Loading...
Plans v Bulletin 136 Rev.L lite �• ® Model F1 FR c Model F1FR Recessed Imumilmommommininumo Quick Response Sprinklers I Model Fl FR Sprinlder Types Standard Upright Standard Pendent Conventional a 11 , Z = Vertical Sidewall o ° ir',p Horizontal Sidewall z` - HSW 1 r r o.."" 1 Def lector L1J 0 V j , : � � •4 Model Fl FR Recessed •, 'n :. ; , Recessed Pendent Ts Recessed Horizontal Sided r - HSW 1 Deflector Upright Pendent Listings & Approvals 1. Listed by Underwriters Laboratories, Inc. (UL) 2. Listed by Underwriters' Laboratories of Canada (ULC) ' _'` 3. Certified by FM Approvals provals , > — 4. Loss Prevention Council (LPC, UK) \ 5. NYC BS&A No. 587 -75 -SA r y' 6. Meets MIL- S -901C and MIL -STD 167 -1 7. Verband der Schadenversicherer (VdS Germ . � ..7. t - - ? 8. NYC MEA 258 -93-E UL Listing Category - f : • , Sprinklers, Automatic & Open Quick Response Sprinkler UL Guide Number Vertical Sidewall Conventional I VNIV • Product Description Reliable Models F1FR and F1FR Recessed Sprinklers are quick response sprinklers which combine the durability of a " • standard sprinkler with the attractive low profile of a decorative l�ii �' "' . -f sprinkler. �} v � !' a - z ' • The Models Fl FR and Fl FR Recessed l� i= �.. utilize a 3.0 mm frangible glass bulb. Theses p �be er rs have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model F1FR and F1FR Recessed Horizontal Deflector �� HSW 1 Deflector Recessed Pendent sprinklers to apply water to a fire much faster than standard sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount Application os pecial fluid hermetically sealed inside a precisely manufac- Quick response sprinklers are used in fixed ar us t be tured glass tion systems: Wet, D mt g capsule. This glass bulb is specially constructed to exercised that the orifice size, temperature rating, deflector provide fast thermal response. The balance of parts are made •' of brass, copper and beryllium nickel. style and sprinkler type are in accordance with the latest At normal temperatures, the glass bulb contains the fluid published standards of the National Fire Protection Asso- in both the liquid and vapor phases. The vapor phase can ciation or the approving Authority Having Jurisdiction. be seen as a small bubble. As heat is applied, the liquid ex- Quick response sprinklers are intended for installation as pands, forcing the bubble smaller and smaller as the liquid specified in NFPA 13. Quick response sprinklers and stan- pressure increases. Continued heating forces the liquid to card response sprinklers should not be intermixed. push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. The temperature rating of the sprinkler is identified by the color of the glass bulb. The Reliable Automatic Sprinkler Co., Inc. 525 North MacQuesten Parkway, Mount Vernon, New York 10552 Model Fl FR Quick Response Upright, Pendent & Conventional Sprinklers Installation Wrench: Model D Sprinkler Wrench . Installation Data: Standard - Upri (SSU) an Pendent (SSP) K Factor Sprinkler Approval Sprinkler Deflectors Marked to Indicate Position US Metric Height Organization SSU SSP y" (15mm) Standard Orifice with y" NPT R Thread 5.6 80 2.2" (56rrvn) 12,3,4,5,6,7 R3625 R3615 , 4 8.0 115 2.3" (58, nu) 1,2,3,4,7,8 R3622 R3612 4.2 60 2.54 "(65mm) 1,2,8 R3623 R3613 tom_ \-• - - AI Illiiiiiiiimms 2.8 40 2.54 "(65mm) 1,2,8 R3621 R3611 4.2 60 56.1mm 4,6,7 R3624 R3614 Conventional - Install in Upright or Pendent Position 10mm Orifice XLH with R% Thread 4.2 60 56.1 mm — R3674 15mm Standard Orifice with y" NPT (Ry) Thread 5.6 80 56.1mm 4,6,7 R3675 20mm Large Orifice with 3 A" NPT (R 8.0 115 _ 58.4mm 4,7 R3672 t A s 1 . . .. X -. l't [ lip, i' �� l C i i a 1 ' � Upright Pendent Upright Conventional Model Fl FR Quick Response Recessed Pendent Sprinkler Installation Wrench: Model RC1 Sprinkler Wrench Installation Data: Sprinkler Nominal Thread K Factor P Approval Sprinkler Identification Orifice Size US Metric Height Organizations Number (SIN) . Yz" (15mm) y" NPT (R') 5.6 80 2.2" (56mrn) 1,2,3,4,5,7,8 R3615 Mk. , -T 8.0 115 2.3" (58mm) 1,2,3 R3612 ......, 1 . 1 1 11 11Piiiii. 4.2 60 2.54" (65mm) 1,2,8 R3613 2.8 40 2.54" (65mm) 1,2,8 R3611 10mm RY 4.2 60 56.1mm 4,7 R3614 (1) Refer to escutcheon data table for approvals and dimensions. �_ 2 ,/4 ( Ot (57.2 r4 -..— , 10/r6 Du (4tlmm( r �a ,- It 1 /2 - INDUCER - - maw COUNT win non I I Ui �, 1 r r i I L.1 14L, Oa Or ma 1Rr'� iliidni r A co,.. O. } 1 J »n, - Ot (72.24144 - 126,1;010 (,) TOTER TO 1SCV,CTOON TLTA TABLE MR APPROVALS AND m msaa. 2. Model Fl FR Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent . 