Loading...
Specifications RDI RECEIVED FEB 1 2012 CITY OF Multi - Circuit Condensers BUILDING D TIGARD IVISION with CVD Technology ® _T. _ Now approved for use with Manitowoc QuietQube® Ice Machines OF G Approved.. .. 1...... • Conditionally Approved.....„....... [ ] See Letter to: Follow.................. [ ] Attached . sy��� _ Permit 2 ;:ttli-la■ • • �� • • t '_77127 L By: .eZa Date: -rL ■ F Approved plans shall be on job site. . OFFICE COPY anitowoc CONTENTS Multi -Pak Advantages 3 Multi -Pak Refrigeration Systems 4 Dimensional Data 5 Job Information Request Form 6 Warranty 7 2 V ULTI - PAK • V ulti- circuit Condens Unit I he all new Multi -Pak is a multi- circuited vertical discharge condensing unit that can be configured to handle multiple compressors. The MC1 single fan model is capable of handling up to three compressors with a maximum of 5 HP. The MC2 two fan model is capable of handling up to five compressors with a maximum of 8 HP The MC3 three fan model is capable of handling up to seven compressors with a maximum of 14 HP. The MC4 four fan model is capable of handling nine compressors with a maximum of 20 HP. Multi -Pak Advantages: • Head master valves (allows refrigerant to bypass he • Available with Hermetic, Semi - hermetic or S condenser coil during cold weather conditions by troll compressors maintaining a minimum head pressure) • Installer has only one unit to mount (reduces the • Color -coded wiring amount of space required) • All units have liquid line sight glass and dryer • Single point electrical connection • Single energy efficient 1/2 HP (1100 RPM) • Condenser circuits may be allocated for use with PSC fan motor ice machines or other condenser requirements • Large 24" diameter fan blade • Easily removable panels for service • Exterior finish 18 Ga. G90 galvanized • Timer for electric defrost application is mounted • Unique placement of air intake louvers and pre -wired provides maximum air flow over compressors • Compressors are individually protected for cooler operation (circuit breakers) • Provided with weather -proof housing • Crank case heaters only come on when unit • Adjustable low pressure control is in off -cycle (reduces excess heat that the • Refrigerant lines piped for roof curb or ground compressors have to overcome during warm pad connections conditions and reduces energy consumption overall) "-"! �= ..,� 0 1 . o _ -. The flexibility of this unit makes it ideal for 1�1 walk -in cooler /freezer J applications, as well as ice machines I and other remote �ii ii� condenser needs. I I� I ;I� ' I� 3 • Multi -pak • Multi- circuit Condensing Multi -Pak Refrigeration System equipped with "headmaster" flooded condenser head The Multi -Pak refrigeration system will be ETL Listed to pressure control. The compressor /condenser circuit is UL Standard 1995, and may be located either on the roof sized to operate at an average temperature differential of the building, or, on a pad outside of the building. The (TD) between the ambient and condensing temperature condensing unit consists of compressors, multi- circuit of 20 °F. condenser, receivers, and electrical panel, all located Electrical Control Panel within a weatherproof outdoor housing. The evaporator The weatherproof