Specifications Otis Elevator Company , 7216 SW Durham Road, Ste 900 Ci Otis Portland, OR 97224 Tel: (503) 639 -7045 Fax: (503) 684 -5427 A United Technologies Company www.otis.com 00V° March 26, 2012 Bob Hearing Bnk Construction, Inc. 45 82 Drive, Suite 53B Gladstone, OR 97027 Re: Consumer Cellular Portland, OR Otis #611079 Dear Bob, The elevator you have purchased for the Consumer Cellular project will be fully compliant with all required code authorities. In Oregon, the code authority for the elevator is the State of Oregon Elevator Division. The code enforced by the elevator code is ASME A17.1 -2007. The rule section you are interested in is rule 3.14 which points to rule 2.14 and the specific rule is 2.14.2.1. Attached is a copy of the rule since you are providing the flooring and it too, is required to be compliant with this section. Please feel free to contact Tom Faires at 503 - 572 -5911 if you have additional questions. Sincerely, OTIS ELEVATOR COMPANY O Ann Anderson Account Manager • ., ASME A17.1.2007 /CSA 844.07 projections from the car wall, excluding support rails, 2.14.2.1.6 Handrails, operating devices, ventilat- shall not be greater than 38 mm (1.5 in.). ing devices, signal fixtures, audio and visual communi- (e) Conveyor tracks shall be permitted in freight ele- cation devices, and their housings are not required to vators cars. conform to 2.14.2.1.1 through 2.14.2.1.4. (f) Heating equipment, ventilating fans, and air-con- 2.14.2.2 Openings Prohibited. Openings or hinged ditioning equipment, if used, shall be securely fastened or removable panels in an enclosure are prohibited, other in place and located above the car ceiling or outside the than as required for the following: enclosure. (a) signal, operating, and communication equipment 2.14.1.9.2 Passenger car floors shall have no pro- (b) entrances jections or depressions greater than 6 mm (0.25 in.). (c) vision panels 2.14.1.10 Side Emergency Exits. Side emergency (d) top emergency exit exits are prohibited. (e) ventilation 2.14.2 Passenger•Car Enclosures (f) access panels for cleaning of glass on observation (055) elevators (see 2.14.2.6) 2.14.2.1 Material for Car Enclosures, Enclosure Lin- (g) equipment access panels for maintenance and (055) ings, and Floor Coverings. All materials exposed to the inspection of equipment shall conform to the following car interior and the hoistway shall be metal, glass, or requirements (see also 2.7.5.1.4): shall conform to 2.14.2.1.1 through 2.14.2.1.6. (1) be of hinged type. (ED) 2.14.2.1.1 Materials in their end -use configura- (2) open only into the car. tion, other than those covered by 2.14.2.1.2 through (3) be provided