Loading...
Plans I O 2z0 5■ GV,b 305 FP . P-© l0 - a 4 COOPER Notification Series RSS and RSSP Strobes and Strobe Plates RECVED APR 0 6 2010 ,' - CITY OF TIGARD F p Wall - -- _ BUILDING DIVISION f FAR , ; ►,_. s Series RSS Series RSS Series RSSWP RSS Round Description Features • The Wheelock patented Series RSS Strobe Appliances and Approvals include: UL Standard 1971, New York City (MEA), Series RSSP Strobe Plates have lower current draw while California State Fire Marshal (CSFM), Factory Mutual (FM 1. and maintaining outstanding performance, reliability and cost Chicago (BFP) See approvals by model in Specifications and effectiveness. These versatile appliances will satisfy virtually all Ordering Information requirements for indoor, wall or ceiling mount applications. • ADA /NFPA /UFC /ANSI compliant. Meets OSHA 29 Part Strobe options for wall mount models include 1575 or the 1910.165 Wheelock Patented MCW multi - candela strobe with field • Wall mount Multi- Candela models are available with Field selectable candela settings of 15/30/75/110cd or the high Selectable Candela Settings of 15/30/ 75/110cd or 135/185cd. intensity MCWH strobe with field selectable 135/185cd. Single Candela models are available in 1575cd Ceiling mount models include the patented MCC multi - candela Ceiling mount Multi- Candela models are • ceiling strobe with field selectable intensities of 15/30/75/95cd or the high intensity MCCH strobe with field selectable available with field selectable candela settings of 15/30/75t95cd 115/177cd. or 115/177cd. (Round or Square) All models may be synchronized using the Wheelock SM, • Strobes produce 1 flash per second over the regulated voltage DSM Sync Modules, Wheelock Power Supplies or other range manufacturers panels incorporating the Wheelock Patented 12 and 24 VDC models with wide UL "Regulated Voltage" us- Sync Protocol. Synchronized strobes can eliminate possible ing filtered (DC) or unfiltered VRMS input voltage restrictions on the number of strobes in the field of view. Wheelock's synchronized strobes offer an easy way to comply • Synchronize using the Wheelock sync modules or panels with with ADA recommendations concerning photosensitive epilepsy built -in Wheelock Patented Sync Protocol as well as meeting the requirements of NFPA 72. • Fast installation with IN /OUT screw terminals using #12 to #18 The Wheelock Series RSS Strobes employ a Patented Integral AWG wire Strobe Mounting Plate that can be mounted to a single gang, double gang, 4" square, 100mm European backboxes or the SHBB surface backbox. If the flush backbox has side or top space between it and the finished wall, the NATP (Notification For Weatherproof Series RSS See Datatsheet S9004 Appliance Trimplate) may be used. It provides an additional .65" of trim for the Appliance. An attractive cover plate is provided for a clean, finished appearance on all models. The Series RSSP Multi - Candela Strobe Plates are a cost effective way to retrofit required wall strobe appliances to bells, horns, chimes, multitones or speakers and easily mounts to standard 4" backboxes or for surface mount use with the Wheelock SBL2 surface backbox. ® ;: ;. - MEA APPROVED S5391 151 -92 -E 7125-0785:141 7300 - 0785:154 NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND /OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND /OR OTHERS. General Notes: ' • Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range ". Note that NFPA -72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. • Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32 °F to 120 °F (0 °C to 49 °C) and maximum humidity of 93% (± 2 %). • Series NH horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). • "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range ". Table 1: Average RMS Current* RSS /RSSP - Wall Mount Ceiling Mount RSS /RSSP 241575W 24MCW 24MCWH 24MCC 24MCCH 24VDC Models 1575cd 15cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd 75cd 95cd 115cd 177cd UL max° 0.090 0.060 0.092 0.165 0.220 0.300 0.420 0.065 0.105 0.189 0.249 0.300 0.420 RSS/RSSP RSS /RSSP DC Wall Mount 24V Models * RMS current ratings are per UL average RMS method. UL max current 121575W rating is the maximum RMS current within the listed voltage range (16 -33v for 24v units). For strobes the UL max current is usually at the minimum 12 vdc 0.152 listed voltage (16v for 24v units). For audibles the max current is usually at UL max* 0.255 the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. Table 2: Audibles /Speakers for RSSP Strobe Plate P roduct Series Multitone Appliances AMT, MT Wiring Diagrams # SERIES RSS /RSSP APPLIANCE Horns AH, NH, HS Motor Bells MB- G6 /G10 FROM + + TO NEXT PRECEDING - APPLIANCE Speakers ET- 1010/1080, E70, ET70 APPLIANCE, SYNC OR EOLR MODULE, POWER A Chimes CH70 SUPPLY OR FACP • SERIES RSS /RSSP APPLIANCES SYNCHRONIZED SERIES RSS /RSSP APPLIANCES SYNCHRONIZED WITH DSM MODULE SINGLE CLASS "A" NAC CIRCUIT WITH MULTIPLE DSM MODULES DSM DSM #1 STROBE - Strobe NAC C Sync NAC SYNC u. • + CIRCUIT r O� O � +OUTS WNW. L r - 0, IN A I DSM#2 i � MMINUS 1 , 0 Strobe NAC Gr.' Sync O + AUDIBLE /1 • + MINUS IV I DSM #3 + IN 2 I E� Sync MIE® P S TROBE +oUT 2 Strobe NAC Cir. ralreff CIRCUIT RETURN DSM Interconnecting wiring shown. Maximum of twenty (20) STROBE /PLATE ASSEMBLY AUDIBLE & VISIBLE APPLIANCE OPERATE IN UNISON SERIES RSS /RSSP APPLIANCE SYNCHRONIZED WITH SM MODULE SINGLE CLASS "B" NAC CIRCUIT TO NEXT S M FROM APPLIANCE PRECEDING - - OR EOLR F + STROBE APPLIANCE, SYNC Ir I ' n Strobe STROBE fri MODULE. POWER NAC SUPPLY OR FACP 0 A Circuit ate CO STROBE AUDIBLE +Audible P EOLR Audible STROBE /PLATE ASSEMBLY SERIES RSS /RSSP APPLIANCES SYNCHRONIZED AUDIBLE & VISIBLE APPLIANCE OPERATE INDEPENDENTLY WITH PS - 12/24 - 8CP or PS - 12/24 - 8MP FROM + + TO REM Series PS- 12124 -AMP PRECEDING APPLIANCE APPLANCE OR _ OR COLS FACP AS < fa OUTPUTS 1_ ' 14 + TO 4 - CLASS � 1 11 PRECEDING STROBE OR w �� STROBE. SYNC - - — 1 f - — — — — - EOL A OR MODULE. POWER I f AS SUPPLY OR FACP 2 - CLASS iii. ,, ,, C A .. m P STROBE APPLIANCE —1 AS < " For detail using SM or DSM Sync Module refer to Data Series PS- 12124 -BMP Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring information on the power supplies refer PS- 24 -8MC. Specifications and Ordering Information Order Wall Ceiling Non- Strobe 24 12 Color Color Square Agency Approvals Model Mounting Options"' or Code Mount Mount Sync Candela VDC VDC RED WHITE UL MEA CSFM FM BFP Round RSS - 24MCW -FR 940 X - X 15/30/75/110 X - X - B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS- 24MCW -RN 9401 X - X 15/30/75/110 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS- 241575W -FR 7471 X - X 15 (75 on Axis) X - X - B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS- 241575W -FW 7788 X - X 15 (75 on Axis) X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS- 121575W -FR 7476 X - X 15 (75 on Axis) - X X - B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS- 121575W -FW 7468 X - X 15 (75 on Axis) - X - X B,D,E,F,G,H,J,N,O,R,X Square X X X X X RSS - 24MCC -FW 3158 - X X 15/30/75/95 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X • RSS - 24MCC -FR 3157 - X X 15/30/75/95 X - X - B,D,E,F,G,H,J,N,O,R,X Square X X X X • RSS- 24MCCR -FW 3160 - X X 15/30/75/95 X - - X B,D,E,F,G,H,J,N,O,R,X Round X X X X ' RSS- 24MCCH -FW 3461 - X X 115/177 X - - X B,D,E,F,G,H,J,N,O,R,X Square X X X X • RSS- 24MCCHR -FW 3463 - X X 115/177 X - - X B,D,E,F,G,H,J,N,O,R,X Round X X X X • RSS - 24MCWH -FR 3465 X X 135/185 X X B,D,E,F,G,H,J,N,O,R,X Square X X X X • RSS - 24MCWH -FW 3464 X X 135/185 X X B,D,E,F,G,H,J,N,O,R,X Square X X X X • RSSWP- 2475W -FR** 9013 X - X 180@ 77 °F X X X - B,D,E,F,G,H,J,N,O,R,X Square X X X X • 75@ -31°F RSSWP- 2475W -F" 3034 X - X 180@ 77 °F W X X - X B,D,E,F,G,H,J,N,O,R,X Square X X X X • 75@ -31°F RSSP- 121575W -FR 7798 X - X 15 (75 on Axis) - X