Plans 6L2oi2-0o255 2 3o SW / 7650 S. W. Beveland St. TM RIPPEY Tigard, Orcgon 97223 Phone: (503) 443 -3700 CONSULTING ENGINEERS Fax: (5031 443-3700 STRUCTURAL CALCULATIONS PROJECT: HOUSE OF BREAD — RTU LOCATION: TIGARD, OREGON CLIENT: PACIFIC CREST STRUCTURES DATE: MAY 11, 2012 PROJECT NUMBER: 12191 TABLE OF CONTENTS: ITEM SHEET NUMBER GENERAL NOTES N1 BUILDING PLAN SK1 SUPPORT FRAMING PLAN SK2 SECTRION THROUGH CURB SK3 CALCULATIONS Cl -05 g , \\ OREGON Z, I trVIE / • GENERAL STRUCTURAL NOTES CODE REQUIREMENTS: CONFORM TO THE 2009 INTERNATIONAL BUILDING CODE AS AMENDED BY THE 2010 OREGON STRUCTURAL SPECIALTY CODE. DESIGN CRITERIA: DESIGN WAS BASED ON THE STRENGTH AND DEFLECTION CRITERIA OF THE 2009 INTERNATIONAL BUILDING CODE. IN ADDITION TO THE DEAD LOADS, THE FOLLOWING LOADS WERE USED FOR DESIGN, WITH LIVE LOADS REDUCED PER IBC: ROOF LIVE LOAD: 25 PSF SNOW • BASIC WIND SPEED (3 -SEC GUST): 100 MPH WIND EXPOSURE: B SEISMIC SITE CLASS: D SDS: 0.719 ap: 2.5 Rp: 6.0 EXISTING CONDITIONS THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS, DIMENSIONS AND ELEVATIONS. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCIES FROM CONDITIONS SHOWN ON THE DRAWINGS PRIOR TO THE START OF THE WORK. TEMPORARY CONDITIONS THE CONTRACTOR SHALL BE RESPONSIBLE FOR STRUCTURAL STABILITY OF THE NEW AND EXISTING STRUCTURES AND WALLS DURING CONSTRUCTION. THE STRUCTURE SHOWN ON THE DRAWINGS HAS BEEN DESIGNED FOR STABILITY UNDER THE FINAL CONFIGURATION ONLY. DESIGN, FABRICATION, AND ERECTION SHALL BE IN ACCORDANCE WITH THE "AISC SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS ". WELDING SHALL CONFORM TO THE AWS CODES FOR ARC AND GAS WELDING IN BUILDING CONSTRUCTION AND SHALL BE 3/16" MINIMUM UNLESS OTHERWISE NOTED. WELDING SHALL BE BY AWS CERTIFIED WELDERS. PREQUALIFIED WELDING PROCEDURES ARE TO BE USED, UNLESS AWS QUALIFICATION IS SUBMITTED TO THE ENGINEER PRIOR TO FABRICATION. CARPENTRY: SAWN LUMBER DESIGN IS BASED ON THE NATIONAL DESIGN SPECIFICATION, LATEST EDITION. SAWN LUMBER SIIALL CONFORM TO WEST COAST LUMBER INSPECTION BUREAU OR WESTERN WOOD PRODUCTS ASSOCIATION GRADING RULES. ALL LUMBER NOT SPECIFICALLY NOTED TO BE D.F. #2 OR BETTER. ALL WOOD IN PERMANENT CONTACT WITH CONCRETE OR CMU SHALL BE PRESSURE TREATED UNLESS AN APPROVED BARRIER IS PROVIDED. FRAMING ACCESSORIES AND STRUCTURAL FASTENERS SHALL BE MANUFACTURED BY SIMPSON STRONG -TIE COMPANY (OR ENGINEER APPROVED EQUAL) AND OF THE SIZE AND TYPE SHOWN ON THE DRAWINGS AND ATTACHED PER MANUFACTURER'S REQUIREMENTS AND RECOMMENDATIONS UNLESS NOTED OTHERWISE. HANGERS NOT SHOWN SHALL BE SIMPSON HU OF SIZE RECOMMENDED FOR MEMBER. ALL FRAMING NAILS SHALL BE COMMON NAILS. NO BOX _ NAILS ALLOWED. FASTENERS AND ACCESSORIES IN CONTACT WITH PRESERVATIVE TREATED WOOD MUST BE HOT DIPPED GALVANIZED OR HAVE ZMAX COATING. MECHANICAL: THE CONTRACTOR SHALL COORDINATE SEISMIC RESTRAINTS OF ELECTRICAL EQUIPMENT, MECHANICAL, PLUMBING, FIRE SPRINKLER, MACHINERY, AND ASSOCIATED PIPING WITH THE STRUCTURE. ANY CONNECTIONS TO STRUCTURE NOT CONFORMING TO SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION (SMACNA), OR SPECIFICALLY DETAILED ON THE MECHANICAL ENGINEER'S DRAWINGS, SHALL BE DESIGNED IN ACCORDANCE OF THESE GENERAL NOTES, BY AN ENGINEER REGISTERED IN THE STATE OF OREGON, AND SHALL BE SUBMITTED TO THE ENGINEER PRIOR TO FABRICATION. FLASHING AND WATERPROOFING; ALL FLASHING AND WATERPROOFING SHALL BE BY OTHERS UNLESS NOTED OTHERWISE ON THE PLANS. • TM RIPPEY 1 -- 139 ' RI • Consulting Engineers By: � t aC Date: 7650 SW Beveland Street _ _— Chic By: Date: Suite 100 Tigard, Oregon 97223 Job #: I "1 Phone: (503) 443 -3900 Sheet: N 1 _ Of: 'I e i u t f f Z' k f . 