Plans
FP50011-CC ?A 1.035s sw Ca4C t L 4 RECEIVED ' - Global Project Values: ft hsi SILENT Project Name: FISHERMANS Standby Hours: 24 KNIGHT Project ID: A m Mins:I , §.„ Prepared By: JASON SWEET Derating Factor:I 12ONr 5495 Power Expander Calculations Date: 2/15/2011 I AP Voltage Drop Warning Installed Battery: 7 Hour Threshold °r6 :1 15 Panel ID: 5495(1) I Model: Silent Knight 5495 Power Expander Max Circuit Current: 3 Amps Location: BY FACP Volts: 24 VDC Max Panel Current: 6 Amps Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ 0 /0Drop Ckt.# Circuit Name Standby Alarm & Type 1000 Ft. One Way Ohms EOL li 1 1.1.1 0.000 1.284 #14 Solid 2.52 330 1.66 18.26 10.47% 2 1.1.2 0.000 1.074 #14 Solid 2.52 250 1.26 19.05 6.63 %'.' 3 1.1.3 0.000 0.416 #14 Solid 2.52 90 0.45 20.21 0 92% 4 SPARE 0.000 0.000 #14 Solid 2.52 0 0.00 20.40 0 00% Aux 5495(1) Aux Power Out 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% p 5495 5495 Power Expander 0.075 0.205 2.774 (Amps) Total Output Power Required I Total Standby Current (Amps) 0.075 2.979 Total Alarm Current (Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes / 60 (5 Mins) Total Standby AH Required 1.800 0.248 Total Alarm AH Required Total Combined AH Required 2.05 Wire resistances are based upon an ambient temperature of 72 degrees F. Because of Multiply By The Derating Factor 1.20 the minimal difference between solid and stranded wire no differential was made. Minimum Battery AmpHours Required 2.46 Panel ID: 15495(2) Model: Silent Knight 5495 Power Expander Max Circuit Current: 3 Amps Location: Volts: 24 VDC Max Panel Current: 6 Amps Ckt.# Circuit Name Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop Standby Alarm & Type 1000 Ft. One -Way Ohms EOL 1 5495(2) Circuit 1 _ 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% 2 5495(2) Circuit 2 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% 3 5495(2) Circuit 3 0.000 0.000 #14 Solid 1.59 0.00 20.40 0.00% 4 5495(2) Circuit 4 0.000 0.000 #14 Solid 1.59 0.00 20.40 0 . •' Aux 5495(2) Aux Power Out 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% 5495 5495 Power Expander 0.075 0.205 0.000 (Amps) Total Output Power Required Total Standby Current (Amps) 0.075 0.205 Total Alarm Current (Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes / 60 (5 Mins) Total Standby AH Required 1.800 0.017 Total Alarm AH Required Total Combined AH Required 1.82 Wire resistances are based upon an ambient temperature of 72 degrees F. Because of Multiply By The Derating Factor 1.20 the minimal difference between solid and stranded wire no differential was made. Minimum Battery AmpHours Required 2.18 RECEIVED FEB 18 2011 CITY OF TIGARD BUILDING DIVISION ® "'' Circuit Configuration Project Information Project Name: 0 Project ID: 0 Prepared By: 0 Date: 1/0/1900 Ckt. Number: 1 Panel ID: 5495(1) Ckt. Name: 4.1.1 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 3 SS SCW 115 0.000 0.210 0.000 0.630 3 SS PC2W 115 0.000 0.218 0.000 0.654 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 , 0.000 0.000 Totals 0.000 1.284 Ckt. Number: 2 Panel ID: 5495(1) Ckt. Name: 4.1.2 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 2 SS SCW 115 0.000 0.210 0.000 0.420 3 SS PC2W 115 0.000 0.218 0.000 0.654 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0.000 1.074 Ckt. Number: 3 Panel ID: 5495(1) Ckt. Name: 1.1.3 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm 1 SS PC2W 115 0.000 0.218 0.000 0.218 3 SS SW 15 0.000 0.066 0.000 0.198 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0 000 0 416 Ckt. Number: 4 Panel ID: 5495(1) Ckt. Name: 1.1.4 Max Circuit Current: 3 Amps Qty Device Current Draw Each Current Draw Total Standby Alarm Standby Alarm Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 Unused 0.000 0.000 0.000 0.000 0.000 0.000 Totals 0 .000 0.000 FIRE SYSTEM ACCESSORY Model 5495 2 . ___ Distributed Power Module �` In