Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
FP5 zO i a - oo - o - oC - , . / 03 stJ 6--_e got sic FNED - Global Project Values: Project Name: IlD EXPERTS AN Standby Hours: 24 WE IN Project ID: 821 7� 0 Tt'Alarm Mins: 5 + 0 Prepared By: ADAM SWEET c ' C ikt,(Derating Factor:1 1.2 Techno logy Group inc Date: 1/22/2010 I bV V oltage Drop Warning Threshold % : 10 Security Automation Fire Alarm -Entertainment Panel ID: [NAC PANEL 5.1 g i Model: Simplex 4009 IDNet Power Extender Max Circuit Current: 2 Amps Location: 5TH FLOOR ELEC ROOM Volts: 24 VDC Max Panel Current: 8 Amps Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop Circuit Name Standby Alarm & Type 1000 Ft. One -Way Ohms EOL �oDrop 1 5.1.1 0.000 0.271 #14 Solid 2.52 120 0.60 20.24 0.80% 2 5.1.2 0.000 0.591 #14 Solid 2.52 185 0.93 19,85 2.70% 3 5.1 3 0.000 0.851 #14 Solid 2.52 200 1.01 19.54 4.20% 4 5.1 4 0.000 0.000 #14 Solid 2.52 0.00 20.40 0.00% Aux 5495(1) Aux Power Out 0.000 0.000 #14 Solid 2.52 0.00 20.40 0.00% 4009 4009 NAC Extender 0.085 0.185 1.713 (Amps) Total Output Power Required Total Standby Current (Amps) 0.085 1.898 Total Alarm Current (Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes / 60 (5 Mins) Total Standby AH Required 2.040 0.158 Total Alarm AH Required Total Combined AH Required 2.20 Wire resistances are based upon an ambient temperature of 72 degrees F. Because of Multiply By The Derating Factor 1.20 the minimal difference between solid and stranded wire no differential was made. Minimum Battery AmpHours Required 2.64 Panel ID: 5495(2) Model: Silent Knight 5495 Power Expander Max Circuit Current: 3 Amps Location: Volts: 24 VDC Max Panel Current: 6 Amps Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop Circuit Name /oDrop Standby Alarm & Type 1000 Ft. One -Way Ohms EOL 1 5495(2) Circuit 1 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% 2 5495(2) Circuit 2 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% 3 5495(2) Circuit 3 0.000 0.000 #14 Solid 1.59 0.00 20.40 0.00% 4 5495(2) Circuit 4 0.000 0.000 #14 Solid 1.59 0.00 20.40 0.00% Aux 5495(2) Aux Power Out 0.000 0.000 #14 Solid 1.59 0.00 20.40 0.00% 5495 5495 Power Expander 0.075 0.205 0.000 (Amps) Total Output Power Required Total Standby Current (Amps) 0.075 0.205 Total Alarm Current (Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes / 60 (5 Mins) Total Standby AH Required 1.800 _ 0.017 Total Alarm AH Required Total Combined AH Required 1.82 Wire resistances are based upon an ambient temperature of 72 degrees F. Because of Multiply By The berating Factor 1.20 the minimal difference between solid and stranded wire no differential was made. Minimum Battery AmpHours Required 2.18 • • Circuit Configuration z Project Information Project Name: ID EXPERTS Project ID: 821 Prepared By: ADAM SWEET Date: 1/22/2010 Ckt. Number: 1 Panel ID: NAC PANEL 5.1 Ckt. Name: 5.1.1 Max Circuit Current: 2 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 2 4906-9104 15cd 0.000 0.050 0.000 0.100 3 4906-9130 15cd 0.000 0.057 0.000 0.171 0 0.000 0.000 0.000 0.000 0 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.271 Ckt. Number: 2 Panel ID: NAC PANEL 5.1 Ckt. Name: 5.1.2 Max Circuit Current: 2 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 4 4906-9104 15cd 0.000 0.050 0.000 0.200 2 4906 -9130 75cd 0.000 0.167 0.000 0.334 1 4906- 913015cd 0.000 0.057 0.000 0.057 0 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.591 Ckt. Number: 3 Panel ID: NAC PANEL 5.1 • Ckt. Name: 5.1.3 Max Circuit Current: 2 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 2 4906 -9130 75cd 0.000 0.167 0.000 0.334 2 4906 -9104 75cd 0.000 0.155 0.000 0.310 3 4906-9104 15cd 0.000 0.050 0.000 0.150 1 4906-9130 15cd 0.000 0.057 0.000 0.057 0.000 0.000 Totals 0.000 0.851 Ckt. Number: 4 Panel ID: NAC PANEL 5.1 Ckt. Name: 5.1.4 Max Circuit Current: 3 Amps Current Draw Each Current Draw Total Qty Device Standby Alarm Standby Alarm Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 _ Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0 000 0 000 F' Ps20 to - -- ov-cz6 6 Simplex LifeAlarm Fire Alarm Controls • UL, ULC, CSFM Listed; FM Approved; 4009 I DNet NAC Extender for Control from 4010 or MEA (NYC) Acceptance* 4100U I DNet Communications; or from Conventional NACs Features Provides additional notification appliance circuit � (NAC) capacity with flexible operation modes and rJ power - limited design Up to 8 NACs Four, Class B (Style Y) NACs are standard: t� • Rated 2 A each for conventional reverse polarity 4009 IDNet 24 VDC notification appliances and providing NAC Extender � multiple operation modes 11111111 11 '�' 4 "� • Can be selected to provide synchronization for Ili Simplex visible notification strobe flashes o Optional IDNet • Capable of controlling TrueAlert non - addressable Channel Repeater notification appliances operating with SmartSyncTM ,___� two -wire control mode ** / ■ `� ∎� i .a'. — Input control options: \ ■ • 2 -Wire IDNet ' x ■ • IDNet addressable communications from a Simplex Communications or '■ % ■ �� model 4010 or 4100U Fire Alarm Control Panel ** t r Fiber Optic IDNet • Or from one or two conventional 24 VDC NACs with I Communications or ', multiple output control options -- - • NAC Control : IDNet communications control benefits: , • Provides status monitoring and individual NAC control ® = IDNet Fiber — using a single address per 4009 IDNet NAC Extender Optic Transmitter • Supports IDNet "Device Level" earth fault location • 4010 (shown) or WALKTEST TM operation is available with either 4100U Fire Alarm input choice Control Panel Internal 8 A power supply /battery charger: Fire Alarm Control Panel with Conventional NACs • Charges internal batteries up to 12.7 Ah or up to 18 Ah batteries in external cabinet • Provides status monitoring of battery, input power, and 4009 IDNet NAC Extender Connection Reference Drawing earth faults Introduction • Rated 8 A for "Special Application" appliances; including Simplex 4901, 4903, 4904, and 4906 Series ADA Compliance. Complying with the notification horns, strobes, horn/strobes, and speaker /strobes requirements of ADA (Americans with Disabilities Act) Rated 6 A for "Regulated 24 DC" appliance power require more notification appliance power than is • available within the fire alarm control panel. When Optional 4009 IDNet NAC Extender modules: additional wer is required, quired, a Simplex 4009 IDNet NAC • IDNet Communications Repeater provides Class B Extender can provide up to 8 A of NAC power with up to (Style 4) or Class A (Style 6) output eight, supervised reverse polarity NACs. • IDNet Communications Fiber Optic Receiver/Repeater, Location Flexibility. The 4009 IDNet NAC Extender available as Class B or Class A can be mounted close to a compatible dedicated host • Four additional Class B NACs, rated 1.5 A for Special panel or can be located remotely for convenient power Application appliances; 1 A for Regulated 24 DC distribution. Multiple operation modes and multiple appliance power connection options further increase location flexibility. • Class A (Style Z), Two Circuit Adapter Module Additional Information. For additional operation detail UL Listed to Standard 864 and application information, refer to Installation Instructions 574 -181 and field wiring diagram 842 -068. External Accessories • ULC listed model is 4009- 9202CA. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. IDNet communication fiber optic transmitters. See CSFM Listing 7300- 0026: 214foallowablevaluesand /orcondtionsconcerning • For applications requiring the data integrity available material presented in this document. II is subject to re- examination, revision, and possible With fiber optic communications cancellation. Accepted fa use – City of New York Department of Buidngs – MEA35 -93E. P Addtional listings may be applicable; contact your local Simplex product supplier for the • Available as Class B (Style 4) or Class A (Style 7) latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. • Mounts in standard six-gang electrical box " SmartSync tom/strobe operation is protected under U.S. Patent No. 6,281,789. IDNet External battery cabinet for 18 Ah batteries addressabl e communications are protected under U.S. Patent Nos. 4,796,025; 5,966,002; and 6,034,601. 4100U requires revision 11 software or higher for t Simplex WALKTEST service testing is protected under U.S. Patent No. 4,725,818. compatiWity. 4010 requires revision 2 software a higher for compatibility. S4009 -0002 -5 3/2009 Application and Operation Information Hardwire Control Applications. For applications where an existing (or new) conventional NAC needs IDNet Addressable Communications Compatible. additional power, the 4009 IDNet NAC Extender can be Up to five, 4009 IDNet NAC Extenders can be controlled controlled directly from the NAC. Either one or two on a single IDNet communications channel. Each output NACs, from either the same, or from different host fire NAC can be individually controlled for general alarm or alarm control panels, can be connected to control the 4009 selective area notification requiring only one point IDNet NAC Extender output NACs. Multiple control address per Extender. Individual Extender NACs can also selections provide flexible operation. (Refer to page 4 for be manually controlled from the host panel. IDNet more detail.) Alarms from the host panel will activate the controlled extenders will inform the host panel of troubles four, 4009 IDNet NAC Extender NACs (or optionally, via IDNet communications. 4100U control panels control eight NACs) to extend the alarm. using multi -point rules, refer to data sheet S4090 -0011 for details. The 4009 IDNet Extender monitors itself and each of its output NACs for trouble conditions, including earth Optional IDNet Repeaters. IDNet communications faults. Extenders wired to conventional NACs will can be repeated with the optional IDNet Repeater Module indicate a trouble by opening the path to the NAC's or with the optional Fiber Optic Receiver Module. Up to end -of -line resistor, but retaining the ability to respond to 100 of the IDNet channel points can be repeated once alarms. Individual troubles are also annunciated by LEDs (refer to pages 3 and 5 for details). Repeated IDNet located on the 4009 IDNet NAC Extender main circuit communications also support the "device level" earth board. (Refer to page 7 for more diagnostic information.) fault location utility of the host panel. Product Selection Standard Models Model Description 4009 120 VAC input 4009- 9202CA* 4009 IDNet NAC Extender with 4, Class B (Style Y) NACs and 8 A power supply 4009 -9301 240 VAC input * ULC listed model Optional Modules (for on -site installation) Model Description Comments Additional four point NAC module, rated 1.5 A Special 4009 -9807 Application appliances; 1 A for Regulated 24 DC appliance One maximum power, Class B (Style Y), 4009 -9808 Dual Class A (Style Z) adapter (for two NAC outputs) Select as required (4 maximum) 4009 -9809 IDNet Repeater, output is Class A (Style 6) or Class B (Style 4) Select either an IDNet Repeater or a 4009 -9810 Fiber Optic Receiver Class B (Style 4) Fiber Optic Receiver as required 4009 -9811 Class A (Style 7 fiber, Style 6 IDNet) 4009 -9805 Red Applique for door Select if required 2975 -9801 Semi -Flush Trim Kit Beige trim 1- 7/16" wide (78 mm), use if required for 2975 -9802 Red trim semi -flush installations Battery Selection (select battery size per system requirements) Model Description Comments 2081 -9272 6.2 Ah Battery, 12 VDC 2081 9274 10 Ah Battery, 12 VDC Two batteries are required, 24 VDC 2081 -9288 12.7 Ah Battery, 12 VDC operation 2081-9275 18 Ah Battery, 12 VDC Requires external battery cabinet, two batteries are required, 24 VDC operation External Accessories (select per system requirements) Model Description Comments 4090 -9105 IDNet Fiber Optic Class B (Style 4) operation Mounts in six -gang electrical box, refer to 4090 -9107 Transmitter Class A (Style 7) operation page 4 for mounting details 4009 -9801 External battery cabinet for up to 18 Ah batteries, beige 16-1/4" Wx 13-1/2" H x 5-3/4" D (413 mm x 343 mm x 146 mm) 4081 Series End -of -Line Resistor Harnesses; see data sheet S4081 -0003 for details 2 S4009- 0002 -5 3/2009 Typical IDNet Connection Example i Typical IDNet compatible devices (Refer to individual devices for actual wiring requirements, some wiring is not shown.) * =wore' rt IDNet addressable communications channel, r �shown Class B (Style 4) Output NACs, four standard, Conventional NAC operation (horns) eight with expansion option ilk F ' - Select conventional Lt , ; •, t.: ,,_ .....