (171.5) (80) (102.1) (508) (1079.5) (Valve Up) 650 70-270 378 660 3 385 24 0 50.625 Upright (267) (171.5) (299.0) (80) (174 6) (610) (1286) (Valve Up) 1000 70-271 598 1045 3 550 24.0 70 Upright • (423) (271.5) (474 0) (80) (249.5) (610) (1778) (Valve Up) Fill Range 40 to 70 lbs/ft 630 to 1121 kg /m Fill Increments 1 0 lbs 0 5 kg Container Super - Pressurization Level 360 psig at 70 °F (24.8 bar at 21°C) after filling with dry nitrogen Container Storage Temperature Limitation 32 °F (0 °C) - minimum 130 °F (54 4 °C) - maximum Container Rating DOT 4BW500 TC 4BWM534 Note: * The 20 lb. (8 L) containers and 35 lb. (15 L) containers filled to less than 25 lb. (11.5 kg) are only approved by FM Approvals. Page 2 ITEMS SUPPLIED WITH CONTAINER Along with a name plate and siphon tube, all Fike clean agent containers are supplied with the following: 1 g i Impulse Valve f I This valve is a rupture disc (metal diaphragm), pressure operated device that allows the agent to be released from the container and into the protected via the associated piping i i t network and discharge nozzle(s). - --- -- v The discharge valve also fulfills the pressure relief valve requirements in accordance _ with DOT regulations. ' :.r rg Victaulic Nipple and Coupling Used to connect container to the discharge piping network. Impulse Valve For shipping purposes, a baffle plate is inserted into the Grooved Coupling " r" 4 1 as a safety device. ' Discharge Replacement Description r •" *J . Valve Size P/N .. 1" Discharge 02 -9964 1" diameter (25 mm) Victaulic Coupling I `� .,1, Valve 02 -10042 1" diameter (25 mm) x 3" (76 mm) long Nipple " 3" Discharge 02 -1987 3° diameter (80 mm) Victaulic Coupling 4001110 Valve 02 -2106 3" diameter (80 mm) x 4.5" (114 mm) long Nipple Victaulic Nipple and Coupling ARCHITECT AND ENGINEERING SPECIFICATIONS The Clean Agent shall be stored in Fike Clean Agent Storage Containers. The containers shall be capable of being filled, in one -pound (0.5kg) increments, to their listed maximum capacity. The Clean Agent container shall be activated by a signal from the control panel which is processed by the Agent Release Module. This module shall store the power required to operate the actuator. The valve shall contain a scored, non - fragmenting, rupture disc to provide an immediate, total discharge of all the agent. FM -200 Clean Agent is stored in the container as a liquid, having a natural vapor pressure of 200 psig at 77 °F (13 barg at 25 °C). To aid in discharge, the container shall be super - pressurized to 360 psig at 70 °F (25 bar at 21 °C) with dry nitrogen. Agent discharge shall be completed in 10 seconds or less. Clean Agent Storage Containers shall be actuated by an electrical signal that is automatically or manually controlled. Normal operating temperature shall be +32° to +130 ° F (0 to 54 °C) in any installation. Clean Agent Storage Containers shall be equipped with a pressure gauge to display internal pressure. This gauge shall be an integral part of the container and color coded for fast referencing of pressure readings. A Low Pressure Supervisory Switch shall be made available, as an option. A decrease in internal container pressure from 360 to 288 psig (24.8 to 18.8 bar) shall cause the normally opened /closed Supervisory Switch contacts to close /open, indicating a trouble or supervisory condition, at the control panel. Clean Agent Storage Containers shall be fastened to a wall, or other secure surface, using an optional mounting bracket that . is designed for the most effective and versatile installation of each container. ' I C © svd. DuPont opyright and FM -200 Fike are Corporation trademarks All Rights or registered Reere trademarks of E.I. DuPont de Nemours and Company. Form No. IV.1.01.01 April, 2010 Specifications are subject to change without notice. U.S. and Foreign Patents Pending Page 3 li ° �� AIR IMPULSE VALVE — - -- DESCRIPTION The 1" & 3" Impulse Valves are a rupture disc (metal diaphragm), pressure - - — operated device that allows the agent to be released from the container and -- into the protected enclosure via the associated piping network and discharge { i nozzle(s). w .I , Fike Impulse Valves are equipped with four ports: -__ s I i � w • Agent Discharge Port allows agent release from container and also I i i fulfills the pressure relief valve requirements in accordance with DOT f t . regulations. • Agent Fill Port used to fill (refill) and pressurize the container and also al! a ' used for the Low Pressure Switch. """""'""" — , • Actuator Port used to connect an Impulse Valve Operator (IVO) with I ._ Manual Strike Button for electric and manual actuation of the container l� , ' or an Impulse Valve Pneumatic Operator (IVPO) for pneumatic - '_ L operation. •. • Pressure Gauge Port is used to connect a Pressure Gauge that will monitor internal container pressure, also equipped with an orifice " -- ' plug that allows the pressure gauge to be removed