electrical control panel is mounted coils supplied as part of the system, are complete with on the interior of the housing, and is fabricated of all of the accessories required. All of the component 18ga. Galvanized steel. The control panel is equipped parts, and required options and accessories will be with circuit breakers for each compressor system, mounted, wired, and piped as required. The system will contactors, auxiliary contacts, fuses, defrost time clocks, be manufactured to operate at either 208-230/1/60, and compressor starting components (for single phase or, 208-230/3/60. This unit can also be configured to operation). A color -coded wiring diagram is provided, support remote condenser loads. and mounted to the interior of the removable access Weatherproof Outdoor Housing panel. The wiring is color coded per the diagram, and is The Outdoor Weatherproof Housing is fabricated held in place with the appropriate fasteners. The entire of either 18 ga. G90 galvanized or 20 ga. stainless electrical system is protected by an exterior mounted steel. Each panel of the housing is removable for NEMA 3R rated fused disconnect switch. complete access to the interior of the unit for servicing. Refrigeration System Piping The perimeter rails are punched with openings to The refrigeration system piping is routed within the accommodate spreader bars for lifting purposes. housing so the installation contractor can pipe the Compressors and lines through the roof for roof curb applications or Multi- Circuit Condenser through protective bushings in the lower perimeter rail All compressors shall be Hermetic, Semi- Hermetic or for ground pad mounting. Each set of liquid /suction Scroll. Compressors are available to operate R -404A as lines will be identified as to the system they serve. All standard refrigerant but may be supplied with others refrigeration piping will be A.C.R. grade refrigeration when required. Each compressor will be charged copper, and will be held in place with tubing straps. All with the appropriate refrigerant oil as required. Each suction lines shall be covered with 1/2 "thick insulation compressor will be provided with discharge and suction tube. The entire condensing unit assembly shall be vibration isolation (vibrasorbers will be provided on tested at a minimum of 250 psig for leaks.The system semi - hermetic compressors). Each compressor system will be shipped with a SOpsig holding charge of will include a dual pressure control, liquid line filter /drier, dry nitrogen. sight glass w /moisture indicator, crankcase heater, and Evaporator Coils receiver tank. Each receiver tank will be provided with The evaporator coils will be mounted inside each walk - an isolation valve and access port at its outlet and are in compartment. Each evaporator coil will include a sized to accommodate the required refrigerant charge, thermostatic expansion valve (matched to the system without exceeding its capacity. The capacity can be capacity requirements), liquid line solenoid valve (for exceeded if the lines are too long. pump down), and a temperature control. If two or more The multi- circuit condenser system includes up to four evaporators are required for a system, the solenoid 1/2 HP, PSC energy