Specifications 9 2 o r4L�1a e0( d ,20 -0-0-o co / REC,E1VE SERVICE M �� DIRECTORY '-LIILDINGDIVIalOM Local SimplexGrinnell Service Operations SimplexGrisinell 6305 SW Rosewood St. Lake Oswego, OR 97035 Telephone Number (24- Hours): (503) 683 -9000 Service Supervisor: Willie Olson Service Dispatch: Julie Toney Project Salesman: George Satushek Project Engineer: John LeDoux District Manager: Pete Rudge SIMPLEX WARRANTY 1. Simplex warrants to the Purchaser of new Simplex Products that during the effective period of the warranty such Products shall be free of defects in workmanship and material. This warranty period, for a system or part thereof, shall terminate upon the earlier occurrence of either of the following events: A. The date eighteen months following shipment, or B. The date one year following the final hook -up operation and beneficial use of all or any part of the system. 2. Simplex's sole responsibility under this warranty shall be to repair, adjust or replace at its option, any product which fails during this period provided Purchaser has promptly reported such failure to Simplex in writing. All replaced Products or parts shall become Simplex's property. Services provided under this warranty will be performed during the period of 8:00 a.m. to 5:00 p.m., local time, Monday through Friday, excluding locally observed Simplex Holidays. Purchaser agrees to provide full and free access to the equipment to authorized Simplex employees and any ladders and/or scaffolding, if required. 3. This warranty is contingent on the proper installation and use of the Products. Such warranty will not apply if adjustment, repair or parts replacement is required because of accident, neglect, misuse, user programming errors, failure of electrical power, air conditioning, or humidity control, construction dust, damaging, foreign substances, transportation or causes other than manufacturing defect. Replacement parts provided under warranty of products may contain used parts which are equivalent to new parts when used. Replacement parts will be warranted only for the balance of the equipment warranty. Simplex agrees to continue to honor all of the unexpired express warranties specified above on defective equipment after transfer of the equipment to purchaser's customer, provided purchaser's customer assumes the purchaser's obligations specified above. 4. This warranty does not include: A. Time and material charges for service outside of Simplex's normal business hours. B. Time and material charges for program and/or label changes. C. Time and material charges for failures due to external causes (see paragraph #3). D. Electrical work external to the equipment supplied by Simplex or maintenance of accessories, alterations, attachments or other devices not furnished by Simplex. E. Coverage of equipment classed as water flow monitoring, control device installed in or on water piping. F. Service requested for any reason other than those related in current time and materials then in effect, paragraph two of the aforementioned items. G. Except for the express warranties stated herein, Simplex disclaims all warranties of merchantability and fitness for a particular purpose, and the stated warranties are in lieu of all obligations or liabilities on the part of Simplex arising out of or in connection with the performance of products. The seller shall not be liable for any direct, incidental or consequential loss of damage to the purchaser or user of this equipment arising out of the failure of the equipment to operate in excess of the purchase price of said equipment. Simplex makes no warranty and no warranty shall be deemed to exist, that purchaser holds the goods free of the claim of any third person by way of patent infringement or the like. DEFECTIVE PERIPHERALS If the Technical Representative and /or the Sales Representative finds that prior to system acceptance that a component is defective, that component must be replaced by the warranty replacement procedure. These defective components should then be returned to Headquarters for return to the manufacturer for up- grading. After the Technician has checked out the complete Simplex system, he will provide the contractor with an "Inspection Report" of the system test. The owner's representative should be present at this time for instruction in the proper operation of the system. • Multi- Application Peripherals 0 ® SII'1'1plex and Accessories Non -Coded Manual Stations UL Listed, CSFM and 2099 Series Single and FM Approved Double Action Operation FEATURES • Single action models ( . • Double action models available as: – Breakglass 1 PU DOWN – Push Type MUNI • Institutional model I – Key operated only ,F.,-,-..-:.. o -_) • Pull lever protrudes when alarmed I ( BREAGLASS • Tamper resistant reset key lock: Single Action Station < – Keyed same as fire alarm cabinet ,' - _ 1 • Pre - signal and annunciator contact options �. 1 ., • Local alarm cover option ®; , ;ry,,� • • Surface, flush, or semi -flush mounting f } –� O' _ • Complies with ADA requirements � PUSH Double Action I PULL DOJvm Station (Breakglass) I OPERATION I Single Action Stations require a firm downward pull to I activate the alarm switch. Completing the action breaks � – an internal plastic break -rod (visible below the pull (-_: ±,7•.;:::) . lever). The pull lever latches into the alarm position and • '111',:f-• • r • remains extended out of the cover to provide a visible -- indication of which station was alarmed. Double Action * Station (Push Type) Double Action Stations (Breakglass) require the KEY operator to strike the front mounted hammer to break • OPERATED • ' the glass and expose the recessed pull lever. The pull ONLY lever then operates as a single action station. - . Double Action Stations (Push Type) require that a . H I = "':.:,, • spring loaded interference plate (marked PUSH) be — pushed back to access the pull lever of the single Sin le Action Station • action station. With Institutional ' FULL DOWN Institutional Stations are designed to activate by key Cover operation only. This allows access for manual alarms to be initiated by authorized personnel. Operation requires key insertion and opening of the station cover. t'L. Pre - Signal Option activates when the lever is pulled. General alarm initiation requires a key to activate a Local Fire Alarm keyswitch located behind the pull lever. Cover Option Station Reset requires the use of a key to reset the manual station lever and deactivate the alarm switch. • These products nave been approved by the California State Fire Marshal (CSFM) If the break -rod is used, it must be replaced. pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7150 - 0026:175 for allowable values and/or conditions concerning material presented in Testing requires physical activation of the pull lever this document. It is subject to re- examination. revision. and possible cancellation. Additional listings may be applicable, contact Simplex for the latest status. Refer to data (except for Institutional stations). sheet S2099 -0009 for stations specifically intended for use in New York City. ULC listed stations are documented separately, contact Simplex for assistance. © 2000 Simplex Time Recorder Co. All rights reserved. S2099 0007 - 6/00 APPLICATIONS Refer to NFPA 72, the National Fire Alarm Code, distance not more than 200 ft (61 m) to the nearest (reference section 5 -9), and all applicable local codes station from any point in the building. When manual for complete requirements for manual stations. The station coverage appears limited in any way, additional following summarizes the basic requirements. stations should be installed. Stations shall be located in the normal path of exit and Construction. Covers and pull levers are constructed distributed in the protected area such that they are of chip resistant and dirt resistant, high impact Lexan unobstructed and readily accessible. polycarbonate. Covers are red with white lettering and Mounting shall be with the operable part not less than pull levers are white with red lettering. 