Loading...
Plans q 700 i'/V aA) ` , S Rd F P5 20 j c - oao I • Bulletin 136 Rev .O CO • Model F1FR 1 . Reliabld Model F1FR Recessed 5 Quick Response Sprinklers o Model F1 FR Sprinkler Types Standard Upright Standard Pendent RECFIVED ti , , , Conventional °' Vertical Sidewall . i Horizontal Sidewall FEB 0 52 010 . - HSW 1 Deflector CITY OF TIGARD 1 Model F1 FR Recessed Sprinll - VISIC N Recessed Pendent Recessed Horizontal Sidewall Upright Pendent - HSW 1 Deflector Listings & Approvals t 1. Listed by Underwriters Laboratories, Inc. (UL) fl 0 2. Listed by Underwriters' Laboratories of Canada (ULC) 3. Certified by FM Approvals 4. Loss Prevention Council (LPC, UK) ____ 5. NYC BS &A No. 587 -75 -SA 6. Meets MIL- S -901C and MIL -STD 167 -1 '.. 7. Verband der Schadenversicherer (VdS, Germany) f 8. NYC MEA 258 -93 -E • UL Listing Category Vertical Sidewall Conventional Sprinklers, Automatic & Open Quick Response Sprinkler UL Guide Number -- . VNIV tif1110 - . i. fit f - , . 1 I Patents: US Patent No. 6,374,920 Applies to , - Model F1 FR Vertical Sidewall Sprinklers. - Product Description Horizontal Sidewall Recessed Pendent Reliable Models F1 FR and F1FR Recessed Sprinklers are HSW 1 Deflector (Model FP Shown) quick response sprinklers which combine the durability of a pands, forcing the bubble smaller and smaller as the liquid standard sprinkler with the attractive low profile of a decorative pressure increases. Continued heating forces the liquid to sprinkler. push out against the bulb, causing the glass to shatter, The Models F1FR and F1FR Recessed automatic sprinklers opening the waterway and allowing the deflector to d istrib- utilize a 3.0 mm frangible glass bulb. These sprinklers have ute the discharging water. demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This Application quick response enables the Model F1 FR and F1FR Recessed Quick response sprinklers are used in fixed fire protec- sprinklers to apply water to a fire much faster than standard tion systems: Wet, Dry, Deluge or Preaction. Care must be sprinklers of the same temperature rating. exercised that the orifice size, temperature rating, deflector The glass bulb consists of an accurately controlled amount style and sprinkler type are in accordance with the latest of special fluid hermetically sealed inside a precisely manu- published standards of the National Fire Protection Asso- factured glass capsule. This glass bulb is specially con- ciation or the approving Authority Having Jurisdiction. structed to provide fast thermal response. The balance of Quick response sprinklers are intended for installation as parts are made of brass, copper and beryllium nickel. specified in NFPA 13, FM Global Loss Prevention Data At normal temperatures, the glass bulb contains the fluid Sheet 2 -8N or other applicable standards. Quick response in both the liquid and vapor phases. The vapor phase can sprinklers and standard response sprinklers should not be be seen as a small bubble. As heat is applied, the liquid ex- intermixed. The Reliable Automatic Sprinkler Co., Inc. 103 Fairview Park Drive, Elmsford, New York 10523 , 4 y Model F1 FR Quick Response Upright, Pendent & Conventional Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: . K Factor Sprinkler Identification Sprinkler Type Sprinkler Approval Number (SIN) US Metric Height Organization SSU SSP • Standard- Upright (SSU) and Pendent (SSP) Deflectors Marked to Indicate Position }2" (15mm) Standard Orifice with y," NPT (R)2) Thread 5.6 80 2.2" (56mm) 1,2,3,45,6,7 R3625 R3615 'X; (20mm) Large Orifice with yr NPT (R 8.0 115 2.3" (58mm) 1,2,3,4,7,8 