FP -11 FirePrintTM Detector BUILDING DIVISION
Intelligent Fire Detector for MXL, MXL -IQ, and MXLV Control Panels
ENGINEER AND ARCHITECT SPECIFICATIONS
• Most Sophisticated "Detector Intelligence" available today
• Multi- Criteria fire detection for the price of a
photoelectric detector
• FirePrint'M Technology to discriminate between deceptive
phenomena and an actual fire
• Easily programmed to match specific hazard profiles from the
control panel
• Pre -Alarm reporting based on fire profile selected
• Remote sensitivity measurement capability
• System logic activation based on any of three inputs from
detector (smoke, heat or neural network) • • Field cleanable chamber with replaceable chamber
parts available
• Multi -color detector status LED '
• Two-wire operation
• Compatible with Model DPU or FPI -32 field
programmer /tester
• Supports EnviroLINK software based automatic 1 -
environmental compensation
• Backward compatible with older MXL systems
(Rev. 2 and above)
• • Optional fully programmable relay base , audible base, and
duct housing
• O UL Listed, ULC Listed, CSFM, FM, NYMEA •
Ul Approved
•
Introduction
The FP -11 Intelligent Fire Detector provides the life need for cumbersome, unreliable mechanical program -
safety industry with the most highly evolved detection ming methods and reduces installation and service
system available today. The FP -11 utilizes advanced costs by electronically programming and testing the
detection technology that allows the detector to detector prior to installation.
distinguish nonthreatening deceptive phenomena, such
as cigarette smoke, from actual fire hazards, while The FP -11 fire detector is compatible with the MXL
optimizing detection for the area in which it is in- family of control panels including the MXL, MXL -IQ,
stalled. No other detection system available today and MXLV.
offers a higher level of protection or nuisance The FP -11 detector is Underwriters Laboratories and
alarm immunity. The FP -11 uses state -of- the -art Underwriters Laboratories of Canada Listed.
microprocessor circuitry with error check, detector
self- diagnostics and supervision programs.
Description
The FP -11 intelligent fire detector is compatible with The FP 11 is a plug-in, two wire, multi sensor detector
the Siemens Building Technologies, Fire Safety Divi- p g
sion, Model DPU or FPI -32 field programmer /tester, with both photoelectric and thermal inputs and is
which is a compact, portable, menu - driven accessory compatible with the MXL family of control panel
for electronically programming and testing detectors, systems. Each detector consists of a dust resistant,
• easily and reliably. The DPU or FPI -32 eliminates the field cleanable photo chamber, a solid state
CATALOG NUMBER 6175
non - mechanical thermal sensor, microprocessor based evaluating this information with sophisticated
electronics with a low- profile plastic cover and base. mathematical formulas, or algorithms, comparing this
• The FP -11 utilizes state -of- the -art ASIC and surface input to characteristics of both threatening fires and
mount technology for maximum reliability. Every FP -11 deceptive phenomena that would "fool" any ordinary
fire detector is shipped with a protective dust cover. detector. This technology was developed over years of
research-and reviewing the results of over 20 years of
The FP -11 fire detector utilizes an infrared light fire test data in one of the world's most advanced fire
emitting diode (IRLED), and light sensing photodiode. research centers. The results of this research are the
Under normal conditions, light transmitted by the LED mathematical models that form the algorithms used in
is directed away from the photodiode and scattered FirePrint. No other fire detector has this level of
through the smoke chamber in a controlled pattern. intelligence or this amount of research and develop -
The smoke chamber is designed to manage light ment supporting it's design.
dissipation and extraneous reflections from dust
particles or other non -smoke airborne contaminants in The microprocessor's software can identify and
such a way as to maintain stable, consistent detector disregard false input caused by radio frequency (RFI)
operation. When smoke enters the detector chamber, and electromagnetic (EMI) interference, and validates
light emitted from the IRLED is scattered by the all trouble conditions before annunciating or reporting
smoke particles and is received by the photodiode. to the control panel. The FP -11 detector's microproces-
sor uses an integral EEPROM to store the detector's
The FP -11 also utilizes a modern, accurate, shock- address and other critical operating parameters which
resistant thermistor to sense temperature changes. include the assigned program values for alarm and
The "on- board" FirePrint technology allows the trouble thresholds. Communications within the
detector to gather smoke and thermal data, and to detector itself and between the FP -11 and the control
analyze this information in the detector's "neural panel, or with the FPI -32 field programmer /tester, are
network" By comparing data received with the supervised and safeguarded against disruption by
common characteristics of fires, or fire fingerprints, reliable, microprocessor based error checking routines.
the FP -11 can compare these "Fire Prints" to those of Additionally, the microprocessor supervises all
deceptive phenomena that cause other detectors to EEPROM memory locations and provides a high
alarm. The advanced FirePrint technology allows the degree of EEPROM failure fault tolerance.