with a lock so arranged that the 2.14.2.1.6 shall conform to the following requirements, door shall be openable from inside the car only by a based on the tests conducted in accordance with the specially shaped removable key. Locks shall be so requirements of ASTM E 84, ANSI /UL 723, NFPA 252, designed that they cannot be opened from the inside by or CAN/ULC-S102.2, whichever is applicable: the use of ordinary tools or instruments. Keys shall be (a) flame spread rating of 0 to 75 Group 1 Security (see 8.1). (b) smoke development of 0 to 450 (4) be provided with electric contacts that conform (01) 2.14.2.1.2 In jursidictions enforcing the NBCC, to 2.14.4.2.3(b) through (e) and 2.26.2.35, and are located where the building is designated by the building code as so as to be inaccessible from the inside of the car. When a high building, materials in their end -use configuration opened, the contact shall cause power to be removed shall have from the driving - machine motor and brake. (a) a flame spread rating for walls and ceiling of 0 to (5) be of the same material and construction as 25 with smoke development of 0 to 100 based on the required for the enclosure. test conducted in accordance with the requirements of 2.14.2.3 Ventilation CAN /ULC -S102 (b) a flame spread rating for floor surfaces of 0 to 300 2.14.2.3.1 Natural ventilation openings con - with smoke development of 0 to 300, based on the test forming to the following shall be provided in car enclo- conducted in accordance with the requirements of sures: CAN /ULC- 5102.2 (a) Openings exposed to the inside of the car shall (ED) 2.14.2.1.3 Napped, tufted, woven, Looped, and not be located in the portion of the enclosure walls similar materials in their end -use configuration on car extending from a point 300 mm (12 in.) above the floor enclosure walls shall conform to 8.3.7 or the NBCC and to a point 1825 mm (72 in.) above the floor. NFCC, whichever is applicable. The enclosure walls to (b) Openings less than 300 mm (12 in.) above the floor which this material is attached shall conform to shall reject a ball 25 mm (1 in.) in diameter and be 2.14.2.1.1. guarded to prevent straight - through passage. (c) Openings above the 1 825 mm (72 in.) level shall 2.14.2.1.4 Padded protective linings, for tempo- reject a ball 50 mm (2 in.) in diameter and be guarded rary use in passenger cars during the handling of freight, to prevent straight - through passage. shall be of materials conforming to either 2.14.2.1.1 or (d) Openings in the car ceiling shall be protected and 2.14.2.1.3, whichever is applicable. The protective lining shall conform to 2.14.1.6. shall clear the floor by not less than 100 mm (4 in.). (e) The total area of natural ventilation openings shall 2.14.2.1.5 Floor covering, underlayment, and its be not less than 3.5% of the inside car floor area divided adhesive shall have a critical radiant flux of not less than equally between the bottom and top of the car enclosure. 