X - D,E,Z Square X X X X X RSSP - 24MCW -FR 9402 X - X 15/30/75/110 X - X - D,E,Z Square X X X X X RSSP- 241575W -FR 7793 X - X 15 (75 on Axis) - - X - D,E,Z Square X X X X X *PENDING All models sync with Wheelock SM. DSM or PS- 12/24 -8CP or PS- 12/24 -8MP. # Models are available in either Red or White. Call Customer Service for Order Code & Delivery. **For Weatherproof Series RSS Strobe specifications see data sheet S9004. ***Refer to data sheet S7000 for mounting options. Architects and Engineers Specifications The visual notification appliances shall be Wheelock Series RSS Strobe Appliances or approved equals. The Series RSS shall meet and be listed for UL Standard 1971 (Emergency Devices for the Hearing- Impaired) for Indoor Fire Protection Service. The strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. The strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). When • Strobe Plates are to be installed, they shall be the Wheelock Series RSSP Strobe Plate and shall have the same electronic circuitry as the Wheelock Series RSS. The Series RSS Strobe shall be of low current design. Where Multi - Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15130/75/110cd or 135/185cd for wall mount and 15/30/75/95cd or 115/177cd for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built -in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non - synchronized flash rate. The strobes shall be designed for indoor surface of flush mounting. The Series RSS Strobe Appliances shall incorporate a Patented, Integral Strobe Mounting Plate that shall allow mounting to single - gang, double -gang, 4 -inch square, 100mm European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. An attaching cover plate shall be provided to give the Appliance and attractive appearance. The Appliance shall not have any mounting holes or screw heads visible when the installation is completed. The Series RSSP Multi - Candela or single candela Strobe Plate shall mount to either a standard 4 inch square backbox for flush mounting, or the Wheelock SBL2 backbox for surface mounting. All notification appliances shall be backward compatible. NOTE. Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock, Inc. standard terms and conditions. Mt WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Made in USA SO410 RSS /RSSP 02/08 NJ Location FL Location VA Location 273 Branchport Ave. 7565 Commerce Ct. P: 877 - 459 -7726 Long Branch, NJ 07740 Sarasota, FL 34243 F: 703 - 294 -6560 P: 800-631-2148 P: 941-487-2300 F: 732-222-8707 F: 941-487-2389 www.coopernotification.com Cooper Notification is Wheelock" (MEDJ SAFEPATH' WAVES, arl COOPER Notification Fes o - ct 2 FIRE SYSTEM ACCESSORY Model 5495 Distributed Power Module +At In an emergency, you need maximum power. RFCFJ\!FD sA APR 0 6 2010 The 5495 Distributed Power Module by Silent Knight is the most powerful and cost- effective power supply available today. It delivers 6 amps of notification ' appliance circuit power and built -in synchronization for appliances from System Sensor,Gentex®, AMSECOO, Wheelock and Faraday — what you need to drive power -hungry components like ADA notification appliances. The 5495's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. And, ADA retrofits are easier and less expensive with the 5495 because it integrates into current systems without the costly investment in new components. For the most sophisticated and cost - effective notification power supply available, you need the 5495. Call Silent Knight today for more information at 1- 800 - 446 -6444. Model 5495 • Independent trouble relay Distributed Power Module • AC loss delay option shuts off power The 5495 is a 6 amp notification power to non - essential high- current expander that provides its own AC accessories like magnetic door power connection, battery charging holders circuit, and backup battery for use with • Built -in synchronization for fire and security controls