efficient fan motors with a 24" fan valve will be mounted on each evaporator and the blade mounted in a formed venture fan orifice. The temperature control is shipped loose for field installation fan motor /blade assembly is protected by a coated in a central location. fan guard. Each compressor and condenser circuit is 4 Air - Cooled Refrigeration Systems MININILL Dimensional Data " Multi -Pak Model MC -1 Multi -Pak Model MC -2 1 .., y ------„,„„.,,, 40 1 x k.,_ lip1,-, 70" Y • 0 1,--,. 'N.A.,* 41" I — — I - - 51• 46 " J_i.�41 7:7.0.0.0 r: t - - - - - - 64" I r 70 " Multi -Pak Model MC -3 Multi -Pak Model MC-4 70" &a, - S�S l 71r , . iiii io - .--,..:, 4 61• —— —— —— —— I6' —— —— TT 46" -- - - 51" 1 - 1 - T � � ,-, ,-- --- -r 1 , , a1-.7 e 124"• 7p• --, Physical Data Maximum Maximum Number Number of Dimensions (In.) Approximate Total HP of Compressor Spaces Condenser Fans Length Width Height Weight (lbs.) $ 3 May contain up to 6 fractional 1 43" 63" 41" 750 h ermetic condensers $ 5 May contain up to 10 fractional 2 64 70" 51" 1100 h ermetic condensers. 14 7 May contain up to 14 fractional 3 94 70 S 1 14$0 hermetic condensers. 20 9 May contain up to 16 fractional 4 124" 70" 51" 2000 hermetic condensers. 5 Job Information Request Form Outdoor, Vertical Discharge Multi- Circuited Condensing Unit General Data Customer Location Sales Branch Contact Name Contact Phone Number Date Required Voltage Volts Phase I Cycle or HZ Fused Disconnect Switch Refrigeration Data Cabinet Evaporator Existing Temperature Temperature Required Capadty Requested RDI System Circuit In ° F In ° f Refrigerant Defrost Type in BTU Compressor STD Model A ' Required Information Note: Cooler Temperature Systems Will Be Sized for 16 HR Run Time or Less at 90° Ambient Note: Freezer Temperature Systems Will Be Sized for 18 HR Run Time or Less at 90° Ambient Standard Equipment: Accessory Data • Drier System Defrost Suction Suction Vibration Oil Type Accumulator Filter Eliminator Separator Sight Glass • Receiver with Shut -Off Valve • Head Pressure Control (Headmaster) • Vibration Eliminators on Semi - Hermetic Compressors • Suction and Discharge Shut -off Valve on Semi - Hermetic Compressors • Fixed Low Pressure Control • Fixed High Pressure Control • Defrost Clock (With Contactor and Circuit Protection When Needed) ▪ Single Point Electrical Connection • Circuit Breaker per Compressor Circuit 6 Warranty RDI Parts and Labor Warranty (11 -5 -04) General Conditions All invoices submitted for consideration under RDI's This warranty is issued only to the original purchaser -user parts and labor warranty must include the product serial at the original installation location and is in lieu of all number and must be received by RDI within 60 days of other warranties expressed or implied. the date of service. Following the expiration of the basic parts warranty, Parts Coverage replacement parts purchased from RDI shall be One (1) year from original start up date but no more warranted for parts replacement and shipping only for a than fifteen (18) months from ship date RDI will at it's period of ninety days from ship date. option repair, replace, or reimburse for local purchase Exclusions From Warranty Coverage of parts or assemblies found to be defective in material 1. Normal maintenance and adjustments such as or workmanship. Reimbursement for local purchase will temperature controls, thermal expansion valves, require a copy of the wholesale invoice and a maximum defrost timers and cleaning. 