an emergency, ..,.. s ,,,,,::„. ` you need maximum power. ti p .. ., k 4, ''I. The 5495 Distributed Power Module by Silent Knight is the most powerful and cost- effective power supply available today. It delivers 6 amps of notification appliance circuit power and built -in synchronization for appliances from System Sensor®,Gentex ®, AMSECO ®, Wheelock and Faraday — what you need to drive power -hungry components like ADA notification appliances. The 5495's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. And, ADA retrofits are easier and less expensive with the 5495 because it integrates into current systems without the costly investment in new components. For the most sophisticated and cost - effective notification power supply available, you need the 5495. Call Silent Knight today for more information at 1- 800 -446 -6444. Model 5495 • Independent trouble relay Distributed Power Module • AC loss delay option shuts off power The 5495 is a 6 amp notification power to non - essential high- current expander that provides its own AC accessories like magnetic door power connection, battery charging holders circuit, and backup battery for use with • Built -in synchronization for fire and security controls such as the appliances from System Silent Knight Model 5208 Fire Control Sensor®,Gentex®, AMSECO ®, /Communicator. The 5495 is the cost- Wheelock and Faraday C. effective solution for powering • notification appliances required by the Stand alone operation Americans with Disabilities Act (ADA). • Lightweight design adds to ease of The 5495 has built -in ANSI cadence installation and reduces shipping pattern, which can upgrade older costs control panels that lack cadence • Operates with most polarized, UL capability. Listed notification devices Features • UL 864 & 1481 listed It, ; • UL Listed for 6 amps of notification • CSFM approved power Model 5495 • ANSI Cadence pattern output • Power supply's advanced switch capability built -in Distributed Power Module mode design reduces damaging heat and manages power up to 50% Connection to Local Fire Control more efficiently than other systems The 5495 may be connected to a local 4.7k0 end -of -line resistors provided. • Dip switches allow for easy fire control which utilizes Class A or Since the 5495 draws very little power reconfiguration Class B type notification circuits from the control, it is possible to • 24 VDC filtered output voltage operating between 9 and 32 VDC. The connect one 5495 to each notification control panel's notification circuit is circuit on the control panel and still • Four power- limited notification provide full supervision of the outputs; 2 Class A or 4 Class B, or 1 connected to one of the inputs on the 5495. The control panel's notification notification circuits all the way back to Class A and 2 Class B the control panel. • Additional continuous auxiliary circuit end-of-line resistor is also p output connected across two terminals on the 5495, which provides supervision SILENT • 3 amps per output circuit between the 5495 and the fire control • 2 inputs; 2 Class B or 2 Class A panel. Polarized audible and /or visual it KNIGHT • Ground fault detector /indicator notification devices are then connected to the 5495 signal circuits using the by Honeywell FIRE SYSTEM ACCESSORY Model 5495 Distributed Power Module 2 Supervision Current: Input The 5495 supervises a variety of Standby 75 mA voltage range: 9 - 32 VDC functions including: Alarm 175 mA Battery charging • Low AC power Auxiliary capacity: 33.0 AH • Low battery condition power circuit: 1 Ambient temp.: 32° to 120° F • Earth ground fault Notification 0° to 49° C • Auxiliary output power limit circuits: 4 Mechanical condition Output Dimensions: 12.25" W x 16" H x • EOL supervision trouble or configuration: 2 Class A (Style Z) 3" D (30.88 cm W power limited condition at an 4 Class B (Style Y) x 40.64 cm H