Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Specifications
rWEC2oz� - ��65 /55 75 5�✓ oc / ktay 036 - 21232 - 001 -0801 / 3 0 . R C fiv '` '�' 2 2005 rayoRic BU ILDI NG D� GAR® v►srof� ChampionSeries SINGLE PACKAGE %.,_ e � GAS /ELECTRIC _ � � ` . / � AIR-COOLED �� � j AIR CONDITIONERS � i ii% � / AND D2NA060U 048 \N. % 1 -1/2 THRU 5 NOMINAL TONS \� o 0 oe„, / 10 SEER / 80% AFUE 0 DESCRIPTION These packaged cooling /heating air conditioners are de- Refrigerant charge, and component part numbers are verified signed for outdoor installation. Only utility and duct connec- via computers at installation. Vital run test statistics such as sys- tions are required at the point of installation. tern pressure, motor currents, air velocity and temperature, unit vibration, and gas system safeties are monitored and recorded The gas -fired heaters have aluminized steel tubular heat by the system to insure unit performance. exchangers and hot surface to pilot ignition. They are avail- able in natural gas with field conversion to propane. Equal size, side supply and return duct connections allows easy hook -up of ducts to match low crawl spaces without tran- STANDARD FEATURES and BENEFITS sition pieces. UTILITY CONNECTIONS MADE EASY - Gas and electric OPERATING EFFICIENCY - All units provide high operating utility knockouts are provided through the bottom as well as efficiencies and have a minimum AFUE of 80% and SEER of 10 the side of the unit. Utility connections can be made quickly or above. All efficiencies exceed legislated minimum levels. and with a minimum amount of field labor. Afield supplied and field installed electrical disconnect switch must be installed. ON SITE FLEXIBILITY - All model sizes share a common, compact design cabinet with a single footprint. The installer CONVERTIBLE AIRFLOW DESIGN - The bottom duct open - has the flexibility of setting one curb and placing the proper ings are covered when they leave the factory ready to be used tonnage unit on that curb after the internal load has been de- for a side supply /side return application. If a bottom supply / bot- termined. Field convertible duct connections from side shot to torn return application is desired, you simply remove the two down shot allows the installer to have greater flexibility and panels from the bottom of the unit and place them in the side needs to carry less inventory. supply / side return duct openings. No panel cutting is required and no accessory panel is necessary. Convertible airflow design LOWER INSTALLATION COST - Installation time and costs allows maximum field flexibility and minimum inventory. are reduced by easy power and control wiring connections. The small base dimension means less space is required on CONDENSATE PAN - A non - corrosive, long - lasting, water -tight the ground or roof, plus, the installer can fit this unit between pan is positioned below the evaporator coil to collect and drain all the wheel wells of full size pick -up truck. All models are well condensate. Less collection of stagnate condensate will build - under 500 pounds. up. The condensate pan conforms to ASHRAE 62 -89 standards (Ventilation for Acceptable Indoor Air Quality). All units