31/2 ft (1.1 m) and not more than 4 1/2 ft (1.37 m) ENVIRONMENTAL SPECIFICATIONS above floor level. At least one station shall be provided on each floor. Temperature Range 32° to 140° F (0° to 60° C) Additional stations shall be provided to obtain a travel Humidity Range up to 90% RH at 90° F (32° C) NON - ADDRESSABLE MANUAL STATION FEATURE SELECTION CHART (see note 3 for addressable station reference) Single. Action' Models pre,Sl Annunciator ::' Annunciator "Local -Alarm ~Institutional ' ; Mountmg (General Alarm) :. igna •Contacts N.O. `Contacts N:C Cover ,. ,,Cover , ? �, a Note's,,,.,, 2099 -9754 1 2099 -9101 ✓ 2099 -9102 ✓ 2 2099 -9107 ✓ ✓ 2099 -9755 ✓ 1 • • 2099 -9762 ✓ 1 • Double- Action., _ • Annunciator Annunciator Mounting • Models `Break- Glass ". "Push y . Pre Signal .Contacts N O Contacts N. Notes ` 2099 -9103 ✓ 1 2099 -9104 ✓ ✓ 2099 -9105 ✓ ✓ 2 2099 -9108 ✓ ✓ ✓ 2099 -9756 ✓ 1 • 2099 -9757 ✓ ✓ 2099 -9758 ✓ ✓ 2 • 2099 -9759 ✓ ✓ ✓ ACCESSORIES :Model, Description 2099 -9803 Replacement breakglass (standard, English) 2099 -9804 Replacement break -rod 2099 -9819 Flush adapter kit, black (refer to page 4) 2099 -9820 Flush adapter kit, beige (refer to page 4) 2099 -9822 Replacement retaining clip for breakglass 2099 -9828 Institutional cover kit 2975 -9178 Red, surface mount box, sheet metal, 5 3/16" H x 4" W x 2 3/16" D (127 mm x 102 mm x 56 mm) 2975 -9022 Red, cast aluminum surface mount box, 5" H x 3 7/8" W x 2 3/16" D (127 mm x 98 mm x 56 mm) NOTES: 1. These models can be semi -flush mounted using a standard single gang 2 1/2" (64 mm) deep switch box. DO NOT RECESS BOX, mount box flush or with 1/16" (2 mm) maximum protrusion. These models can also be surface mounted on a Wiremold box model number V5744S, 4 5/8" H x 2 7/8" W x 2 1/4" D (117 mm x 73 mm x 57 mm). 2. For surface mount, these models require 2975 -9178 or 2099 -9022 boxes. For semi -flush mount, these models require a 4" (102 mm) square box with a single gang cover plate (see diagram on page 3). 3. For information on Simplex addressable manual stations, refer to data sheet S2190 -0012 for MAPNET II addressable stations and data sheet S4099 -0001 for IDNetTM addressable stations. S2099- 0007 -14 6/00 page 2 MOUNTING INFORMATION Refer to installation instructions 574 -656 (PER -21 -502) for additional information. SURFACE MOUNTING Knockouts located 4" (102 mm) top and bottom 2975 -9178 Box kill=111r _______ FIRE CD ALARM 53/16" (132 mm) Station cover 5„ PULL DOWN hinges open for (127 mm) installation access - 2 3/16" (56 mm) 2975 -9178 Box 0 Simplex 1 "(25.4 mm) l '* -- 3 3/4" (95 mm) � >"" Side View, Surface Mounting SEMI -FLUSH MOUNTING, 4" BOX (refer to selection chart for requirements) 4" (102 mm) square box, 2 1/8" (54 mm) minimum Mount flush or with depth RACO #231 or equal (supplied separately) 1/16" (2 mm) maximum extension DO DO NOT RECESS r � \ (� \ O Electrical box o fa ■... ,_ ■,' i o Station side view 0 FIRE ® ALARM t ® U = o III PULL DOWN C ■ Single gang cover plate, 3/4" (19 / \ Single gang cover • mm) extension, RACO #773 or Wall plate DSim equal (supplied separately) P surface --------- Side View, Semi -Flush Mounting S2099- 0007 -14 6/00 page 3 FLUSH MOUNTING REFERENCE INFORMATION Flush mount adapter kit Front View 2099 -9819, Black Side View 2099 -9820, Beige t a Box must be recessed into wall 1" to 1 1/8" (25.4 mm to 29 mm) 1 \ ,Ji ` 'S :i al: .4. J!i,A �.4 t' : . r; � F t 2 il ..,.;::.?''',.•4 ;i .4 0 (203 mm) a i a, • -• • ! .p , `- o ,: {;: « :y . 'm • ;: , ` Hole cutout must be a : j i"`''"!'+ l � : PULL DOWN minimum of 6" H b 5° W . O `,tr l (152 mm by 127 mm) �: , 3 i = 6" (152 44 'x: ":'J ' I` ;.: r mm) ' ?:�4. .., i. >:i o 0 4 11/16" (119 mm) square box, 2 1/8" (54 mm) minimum Wall depth (by others) -4 4 3/4" (121 mm) -► surface ` l'. 6 3/4' (171 mm) Simplex, the Simplex logo, MAPNET, and IDNet are either trademarks or registered trademarks of Simplex Time Recorder Co. in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). Lexan is a registered trademark of General Electric Co. S2099- 0007 -14 6 /00 a5Ifl1pleX Westminster, Massachusetts 01441 -0001 U. S. A. Offices and Representatives Throughout the World Visit us on the world wide web at www.simplexnet.com All specifications and other information shown were current as of printing and are subject to change without notice. Simplex TrueAlarm Smoke Detectors UL, ULC Listed; FM, CSFM, TrueAlarm Photoelectric Smoke Detectors and MEA (NYC) Approved* for Two -Wire and Four -Wire Bases Features • • Photoelectric smoke detector with on -board t : • TrueAlarm sensitivity drift compensation UL listed to Standard 268 .: . Functional chamber enclosure: MEI IME1. = =. 1 'k: !'I ®11i.1M • Louvered design enhances smoke capture by directing flow to chamber • Entrance areas are minimally visible when ceiling mounted — 4098 -9601 TrueAlarm Photoelectric Detector Mounted in Base Multi- function indicator LED indicates normal and alarm conditions Magnetically operated functional test: • initiates alarm and verifies performance • Identifies general sensitivity status using detector S s ecifications LED Voltage 15 to 32 VDC from Fire Alarm Control Models available in two sensitivity settings: Panel IDC • 4098 - 9601, Standard Sensitivity, nominal 2.8 %/ft Standby Current 100 µA @ 24 VDC obscuration Up to 86 mA maximum, exact current is • 4098 Special Application Sensitivity, Operation Current, 2 -Wire determined by alarm current limiting of P PP ty� Operation connected IDC nominal 3.5°/0/ft obscuration Alarm Available base options: Op at on rent, 4-Wire 24 mA typical @ 24 VDC • Bases for 2 - wire or 4 - wire operation Auxiliary Relay Ratings Refer to page 2 under Product Selection • Auxiliary alarm relay output Air Velocity Range 0 -2000 ft/min (0 -610 m /min) Optional remote alarm indicating LED UL Listed Temp. Range 32° to 100° F (0° to 38° C) Operating Temp. Range 15° to 122° F ( -9° to + 50° C) Descri • tion Humidity Range 10% to 95% RH from 32° to 122° F (0° to 50° C) non - condensing Simplex