x output (1 Class A & 7.62 D cm) When a trouble condition occurs, 2 Class B) Indicator Lights the 5495 creates a trouble Amps per AC power on : Green condition on the host control signal output circuit: 3.0 (6.0 amps total) to which it is connected. the p ( p ) Battery trouble: Yellow 5495 still maintains the ability to be Notification Ground fault: Yellow activated by the host control. In circuit output: 20.4 to 27.3 VDC Aux trouble: Yellow 3.0 amps the 5495 provides a Form @ ps each, C trouble relay output as an 4.7 kS2 EOL Output alternative to using the notification resistor required troubles (1 -4): Yellow circuit trouble. on each Class B Approvals: Electrical Specification circuit UL: 864 & 1481 AC input: 120 VAC at 2 amps No. of inputs 2 NFPA: 72 Input CSFM Output: 24 VDC at 6 amps configuration: 2 Class B or 2 Class A Model 5495 Block Diagram Signal Circuit Output Signal 1 Signal 1 Input Distributed Signal 2 Signal Circuit Output Signal 2 Power Input Module 5495 Signal 3 (Optional) Signal 4 120 VAC Aux. Power Trouble Output Local Fire Control (Alternative to notification circuit trouble.) SILENT This document is not intended to be used for installation purposes. We try to MADE I N AMERICA lc KNIGHT keep our product information up -to -date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350395 Rev B, 12/05 subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369 -4927. Copyright © 2005 Silent Knight Phone: (800) 328 -0103, Fax: (763) 493 -6475. • SYSTEM SENSOR Selectable Output Notification Devices • SpectrAlert' Advance selectable - output horns, strobes, and horn /strobes are rich with features guaranteed to cut installation times and maximize profits. SPECTFAIert A D V A N C E The SpectrAlert Advance series of notification appliances is Features designed to simplify your installations, with features such as: plug in Plug-in design designs, instant feedback messages to ensure correct installation of individual devices, and eleven field - selectable candela settings for • Same mounting plate for wall- and ceiling -mount units wall and ceiling strobes and horn /strobes. • Shorting spring on mounting plate for continuity check before installation More specifically, when installing Advance products, first attach a universal mounting plate to a four -inch square, four -inch octagon or 'Captive mounting screw double -gang junction box. The two -wire mounting plate attaches to •Tamper resistance capability a single gang junction box. • Field selectable candela settings on wall and ceiling units: 15, 15/75, Then, connect the notification appliance circuit wiring to the SEMS 30, 75, 95, 110, 115, 135, 150, 177, 185 terminals on the mounting plate. • Automatic selection of 12 or 24 volt operation at 15 and 15/75 candela Finally, attach the horn, strobe or horn /strobe to the mounting plate . Outdoor wall and ceiling products by inserting the product's tabs in the mounting plate's grooves.The device will rotate into position, locking the product's pins into the • Outdoor products rated from -40° to 151°F mounting plate's terminals. The device will temporarily hold in place • Minimal intrusion into the back box with a catch until it is secured with a captured mounting screw. SpectrAlert Advance products allow you to choose: •Horn rated at 88+ dbA at 16 volts • 12 or 24 volts • Rotary switch for tone selection • At 24 volts, 15, 15/75, 30, 75, 95, 110, 115, 135, 150,177 or 185 .3 horn volume settings candela by way of rear - mounted slide switch and front viewing window • Electrically compatible with existing SpectrAlert products • Horn tones and volume by way of rotary switch The SpectrAlert Advance series includes outdoor notification Agency Listings appliances. Outdoor strobes and horn /strobes (two wire and four wire) are available for wall or ceiling. Outdoor horns are available for SIGNAUNS ♦`T a 7125 - 1653:186 (Indoor strobes) wall only. All System Sensor outdoor products are rated between U� ® MEA t r 7125 - 8- 7116165533::18189 71outdoorsrmbes7 minus 40 degrees Fahrenheit and 151 degrees Fahrenheit in wet or approve 1 bes) s�'^ 7125- 1653:189 (horns) ro s) LISTED APPROVED �� � dry applications. 