Specifications 7 c 5f a 3 0 ne620 `0 CO 3 2—
• Single Duct - ControllerType oectE010 q„ „qs '`
SPV, SEV, SDV Series .P
r Single Duct Terminal Units . '
p e ' + rsrarmnave'' v 1
t
Product Overview
General Information Model SEV
Price has, as a primary component of its - „ ` t •
terminal unit line, the SPV (pneumatic ° - - I
controls), SDV (digital controls) SEV • q s 1 ;
(electronic controls) single duct VAV -_. .. ',, `',� _j c - • i •
assemblies. These units are designed to \ `"
control the airflow rate of conditioned air '
into an occupied space in response to a .
control signal, usually a thermostat. The
' . ,. ) '
clean and efficient design of these single I I ;,
duct terminal units result in a system
component which has minimal pressure • , a ::; ,
drop reducing fan horsepower require- \ .: "' `,:
ments, and low noise generation for quiet „ ,/' +t°
�, t (+
operation. A compact configuration makes / ” ' . : ".:;_, r .
this unit easier to use in today's crowded ���
mechanical spaces or in retrofitting " ' •
existing systems.
Control options for this product line are .
wide and varied with pneumatic, analog SXI/ X000
electronic and state of the art direct digital
control available to suit most any •
application. Most of the control options
utilize the exclusive Price SP -200 multipoint
sensor for accurate duct air velocity
pressure measurement. This allows the ControllerT a Controls
terminals to monitor the desired flow rate, Type
• dictated by the thermostat, and corn- P — Pneumatic 5 — Supplied by others
pensate instantly for any changes in supply E — Electronic (Digital Only)
air pressure that might tend to alter the D — Digital 6 — Pressure
supply volume. In other words, the net Dependent
result is a pressure independent variable 8 — Pressure Independent
air volume system. by Price .
In addition to the basic volume control
assembly, a complete line of accessories 4 Product Selection Checklist
is offered to meet specific job require-
ments. Sound attenuators, multi- outlet 11 Select Unit Inlet Size based on control and acoustic parameters.
adaptors and heating coils are all available. 21 Select Control type (Pneumatic, Electronic, Digital) based on system design.
These are factory assembled to the basic 3] Select Accessories ( Multi - Outlet Adaptor, Attenuator) as required.
assembly for shipment as an integrated 41 Select Reheat Coil, if required.
unit (see page F34). 5) Select Control Sequence based on system design.
i
Features:
• Capacities ranging from 50 - 8000 cfm in • A full 2” inlet connection to secure flex lubricating bearings.
11 sizes. and hard duct connections. • Discharge complete with slip and drive
• Full range of accessories available (i.e. cleat duct connections.
• Pressure independent operation. coils, attenuators, etc.) • • Can be used for VAV or constant volume • Special liners and insulations available
Protective metal shrouds for electronic see pages F59 - F63.
applications. and digital (by Price) controls. Protective
g y Certified in accordance with the ARI 880
• Available with pneumatic, electronic or metal cover optional for pneumatic certification program.
direct digital controls. controls.
to • Factory calibrated to job requirements. • Compact, lightweight design for ease of Product Information Index
z • Individually adjustable minimum and installation. Dimensional Data F31 -F32
3 maximum air volumes - easily field • 22 gauge zinc coated steel housing. Accessori Ps F33 F34
z ad • Control Options F9 -F27
1 /2" (13) thick, min. 1.5 lb density SP200 Sensor F35 -F37
• SP -200 multi -point flow sensor designed fiberglass internal insulation, coated to Air Volume Ranges F38
to maintain control accuracy indepen- prevent air erosion- meets requirements Selection Guide F39 -F41
dent of field installation conditions. for NFPA90A and UL181. Acoustical Data F42 -F46
• Gauge taps for flow measurement and • Damper blade constructed of two layers Coil Selection F47 -F58
< balancing. of heavy gauge galvanized steel with a Electric Coils F90 -F95
• Conveniently accessible externally sandwiched peripheral gasket of cross Liners - Cleanroom & Low
mounted controls. linked polyurethane foam to ensure tight Temperature Construction F59 -F63
• Inlet connection bead offers a means seal and no damper deflection. Low Leakage F -64
for secure flex duct connections. 30 I I r • Plated damper shaft is mounted in self- Suggested Specification F320 -F322
F_ All Mende dimensions 1 I ere soft conversion. m Copyright E.H. Price Limited 2004.
3 Imperial dimensions ate converted to metric and rounded to the nearest millimetre.
Ill Single Duct - Controller Type ,,,eFIED7OgF „,,re
pricE®
SPV, SEV, SDV Series 1 ,
U
Single Duct Terminal Units _
i
Dimensional Data
SPV Size 4 - • 1 /2” (13) thick, min. 1.5 lb density fiberglass
Removable Protective y g
Controller Cover internal insulation which meets require -
(optional) 4 "(121) ments of NFPA 90A and UL181.
'el---'Iss • 22 ga. zinc coated steel housing. Mechani-
Multi - Point Sensor cally sealed and gasketed, leak resistant
c/w Gauge Taps construction.
. 0o. U - • Rectangular discharge opening with slip
r � �1 T --- p and drive cleat duct connection.
,1_ Air Di =A 00 c
C - /, I pow - t/ee(31 � • Control assembly will be supplied as illus-
., �l L.__ - V '' c traced on right hand size unless specified
otherwise.
41R• 2° (51) j1 a • Gauge taps are standard.
(114) r L . • Pneumatic actuator supplied & mounted
B ' by Price.
• Clean, dry, 20 PSI (138 KPa) control air
required.