are completely wired, charged with R -22 and tested prior to shipment. Unique test stations using a new state of the CONDENSATE DRAIN - The heavy duty, 3/4 inch NPTI cop - art computerized process system are used to insure product per connection is more tolerable during installation and is quality. more FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 036 - 21232- 001 -0801 ' DIRECT DRIVE - / T/ _ CONDENSER FAN MOTOR BLOW -THRU DESIGN WITH . , RELIABLE ALUMINIZED STEEL - TUBULAR HEAT EXHANGERS r HIGHLY EFFICIENT ENHANCED COPPER TUBE/ALUMINUM FIN EVAPORATOR COIL / ' _ . _i HIGLY EFFICENT ENHANCED COPPER %.- ' -,�. -" TUBE/ALUMINUM FIN CONDESER COIL C 111.1 LONG LASTING ° � / I I II ll' ; { DECORATIVE IJ1 � PROTECTIVE POWDER PAINT 1 FINISH EARTH •''' "' r COIL GUARD • TONE COLOR - �4. q•r i . l i t I j l i ll 1 4 4. . ' .4 l.I l %.NI REAR AND BOTTOM \` � : �` RETURN AIR AND • ' �- SUPPLY AIR DUCT 0 © t — : HIGH EFFICIENCY OPENING wT 4.,(„). ) �' I; COMPRESSOR 1 `; -/ RIDGIDLY MOUNTED • 'l r ! I . � � HOT SURFACE fr j ` \\ j - -. m � , /`� PILOT ASSEMBLY HEAVY GAUGE � REMOVABLE BASE / - ,':§k, g 4 p / HIGH GRADE ALUMINIZED RAILS j 0 \ IN -SHOT BURNERS • 0 0 " /% 3 -SPEED DIRECT DRIVE , , /. LOW VOLTAGE TERMINAL BLOWER MOTOR WITH B r BLOCK SLIDE -OUT BLOWER ASSEMBLY POWER VENTER SELF- DIAGNOSTIC CONTROLS WITH MOTOR HIGH VOLTAGE "COMFORT-MATCH' SPEED CONTROL TERMINAL BLOCK PHYSICAL DATA MODELS DNA 018 024 l 030 I 036 I 042 I I 048 060 EVAPORATOR I CENTRIFUGAL BLOWER (Dia. x Wd. in.) 10 X 8 10 X 8 I 10 X 8 11 x 10 11 x 10 12 x 11 12 x 11 BLOWER FAN MOTOR HP (Three Speed) Yz Y Y ' Y4 X 1.0 1.0 ROWS DEEP 2 2 2 2 3 _ 3 3 EVAPORATOR FINS PER INCH 14 13 13 15 13 13 13 COIL FACE AREA (Sq. Ft.) 2.25 3.5 3.5 3.5 3.5 4.5 4.5 PROPELLER DIA. (in.) 22 22 22 22 22 22 22 CONDENSER FAN MOTOR HP Y4 Y4 74 Y4 74 Y< Y FAN NOM. CFM TOTAL 1,800 2,200 2,400 2,400 2,400 3,000 3,000 ROWS DEEP 1 1 1 1 1 1 1 CONDENSER FINS PER INCH 13 13 16 20 20 20 20 COIL FACE AREA (Sq. Ft.) 8.3 8.3 11 7 11.7 11.7 14.8 14 8 CHARGE REFRIGERANT 22 (Ibs. /oz.) 3/2 3 / 16 4 /12 4 /3 4 /12 6 /0 5 / 4 FILTER' FACE AREA (Sq. Ft.) / SIZE (NOMINAL) 2.6/20x20 2.6/20x20 2.6/20x20 2.6/20x20 2.6/20x20 3 3/20x12 3.3/20x12 NATURAL GAS BURNER ORIFICE NO. 43 43 43 43 43 40 40 (Drill size) FURNACE PROPANE BURNER ORIFICE NO. SECTION (Drill size) 55 55 55 55 I 55 53 53 GAS CONNECTION SIZE Y NPTI I Y NPTI Yz NPTI I Y NPTI 72 NPTI 72 NPTI y NPTI COMPRESSOR HERMETICALLY SEALED R R R 1 R R S S TYPE (R = RECIPROCATING. S = Scroll) • = Three phase 018 thru 042 size units are supplied with one (1) filter and on three phase 048 and 060 size units two (2) filters are supplied. Single phase units are shipped without fillers See 'FILTER / FRAME KIT on page 3 4 Unitary Products Group 036 - 21232- 001 -0801 RATINGS - Cooling /Gas Heating NET COOLING GAS HEAT CAPACITY 1 SOUND MODEL RATING 2 INPUT OUTPUT AFUE NUMBER TEMP. DNA RISE (dbels) (MBH) (MBH) ( %) OF BURNERS a MBH SEER (F) Range • 018NO3606 17.9 10.0 76 45 36 80.2 2 25 - 55 _ 024NO3606 23 0 10.5 78 45 36 80.2 2 25 - 55 024N05606 23.0 10.5 78 70 56 80.2 3 30 - 60 030NO3606 29 0 10.5 78 45 36 80.2 2 25 - 55 030N05606 29.0 10.5 _ 78 70 _ _ 56 80.2 3 - 30 - 60 036NO3606 34.8 10.0 