1 a f L ss -# s 3 s z € f 4 . :, ,i's > Sa � .:'� ''' E E " s „ : 3f,i s s . / . t i t,2 3 N i, :;` c i ;.yz 1 .. . f fi k I l i S y a . 4 Y z z � ' ���. • a is #Y•,s '%1:: kvle R 4 A s � �: ;`ri. y . s : �5. ,Y P >F iS: • E ° # y.r i / Y /4�5 t - ) k k. �4 1 �t s 1 r aA '•y y , s: t � ;� y?:s nap, i�h�•: ri<� ! .# ti. z - . � \.;,,,.-,-, � � n , � .. .1 , •lh .z:% .'si a ;..i i x s ` r li{ ' � tt , i f 4 2 t ' x 'S uTw; )I s T S�c" -- •�^ ....u,t r ' ' l r' ' ' t,. G k 6 C .. ( , •.A> � +4A S I� i 4 % � f d �i3 E -S � 4E �': ma t� YNf Z A S k i- 3 v : ' i =11Y':, F' s. ? ' �N 3,) �# .a+� s t . k ' ` t ,' $ ' ,, , _ -' � j f use .� y"� l �•` ' 4 ,k . ': 3 f i ` C t ' f� � t � �� t • t k d x '.."ii r ,04,.. z +� � ' N. ','' la f i 511 ..... N 1.,,,� .,y r� .(. �tRa.A of Wor' S all- B . P . ta StAPPo ' /SI F1'4bM�1u f� i l l I I t4 IL-b i ti p- Pi.. • ta/ �� TM RIPPEY U �^ p , o a {, Consulting Engineers v, • �.' 1 �\ By: [ _ Date: 7650 SW Beveland Street Clilc By: Date: Suite 100 Tigard, Or egon 97223 Job #: yy.� 7' H Phone: (503) 443 -3900 Sheet: 3 ) I Of: 3 ( I 7 rbAe - Fr.S .Dri..st FOP— NUCKTto ALU,.N %ANC OtNyt' P.00.F OVER . MUM. LOPS Wrflito 5'-b" FROG M c (6)6t, aFA. PR(o '/ ax RAT (.e,) GI-5, �s 4ko►to k v..k) rJaW (NaccmG OunucvG ash Er R MVA1 NI- l.Cx- i•riM4 `N\'11}V.1 VD OF Grt. GOWN AND {3uiriM — CIA"‘ kg-VA , OF-200F OSCic t.'_6 I/ / - — -. / A A — - Z .1,#,Arf# A / A/I — ' I r f .r 7 r V , Fry , i pjj N vAi C - ro ?kl 1 , , JT = loo3 • 1 r I -- (E) ?a„ TnCz' " oi j a / ..- - ..�f�ir:�r r /� 4 7 �i A Jr •, ; % /� //: -- i / , 4 1 O t Z � 6 SA Po2'f F2s>,Ak ,.1 - C, 1L. ---► lEAK TM RIPPEY !' 0W -45�.- OF 1ST - 1 ° \ BY k(5iVc_ DATE CONSULTING ENGINEERS CHK BY DATE 7650 S.W. Beveland St, Suite 100 JOB NO I2 1 9 Tigard, Oregon 97223 SHEET 5/C OF 3 Phone (503) 443 -3900 III TRUSS WEB TRANSFER BLOCK NOTCH LOCATION - DETAIL 'A' NEW RTU —N • NEW RTU CURB TO BE 2x4o DF. M2 CENTERED ON NEW FRAMING MEMBER (3) SIMPSON SDS 1 4 x 3" (NW ILI" TALL , PI 6/1.) SCREWS TO VERTICAL SIMPSON SDS I ns x 3" BLOCKING, EQ. SPACING SCREWS SPACED m1=0" O/C TYP. x —17 T' x r —1 x— x 1 � , �f�,a i • • 10 SCP.E • I -pt A(ZO.ANA PFIt(ThAois2 • (a" PFIJET•(L4iio,' 7JTo I.0\1m). yxy bF NEW 2x LOAD TRANSFER NEW FRAMING MEMBER PANEL POINT, A BLOCKS TO BE CONSTR. WI SIMPSON 'LUS' FACE TYP. g PANEL POINTS, NOTCH MOUNT HANGERS WI OVER EXIST. TRUSS WEB I0d NAILS (D0 0.I48 L=1 /2 ") AT UNIT EDGES PARALLEL vJZ41-1 s75 ax 0 SECT IO ��,- I✓l OU DJc TMRGEN- RTU - SCALE: NTS • .1EA? TM RJPPEY 1 6w-d Cr t312- — P BY DATE C ONSULTING ENGINEERS T— CHK BY DATE 7650 SW Beveland, Suite 100 Tigard, Oregon 97223 JOB NO E i 9 I Phone: (503) 443 -3900 Fax: (503) 443 -3700 SHEET . K . r OF 3 l ( R7V\ W't = o il;- ' - Ca � Gd Z ".0 •, 0 / � , " f YP cuoz a 4v i : / tJ 3 # `' a RZI\ pt■ = $8 x 60 W x HI ,I 1+ 0/64 evaa DIM 7 S -•- TZcx�F 01- art X11 (Drzsl�ti Lo? I' ti _ n ��, P�oFt ►�� 3 r'S - 3/ 4 ''5 1yb1c1Fr Ka. c Z, Z`S?SF v k./.cS t 0!- = o , S 1$F Lldti'( /Ame-N I. s QSF 1 i sysi., @1t- , = 1tS p.SF tio" "Mt - )(<- F5) 12 1 Zs f'SF. Pc Mhb tr.ava rF St_ - 2S" Ps G u23 nest eJ V n a l' t-1 , -.16._ LO NC> % -- x ico = 60 2 60a11'/g;5' 90 in R1'v■ SA- r 2s r n 88 "x 60" _ 9 17 I'-tW = NsoW z 4 5 5 + k, S / - 70 j'L1= M - L93 + .70) %I-A.7- x 7, 61 .1- Pic ^ # b fe D lyS, Iz z41 ,r � ,w �siz `-t k`-1 r #2 I yc1h I AA% livii\ TM RIPPEY IA 0,m4"...