safely when the I _ • container is pressurized. SPECIFICATIONS Valve Body: Brass Rupture Disc Assembly: Hastelloy C276/316SST APPROVALS • UL Listed - Ex4623 • FM Approved - 3014476 Discharge Port ► -' 1; 11 I . t Pressure Gauge Port , Y RO Port —e• Fes 1" Impulse Valve Rupture Disc Assembly —► ' - •, Discharge Pon l hl • ' r ', -. � Presume taupe i RU Pon :- ' Pressue Gauge Pon 'e '! � — --` - ; 3" Impulse Valve Actuator Port I Form No. IV.1.14.01 I 704 S.W 10th Street • P.O. Box 610 • Blue Springs, Missouri 64013 -0610 U.S.A. • (816) 229 -3405 • www.fike.com ' 1 • • • • • • • (This page is left blank intentional}) • • • • F..ke. Copyright © Fike Corporation All Rights Reserved. Form No. IV.1.14.01 April, 2010 Specifications are subject to change without notice. U.S. and Foreign Patents Pending • 1ke� @ 00 0 * FIKE ENGINEERED NOZZLES FOR FM -200® CLEAN AGENT SYSTEMS FM -200 is also known by its ASHRAE designation HFC -227ea ; DESCRIPTION The function of the Fike Engineered Discharge Nozzle in a fire extinguishing system - - is to distribute the Clean Agent in a uniform, predetermined pattern and concentration. - _ The nozzles are designed to complete the discharge of Clean Agent in 10 seconds or r i less when installed within the design limitations of the Fike Design, Installation and Maintenance Manual, P/N 06 -202 or 06-215 and the Fike Flow Calculation computer program. f • of Fike Engineered Discharge Nozzles are available in sizes of 3/8" (10mm) through 2" (' ') ' (50mm). Each nozzle is available in 180 and 360 degree discharge patterns. a .•. :» The Discharge Nozzle size refers to the size of Schedule 40 or 80 steel pipe to which it .• i'.•.'.: can be connected. The nozzle discharge orifices are drilled perpendicular to the center line of the threads. The nozzles are mounted to allow the agent to be discharged on a APPROVALS horizontal axis. • • UL Listed - Ex4623 • ULC Listed - CEx1136 [3 L11 Nozzle orifices are available in a wide range of sizes to provide accurate Clean Agent • FM Approved - 0Y4A8.AF r- flow results. All nozzles have been tested for their ability to discharge the Clean Agent under extreme conditions. Nozzle orifice drilling must be done at the Fike factory, or other UL listed nozzle drill station, only after "As-Built" calculations of the installed piping system(s) have been performed, using the Fike Flow Calculation computer program. The Fike Discharge Nozzle used shall be Factory Mutual (FM) approved and Underwriters Laboratories (UL) listed. ARCHITECT AND ENGINEERING SPECIFICATIONS The nozzle used to disperse Clean Agent shall be a Fike Series 80. The nozzle shall be available in 3/8" (10mm) thru 2" (50mm) sizes. Each size shall be available in both 180 and 360 degree dispersion patterns. The nozzle used shall have pipe threads that correspond to the nozzle size. All nozzles shall have an orifice size determined by a UL listed and FM approved flow calculation program. All nozzle orifice drilling shall be performed by the manufacturer or a UL listed nozzle drilling facility. Form No. C.1.08.01 -4 I 704 S. 10th Street • P.O. Box 610 • Blue Springs, Missouri 64013 -0610 U.S.A. • (816) 229 -3405 • (816) 229 -4615 • www.fike.com • • • • • • NOZZLE SIZE AND AREA COVERAGE _ R R - 180 ° NOZZLE • 360° NOZZLE Nozzle Area Coverage " Nozzle Type " R Ceiling Height • Dimension • Range 180 Degree 45' - 8° (13.92) 1.0 to.16.0 (0.3 to 4.9) • 360 Degree 29' - 8" (9.04) 1.0 to 16.0, (0.3 to 4.9) NOZZLE SIZE . 180° NOZZLE 360° NOZZLE • (NPT) (mm) PART NUMBER PART NUMBER 3/8" (10) 80 -060 80 -052 1/2° (15) 80 -061 80 -053 3/4" (20) 80 -062 80 -054 • 1" (25) 80 -063 80 -055 1 1/4° _ (32) 80 -064 80 -056. 1,1/2° (40) 80 -065 80 -057 • 2° (50) 80 -066 - 80 -058 NOTES: a. The maximum allowable area of coverage includes any area within the radius distance from the nozzle (`R" dimension) to • the most extreme wall or corner. b. Nozzles should be located on center line of hazard area. • c When working with ceiling heights exceeding the values tabulated above, the hazard volume must be broken down into vertically stacked hazard volumes, with heights less than the maximums shown in the table. It is imperative that unusual applications of this nature be handled by experienced design engineers and, in most cases, operational tests should be performed before the system is put into service. d. Dimensions and nozzle data shown are taken from the UL listed and FM approved Design, Installation & Maintenance Manual - P/N 06 -202 or 06 -215. e. 180 and 360 degree nozzles may be placed a maximum of 1 foot (30.5cm) down from the ceiling, and 180 degree nozzles may be placed a maximum of 1 foot (30.5cm) from the wall. f. Nozzle threading is NPT. • k ® Copy Fike DuPont right and © FM -200 are Corporation trademaAll rks Rights or registered Reserved trademarks of E.I. DuPont de Nemours and Company. Form No. C.1.08.01 -4 August, 2008 Specifications are subject to change without