TrueAlarm photoelectric detectors Color Frost White • provide many of the proven TrueAlarm analog sensing 4 -7/8" Dia. x 1 -7/8" H, mounted in base features for applications where detectors are connected to Dimensions (124 mm x 48 mm); refer to page 3 for conventional 2 -wire or 4 -wire initiating device circuits detail (IDCs). Each TrueAlarm detector has an on -board microprocessor that evaluates its photoelectric light scattering chamber activity and makes an intelligent decision based on light obscuration history as to whether an alarm condition is present. TrueAlarm detectors are packaged in a patented ULC listed models are designated with a'C'suffix such as 4098-9601C. This product has p g p been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of housing that minimizes the visibility of the air intake the California Health and Safety Code. See CSFM Listing 7272 -0026:219 for allowable louvers from the normal viewing locations while values andlor conditions concerning material presented in this document. It is subject to re- examination, revision, and possible cancellation. Accepted for use - City of New York maintaining a high performance smoke capture ability Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your Bases are available for remote alarm LED indicator local Simplex product supplier for the latest status. connections and auxiliary relay outputs. t TrueAlarm smoke detector operation is protected by one or more of the following U.S. Patents: 5,155468; 5,173,683: 5,400,014; 5543,777; 5,710,541; D383,407; D388,352; D392,573. S4098- 0015 -5 10/02 • TrueAlarm Smoke Detector Features Intelligent Data Evaluation. Conventional smoke directly into alarm with the magnetic test. If there is an detectors will typically drift toward being too sensitive off - normal condition, the LED pulses first to indicate the due to the accumulation of dust and dirt. With TrueAlarm condition and then goes into alarm. (See page 3.) analog detection, data from the photoelectric chamber is Application Reference monitored and analyzed at the detector to provide a continuously shifting reference point. Detector Locations. Locations should be determined Drift Compensation. The data evaluation and its only after careful consideration of the physical layout and contents of the area to be protected. Refer to NFPA 72, shifting reference point provide a software filtering the National Fire Alarm Code. On smooth ceilings, process that compensates for environmental factors (dust, smoke detector spacing of 30 ft (9.1 m) may be used as a dirt, etc.) and component aging, establishing an accurate guide. For detailed installation information, refer to 4098 reference for evaluating new activity. With this filtering, Detectors, Sensors, and Bases Application Manual the resulting drift compensation provides a significant (574 -709). reduction in the probability of false or nuisance alarms caused by shifts in sensitivity – either up or down. Sensitivity Selection. The 4098 -9601 standard sensitivity detector is recommended for most applications. Magnetic Test Information. Status information is When a special application for a reduced sensitivity available by performing the magnetic test and observing detector is required, the 4098 -9605 should be considered. the detector LED pulses. The LED will normally go Consult your local Simplex product supplier for assistance in determining the proper selection. Product Selection Smoke Detectors Model Description Nominal Sensitivity Compatibility —> 4098 -9601 2.8 % /ft (standard) Compatible with bases: 4098 -9788, 4098 -9682, and TrueAlarm Photoelectric Detector 4098 -9605 3.5 % /ft 4098 -9683 Compatible Bases Model Description Details* - -� 4098 -9788 2 -Wire Base with connections for IDC and LED connections are screw terminals for in /out wiring, Remote Alarm LED Indicator 18 to 14 AWG 4 -Wire Base with Auxiliary Alarm Relay Ratings, Single Form "C ", For Suppressed Loads: Relay Contacts and connections for Power limited, 3 A @ 28 VDC; Non -power limited, 3 A @ 120 VAC 4098 -9682 Remote LED Alarm Indicator Wiring Connections (In /Out where required): NOTE: Requires external 24 VDC for Relay contacts and IDC wiring, color coded 18 AWG leads; operation LED wiring, screw terminals for 18 to 14 AWG 2 -Wire Base with Auxiliary Alarm Relay Ratings, Dual Form "C ", For Suppressed Loads: Relay & connections for Remote LED Power limited, 1 A @ 28 VDC; Non -power limited, 1/2 A @ 120 VAC Indicator 4098 -9683 Wiring Connections (In /Out where required): NOTE: Must be connected as the only device on the IDC to ensure relay Relay contacts and IDC ( -), color coded 18 AWG leads; operation. IDC ( +) and LED wiring, screw terminals for 18 to 14 AWG Detector Accessories Model Description Details* Required for mounting to surface mounted 4" (102 mm) square or 4" octagonal boxes, and to 4" square flush mounted boxes 4098 -9832 Adapter Plate May be used when retrofitting existing bases Compatible with detector bases 4098 -9788, -9682, & -9683 4098 -9830 Remote LED Indicator Mounted on single gang stainless steel plate 2098 -9739 Encapsulated Dimensions: 2 -1/2" x 1 -1/2" x 1" Required for 4 -wire circuits using 24 VDC (64 mm x 38 mm x 25.4 mm) 4098 -9682 base, one per circuit; select End-of -Line Rela Mounted on single gang mounting type as required; wiring is 2098 -9735 Plate Mounted stainless steel plate color coded 18 AWG wire leads * Refer to pages 3 and 4 for dimensions and additional mounting details; 18 AWG = 0.82 mm 14 AWG = 2.08 mm 2 S4098- 0015 -5 10/02 • • Detector Status. LED Indications LED Indication Status Pulses approximately every 4 seconds Normal Steady On Alarm LED Response to Magnetic Test * LED Indication Followed By Status Action LED turns ON Alarm is initiated Normal sensitivity is within None compensation range LED pulses quickly, More sensitive, out of normal 6 times in 3 seconds, Alarm is initiated then turns ON compensation range Cleaning or other service is required LED pulses slowly, Alarm is initiated Less sensitive, out of normal 4 times in 8 seconds, compensation range then turns ON Does not initiate Alarm Detector is malfunctioning Service is required * Testing requires placing a magnet at the designated location on the detector cover for 4 seconds. Refer to Application Manual 574 -709 for further test and maintenance information. Dimensions and Reference Information 1/4" (6.4 Imm) 6 -3/8" (162 mm) 4098 -9832 Adapter Plate Fe 4 -7/8" (124 mm) r • NM:INEPT • Base height 1 -7/8" 11/16" MEM I�•iii (48 mm) (17 mm) LED Status Indicator (with clear lens) 4098 -9601 & -9605 Dimensions Mounted on Base i ALARM 0 Simplex 4098 -9830 Remote LED Indicator (not to scale) 3 S4098-0015 -5 10/02 Mountin•'Information • (Electrical boxes are supplied by others.) . Electrical Box Requirements: Without relay (base 4098 - 9788): 4" octagonal or 4" square, 1 -1/2" deep Single gang, 2" deep With relay (bases 4098 -9682 and 4098 - 9683): 4" octagonal, 1 -1/2" deep, with 1 -1/2" extension ring 4" square, 1 -1/2" deep, with 1 -1/2" extension ring Surface mount reference ,. .. 