Loading...
Plans BUILDING INFORMATION TENANT INFORMATION 01) `'/ OWNER: PACIFIC REALTY ASSOCIATES, L.P. TENANT: PROTECTION ONE ALARM TENANT IMPROVEMENT for � #3082 15350 SW SEQUOIA PKWY #300 MONITORING, INC. PORTLAND, ORE 97224 PROTECTION ONE ALARM r IN W. HANSON ' 3 OCCUPANCY AREAS & LOADS: - ' (503) 624 -6300. (PHONE) B 2,313 SF 23 OCC - MONITORING, INC. UCLA AM S, OREGON, (503) 624 -7755 (FAX) S -2 536 SF 1 OCC • 9 � c�0 TOTAL 2,849 SF 24 OCC I, v BLDG. #: PBC BLDG. H (pbc198) PROJECT NARRATIVE OF 0 � NUMBER OF EXITS REQUIRED • CONST. TYPE.: V — FULLY SPRINKLED B 1 EXITS 1 PROVIDED PROJECT CONSISTS OF MINOR TENANT IMPROVEMENT WORK IN A 2,849 SF OF EXISTING PROJECT #10680 S - 1 EXITS 1 PROVIDED OFFICE/WAREHOUSE SPACE WHICH INVOLVES AN OPEN OFFICE AREA AND SERVER ROOM. WORK SHALL INCLUDE BUT NOT BE LIMITED TO DRYWALUMETAL STUDS, DOORS /FRAMES AND PAINTING. ALL WORK TO THIS BUILDING HOUSES TWO SEPARATE TENANTS INCLUDING THIS TENANT. THE MEET ADA REQUIREMENTS. EXISTING BUILDING IS A SINGLE STORY BUILDING OF 21,180 SF AND IS FULLY r SPRINKLERED. THERE IS FRONTAGE ON ALL FOUR SIDES OF AT LEAST 60 FEET. WORK INCLUDED BUT PERFORMED UNDER SEP. PERMIT o if ACTUAL BUILDING AREA TOTALS FIRE PROTECTION SPRINKLERING a HEATING, VENTILATION & AIR CONDITIONING WORK c° 0 B OCCUPANCY = 15,471 SF ELECTRICAL WORK, BOTH LINE VOLTAGE AND LOW VOLTAGE � 1 a if S2 OCCUPANCY = 5,709 SF Q a cv a TOTAL BUILDING = 21,180 SF . DRAWING INDEX • 0 O rn o 0 0 I- A -1 GENERAL INFORMATION, FINISHES, NOTES & LEGEND 2 O ti MIXED OCCUPANCY - NON - SEPARATED OCCUPANCIES. (IBC 508.3.2) A -2 GENERAL NOTES, BUILDING PLAN & DETAIL i W c(i) O 'T 4 J o a A -3 PARTITION & POWER PLAN § 0 O co co la BASIC AREA (B OCC, V -B) = 9,000 SF V SPRINKLER INCREASE (300 %) = 27,000 SF A-4 REFLECTED CEILING PLAN c o o o Q YARD INCREASE (75% BASIC AREA) = 6,750 SF M cc LL r D- D. u_ 4 TOTAL ALLOWABLE AREA = 42,750 SF • 42,750 SF > 21,180 SF - NON - SEPARATED OCCUPANCIES ALLOWED WITH NO OCCUPANCY SEPARATION REQUIREMENTS 508.3.2.3. SW 72ND AVENUE • W CC - W ' `/ l�rml nn�nn n I Im ^^^^^a __ Z Z 0 �= r rte` W 1 „' J p I I I f �_ �Q 1 CITY OF TIGARD o Q 1 I ' , _ App r Z CO CM C onditionally Approved [ ] Q z 2 VI o � T See Letter to: Follow [ ] _ °' _ Attach h 6 - Per Num • `O ,• 0 m Q .�. 0 \ ....4 —f o Ad. - • • ' a '? e ru.� O o z ":„„ T , rs I I 1 By: ∎ Date: � - T ! 1-- U I- o t 4( - 0,..c . o_ 4� Occupancy - REVISION , � �� Construction , Q� BUILDING % ti LOCATION Rated Corridor 1. Energy Code i ,3,9 ibl>tt� ( .