0.45 W /cm as measured by ASTM E 648 or conform (f) The total unrestricted opening in or around the to the requirements of the NBCC and ULC standard car doors or gates shall be permitted to be included as CAN /ULC- S102.2, whichever is applicable. part of the total natural ventilation required. 54 r 73u P2c f I- 00 2(07 ! s 605 SW 72,-,a( v -e- STRUCTURAL CALCULATIONS FOR CONSUMER CELLULAR INCORPORATED OREGON BUSINESS PARK III 15605 SW 72ND AVE. PORTLAND, OR 97224 -- TENANT IMPROVEMENT -- /3 9 oGINEE .. PROFF RF 444 12.1:7 j4/1/ F® c j u JP i OREGON p 8or 0 9 1 `'0 1 5 ' ''aC5 ) rQa tiN F. NOR EXPIRES: 12 / 31 / ' q, • Contents Plans P 1 - P3 Gravity Calculations G1 - G3 Contact Person: John E Nordling, PE Lateral Calculations L1 - L5 -- -- I NORDLING Proj. No.: 11 -242 NEW ELEVATOR STRUCTURAL 15605 SW 72ND 1 ENGINEERS, LLC PAC TRUST 6775 SW I I Ith. Suite 200 • Beaverton OR. 97008 Date: JAN 2012 By: JEN Sheet No.: COVER I I -- - - ------ --- - --- -- - --- = � — - -- —=rte— -— — — — -—— - - — —- 1. f I I 1 I 1 I 1 I I I 1 1 1 I 1 1 I 1 1 1 1 I III I I I I I I ,I 11 I I I 1 I I I I I I I I I I I I !II I I I 1 I I 11 11 1 1 I I I I I I I I I I I I I I 1 :1 I I 1 I I I II I 1 11 1 I 1 I I I I I I 1 I l 1 I I I I I P H I II H I I I I I I I I I I I 1 I I it I I I N II 1 Is I i 1 I 1 1 I I i I 1 1 I 11 I 1 I 1 1 ill 1 1 i II 1 1 0 I I I I I I I I I I I I I I 11 I 1 I 1 I 1 II It 1 I II I I I I I I I I I I I 1 I I I I 1 I nn tl 1 1 1 I I I I I I I I I I I I I I I _ I I I I I I �' I�. - T - - -�I I 1"" c D. I 1 I I I 1 I I I 1 I I I I I I I I I I I . I I rn I I I I I I I I I I I I I 1 1 1 I I I I I I I 1 1 I I I I I I I I 1 I 1 I I II f1 j � I I I I I I I I I I I I , I I I I I I ' ,1 1 ---r . I 1 I I I I I I I I I I 1 I I I 1 I I 1 I 1 1 1 1 I 1 I 1 1 1 1 I I I I I I I - i � 1 I III 1 I 1 11 1 1 I I 1 1 II I I I I I I I I I I I I I I I I I I L I I , I I I I I I I I I I I I I I i I — I :I I I \ 1 I I I I I I I I I I I I I I I I I I I I I I I I I 1 , 1 i I I I 1 I I 1 I I I I 1 I I I 1 1 I 1 I 1 1 1 1 I 11 I I I I I I I I I I I I I I I I I I 1 I I I 1 1 I - Ij I I I I I I I i I I I I 1 I I I I I I I I I I I I I I I I I I I I I I I 1 1 1 li I I I I I I I 1 I I I 1 I I I I I I I I I I I I I I I I 1 I I I I I 1 I I I I I I I I I I I I I I I I I I I I I I I I I 1 I I I I I I I I I 1 I I I Ill I I I I I I I I I I I I I 1 I I I I I I I I I I I 