- o\'- 1I1 -\'FP4::4 - cal y&, BY \ \\ DATE CONSULTING ENGINEERS CHK BY DATE 7650 S.W. Beveland St, Suite 100 JOB NO \ r i- \ I Tigard, Oregon 97223 Phone (503) 443 -3900 SHEET C I OF C t'ftzLh CR- T71- A- A nA • VUO @S`T G A - edg - t oN(3% 14 12 TO M► i� a. �v' so lb1 �s X l Cpb ' 6ol Y2 .x 602 1\ � tinnt�� ti or' �v�fl o ,,) M.) Vz L424 (7 (.2 La ( rZ) "ae..T S br_s‘6, -zc1:1. S0;z- itODat ca.m !.te a PT LC»eL� FoR- NW -4 ht. ' 3c0 - ( ) TEL no\ S 5 01.c G 1+ r c-k- C r) Co t.-a G S /M x Z ? ll G t. 3 /Z = 2ex.2c 7 F2 � Z4 ca rs t, S1� 1.1 s- 2r, F ZGS i pAt v. °v\^`l- 1coo3'4/6 S = IS'�I (FT �Q�.. _ 2-e) l2, 2s Fs?.. - 3 H S c=1._t- ?,V-(1 — 2Fi x 2S PSF '7co PL- ( JRTy \ b V WDt tY— (1L, tjLi V i_ TM RIPPEY tfO\AW 1 ,-17t; FcC) R S BY 1 Cw6- DATE CONSULTING ENGINEERS CHK BY DATE 7650 S.W. Beveland St, Suite 100 JOB No Tigard, Oregon 97223 ( Phone (503) 443 -3900 SHEET of Title Block Line 1 • Title : Job # You can changes this area Dsgnr: using the "Settings" menu item Project Desc.: _ and then using the "Printing & Project Notes : Title Block" selection. Title Block Line 6 Printed: I I MAY 2012, 7•55AM • ',:::.iii.,,,, , < , , :.. . .sti' `';,v<F : t `•< 7 1,k.) :. ;120P' 4112191: ftiiA 9ke RTuwrp u,ipmi9t.o. w` %'Y ` �` • ;,(S'� A >�� ;c ;., ,.: ti'{%�' C`;i. . <c,,<•,'`.4: a:' �:'` ,p .rot ..�.. 7 RAtLcs ,,., .< ,,, y a y . ' ,, : .r:.., ,Z <,.: , \'.:, `' 12 ' :. 11.51 e'1` 1U od Be���rm��'�. "s >; > \ rf ; - < <'r,. „F.< ;,,� �,� .�;;;:.,�.< . - , ? ; aENERCALCriNC r :,1983.201f&iild:6 . V .6:11.5. Ltc., #; KW;Ofi002662 ; , ! ., ..:�. .:... :;,, .:.:'.::.. . ;., ,:. ' „:i Licensee 7M RIPFEY CQNSULTING'ENGINEEF:S< Description : 6 3/4 x 27 GLB Material Properties Calculations per NDS 2006, IBC 2009, CBC 2010, ASCE 7 -06 Analysis Method : Allowable Stress Design Fb - Tension 2,400.0 psi E : Modulus of Elasticity Load Combination 2009 IBC & ASCE 7 -05 • Fb - Compr 1,850.0 psi Ebend - xx 1, 800.0 ksi Fc - Prll 1,650.0 psi Eminbend - xx 930.0 ksi Wood Species : DF /DF Fc - Perp 650.0 psi Ebend - yy 1,600.0ksi Wood Grade :24F - V4 Fv 265.0 psi Eminbend - yy 830.0 ksi Ft 1,100.0psi Density 32.210pcf Beam Bracing : Beam is Fully Braced against lateral- torsion buckling D(0.154) ,( "1.v1`1) + * $ $ + D(0.343) S(0.7) + * $ + + .. .. :.... ... . .... .. .. :...... »:�., ,..; ,,, - . ,�... •., .::.,.; . : .,� �., >• , Yi ' t e > :�. ... :a:s: •.,. .., �, `"`o"`:� •c,..'' <ci rzi',•• ::;r:;'�?A�\x�.: "rr ;a, :�` , .,,;. c.� :« i'i�'',SA :`)'^1•a:� . �.'%, .Y.y „ \'2T �,.:cr.: `�'''SY: �+�i,,`. „s \... >A .<,,\ h , ;:rsK ��x; c€, �';>'. v�\. \ f<," \ �,xiip.,.;yRL'`� \: ?' ,,x. . ,. ` xfir�, . ., � . . ..� , ,,; ,',,, a imi C , Y : , . , . >.f...: :4 ' \ „ > :?`:, : ;.,, ; , „ >,\`' s ' ';e •T\,., f :. > }. . �T,,., s �"� „R•::. ^': xya, z >�.:•;•+ ,a �.� ,� ::_c: k `�. , , . »x.,, w ,.: � : � re,. z ,'€ �. � , i::i. xv X'.• i, r, > : ',,i :X:.:' ��'' \vim �� Zn .<... .3°<�`?�•',l^ �� -� ...♦cw, ice.. 3; .... ": �.,,r ,C „�;'_ „ <. , ;EA ,..„'. r ,3�. w ': ,: <: : :.*:.:. 3,s;r, : ,•.@ '? az Si u ♦,..:a > a..C >.: � -�., $ .., e: :•x�;�t� s3:;:t `�Fa :,+��, his r � ,. �- ,�:� , »e�fi.�si � .\ .`i: }cr„•`s�, :� »Ci °..� ^i.. >`Y \. �;ii `, \1:: .,;1��. v -., �•x ::',,; ;.,,�., y'C, ,.3, �• 2, , ',: •a1� flit\ , d�.3.�: . �i :��.; ,,� l.\ ,�:..