„ - -; t or Smart Sync NI 4100U (shown) or 4010 Fire mG r. �operation per NAC Alarm Control Panel '6 01710 C7) 4 11k Smart Sync operation (horns and strobes) __ =---'''' �� 4009 IDNet NAC Extender with _ optional internal IDNet Repeater II C �-- operation Conventional (strobes ) I • Repeated IDNet Channel: ®Hpw® up to 100 devices maximum on repeater output, 250 devices total on IDNet Channel r' IDNet devices and additional 4009 IDNet NAC Extender(s) NOTE: Up to five (5) 4009 IDNet NAC Extenders may be connected to one IDNet channel. IDNet communications can be repeated only once (can pass through only one series connected repeater or one fiber optic receiver). Typical Fiber Optic System Connections Two fiber cables, 3000 ft Output NACs 4090 -9105, Class B (914 m) maximum distance _ __ (Style 4) Output Fiber i di N1 Illllllllllllllllllllllllllllllllllllllllllllllllllllllllllll Optic Transmitter +„ IDNet addressable communications channel Class B (Style 4) or Class A (Style 6), Class B shown Repeated IDNet Channel: up to 100 devices maximum 111111111111111111111111111111111111111111111111111111E1 Four repeater output, 250 devices total on IDNet Channel Four fiber cables, 3000 ft 4010 or 4100U Fire (914 m) maximum distance Alarm Control Panel 24 VDC power for l A i is i0 i 14+jr fiber optic transmitters _■ 1 4090 -9107, Class A (Style 7) V o '' R Output Fiber Optic Transmitter IIIM 1_ /111111li•li 4009 IDNet NAC Extenders with optional Output NACs internal IDNet Fiber Receivers NOTE: Up to five (5) 4009 IDNet NAC Extenders may be connected to one IDNet channel. IDNet communications can be repeated only once (can pass through only one series connected repeater or one fiber optic receiver). Fiber optic transmitters connect to only one 4009 IDNet NAC Extender. 3 S4009- 0002 -5 3/2009 Hardwire Control Connection Information Smart Sync Notification Appliance Control NAC Input Selections. The 4009 IDNet NAC The TrueAlert Notification Appliance product line Extender can be selected to: includes addressable and non - addressable operation. • Track input NAC operation or to provide a locally Non - addressable models are available with 2 -wire generated code, selectable per NAC input Smart Sync operation or conventional 4 -wire operation. If selected for local coding, NAC outputs can be either The following details apply to use with the 4009 IDNet • Temporal Coded or 60 Beats /min March Time Coded, NAC Extender: one code selection per extender (input NACs must be on • TrueAlert non - addressable models with SmartSync continuous with Alarm) operation allow audible notification to be separately controlled over the same wire pair that controls • Additionally, NAC outputs can be selected to provide visible notification (protected under U.S. Patent No. the Simplex strobe synchronization signal. This signal 6,281,789) will synchronize the flashes of synchronized strobes but • 4009 IDNet NAC Extenders can be selected to provide will be ignored by free -run strobes and audible devices. Smart Sync operation whether controlled by IDNet (Strobes are for operation by noncoded NACs.) communications or conventional NACs NAC input to NAC output control can be selected for • IDNet control allows output NACs to be individually standard and optional NACs per the following table: selected for conventional or Smart Sync operation Conventional NAC Output Operation Options • With NAC input control, all output NACs are selected for either conventional or Smart Sync operation Input A B C • Class A (Style Z) Smart Sync operation requires NAC 1 NACs 1 & 2, 5 & 6 NACs 1 -4 NACs 1 -8 SmartSync Control Module (SCM) 4905 -9938 (refer to NAC 2 NACs 3 & 4, 7 & 8 NACs 5 None data sheet S4905 -0003 for details) SmartSync NAC Output Operation • Refer to data sheet S4009 -0003 for TrueAlert Input NAC Control Function addressable operation details, contact your local Simplex NAC 1 Strobe Control _All NAC outputs (1 -8) product supplier for further information on specific NAC 2 Horn Control TrueAlert notification appliances Hardwire Control NAC Connection One -Line Reference Diagram Up to eight (8) output NACs total; hardwire control can be selected to map NAC inputs to different combinations of NAC outputs depending on system requirements NAC 1 input 0 0 (see Note 1) i \ _ l IIIIIIIIIII Conventional NACs I. ► With hardwioutputre control, NAC s are all ,, Output conventional or all " - - -- - -- �____ t- NACs SmartSync operation - Illlllli SCM 4009 IDNet NAC Extender C C 7 • ,) Fire Alarm Control Panel with Conventional NACs SmartSync operation \ 4905 -9938 SmartSync Control Module is required NAC 2 input for Class A output wiring of SmartSync NACs (optional, see Note 1) To additional 4009 IDNet NAC Extenders (up to four (4), 4009 IDNet NAC Extenders per NAC); see Note 2 Notes: 1. For separate audible and visible output NAC control, or SmartSync NAC output operation, two (2) input NACs are required. NAC 1 is "on- until -reset" and NAC 2 is "on-until-silenced." 2. To synchronize strobe flash outputs for up to four (4) 4009 IDNet NAC Extenders, use the synchronized strobe output from a Synchronized Flash Module (4905 -9914 for Class B operation, 4905 -9922 for Class A operation) or, if available, from a NAC selected to provide synchronized strobe flash output. NOTE: DO NOT USE a NAC selected for SmartSync operation for this function. Refer to Installation Instructions 574 - 161 for additional Information and application guidance 1 4 S4009- 0002 -5 3/2009 4009 IDNet NAC Extender S •ecifications 120 VAC Input (4009 -9201) 3A @ 102 -132 VAC, 60 Hz Input 240 VAC Input (4009 -9301) 1.5A @ 204 -264 VAC, 50/60 Hz Ratings Hardwire Control from External Conventional reverse polarity operation NACs, Input Requirements 5 mA maximum; 16 to 33 VDC Total Rating 8 A, Special Application appliances 6 A, Regulated 24 DC appliance power Standard NACs 2 A each, Special Application or Regulated 24 DC appliance power Optional NACs 1.5 A each, Special Application appliances (requires 4009 -9807) 1 A each, Regulated 24 DC appliance power Special Application Simplex 4901, 4903, 4904, and 4906 Series non - addressable horns, strobes, Output Ratings Appliances and combination horn/strobes and speaker /strobes (contact your Simplex product representative for compatible appliances) Regulated 24 DC Power for other UL listed appliances; use associated external synchronization Appliances modules where required Strobe Operation Up to 33 strobes per NAC can be synchronized; output NACs configured for Simplex synchronized strobe operation are synchronized to each other Auxiliary Output 500 mA @ 24 VDC nominal Optional Modules Ratings Input Power 70 mA @ 24 VDC, system supplied IDNet Input, One Address Maximum distance from IDNet source is 2500 ft (762 m) IDNet Repeater Repeated IDNet output for up to 100 devices (total IDNet devices not to exceed Module 250 per channel) (4009 -9809) IDNet Output Specifications Maximum distance to farthest device is 2500 ft (762 m) Total distance including "T- taps" is 10,000 ft (3048 m) Class A (Style 6) loop maximum distance is 2500 ft (762 m), no "T" taps Fiber Optic Receiver Modules 4009 -9810, Class B (Style 4), 65 mA @ 24 VDC, system supplied Input Current 4009 -9811, Class A (Style 7), 80 mA @ 24 VDC, system supplied IDNet Output Specifications Same as those for Repeater Module (see above) Fiber Optic Transmission Distance 3000 ft (914 m) maximum General (LED status indicators are listed