11 I I I I I I I I I I t I I I I I 1 I 1 I I I 1 I I I I I 1 I I I I I I 1 I I I I I I I I I I I I II 1 1 I I I I I I I I I I I I I I I I I I I I 1 1 1 I I I I I I I I l I I I I I I 11 I I I I I I I I 1 I I I I I I I I I I I 1 I I I I II I I 1 I I 1 I I I I 1 1 I I I I I I I 1 I I I 1 I I I I 1 I 1 I 1 I I I 1 I I I I I I I 1 I I I I I 1 Id I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 1 I I I I I I 1 1 1 II I I I I I I I 1 I I I I I I I I I I 1 I 1 I I I I I I I I I I I I I t I I I I I I I I I i I I I 11. I I I I I I I I I I I I I 1 I I I I I I I I I I I li. I I I I I —,— 11 I I 1 I I i I � 1 1 .. 1 1 • I , '"1 i I I i i 1 1 1 I Y II I • _ I — - --I NORDLING Proj. No.: 11 -242 ,,, STRUCTURAL NEW 605 SW 72 D ENGINEERS LLC PAC TRUST 0775 SW 1 1 1 t h , Suite 200 • Beaverton OR. 97008 Date: JAN 2012 By: JEN Sheet No.: P 1 • • -- I " --1 IT - i ''' T I B.7'...„ . 1 ...;... „,- 1 -- — , .. [1 • _1_ !--- 1 • If - — . - - 1 i ii i 1 ! ,[. 4:Lfl." 0 i ! 1 . 1 -ti.• • -I- . . . . . ' . . 11 . II 11 .. 1 1 LI li • - • I NORDLING Proj. No.: 11-242 STRUCTURAL NEW ELEVATOR 15605 SW 72ND . /----- ---. ENGINEERS, LLC .. PAC TRUST _— __— 6775 SW II 1 th, Suite 200 • Beaverton Olt, 97008 Date: JAN 2012 By: JEN Sheet No.: P2 r ._ _- _ -.,� :.m,m —;w ,.,:,..,... - - i.. --..^.:T.ii= _aR::m.. .Fc:. =__ T..T G,;--.. , ii � :14: 'li F ii i €, _ _... 1:1. ill II I 'q: . - -_ L _ _ i r - - ' � III , I ,I J IB CD ' 1 i 1 '1 ' .. I! I ,, I If .. '1 ' 4 ni f Ij - il ■ I .411 1 r - - - i -- , . I , , -- e i B3 ,', J II, iiii 'I 1t di, 4`` fF 1 'li ! .1'i i I� ,ICI • 1 J I i I j ,I , IV' I I I ,ill , 11 1 ,FII 11 Il , II I ,1 ,!ii r l !P 1 - - 1 J I 0 0 I_ I � J rl 1 I I NORDLING Proj. No.: 11 -242 NEW 605 ELEVATOR STRUCTURAL - ; ENGINEERS, LLC PAC TRUST 6775 SW 111th, Suite 200 • Beaverton OR, 97008 Date: JAN 2012 By: JEN Sheet No.: P3 Al ROOF RAFTER A2 ROOF RAFTER A3 LIFT BEAM . PSF PSF P5F P5F DL LL TW DL LL TW PLL 5,000 lbs . 15 25 4' -0" 15 25 • 4' -0" • • + P w . w 111111 111111 . 111111 • 111111 . A b d d b •b 19.6' 8.0' • I 1.6' (2) LVL1' /,x14 LVL1.9E (2) LVL1 /.x14 LVL1.9E W8x10 . R1 R2 R1 R2 R1 R2 RDL 588 588 RDL 240 240 RDL 38 38 LL 980 980 LL 400 400 LL 2500 2500 71, 1,568 1,568 n 640 640 2,538 2,538 • brg L 0.6" 0 6" brg L 0.24" 0.24" A36 V MAX 1,568 lbs - V MAX 640 Ibs M MAX 7,683 fl-lbs M MAX - 1,280 11-lbs V MAX 2,538 lbs M MAX 9,572 ft 1. V (d) 1,381 lbs I . I V (d) 453 lbs fv . 1.9 < 14.4 ksi N 42 < 328 psi fv.. 14 < 328 psi fb 14.7 < 23.8 ksi N 806 < 2,928 psi lb 134 < 2,928 psi ' Si ' Si • . 