`4' • � . , '7:�: ; ��';:�`':�`:: :�.�: -„ 3, ,:: ,;. 'x @.,o; ; >, : si:�.... :• >.�.,. �,- �;;:.. .i3..j'. \ �� `.� '�.k:,,.v�;ic, i.'. �g,... :':'Y" - '+. , . �. <. •,�'� ,•r ,. .�3.�•� :•..:�.s?xo�,,�.. \.L U4 ��., tc. -. `x,x!i .W� r �• ,�.. �..,.�,;. }�' q� -.. n i», Ng fi'€iri;^•'1.\'''. a ,,, xs,F#. 0, ,, ' �. - 44- ;,y j},v .Y;, 041;,x:...44i..,.,f., .• � >� 3..>.. »,. \� „�, ..L. •�.,,� C..��i 'Nisi. ,��. �t F .. .. ; - a .. . =L ``\ r� % ::�el,y� Ar, \<f: :Y::�b �r <s ',i"3i�.2. .e: \�:::: ?� ? »�� , \. • t:� :: �:, :,*,� •ss'! r ..i,, . ��,�� , ..>,,.�,t� � . �-..., '> `� :...�;� ,. y' ♦1�,�� ,?:� : � Z � � :3:.: `;� .•� x.:. >,Y . T .?E�:.x:�.:' :,., � ;izx. _E� \ ;l�t e�'a.�'�c::'c i�•r5." .c �` �` ��: � ,�;\�. °:��.�; Z ', y kr,<.; Y�l� �, "S:� ��€111 �� ., �..,. •s.$c ><:i \Z`r:. ..;:�•. c.�.�.axx.� .; xK q`v ,�lY�i �,�r.. �:�. u, < jZt `ji` , �a�.. , .. i » �.: ^, '.e• � ,� "`• �� • • • o ' 6.75x2 2 Span = 28.917 ft S I loads entered. Load Factors will be applied for calculations. .:Applied`Loads:' •• ,: • . . , Service oa s e i a t Beam self weight calculated and added to loads - Uniform Load : D = 0.01225, S = 0.0250 ksf, Tributary Width = 28.0 ft Uniform Load : D = 0.1540 k/ft, Extent = 0.0 - -» 3.250 ft, Tributary Width =1.0 ft :.: DESVI SU&1I 9.RY4_:YV;-; - -;, . ::_ H - . Maximum Bending Stress Ratio = 0.798 1 Maximum Shear Stress Ratio = 0.418: 1 Section used for this span 6.75x27 Section used for this span 6.75x27 fb : Actual = 1,663.41 psi fv : Actual = 110.76 psi FB : Allowable = 2,085.16psi Fv : Allowable = 265.00 psi Load Combination +D +S +H Load Combination +D +S +H Location of maximum on span = 14.458ft Location of maximum on span = 0.000 ft Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1 Maximum Deflection Max Downward L +Lr +S Deflection 0.557 in Ratio = 622 Max Upward L +Lr +S Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.866 in Ratio = 400 Max Upward Total Deflection 0.000 in Ratio = 0 <180 • • :, Maxini i o & f o lo • Combinat i on s; Load Combination Max Stress Ratios Summary of Moment Values Summary of Shear Values Segment Length Span # M V C d C FN C r C m C t Mactual lb- design Fb -allow Vaclual fv- design Fv -allow +D 0.869 1.000 1.000 1.000 Length = 28.917 ft 1 0.284 0.151 1.000 0.869 1.000 1.000 1.000 40 52 592.87 2,085.16 4.85 39.96 265.00 +D +S +H 0.869 1.000 1.000 1.000 Length = 28.917 ft 1 0.798 0.418 1.000 0.869 1.000 1.000 1.000 113.68 1,663.41 2,08516 13.46 110.76 265.00 +D +0.750L +0.7505 +H 0.869 1.000 1.000 1.000 Length = 28.917 ft 1 0.669 0.351 1.000 0.869 1.000 1.000 1.000 95.39 1,395.78 2,085.16 11.31 9306 265.00 +D+0.750L +0.750S+0.750W +H 0.869 1.000 1.000 1.000 Length = 28.917 ft 1 0.669 0.351 1.000 0.869 1.000 1.000 1.000 95 39 1,395.78 2,08516 11.31 93.06 265 00 +D+0.750L+0.7505+0.5250E +H 0.869 1.000 1.000 1.000 Length = 28.917 ft 1 0.669 0.351 1.000 0.869 1.000 1.000 1.000 95 39 1,395.78 2,085.16 11.31 93.06 265.00 L3 Title Block Line 1 Title : Job # You can changes this area Dsgnr: - using the "Settings" menu item Project Desc.: and then using the "Printing & Project Notes: Title Block" selection. • Title Block Line 6 Piintod: 11 MAY 2012, 7 55AM earn Sl•<' 1 . 6 M 91 Alpu,_.,s0, 9 , 1 # 1) 40 ,( 91M ,R,USTUNWPAI;d92 , - M Z% :,KV11-06002662• • - . „ • ' , Licensee M I•P V CO SL1L I 1 Description : 6 3/4 x 27 GLB ...Overall MaximIim thifactoreil toads' Load Combination Span Max. Deft Location in Span Load Combination Max. '+' Deft Location in Span D+S 1 0.8661 14.458 0.0000 0.000 • • . . V. " -Vertical :Reactions.