20% markup. During the first year defective compressors shall be exchanged over the counter by the compressor 2. Repairs due to unauthorized modifications of manufacturer's wholesaler. RDI will match the standard warranted equipment. 3 -year parts- and -labor warranty provided by Manitowoc 3. Damage or failure caused by improper installation, Ice on all components attached to the Manitowoc ice improper electrical supply, fire, flood, or other natural machine. disasters, acts of terrorism or war. Labor Coverage 4. Damage or delays occurring in transit. RDI systems are covered by a 30 day labor warranty for the replacement of component parts which are defective S. Parts or assemblies subject to misuse, abuse, neglect in material or workmanship. The warranty period begins or accidents. on the original start up date but no more than 18 6. Damage or loss of any products, property, loss of months from ship date. RDI reserves the right to pay income or profit due to malfunctioning of sold unit. maximum hourly rates equal to the average commercial hourly rates within that territory or region of the country. Extended Compressor Coverage If the optional four (4) year compressor warranty is purchased and the original compressor fails after the expiration of the one (1) year parts warranty. RDI will provide a replacement compressor for the condensing unit assembly. RDI will at it's option provide directly or authorize local purchase of the replacement compressor. If local purchase is authorized the wholesale invoice along with the serial tag from the original defective compressor shall be sent to RDI for reimbursement. In some instances the entire failed compressor may be required. I abor, freight /transportation, and additional parts /supplies are not covered. 7 Semi-Hermetic 20° TD _ Medium Temp - Semi - Hermetic @20 °TD THR #Of Circuits Circuiting Model Electrical RLA Amps IRA Amps Compressor THR Per Circuit Required Bundels MC -54M -2 208- 230/1/60 3.7 22.0 HAJB- 005E -CAV 7374 5922.00 1.25 2 MC -54M -3 208 - 230/3/60 2.2 13.0 HAJB - 005E -TAC 7374 5922.00 1.25 2 MC -74M -2 208- 230/1/60 6.1 36.0 KANB -007E -CAV 9057 5922.00 1.53 2 MC -74M -3 208 - 230/3/60 3.5 19.9 KANA- 007E -TAC 9057 5922.00 1.53 2 MC- 104M -2 208- 230/1/60 7.4 40.0 KARB - 010E -CAV 11732 5922.00 1.98 2 MC- 104M -3 208 - 230/3/60 4.3 27.0 KARA -010E -TAC 13797 5922.00 2.33 3 MC- 124M -2 208- 230/1/60 7.5 40.0 KAGB- 010E -CAV 12803 5922.00 2.16 3 MC- 124M -3 208 230/3/60 4.3 27.0 KAGA- 010E-TAC 12803 5922.00 2.16 3 MC- 154M -2 208 - 230/1/60 10.6 55.0 KAKB- 021E -CAV 21948 5922.00 3.71 4 MC- 154M -3 208- 230/3/60 6.8 50.0 KAKA- 020E -TAC 22155 5922.00 3.74 4 MC- 204M -3 208 - 230/3/60 6.6 46.0 ERCA- 021E -TAC 28096 5922.00 4.74 5 MC - 304M - 208 - 230/1/60 17.0 86.0 ERFB - 031E - CAB 40307 5922.00 6.81 7 MC- 304M -3 208 - 230/3/60 12.4 82.0 ERFA -031E -TAC 40307 5922.00 6.81 7 MC- 305M -3 208 - 230/3/60 14.2 82.0 3RAA- 031E -TAC 40110 5922.00 6.77 7 MC- 404M -3 208 - 230/3/60 21.8 141.0 