R3622 R3612 y,, (17mm) Small Orifice with y" NPT (RX) Thread 4.2 60 2.2" (56mm) 1,2,8 83623 R3613 %" (1 0mm) Small Orifice with y," NPT (R)2) Thread 2.8 40 2.2" (56mm) 1,2,8 R3621 R3611 10mm Orifice XLH with R9" Thread 4.2 60 56mm 4,6,7 R3624 R3614 Conventional - Install in Upright or Pendent Position 10mm Orifice XLH with R% Thread 4.2 60 56mm R3674 15mm Standard Orifice with NPT (R)z) Thread 5.6 80 56mm - 4,6,7 R3675 20mm Large Orifice with 3 /4" NPT (R 8.0 115 58mm 4,7 R3672 t Polyester coated upright UL and ULC listed corrosion resistant r • r _ iijiiiiii"*. •••• • .- Upright Pendent Conventional Model F1 FR Quick Response Recessed Pendent Sprinkler Installation Wrench: Model GFR1 Sprinkler Wrench Installation Data: Nominal Thread K Factor Sprinkler 1 Approval Sprinkler Identification Orifice Size US Metric Height Organizations Number (SIN) . y;" (15mm) )'," NPT (R1/2) 5.6 80 2.2' (56mm) 1,2,3,4,5,7,8 R3615 1 %2" (20mm) y," NPT (R 8.0 115 2.3" (58mm) 1,2,3,8 R3612 T ,s' (1 1mm) y" NPT (R'/2) 4.2 60 2.2' (56mm) 1,2,8 R3613 %" (10mm) )2" NPT (R1/2) 2.8 40 2.2' (56mm) 1,2,8 R3611 10mm RYE' 4.2 60 56mm 4,7 R3614 (1) Refer to escutcheon data table for approvals and dimensions. �_ 2 1/4' HOLE OI 2 5 /8" DIAL [66.7mm] (572mmJ HOLE IN CEILING 1 15/16' 0IA _...j •Mi 014 2 5/16' DIA. (58.7mm] .".— 1 CUP r 1' X t/?' REDUCE 1 1' X 1/2' REDUCER IURN COLLAR C UNTIL TIGHT AGAINST SPRINKLER WRENCH 8D55 \ I ,II,'4 1 , 1 9 L J T V ■ d w FACE OF FITTING TO CEILING i (t 1 rz , CEILING DIMENSION ����I� ADJUSTMENT a �.� ,,,, 1 I F( FACE OF FITTING } I I/8 , 1 1 - 1011). TO FACE OF CEILING L 1 DIMENSION 0) I f (3.2mm] A � .(q � ,\ 1% %% _ I r 2 27/3r OK l (1 � __ ill 4. A•!17 (72.2mm] 1 36FCO1_E ADJUSTMENT t 136FG05_A (1) REFER TO Fl & F2 ESCUTCHEON DATA TABLE FOR APPROVALS AND DNIENSIONS. 4 (1] REFER TO FP ESCUTCHEON DATA TABLE FOR APPROVALS AND DIMENSIONS. 2. , Model F1 FR Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: Nominal Thread K Factor Sprinkler Approval Sprinkler • Orifice Size US Metric Height Organizations Number (SIN) (SIN) /" 1/2" NPT (R1/2) 5.6 80 2.2" (56mm) 1, 2, 3, 6, 8 R3685 15mm 1/2" NPT (R1) 5.6 80 2.2" (56mm) 4 (1) (1) LPC Approval is for Pendent position only. Orientation Deflector to Ceiling Dimension (Min. - Max.) Upright 4" - 12" (102mm - 305mm) l i i iiii Pendent 6" - 12" (152mm - 305mm) Vertical Sidewall US Patent No. 6,374,920 Model F1 FR Quick Response Horizontal Sidewall Sprinkler Deflector: HSW 1 Installation Wrench: Model D Sprinkler Wrench Installation Data: Approval Organizations K Factor and Type of Approval Sprinkler Nominal Thread Sprinkler Identification Orifice Size US Metric Length Light Ordinary Number (SIN) Hazard Hazard }z" (15mm) }z" NPT(R'/) 5.6 80 2.63" (67mm) 1,2,3,5,8 1,2,5,8 R3635 NOTE: UL, ULC and MEA Listing permits use with F1 or F2 recessed escutcheon. FM Approvals do not permit recessed usage. 136FG04 r 4 or d/ / ;;1 ry 0) FACE OF FITTING TO WALL DIMENSION ., 1 1/4" MIN. i(f+t ,� [31.8mm] g ' 2 1/4 HOLE DIA. 1/8 4 ^_g^ (57.2mm] (3.2mm] [101.6mm- 152.4mmj 1" X 1/2" REDUCER DEFLECTOR A — : r.- ---: -/--- I& I d i r\-,Nw : '' .--r1 1 15/16" DIA. 12" I :. ■ j1- I Horizontal Sidewall 149.2mm] , mu -- i„ :11�r a l;l 2 27/32" DIA. 1 ,� � �_` r ,_. ' [72.2mm) TURN COLLAR UNTIL \ A GHT AGAINS SP RI NK L E R \ \`! WTI RENCH BOS S. ■ ADJUSTMENT 1 (1 ) REFER TO ESCUTHCEON DATA TABLE FOR APPROVALS AND DIMENSIONS. 