on page 7, dimensions and mounting details are on page 6) Operating Temperature 32° to 120° F (0° to 49° C) Operating Humidity Range 10% to 90% RH from 32° F to 104° F (0° C to 40° C) Wring Connections' Terminal blocks for 18 AWG (stranded) to 12 AWG (solid) Fiber Optic Transmitter Specifications Input Voltage 18.9 -32 VDC from compatible listed fire alarm supply 4090 -9105, Class B (Style 4), 30 mA @ 24 VDC Input Current 4090 -9107, Class A (Style 7), 35 mA @ 24 VDC Multimode, graded index, 50/125pm, 62.5/125 pm, 100/40 pm, or 200 pm Fiber Optic Connections and cable Type ST connectors requirements 4090 -9105, Class B (Style 4) operation, two fiber cables required 4090 -9107, Class A (Style 6) operation, four fiber cables required Module Size (with mounting bracket) 6- 13/16" W x 3 -3/4" H x 1 -1/8" D (173 mm x 95 mm x 29 mm) Green LED flashing = transmit On -board Status Indicators Red LED flashing = receive Separate red LED on 4090 -9107 = Class A (Style 7) receive Communications Simplex IDNet Fiber Optic Transmission Distance 3000 ft (914 m) maximum Wiring Connections' Terminal blocks for 18 AWG (stranded) to 12 AWG (solid) Operating Humidity 10% to 90% RH from 32° to 104° F (0° to 40° C) Operating Temperature 32° F to 120° F (0° to 49° C) Metric wire equivalents: 18 AWG = 0.82 mm 12 AWG = 3.31 mm 5 94009- 0002 -5 3/2009 4009 IDNet NAC Extender Mounting and Module Placement Information 1 4 16 -114" (413 mm) id F Cabinet depth 4 -1/4" (108 mm) � . I (277 mm) I Door, 518" —. 6 www (16 mm) thick — O O o o — �► [ 0 ®I 1 � 11' 1___ I ni M I I o l"i__1 :i 1_T - - 1 o ® o p _ iTirlit7.7i 117C MI Optional Class A 4009 -9807 Additional Four 13 -1/2" adapter modules point module (shown with ^' (343 mm) o ` Class A adapters) L ® Exposed cabinet I I dimension for ---►' f— I d System Module • o semi -flush mount 1 1 ` -. 0 1" (25.4 mm), Knockouts for screw IDNet repeater or 1 -3/8" (35 mm) with or nail mounting holes fiber optic receiver semi -flush trim 9 o oJW —O e 0 0 [ 1 I co I � I 4 12" (305 mm) .4 I I � I 0 I 1 Battery location, no conduit entry or wiring in I I this area (12.7 Ah battery outline shown) I CD I I O 0i } I / j--' Semi -flush trim option Non -power limited wiring area (AC input) 1- 3/16" wide (30 mm), --" 3/8" (9.5 mm) thick — Wall surface reference for semi -flush mount NOTE: Recommended conduit entrance varies with module selection. Refer to general installation instructions 574 -181, specific module installation instructions, and to field wiring diagrams 842 -068 before locating conduit entrance. 4009 IDNet NAC Extender Cabinet with Door Detail a Optional red applique (4009 -9805 ) 4009 IDNet' NAC EXTENDER sSimplex 6 84009- 0002 -5 3/2009 4090 - 9105/9107 IDNet Fiber Optic Transmitter Mounting Information Surface mount box: Simplex model 2975 -9217 (ordered separately) • • • • • a Flush mount masonry box: I use 6 -gang box, RACO # 960, 2 -1/2" deep o 0 0 0 o o (64 mm), or RACO # 965, 3-1/2" (89 mm) • • • • • • I I deep, or equal (supplied by others) <d'1 0 1p= t O Flush mount ganged boxes: use 6 -gang box, 1 -1/2" (38 mm) �` ' I■ I I I a � minimum depth; six, RACO # 400 ' r • I • • _ . �= or equal, (supplied by others) ION • I - , li r O O 0 0 0 0 0 0 ' IDNet fiber optic transmitter: 4090 -9107, Shown, Class A (Style 7) output 4090 -9105, Not shown, Class B (Style 4) output INSTALLATION NOTE: Fiber optic cable bend radius should be 2" (51 mm) minimum, or per Manufacturer's specification. 0 0 0 0 0 O qr-" N Six -gang blank cover plate Mulberry Metal Products 97156 or equal (by others) Service Diagnostic Features Power -up Self- Diagnostics. Upon power -up, the LED Status Indicators are provided for the following: 4009 IDNet NAC Extender tests each module and • Each NAC (standard and optional) has a dedicated performs earth fault diagnostics. Trouble conditions are yellow LED that: communicated to the host control panel and are also — During supervision provides a slow flash to indicate displayed on diagnostic status LEDs in the 4009 IDNet a short circuit condition and a fast flash to indicate NAC Extender. When connected via IDNet communications, detailed status information is available an open circuit at the host. When controlled with conventional NAC — During an alarm, the LED follows the NAC output inputs, common troubles are signaled by providing a (on steady or flashing with coded output) polarized open circuit that disconnects the NAC wiring • Four, general status yellow LEDs provide nine from its end -of -line resistor but still allows a reversed separate indications listed in priority of urgency. As a polarity alarm to be received. trouble is eliminated, any remaining trouble(s) will Door Mounted Reference Label. The 4009 IDNet then be indicated until the 4009 IDNet NAC Extender NAC Extender has a detailed programming and is returned to normal operation. diagnostic label inside the front door that provides a quick • AC power status is indicated by a green LED that is reference for both installation and checkout. on when AC is normal. During low AC (brownout) conditions or with no AC, the LED is off. Additional power and battery status is indicated by the general status LEDs. 7 S4009- 0002 -5 3/2009 4009 IDNet NAC Extender Current Chart Panel Module Selection (shaded model numbers are optional modules) Model Description Supervisory Actual Alarm Current Actual Alarm Current Supervisory 4009 -9201 120 VAC input Basic Panel 85 mA 85 mA 185 mA 185 mA 4009 -9301 240 VAC input 4009 -9807 Additional Four Point NAC 40 mA + + NAC loads + NAC loads (add below) (add below) 4009 - 9808 Dual Class A Ada (current — included in basic panel value) 4009 -9809* IDNet Repeater 70 mA 70 mA 4009 - 9810 * Fiber Optic Receiver, Class B 65 mA + 65 mA + 4009 - 9811 * Fiber Optic Receiver, Class A 80 mA 80 mA IDNet Devices, 0.7 mA each, maximum of 100 Total devices + Total devices (A1) + (see note 5) x 0.7 mA each x 0.7 mA each Auxiliary Power Output, calculate per total 500 mA + 500 mA (A2) + device requirements (see note 5) maximum maximum Total Supervisory Current = (A) + Total 4009 IDNet NAC Extender Panel Alarm Current = (B * Only one of these three modules can be chosen for a single 4009 IDNet NAC Extender. t NOTE: IDNet Fiber Optic Transmitter current is supplied from the host fire alarm control panel. NAC Loads NAC Type NAC Circuit # NAC Alarm Current Circuit 1 + Circuit 2 + Standard Panel NACS, 2 A maximum per NAC (see note 5) Circuit 3 + Circuit 4 + Circuit 5 + Optional Four Point NAC Module, 1.5 A maximum per NAC (see note 5) Circuit 6 + Circuit 7 + Circuit 8 + Total NAC Loads Alarm Current = (C) Total 4009 IDNet NAC Extender Panel Alarm Current (enter B1 from above) = (B2) + Procedure: Total Alarm Current = (0) 1. Calculate total panel supervisory current (A). 