FP -11 to accurately determine a true fire hazard from
a nonthreatening deceptive phenomena WITHOUT In MXL(V) applications, the FP -11 determines its
needing to use alarm delaying verification and confir- operating status to be normal, in alarm, or in trouble
mation techniques, which can increase the probability depending on the difference between the alarm
of losses due to fire. threshold values stored in the detector's memory and
the detector's latest analog measurement. The
The FP -11 provides the highest level of detector detector then communicates changes in its status to
intelligence available today with a detector /control the control panel.
panel link that allows the user to program the detector
for the specific hazard profile Detectors are optimized In addition, the MXL(V) control panel will sample the
by selecting one of the following applications: value of the FP -11's analog signal over a period of time
in order to determine if those values indicate exces-
• Office /Retail sive buildup in the photo chamber; if so, the MXL(V)
• Lobby will indicate that the particular detector requires
• Computer Room maintenance.
• Dormitory
• Healthcare The FP -11 is listed as a self- testing device. The FP -11's
• Parking Garage visible light emitting diode (LED) flashes green every
• Utility/Transformer Room 4 seconds to indicate it is communicating with the
• Hostile Environment control panel and that it has passed its internal self-
• Precious Storage test. Should the detector sense a fault or failure within
• Air Duct its systems, the LED will flash amber and the detector
• Warehouse /Light Manufacturing will transmit that information to the control panel.
The software does the rest; no guessing on detector A quick visual inspection is sufficient to indicate the
condition of the detector at any time. If more detailed
sensitivities or alarm verification; the control panel information is required, a printed report can be
programs the FP -11 detector for the protected area provided from the MXL panel indicating the status
without hassle and without confirmation delays. and settings assigned to each individual detector.
Once optimized for the hazards in the protected area,
the FP -11 provides the best detection you can buy. When the FP -11 moves to the alarm mode, it will flash
Should the operator or installer forget to program the amber and transmit that information to the control
detector, the FP -11 will revert to a default setting that panel. When the MXL(V) confirms the detectors
allows it to operate as a standard photoelectric or condition, the panel will instruct the FP -11 to flash red
photothermal detector. and to continue flashing until the system is reset at
The FP -11's FirePrint technology monitors input from
the control panel. At that same time, any user defined
both the photo chamber and the thermal sensor,
•
system alarm functions programmed into the system All FP -11 detectors are approved for operation within
are activated. Each FP -11 detector can operate one the UL specified temperature range of 32 to 100
remote alarm indicator, one auxiliary relay, or one degrees F (0 to 38 degrees C).
audible base.
Detector sensitivity, calibration, .and,. identification are Application Data
dynamically supervised by the control panel. Detector Installation of the FP -11 series of fire detectors
sensitivity and pre -alarm levels are a function of the requires a two-wire circuit of 18 AWG (minimum)
application chosen at the control panel and are thermoplastic fixture wire enclosed in conduit, or 18
controlled by the panel. If an alternate, non - FirePrint AWG limited energy, shielded cable without conduit,
mode is selected, then the sensitivity can be changed if permitted by local codes. Field wiring should
from the control panel. conform to local and National Electric Codes and the
The DPU or FPI -32 Program/Test accessory is used to control panel wiring specifications.
program and verify the detector's address. The "T- tapping" is permitted only for Style 4 (Class B)
technician selects the accessory's program mode to wiring.
enter the desired address. The DPU or FPI -32 auto-
matically sets and verifies the address and tests the FP -11 fire detectors can be applied within the maxi -
detector. It also allows the user to change the device mum 30 foot center spacing (900 sq. ft. areas) as
ID from that of an FP -11 to an older detector ID such as referenced in NFPA 72. This applications guideline is
an ILP -1, ILPT -1, ILP -2, ID -60P or ID -60PT to allow for based on ideal conditions, specifically, smooth ceiling
easy replacement of older detectors without the need surfaces, minimal air movement, and no physical
of reprogramming the control panel. obstructions between potential fire sources and the
detector. Do not mount detectors in close proximity
The FPI -32 operates on AC power or rechargeable to ventilation or heating and air conditioning outlets.