3. • Installation Quick response sprinklers are intended for installation as tle vacuuming. Remove any sprinkler which has been specified in NFPA 13, FM Global Loss Prevention Data Sheet painted (other than factory applied) or damaged in any 2 -8N or other applicable standards. Quick response sprin- way. A stock of spare sprinklers should be maintained to klers and standard response sprinklers should not be inter- allow quick replacement of damaged or operated sprin- mixed. klers. Prior to installation, sprinklers should be maintained The Model F1 FR Recessed Quick Response Sprinklers are to in the original cartons and packaging until used to mini - be installed as shown. The Model F1 or F2 Escutcheons illus- mize the potential for damage to sprinklers that would trated are the only recessed escutcheons to be used with the cause improper operation or non - operation. Model F1FR Sprinklers. The use of any other recessed escutch- eon will void all approvals and negate all warranties. Sprinkler Types When installing Model F1FR Sprinklers, use the Model D Sprin- Standard Upright kler Wrench. When installing Model F1FR Recessed Pendent or Standard Pendent Sidewall Sprinklers, use the Model GFR1 Sprinkler Wrench. Any Conventional other type of wrench may damage these sprinklers. Sidewall (Vertical, Horizontal HSW1) Glass bulb sprinklers have orange bulb protectors to minimize Recessed Pendent bulb damage during shipping, handling and installation. RE- Recessed Horizontal Sidewall HSW1 MOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Re- Finishes n) (2' moval of the protectors before this time may leave the bulb vul- Standard Finishes nerable to damage. RASCO wrenches are designed to install Sprinlder Escutcheon sprinklers when covers are in place. REMOVE PROTECTORS Bronze Brass BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS Chrome Plated Chrome Plated (3) TO REMOVE THE PROTECTORS. White Polyester Coated White Painted (3) Temperature Ratings Special Application Finishes Sprinkler Sprinkler Escutcheon Classification Temperature Max. Ambient Bulb °C °F Temp. Color Bright Brass Bright Brass Black Plated Black Plated Ordinary 57 135 100°F (38°C) Orange Black Paint Black Paint Ordinary 68 155 100F(38°C) Red Intermediate 79 175 150°F (66°C) Yellow Off White Off White Intermediate 93 200 150°F(66°C) Green Satin Chrome Satin Chrome High (11 141 286 225°F (107°C) Blue (1) Other finishes and colors are available on special order. (1) Not available for recessed sprinklers. Consult the factory for details. Escutcheon Data (2) FM Approvals is limited to bronze and brass, chrome or black plated finishes only. Escutcheon " FacedFMInp ( FP Push - on/Thread -off escutcheon. Model Approvals A4rralmem Oirnertsbn b Wing at ( UL and ULC listed corrosion resistance. Vial Menke SIN numbers: R3621, R3622, R3623, R3625. I . Max Recess (38. m) a '� s Note: For y" orifice pendent FM approved white F1 1,2,4,8 Min Recess X" (5mm- 24rrrn) polyester coated and UL approved white polyester , (19.1mm) corrosion resistant sprinklers refer to Bulletin 014. 1y „ F2 1,2,30),4,5,7,8 Max Recess (38.1mm) '/,e °- 'X." Ordering Information Min Recess ,! " (5mm -17mm) Specify: (24mm) 1. Sprinkler Model FP 1,2 Max Re- X6" 1y" (38.1mm) Push -on/ cessed (11mm) 2. Sprinkler Type Thread-off 1,2 Min Recessed '' 1 "(254mm) 3. Orifice Size (24mm) 4. Deflector Type No Dimensional Figure for FP 5. Temperature Rating I (1) Horizontal Sidewall is not FM approved in the reccesed configuration. 