-Unfactored.. s. ; - Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 16.142 15.698 D Only 6.021 5.577 S Only . 10.121 10.121 D+S 16.142 15 698 • • • • CA1 Wind and Seismic Loads on Mechanical Unit '. Worksheet Calculates the wind and seismic forces for a rooftop mounted mechanical unit based on the ASCE 7 -05 or the 1998 UBC OSSC, using the more conservative value. Hold down forces are calculated based on 0.6D + (W or 0.7E) load cases. Wind and Seismic Loads on Mechanical Unit Windspeed := 100mph Exposure := "B" Fastest_Mile := "no" (Windspeed is a fastest mile value ?) Seismic Parameters S := 0.719 a • = 2.5 R • = 6 IE := 1.0 Building Dimensions Category := "H" Roof Elevation := 20ft Mechanical Unit Dimensions Displacement :_ "Mech Unit" • Weight := 10031b ' UnitHeight := 41in • Width := 60in Length := 88in Curb := 14in GCS..,-, SUMMARY Method Used = "ASCE 7 -05 - Analytical Procedure 6.5" D = 1.003 x 10 lb Displacement = "Mech Unit" 1 I saa-�.vus ib ‹--- E ASD = 252 lb h seismic = 2.875 fl .. 0 / W = 600 lb 1111 x I (, k (�, '1 2- ,N7 ifikcl2-f $✓ O. 6 4 2 ; = 14 .0,f3 -al I tA, , . h 2 ft T x. 4.67fl I T 7 lb Wind = Wind = Notes: T seismic = -146 lb 1. Positive sign convention shown. Negative values indicate opposite direction 2. X equals the width of the unit minus 4" NU , iP-1 r 4MK cr. 580J • GAS HEAT/ELECTRIC COOLING PACKAGED ROOFTOP • 3 TO 12.5 NOMINAL TONS bryant . a Product Data LEGACY TM LINE .., , •; • - : _ ___ . __._ ___________-___ _. _• ___-___._ - ___ __ _ ... =__ ; ryan , , • z..-_=_ - - - -.-__ : _- . 1 LEGACY smoloreziol •--- :7_7_7_ -- - -_-.: i ._ - -- :.-_-.7_-_ ‘.,-_-,,_--_- :::::-_-_ •=_-- : ----7_-__- ---:.--_-_ 1 -.....-.-- ,•,..„=-._ ::_.--• , ... ! . ., 1 • •---- ::-._=--__ ;.•-,-__.---:. ::_-_-__:: ; .. • ., .•-•-. -..-:•_-=.- =---------: ; • ----:...- ---. — - .- , .: -- : -_ :•.-:, ..- ._--] ----:-.•:-_- ----- • .::::::-_.: ..:- -.:._--- --.:_-_-.-: • ; . -, . ; :_-_-::::: •..-__-_:.-__ ---:---, -.•:•_- — - • • .,I • . - I - -..• ' ,,- ------------- -----; - -----1 . : - 1' , 1 : I pi..ion. _. ..... ..._ ..__ • : - . - 1104____----- ' ...__••• .:. _:-- . - WON ____---------_ ._ Pk• 7 . . A 1 k 0 - .. ___._::______---- C08515 (Unit shown with optional louvered hail guard.) . r • ASHRIIE Purom • ENERGY STAR ine onvIlcommEngy sound oshiguare COMPLIANT PARTNER ... • FEATURES AND BENEFITS • Single cooling stage models are available from 3 - 10 ton. • Two cooling stage models are available from 7.5 - 12.5 ton. • • SEER up to 13.0. • EER's up to 11.1. • IEER's up to 11.8. • Up to 28% lighter than similar industry units. Lighter rooftops make easier replacement jobs. • Utility connections are the same because 3 -12.5 ton units fit on existing Bryant rooftop curbs. This saves time and money on replacement jobs. • Standardized components and layout. Standardized components and controls make service and stocking parts easier. • Scroll compressors on all units. This makes service, stocking parts, replacement, and trouble- shooting easier. • Field convertible airflow (3 -12.5 ton). Being able to convert a unit from vertical airflow to horizontal makes it easy to c overcome job site complications. co • Easy- adjust, belt -drive motor available. Bryant provides a factory solution for most points in the fan performance table. There's no need for field- supplied drives or