82 45 36 80.4 2 25 - 55 036NO3625 34.8 10.0 82 45 36 80.4 2 25 - 55 036NO3646 34.8 10.0 82 45 36 80.4 2 25 - 55 036NO3658 34.8 10.0 82 45 36 80.4 2 25 - 55 036N05606 34.8 10.0 82 70 56 80.2 3 25 - 55 036N05625 34.8 10.0 82 70 56 80.2 3 25 - 55 036N05646 34.8 10.0 82 70 56 80.2 3 25 - 55 036N05658 34.8 10.0 82 70 56 80.2 I 3 25 - 55 036N07206 34.8 10.0 82 90 72 80.1 4 30 - 60 036N07225 34.8 10.0 82 90 72 80.1 4 30 - 60 - 036N07246 34.8 10.0 82 90 72 80.1 4 30 - 60 036N07258 34.8 10.0 82 90 72 80 1 4 30 - 60 042NO3606 40.5 10.0 84 45 36 80.4 2 25 - 55 . 042NO3625 40.5 10.0 84 45 36 80.4 2 25 - 55 042NO3646 40.5 10.0 84 45 36 80.4 2 25 - 55 042NO3658 40.5 10.0 84 45 36 80.4 2 25 - 55 042N05606 40.5 10.0 84 70 56 80.2 3 25 - 55 042N05625 40.5 10:0 84 70 56 80.2 3 25 - 55 042N05646 40.5 10.0 84 70 56 80.2 3 25 - 55 042N05658 40.5 _ _ 10.0 84 _ 70 56 80.2 3 25 - 55 042N07206 40.5 10.0 84 90 72 80.1 4 30 - 60 042N07225 40.5 10.0 84 90 72 80.1 4 30 - 60 042N07246 40.5 10.0 84 90 72 80.1 4 30 - 60 042N07258 40.5 10.0 84 90 72 80.1 4 30 -60 048N06506 46.5 10.0 82 80 64 80 3 25 - 55 048N06525 46.5 10.0 82 80 64 80 3 25 - 55 048N06546 46.5 10.0 82 80 64 80 3 25 - 55 048N06556 46.5 10.0 I 82 I 80 I 64 I 80 3 25 - 55 048N09006 46.5 10.0 82 108 86 80 4 30 - 60 048N09025 46.5 10.0 82 108 86 80 4 30 - 60 048N09046 46.5 10.0 82 108 86 80 4 30 - 60 048N09058 46.5 10.0 82 108 86 - 80 4 30 - 60 048N11006 46.5 10.0 82 135 108 80 5 35 - 65 048N11025 46.5 10.0 82 135 108 80 5 35 - 65 048N11046 46.5 10.0 82 135 108 80 5 35 - 65 048N11058 46.5 10.0 82 135 108 - - 80 5 35 -65 _ 060N06506 56.5 10.0 82 80 64 80 3 25 - 55 060N06525 56.5 10.0 82 80 64 80 3 25 - 55 060N06546 56.5 10.0 82 80 64 80 3 25 - 55 060N06558 56.5 10.0 82 80 I 64 80 3 25 - 55 060N09006 56.5 10.0 82 108 86 80 4 30 - 60 060N09025 56.5 10 0 82 108 86 80 4 30 - 60 060N09046 56.5 10.0 82 108 86 80 I 4 30 - 60 060N09058 56.5 10.0 82 108 86 80 I 4 30 - 60 060N11006 56.5 , 10 0 82 135 108 80 5 35 - 65 060N11025 56.5 10 0 82 135 108 I 80 5 35 - 65 060N11046 56 5 10 0 82 135 I 108 80 I 5 35 - 65 060N11058 56 5 10 0 82 135 I 108 I 80 I 5 35 - 65 SEER = Seasonal Energy Efficiency Ratio - the total cooling output in BTU's during a normal annual usage period for cooling divided by the total electric power input in wall -hours dunng the same period. AFUE = Annual Fuel Utilization Efficiency. ' Certified in accordance with the Unitary Small Equipment certification program, which is based on ARI Standard 210/240 a Rated in accordance with ARI Standard 270 Unitary Products Group 5 036 - 21232- 001 -0801 UNIT DIMENSIONS UNIT DIMENSION SIZE "A" "B" VENT AIR OUTLET HOOD 018 THRU 042 33Y 18Y< BLOWER 048 AND 060 41Y 23% SERVICE ACCESS COMPARTMENT PANEL GAS SUPPLY 1) DIA. HOLE CONDENSER COIL (Y" NPTI CONNECTION) UNIT CONDENSATE Z��% ... ,.`..