6. Sprinkler Finish Maintenance 7. Escutcheon Type The Models F1FR and F1FR Recessed Sprinklers 8. Escutcheon Finish (where applicable) should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean Note: When Model F1FR Recessed sprinklers are sprinklers with soap and water, ammonia or any other ordered, the sprinklers and escutcheons are packaged cleaning fluids. Remove dust by using a soft brush or gen separately. The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputa- ble sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by • The Reliable Automatic Sprinkler Co., Inc. ® Recycled ReIiabId (800)431 -1588 Sales Offices • (800)848-6051 Sales Fax Corporate Offices Revision lines indicate updated or new data (914)829 2042 www. reliablesprinkler.com Internet Address EG. Printed in U.S.A. 06/09 P/N9999970027 Flex Head commercial fire sprinkler connections , , v vemplorsii, ariapiillir -.. --s '• . ..„... . Ab.. .--....i....f.-.. ' ..-2,4„,-:,.. ,•,',.,,,,,-: , .. , ,,iiioni p„, IP . 1 • • , ..,:...,...,. ••• ,:•„: :'.1'..; . ..° . - -. " frr i k It • iariiislaiL . .... : . ... „ ,.....,,...„..-,,,, •,:.:- ....F s .,..,.. i . ,..! . . I vA '' . . .., ,....: - • . .. '...,. ...0i ...,.. • • 1 I FEB 0 5 i isissoo ' .. ,i...-:,.---.;.,,-,“ -.••,',;'....._ ...'r1= ,:.,,,,-, , 4 .„......, ,,,•,-„, i rwr„ t.:::3(r.! ,, • . I-Llik • 1 • -,-,--,, . 61001W, /. •-.:, ' 1 , , I 1 .N._ t,-.1*;' . .: '- , :.......N.8,-, , ..!, , 1 • . - :. o tif -:....:::.,.- -_,• ..1,,_ , __ .. .4:,,:2. . , :....4„„,_ ,...;;,.... • „ , „..„ • , ' - '...01.0.1kee r, .. .. . _ .. . • „,.,• .4,..& . . _ .. ., J „....._ .__ -._,._- • i • .,: . % ".... .. ,.. ! 4 , Ili " ..... "I ' ' , ••• ;:- ,i; ,:,'4. ' t 1 :;'.. .-1' ' .• ... , i , '!....,'• ;,' . ” ' - • ' ' - 4: A,L . ••1 :;r.,i•: ...-. . . . , - '..ii - ' , .''.':..4 - ..; . • • W i - , • ' 't ! •-••• ', - • .:,,,,,,:,!",.,:,?,, ',.> • •• . •,.-: . A •"'. i ' ,,,, , • ' 1 .18 , -' .., , . .-- .:. ( '. ir ....f. . .4.....• . - y...., ... .. ,, • • .. 41111/4 .1,.: '',.,..•..:,, . .. • ' • '.?, • .i oit— -' .„. . .... • . .... - --f, ,.. 4. . ,,...: .,......,:,.,, . ,. .....,4 ... •. • -,. •I . # ..- ' . 4 '''' .APialW'''''' , el . 10 . , ' N.- ...,:■:: ' iiii‘.1•17 . .,.....t.,.._„.,, :, ..„. -woo` ,.. • . . , LEXHEAD i N • Your connection to INDUSTRIES pp higher • • - - best idea in sprinkler systems sin - ater • - I I _i_ . • A And tower costs. 1. . (..' . . , MIIII- _______ ioo co. .. , , .. •...: 4„.: . ... . ._. A . aproWniginigult. APPROVED usup MP . t#1 , . N.Y.C. MEA #261-99-E CA: OPA-0672 F� Loss Data and S a r a FlexHead Outlet Hose Maximum FM /UL Maximum Maximum Maximum Rated Model # Size Assembly Number of Equivalent Length Ambient Pressure in(cm) Length 90- Degree Length of Temperature ft(m) Bends Schedule 40, Rating j (3 in. Nominal 1 in. F(C) d Bending Diameter Pipe, ft H- Series , Radius) FM /UL _ psi (kPa) /psi (kPa) t/1 2024, 202414 1/2(1.27) 2(0.6) 3 3.5/11 300°(148°) 175(1205)/300(2068) , O 2036, 2036H 1/2(1.27) 3(0.9) 3 4.8/16 300 °(148 °) 175(1205)/300(2068) I 2048, 2048H 1/2(1.27) 4(1.2) 4 6.8/24 300 °(148 °) 175(1205)/300(2068) e1 J 2060, 2060H 1/2(1.27) 5(1.5) 4 8.5/29 300 °(148 °) 175(1205)/300(2068) 2072, 207214 1/2(1.27) 6(1.8) 4 8.9/35 300 °(148 °) 175(1205)/300(2068) 1 2024, 2024H 3/4(1.90) 2(0.6) 3 7.8/12 300 °(148 °) 175(1205)/300(2068) {.1 2036, 2036H 3/4(1.90) 3(0.9) 3 8.1/18 300 0 (148 0 ) 175(1205)/300(2068) `, 2048, 2048H 3/4(1.90) 4(1.2) 4 - 17.9/23 300 °(148 °) 175(1205)/300(2068) i 2060, 2060H 3/4(1.90) 5(1.5) 4 19.9/29 - ` 300 °(148 °) 175(1205)/300(2068) .x{ 2072, 2072H 3/4(1.90) 6(1.8) 4 24.3/32 300 0 (148 0 ) 175(1205)/300(2068) I— L-) 2024E, 2024HE 1/2(1.27) 2(0.6) 3 _ 5.5/19 300 °(148 °) _ 175(1205)/300(2068) 2036E, 2036HE 1/2(1.27) _ 3(0.9) 3 - -- 6.8/23 300 °( 148 °) _ _ 175(1205)/300(2068) 2048E, 2048HE 1/2(1.27) 4(1.2) 4 _ 8.8/27 300 °(148 °) 175(1205)/300(2068) ,_ 2060E, 2060HE 1/2(1.27) 5(1.5) 4 