notice. S �, o I AV S� g swimity, UL LISTED J.,git AudibleNisuals h The IAVs are the Strobes, Lamps and Sounders of ; _ • the Infinity line. These units are Listed for General 1 ,- = Signaling and are perfect for the rising popularity of Mass Notification Systems. All the units fit the Sijimit Series Plates. - - The Strobes (IAVSTR) and Lamps (IAV -SLM and IAV FLM) of the IAV Line are 12, 24 and 120 volt I ••• units. They fit the IGP Plates and the IGB Boxes. • •• • These units are not synchronized. ..... The Synchronized Strobes (IAV -SST) are 24 volts Ti DC only and must be used with the IAV SYNMAS (Master Sync Module) or the IAV - SYNSLA (Slave Sync Module). Standard Features: The Horn (IAVHORN) is a Piezo driven Mini -Horn, • Incandescent Lamps and Xenon Strobes 12/24 VDC with HI /Low sound settings. available • Utilizes standard Infinity IGP plate design The IAV GSP is the General Signaling Platform that allows adaptation to surrounding for the St Line. It allows for the mounting architectural design features, red, white, of two IAV STROBE or LAMP units along with stainless steel & yellow available a 4 "Square sounding device (Horn or Speaker • Strobes /Lamps available in 12, 24 and 120 supplied by others). Volt versions • Horn available in 12/24 Volt versions • Durable steel frame mounts into an Sai GSB Box or a standard electrical VBUILDINGS back box ,- • Multiple colored lenses allow the Strobes/ • - Lamps to fit any application ('F.,s, •wv �.' • ADA ISO 9001 Al rt - 4 REGISTERED �� y� Space Age Electronics, Inc. NFPA Made r...../ . COMPANY ��WM•M www.1sae.corn 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax Space Age Electronics, Inc. 2007 ED0433 LT10442 Rev.A 1/2 No Excuses, Just Solutions! • SPA C EAGE ELECTRONICS, INC. Specification: • The IAV Sty. Audible Visuals shall be custom -built through its modularity and utilization of standard or multi gang electrical mounting boxes and 1 -6 capacity Infinity style face plates. I J. 1 i i . 1 1 ll I Modular design expandable Horn and Strobe with appropriate Infinity to accommodate up to six modules face plate illustrate the assembly and modularity of the IAV Series :K Ilor PLATE SEa I :' Std �i7R+ xtrF+ 1-1 /4' — 4 $CUML YDWiNC Speciality trim rings such as the GSP are engineered for '��. g �_ �j � � - . I iwru:m PLATE s[rts special applications such as �/ •0{� Mass Notification. CC � I i'iF:Lf BOX— \,,,, Al rt Agency Approvals: Space Age Electronics, inc UEES.E56737 UL Listed Visual-Signal Appliance www.l corn pp 800.486.1723 Toll Free 7300.0553 -002 California State Fire Marshal (CSFM) Strobes Only 508485.0966 Local 160 -94 -E B NYC Department of Buildings (MEA) 508.485.4740 Fax This document is subject to change without notice, see doc # ED0479 for legal disclaimer No Excuses, Just Solutions! ED0433 LT10442 Rev.A 2/2 lAy I AV 43,skf5'• _ SE,,N • . o kk LISTED • Jilig. STROBES, LAMPS ''ti��' & Horns A The IAVSTR 9..t.:.«tg. Strobe unit along with its "' Incandescent IAVFLM and IAVSLM offers a broad �`. • , , range solution to your General Signaling needs. The j 9 t Visuals come in 12, 24 and 120 Volt units . f • the Incandescent Lamps come as either flashing or • non - flashing. The IAV Series Strobes /Lamps come with colored lenses to allow the visual signals to fit any 1, application. The lenses come in red, blue, clear, , c amber, white and green. A ••■ The IAVHORN is a piezo driven white mini -horn with \\ an operating voltage range of 12/24 VDC each with a ‘'. an HI and Low setting making it's range 78 to 53 dBA @ 24 VDC and 73 to 48 dBA @ 12VDC. Standard Features: Units install into standard or multiple gang electrical boxes (IGB). Optional red, white, stainless steel or • IGP plates are scalable to meet your capacity yellow IGP plates house up to six units. requirements as well as color requirements • IGP plate is removable to allow for easy lAVs are compatible with all IAM and ICM units and access to field wiring and troubleshooting can be mounted in the same inclosure. • Durable steel frame mounts into an Infinity IGB Box or a standard electrical back box and securely holds the cover IGP plate. * • -- • Standard mounting hardware included. ____ • • Optional 1 x 3 inch Plaque available: 6 Area of Rescue ADA \ i • Nurse Call • Hazardous Area 4,�, -------_ I _: • Halon /FM200 Discharge I. �' z BUILDINGS • ISO 9001 Al rt - Gijo REGISTERED I` _! Space Age Electronics, Inc. C OMPANY E �`�W!'IN www.1sae.com NFP/F Made In U.S.A. 800.486.1723 Toll Free 508 485.0966 Local 508 485 4740 Fax Space Age Electronics, Inc. 2007 No Excuses, Just Solutions! ED0435 LT10444 Rev.A 1/2 SPACE AGE ELECTRONICS, INC. Specifications: The IAV series of Audio/Visual devices, including strobes, lamps and horns shall be of a configuration to fit into the IGB series of back boxes and the utilize the J.til-ty. Plates. The visual units shall be Listed for General Signaling Purposes. The strobes shall be a minimum of 15 cd and range