4 "(102 mm) ---..,, ��4 "(102 mm) square box - + 0 __ 0 - - - -- octagonal box -- I - - - -- 1-1/2" (38 mm) Flush mount reference, mount even with final minimum box depth surface, or with up to 1/4" (6.4 mm) maximum recess 4098 -9832 Adapter Plate, reauired for mounting to surface mounted boxes and to 4" square flush mount boxes 1 i �i 4098 -9682 and 4098 -9683 include a relay module that mounts in base electrical box aVI -...°.1.".- 0 I Smoke Detector Bases 4098 -9788, 9682, & -9683 =W ate sImoss.d iii 4098 -9601, -9605 Smoke Detector Teen. Simpler. the Simpler logo, and TrueAlarm are trademarks of Tyco International Services AG or its affiliates in the U.S. and /or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). m SI1 F» X TEPG -US • 91 Technology Drive • Westminster, Massachusetts • 01441 -0001 • USA S4098- 0015 -5 10/02 e) 2002 TEPG -US (a Tern company). All rights reserved. All specifications and other information www.tepg.corn shown were current as of document revision date and are subject to change without notice. Simplex TrueAlert Multi - Candela Notification Appliances UL, ULC Listed; FM Visible Notification Appliances with Synchronized Flash; and CSFM Approved* Non - Addressable, SmartSyncTM Operation Compatible Features Visible only (V /O) 24 VDC notification appliances with high output xenon strobe, available for wall or ceiling mount: • UL listed to Standard 1971 ' _ • Intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured behind strobe housing • Operation is compatible with ADA requirements (refer to important installation information on page 3) • Polarized input allows connection to compatible reverse polarity, supervised notification appliance circuit (NAC) Wall Mount Strobes • Regulated circuit design ensures consistent flash output and provides controlled inrush current I F I I R E I • Rugged, high impact, flame retardant thermoplastic �. . housings are available in red or white with clear lens I %'! I ,mil ;--1 Strobes provide synchronized flash for use with: • 4010 Series and 4100U Series fire alarm control panels Ceiling Mount Strobes with NACs selected to provide strobe synchronization or SmartSync two -wire control ** Descri • tion • 4009 IDNetTM NAC Extenders Multi Candela TrueAlert synchronized strobes • Separate strobe Synchronization Modules that are provide convenient installation to standard electrical available for Class B or Class A operation boxes. The enclosure designs are both impact and vandal • Separate SmartSync Control Modules (SCMs) that resistant and provide a convenient strobe intensity provide Class B or Class A output from conventional selection. Since each model can be selected for intensity NAC inputs output, on -site model inventory is minimized and changes encountered during construction can be easily Strobe housings provides flexible, easy, and accommodated. convenient semi -flush or surface wall mounting: Wall mount strobe housings are a one - piece assembly • Rear of housing does not extend into box (including lens) that mounts to a single or double gang, or • Wall mount strobes easily mount to single gang, double 4" square standard electrical box. The cover can be gang, or 4 -inch square outlet box quickly removed (a tool is required) and covers are • Ceiling mount strobes mount to single gang boxes available separately for color conversion. Wall mount strobe features: Ceiling mount strobes install using standard single gang electrical boxes. Color choice is determined by model • Wiring terminals are accessible from the front of the number. housing providing easy access for installation, inspection, and testing Strobe Intensity Selection • Covers are available separately to convert housing color During installation, a selection plug at the back of the Optional adapters and wire guards: housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow • Wall mount strobe adapters are available to cover background allows the selected intensity to be seen at the surface mounted electrical boxes and to adapt to side of the strobe lens. Simplex 2975 -9145 boxes • UL listed red wire guards are available for wall or Strobe Application Reference ceiling mount strobes Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications This product has been approved by the California State Fire Marshal (CSFM) pursuant to of: the National Fire Alarm Code (NFPA 72), ANSI Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7125-0026:316 for allowable values and /or conditions concerning material presented in A117.1; the appropriate model building code: BOCA, this document. It is subject to re- examination, revision, and possible cancellation. This ICBO, or SBCC1; and the application guidelines of the product was not approved by (NYC) as of document revision date. Refer to page 2 for Americans with Disabilities Act (ADA). listing status of wire guards. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time " Two-wire strobe synchronization operation is protected by U.S. Patent No. 5,559,492; Recorder Co. are the property of Tyco Safety Products Westminster. SmartSync horn/strobe operation is protected under U.S. Patent No. 6,281,789: strobe designs are also protected under U.S. Patent Nos. 5,886.620; 5.622,427: and 5.865,527. S4906- 0001 -1 8/2004 • Synchronized Strobes Smart Sync Control. Sources Multiple Strobes. When multiple strobes and their Class B Smart Sync two -wire control is available reflections can be seen from one location, synchronized from: flashes reduce the probability of photo- sensitive reactions • 4100U and 4010 Fire Alarm Control Panels; 4010 as well as the annoyance and possible distraction of panels require operating software Revision 2.X or random flashing. These multi- candela strobes are higher (refer to data sheet S4010-0001 for details; refer synchronized over a two -wire circuit when connected to to data sheet S4100 -0031 for basic 4100U information) compatible NACs, to compatible Synchronized Flash • 4009 IDNet NAC Extender, models 4009 -9201 and Modules, or to Smart Sync Control Modules. 