10.5/32 300 °(148 °) 175(1205)/300(2068) 2072E, 2072HE 1/2(1.27) 6(1.8) 4 10.9/35 300 0 (148 0 ) 175(1205)/300(2068) 2024E, 2024HE 3/4(1.90) 2(0.6) 3 9.8/18 300 0 (148 0 ) 175(1205)/300(2068) o Y. 1 2036E, 2036HE 3/4(1.90) 3(0.9) 3 10.1/23 300 °(148 °) 175(1205)/300(2068) , a 2048E, 2048HE 3/4(1.90) — 4(1.2) 4 19.9/23 300 °(148 °) 175(1205)/300(2068) t 7 2060E, 2060HE 3/4(1.90) 5(1.5) 4 21.9/29 300 °(148 °) 175(1205)/300(2068) • 2072E, 2072HE 3 4 1.90 6 1.8) 4 26.3/32 300 °(148° ) 175 1205 /300(2068 Model plumbers: The ' ates high pressure unit ra i Qih psirg and the "1" designates ft (bow style urn '- ' M nexttead products are intended for use la hydraulically designed wt, pm - action, stele or dry pipe stni d ter C connections per NFPA 13, 13R, and 131/ guidelines. The hydraulic toss of the Etext4ead connector needs to be i ; included in the hydraulic design calculations the same as a vatve or fitting. Each Fle xHead sprinkkr' drop has ' a 3" minimum bend radius per IJL guidelines, and a 7" minimum bend radius per fly guidelines. * Equivalent Lengths are shown with maximum number of 90 degree bends at the minimum berm - radius. Different waves were obtained by Fat and UL due to the differences in mininutm bend radius, testing protocat and calculation methods. Please see individual testing standards for more information relative to friction w Loss (Equivalent Pipe) Pressure surges aren't a risk for FlexHead / , connection systems. Our fully braided rt. . ' stainless steel hose is rated to ' -*, 300 psi. " " / • „ � s Let FlexHead make your connection today. 1 ` :� 4 Am. _ i i elm Engineers Contractors Owners r +t..„ 0 Stainless steel quality Lower installation costs SIiorter' time to occupancy ... 4 o e,. , at black iron costs More productive installers Lower reconfiguration costs : �r... :: Fast -track construction No punch list items Cost effective code ea ; , 1, ` 'their compliance 4 a t _ industrial -grade Simp,i ified project Highest quality available r construction is mana ement Lower total cost N g More flexible scheduling of ownership ; ' .p , ` all - welded, with Cost- effective code Competitive advantage . " compliance ` for your $ company - * , f '° no 0-rings. Seismically qualified R :. ... � f i II e a { f0 1 s Connect sprinkler heads to sub- mains at least four times faster. FlexHead systems connect sprinkler heads to sprinkler sub -mains in about a quarter of the time it takes to ` install hard pipe. Add in the fact that less- skilled people can do the work, and you're looking at significant productivity gains. Expect even greater savings in retrofits, where Want pinpoint locations? No problem. FlexHead installs six to seven times faster than The design makes it easy to accurately locate hard pipe. sprinkler heads every time. If the spec calls for Everything about FLexHead says "fast installation." center -of -tile placement, you can do it with ease. You don't need to install bracing or hangers. There's In fact, you get center -of -tile placement every no on -site assembly. Every sprinkler connection is a install whether the spec calls for it or not. It takes finished, pre-constructed assembly, from the 1" pipe one more headache out of specifying and bidding. connector to the sprinkler head outlet. Accommodate floor plan changes. You pay a little more for FlexHead connections Need to relocate sprinkler heads? No problem. With compared to black iron armovers. But their tabor its built-in flexibility it's much easier to move heads savings far exceed the materials premium. to a new location to accommodate new layouts or Installation is simple uses of the space. It doesn't matter whether the sprinkler head is Retrofits in less time. semi- recessed, full pendant or fully concealed, it's a Need to comply to code in unsprinktered buildings? snap to attach to a FlexHead connection system. In contrast to costly and labor- intensive hard -pipe 0 Attach the bracket to t-bar ceiling grid. retrofits, FlexHead connections install in minutes in 0 Connect the FlexHead sprinkler drop to even the most restrictive spaces. the submain. Shorten your time to occupancy. 