in voltage from 12 VDC, to 24 VDC and 120 VAC. The horn shall produce no less than 78 to 53 dBA @ 24 VDC and 73 to 48 dBA @ 12VDC dependant on their Hi and /or Low settings and shall have voltage ranges from 12 to 24 VDC. All IAV modules use the clinch type of terminal connectors for field wiring. Ordering Information: Part number Description Current Draw Flash /Minute IAVSTR24 Xenon Strobe 115mA @ 24VDC 60 IAVSTR12 Xenon Strobe 155mA @ 12VDC 60 IAVST120 Xenon Strobe 30mA @ 120VAC 60 IAVSLM24 Steady Incandescent 96mA@ 24VDC NA IAVSLM12 Steady Incandescent 125mA@ 12VDC NA IAVSL120 Steady Incandescent 50mA@ 120VAC NA IAVFLM24 Flashing Incandescent 96mA@ 24VDC 30 approx. IAVFLM12 Flashing Incandescent 125mA@ 12VDC 30 approx. IAVFL120 Flashing Incandescent 50mA@ 120VAC 30 approx. IAVHORN * Infinity Mini Horn (White) 25mA@ 24VDC HI NA 2.5mA@ 24VDC LO NA 73mA@ 12VDC HI NA 2.7mA@ 12VDC LO NA For Lens Color add to the above Part Numbers: "A" for Amber, "B" for Blue, "C" for Clear, "G" for Green, "R" for Red and "W' for White (Example IAVSTR24R = a 24 VDC Strobe with a Red Lens) Order the 941*.mit Plates (IGP) and Back boxes (IGB) separately! * Not UL Listed None of the above are synchronized (See IAVSST24 Strobes). Agency Approvals: UEES.E56737 UL Listed Visual- signal Appliance ,- Red = Positive (-) 7300.0553 -002 California State Fire Marshal (CSFM) ` ?Mom ' slack = N ®� egative Foraoli) Strobes Only 160 -94 -E B NYC Department of Buildings (MEA) Typical Space Age Electronics, Inc. Wiring L ow pp www.1 sae. com 800.486.1723 Toll Free Strobe Horn 508.485 0966 Local /Light 508.485 4740 Fax This document is subject to change without notice, see doc # ED0479 for legal disclaimer No Excuses, Just Solutions! ED00435 LT10444 Rev.A 2/2 AsfS• o I G B g „L • 0 kIL LISTED Jed Gang Back Box = Single Gang The IGB -1 indoor /outdoor back box is the most versatile of the J..k:,at IGB back boxes. Made from heavy duty cast aluminum with a - durable powder coat backed on finish (red or - • white) this indoor /outdoor box will house a single ^. _ 9.t. unit, be it the IAM4Z annunciator through to the more advanced ICMHOA smoke control modules, as well as the IAV Devices. Suitable for mounting in wet locations with proper installation and gasket kit. Standard Features: Ordering Information: •Dim 2.75" x 4.5" x 2.0" deep Part # Description •Heavy duty die cast aluminum (.094 thk.) •Durable white or red finish IGB1W BACK BOX 1 GANG WHITE •UL Listed • IGB1R BACK BOX 1 GANG RED •Ground screw and 2 close -up plugs supplied with each box Accessories: •Pre- tapped ground screw hole Outdoor gasket kit not included with box •1/2" I.P.S. rigid conduit connections Order IGB1WPK one in each end and one on the back • • �J ADA ISO 9001 Al rt REGISTERED Ex Space Age Electronics, Inc. NFPA Made In U.S.A. COMPANY ��- www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508 485 4740 Fax This document is subject to change without notice, see doc # ED0479 for legal disclaimer ED0441 LT10451 Rev.A 1/1 No Excuses, Just Solutions! o I G B ,,s. g mi 0 �9a�9'Q g dt Gang Back ° Boxes The IGB Surface Back Boxes are the ideal solution for surface mounting the 2 to 6 Gang Infinity devices. The IGB boxes are designed with attention to installation needs. Each box is designed with a solid surface area with pre - drilled and tapped hole configurations to mount 9a �g the majority of industry appliances /devices. Durable 18 gauge steel finish in red or white professional grade baked on enamel finish. Each box comes with standard 1/2" & 3/4" EMT knockouts strategically located on the box. l Universal mounting pattern in the box for surface installation. The rugged construction and aesthetic appeal makes the IGB surface k0 back box your logical choice for surface mounting 2 thru 6 gang appliances in your next design installation. Standard Features: • 18 gauge steel (.048 thk.) 92P9 • Textured baked -on enamel finish (red or white) • 1/2" & 3/4" embedded EMT knockouts • Infinity device mounting holes • Universal mounting pattern • • • ( ! \ �� ISO 9001 REGISTERED 69a�0 Made In U.S.A. COMPANY ADA r /��_ Al rt ono riftswl- Space Age Electronics, Inc NFPR www. l sae. corn 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax Space Age Electronics, Inc. 2007 ED0440 LT10450 Rev. A 1/2 No Excuses, Just Solutions! SPACE AGE ELECTRONICS, INC. Description: The 9. IGB Surface Back Box is constructed of 18 gauge cold rolled steel with a durable heat resistant baked -on enamel finish. The box will have factory EMT cluster knockouts 1/2" and 3/4" embedded into the enclosure (sides and back). The box will have a minimum of 4 mounting holes to affix the box to the wall surface. The box will provide a minimum of a 1/4" shoulder to level field mounted appliance on back box. Back box shall be a Space Age Electronics, Inc. IGB series surface back box. Overall Dimensions of Back Box 0 0 0 T. o T 2 } o T cv v 0 qv 0 0 Ce0 0 4 5/8" ' O c 4 5/8" O O 4 5/8" O O O °� fj o o ° o . L O • O O • O O 0 0 0 0 0 o O n 8 8 .