2. Calculate total panel alarm current (B1) [convert mA to A, example: 350 mA = 0.35 A]. Copy (B1) into block (B2). 3. Calculate total NAC loads alarm current from notification appliance ratings (C). 4. Add (C) + (B2) to determine total alarm current (D). 5. Total of IDNet Device Current (Al) + Auxiliary Power Output Current (A2) + NAC Loads Alarm Current (C) is 8 A maximum. 6. Refer to Simplex battery selection document 900 -012 for recommended battery size for specific standby requirements (i.e. 24 hours supervisory, 5 minutes of alarm). Internal cabinet space is provided for batteries up to 12.7 Ah. Tyco is a registered trademark of Tyco International Services GmbH and is used under license. Simplex, the Simplex logo, LifeAlarm, IDNet, WALKTEST, SmartSync, and TrueAtert are trademarks of Tyco International Ltd and its affiliates and are used under license. 13 Simplex Tyco Safety Products Westminster • Westminster, MA • 01441 -0001 • USA 54009-0002 -5 3/2009 o www.tycosafetyproducts -usa wm.com © 2009 Tyco Safety Products Westminster. All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice. 6Simplex TrueA /erf Multi - Candela Notification Appliances UL, ULC, CSFM Listed; FM Approved; SmartSyncTM Operation AudibleNisible Notification MEA (NYC) Acceptance* with Horn and Synchronized Flash, Non - Addressable • Features = — Audible /visible (AN) notification appliances with efficient electronic horn and high output xenon strobe, available for wall or ceiling mount • Operation is compatible with ADA requirements (refer _ — ■�■ to important installation information on page 3) • Rugged, high impact, flame retardant thermoplastic (..... ' housings are available in red or white with clear lens F I R I R E Operates over a two -wire SmartSync circuit to provide: • Horns that are controlled separately from strobes on the F , I R E same two -wire circuit • "On- until - silenced" and "on -until- reset" operation on the same two-wire pair _ 'J t, l L,f • SmartSync horn activation of Temporal pattern, March 1 FIR t� �i Time pattern (at 60 BPM), or on continuously I E � � • Strobe appliances on the same circuit operating at a , 11 „ synchronized 1 Hz flash rate 1, • Class B (Style Y) operation requires connection to a r compatible SmartSync NAC or to SmartSync Control Module (SCM) 4905 - 9938 Wall and Ceiling Mount A /Vs • Class A (Style Z) operation when connected to the Descri • tion 4905 -9938 SCM or with 4100U series fire alarm control - panel NACs Multi - Candela TrueAlert ANs with horn and synchronized strobe provide convenient installation Wall mount ANs features: to standard electrical boxes. The enclosure designs are • Wiring terminals are accessible from the front of the both impact and vandal resistant and providing easy access for installation, p provide a convenient housing Pr g Y strobe intensity selection. Since each model can be inspection, and testing selected for strobe intensity output, on -site model • Covers are available separately to convert housing color inventory is minimized and changes encountered during • Available UL listed sound damper for locations construction can be easily accommodated. requiring attenuation of 5 to 6 dBA (stairwells, small Wall mount A/V housings are a one -piece assembly rooms, highly reverberant areas, etc.) (including lens) that mounts to a single or double gang, or Optional adapters and wire guards: 4" square standard electrical box. The cover can be • Wall mount A/V adapters are available to cover surface quickly removed (a tool is required) and covers are mounted electrical boxes and to adapt to Simplex available separately for color conversion. 2975 -9145 boxes Ceiling mount ANs install using standard 4" electrical • UL listed red wire guards are available for wall or boxes. Color choice is determined by model number. ceiling mount ANs Visible notification appliance (strobe): Strobe Intensity Selection • 24 VDC xenon strobe; intensity is selectable as 15, 30, During installation, a selection plug at the back of the 75, or 110 candela with visible selection jumper secured housing determines the desired strobe intensity. An behind strobe housing attached flag with black letters on a highly visible yellow • UL listed to Standard 1971 background allows the selected intensity to be seen at the • Regulated circuit design ensures consistent flash output side of the strobe lens. and provides controlled inrush current • This product has been approved by the California State Fire Marsha (CSFM) pursuant to Section 13144.1 of the California Health and Safely Code. See CSFM Using Audible notification appliance (horn): 71254026:317 for allowable values andor conditions concerning materid presented inthis • document It is subject to re- examination, revision, and possible cancellation. Accepted for • Low current, 24 VDC electronic horn with harmonically use —City of New York Department of Buidn p gs — MEP,35 -93E. Refer to page 2 for listing rich sound output suitable for either steady or coded status of wire guards. Addhonal listings may be applicable; contact your local Simplex operation (Temporal or 60 BPM March Time pattern) product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. • UL listed to Standard 464 ** Simplex multi- candela SmartSync two-Wre horn/strobe app liance operation is protected under one or more of the blowing U.S. Patent Numbers: 5,559,492; 5,622,427; 5,865,527; 5,886,620; 6281,789; 6954,137, 7,005,971; and 7,006,003. S4906- 0002 -4 12/2007 Strobe Application Selection Smart Sync Two -Wire Control Proper selection of visible notification is dependent on Smart Sync operation mode allows a two -wire circuit to occupancy, location, local codes, and proper applications provide the ability to activate both the horn and strobe on of: the National Fire Alarm Code (NFPA 72), ANSI the same NAC and then allow the horn to be silenced A117.1; the appropriate model building code: BOCA, while the strobe remains flashing. The horn operates as ICBO, or SBCCI; and the application guidelines of the "on- until- silenced" while the strobe operation is Americans with Disabilities Act (ADA). "on- until- reset." Synchronized Strobes SmartSync Control Sources Multiple Strobes. When multiple strobes and their • 4006, 4008, 4100U, and 4010 Fire Alarm Control reflections can be seen from one location, synchronized Panels (refer to individual product data sheets for more flashes reduce the probability of photo- sensitive reactions information) as well as the annoyance and possible distraction of • 4009 IDNet NAC Extender (refer to data sheet random flashing. The multi - candela strobes of these