motors. • Provisions for bottom or side condensate drain. • Capable of thru- the -base or thru- the -curb gas -line routing. • Single -point gas / electrical connection. • Sloped, composite drain pan. Sloped, composite drain pan sheds water; and won't rust. • Standardized controls & control box layout. Standardized components & controls make stocking parts & service easier. • Tool -less filter access door. • Clean, easy to use control box. • Color -coded wiring. • Large, laminated wiring and power wiring drawings which are affixed to unit make troubleshooting easy. • Single, central terminal board for test and wiring connections. • Fast - access, handled, panels for easy access on normally accessed service panels. • "No- strip" screw system guides screws into the panel & captures them tightly without stripping the screw, the panel, or the unit. • Exclusive, newly- design indoor refrigerant header for easier maintenance and replacement. • Mechanical cooling (115 °F to 25 °F or 46 °C to -4 °C) on Direct Digital Controller (DDC) with Winter Start Kit (RTU -MP controller). • Mechanical cooling (115 °F to 25 °F or 46 °C to -4 °C) on Electro- Mechanical (E /M) models, with Winter Start Kit. • High efficiency, gas heat with induced -draft flue exhaust design (3 -12.5 tons). • Induce draft motor ensures no flue gas can escape into the indoor air stream. • Bryant designed naturally draining heat exchanger, unlike positive pressure heat exchangers, do not need to be periodically, manually drained. This saves labor and maintenance expense. • 2" (51mm) disposable filters on all units. • Refrigerant filter -drier on each circuit. • High and low pressure switches. Added reliability with high pressure switch and low pressure switch. • Many factory - installed options ranging from air management economizers, 2 position dampers, plus convenience outlets, disconnect switch and smoke detectors. • Standard Warranty: 10 yr. aluminized heat exchanger, 5 yr. compressor, 3 yr. NOVATION' condenser coil, 1 yr. parts. • Factory- installed Perfect Humidity dehumidification system on 3 -6 ton models, includes MotorMaster I controller for cooling operation down to -20 °F (- 29 °C). 3 MODEL NUMBER NOMENCLATURE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 5 8 0 J E 0 6 A 0 7 2 A 1 A 0 A A • Unit Type Packaging 580J = Cooling /Gas Heat RTU A = Standard Legacy Series w /Puron Refrigerant B = LTL Voltage Factory Installed Options E = 460 -3 -60 OA = None J = 208/230 -1- 60 P = 208/230 -3 -60 Intake /Exhaust Options T = 575 -3 -60 A = None B = Temp econo w/ baro relief Cooling Tons E = Temp econo w/ baro relief & CO2 03 04 = 3 Ton H = Enthalpy econo w/ baro relief 05 = 4 Ton L = Enthalpy econo w/ baro relief & CO2 06 = 5 Ton Q = Motorized 2 pos damper 07 = 6 Ton 08 = 7.5 Ton Indoor Fan Options 09 = 8 5 Ton 1 = Standard static option 12 = 10 Ton 2 = Medium static option 14 = 12.5 Ton 3 = High static option Refrig. System /Gas Heat Options Coil Options (outdoor- indoor -hail guard) A = 1 -Stage Cooling /Nat gas heat A = Al /Cu -Al /Cu B = 1 -Stage Cooling /Low NO heat B = Precoat Al /Cu - Al /Cu C = 1 -Stage CoolingSS HX C = E -coat Al /Cu - Al /Cu D = 2 -Stage Cooling 08 -14 D = E -coat Al /Cu - E -coat Al /Cu F = 2 -Stage Cooling /SS HX E = Cu /Cu - Al /Cu G = 1 -Stage Cooling /AI HX w /Perfect Humidity 04 -07 F = Cu /Cu - Cu /Cu H = 1 -Stage Cooling /Low NO w /Perfect Humidity 04 -07 M = Al /Cu - Al /Cu - Louvered Hail