NRB2- 040E -TFC 55420 5922.00 9.36 10 MC- 504M -3 208 - 230/3/60 22.3 120.0 2DC3- 050E -TFC 59485 5922.00 10.04 10 MC- 505M -3 208- 230/3/60 22.3 120.0 2003- 050E -TE( 70750 5922.00 11.95 12 _ 20° TD Low Temp - Semi - Hermetic @20 °TD THR # Of Circuits Circuiting Model Electrical RLA Amps LRA Amps Compressor THR Per Circuit Required Bundels MC -54L -2 208 - 230/1/60 3.6 24.0 KANB-005E -CAV 5200 5922.00 0.88 1 MC -54L -3 208- 230/3/60 2.2 13.2 KANA -005E -TAC 5200 5922.00 0.88 1 MC -741 -2 208- 230/1/60 5.6 36.0 KAMB- 007E -(AV 8375 5922.00 1.41 2 MC -741-3 208- 230/3/60 3.2 19.9 KAMA -007E -TAC 8375 5922.00 1.41 2 MC- 1041 -2 208- 230/1/60 6.9 40.0 KAJB- 010E -CAV 9168 5922.00 1.55 2 MC- 104L -3 208 - 230/3/60 4.6 270 KAJA -011E -TAC 9168 5922.00 135 2 MC- 154L -2 208 - 230/1/60 9.9 55.0 KALB - 015E -CAV 16262 5922.00 2.75 3 MC- 154L -3 208 - 230/3/60 6.6 50.0 KALA -016E -TAC 16536 5922.00 2.79 3 MC- 204L -2 208 - 230/1/60 14.7 102.0 EAVB -021E -CAV 22364 5922.00 3.78 4 MC- 2041 -3 208- 230/3/60 7.4 50.0 EAVA- 021E -TAC 22364 5922.00 3.78 4 M(- 3041 -2 208 - 230/1/60 16.7 105.0 LAHB- 032E -CAB 35467 5922.00 5.99 6 MC- 304L -3 208 - 230/3/60 12.8 112.0 LAHA - 032E -TAC 29924 5922.00 5.05 6 MC- 3051 -3 208- 230/3/60 16.8 102.0 2DF3F16KE- TFC -200 31743 5922.00 536 6 MC- 404L -3 208- 230/3/60 26.3 161.0 20L3 -040E -TFC 31348 5922.00 5.29 6 MC- 6011 -3 208 - 230/3/60 30.3 150.0 3DA3F28KE -TfC 45462 5922.00 7.68 8 8 Scroll 20° TD Medium Temp - Semi- Hermetic @20° TD THR #Of Circuits Circuiting Model Electrical RLA Amps LRA Amps Compressor THR Per Circuit Required Bundels MC- 139M2-2 208 - 230/1/60 10.0 41.0 2810KCE -PFV 16944 5922.00 2.86 3 MC- 149M2-2 208- 230/1/60 10.0 45.0 ZB11KCE -PFV 21116 5922.00 3.57 4 MC- 179M2-2 208- 230/3/60 12.9 54.0 ZB13KCE -PFV 22682 5922.00 3.83 4 MC- 199W-2 208- 230/1/60 15.7 61.0 1S15K4E -PFV 30384 5922.00 5.13 MC- 199M2-3 208 - 230/3/60 8.9 55.0 ZB15KCE -TF5 25130 5922.00 4.24 5 MC- 249M2-2 208- 230/1/60 16.4 73.0 ZS19K4E -PFV 32210 5922.00 5.44 6 MC- 249M2 -3 208- 230/3/60 9.7 63.0 IS19K4E -TF5 32210 5922.00 5.44 6 MC- 299M2-2 208 - 230/1/60 16.4 20.2 ZB21K4E -PFV 34364 5922.00 5.80 6 MC- 299M2 -3 208 - 230/3/60 11.1 77.0 ZS21K4E -TF5 34685 5922.00 5.86 6 MC- 349M1-3 208 - 230/3/60 13.6 88.0 ZS26K4E -TF5 43809 5922.00 7.40 8 MC- 399W-3 208 - 230/3/60 15.0 99.0 ZS30K4E -TF5 50060 5922.00 8.45 9 MC- 499M2-3 208- 230/3/60 21.4 123.0 2538K4E -TF5 68255 5922.00 11.53 12 MC- 599M2-3 208 - 230/3/60 22.1 172.0 ZS45K4E -TF5 68355 5922.00 11.54 12 MC- 749M2-3 208 - 230/3/60 30.0 189.0 2556K4E -TF5 90500 5922.00 15.28 16 MC- 999MZ -3 208 - 230/3/60 43.6 278.0 2575K4E -TF5 5922.00 0.00 MC- 1299M7-3 208 - 230/3/60 52.9 55.4 7S92K4E -TF5 5922.00 0.00 _ 20° TD Low Temp - Semi - Hermetic @20° TD THR #08 Circuits Circuiting Model Electrica RLA Amps LRA Amps Compressor THR Per Circuit Required Bundels MC- 19911 -2 208- 230/1/60 13.6 61.0 2F06K4E -PFV 17397 5922.00 2.94 3 MC- 19912 -3 208- 230/3/60 9.3 55.0 7F06K4E -TF5 17397 5922.00 2.94 3 MC- 24912 -2 208- 230/1/60 16.4 73.0 ZFO8K4E -PFV 18313 5922.00 3.09 3 MC 249L7 - 3 208 230/3/60 9.7 63.0 ZFO8K4E - TF5 18313 5922.00 3.09 3 MC 29912 - 2 208 230/1/60 16.4 88.0 ZFO9K4E - PFV • 19345 5922.00 3.27 4 MC - 29912 - 208 230/3/60 11.1 77.0 