4009 -9301 (refer to data sheet S4009-0002) Smart Sync Two - Wire Control • Smart Sync Control Module (SCM) 4905 -9938, converts separate conventional horn and strobe NAC Some applications desire the audible notification inputs into a Smart Sync NAC output; up to eight SCMs appliances to be capable of being silenced before the can be synchronized to each other alarm condition is reset (on- until - silenced) while the visible notification appliances are kept activated until the Class A SmartSync two -wire control is available alarm condition is reset (on- until- reset). SmartSync from 4100U NACs and from the 4905 -9938 SCM. operation mode provides this function using a single Additional SmartSync compatible notification circuit (two -wire operation). appliances include separate horns and combination horn/strobe notification appliances. Product Selection Multi - Candela Visible Notification Appliances (Strobes) Model Mounting Housing Color "FIRE" Lettering Description 4906 -9101 Wall Red White 4906 -9103 White Red Multi- candela strobe with intensity selectable as: 15, 30, 75, or 110 candela; synchronized flash rate; 4906-9102 Ceiling Red White SmartSync two -wire control compatible 4906 -9104 g White Red Wall Mount Strobe Adapters Model Description Dimensions 4905 -9937 Red Surface Mount Adapter Skirt; use to cover 1 -1/2" (38 mm) 5-3/8" H x 5 -1/4" W x 1 -5/8" D deep surface mounted boxes (136 mm x 133 mm x 41 mm) 4905-9940 White Total depth with strobe = 4 -3/8" (111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975 -9145 box (typically for 8 -5/16" x 5 -3/4" x 0.060" Thick retrofit, may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975 -9145 Red Mounting Box, requires Adapter Plate 4905 -9931 7 -7/8" x 5 -1/8" x 2-3/4" D (200 mm x 130 mm x 70 mm) Ceiling Mount Strobe Adapter Model Description Dimensions 4905 9910 Surface Mount Adapter Plate; zinc plated; required for mounting to 4 -7/8" x 3 -1/8" x 0.060" D handy box; not needed when using 4905 -9926 guard (124 mm x 79 mm x 1.5) Synchronization Modules (refer to data sheet S4905 -0003 for additional information) Model Description Dimensions 4905 -9914 Class B Synchronized Flash Module; epoxy encapsulated with 1-3/8" x 2-7/16" x 13/16" in /out 18 AWG (0.82 mm) wire leads, rated for 2 A NAC, (35 mm x 62 mm x 20 mm) 4905 -9922 Class A requires 10 mA for power 4905 9938 SmartSync Control Module with Class B or Class A output; mounts in 4" x 4 -1/8" x 1 -1/4" D 4" (102 mm) square box (102 mm x 105 mm x 32 mm) Replacement Covers and Guards Model Description Dimensions 4905 -9992 Red cover with white "FIRE" lettering 5 -1/8" H x 5"W x 1 -1/2" D For Wall mount strobes 4905 -9993 White cover with red "FIRE" lettering ( 130 mm x 127 mm x 38 mm) 4905-9961' Wall mount 6- 1/16" H x 6 -1/16" W x 3 -1/8" D Red wire guard with mounting plate, compatible with (154 mm x 154 mm x 79 mm) 4905 -9926' Ceiling mount semi -flush or surface mounted boxes 6 -1/8" x 4 -3/8" x 2 -7/8" deep (156 mm x 111 mmx73mm) • UL listed by Space Age Electronics Inc. 2 S4906- 0001 -1 8/2004 Strobe S • ecifications Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range UL Listed Rating Regulated 24 VDC; see Note 1 below ULC Listed Rating 20 VDC to 30 VDC per ULC S526 -M878 Flash Rate 1 Hz Synchronized NAC Loading Up to 35 synchronized strobes maximum per NAC Temperature Range 32° to 122° F (0° to 50° C) Humidity Range 10% to 93 %, non - condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm to 3.31 mm two wires per terminal for in /out wiring Housing Dimensions (with lens) 5 -1/8" H x 5" W x 2 -3/4" D (130 mm x 127 mm x 70 mm) Wall Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Strobe Setting (see Note 2 below) 60 mA 94 mA 186 mA 252 mA Mount Reference RMS Currents 18 VDC 55 mA 85 mA 169 mA 226 mA at other voltages 24 VDC 41 mA 63 mA 123 mA 164 mA Housing Dimensions (with lens) 4 -3/4" L x 2- 5/16" W x 2 -5/8" D (121 mm x 75 mm x 67 mm) Ceiling Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Strobe Setting (see Note 2 below) 75 mA 125 mA 233 mA 316 mA Mount Reference RMS Currents 18 VDC 64 mA 102 mA 199 mA 266 mA at other voltages 24 VDC 49 mA 76 mA 146 mA 195 mA NOTES: 1. "Regulated 24 VDC" refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired, changes effective May 1, 2004. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the strobe. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. 2. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) . Installation Reference, Surface or Semi -Flush Wall Mounting _ Mounting is compatible with ( 0 \ o ( 1: \ single gang, double gang, and 1 I 4" (102 mm) square boxes, 1 -1/2" (38 mm) deep, by others i ii ' IMPORTANT! WALL MOUNT • INSTALLATION HEIGHT REFERENCE T Bottom of lens _ Q O iit either even _ w ith, or slightly Electrical Wiring access hole i x� � , above bottom I box outline fri! ® /►mil © of compatible tt lls\ W iring terminals II .i � Ialu i 1!_ � � O� p�� 1 r ^_ `` - ,Ili Mounting Holes: srammmomiiiimmimmammw. I►u 9 — I 4" square (4) NFPA 72 requires 80" (2.03 m) � °0p®° ® Single gang (2) that the entire lens minimum ��� I Double gang (3) be not less than ill r 80" and not greater than 96" above the Transparent housing finished floor and lens assembly Intensity selection plug, accessible only . from rear of housing; TM ® F El N E factory setting is 15 cd dill Removable cover Strobe intensity (tool required) viewing slot 3 S4906- 0001 -1 8/2004 Ceiling Mount - Strobe Installation;Reference; Handy box, 1 -1/2" (38 mm) deep Single gang box (Wiremold (RACO 650 or equal) or single gang V5744S) 2 -1/4" (57 mm) box, 2 -1/2" (64 mm) deep (RACO 519 deep, supplied by others or equal) supplied by others Also can be attached to boxes ,( 4/ mounted to drop ceiling T -bar with clips (ERICO No. 512 or equal) 000 4905 -9910 Adapter Plate, required for surface mount with handy box unless using the 4905 -9926 wire guard • . I- 1 I -I Ceiling mount strobe 1I[1i F� Optional 4905 -9926 wire guard IF1 — FIFO o IL I1,li II with mounting plate IN t,: ! , Strobe intensity �� viewing slot Intensity selection plug, to i accessible only from rear of lens I housing; factory setting is 15 cd i ' Wall Mount Installation Reference; Adapter :Plate, Guard; and Adapter :Skirt Surface Mounting Reference 2975 - 9145 Box with Optional Adapter Skirt and Optional Wire Guard --n Surface mount conduit and 0 box shown for reference II l = - - - - i 4 " (10 2 m m) square UI� , ., III I•IuI�I.�II�II11, ._... box profile, 1-1/2" I/111111I.11111 , II (38 mm) deep i— 111 : . • t ' IIII>� I %t � Optional I O O I 4905 -9961 ist NW . I Wire Guard 1'4u:1Ji t S trobe `■ n F O L l I II � ^ R l' 4905 -9931 Adapter Plate l` ' I - Optional Surface Mount Adapter Skirt, O 4905 -9961 Optional Wire Guard 1 -1/2" deep: 4905 -9937, Red; - (shown here for reference only, 4905 -9940, White (conduit knockouts 4905 -9931 Adapter Plate can be used on other mounting options) are provided on all four sides) Tyco. Simplex, the Simpler logo. IDNet. TrueAlert, and Sntar!Svnc are trademarks of Tyco International AG or its affiliates in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA I. Simplex Tyco Safety Products Westminster • Westminster, MA • 01441 -0001 • USA S4906-0001-1 8/2004 c www. tycosafetyproducts- use -wm. coo C 2004 Tyro Safety Products IVestminster. All rights reserved. All specifications and other information shown were current as ofdocvment revision date and are. subject to change without notice. • 5 e Simplex TrueA /ert Multi - Candela Notification Appliances UL, ULC Listed; FM Visible Notification Appliances with Horn and Synchronized and CSFM Approved* Flash; Non - Addressable, SmartSyncTM Operation Compatible w r Features cif. __ „P , Audible /visIble (NV) notification appliances with �4' n"... � Q S efficient electronic horn and high output xenon . - • strobe, available for wall or ceiling mount • • Operation is compatible with ADA requirements (refer - - _ to important installation information on page 3) ° • Rugged, high impact, flame retardant thermoplastic - - - -- housings are available in red or white with clear lens � �� Operates over a two -wire SmartSync circuit to provide: C • Horns that are controlled separately from strobes on the same two-wire circuit - - ' — • "On- until - silenced" and "on- until- reset" operation on l 11 I ii ! •�% the same two -wire pair E I . ` • Horn control that can be selected to be temporal coded, 0_______F: 11 R march time coded, or on continuously - jt,.