A/Vs S4009-0002) are synchronized by the controlling SmartSync operation • Smart Sync Control Module (SCM) 4905 -9938 (refer to NAC. data sheet S4905 -0003) Additional Smart Sync compatible notification appliances include separate horns and combination Product Selection horn/strobe notification appliances. Multi - Candela ANs Model Mounting Housing Color "FIRE" Lettering Description 4906 -9127 Wall Red White 4906 -9129 White Red Horn with Multi- Candela Strobe; strobe intensity selectable as: 15, 30, 75, or 110 candela; operates with Smart Sync two -wire 4906 -9128 Ceiling Red White control 4906 -9130 White Red Wall Mount A/V Accessories Model Description Dimensions • 4905 -9937 Red Surface Mount Adapter Skirt; use to cover 1 -1/2" (38 mm) deep 5 -3/8" H x 5 -1/4" W x 1 -5/8" D 4905 -9940 White surface mounted boxes (136 mm x 133 mm x 41 mm) depth with strobe = 4 -3/8" (111 mm) 4905 -9931 Red Adapter Plate for mounting to Simplex 2975 -9145 box (typically for 8 -5/16" x 5-3/4" x 0.060" Thick retrofit, may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975 -9145 Red Mounting Box, requires Adapter Plate 4905 -9931 7 -718" x 5-1/8" x 2 -3/4" D (200 mm x 130 mm x 70 mm) Optional Sound Damper; package of 20; field installed adhesive backed 4905-9838 horn output attenuator; reduces output 5 to 6 dBA 1 -3/4" Diameter (44.5 mm) NOTE: After Sound Damper installation, measure sound level to ensure with 0.31" (8 mm) sound opening compliance with applicable code requirements SmartSync Control Module Model Description Dimensions 4905 -9938 SmartSync Control Module with Class B or Class A output; mounts in 4" 4" x 4 -1/8" x 1 -1/4" D (102 mm) square box; refer to data sheet S4905 -0003 for details (102 mm x 105 mm x 32 mm) Replacement Covers for Wall Mount ANs Model Description Dimensions 4905 -9994 Red cover with white "FIRE" lettering 5 -1/8" H x 5" W x 1 -1/2" D 4905 -9995 White cover with red "FIRE" lettering (130 mm x 127 mm x 38 mm) Wire Guards and Ceiling Mount AN Adapter Model Description Dimensions 4905 9961' Wall mount red wire guard with mounting plate, compatible with semi -flush 6- 1/16" H x 6- 1/16" W x 3-1/8" D or surface mounted boxes (154 mm x 154 mm x 79 mm) 4905 -9927' Red Wire Guard for mounting to flush mounted electrical box 8 -1/2" x 6-1/8" x 3" (216 mm x 156 mm x 76 mm) 4905 -9928• Ceiling Red Adapter Plate, required to mount guard to surface 9" x 7" Mount mounted electrical box (229 mm x 178 mm) 4905 -9915 White Surface Mount Adapter Box Extension, use to cover 4 -3/4" x 6 -7/8" x 1 -1/2" deep, 4905 -9916 Red 1 -1/2" deep surface mounted boxes (121 mm x 175 mm x 38 mm) * UL listed by Space Age Electronics Inc. 2 S4906- 0002 -4 12/2007 AN S s ecifications Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range UL Listed Rating Regulated 24 DC; see Note 1 below ULC Listed Rating 20 VDC to 30 VDC per ULC S526-M878 Flash Rate and Synchronized NAC Loading 1 Hz; with up to 35 synchronized strobes maximum per NAC • Environmental; Temperature and Humidity 32° to 122° F (0° to 50° C); 10% to 93 %, non -condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm to 3.31 mm ; two wires per terminal for in /out wiring Horn Output Characteristics 2400 to 3700 Hz sweep, modulated at 120 Hz rate Horn Output Voltage 16 VDC 24 VDC 33 VDC Ratings Sound Type (see Note 2) Steady Coded Steady Coded Steady Coded @ 10 ft (3 m) UL 464 Reverberant Chamber 86 dBA 82 dBA 88 dBA 84 dBA 90 dBA 86 dBA (see Note 2) Anechoic Chamber 92 dBA 91 dBA 94 dBA 95 dBA 96 dBA 96 dBA Housing Dimensions (with lens) 5 -1/8" H x 5" W x 2 -3/4" D (130 mm x 127 mm x 70 mm) Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Wall Strobe Setting (see Note 3 below) 75 mA 116 mA 221 mA 285 mA Mount Reference RMS Currents 18 VDC 67 mA 103 mA 196 mA 253 mA at other voltages 24 VDC 50 mA 77 mA 147 mA 190 mA Housing Dimensions (with lens) 4 -3/4 L" x 6-7/8" W x 2 -5/8" D (121 mm x 175 mm x 67 mm) Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Ceiling Strobe Setting (see Note 3 below) 86 mA 132 mA 250 mA 320 mA Mount Reference RMS Currents 18 VDC 76 mA 117 mA 222 mA 284 mA at other voltages 24 VDC 57 mA 88 mA 167 mA 213 mA NOTES: 1. "Regulated 24 DC" refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired, changes effective May 1, 2004. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the appliance. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. 2. Coded values are typical of the output measured with a Temporal coded or a March Time coded pulse and with a sound level meter reading on a "fast" setting. Under the same test conditions, coded horn output "peak" sound level readings are typically 4 dBA higher. Anechoic horn output ratings are typically more representative of actual installed sound output. 3. Currents are with horn on steady. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) Installation Reference, Surface or Semi -Flush Mounting O Mounting is compatible with single gang, double gang, and / 4" (102 mm) square boxes, a I ° ( 1 I IMPORTANT! WALL MOUNT 1-1/2" (38 mm) deep, by others INSTALLATION HEIGHT REFERENCE Optional 4905 -9838 — MY `— Sound Damper, field attached I I I Bottom of lens to attenuate sound 5 to 6 dBA — is either even _ I wit or slightly Electrical dro ^ I ' ab ove bottom box outline Wring access hole �241F-4! % I o f compatible ���I - 1 boxes II Wring terminals for ,I p _ II is i ll � 1 SmartSync operation - II Mountin Holes: i NFPA 72 requires 80" (2.03 m) 4" square (4) � "`0s'° ® I Single gang (2) that the entire lens minimum � - 111 1, be not less than �,, 'r � Double gang (3) 80" and not greater N� than 96" above the Transparent housing finished floor and len assembly Intensity selection plug, accessible only from rear of housing, irl, 11 n E factory setting is 15 cd Removable cover Strobe intensity (tool required) viewing slot 3 S4906 -0002 -4 12/2007 Ceiling Mount AN and Guard Installation Reference Ceiling reference, 4" (102 mm) square box, Optional 4905-9928 Adapter Plate, surface mounted box 1 -1/2" (38 mm) minimum depth required for surface mounted electrical box Four mounting clamps included, two each side ■ lirrimilmill9lir 1II I eilin , i L� flush m ounted referencebox ' I� I I Optional 4905 -9915/ -9916 Adapter, recommended for surface mounted box -- - Wiring terminals are Optional 4905 -9927 11111111114 Red Wire Guard located behind the housing 0—...... F - ' E End View _..