1 Approval Type: Light Hazard Occupancy Installation Data: Nominal Orifice Thread Size K Factor + US Metric Sprinkler Height Organizations Sprl Number (SIN) lion • 1/2" '/z" NPT (R'/s) 5.6 80 2.2" (56mm) 1, 2, 3, 6, 8 15mm Y2" NPT (R1/2) 5.6 80 (1) R3685 2.2" (56mm) 4 (1) LPC Approval is for Pendent position only. Orientation Deflector to Ceiling ' ., Dimension (Min. - Max.) 1 ' ` .: Upright - 4" - 12" (102mm - 305mm) t q Pendent 6" - 12" (152mm - 305mm) il jtl• ,.- r-.i 4 --; Vertical Sidewall Model Fl FR Quick Response Horizontal Sidewall Sprinkler Deflector: HSW 1 Installation Wrench: Model D Sprinkler Wrench Installation Data: K Factor Approval Sprinkler and TYPe at Organizations Nominal Thread -� Sprinkler A'pro Identification • Orifice Size US Metric Length Light Ordinary Number Hazard Hazard (SIN) - I y" (15mm) y" NPT(R' /z) 5.6 80 I 2.63^ (67mm) 1,2,3,5,8 1,2,5,8 _ R3635 NOTE: UL and ULC Listing permits use with F1 or F2 recessed escutcheon. -• f \ Z Horizontal Sidewall 3. Installation Sprinkler Types Quick response sprinklers are intended for installation Standard Upright as specified in NFPA 13. Quick response sprinklers and Standard Pendent standard response sprinklers should not be intermixed. ' I The Model Fl FR Recessed Quick Response Sprinklers Conventional _ are to be installed as shown. The Model Fl or F2 Escutch- Sidewall (Vertical, Horizontal HSW1) eons illustrated are the only recessed escutcheons to be Recessed Pendent ' used with the Model Fl FR Sprinklers. The use of any other Recessed Horizontal Sidewall HSW1 • recessed escutcheon will void all approvals and negate all warranties. When installing Model Fl FR Sprinklers, use the Model D Sprinkler Wrench. When installing Model F1FR Recessed Finishes ( ' ) (4 Sidewall Sprinklers, use the Model GFR1 Sprinkler Standard Finishes Wrench. Use the Model RC1 Wrench for installing F1FR Sprinlder Escutcheon Recessed Pendent Sprinklers. Any other type of wrench may damage these sprinklers. Bronze Brass Chrome Plated Chrome Plated (3) White Polyester Coated White Painted (3) Temperature Ratings Special Application Finishes Sprinkler Escutcheon Max. Ambient Bulb Sprinlder Escutcheon Temperature Temp Color Bright Brass Bright Brass °C °F Plated Black Plated 57 135 100°F (39°C) Orange Black Paint Black Paint Ordinary 68 155 100°F (38°C) Red 79 175 150°F (66°C) Yellow Off White Off White 93 200 15�F(66°C) Green Satin Chrome Satin Chrome 141 286 225°F (107°C) Blue I (t) Other finishes and colors are available on special order. (1) Not available for recessed sprinklers. Consult the factory for details. ( FM Approvals is limited to bronze and brass, chrome or black Escutcheon Data plated finishes only. ( FP Push- on/Thread -off escutcheon I Esartcheon Model Approvals Musa l Dimension b Ceiling or Wall Dimension F1 1.2,4 X" %" X6"-,(6- Ordering Information (19mm) (19mm) (5mm - 24mm) Specify: F2 1,2,3,4,5,7,8 (13mm) (25mm) (5rmt- 17mrn) 1. Sprinkler Model X6" 2. Sprinkler Type FP 1,2 Full y Recessed (11mm) 3. Orifice Size Push -on/ Thread -oft 1,2 Fully Retracted 'V6" 4. Deflector Type (24mm) 5. Temperature Rating Maintenance 6. Sprinkler Finish ' • The Models F1FR and F1FR Recessed Sprinklers 7. Escutcheon Type • should be inspected quarterly and the sprinkler system 8. Escutcheon Finish (where applicable) maintained in accordance with NFPA 25. Do not clean ' sprinklers with soap and water, ammonia or any other Note: When Model F1FR Recessed sprinklers are cleaning fluids. Remove dust by using a soft brush or gen- ordered, the sprinklers and escutcheons are packaged tie vacuuming. Remove any sprinkler which has been separately. painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to - allow quick replacement of damaged or operated sprin- klers. Prior to installation, sprinklers should be maintained I in the original cartons and packaging until used to mini- mize the potential for damage to sprinklers that would cause improper operation or non - operation. The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputa- ble sprinkler contractors located throughout the United States, Canada and foreign countries Manufactured by The Reliable Automatic Sprinkler Co., Inc. ® Recycled 'a (800)431 -1588 Sales Offices Pa (800)848-6051 Sales Fax (914)668 - 3470 Corporate Offices Revision lines indicate updated or new data www reliablespnnkler.com Internet Address EG Printed in U S A 3iO3 P/N999997( 27