batteries, providing flexibility and convenience in Exposed joints or beamed ceilings may also affect safe
programming and testing equipment almost anywhere. spacing limitations for detectors. Should questions
When in the test mode, the DPU or FPI -32 will perform arise regarding detector placement, observe NFPA
a series of diagnostic tests without altering the 72 guidelines.
address or other stored data, allowing technicians to
determine if the detector is operating properly. Good fire protection system engineering and common
sense dictate how and when fire detectors are
The FP -11 fire detector may be installed on the same installed and used. Contact your local Siemens
initiating circuit with IL or ID series detectors (Photo- Building Technologies, Fire Safety Division authorized
electric, thermal, or ionization), MSI series manual sales outlet whenever you need assistance applying
stations, TRI series interfaces, ICP output control FirePrint in unusual applications. Be sure to follow
devices, or CZM series of addressable, conventional NFPA guidelines, UL /ULC approved installation
zone modules. instructions, which are included with every detector,
All FP -11 detectors can be cleaned in the field, when and local codes as for all fire protection equipment.
required, by simply removing the detector cover and
unsnapping the photo chamber. There is also the Dimensions
option of cleaning the interior of the detector with a
clean, soft cloth or brush, or replacing the labyrinth and I 6' Diameter Base
bug screen included in the detector maintenance kit,
model DMK -11. _
The FP -11 uses the low profile surface mounting base,
model DB -11. This base mounts on a 4 -inch octagon,
square, or a single gang electrical box. The base 2. `'
utilizes screw clam p contacts for electrical connections Overall
and self- wiping contacts for increased reliability. The Height
base can be used with the optional LK -11 detector ��'• 1r� ���
" W'
locking kit which contains 50 detector locks and an may
installation tool, to prevent unauthorized removal of
the detector head. The DB -11 base has integral decora-
tive plugs to cover the outer mounting screw holes.
The FP -11 is electrically compatible with existing MXL
detector accessories including relays, remote lamps,
duct housings, and audible bases. With duct housings,
a base adapter and new detector housing cover are
required (order AD -11 UK upgrade kit). To use existing
DB -3S base or audible base, the FP -11 requires a DB-
ADPT base adapter.
Technical Specifications
Current Requirements: Normal 750 pa Alarm 750 pa
Operating Temperature: +32 °F (0 °C) to 100 °F (38 °C)
per UL 268/268A
Humidity: 0 -93% Relative Humidity
Non - Condensing
Ordering Information
Part
Model Description Number
FP-11 Addressable FirePrint Fire Detector 500- 095112
DB -11 Detector Mounting Base for Series 11 500-094151
DB -11E Detector Base (Small) 500- 094151E
AD2 -P Air Duct Housing for use with FP-11, HFR11, HFPO -11, 500- 649706
PE -11
AD2 -XHR Air Duct Housing for use with FP-11, HFR11, HFPO -11 500- 649708
with relay
ADBX -11 Audible Base 500- 096181
DB -X11RS Relay Base for Series 11 Intelligent Detectors 500- 096125
RU -1 Remote (red) alarm indicator- 4' octagon box mount 500- 390673
RU -2 Remote (red) alarm indicator- single gang box mount 500- 390674
LK -11 Base Locking Kit for Series 11 detectors 500- 695350
DMK -11 Series 11 Maint Kit (replacement labyrinth and bug 500- 695338
bug screen)
DB -ADPT Base Adapter to DB-3S Base 500- 094187
In Canada Order:
FP -I1C Addressable FirePrint Are Detector (ULC) 500- 095112C
DB -11C Detector Mounting Base for Series 11 (ULC) 500- 095687
AD -11PC Air Duct Housing (ULC) 500 -095984
DB- X11RSC Relay Base for Series 11 Intelligent Detectors (ULC) 500- 096125C
ADBX -11C Audible Base for Series 11 Intelligent Detector (ULC) 500- 096181C
•
Fire Safety Fire Safety
8 Fernwood Road 2 Kenview Boulevard
Florham Park, NJ 07932 5/06 Brampton, Ontario
Siemens Building Technologies Tel: (973) 593 -2600 10M Canada L6T 5E4
9 9 IeS FAX: (973) 593 -6670 SFS-IG Tel: (905) 799 -9937 May2006
Fire Safety Website: www.sbt.siemens.com /f is Printed in U.S.A. FAX: (905) 799 -9858 Supersedes sheet dated 6/03