�F>a 2. %cL ecT Ao i�� 1 LOCATION MAP TO TBC I & y PERMIT SET DATE: 11/30/10 OF FICE COPY A -1 NOT TO SCALE Q BUILDING DEPARTMENT USE 1 GENERAL NOTES ,--) ,3; ,5; �a; ��`C' _ #3082 'f r 1. ALL CONSTRUCTION WORK SHALL BE DONE IN COMPLIANCE WITH THE LATEST r j - _; - - - - I -- -- — 7324 t # A EDITION OF THE INTERNATIONAL BUILDING CODE AS AMENDED BY THE STATE OF MA TIN W. HANSON OREGON AND ALL OTHER STATE OR LOCAL CODE REQUIREMENTS THAT APPLY. : C 1 ! I 'poi I I ; -9, 11.., ....3 OREGON 2. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON ' ;. ' I r 7 340 ; a I Is � . � �_ , �+ DRAWINGS AND AT THE EXISTING BUILDING AND NOTIFY ARCHITECT OF ANY , • NN` I ' i in B ; I 1 mut' 9J� v DISCREPANCIES PRIOR TO STARTING THE WORK. OF O�� clw 3. CONTRACTOR SHALL KEEP THE AREA OF WORK FREE OF GARBAGE AND DEBRIS c '� j B - ' b - __'¢ - - PROJE #10680 ON A DAILY BASIS INCLUDING DOCK ACCESS AREAS. Mr M U I ' IP 0 4. CONTRACTOR SHALL KEEP THE ROOF FREE OF DEBRIS (I.E. NAILS, SCREWS) AT ; __ ' i H ►�� 1 _ I r ALL TIMES. I r 7,S • i o Q ., o 5. ALL GYPSUM BOARD TO BE A MINIMUM OF 5/8" THICK VERTICALLY ATTACHED TO g S2 ; N * rn W 3 5/8" METAL STUDS 24" O.C. WITH 1" TYPE S -12 SCREWS 12" O.C. UNLESS OTHERWISE ;� - � - -. - o -� - - e v a NOTED. I r- ___ IInlu11i S2 +e e U n I U -- j - - - -- �e � Q ' I S2° e Q I Q • 6. IN FINISHED SPACES FURR -OUT BUILDING COLUMNS AND EXTERIOR WALLS WITH I I I I 5/8" GYPSUM BOARD OVER METAL STUDS. (-6)-- MI NDXR3 41 ERK . �„ • 0 O 18 M ti Z 1- AREA OF WORK as Wo c Dr- 5 7. ACOUSTICAL CEILING SYSTEMS: SUSPENSION SYSTEM TO BE EXPOSED METAL N I u) 0 N N j Q T -BAR, PREFINISHED WHITE, TO COMPLY WITH U. S. 0. STANDARDS. INSTALL LATERAL 1 BUILDING PLAN g C° m F -' BRACING PER CODE. A - SCALE 1" = 40' e o M o 'Cr) 8. ALL DOORS SHALL BE 3'- 0 "x7' -0 "x1 3/4" SOLID CORE WOOD UNLESS NOTED T 0 a x IL OTHERWISE. DOOR HARDWARE SHALL BE SCHLAGE AL SERIES. BUTTS, CLOSERS, Q AND OTHER HARDWARE TO MATCH BUILDING STANDARD. DOORS WITH CLOSER USE D- SERIES \ 3 1/2" 24 GA METAL STUDS AT 10' -0" O.C. TO BUILDING STRUCTURE ABOVE FOR 9. HVAC TO BE A BALANCED, DESIGN -BUILD SYSTEM. MECHANICAL CONTRACTOR UNSUPPORTED WALLS LONGER THAN 12-0" TO SUBMIT ZONE MAP AND THERMOSTAT LOCATIONS FOR TENANT /LANDLORD +/- 45° x FASTEN EACH END W/ (1) #8 SHEET METAL SCREW APPROVAL BEFORE CONSTRUCTION. tl • w •. � 1 f . BLOCKING TYP. AT FASTENING POINTS • EC 10. PROVIDE SPRINKLERS BELOW SUSPENDED CEILING PER CODE. SPRINKLER )( l • i -- - 3 1/2" BATT INSULATION 2' ON EACH SIDE OF WALL w Lu HEADS SHALL BE CENTERED IN 2 X 2 CEILING TILE. LAYOUT OF SPRINKLERS BY e O W CONTRACTOR. • SUSPENDED CEILING U Q Z u)o� 11. PROVIDE LABEL FOR EACH CIRCUIT AT PANEL FOR IDENTIFICATION PURPOSES. 