51 ADL 0.00 . A DL -0.13 A DL 0.00 A LL -0.22 ALL -0.01 A LL - 0.09 L/ +999 L/ +999 L/ +999 ok ok ok • A -0.35 A n -0.01 An =0.09 - L / +999 CR 1.00 CL 1.00 CR 1.00 CL 1.00 CD 1.15 Cf 0.98 CD 1.15 Cf 0.98 . I - ' • I NORDLING •.. Pro;. No.: 11 -242 STRUCTURAL 15 5 SW 72 DD • J J � . ENGI NEERS, LLC PAC TRUST I` 6775 SW Will. Suite 200 • Beaverton OR. 97008 Date: JAN 2012 By: JEN Sheet No.: G1 BI FLOOR BEAM 52 POST / FOOTING • PSF PSF P BI DL 3.330 lbs 1 LL 11100 Ibs DL LL T1.11 • 15 100 IS.9' (E) DL 118 lbs LL 3,830 Ibs Reduction = Dead 15 Live 100 Area 438 r 0.08 RLmtrr • 26.6 R 0.23 I.LR 76.9 Dead Load 4.05 k GL 5'v Live Load 20.93 k Total Load 24.98 k GL 64x21 Moment 000 k -ft GL 8'.x24 I IISS 3.5 x 3.5 x 0.25 0 I H (ft) K b x 3.50 10.0 10 W (.0 d y 3.50 10.0 1.0 111111 111111 111111 111111 A A A a I fa 8.6 < 16.1 ksi fb 0.0 < 30.4 ksi 1 23.5' 23.5' 1 3 1 ' Fy 46 ksi rx 1.32 E 29,000 ksi ry 1.32 Cc 112 ksi kVr x 90.9 A 291 in kVry 90.9 CL 6 x27 DF24F GL6 %x27 DF24F R1 R2 R1 R2 R3 R DL 3,331 3,331 R DL 3,277 4,236 0 FI'G: 4'-6" x 4'-6" x 12" LL 17,100 17,100 LL 16,821 21,744 0 W Idth 54 in As Reg I 166 n. 20,431 20,431 it 20,098 25,980 0 Depth 12 in brg L 4.66" 4 66" brg L 4.58" 5.92" 0.0" Bars (6) #4 1.176 so in V MAX 20,431 lbs V MAX 20,764 lbs Cover 2" d 9 75 in M MAX 120,032 ft-lbs M MAX 116,119 ft-lbs SBP 1.233 < 1.500 psf I V (d) 16,519 lbs I 1 V (d) 16,852 lbs Pc 3,000 Fy 60,000 ps i fv 136 < 240 psi fv 139 < 240 psi Vu - I 22.5 < 93.1 psi lb 1,756 < 2,400 psi 113 1,699 < 2,400 psi Vu - 75.0 < 186.2 psi Mu 20.289 < 50,241 11-lbs Si Si S2 A DL -0.10 A DL -0.09 0.04 A Li -0.50 ALL -0.48 0.19 L / 563 L/ 586 L / 189 ok ok ok A n. -0.60 A it -0.58 0.23 CR 1.00 Ci. 1.00 CR 1.00 CL 1.00 CD 1.00 Cv 0.84 CD 1.00 Cv 0.84 1 - NORDLING Proj. No.: 11 -242 STRUCTURAL NEW 15605 ELEVATOR SW 7 ND i k , ENGINEERS, LLC PAC TRUST 6775 SW 111th. Suite 200 • Beaverton OR. 97008 Date: JAN 2012 By: JEN Sheet No.: G2 53 POST / FOOTING 54 HEADER • P 51 DL 4,236 lbs P5F P5F I LL 21,144 Ibe DL LL TW 15 100 9.0' Dead Load 4.24 k Live Load 21.74 k Total Load 25 98 k Moment 000 k -ft 1 1SS 3.5 x 3.5 x 0.250 • H (ft) K b x 3.50 10.0 1.0 d y 3.50 10.0 1.0 W (VIII 111111 fa 8.9 < 16.1 ksi A A lb 0.0 < 30.4 ksi I I Fy 46 ksi rx 1.32 Il l 6 E 29,000 ksi ty 1.32 Cc 112 ksi kVr x 90.9 a (3) 2x10 DF -L No.2 A 2.91 in kl/ry 90.9 RI R2 R IX 405 405 FTC: 4'-6" x 4'-(" x 12" LL 2,700 2,700 Width 54 in As Reg n. 3,105 3,105 1.166 brg L I I" 1.1" Depth 12 in V MAX 3,105 lbs Bars (6) #4 1.176 sq in M MAX 4,658 ft Cover 2" d 9 75 in I V (d) 2,307 lbs I SBP 1,283 < 1.500 psf fv 83 < 180 psi fc 3,000 Fy 60,000 psi 871 < 990 psi tb Vu - I 23.4 < • 93.1 psi • Vu -2 780 < 1862 psi Si Mu 21,102 < 50.241 ft-lbs A DL -0.01 A LL -0.06 L/ +999 ok A n. -0.06 CR 1.00 CL 1.00 Co 1.00 Cf 1.10 -- - -- - - 1 NORDLING