0 Secure sprinkler drop to the bracket. Faster installation times help get end -users into That's it! No more wasted hours spent hard - piping. No their spaces more quickly —and get installers on more frustration over changes to blueprints. No more their next projects faster. FlexHead connections • lost time fixing teaks and other problems common to virtually eliminate punch list items commonly hard -pipe armovers. found with hard -pipe armovers. Each connection is ready to install right out of the box. It comes complete with a mounting bracket— Green Benefits compatible with any suspended or Sheetrock ceiling system—and a one-piece, teak - tested FlexHead sprinkler drop. Three steps to faster installations. twit Attach bracket to t -bar ceiling grid Connect FlexHead sprin• r drop to submain. Secure FlexHead sprinkler drop to bracket. Connection also compatible with Sheetmck ceilings 0 5 y (0 0 1 1111.11V J i R y Elbow style unit used in confined space Adjustable Bracket Design: for use with T -bar applications. grid, metal stud and Chicago grid applications. FM approved and UL listed Fully guaranteed All FlexHead sprinkler connections are Factory FlexHead has always maintained a commitment to Mutual Approved and Underwriters Laboratories quality. We pressure- and leak -test every FlexHead listed for suspended or sheetrock ceiling connection at our FM- and UL- audited factory. Burst installations. Tests include hydrostatic pressure, pressures exceed 3,000 pounds. Every product is vibration, friction loss, fatigue, head deployment, covered by our comprehensive limited warranty. corrosion and water hammer. Choose the length you need Our commercial connections also conform to these FlexHead connections are available in 2', 3', 4', 5' and industry standards: 6' hose lengths, and easily fit any sprinkler head on Approved for use in suspended ceilings the market Outlets can accommodate both /." and - " with light, medium, and heavy -load grids sprinkler heads. (ASTM C -635 and C -636) Call, write or visit our website They're the only flexible sprinkler connection ' FlexHead Industries offers everything you need to qualified for use in Seismic Design Categories specify, bid and install higher quality fire protection. . C, D, E and F Let us make your connection today. Get in touch via International Building Code (IBC) compliant the method that suits you best: without needing an unsightly oversized ring, E -mail salesl @flexhead.com with questions and sleeve or adaptor where the ceiling meets the requests. sprinkler head Call toll -free 800 -829 -6975 to speak to a Compatible with BlazeMaster fire sprinkler representative. systems Visit www.flexhead.com for data sheets and Meets all NFPA 13 guidelines and is demonstrations. specifically referenced in the 2007 edition New construction comparison Retrofit comparison 0 0 0 0 0 0 1 , 4 FlexHeads ) 2 , z I V ' an -•ipe 1 Hard -Pipe I During a typical installation, a minimum of 4 During a typical installation, a minimum of 6 FlexHeads can be installed in the the same time it FlexHeads can be installed in the the