- 0 , iiii 4 IJ Strobe intensity viewing slot -- r" – Intensit selection plug, ---1 accessible only from rear of lens housing; factory setting is 15 cd Wall Mount Installation Reference; Adapter Plate, Guard, and Adapter Skirt Surface Mounting Reference 2975 - 9145 Box with Optional Adapter Skirt and Optional Wire Guard 11 7 Surface mount conduit and — — - O box shown for reference 4" (102 mm) square P /711 I M.I I�I1l1 r '�"^ . • box profile, 1 -1/2" 1111 II�'I1II I�I�II I II (38 mm) deep _ l� ll� Mil P l��i����- ���l�l, l Q O Optional Wire Guard UI I ' I 4905-9961 � I 'I P V I i , Wi ° i i � I � _ 4905 -9931 Adapter Plate Optional Surface Mount Adapter Skirt, . 1 O 4905 -9961 Optional Wire Guard 1 -1/2" deep: 4905 -9937, Red; (shown here for reference only, 4905 -9940, White (conduit knockouts 4905 -9931 Adapter Plate can be used on other mounting options) are provided on all four sides) Tyco is a registered trademark of Tyco International Services GMBH and is used under license. Simplex the Simplex logo, IDNet TrueAlert, and SmartSync are trademarks of Tyco International Ltd and its affiliates and are used under license. NPPA 7 2 and ,National Fire Alarm Code are trademarks of the National Fire Protection Association (NFP.4). 13 Tyco Safety Products Westminster• Westminster. MA • 01441 -0001 • USA S4906 -0002 a 12/2007 www. tycosafetyproducts- usa -wm. corn 02007 Tyco Safety Products Westminster. All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice. El Simplex TrueAlert Multi - Candela Notification Appliances UL, ULC, CSFM Listed; FM Approved; Visible Notification Appliances with Synchronized Flash; MEA (NYC) Acceptance* Non - Addressable, SmartSyncTM Operation Compatible • Features -- 1 Visible only (V /O) 24 VDC notification appliances with high output xenon strobe, available for wall or ceiling mount: • UL listed to Standard 1971 • Intensity is selectable as 15, 30, 75, or 110 candela with NMI 4141/%716.1411. visible selection jumper secured behind strobe housing • Operation is compatible with ADA requirements (refer to important installation information on page 3) \ G • Polarized input allows connection to compatible reverse polarity, supervised notification appliance circuit (NAC) Wall Mount Strobes • Regulated circuit design ensures consistent flash output and provides controlled inrush current FIRE \ FIRE • Rugged, high impact, flame retardant thermoplastic housings are available in red or white with clear lens MI" N„, Strobes provide synchronized flash for use with: • 4006, 4008, 4010, and 4100U Series fire alarm control Ceiling Mount Strobes panels with NACs selected to provide strobe synchronization or SmartSync two -wire control** Descri • tion • 4009 IDNetTM NAC Extenders Multi - Candela TrueAlert synchronized strobes • Separate strobe Synchronization Modules that are provide convenient installation to standard electrical available for Class B or Class A operation boxes. The enclosure designs are both impact and vandal • Separate SmartSync Control Modules (SCMs) that resistant and provide a convenient strobe intensity provide Class B or Class A output from conventional selection. Since each model can be selected for intensity NAC inputs output, on -site model inventory is minimized and changes encountered during construction can be easily Strobe housings provides flexible, easy, and accommodated. convenient semi -flush or surface wall mounting: Wall mount strobe housings are a one -piece assembly • Rear of housing does not extend into box (including lens) that mounts to a single or double gang, or • Wall mount strobes easily mount to single gang, double 4" square standard electrical box. The cover can be gang, or 4 -inch square outlet box quickly removed (a tool is required) and covers are • Ceiling mount strobes mount to single gang boxes available separately for color conversion. Wall mount strobe features: Ceiling mount strobes install using standard single gang electrical boxes. Color choice is determined by model • Wiring terminals are accessible from the front of the number. housing providing easy access for installation, inspection, and testing Strobe Intensity Selection • Covers are available separately to convert housing color During installation, a selection plug at the back of the Optional adapters and wire guards: housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow • Wall mount strobe adapters are available to cover background allows the selected intensity to be seen at the surface mounted electrical boxes and to adapt to side of the strobe lens. Simplex 2975 -9145 boxes • UL listed red wire guards are available for wall or Strobe Application Reference ceiling mount strobes Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm Code (NFPA 72), ANSI • This product has been approved by the California State Fire Marshal (CSFM) pursuant to A117.1; the appropriate model building code: BOCA, Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7125-0026:316 for allowable values anchor conditions concerning material presented in ICBO, or SBCCI; and the application guidelines of the this document. It is subject to re- examination, revision, and possible cancellation. Refer to Americans with Disabilities Act (ADA). page 2 for listing status of wire guards. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simple( " Simplex multi- candela SmartSync two-wire horn/strobe appliance operation is protected Time Recorder Co. are the property of Tyco Safety Products Westnrnster. under one a more of the following U.S. Patent Numbers: 5,559,492; 5,622,427; 5,865,527; 5,886,620; 6,281,789; 6,954,137; 7,005,971; and 7,006,003. S4906 -0001 -3 5/2008 Synchronized Strobes SmartSync Control Sources Multiple Strobes. When multiple strobes and their Class B SmartSync two -wire control is available reflections can be seen from one location, synchronized from: flashes reduce the probability of photo- sensitive reactions • 4006, 4008, 4100U, and 4010 Fire Alarm Control as well as the annoyance and possible distraction of Panels (refer to individual product data sheets for more random flashing. These multi - candela strobes are information) • synchronized over a two -wire circuit when connected to compatible NACs, to compatible Synchronized Flash • 4009 IDNet NAC Extender (refer to data sheet Modules, or to SmartSync Control Modules. 