3 1/2" MTL. STUDS 24" O.C. O (/') OC N THERMOSTAT LOCATIONS TO BE REVIEWED BY OWNER PRIOR TO INSTALLATION. (IN REMODELS MATCH STUD SIZE TO ALLOW Z Q REUSE OF BLDG. STD. DOORS AND FRAMES) I — (.7 cc 12. TELECOMMUNICATION SYSTEM BY TENANT. �� 5/8" GYPSUM BOARD BOTH SIDES W H c9 C Op 13. PROVIDE ACOUSTIC GASKETS WHERE WALL INTERSECTS MULLIONS OR e...."-- Q � CENTER LINE OF STUD I- GLAZING. I W 0 cc co g Q U r I 3 1/2 BATT INSUL. CC 14. CONTRACTOR TO PROVIDE BUILDING STANDARD BLINDS AT ALL EXTERIOR ct a' an GLASS. • 4" RUBBER BASE TYP. F REVISION 15. CONTRACTOR TO PROVIDE AND INSTALL FIRE EXTINGUISHERS AS REQUIRED - ATTACH BOTTOM TRACK TO FLOOR WITH PER CODE. d� POWDER DRIVEN ANCHORS AT 12" O.C. 1. 2. �• 16. ALL DIMENSIONS ARE TO FACE OF SHEETROCK UNLESS OTHERWISE NOTED. I �li� FINISH FLOOR DATE: 11/30/10 2 TYPICAL WALL SECTION PERMIT SET A -2 SCALE 1" = 1' -0" A -2 ,...0 , #3082 �� g M TIN W HANSON CLACKAMA , OREGON i 13> 4' 0 F 0 ) PROJECT #10680 _I 6' J (1 , qA\ TENANT IMPROVEMENT WORK TO INCLUDE: I 0 O • CONSTRUCTION OF WALLS DOORS AND RECITES AS SHOWN OFFICE co CT) • ALL FINISHES ARE EXISTING TO REMAIN U.N.O. CD a • • FINISHES AT NEW CONSTRUCTION TO MATCH EXISTING. 3 11051 c Q 3 0 • ADJUSTMENT OF HVAC PER NEW WALLS • ADJUST FIRE SPRINKLERS PER NEW WALL i i d Q • 110V POWER DISTRIBUTION AS NEEDED PER TENANT Cp1LP Q a N f1 • SERVER WORK AS NOTED. Q N = �i ALL TELECOMMUNICATION, DATA, AND SECURITY SYSTEMS ARE - I I O O 0) O f) C'3 I BY TENANT. U A I • c� ° O (fl z W CP LP W OFFICE I Z cD m CO MM R 104 OPEN OFFICE - 01— L Lo 11031 2 \ ' ♦ 5 � / O /^ = X IL 41 i L T u_ 4 A -2 ��� =�I� SERVER � � • III U 11o61 _ • NEW \ACT FLOOR • ADD UNIT FOR .-� OPEN OFFICE DEDICATED AIR L' _ 101 WAREHOUSE z W MEI ..-:\ 2 U CO LP E V Ce A -2 OPEN OFFICE q_�- a � m al U — ?_, Q I 102 _ N I — — NI Q \:` CIR _� " �.J BREAK — W OMEN D O ME. N t- z Q W CI) cc Cm 100 WOCLp o ; 11071 11091 1 1101 a _ Q Q1 li n cr ` I j �n ` 1 l -`J I l 1� IIV� �� �� 1111 n n ^/ U m 0 5._0. r� w I— 0 0 cr Q cn //9 ¢ a T o 1 PARTITION & POWER PLAN a n a zEE) A -3 SCALE 1/8° = I - 0" REVISION I 1. I 2. DATE: 11/30/10 PERMIT SET • . A -3 . �- 41 I sr I . ,:, 0 wismam. > rr, m r i • I- ^ m q 0 c „ ><1 = n X Z .1 rillik v hal , Z / 1 I { 1 II _ I �\ • , • • N • l>.‘i • EBI 1>< . • 1. • IA >< i> >C - 1l ■I11MIME Ml >C >> -•. • • >4 IP lir ‘..- luillipll ix i im71 MI: eyes i:a::;= I• ii111a _ 1.-"H:iiiiIiiiiiiiii .. r ` • [X / 2:l: e3 ° °i ° °:!lE�rieeef e:3 • al r -7,: - - - = ' > " Z! 7 ii 13 v N 7L m > SPACE FOR: Martin W. Hanson, Architect C j RI < 15350 SW SEQUOIA PKWY #300 O y a (�j D _L o PROTECTION ONE PORTLAND OR 97224 z co PH (503) 624 -6300 n w m 5....%) Z FX (503) 624 -7755 - "s 2 " PACTRUST BUSINESS CENTER p Z �' 0 7312 SW DURHAM ROAD BUILDING H (pbc198) rn �� Z z 4- PORTLAND, OR 97224 00 A P AC T RUST PROPERTY 0 ��4 � y �