-- 4 5/8-4- 1•— 6 1 /2" 1.1-8 3/8" 2 Gang /4" square 3 Gang 4 Gang T T T T n T ► O 4 + O Q O : O ° 0 O a o 4 5/8" L O O 0 4 5/8 O o O 0 0 o o 8 n 8 0 0 0 0 0 10 3/16" I 14 12" ►I 5 Gang 6 Gang Ordering Information: Part # Description H W D IGB2W Back Box 2 gang surface white 4 -5/8" 4 -5/8" 2" IGB2R Back Box 2 gang surface red 4 -5/8" 4 -5/8" 2" IGB3R Back Box 3 gang surface red 4 -5/8" 6 -1/2" 1 -3/4" IGB4R Back Box 4 gang surface red 4 -5/8" 8 -3/8" 1 -3/4" • IGB5R Back Box 5 gang surface red 4 -5/8" 10- 3/16" 1 -3/4" IGB6R Back Box 6 gang surface red 4 -5/8" 12" 1 -3/4" Alk rf , 1l ' Space Age Electronics, Inc. www.1 sae. com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax This document is subject to change without notice, see doc # ED0479 for legal disclaimer No Excuses, Just Solutions! ED0440 LT10450 Rev.A 2/2 0 I G P . :,,,,°s'e g sogi t zpoiLtv • • . ° ®1. LISTED , Gang Plates I It all starts with the plate. This "Decora" style design is the basis of the 9KjL t Line. It is the basic building block upon which the whole El i product line revolves. I Space Age Electronics is proud to announce the J.I-t,.it Line of Solutions Based Products. Sty. is Flexibility! 947*.,.:t is Simplicity! 9 is Fire, Security, HVAC, Building Automation! 9 ...g.mit g . is Annunciation, Control, Notification! m St is Integration! 9...tim t is all this and more, it is the melding together of products that can Alert, Manage and Identify the functions that are faced n buildings o '• - ° around the globe. Functions like Fan and Damper Control, Fire Standard Features: Alarm Annunciation and Fire Suppression • Universal Recognition of the "Plate" Signaling can now be contained on a single • The name "9...k&git means there are no "gangable" and "customizable console. pre- conceived limits to design • Customizing is a natural for this "modular" And that is just the beginning, Utilizing the type of product format of the familiar " gangable" device mount • No "in- house" manufacturing /configuring, work boxes, we can grow the 9...a-:,.tt. line far 1 from Column A, 1 from Column B beyond it's current product offering. Think of approach. it, a factory custom, You tell us your need and • Listing is done on a module by module we will design the solution to fill that need, as basis long as it fits the Infinity plate format. Switches, • All inputs and outputs are relay or switch Lights, Timers, anything The possibilities are contacts = Universal Compatibility!! Infinite!!! ISO 9001 -, 51 REGISTERED �� `.-!s A I; =1t Vi COMPANY Space Age Electronics, Inc. NFPR r M ade In U.S.A. /: 1\ 1 • \ r •. ! ;, s fi, r ` �, < ; r 7' www. 1 sae.com 1 , = ) s ' , f i '! � `-. ' ._i_. , . %:= ' , _,; j r' v.. •`," �.i ` 800.486.1723 ToII Free _ 508.485.0966 Local 508.485.4740 Fax Space Age Electronics, Inc. 2007 No Excuses, Just Solutions! ED0432 LT10441 Rev.A 1/2 • SPACE AGE • ELECTRONICS, INC. Specifications: -- -. - - . - All Jty devices fit the "single gang" footprint. This footprint enables the product to be mounted flush, alone on an old style work box, new work box or SAE'S surface mount J t Gang Back Box (IGB). It must also be "gangable" up to 6 places to fit flush workboxes that can be screwed or ganged together or SAE's surface mount IGB boxes that come in 1 thru 6 gang sizes. All gmgmIt plates, sized 1 thru 6 gang shall be available in Red, White, Stainless or Yellow and may be placarded with a 1.5" x 3" custom plaque. . Space Age welcomes customization of the product line, if you require a large red mushroom type switch on a yellow place specially lettered for "Generator Shut Down" or a lighted push . button switch on a stainless steel plate for a conveyor belt activation, Space Age will be happy to accommodate you. Remember, we supply code compliant solutions, so we will not only take your custom order, we will check to see what the actual requirements are for the functionality you are looking for. SSU# Part # Description . • GP1R nfinity Gang Plate 1 Gang Red . GP2R nfinity Gang Plate 2 Gang Red GP3R nfinity Gang Plate 3 Gang Red GP4R nfinity Gang Plate 4 Gang Red GP5R nfinity Gang Plate 5 Gang Red GP6R nfinity Gang Plate 6 Gang Red. GP1W nfinity Gang. Plate 1 Gang White • = = j GP2W nfinity Gang Plate 2 Gang White 11 111111; _ti : II l; 1! 1 .I GP3W nfinity Gang Plate 3 Gang White I GP4W - nfinity Gang Plate 4 Gang White • . irr= • • GP5W nfinity Gang Plate 4 Gang White 11,' 11 f J1 1 . J ' GP6W nfinity Gang Plate 6 Gang.White . GP1SS nfinity Gang Plate 1.Gang Stainless Stee D1 1jLjLDL ` ! 