- ;..-T' -1 1' appliances on the same circuit operating at a ;�',.I t;l PP P g ;�.j;; ,, � • Strobe a synchronized 1 Hz flash rate `.y - - ?i = • Class B (Style Y) operation requires connection to a compatible SmartSync NAC or to SmartSync Control Wall and Ceiling Mount ANs Module (SCM) 4905 -9938 Descri •tion • Class A (Style Z) operation when connected to the 4905 -9938 SCM or with 4100U series fire alarm control Multi- Candela TrueAlert A/Vs with horn and panel NACs synchronized strobe provide convenient installation to standard electrical boxes. The enclosure designs are Wall mount A/Vs features: both impact and vandal resistant and provide a convenient • Wiring terminals are accessible from the front of the strobe intensity selection. Since each model can be housing providing easy access for installation, selected for strobe intensity output, on -site model inspection, and testing inventory is minimized and changes encountered during • Covers are available separately to convert housing color construction can be easily accommodated. Optional adapters and wire guards: Wall mount A/V housings are a one -piece assembly (including lens) that mounts to a single or double gang, or • Wall mount AN adapters are available to cover surface 4" square standard electrical box. The cover can be mounted electrical boxes and to adapt to Simplex® quickly removed (a tool is required) and covers are 2975 -9145 boxes available separately for color conversion. • UL listed red wire guards are available for wall or ceiling mount ANs Ceiling mount ANs install using standard 4" electrical boxes. Color choice is determined by model number. Visible notification appliance (strobe): Strobe Intensity Selection • 24 VDC xenon strobe; intensity is selectable as 15, 30. • 75, or 110 candela with visible selection jumper secured During installation, a selection plug at the back of the behind strobe housing housing determines the desired strobe intensity. An • UL listed to Standard 1971 attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the • Regulated circuit design ensures consistent flash output side of the strobe lens. and provides controlled inrush current ' This product has been approved by the California State Fire Marshal (CSFM) pursuant to Audible notification appliance (horn): Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7125 - 0026:317 for allowable values and /or conditions concerning material presented in tnis • Low current. 24 VDC electronic horn with harmonically document. It is subject to re-examination, revision. and possible cancellation. This product was not approved by MEA (NYC) as of document revision dale. Refer to page 2 for listing rich output sound suitable for either coded or steady status of wire guards. Additional listings may be applicable; contact your local Simplex operation product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. • UL listed to Standard 464 " Simplex two-wire strobe synchronization operation is protected by U.S. patent No. 5.559,492 and SmarlSvnc hom /strode operation is protected under U.S. Patent No. 6.281.789. S4906- 0002 -2 9/2004 Strobe Application Selection Smart Sync Two -Wire Control Proper selection of visible notification is dependent on Smart Sync operation mode allows a two -wire circuit to occupancy, location, local codes, and proper applications provide the ability to activate both the horn and strobe on of: the National Fire Alarm Code (NFPA 72), ANSI the same NAC and then allow the horn to be silenced A117.1; the appropriate model building code: BOCA, while the strobe remains flashing. The horn operates as ICBO, or SBCC1; and the application guidelines of the "on- until - silenced" while the strobe operation is Americans with Disabilities Act (ADA). "on- until - reset." Synchronized Strobes SmartSync Control Sources Multiple Strobes. When multiple strobes and their • 4100U and 4010 Fire Alarm Control Panels (refer to reflections can be seen from one location, synchronized data sheet S4010 -0001 for details; refer to data sheet flashes reduce the probability of photo- sensitive reactions S4100-0031 for basic 4100U information) as well as the annoyance and possible distraction of • 4009 IDNet NAC Extender (refer to data sheet random flashing. The multi - candela strobes of these A/Vs S4009-0002) are synchronized by the controlling SmartSync operation • SmartSync Control Module (SCM) 4905 -9938 (refer to NAC. data sheet S4905 -0003) Additional SmartSync compatible notification appliances include separate horns and combination horn/strobe notification appliances. Product Selection Multi - Candela A/Vs Model Mounting Housing Color • "FIRE" Description -) 4906 -9127 Wall Red White 4906 -9129 White Red Horn with Multi- Candela Strobe; strobe intensity selectable as: 15, 30, 75, or 110 candela; operates with SmartSync two -wire 4906 -9128 Red White control Ceiling 4906 -9130 White Red Wall Mount AN Adapters Model Description Dimensions 4905-9937 Red Surface Mount Adapter Skirt; use to cover 1 -1/2" (38 mm) deep 5 3/8" H x 5 -1/4" W x 1 -5/8" D surface mounted boxes (136 mm x 133 mm x 41 mm) 4905 -9940 White depth with strobe = 4 -3/8" (111 mm) 4905 9931 Red Adapter Plate for mounting to Simplex 2975 -9145 box (typically for 8- 5/16" x 5 -3/4" x 0.060" Thick retrofit, may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975 -9145 Red Mounting Box, requires Adapter Plate 4905 -9931 7 -7/8" x 5 -1/8" x 2 -3/4" D (200 mm x 130 mm x 70 mm) SmartSync Control Module Model Description Dimensions 4905 9938 SmartSync Control Module with Class B or Class A output; mounts in 4" 4" x 4-1/8" x 1 -1/4" D (102 mm) square box; refer to data sheet S4905 -0003 for details (102 mm x 105 mm x 32 mm) Replacement Covers for Wall Mount ANs Model Description Dimensions 4905 -9994 Red cover with white "FIRE" lettering 5 -1/8" H x 5" W x 1 -1/2" D 4905 -9995 White cover with red "FIRE" lettering (130 mm x 127 mm x 38 mm) Wire Guards and Ceiling Mount AN Adapter Model Description -Dimensions 4905-9961' Wall mount red wire guard with mounting plate, compatible with semi -flush 6- 1/16" H x 6- 1/16" W x 3 -1/8" D or surface mounted boxes (154 mm x 154 mm x 79 mm) 4905 -9927' Red Wire Guard for mounting to flush mounted electrical box 8 -1/2" x 6 -1/8" x 3" (216 mm x 156 mm x 76 mm) 4905 -9928' Ceiling Red Adapter Plate, required to mount guard to surface 9" x 7" Mount mounted electrical box (229 mm x 178 mm) 4905 -9915 White Surface Mount Adapter Box Extension, use to cover 4 -3/4" x 6 -7/8" x 1 -1/2" deep, 4905 -9916 Red 1 -1/2" deep surface mounted boxes (121 mm x 