54009 - 0002) • SmartSync Control Module (SCM) 4905 - 9938 (refer to SmartSync Two -Wire Control data sheet S4905 - 0003) Some applications desire the audible notification Class A SmartSync two - wire control is available appliances to be capable of being silenced before the from 4100U NACs and from the 4905 -9938 SCM. alarm condition is reset (on- until- silenced) while the Additional SmartSync compatible notification visible notification appliances are kept activated until the appliances include separate horns and combination alarm condition is reset (on- until- reset). SmartSync horn/strobe notification appliances. operation mode provides this function using a single circuit (two -wire operation). Product Selection Multi - Candela Visible Notification Appliances (Strobes) Model Mounting Housing Color "FIRE" Lettering Description 4906 -9101 Wall Red White 4906 -9103 White Red Multi - candela strobe with intensity selectable as: 15, 30, 75, or 110 candela; synchronized flash rate; 4906 -9102 Ceiling Red White SmartSync two -wire control compatible 4906 -9104 g White Red Wall Mount Strobe Adapters Model Description Dimensions 4905 -9937 Red Surface Mount Adapter Skirt; use to cover 1 -1/2" (38 mm) 5 -3/8" H x 5 -1/4" W x 1 -5/8" D 4905 -9940 White deep surface mounted boxes (136 mm x 133 mm x 41 mm) Total depth with strobe = 4 -3/8" (111 mm) 4905 -9931 Red Adapter Plate for mounting to Simplex 2975-9145 box (typically for 8- 5/16" x 5 -3/4" x 0.060" Thick retrofit, may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975 -9145 Red Mounting Box, requires Adapter Plate 4905 -9931 7 -7/8" x 5-1/8" x 2 -3/4" D (200 mm x 130 mm x 70 mm) Ceiling Mount Strobe Adapter Model Description Dimensions 4905 -9910 Surface Mount Adapter Plate; zinc plated; required for mounting to 4 -7/8" x 3-1/8" x 0.060" D handy box; not needed when using 4905 -9926 guard (124 mm x 79 mm x 1.5) Synchronization Modules (refer to data sheet S4905-0003 for additional information) Model Description Dimensions 4905 -9914 Class B Synchronized Flash Module; epoxy encapsulated with 1 -3/8" x 2- 7/16" x 13/16" in /out 18 AWG (0.82 mm) wire leads, rated for 2 A NAC, (35 mm x 62 mm x 20 mm) 4905 -9922 Class A requires 10 mA for power 4905 -9938 SmartSync Control Module with Class B or Class A output; mounts in 4" x 4 -1/8" x 1 -1/4" D 4" (102 mm) square box (102 mm x 105 mm x 32 mm) Replacement Covers and Guards Model Description Dimensions 4905 -9992 Red cover with white "FIRE" lettering 5 -1/8" H x 5" W x 1 -1/2" D For Wall mount strobes 4905 -9993 White cover with red "FIRE" lettering (130 mm x 127 mm x 38 mm) • 4905 -9961' Wall mount 6-1/16" H x 6-1/16" W x 3-1/8" D Red wire guard with mounting plate, compatible with (154 mm x 154 mm x 79 mm) semi -flush or surface mounted boxes 6-1/8" x 4-3/8" x 2 -7/8" deep 4905 -9926' Ceiling mount (156 mm x 111 mm x 73 mm) • UL listed by Space Age Electronics Inc. 2 54906- 0001 -3 5/2008 Strobe S .ecifications Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range UL Listed Rating Regulated 24 VDC; see Note 1 below ULC Listed Rating 20 VDC to 30 VDC per ULC S526 -M878 Flash Rate 1 Hz • Synchronized NAC Loading Up to 35 synchronized strobes maximum per NAC Temperature Range 32° to 122° F (0° to 50° C) Humidity Range 10% to 93 %, non - condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm to 3.31 mm two wires per terminal for in /out wiring Housing Dimensions (with lens) 5-1/8" H x 5" W x 2 -3/4" D (130 mm x 127 mm x 70 mm) Wall Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Strobe Setting (see Note 2 below) 60 mA 94 mA 186 mA 252 mA Mount Reference RMS Currents 18 VDC 53 mA 84 mA 165 mA 224 mA at other voltages 24 VDC 40 mA 63 mA 124 mA 168 mA Housing Dimensions (with lens) 4-3/4" L x 2- 5/16" W x 2 -5/8" D (121 mm x 75 mm x 67 mm) Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Ceiling Strobe Setting (see Note 2 below) 75 mA 125 mA 233 mA 316 mA Mount Reference RMS Currents 18 VDC 67 mA 111 mA 207 mA 281 mA at other voltages 24 VDC 50 mA 83 mA 155 mA 211 mA NOTES: 1. "Regulated 24 VDC" refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired, changes effective May 1, 2004. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the strobe. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. 2. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) Installation Reference, Surface or Semi -Flush Wall Mounting o : Mounting is compatible with I / \ o / \ single gang, double gang, and 1 f 1 4" (102 mm) square boxes, , 1 -1/2" (38 mm) deep, by others r1 _I �p� P X01 _ IMPORTANT! WALL MOUNT II J INSTALLATION HEIGHT REFERENCE Bottom of lens O if Hadn I is either even UP % ' with, or slightly Electrical Wiring access hole � � % � above bottom box outline � . II-e Phil I of compatible \ AMI Wiring terminals 9 1111=rl X16- 0� II boxes r I � Mounting Holes: in 4" square (4) NFPA 72 requires 80" (2.03 m) Q�s. ® �� Single gang (2) that the entire lens minimum �� � -r i l l , Double gang (3) be not less than i° 80" and not greater than 96" above the Transparent housing finished floor and lens assembly Intensity selection 10 • plug, accessible only i 7 from rear of housing; .® F [1 N E factory setting is 15 cd MI Removable cover Strobe intensity (tool required) viewing slot 3 S4906- 0001 -3 5/2008 Ceiling Mount Strobe Installation Reference / Handy box, 1 -1/2" (38 mm) deep Single gang box (Wiremold (RACO 650 or equal) or single gang V5744S) 2.1/4" (57 mm) box, 2 -1/2" (64 mm) deep (RACO 519 • deep, supplied by others or equal) supplied by others Also can be attached to boxes /41 ,y/ mounted to drop ceiling T -bar with clips (ERICO No. 512 or equal) I 0 U 0 4905 -9910 Adapter Plate, required for v ( surface mount with handy box unless using the 4905 -9926 wire guard I I I - 1 _ ■■ _ Ceiling mount strobe II"I' Fl 1 R 1 E II Optional 4905-9926 wire guard I with mounting plate III — — l .! / Strobe intensity r � viewing slot �i Intensity selection plug, accessible only from rear of lens housing; factory setting is 15 cd Wall Mount Installation Reference; Adapter Plate, Guard, and Adapter Skirt Surface Mounting Reference mll 2975 - 9145 Box with Optional Adapter Skirt and Optional Wire Guard o . Surface mount conduit and O box shown for reference t ��._� ^� 4" (102 mm) square aI �' _ _1_1IIIIISH � r ...r 1 box profile, 1-1/2" I, II' I 11111.I.I I II (38 mm) deep — I ME 1= .I.�� I UII 4905 -9961 I . I Wire Guard -': Strobe ` _ f F0 H IIII ^ I 4905 -9931 Adapter Plate �I ' – t Optional Surface Mount Adapter Skirt, O 4905 -9961 Optional Wire Guard 1 -1/2" deep: 4905 -9937, Red; (shown here for reference only, 4905 -9940, White (conduit knockouts 4905 -9931 Adapter Plate can be used on other mounting options) are provided on all four sides) Tyco is a registered trademark of Tyco International Services GMBH and is used under license. Simplex, the Simplex logo. IDNet. TrueAlert, and SmartSync are trademarks of Tyco International Ltd and its affiliates and are used under license. M PA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFP.4). B Simplex Tyco Safety Products Westminster • Westminster, MA • 01441 -0001 • USA S4906-0001-3 5/2008 m www. tycosafetyproducts- usa -wm. com O 2008 Tyco Safety Products Westminster. All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice. [Page Too Large for OCR Processing] [Page Too Large for OCR Processing]