3n23572 MEA452 -05 -E SpectrAlert Advance Specifications Architect /Engineer Specifications General SpectrAlert Advance horns, strobes and horn /strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4 -inch octagon back box or double -gang back box. Two-wire products shall also mount to a single -gang 2 x 4 x 11-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync-Circuit Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync - Circuit Module, 12 -volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts; 24 -volt rated notification appliance circuit outputs shall operate between 17 and 33 volts, Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full -wave rectified, unfiltered power supply. Strobes and horn /strobes shall have field - selectable candela settings including 15,15/75, 30, 75, 95,110,115, 135, 150, 177,185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary - signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn /Strobe Combination The horn /strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn /strobe shall be wired as a primary - signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three - pattern and a non - temporal (continuous) pattern.These options are set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder.The horn on horn /strobe models shall operate on a coded or non -coded power supply. Outdoor Products SpectrAlert Advance outdoor horns, strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fahrenheit. The products shall be listed for use with a System Sensor outdoor /weatherproof back box with half inch and three - fourths inch conduit entries. Synchronization Module The module shall be a System Sensor Sync - Circuit listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn/strobe models over a single pair of wires. The module shall mount to a 4'X6 x 416 x 2A -inch back box The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical /Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) K Series Operating Temperature -40°F to 151°F ( -40°C to 66°C) Humidity Range 10 to 93% non-condensing (indoor products) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR' Operating Voltage Range' 8 to 175 V (12V nominal) or 16 to 33 V (24 nominal) Input terminal wire gauge 12 to 18 AWG Ceiling mount dimensions (including lens) 6.8 diameter x 2.5" high (173 mm diameter x 64 mm high) Wall mount dimensions (including lens) 5.61 x 4.7W x 25D (142 mm L x 119 mm Wx 64 mm D) Horn dimensions 5.61 x 4.7W x 13D (142 mm L x 119 mm Wx33 mm D) Notes: 1. Full Wave Rectified (FWR) voltage is a non - regulated, time varying power source that is used on some power supply and panel outputs. 2. P, 5, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. A05-0395-002 UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) UL Max. Horn Current Draw (mA RMS) 8 -17.5 Volts 16 -33 Volts 8 -17.5 Volts 16 -33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela Range 15/75 142 148 77 81 Temporal Medium 44 49 58 69 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non- temporal High 57 56 69 75 95 NA NA 181 176 Non - temporal Medium 42 50 60 69 110 NA NA 202 195 Non - temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2 -wire Horn /Strobe, Standard Candela Range (15 -115 cd) 8 -17.5 Volts 16 -33 Volts DClnput 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non - temporal High 141 152 91 100 116 176 201 221 229 Non - temporal Medium 133 145 75 85 102 163 187 207 216 Non - temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non - temporal High 142 161 103 112 126 181 203 221 229 Non - temporal Medium 134 