11111 GP2SS nfinity Gang Plate 2 Gang Stainless Stee GP3SS nfinity Gang Plate 3 Gang Stainless Stee GP4SS nfinity Gang Plate 4 Gang Stainless Stee GP5SS nfinity Gang Plate 5 Gang Stainless Stee GP6SS nfinity Gang Plate 6 Gang Stainless Stee GP1Y nfinity Gang Plate 1 Gang Yellow GP2Y nfinity Gang Plate 2 Gang Yellow GP3Y nfinity Gang Plate 3 Gang Yellow • GP4Y nfinity Gang Plate 4 Gang Yellow GP5Y . nfinity Gang Plate 5 Gang Yellow . GP6Y nfinity Gang Plate 6 Gang Yellow AI i Space Age Electronics, Inc. Agenc Approvals: www.isae.com QCIT.E36078 Metallic Outlet boxes 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax This document is subject to change without notice, see doc # ED0479 for legal disclaimer • No Excuses, .lust Solutions! ED0432 LT10441 Rev.A 2/2 INSTALLATION AND MAINTENANCE INSTRUCTIONS *Th, S� STEM � SENSOR® R- 10E /R- 20E /R- 14E /R -24E 3825 Ohio Avenue, St. Charles, Illinois 60174 1- 800- SENSOR2, FAX: 630 - 377 -6495 Multi Voltage Relay www.systemsensor.com Specifications Operating Voltage: 18- 35VDC, 18- 35VAC, 115VAC, 230VAC Operating Current (R- 10E /R14E): 23mA DC @ 24V, 59mA AC @ 24VAC; 150mA AC @ 120VAC, 180mA AC @ 240VAC Operating Current (R- 20E /R -24E): 40mA DC @ 24V, 92mA AC @ 24VAC; 220 mA AC @ 120VAC, 260mA AC @ 240VAC Operating Temperature: -40 °F to 158 °F ( -40 °C to 70 °C) Humidity Range: 10% - 85% non - condensing Dimensions: R- 10E /R -20E: 3.7 "H x 5.3 "W x 2.7 "D (94 mm H x 135 mm W x 69 mm D) R -14E /R -24E: 5.4 "H x 10.9 "W x 2.7 "D (137 mm H x 277 mm W x 69 mm D) Accessories: R- 10E /R -20E - 2 mounting screws R -14E /R -24E - 4 mounting screws Contact Ratings: 24VDC 7A 120VAC 10A 120VAC 1 /6 HP 230VAC 7A Notice: This manual should be left with the owner /user of this equipment. - General Description Models R- 10E /R -20E and R -14E /R -24E are multi voltage The R -10E is a single 1 FORM C (SPDT) relay with a red relays with terminal strip field wiring connections, mount- LED and the R -14E is a 4 -gang 1 FORM C (SPDT) relay with ing track and hardware mounted in a steel enclosure. The 4 red LEDs. The R -20E is a single 2 Form C (DPDT) relay closure has a removable front cover that provides easy with a red LED and the R -24E is a 4 -gang 2 Form C (DPDT) access and a LED viewing hole on the top of the cover. relay with 4 red LEDs. The LEDs indicate the energization of the Relay Coil. Non -Power Power Limited Limited - ��. II — 4111 ._•�1111. ± IN ■ , -.. , p _,.. H __,,, - - I O S . • - . - J vm-- - . -• 9) tea— I -sE2+ 4:ins. - -E13-- c am' -1B- / � \ 0 1 - i.■ ,■, i.. v \ \ 0 var.: , : a a l 1 ► , , , ■ r t ii I r► .e O \ mi l / � i�� 1�� 'rte Q ` 0 �� Iris , .....e , .....e ( m C3 =1 \ \ \ \V \ Iduvoc,.iw an m,wnc 1 zwc +..rv.c nW.0 . MA. 00569 -01 D 00567.01 CO527 -01 Metal Enclosure R -10E Relay R -20E Relay D500 -82 -00 1 156- 2536 -02 • • • • • • • • • • • • • Three -Year limited Warranty System Sensor warrants its enclosed relay to be free from defects in mate- 3825 Ohio Avenue, St. Charles, IL 60174. Please include a note describing rials and workmanship under normal use and service for a period of three the malfunction and suspected cause of failure. The Company shall not years from date of manufacture. System Sensor makes no other express be obligated to repair or replace units which are found to be defective warranty for this relay. No agent, representative, dealer, or employee of because of damage, unreasonable use, modifications, or alterations occur - the Company has the authority to increase or alter the obligations or limi- ring after the date of manufacture. In no case shall the Company be liable tattons of this Warranty. The Company's obligation of this Warranty shall for any consequential or incidental damages for breach of this or any be limited to the repair or replacement of any part of the relay which is other Warranty, expressed or implied whatsoever, even if the loss or dam - found to be defective in materials or workmanship under normal use and age is caused by the Company's negligence or fault. Some states do not service during the three' year period commencing with the date of manu- allow the exclusion or limitation of incidental or consequential damages, facture. After phoning System Sensor's toll free number 800- SENSOR2 so the above limitation or exclusion may not apply to you. This Warranty (736 -7672) for a Return Authorization number, send defective units gives you specific legal rights, and you may also have other rights which postage prepaid to: System Sensor, Repair Department, RA # , vary from state to state. D500 -82 -00 2 156- 2536 -02 0 2004 System Sensor Submit by Email I Sealed Lead Acid Absorbed Glass Mat Werker. Technical Specifications WKAl2-7.5F Discharge Characteristics Duration of Discharge @ 77 °F 132V 1 nov `� �� \ d _ 114V � . O 10 l 0 76A 0.36A 6.4 0w i t 7.4A 1611 Wer xer: 7., 1 2 6 6 6 10 70 60 60 2 6 6 310 20 60 I-- min hr I AU ,t2.. �A srIn'ciO Discharge Time ,vim SS Discharge Duration vs. Discharge Current Duration of Discharge @ Various Temperatures 2CA `: ° C 100 \ \ m � \ 1 04°F m 3A 32 °F � �� 77 °F Specifications 1A \ ��� All Specifications Are Rated at 77 °F Unless Otherwise Noted 5'F \� Nominal Voltage 12V 300ma .