same time it takes to do 1 hard -pipe. takes to do 1 hard -pipe. • • FlexHead metal stud detail • 11111111111'1'1'1', 1 —II 1 IIIicsig lllllltenw,„, i u i 111 u u 11 1 1.4101,1 ■ 'U1,1f11111t∎ 4001410, Sprinkler 4 1014114, Mont ' 'H111!! HIIlIIr 171...m..1...1....mil Flediead 044444 N,11111H Sprinkler Drop 1 (Ail 306 stainless ■ 1 1 steel including v ( fittings) r 1 i . Adjustable hub Metal stud I mounting bracket $ Al ..i♦ 1 in — -- Metal stud 1 411111111111111111111111111111 a Sheetrodr ceiling Sprinkler head (not included) d J ' ! exHead cusp = L( i ed ceiling detail ,.811111!l;111,1l1. ��IIIIIINNllllHII11!!I 1 rl'1'11111111!l11 /1111N►NU i� r'1 ►11111111 rl lllll1111i ' " 1111!1 N'' �1'1111141 Sprinkler 4100 H 41111111. branchtine P ' ?N111 FlexHead • ■II■IIN 111N1 Aut∎ Sprinkler Drop • MINI (AU 304 stainless 1 steel including 1 1 1 1 1 1 1 1 1 1 ! 1 1 fittings) Ma _tor Gelling grid ,_ mounting bracket Adjustable hub +-- i 1 111111111111 ,�, r' ; .. tSuspended rid ` = Ceiling the I "' � Sprinkl a A -a aR c Each FM approved, UL Listed, LPCB certified unit is ready -to- install, pressure- and teak - tested, and comes complete with a flexible . • stainless steel. hose and mounting bracket with adjustable hub. b. Flex Head commercial fire sprinkler connections Your secul . '.; i is our business , _ Ftex Head Industries was founded in 1992 to hell) engineers, builders and owners increase the safety of their buildings. Our Patented sprinkler connection technologies show that its possible to comply with codes W& re iNe re proud to help , .. )51 ' ‘ . -,.. ., P .. ., , reduce the risks of property damage a nd . - ... . , toss of life in a wide variety of liuildings, 4 +,•,,,,,.:, -4., .., , ., d omes ti ca it y an d wortrl-voide- .. 4, i :4 ) '''4 . ' \ ' • ' 4' ' '.1.'''''' 'i. Fleviieati rilanufactores o SI) titikter connections for a i _-\ ,;, c ll types of appbcatioris , , ,,-- i , 1 ; ' t _ 1 ' I - , . ' • 11,- i• 1 . inctuding: ,' ' 1 ,,,...,,....:._- ., ,.. . commercial, Exhaust ducts Institutions 4" r'ri Govenierit • Aerospace • Concrete penetratiorls 1 for sidewall and . itAls • Automotive • • Seisinlcally • HosP — Automotive apr)licatioris ,. , .' • offi • Biotechnology pendant . ' qUa " ed. • Restaurants • Electronics • Correctional centers Mental,. health facilities fti 1 r iridedperIcientctmoifemlaetnt ig fit Mental. __ _ _ _ _ exHea connections a • Retail • Forest products/ • Schoc)ls paper Pulf/ *I Lab°rat°rie between sub-rn crirrs and .,.. :-.1 Cleartroorns , -ceilings. They' the only • • Biotechnology Petrochemtcal . flexible sprinkler connection • Pharritacetiticats to be qualified for use in • Electronics seismic Destgn Categories ,1 • . • Restaurants • High-end commercial. ceilings • Semiconductors • Pharmaceuticals • St ee l irla • Semiconductors ... Y '‘‘ PUSTRI I-2 ,::) 7----. 4,,,,,Kur.astra-rim• ThC best idc'o. in spr, s r.' - 11,'a.,.. , ,tr.,ti ria!mlatitTruil pat t p151 .t IP:, 154 .. 4',Ii,119 7&4, 56 lowtand Stteet fti„.752,2:18, ti7 tr12 bit°, ttiv,,tgli,N'„ flottiston, Massacintsetts 01746 1 TU. flinHead 'o,) PAld Logo ata hartairoart, of fitaatizo.1 Lgida. ,r 9 in II 800 tfamtifEtiftr'S,y..solo totripatitt old .7,11tos I hit. otorluel ha‘ boao test tos ood r. Pi. +t On All OfigtAi bai,P, to assure ot erorat (508) 893 , 1 compatibility Kato no C-ot Ftaaotiaster', at• d COr7a gip, fax (508) 893 a id tittioas. info@ftexhead.com f GC/BM F[00(41:414 Ituitt'... Bia ood torzat, are r egistered troderoark or tiovroaa IP tWings Corp, iv vvvv.flexhead.com %I/SDP/03-09 [Page Too Large for OCR Processing] [Page Too Large for OCR Processing]