155 85 95 110 166 189 208 216 Non - temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current Draw (mA RMS), 2 -wire Horn /Strobe, High Candela Range (135 -185 cd) 16 -33 Volts 16 -33 Volts DClnput 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non - temporal High 255 270 303 309 Non - temporal High 233 248 275 281 Non - temporal Medium 242 259 293 299 Non - temporal Medium 219 232 262 267 Non - temporal Low 238 254 291 295 Non - temporal Low 214 229 256 262 Horn Tones and Sound Output Data Rotary Horn and Horn /Strobe Switch Settings Horn and Horn /Strobe Output (dBA) Setting Repetition Rate dB Level Switch 8 -17.5 Volts 16 -33 Volts 1 Temporal horn High Position Sound Pattern dB DC FWR DC FWR 2 Temporal horn Medium 1 Temporal High 78 78 84 84 3 Temporal horn Low 2 Temporal Medium 74 74 80 80 4 Normal horn High 3 Temporal Low 71 73 76 76 5 Normal horn Medium 4 Non - temporal High 82 82 88 88 6 Normal horn Low 5 Non - temporal Medium 78 78 85 85 7* Externally coded High 6 Non - temporal Low 75 75 81 81 8* Externally coded Medium 7* Coded High 82 82 88 88 9* Externally coded Low 8' Coded Medium 78 78 85 85 9* Coded Low 75 75 81 81 *Settings 7, 8, and 9 are not available on 2 -wire horn /strobe. A05 -0395 -002 • SpectrAlert Advance Dimensions 4.7 "" 1 ■ al 6.8," '.....=:=:." ' ' r______ 1 1 ,..._ jam_ r -,-- _ ,;,, / 1 I4--2.5 =--■ SpectrAlert Advance Ordering Information Model Description Model Description Wall Horn /Strobes Ceiling Horn /Strobes (cont'd.) P2R *t 2 -wire Horn /Strobe, Standard cd', Red PC2W *t 2 -wire Horn/Strobe, Standard cd, White P2RH* 2 -wire Horn /Strobe, High cd, Red PC2WH*' 2 -wire Horn/Strobe, High cd, White P2RK• 2 -wire Horn/Strobe, Standard cd, Red, Outdoor PC4R 4 -wire Horn/Strobe, Standard cd, Red P2RHK* 2 -wire Horn/Strobe, High cd, Red, Outdoor PC4RH 4 -wire Horn /Strobe, High cd, Red P2W* 2 -wire Horn/Strobe, Standard cd, White PC4RK 4 -wire Horn /Strobe, Standard cd, Red, Outdoor P2WH* 2 -wire Horn/Strobe, High cd, White PC4RHK 4 -wire Horn/Strobe, High cd, Red, Outdoor P4R* 4 -wire Horn /Strobe, Standard cd, Red PC4W 4 -wire Horn /Strobe, Standard cd, White P4RH* 4 -wire Horn/Strobe, High cd, Red PC4WH 4 -wire Horn /Strobe, High cd, White P4RK 4 -wire Horn /Strobe, Standard cd, Red, Outdoor Ceiling Strobes P4RHK 4 -wire Horn /Strobe, High cd, Red, Outdoor SCR* Strobe, Standard cd, Red P4W* 4 -wire Horn /Strobe, Standard cd, White SCRH* Strobe, High cd, Red P4WH* 4 -wire Horn /Strobe, High cd, White SCRK Strobe, Standard cd, Red, Outdoor Wall Strobes SCRHK Strobe, High cd, Red, Outdoor SR *t Strobe, Standard cd, Red SCW*t Strobe, Standard cd, White SRH *t Strobe, High cd, Red SCWH *t Strobe, High cd, White SRK Strobe, Standard cd, Red, Outdoor Horns SRHK Strobe, High cd, Red, Outdoor HR Horn, Red SW" Strobe, Standard cd, White HRK Horn, Red, Outdoor SWH* Strobe, High cd, White HW Horn, White Ceiling Horn /Strobes Accessories PC2R* 2 -wire Horn /Strobe, Standard cd, Red BBS -2 Back Box Skirt, Wall, Red PC2RH* 2 -wire Horn /Strobe, High cd, Red BBSW -2 Back Box Skirt, Wall, White PC2RK 2 -wire Horn /Strobe, Standard cd, Red, Outdoor BBSC -2 Back Box Skirt, Ceiling, Red PC2RHK 2 -wire Horn /Strobe, High cd, Red, Outdoor BBSCW -2 Back Box Skirt, Ceiling, White Notes: *Add " -P "to model number for plain housing (no °FIRE" marking on cover), e.g., P2R -P t Add " -SP "to model number for 'FUEGO" marking on cover, e.g., P2R -SP *"High cd; refers to strobes that include 135, 150, 177, and 185 candela settings. "Standard cd " refers to strobes that include 15,15/75, 30, 75, 95,110, and 115 candela settings. *� SYSTEM 02005 System Sensor. 3825 Ohio Avenue • St. Charles, IL60174 A,duct �acanamw ttochangewithoutnouce. as y,co„sen,,,tcomtor �� SENSOR Phone: 800-SENSOR2 • Fax: 630- 377 -6495 current product information. induding the latest version o r tints data sheet. A05-0395-002. 7/06 • *1659