1F09K4E -TF5 19345 5922.00 3.27 4 MC- 349L7 -2 208- 230/1/60 20.7 109.0 ZF11K4E -PFV 24088 5922.00 4.07 4 MC- 34911-3 208 - 230/3/60 13.6 88.0 ZF11K4E - TF5 24088 5922.00 4.07 4 MC 39912 - 2 208 - 230/1/60 26.8 129.0 ZF13K4E - PFV 27553 5922.00 4.65 5 MC - 399L2 - 208 - 230/3/60 15.0 99.0 2F13K4E - TF5 27553 5922.00 4.65 5 MC- 4991/ -2 208- 230/1/60 31.8 169.0 ZF15K4E -PFV 30384 5922.00 5.13 5 MC- 49912 -3 208- 230/3/60 21.4 123.0 ZF15K4E -TF5 30384 5922.00 5.13 5 MC- 59912 -3 208- 230/3/60 23.9 156.0 2F18K4E -TF5 40770 5922.00 6.88 7 MC- 749L2 -3 208 - 230/3/60 30.0 189.0 2F24K4E -TWC 57207 5922.00 9.66 10 MC- 99912 -3 208 - 230/3/60 43.6 278.0 1F33K4E -TWC 63645 5922.00 10.75 11 MC 208 230/3/60 52.9 350.0 7F40K4E -TWC 79656 5922.00 13.45 14 9 M , Hermetic 20° TD _ Medium Temp - Semi- Hermetic @20 °TD THR 8 Of Circuits Circuiting Model Electrical RLA Amps LRA Amps Compressor THR Per Circuit Required Bundels MC -49M -1 115/1/60 10.1 51.0 R543C1E -IAA 10171 5922.00 1.72 2 MC - 49M - 208 - 230/1/60 5.4 24.1 RS43C1E -CAV 8665 5922.00 1.46 2 MC -69M -2 208- 230/1/60 6.1 40.0 RS55C2E -CAV 12954 5922.00 2.19 3 MC - 99M - 208 230/1/60 7.0 34.2 RS70C1E -PFV 16010 5922.00 2.70 3 MC -99M -3 208- 230/3/60 4.7 31.0 RS70C1E -TFC 13449 5922.00 2.27 3 MC- 149M -2 208- 230/1/60 9.6 59.2 CF04K6E -PFV 22070 5922.00 3.73 4 MC- 149M -3 208 - 230/3/60 6.8 52.0 CS10K6E -TF5 19035 5922.00 3.21 4 MC 199M - 2 208 - 230/1/60 10.9 56.0 CS12K6E - PFV 22990 5922.00 3.88 4 MC 199M - 3 208 230/3/60 7.5 51.0 0S12K6E - TF5 22450 5922.00 3.79 4 MC - 299M - 208 230/1/60 16.0 82.0 CS18K6E - PFV 33860 5922.00 5.72 6 MC 299M - 208- 230/3/60 8.8 65.0 CS18K6E -TF5 33150 5922.00 5.60 6 MC- 399M -2 208- 230/2/60 23.9 121.0 C527K6E -PFV 52053 5922.00 8.79 9 MC- 399M -3 208 - 230/3/60 15.6 105.0 CS27K6E -TF5 50885 5922.00 839 9 MC- 499M -3 208- 230/3/60 20.7 90.0 CS33K3E -TF5 59589 5922.00 10.06 10 20° TD _ Low Temp - Semi - Hermetic @20 °TD THR tt Of Circuits Circuiting Model Electrical RLA Amps LRA Amps Compressor THR Per Circuit Required Bundels MC -491 -1 115/1/60 4.1 30.0 AFT18C1E -IAV 5103 5922.00 0.86 1 MC -69L -2 208- 230/1/60 9.8 43.3 RS86C1E -PFV 10192 5922.00 1.72 2 MC -991 -2 208- 230/1/60 9.6 59.2 CF04K6E -PFV 6680 5922.00 1.13 2 MC -99L -3 208 - 230/3/60 6.8 52.0 CF04K6E -TF5 6271 5922.00 1.06 MC- 149L -2 208 - 230/1/60 11.4 59.2 CF06K6E -PFV 10905 5922.00 1.84 2 MC 1491 - 208 - 230/3/60 7.0 52.0 CF06K6E - TF5 10328 5922.00 1.74 2 MC 1991 - 208 230/1/60 16.7 87.0 0F09K6E -PFV 15751 5922.00 2.66 3 MC- 199L -3 208 - 230/3/60 10.2 72.2 0F09K6E -TF5 15534 5922.00 2.62 3 M(- 2491 -2 208 - 230/1/60 16.7 87.0 CF09K6E -PFV 18901 5922.00 3.19 4 MC 249L - 3 208230/3/60 10.2 72.2 CF09K6E - TF5 18640 5922.00 3.15 - MC- 299L -2 208 - 230/1/60 20.5 105.0 0F12K6E -PFV 25448 5922.00 4.30 5 MC- 2991 -3 208 - 230/3/60 12.3 85.0 0F12K6E -TF5 25448 5922.00 4.30 5 MC 404L - 3 208 - 230/3/60 26.3 161.0 2DL3 - 040E - TFC 34766 5922.00 5.87 6 10 R D I RDI 2915 TENNESSEE AVE NORTH, PARSONS, TN 38363 • 1- 877-759 -9019 • FAX 1- 731 - 847 -9012 SOLUTIONS Canitowoc AD! provides many of the operational solutions from Manitowoc Foodservice, a global company dedicated to bringing value to foodservice operators by equipping them with highly individualized real -world answers that enhance menus, service, profits and efficiency. To learn how Man'towoc Foodservice and ns leading brands can equp you, visit o:.r global web site at www.manitowocfoodservice.co^ then find the regional or local resources ava fable to you. Can towoc ©2009 Manitowoc Fuudservice except where explicitly stated otherwise. All rights reserved. 