175 mm x 38 mm) • UL listed by Space Age Electronics Inc. 2 S4906- 0002 -2 9/2004 • I " _ - AN S•ecifications Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range UL Listed Rating Regulated 24 VDC; see Note 1 below ULC Listed Rating 20 VDC to 30 VDC per ULC S526 -M878 Flash Rate and Synchronized NAC Loading 1 Hz; with up to 35 synchronized strobes maximum per NAC Environmental; Temperature and Humidity 32° to 122° F (0° to 50° C); 10% to 93 %, non - condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm to 3.31 mm ; two wires per terminal for in /out wiring Horn Output Characteristics 2400 to 3700 Hz sweep, modulated at 120 Hz rate Voltage 16 VDC 24 VDC 33 VDC Horn Output Ratings Sound Type (see Note 2) Steady Coded Steady Coded Steady Coded @ 10 ft (3 m) Reverberant Chamber, 86 dBA 82 dBA 88 dBA 84 dBA 90 dBA 86 dBA UL 464 Test Anechoic Chamber 92 dBA 91 dBA 94 dBA 95 dBA 96 dBA 96 dBA Housing Dimensions (with lens) 5 -1/8" H x 5" W x 2 -3/4" D (130 mm x 127 mm x 70 mm) Wall Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Mount Strobe Setting (see Note 3 below) 75 mA 116 mA 221 mA 285 mA Reference RMS Currents 18 VDC 70 mA 101 mA 184 mA 243 mA.. at other voltages 24 VDC 60 mA 84 mA 143 mA 185 mA Housing Dimensions (with lens) 4 -3/4 L" x 6 -7/8" W x 2 -5/8" D (121 mm x 175 mm x 67 mm) Ceiling Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Mount Strobe Setting (see Note 3 below) 86 mA 132 mA 250 mA 320 mA Reference RMS Currents 18 VDC 81 mA 119 mA 216 mA 283 mA at other voltages 24 VDC 70 mA 97 mA 167 mA 217 mA NOTES: 1. "Regulated 24 VDC" refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired, changes effective May 1, 2004. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the appliance. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. 2. Coded values are typical of the output measured with a Temporal coded or a March Time coded pulse and with a sound level meter reading on a "fast" setting. Under the same test conditions, coded horn output "peak" sound level readings are typically 4 dBA higher. 3. Currents are with horn on steady. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) Installation Reference, Surface or Semi -Flush Mounting o 6 - Mounting is compatible with 1 0 I IMPORTANT! WALL MOUNT single gang, double gang, and 4" (102 mm) square boxes, �� INSTALLATION HEIGHT REEMERGE 1 -1/2" (38 mm) deep, by others I07 _ r , II>•Ot�l_ U I Bottom of lens is either even IIMI with or slightly - Electrical Or`[[: ;•fit I ; O above bottom °.-- box outline Wiring access hole o'- Q ��� , of compatible I 1 ' ---- 4,"\ � boxes Wiring terminals for '�l � ! 'Jp p \ ` ! . I _ ......- 7 SmartSync operation ,I Illl` i I 1 • 11 Mounting Holes: =� g NFPA 72 requires 80" (2.03 m) 4" square that the entire lens minimum °""1e0�° 1111=r0 _ Single gang g (2) be not less than � L'� I Double gang (3) ��11I 80" and not greater I than 96" above the ° Transparent housing finished floor and lens assembly Intensity selection plug, accessible only rfrom rear of housing; • IL [1 n 1E factory setting is 15 cd Removable cover Strobe intensity (tool required) viewing slot 3 S4906- 0002 -2 9/2004 • •:'Ceiling Mount A/V�a Reference; • Ceiling reference, 4" (102 mm) square box, Optional 4905 -9928 Adapter Plate, surface mounted box 1 -1/2" (38 mm) minimum depth required for surface mounted electrical box Four mounting clamps included, two each side i 1 ll Ceiling reference, flush mounted box _ ! j l _ Optional 4905 -99151 -9916 Adapter, �, recommended for surface mounted box — — Wiring terminals are Opt R ed d W 4905-9927 i re Guard , All located behind the housing Red # ..— ' F 11 ....- ] End View 4— :1 I Strobe intensity viewing slot Intensity selection plug, • • accessible only from rear of lens housing; factory setting is 15 cd • Wall ,Mount Installation Reference;:.Adapter Plate ,'Guard, -and Adapter:Skirt- • Surface Mounting Reference 2975 - 9145 Box with Optional Adapter Skirt and Optional Wire Guard IIII 7 Surface mount conduit and O box shown for reference Ii711ICI= I =I =I: 4" box (10 pmm l m ) square (♦I =I. .�.... aur■ �, t�' _ I ( 38 m) deep ; 1. . El r ( Optional ___I�II1_ —� 1M o 0 4905 -9961 11111 —���� I Wire Guard I I AN `-LE IF0G°3G I = I L _ o R_ �- = i ' 4905 9931 Adapter Plate Optional Surface Mount Adapter Skirt, O 4905 -9961 Optional Wire Guard 1 -1/2" deep: 4905 -9937, Red; - (shown here for reference only, 4905 -9940, White (conduit knockouts 4905 -9931 Adapter Plate can be used on other mounting options) are provided on all four sides) Tvco. Simplex. the Simplex logo. IDNet. TrueAlert. and SmartSvnc are trademarks of Tyco International AG or its affiliates in the U.S. and /or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). S Simplex Tyco Safety Products Westminster • Westminster, MA • 01441 -0001 • USA S4906- 0002 -2 9/2004 m www .tycosafetyproducts- usa- wm.com c 2004 Tvco Way Products Westminster. All rights reserved. All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. . _ , . ;, 51 S TOPPE R ® Protective Cover To Help Stop Malicious and Accidental False Fire Alarms This unique and patented device has been helping stop -: -- - -,-_- - false fire alarms around the world for more than 20 years, , : ,- =-- ---' _-- without restricting legitimate alarms. It offers excellent F< ` ;,. IN CASE OF FIRE 9LIFIlicp protection against physical damage (both accidental and s PULL FIREOWARIA:- 'A.- intentional), dust and grime as well as severe ' S 4_:,; ,;'" • •,. I . en vironments inside and out It is ideal for schools, , .. colleges, hospitals, nursing homes, stores, hotels and �� public buildings of almost every kind where there is a ''. `. _ `-7—' 1 • threat of false fire alarms. ,, : _:!" a , How It Works .� j : y _.l ' ' „ tl CAS.E�10 ,1 Stopper II consists of a clear, tamperproof, super tough f+ . 'a k -. polycarbo shield and frame that fits over manual pull „ . , .! stations. When lifted to gain access to the actual alarm, it f,+ 77 s., sounds a piercing self- contained 95 dB or 105 dB warning -4 .--- - .: ;, horn (at one foot). Immediate attention is drawn to the `tJ °S area and a prankster will either run or be caught. The — ._` -.s: -- 0 cover is connected to the frame by a cable. When the - LEFT CEP';., ADA cover is lifted, it drops off of the frame and a horn will B S A sound (models with horn). Alarm will sound until the sn - „o° NEnna 3R cover is snapped back onto the frame or for the life of the ,¢nn"motlds Only, battery. • Proven effective for more than a decade in • Larger sizes and surface mounted pull stations helping stop false fire alarms without restricting accommodated with STI -3100 conduit spacer. legitimate alarms. • Polycarbonate tested to -40°F ( -40 °C) to 120T • Lifetime guarantee against breakage of (49 °C). polycarbonate housing in normal use (one year ° Weather resistant gaskets available. on electronic components). • When covering a pull station outside, UL requires N • Can be used as a guard against physical damage stations to be listed for outdoor use. P. to a manual pull station, with or without the Power source is 9 VDC alkaline battery on optional warning horn. standard Stopper II (remote powered unit is • Cover is UV- stabilized against sun deterioration. available). � • Optional horn has choice of 95 dB or 105 dB at • Not just for pull stations, this cover can also help one foot. protect other devices such as EPO's, call boxes, • Red units have "In Case of Fire...” label unless telephones and emergency shutdowns just by specified no label or custom label (charge for changing the color and messaging. custom label). • Fits virtually all manual pull stations indoors or out. • • Horn housing available in red, blue, green or • With backplate and gaskets, UL Listed to NEMA 3R yellow with custom labeling. Standards (IP 14 Rating). • UL /cUL Listed (also for custom labeling). 