SEV Size 4 - 16
Multi -Point Sensor 18316° (487)►{ 1 /2" (13) thick, min. 1.5 lb density •
fi berglass internal insulation which meets
_ I t , requirements of NFPA 90A and UL181.
aG O i i ' p t • 22 ga. zinc coated steel housing. Mechani-
C -� �- Air _ Dia. =A i I ii 9 0 cally sealed and gasketed, leak resistant
I RoW 1 d ° (3) I 10011 (2411 construction. i II
i _ i �I t/—
• Rectangular discharge opening with slip
a 2" (511 — � �+ b - - - - -- and drive cleat duct connection.
B - 1 • Control assembly will be supplied as illus-
. L ' trated on right hand side unless specified
otherwise.
4 Removable Cover • Pressure independent.
SDV Size 4 - 16
1R• (13) Damper Shaft • 1 /2" (13) thick, min. 1.5 lb density fiberglass
internal insulation which meets require -
Multi Sensor ments of NFPA 90A and UL1B1.
c/w Gauge Taps • 22 ga. zinc coated steel housing. Mechani-
- Up cally sealed and gasketed, leak resistant
`� Die construction.
C ' Ate ► . iir )3) 00 0 • Rectangular discharge opening with slip
Row - and drive cleat duct connection.
L Ira! 2e 151)
I • Actuator & controls by others.
B — NI i I. ►f
•
•
•
• S.I. Units (mm) Imperial Units(inches)
Unit L/s CFM Outlet Inlet Length Outlet Inlet Length
Size Range Range B . C A L B C A L
4 0 -106 0 -225 305 at 102 562 12 8 4 22'/. w
5 0 -165 0 -350 305 203 127 562 12 8 5 22'/e Z
6 0 -212 0 -450 335 203 151 511 12 8 6 20' /a
7 0 -307 0 -650 16 254 178 511 12 10 7 20' /. Z
' 8 0 -378 0-800 335 254 203• 511 12 10 8 20' /e ac
9 0 -496 0 -1050 356 318 229 511 14 12'/: 9 20' /8
10 0 -637 0- 1350 356 318 254 511 14 12'/+ 10 20'/a
12 0-991 0-2100 as 381 305 511 16 15 12 20' /a
14 0 -1416 0 -3000 933 445 356 600 20 17'/: 14 23 b/a
16 0 - 1888 0 -4000 - 610 457 406 607 24 18 16 23 Vs
5) Copyright E.H. Price Limited 2004. 1 nii Metric dimensions 1 1 are soh conversion, 1
Imperial dimensions are converted to metric and rounded to Om nearest miliunetre. F 3 ■
• Single Duct — ControllerType „,P °• „ -9 price a
SPV, SEV, SDV Series t
Single Duct Terminal Units o r
A, Mr Np>no
Dimensional Data
SPV Size 24 x 16 • l /2” (131 thick, min. 1.5 lb density fiberglass internal
Optional .., • 11/ (38) insulation which meets requirements of NFPA 90A and
Multi -Point Sensor - \ Protective I U L 1 81 .
c/w Gauge Taps Controller Cover ^ / � — I i 43 ° ( 1 2 1 ) 22 ga. zinc coated steel housing. Mechanically sealed
tuts, and gasketed, leak resistant construction.
j1 • Rectangular discharge opening with slip and drive
ENE _ r Air 1
I cleat duct connection.
C Flow I . t ri • • Control assembly will be supplied as illustrated on
L - I right hand side unless specified otherwise.
L • Gauge taps are standard.
O 1 • Pneumatic actuator supplied & mounted by Price.
B , 4
(114) L • Clean, dry, 20 PSI (138 KPa) control air required.
SEV Size 24 x 16 • 1 /2" (13) thick, min. 1.5 lb density fiberglass internal
Multi -Point insulation which meets requirements of NFPA 90A and
' - 18 1 /2 ° (470) UL181.
Senso for line voltage 7
connection (see notes) 1 138) • 22 ga. zinc coated steel housing. Mechanically sealed
and gasketed, leak resistant construction.
• Rectangular discharge opening with slip and drive
_ 1.1.11A - 91/2. _ Air cleat duct connection.
( ) C Flow ` • Control assembly will be supplied as illustrated on
right hand side unless specified otherwise.
� �� ' �_ I •Line voltage must not exceed 277V AC.
4r— • Pressure independent.
D `Removable Cover L — •'�
e B 4 (121)
SDV Size 24 x 16 • 1 /2" (131 thick, min. 1.5 lb density fiberglass internal
Multi -Point Sensor 181 (470) insulation which meets requirements of NFPA 90A and
c/w Gauge Taps -1 x 4 3 /4 °1121) Ai 11/2"(38) UL181.
11-- I T U1 • 22 ga. zinc coated steel housing. Mechanically sealed
T "I and gasketed, leak resistant construction.
9'Jt Air • Rectangular discharge opening with slip and drive
C _ E cleat duct connection.
LI •I
M (1 1) Row I_ • Digital controls by control contractor.
• Gauge taps are standard.
0 B 1,1 3 /ts" 11141 • L
Optional Controls
Enclosure
. S.I.Unitslmm) Imperial Units(inches)
Unit L/e CFM Outlet Inlet Length Outlet Inlet Length
Size Range Range B C D E L B C D E L
24x 16 0 -3776 0 -8000 965 457 603 403 483 38 18 23'/e 15' /e 19
co w .
• w cc
r I'
�.�
-'-.. ;I!
_ -
f
F_32 I All Metric dimensions 1 I are soh convereion Copyright E.H Price Limited 2004.
3L Imperial dimension. are convened to metric and rounded ro Ilia ,.sst inrinmutre