\'`'N CONNECTION %I" NPTI B \`N" . ", lJ q (TRAP RECOMMENDED) I . I j j: 2j (OVERALL) HIGH VOLTAGE CONN. 3% I` �I I � 1%" DIA KNOCKOUT Y REFRIGERANT �� � CONNECTIONS HIGH VOLTAGE CONN. �. �':l ! ` Nopp..00' ` COMBUSTION AIR %" DIA. KNOCKOUT 4 %, i I NLET LOUVERS GAS SUPPLY 1Y<" DIA. KNOCKOUT 1Y Ii " 5; 11 FRONT (Y2" NPTI CONNECTION) 2% I 12% LOW VOLTAGE CONN. 47Y4 3Y 4 1 %" DIA. KNOCKOUT x %" HOLE (O 3X VERALL) (OVERALL) GAS /ELECTRIC CONTROL 19Y, SERVICE ACCESS HIGH VOLTAGE 8% / COMPARTMENT PANEL CONN. 1%2" DIA. FRONT r / KNOCKOUT 11% - -- -- - - - -- ------------------------ �\� GAS SUPPLY 1 %" DIA. KNOCKOUT All dimensions are in inches. They are : (Y" NPTI CONNECTION) subject to change without notice. Certified ♦ �'I(� dimensions will be provided upon request. / �•\ \ : LOW VOLTAGE CONN. '' /e DIA. KNOCKOUT , I ., SIDE SUPPLY AIR OPENING 4� \' 26% 14Y v 6 CONDENSER 28% ./ REAR COIL ��% ,t 14Y \ iii / / 3 Y SIDE RETURN -- %-„<----':----=•- S CONDENSATE BOTTOM SUPPLY " NPTI AIR OPENING ./��i��� �� � AIR OPENING DRAIN Y4" �� iii- -- 13n� 41111100 ./�� 3Y 15 `'14Y � 1 15 15 `I 1 4 28%3 3Y 1% CLEARANCES BOTTOM RETURN (Minim um) AIR OPENING Front 36" ' Units may be installed on combustible floors made from wood or class A. Back 0" B or C roof covering material. Left Side (Filter Access) 24" ' Units must se installed outdoors Overhanging structures or shrubs should not obstruct condenser air discharge outlet Right Side 12" NOTE: Below Unit 0" A 1" clearance must be provided between any combustible material and the supply air ductwork z 36 " (For Condenser Above Unit Air Discharge) The products of combustion must not be allowed to accumulate within a confined space and recirculate Unitary Products Group 17 036 - 21232- 001 -0801 ' TYPICAL APPLICATIONS TYPICAL SLAB ON GROUND INSTALLATION TO POWER SUPPY CONTROL WIRING FIELD SUPPLIED \ TO INDOOR DISCONNECT SWITCH \ THERMOSTAT LOCATED TO REAR OF UNIT.. / �, RETURN AIR k DUCE SUPRY AIR a DDCT TOGAS '� SUPPLY LME 101 r$,. . it /// _ " - �% I t i' SHU F ALV LVE ` - j% 14 TYPICAL ROOF CURB INSTALLATION MANUAL GAS . i SHUT-OFF VALVE -- ^ t`. 44 N 01 I \-' � /, -• 0 DISCONNECT I ' ' •I' ... : � I I %� %%% c ROOF CURB MOUNTED a\ E %� INSTALLATION �m`� ,"""' INSTALLATION , 1 BOTTOM DUCT T TO POWER IIII L ROOF CURB REAR DUCT � II' SUPPLY IHmnn111 ‘ _ ■.. J.. 1.-,_, � �_ I I I I I I I II III II I I I TO GAS / 41 SUPPLY UNE ' " II S� �� CONTROL WIRING / TO INDOOR THERMOS P I n RETURN AIR DUCT V - 4 SUPPLY AIR mm mm MIE= s. ` DUCT SLAB ON GROUND INSTALLATION FRONT CENTER OF GRAVITY OF UNIT OPERAT- OPERATING CORNER „--. UNIT SHIPPING ING WEIGHTS ECONI- ROOF WEIGHT (location, Ibs.) MIZER CURB "C''''> SIZE WEIGHT i'� (Ibs.) (lbs.) W I "B” "C" I ^D^ Os.) (inch /Ibs) c.-_ _- I __ 018 365 360 91 I 88 89 92 ^ / F. 024 365 360 91 88 89 92 49/R ` , 24 030 395 390 98 95 96 99 25 036 400 395 100 96 98 101 40 8 /70 — L 14 "/75 J L 042 415 410 104 100 101 105 048 475 470 119 115 116 120 060 480 475 120 116 117 122 18 . Unitary Products Group 036- 21232- 001 -0801 ROOF CURB DIMENSIONS (8" roof curb also available) • 42% 17% 17% 451/8 40% 437 4 OPENING FOR RETURN AIR DUCT 22 OPENING OR 1 SUPPLY Y AIR DUCT 14 • FRONT , WOOD NAILER INSULATED PANELS RECOMMENDED DUCT SIZE SUPPLY AIR DUCT 1778" x 217" RETURN AIR DUCT 1778" x 16%' ROOF CURB APPLICATION 3:" x 1" WIDE GASKETING FOR CURB FRAME 1" UNIT BASE RAIL AND ALL DUCT SUPPORT SURFACES I / n UNIT BASE por- COUNTERFLASHING WOOD NAILER ' ,/ / CANT STRIP 8" MIN. ABOVE FINISHED ROOF 14" / NSULATION AND ROOFING MATERIAL CURB FRAME EMI I NSULATION ROOF DECK AND ROOFING MATERIAL Unitary Products Group 19