0 Safety Technology International, Inc. Safety Technology International (Europe) Ltd. i s 2306 Airport Road • Waterford, Michigan 48327 -1209 Unit 3 Olton Wharf • Richmond Road • Olton (arrit Phone: 248 - 673 -9898 • Fax: 248 - 673 -1246 Solihull • 892 7RN • England • Telephone: 44 (0) 121 707 2999 `. Toll Free: 800 888 45TI • E-Mail: info@sti-usa.com Facsimile: 44 (0) 121 707 8999 • E -mail: info @sti- europe.com - Web: www.sti-usa.com web: www.sti - europe.com 1 5T1. • 6 P4P,ER° II i Dimensions:and Technical _ Information Indoor Use: TESTING STI - 1100 With horn for flush mounting. It has been tested and approved or listed by: STI 110012C* With horn for flush mounted appliances includes relay contacts capable of operating from 9 -24 • Underwriter Laboratories S2466 VDC remote power or internal 9VDC battery • Factory Mutual No. 066A2.AY (STI -1100 only) power. • State of California (obtain local fire marshal approval) STI - 1130 With horn and conduit spacer for surface mounting. - • NEMA 3R and IP 14 Rating (only for Stopper II models STI 113ORC" Surface mounted version of the STk100RC - with backplate and gaskets) includes conduit spacer. STI Without horn for flush mounting. • New York City Board of Standards No. 947 -81-SA Co 5TI - 1230 Without horn, shipped with conduit spacer for • ADA Compliant (UL certified 52466) surface mounting. PATENTS rn Outdoor Use: All outdoor units include necessary gaskets. Rd 5TI - 1150 outdoor with horn for flush mounting. United States No. 4267549, Canada No. 11478282 < STI- 115ORC° With horn for flush mounted appliances includes relay contacts capable of operating from 9 -24 HORN HOUSING OJ VDC remote power or internal 9VDC battery power and includes weather gasket. COVERT 5.5 in.(140mm) O STI - 1155 Surface mounted version of the STI -1150. 3.2 in.(81mm) STI 115512C Surface mounted version of the STI- 115ORC 6.2 in.(158mm) !-' i includes conduit spacer. 511 -1250 Without horn for flush mount. SPACER \ Z in.(Slmm) STI - 3150 Without horn for surface mount exposed conduit ___t_. applications. 5TI - 3100 2"conduit spacer with 1/2" conduit entry (no SIDE VIEW gaskets included). MODELS WITH HORN. (STI -1100 Series) ST1 - 3104 2" conduit spacer with 3/4" conduit entry (includes 1 3/4" conduit entry gasket). STI - 1102 Replacement horn for cover with alarm. COVER / 6.5 in.(165mm) Custom - LBL Custom text message for horn housing. 3.2 in.(81mm) Sto per I I is intended to be used in areas where the incidence 7.0 in.(17emm) � of false f ire alarms from manual pull stations is high or has I proven to be a serious problem. Any disadvantage of this SPACER ,.. i device is more than balanced when one considers the 8s in.(216mm) 2 in.(Stmm) consequences of false fire alarms, especially if fire service personnel and equipment are responding to a false fire alarm SIDE VIEW when they are needed for a real fire somewhere else. Add to this the disruption to the facility when false alarms occur. If MODELS WITHOUT HORN (STI 1200 AND STI -3150 Series) you have, or may have, a problem with false fire alarms or physical /weather damage to your fire alarm activation devices, the Stopper II could prove invaluable. COVER /3 in.(76mm)'•• ., `WARNING: Q For RC models: UL Listing does not permit relay t contacts to connect to the fire alarm or a life safety function. The 3.2 in.(81mm) Power Supply for horns, according to UL Listing, cannot he connected �.: s in.(127mm) to a UL Listed Fire Alarm System. SPACER 5.5 in.(140mm) 2 in.(51mm) co 5T1.3003 r INSERT GASKET (1 /2 in. CONDUIT) ALL MODELS END VIEW I /571 -3004 GASKET (3/4 in. CONDUIT) ® `�� v A L (2) PROVIDED Q / STI -3100 CONDUIT SPACER • STANDARD SPACER ZI I, ‘9 .4116 4 0 INCLUDED WITH SURFACE MOUNT UNITS I riii: SUB -316 II 4.1 _ (.0407.-- 571.7280 BACKPLATE LOUVER -.1:.. • NOTE: 511 SUGGESTS USING THE 571.1280 BACKPLATE FOR WEATHER UNITS , `R WHEN MOUNTED ON AN UNEVEN SURFACE. F SUB-315 GRILL STI -3002 WEATHER GASKET FOR WEATHER OPTION (USE TWO WITH SPACER) 1 Pnnled In U.S.A. 511 -1100 Son. :. 1901. '92 '94. '93. '96, '9:. 2000. '02. '03 5U 11/03 • Simplex • System Accessories UL Listed* 4081 Series End -of -Line Resistor Harnesses Features For use as Class B end -of -line resistor: • • Connect these resistor harnesses where end -of -line resistors are required at remote locations to monitor wiring continuity • Refer to specific circuit specifications for end -of -line resistor requirements UL Listed to Standard 864 Product Selection - 9 -1/2" (241 mm) Model Reference Description"* 4081 -9001 733 -892 2.2 kf2, 1/2 W 4081 -9002 733 -893 3.3 kn., 1 W 4081 -9003 733 -896 4.7 kS2, 1/2 W 4081 -9004 733 -886 6.8 kf2, 1/2 W 4081 -9005 733 -984 1.8 kf2, 1/2 W 4081 -9006 733 -890 560 0, ), 1 W 4081 -9007 733 -891 1.2 kS2, 1 W —› 4081 -9008 733 -894 10 kf2, 1/2 W 4081 -9009 733 -912 20 S2, 1 W 4081 -9010 733 -973 1 kf2, 1 W 4081 -9011 733 -974 1 0 0 , 1 / 2 W 4081 -9012 733 -985 22 kfl, 1/2 W Typical 4081 Series Resistor Harness Assembly 4081 -9013 734 -086 4.99 kf2, 1/2 W, ± 1% (full size except for lead length) 4081 -9014 734 -092 2.4 kf2, 1/2 W 4081 -9015 734 -093 1.5 kit, 1/2 W 4081 -9016 734 -149 150 kf2, 1/2 W S •ecifications 4081 -9017 734 -171 3.9 kS , 1 W 4081 -9018 734 -168 10 kg), 1 W Overall Length Approximately 9 -1/2" (241 mm) • ± 5 %tolerance except as noted. Wire Length 7 (178 mm) ± 1" (25 mm) Wire Size 18 AWG (0.82 mm Insulation 600 V, black Leads Stripped 0.5" (13 mm); tinned Resistor Resistor leads are crimped to wires Attachment and covered with heat shrink tubing • This product was not approved by ULC, FM, MEA (NYC), or CSFM as of document revision date. Additional listings may be applicable. contact your local Simplex® product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. S4081 -0003 7/2004 • . • Tyco, Simplex. and the Simplex logo are trademarks of Tyco International Services AG or its affiliates in the U.S. and /or other countries. ®s • Tyco Safety Products Westminster • • Westminster, MA • • 01441 -0001 • • USA S4081 -0003 7/2004 ���� www .tycosafetyproducts- usa- wm.com �• 2004 Tyco Safety Products If'esttninster. All rights reserved All specifications and other information shmyn were current as of document revision date and are subject to change without notice.