� Ampere Hour Capacity (20hr Rate to 1.75VPC) 7.5Ah 1 inches millimeters 3 5 10 20 40 60 2 4 6 10 15 2030 I min hr Length 5.95" 151 ±1mm Dimensions Width 2.56" 65 ±1mm Discharge Time Height 3.70" 94 ±1mm Height w/Term. 3.94" 100±1 mm Wight 5.60Ibs Capacity Ratings Case Plastic ABS Resin 20 hour rate 7.50AH Maximum Charge Current 0.3C or 2.25A Capacity 10 hour rate 7.00AH Float Use Voltage 2.28V /Cell @ 77 °F 5 hour rate 6.40AH Recommended Float Use Current <1.1A 1 hour rate 4.65AH Charging Cycle Use Voltage 2.45V /Cell Cycle Use Current <2A 1 Month 97% Wattage Ratings Shelf Life 2 Months 91% End Voltage 3 Months 83% Discharge Rate 1.75V /Cell 1.67V /Cell Charge 32 °F to 104 °F 5 min. rate 54.1 55.9 Temperature Discharge 5 °F to 122 °F 10 min. rate 36.5 37 7 Range Storage 5 °F to 104 °F 15 min. rate 27.8 28.7 Capacity Affected 104 °F 103% 30 min. rate 16.9 17.4 by Temperature 77 °F 100% 45 min. rate 10.9 10.4 (20hr rate) 32°F 86% 60 min. rate 9.8 10.2 The information contained on this specification is generally descriptive only and is not intended Ascent Battery Supply LLC to make or imply any representation guarantee or warranty with respect to any cells and 925 Walnut Ridge Drive batteries Cell and battery design/specrfication are subject to modification without notice. Hartland, WI 53029 Iii page 1 of 2 • • ' . . . . , . . . . . . . . . . . . . • . . • . . . , . . . . . rker. Sealed Lead Acid Absorbed Glass Mat We Technical Specifications . . ., WKAl2-7.5F . . . Cycle Life vs. Depth of Discharge -. Physical Dimensions 120% • , A L.,,.._ e ---.. 100 • I I . .---• I I 1 is a• 60% - _I C D 100% 50% SO% . . 1 _ I f./ Depth al Depth te 1 4096 ._ 0 7 1 ......._._.„ , 1 Depth ce Discreepe 1 ,• 20% 0 200 400 600 800 1000 1200 1400 • i in Charge/Discharge Cycles IIIIPIE A 1 590 151 • e B 2_56 65 C 3.70. 95 1; • 0 3 98 101 '' ' • Effect of Temperature on Float Life • . . • io • , Terminal . . I 5 • I in I mm 3 • j i:1 [ • A 0 1 46:7305 CI . —...-tr..-- C 0.031 I 0.79 >- • . 1 B C at . • ..1 1 .• , . a) .• '.- 1 • . • u . . • • • .. _ • • 5 . . Open Circuit Voltage vs. Capacity . O . .. Estimated Residual Capacity @ 77°F . _ . • 0.3 1 • 14.0V 13.5V -I 1 I I g 1 I jo, 13.0V I 1 1 - 0150 68° 86° 104° 122° T 140 158° . i 1 I o 12.0V i • emperature (F°) 0 I I I I 10.5V I 1 I . NU . 10.0V . litli it asaisio■ . 0% 20% 40% 60% 80% 100% I C i : : Approximate Capacity (%) 0 kr . • • MH 20720 The information contained on this specification is generally descriptive only and is not intended Ascent Battery Supply LLC to make or imply any representation guarantee or warranty with respect to any cells and 925 Walnut Ridge Drive 9 batteries. Cell and battery design/specification are subject to modification without notice. Hartland. WI 53029 ni page 2 of 2 . . SHP PRO Battery Calculation Form Version 3.1 1- May -08 Back Up Hours required: [24, 60 or 90 Hours (FM Only)] Normal Operation: Controller Current 0.135 A Auxiliary Output Current: 0.080 A Total Normal Current = 0.215 X 24 0 hours = 5.16 A -H Alarm Operation: Controller Current: 0.135 A CRM4 [Number of relays modules installed] 1 0.040 A Output Device Current: 0.148 A Auxiliary Output Current: A 0.198 Total Alarm Current = 0.521 X 5 minutes = 0.0432 A -H Total A -H used = 5.2032 A -H (X1.2 tactor) Must ceed I Total Power Required -> 6.2439 A -H Power Supplied: Controller Supplied Current: 4.135 A Auxiliary In Current 0.060 A Total Current Supplied = 4.195 Amps Total Battery Pack A -H Available (7 or 18 A -H) 7 A -H SHP PRO Battery Calculation Form Back Up Hours required. [24, 60 or 90 Hours (FM Only)] Normal Operation: Controller Current 0.135 A Auxiliary Output Current. 10 A Total Normal Current = 0.235 X 24 hours = 5.64 A -H Alarm Operation: Controller Current. 0 135 A CRM4 [Number of relay modules installed] 2 0.080 A Output Device Current: 1.00 A Auxiliary Output Current. 0.10 A Total Alarm Current= 1.32 X 0.083 hours = 0.109 A -H Total A -H used = 5 749 A -H (X1.1 factor) Vlr>iIMZ= Total Power Required - --> 6 32 A -H Power Supplied: 'I N N • Controller Supplied Current 4 135 A Auxiliary In Current A Total Current Supplied = 4.135 Amps Total Battery Pack A -H Available (7 or 18 A -H) 7 A -H NAC Circuit LoadNoltage Drop Calculations Date: 9/28/2010 Job Number: 608S Job Name: ACS - 2nd Fl. LAN Room NAC Circuit: NAC -1 Device Type I Qty. I Amps I Total Space Age Module A/V devices I I IAVHORN - LOW 1 0.003 0.003 IAVHORN - HIGH 0.025 0.000 IAVSLM24 - Steady incand. 2 0.096 0.192 IAVFLM24 - Flashing incand. 0.050 0.000 IAVSTR24 - Strobe 0.115 0.000 I 0.000 0.000 0.000 0.000 0.000 0.000 • 0.000 0.000 1 I 0.000 0.000 0.000 0.000 0.000 I 0.000 I I 0.000 0.000 0.000 I 0.000 0 000 0.000 0.000 0.000 0.000 Combined Device Totals 3 0.195 Voltage Drop - Wire Size (One Way Distance) I Feet I Resistance I Drop AWG 16 - 5.29 Ohms /1000 ft I I 0.000 I 0.000 AWG 14 - 3.26 Ohms /1000 ft 40 0.051 0.076 AWG 12 - 2.05 Ohms /1000 ft I I 0.000 I 0 000 • • . F ORPORATION E- Squared Systems 10111 S. Tacoma Way Suite D-6 • • Lakewood, WA. 98499 Phone: 253 - 274 -3707 Fike HFC -227ea FlowCalc FIK3.02 UL: EX4623 FM: 0Y4A8.AF • • Project: ACS File Name: 608S.FLC Consolidated Report Customer Information Company Name: E- SQUARED SYSTEMS Address:. LAKEWOOD, WA. • Phone: 253 - 284 -3707' Contact: CHRIS SWANN Title: Project Data • Project Name: ACS Designer: KB Number. 