Proj. No.: 11 -242 NEW ELEVATOR 1 STRUCTURAL 15605 SW 72ND k ENGINEERS, LLC PAC TRUST J 6775 SW 111th. Suite 200 • Beaverton OR. 97008 Date: JAN 2012 By: JEN Sheet No.: G3 • • USGS Earthquake Hazards Program 2005 ASCE 7 Standard Lat: 45° 24' 25.39" N Ss and SI = Mapped Spectral Acceleration Values Long: 122° 44' 56.5" W 15605 SW 72nd Ave, Tigard, OR 97224 Ground Motion Ss 0.937 Si 0.336 • Occupancy Category II Intermediate Reinforced Masonry Shear Walls Site Class D R 3.5 .v 1, Importance Factor 1.00 Height of Structure 25.0 ft Structural Period T 0.224 Site Coefficients Ct 0.020 Fa 1.13 x 0.75 Fv 1.73 Cs SDS I / R 0.201 SMS Fa * Ss 1.054 CS MAX SDS I / T R 0.495 SM I Fv * S i 0.581 CS MIN 0.044 Sos I 0.031 SDS (2/3) SMs 0.703 IV Cs * W p 0.201 WP SDI (2/3) SMI 0.387 IASD =V* 0.7 0.141 Wp • Seismic Design Category SDC D S1 Wall 0.141 * 55 psf * 13' -6" * 2 / 2 = 104 plf Roof 0.141 * 12 psf * 10.8 ft = 18 plf = 123 pit' S2 Wall 0.141 * 55 psf * 13' -6" * 2 / 2 = 104 plf Roof 0.141 * 12 psf * 8.9 ft = 15 plf = 119 plf S3 Wall 0.141 * 55psf * 13' -6" * 2 / 1 = 209plf S4 Wall 0.141 * 55psf * 13' -6" * 2 / I = 209plf Ceiling 0.141 * 12 psf * 10.8 ft = 18 plf = 227 p1f W1 0.141 * 55 psf * 8.9 ft * 6.75 ft = 464 lbs W2 0.141 * 55 psf * 10.8 ft * 6.75 ft = 564 lbs W3 0.141 * 55 psf * 8.9 ft * 13.5 ft = 929 lbs W4 0.141 * 55psf * 10.8ft * 13.5ft = 1127 lbs NORDLING Pro;. No.: 11 -242 ni W ELEVATOR STRUCTURAL N E56 5 SW 72ND oraj J ENGINEERS, LLC PAC TRUST 6775 SW 111th. Suite 200 • Beaverton OR, 97008 Date: JAN 2012 By: JEN Sheet No.: L1 10.8' 52: 119 plr III 111111111 IIIIII I I 550 lbs II I + 564 lbs Q I I I I I,200 lbs • 650 lbs + 464 lbs I,200 lbs r 10.8' 1 ` 54: 221 elf' l I I IIIIIIIIIII IIIII I i - - ---1 iiiiaia - . 930 lbs —' .: P + 1 lbs 6 _ —' j £'s 2,100 lbs • 0 —� , N - — 1 j ' 1,225 lbs + 929 lbs 2,200 lbs . I - — I NORDLING Proj. No.: 11 -242 NEW ELEVATOR STRUCTURAL 15605 SW 72ND 1__ _ ° ENGINEERS, LLC PAC TRUST 6775 SW 111th. suite 200 13cavcrton OR. 37008 Date: JAN 2012 By: JEN Sheet No.: L2 10.8 10.13' r 1,200 lbs 1 1 00 I y 1,200 lbs II fQ 10 J n IIII fI tl - _ f TrTT 1 v tl tl - - ... . J. _ II LLLJ 1 =1 = —=7--1 t M , _ i ll _ 1 - _ .9 r . Seismic (lbs) 3,300 Pier 1 2,100 lbs ;�=-- -= .= ;� - -_:'� 2,100 lbs -- Height ft 135 __ r �_ _ �- Length ft 10.8' }�, - : - t _ Width in 8 Fixed ? FALSE - -t. -r- t i �1 Grout Spacing 32 I I I 1,__ Fs psi 24,000 `n _ I I to Es ksi 29.000 - - �... • t._ i_ -.: I'm psi 1,500 Ern -L psi 1,125,000 _ Ev psi 450,000 - - - — -- -) ; : ._� _ __ _ Wi est in 4.8 --- -- - - - -- _ = - .: . — — d m 116.6 i1 1i 1 1 1 11 11 1 1 1 L � � L , _ �� Height / Length 1.25 (H/L) 1.95 Rel Deflections 0.96 