361/D 1/10 MODEL JO /h94-D1rmdr dNene99re Unit CONECnOro 412Es MR AMR 1 mn un - art MO 2 — BIM OM I-M 01801150801 imioo e i 1 N 'lla m.� .. ems O / l l . �. ■ / 9 "- ..0.. . t •I� - a �•:� > ' . :' . .... 1 11 mans NW owes= RD I. 410 to • l V . E.. M!. 1 IS ~ w) •6•16 . C i pafOt �-� 4 - wu 1P1700 ,.F ne L0 %I 05 o , to n Wm Wm Flan • • r r r oe 1 • —1 I I moon van rR :':::Co ml ¢ *,m "' a -trf r -u.l I.1 v i l ! w 5 •. • , ,e eT 7,..., 'Arm IMO e �I ; � . T m�H=U rw x�� > ' i�! :cam 1,0 I . e ma�� FAH *� / \I m i I LWLND 0 A . AYt w /TIMER . c q 1 xw�A • ",rp„ r rnwoeon eaw.exT ruxur,c *w. s �II E . M w ,<wer„� r•r*c UNDER w,wRs � eoo. vErer UNIT COOLER tts1:15.60.711 UNIT • MILER 208 - 230/ 8.18A11.2 8.18A11.2 llEe[xli 7E TORISE SOLENOID OR IRO Y 'NOTE FUSED DISCONNECT IN *FAIRER U1411 'MOO. VIM HOLES 9. - VALVE INC/ . IS PROOF NINA ENCLOSURE ___,. CONDENSING UNIT ASSEMBLY F r S • I- i • f �t `;1 f -, ....:, J -, _ •' _ CC WIRE TO TO J/- - - •'' l� _. TIMER AT ± —�- . «1 . , 1 , • ; - • , 1 • -' SECTION 8-8 /1•116111. EVAP COIL 1 7 • iii � ••6••161• 2. PROVIDE SW • • "S R •N miam io ii •�� ���� MC3 FRAME £ SECTION DETAIL Via; HOW E � I � , , 1..140 TORE r mom 2 149MCVD 1499CVD 999 E991 HOT . COED CONDENSER COIL CIRCUITING PITCHAFTER.i "`ATEN. L = _ L aawEnl2�A „,„,,Y To. Ea1rn _ — —a 0111E011XECr sAlicH WlRIAC DIAGRAM 1 FIRING DIAGRAM I 288- 1.90/1/60 054/80 ELEC DEFROST EVAPORATOR AIR DEFROST EVAPORATOR WNCEMIM,O 041 ELECTRICAL BOI wn-rw,nw. ; 1 AIR DEFROST I - - - n -...-A. -...-A. � � - TIMER I1 D�tOST TIMER I 1 1 1 1 1 ' I 1 -, T e I .. �i ES I�.�I I , 1 I@ 11 I�I I I I - - IE I I I .. 6r. ' O 1 1! -j f: :_j " _: 1 � ) ^ � SY V � 1 tl ji; ' 7 �/ '— FAIN CAP ��IIr��� • - �� �- �� I III � ! 1 DRAIN IIHR OXTAIL r� E 111 -c' - _. I I _ 1E L � _ � �� 111 e Gvl ITEMS PROVIDED INCLUDE , , , :�� 1. 3 Fan Multi-Circuit Condenser 2. (3)Cond Fan Motor -1/2 HP r2[411 > G 1. : I re 0 1 ., , w a ► 1 4 p 5. liquid line sol1enoid valve (i ' 4. Li9 d Line Filter Drier J r�stalled -evap) ,'N - _ _ _ 6. Thermostat (Installed -Evap) N -' 7. Headmaster Head Pressure Contrcl 1!i rr 6. Hermetic Compressors - Copeland 9. Crankcase Heaters � I _ .4 10. Hi/Lo Pressure Control (ad ustab e) t I I t I ' 1 !I 1 1 11 ! 11 11. Outdoor Housing -G90 Galvanized - 12. Crankcase Heater e... ��� 13. Circuit Breaker ea. Unit .1.1 I I I S I I I I �� j • � � -- ~- Y - - -- -� -~ e - ~� ~1 Z 14. Single Point Elec, Fused Dlsa.(Mtd.) I 4 I I I .. w _ a . 0 r ' - E @ �7 [ r t1 \ � I5. Timer mounted on all units CONDE = . w {* . REMOTE Y2 99Y/IW1L1D/1/91CYD/blIL9D /E996 Dh9 WIRE TO ICE FAN MOTORS MC VD MC- 149MCVD MC- 149MCVD MC -99M 11C -299L L S S 147 CARL'S J17 - r1°I81° EVAP MAKER 11a1rrr ncAR DR COIL remsm..R. -- °• - --- w TERMINAL CONDENSING UNIT WIRING DIAGRAM V°T"`4°' I`m"'0°" 7 1 Col RID A/P BOARD m rs10r MEM - - e RDI 866618 -- -- -..-,I111116111111 11TSIOWII1 N S a F 4