608S • Account: C1 • • Location: 2ND FL. LAN ROOM • Description: • . . • . • • • Page: 1 of 7 Calculation Date/Time: Tuesday, September 28, 2010, 10:24:46 AM Copyright (c) Hughes Associates, Inc. Licensed to: Fike Protection Systems • • • Pike . Consolidated Report • Enclosure Information Elevation: 100 ft (relative to sea level) • Atmospheric Correction Factor: 1 Enclosure Number. 1 Name: LAN ROOM Enclosure Temperature... • Minimum: 68 F . Maximum: 72 F Maximum Concentration: 7.462 % • Design Concentration... Adjusted: - 7.404 % • Minimum: • • 6.250•%, . • Minimum Agent Required: 120.9:Ibs • . • Width: 21.6 ft. Length:, 20.5 ft Height: 9.0 ft • Volume:. 3985.2 cubic ft Non- permeable: 0.0 cubic Total Volume: 3985.2 cubic ft Adjusted Agent Required: 145.0 lbs Number of Nozzles: 1 • • • • • • • • • Page: 2 of 7 Calculation Date/Time: Tuesday, September 28, 2010, 10:24:46 AM Copyright (c) Hughes Associates, Inc. Licensed to: Fike Protection Systems Fik e Consolidated Report Agent Information • Agent: HFC -227ea / Propellant N2 Adjusted Agent Required: 145.0 lbs Cylinder Name: 150 lb. Cylinder, Upright Cylinder Part Number: 70 -267 Number of Main Cylinders: 1 Number of Reserve Cylinders: 0 Manifold: No Manifold Pipe Take Off Direction: Up Agent Per Cylinder: 145.0 lbs Fill Density: 67.3 lbs / cubic ft Cylinder Empty Weight: 150.0 lbs Weight, All Cylinders + Agent: 295.0 lbs Floor Area Per Cylinder. 2.18 square ft Floor Loading Per Cylinder: 135 lbs / square ft Pipe Network Part 1 - Pipe Pipe Description Start End Type Diameter Length Elevation Main Cyl.X1 0 1 3 i 1.97 ft 1.97 ft Pipe 1 2 40V 1 -1/2 in 0.50 ft 0.50 ft Pipe 2 3 40V 1 -1/2 in 1.00 ft 0.00 ft Pipe 3 4 40V 1 -1/2 in 7.25 ft 7.25 ft Pipe 4 5 40V 1 -1/2 in 5.50 ft 0.00 ft Pipe 5 6 40V 1 -1/2 in 1.50 ft 0.00 ft - Pipe /E1 -N1 6 7 40T 1 -1/2 in 1.00 ft -1.00 ft Part 2 - Equivalent Length Start End 90 45 Thru Side Union Other Added Total 0 1 0 0 0 0 0 0.00 ft 30.9 ft Page: 3 of 7 Calculation Date/Time: Tuesday, September 28, 2010, 10:24:46 AM Copyright (c) Hughes Associates, Inc. Licensed to: Fike Protection Systems • • • • . like Consolidated Report , Part 2 -. Equivalent Length • Start End 90 45 Thru Side Union Other Added Total . . 1 2 0 0 0 0 0 0.00 ft 0.5 ft 2 3 1 0 0 0 0 0.00 ft 3.6 ft 3 -. 4 1 0 0 0 0 0.00 ft 9.9 ft 4 5 1 o 0 0 0 o.00 ft 8.1 ft 5 6 . 1 0 0 0 0 0.00 ft 4.1 ft . • 6 7 1 0 0 0 0 0.00 ft 5.3 ft ; • • . • Part.3 - Noizles • ' Start - End Flow Name Size Type Nozzle Area 0 1 145.0 lbs 1 2 145.0 lbs 2 3 145.O lbs 3 4 145.0 lbs • 4 5 145.0 lbs • 5 6 145.0 lbs • 6 7 145.0 lbs El-N1 1-1/2 in 180 Degree 0.6392 square in • Parts Information • Total,Agent,Required: 145.0 lbs Cylinder Name: 150 lb. Cylinder, Upright (Part: 70-267) Number Of Cylinders: 1 Field1 Nozzle Type Diameter Nozzle.Area Part Number El-N1 180 Degree 1-1/2 in 0.6392 square in 80-065-2720 • Nozzle Drill Diameter Drill Size El-N1 0.2720 inches Pipe: Type Diameter Length 40T 1-1/2 in 1.00 ft 40V 1-1/2 in 15.75 ft Page: 4 of 7 Calculation Date/Time: Tuesday, September 28, 2010, 10:24:46 AM Copyright (c) Hughes Associates, Inc. Licensed to: Fike Protection Systems - • • pike. • . Consolidated Report List of 90 degree elbows: •5- 1 -1 /2in • • System Acceptance WARNING - The data in this project may have been changed after the calculations were performed. • System Discharge Time: 9.4 seconds Percent Agent In Pipe: 14.3% Percent Agent Before First Tee: 0.0% Enclosure Number: 1 Enclosure Name: ` LAN ROOM Minimum Design Concentration: 6.250% . • 'Adjusted Design Concentration: 7.404 %' Predicted Concentration: 7.405% ' • - Maximum Expected Agent Concentration: 7.462% (At 72 F) • Minimum - Adjusted - Predicted Nozzle Agent . Agent Agent Pressure Nozzle Required Required Delivered (Average) E1 -N1' 120.9 lbs 145.0 lbs 145.0 lbs 144 psig • • • • • r. • • • Page: 5 of 7 Calculation Date/Time: Tuesday, September 28, 2010, 10:24:46 AM Copyright (c) Hughes Associates, Inc. Licensed to: Fike Protection Systems • • • • • • like' Con Report - r Drawing View: 1 _ • • • • • • • • • 1 -N1 1 X 150 Ib. Cy i r; Upright:- No Manifold W s Drawing View: 5 • • • • • • W `' '4 1 150 I•. Cylinder, Upright - No Manifold • E1 -N1 Page: 6 of 7 Calculation Date/Time: Tuesday, September 28, 2010, 10:24:46 AM Copyright (c) Hughes Associates, Inc. Licensed to: Fike Protection Systems like Consolidated Report Drawing View: 9 r E1 -N1 3 W E • . - 1 X 150 Ib. Cylinder, Upright - No Manifold 6 • • • n Page: 7of7 Calculation Date/Time: Tuesday, September 28, 2010, 10:24:46 AM • Copyright (c) Hughes Associates, Inc. Licensed to: Fike Protection Systems •