such as the appliances from System Silent Knight Model 5208 Fire Control Sensor®,Gentex®, AMSECO®, /Communicator. The 5495 is the cost- Wheelock and Faraday effective solution for powering Cs, • notification appliances required by the Stand alone operation Americans with Disabilities Act (ADA). • Lightweight design adds to ease of The 5495 has built -in ANSI cadence installation and reduces shipping pattern, which can upgrade older costs control panels that lack cadence • Operates with most polarized, UL capability. Listed notification devices Features • UL 864 & 1481 listed Nis • UL Listed for 6 amps of notification • CSFM approved - power Model 5495 • ANSI Cadence pattern output • Power supply's advanced switch capability built -in Distributed Power Module mode design reduces damaging heat and manages power up to 50% Connection to Local Fire Control more efficiently than other systems The 5495 may be connected to a local 4.7kS2 end -of -line resistors provided. • Dip switches allow for easy fire control which utilizes Class A or Since the 5495 draws very little power reconfiguration Class B type notification circuits from the control, it is possible to operating between 9 and 32 VDC. The • 24 VDC filtered output voltage p g connect one 5495 to each notification on the control panel and still • Four power - limited notification control panel's notification circuit is p connected to one of the inputs on the provide full supervision of the outputs; 2 Class A or 4 Class B, or 1 notification circuits all the wa back to Class A and 2 Class B 5495. The control panel's notification Y circuit end -of -line resistor is also the control panel. • Additional continuous auxiliary connected across two terminals on the output 5495, which provides supervision SILENT • 3 amps per output circuit between the 5495 and the fire control • 2 inputs; 2 Class B or 2 Class A panel. Polarized audible and/or visual ` KNIGHT • Ground fault detector /indicator notification devices are then connected to the 5495 signal circuits using the by Honeywell - FjRE SYSTEM ACCESSORY Model 5495 2 Distributed Power Module Supervision Current: Input The 5495 supervises a variety of Standby 75 mA voltage range: 9 - 32 VDC functions including: Alarm 175 mA Battery charging • Low AC power Auxiliary capacity: 33.0 AH • Low battery condition power circuit: 1 Ambient temp.: 32° to 120° F • Earth ground fault Notification 0° to 49° C • Auxiliary output power limit circuits: 4 Mechanical condition Output Dimensions: 12.25" W x 16" H x • EOL supervision trouble or configuration: 2 Class A (Style Z) 3" D (30.88 cm W power limited condition at an 4 Class B (Style Y) x 40.64 cm H x output (1 Class A & 7.62 D cm) When a trouble condition occurs, 2 Class B) Indicator Lights the 5495 creates a trouble condition on the host control signal Amps per AC power on : Green circuits to which it is connected. the output circuit: 3.0 (6.0 amps total) Battery trouble: Yellow 5495 still maintains the ability to be Notification Ground fault: Yellow activated by the host control. In circuit output: 20.4 to 27.3 VDC Aux trouble: Yellow addition, the 5495 provides a Form @ 3.0 amps each, C trouble relay output as an 4.7 ki2 EOL Output alternative to using the notification resistor required troubles (1 -4): Yellow circuit trouble. on each Class B Approvals: circuit UL: 864 & 1481 Electrical Specification No. of inputs 2 NFPA: 72 AC input: 120 VAC at 2 amps Output: 24 VDC at 6 amps Input CSFM configuration: 2 Class B or 2 Class A Model 5495 Block Diagram Signal Circuit Output Signal 1 Signal 1 Input Distributed Signal 2 Signal Circuit Output Signal 2 Power input Module 5495 Signal 3 (Optional) Signal 4 120 VAC Aux. Power Trouble Output Local Fire Control (Alternative to notification circuit trouble.) SILENT This document is not intended to be used for installation purposes. We try to MADE I N AMERICA - fikt KNIGHT keep our product information up -to -date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350395 Rev B, 12/05 subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, Mn 553694927. Copyright © 2005 Silent Knight Phone: (800) 328 -0103, Fax: (763) 493 -6475. F P5 gd 10 -0oc .9 ci - Global Project Values: 111= llr SILENT Project Name: Comsys Standby Hours:I 24 I TO KNIGHT Project ID: Alarm Mins: 5 I Prepared By: Adam Sweet Derating Factor:1 1.2 I 5495 Power Expander Calculations Date: 2/2/2009 I Voltage Drop Warning Threshold % :I 10 Panel ID: 15495(1) I Model: Silent Knight 5495 Power Expander Max Circuit Current: 3 Amps Location: 13rd Floor Tele /Elec Room I Volts: 24 VDC Max Panel Current: 6 Amps mt Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ o /o Ckt.# Circuit Name Drop Standby Alarm & Type 1000 Ft. One -Way Ohms EOL 1 3.1.1 0.000 0.489 #14 Solid 2.52 145 0.73 20.04 1.75% 2 3.1.2 0.000 0.941 #14 Solid 2.52 280 1.41 19.07 6.51% 3 3.1.3 0.000 1.020 #14 Solid 2.52 180 0.91 19.47 4.54% 4 Spare 0.000 0.000 #14 Solid 2.52 0.00 20.40 0.00% Aux 5495(1) Aux Power Out 0.000 0 000 #12 Solid 1.59 0.00 20.40 0.00% 5495 5495 Power Expander 0.075 0.205 2.450 (Amps) Total Output Power Required Total Standby Current (Amps) 0.075 2.655 Total Alarm Current (Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes / 60 (5 Mins) . ' 171 Total Standby AH Required 1.800 0.221 Total Alarm AH Required APR 0 6 2010 Total Combined AH Required 2.02 Wire resistances are based upon an ambient temperature of 72 degrees F. Because of Multiply By The Derating Factor 1.20 the minimal difference between solid and stranded wire no differentiall® Minimum Battery AmpHours Required 2.43 bUjLUI1�(i D IVISION Panel ID: 5495(2) Model: Silent Knight 5495 Power Expander Max Circuit Current: 3 Amps • Location: I Volts: 24 VDC Max Panel Current: 6 Amps Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Drcp Ckt.# Circuit Name Standby Alarm & Type 1000 Ft. One Way Ohms EOL 1 5495(2) Circuit 1 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% 2 5495(2) Circuit 2 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% 3 5495(2) Circuit 3 0.000 0.000 #14 Solid 1.59 0.00 20.40 0.00`% 4 5495(2) Circuit 4 0.000 0.000 #14 Solid 1.59 0.00 20.40 0.00% Aux 5495(2) Aux Power Out 0 000 0.000 #12 Solid 1.59 0.00 20.40 0.00% 5495 5495 Power Expander 0.075 0.205 0.000 (Amps) Total Output Power Required Total Standby Current (Amps) 0.075 0.205 Total Alarm Current (Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes / 60 (5 Mins) Total Standby AH Required 1.800 _ 0.017 Total Alarm AH Required Total Combined AH Required 1.82 Wire resistances are based upon an ambient temperature of 72 degrees F. Because of Multiply By The Derating Factor 1.20 the minimal difference between solid and stranded wire no differential was made. Minimum Battery AmpHours Required 2.18 LI SILENT KNIGHT Circuit Configuration Project Information Project Name: Comsys Project ID: 0 Prepared By: Adam Sweet Date: 2/2/2009 Ckt. Number: 1 Panel ID: 5495(1) Ckt. Name: 3.1.1 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 2 NS- 24MCC -FW 15CD 0.000 0.082 0,000 0.164 5 RSS - 24MCCR -FW 15CD 0.000 0.065 0.000 0.325 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.489 Ckt. Number: 2 Panel ID: 5495(1) Ckt. Name: 3.1.2 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 6 NS- 24MCC -FW 15CD 0.000 0.082 0.000 0.492 5 RSS - 24MCCR -FW 15CD 0.000 0.065 0.000 0.325 1 NS- 24MCC -FW 30CD 0.000 0.124 0.000 0.124 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.941 Ckt. Number 3 Panel ID: 5495(1) Ckt. Name: 3.1.3 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 3 NS- 24MCC -FW 95CD 0.000 0.275 0.000 0.825 3 RSS - 24MCCR -FW 15CD 0.000 0.065 0.000 0.195 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 1.020 Ckt. Number: 4 Panel ID: 5495(1) Ckt. Name: Spare Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 0.000 [Page Too Large for OCR Processing] [Page Too Large for OCR Processing]