Rigidity (1 /Del) 1.04 Rigidity Summation 1.04 k % force to peir 1.00 k Summation 1.00 Veq k 3.30 M k -ft 44.55 M /Vd 1.39 fv = 1.5V /b *jd psi 8.84 Fv w/o reinf psi 35.00 Fv w/ reinf psi 58.09 . Bar Spacing in o/c 48 Av Rcq'd in not req'd Bar# 2 #4 Bar Area in 0.392 , check ok I NORDLING Proj. No.: 11 -242 . n NEW ELEVATOR STRUCTURAL 15605 SW 72ND ENGINEERS, LLC PAC TRUST 6775 SW 111th. Suite 200 • Beaverton OR. 97008 Date: JAN 2012 By: JEN Sheet No.: L3 10.8' 1,200 lbs I i 1 ei r -.1 Seismic (lbs) 3,400 Pier 1 Pier 2 2,200 lbs I Height ft 13.5' 13.5' R R _ f Length ft 2.8' 7.9' 11-1 _ r _ -Tri Width in 8 8 Fixed ? FALSE FALSE ri - Tri-ii Grout Spacing 32 32 FF Fs psi 24,000 24.000 /t FH F• -1 _� Es ksi 29.000 29,000 I I fm psi 1,500 1,500 Psi Li �I-- 1 ---4� Em psi 1,125,000 1,125,000 450,000 450,000 - in 4.8 4.8 _ : I- I est _ = i - I:I - -,I - - �- - - -* d in 30.2 85.3 i i � -- 1 1 1 Height / Length 4.82 1.71 J (H/L) 112.08 4.99 2'8 ... . 1 ' g . Rel Deflections 38.53 2.09 Rigidity (1 /Def) 0.03 0.48 Rigidity Summation 0.50 k % force to peir 0.05 0.95 k Summation 1.00 Veq k 0.17 3.23 M k -ft 2.36 43.54 M /Vd 5.36 1.90 fv =1 5V /b *jd psi 1.81 11.81 Fv w/o reinf psi 35.00 35.00 Fv w/ reinf psi 58.09 58.09 Bar Spacing in o/c 48 48 Av Req'd in not req'd not req'd Bar# 2 #4 2 #4 Bar Area : in 0.392 0.392 check ok ok NORDLING Proj. No.: 11 -242 - 1115 STRUCTURAL NEW ELEVATOR 15605 SW 72ND i ENGINEERS, LLC PAC TRUST 6775 SW 111th. Suite 200 - Beaverton M. 97008 Date: JAN 2012 By: JEN Sheet No.: L4 i 10.8' v 1 1,200 i j 1 4-4---E-:11 I rti 11 t-1 Seismic (Ibs) 3,400 Pier 1 Pier 2 Height ft 13.5' 13.5' 2,200 Ibs 'IL- t - - - - -- Length ft 2.8' 2.8' ll . _ - - _ = -= Width in 8 8 T 11 - f - -- j 1 II I( II II - Fixed ? FALSE FALSE Grout Spacing 32 32 II li II II tr II Ii II II II II Fs psi 2 4,000 24,000 II II II II --} ! : jj i.„!.1 f ks i 2 1,50 0 29,00(► `� fm psi 1,500 1.500 II II II II II .I IL f Em psi 1,125,000 I,I25,000 ��11 Ev psi 450,000 450,000 I j est in 4.8 4.8 • _ LII� - LI 1 i 1, 11. d in 30.2 30.2 I - - - i r i Height / Length 4.82 4.82 L _I I (H/L) 112.08 112.08 1 2.8' ^ . 2.8' , Rel Deflections 38.53 38.53 Rigidity (I /Det) 0.03 0.03 Rigidity Summation 0.05 k % force to peir 0.50 0.50 k Summation 1.00 Veq k I.7Q 1.70 M k -ft 22.95 22.95 M /Vd 5.36 5.36 fv = 1.5V /b *jd psi 17.57 17.57 Fv w/o reinf psi 35.00 35.00 Fv w/ reinf psi 58.09 58.09 Bar Spacing in o/c 48 48 Av Req'd in not req'd not req'd Bart/ 2 #4 2 #4 Bar Area in 0.392 0.392 check ok ok NORDLING Proj. No.: 11 -242 S TRU CTU RAL NEW 605 ELEVATOR _ _ ENGINEERS, LLC PAC TRUST J 6775 SW 111th. Suite 200 • Beaverton OR. 97008 Date: JAN 2012 By: JEN Sheet No.: L5