guards J = 1 -Stage Cooling /SS HX w /Perfect Humidity 04 -07 N = Precoat Al /Cu - Al /Cu - Louvered Hail Guards P = E coat Al /Cu - Al /Cu - Louvered Hail Guards Heat Level Q = E coat Al /Cu - E coat Al /Cu - Louvered Hail Guards Standard /Stainless Steel R = Cu /Cu - Al /Cu - Louvered Hail Guards 072 = 72,000 S = Cu /Cu - Cu /Cu - Louvered Hail Guards 115 = 115,000 Coil Options AI /AI Novation 2 -stage Cooling only 125 = 125,000 (outdoor- indoor -hail guard) 150 = 150,000 G = Al /AI - Al/ Cu 180 = 180,000 H = AI /AI - Cu /Cu 224 = 224,000 J = AI /AI - E coat Al /Cu 250 = 250,000 K = E coat Al /AI - Al/ Cu Low NO L = E coat Al /AI - E coat Al /Cu 060 = 60,000 T = AI /AI - Al /Cu - Louvered Hail Guards 090 = 90,000 U = Al /AI - Cu/ Cu, Louvered Hail Guards 120 = 120,000 V = Al /AI - E coat Al /Cu, Louvered Hail Guards W = E coat Al /AI - Al/ Cu, Louvered Hail Guards X = E coat AI /AI - E coat Al /Cu, Louvered Hail Guards 4 TABLE 2 - AHRI COOLING RATING TABLE 1 -STAGE COOLING • NOM. NET UNIT COOLING CAPACITY COOLING TOTAL SEER EER IEER - STAGES (TONS) CAPACITY POWER (kW) (MBH) 04A 1 3 34.6 3.1 13.00 11.00 N/A . 05A 1 4 45.0 4.0 13.00 11.00 N/A 06A 1 5 59.0 5.5 13.00 10.75 N/A 07A 1 6 70.0 6.4 N/A 11.00 11.2 08A 1 7.5 88.0 8.0 N/A. 11.00 11.2 09A 1 8.5 97.0 8.8 N/A 11.00 11.2 12A 1 10 117.0 10.6 N/A 11.00 11.2 TABLE 3 - AHRI COOLING RATING TABLE 2 -STAGE COOLING NOM. NET UNIT COOLING CAPACITY COOLING TOTAL SEER EER IEER STAGES (TONS) CAPACITY POWER (kW) 0 (MBH) 00 08D 2 7.5 83.0 7.5 N/A 11.00 • 11.7 in 09D 2 8.5 99.0 9.0 N/A 11.00 11.7 . 12D 2 10 114.0 10.3 N/A 11.10 11.8 14D 2 12 5 140.0 12.9 N/A 10.80 11.0 LEGEND NOTES: AHRI - Air Conditioning, Heating and Refrigeration 1. Tested in accordance with AHRI Standard 210/240 -06 Institute Test Standard or 340/360 -07, as appropriate. ASHRAE - American Society of Heating, Refrigerating 2. Ratings are based on: and Air Conditioning, Inc. Cooling Standard: 80 °F (27 °C) db, 67 °F (19 °C) wb EER - Energy Efficiency Ratio indoor air temp and 95 °F (35 °C) db outdoor air temp. IEER - Integrated Energy Efficiency Ratio IEER Standard: A measure that expresses cooling SEER - Seasonal Energy Efficiency Ratio part-load EER efficiency for commercial unitary air - conditioning and heat pump equipment on the basis of weighted operation at various load capacities. UL ASHRAM 3. All 580J units comply with ASHRAE 90.1 Energy C O us ; , `". Standard for minimum SEER and EER requirements. COMPLIANT - ram CERTIFIED ..,w..na.enmr.mc C 1 Use of the AHRI Certified TM -� Mark indicates a manufacturer's participation in the program For ENERGY STAR verification of certification for individual products, go to PARTNER www ahridirectory org 8 • TABLE 4 — HEATING RATING TABLE - NATURAL GAS & PROPANE AL/SS HEAT EXCHANGER THERMAL ' TEMP RISE AFUE Units Gas Heat INPUT / OUTPUT INPUT / OUTPUT (DEG F EFFICIENCY ( � o STAGE 1 (MBH) STAGE 2 (MBH) ) (o) o ) LOW - 72 / 59 25 - 55 82% 81% 04 MED - 115 / 93 55 - 85 80% 80% a HIGH - - - - - a a LOW - 72 / 59 25 - 55 82% 81% d 05 MED - 115 / 93 35 - 65 81% 80% c HIGH - 150 / 120 50 - 80 80% 80% Cl) LOW - 72 / 59 20 - 55 82% 81% 06 MED - 115 / 93 30 - 65 81% 80% HIGH - 150 / 120 40 - 80 80% 80% LOW - 72 / 59 25 - 55 82% N/A 04 MED 82 / 66 115 / 93 55 - 85 80% N/A HIGH - - - - - LOW - 72 / 59 25 - 55 82% N/A o 05 MED - 115 / 93 35 - 65 81% N/A co HIGH 120 / 96 150 / 120 50 - 80 80% N/A LOW - 72 / 59 20 - 55 82% N/A 06 MED - 115 / 93 30 - 65 81% N/A HIGH 120 / 96 150 / 120 40 - 80 80% N/A LOW - 72 / 59 15 - 55 82% N/A y 07 MED - 115 /93 25 -65 81% N/A a a HIGH 120 / 96 150 / 120 35 - 80 80% N/A E LOW - 125 / 103 20 - 50 82% N/A H 08 MED 120 / 98 180 / 148 35 - 65 82% N/A HIGH 180 / 147 224 / 184 45 - 75 82% N/A LOW - 125 / 103 20 - 50 82% N/A 09 MED 120 / 98 180 / 148 30 - 65 82% N/A HIGH 180 / 147 224 / 184 40 - 75 82% N/A LOW 120 / 98 180 / 148 25 - 65 82% N/A 12 MED 180 / 147 224 / 184 30 - 65 82% N/A HIGH 200 / 160 250 / 205 35 - 70 80% N/A LOW 120 / 98 180 / 148 20 - 65 82% N/A 14 MED 180 / 147 224 / 184 25 - 65 82% N/A HIGH 200 / 160 250 / 205 25 - 70 80% N/A NOTES: Heat ratings are for natural gas heat exchangers operated at or below 2000 ft (610 m). For information on Propane or alti- tudes above 2000 ft (610 m), see the Application Data section of this book. Accessory Propane /High Altitude kits are also available. In the USA the input rating for altitudes above 2000 ft (610m) must be derated by 4% for each 1000 ft (305 m) above sea level. In Canada, the input rating must be derated by 10% for altitudes of 2000 ft (610 m) to 4500 ft (1372 m) above sea level. 9 TABLE 10 — PHYSICAL DATA (COOLING) 7.5 - 8.5 TONS 580J *08A 580J *08D 580J *09A I 580J *09D Refrigeration System # Circuits / # Comp. / Type 1 / 1 / Scroll 2 / 2 / Scroll 1 / 1 / Scroll 2 / 2 / Scroll RTPF models R -410a charge A/B (lbs - oz) 13 - 12 8 - 5 / 8 - 2 15 - 4 10 - 5 / 10 - 12 Novation R -410a charge A/B (lbs - oz) - 4 - 6 / 4 - 6 - - Metering device Acutrol Acutrol Acutrol Acutrol High - press. Trip / Reset (psig) 630 / 505 630 / 505 630 / 505 630 / 505 Low - press. Trip / Reset (psig) 54 / 117 54 / 117 54 / 117 54 / 117 Evap. Coil Material - Tube / Fin Cu /AI Cu /AI Cu /AI Cu /AI Coil type 3/8" RTPF 3/8" RTPF 3/8" RTPF 3/8" RTPF Rows /FPI 3/15 3/15 3/15 3/15 . total face area (ft2) 8.9 8.9 11.1 11.1 Condensate drain conn. size 3/4" 3/4" 3/4" 3/4" Evap. fan and motor Motor Qty / Drive type 1 / Belt 1 / Belt . 1 / Belt 1 / Belt `° Max BHP 1.7 1.7 1.7 1.7 0 a m RPM range 489- 747 489 -747 518 -733 518 -733 co v a. motor frame size 56 56 56 56 v c-) Fan Qty / Type 1 / Centrifugal 1 / Centrifugal 1 / Centrifugal 1 / Centrifugal u) Fan Diameter (in) 15 x 15 15 x 15 15 x 15 15 x 15 0 o Motor Qty / Drive type 1 / Belt 1 / Belt 1 / Belt 1 / Belt id Max BHP 2 9 2.9 2.4 2 4 m U) m RPM range 733 -949 733 -949 690 -936 690 -936 a. motor frame size 56 56 56 56 °' Fan Qty / Type 1 / Centrifugal 1 / Centrifugal 1 / Centrifugal 1 / Centrifugal Fan Diameter (in) 15 x 15 15 x 15 15 x 15 15 x 15 Motor Qty / Drive type 1 / Belt 1 / Belt 1 / Belt 1 / Belt Max BHP 4.7 4.7 3.7 3.7 11 0 RPM range 909 -1102 909 -1102 838 -1084 838 -1084 .c . motor frame size 145TY 145TY 56 56 En o_ z c) Fan Qty / Type 1 / Centrifugal 1 / Centrifugal 1 / Centrifugal 1 / Centrifugal Fan Diameter (in) 15 x 15 15 x 15 15 x 15 15 x 15 RTPF Cond. Coil Material - Tube / Fin Cu /Al Cu / AI Cu / AI Cu / AI Coil type 3/8" RTPF 3/8" RTPF 3/8" RTPF 3/8" RTPF Rows /FPI 2/17 2/17 2/17 2/17 Total Face Area (ft 20 5 20 5 21 4 25.1 Novation Cond. Coil Material - Tube / Fin - Al / Al - - Coil type - Novation'" - - Rows / FPI - 1 / 20 - - Total Face Area (ft - 20.5 - - Cond. fan / motor Qty / Motor drive type 2 / direct 2 / direct 2 / direct 2 / direct Motor HP / RPM 1/4 / 1100 1/4 / 1100 1/4 / 1100 1/4 / 1100 Fan diameter (in) 22 22 22 22 Filters RA Filter # /size(in) 4/16x20x2 4/16x20x2 4/20x20x2 4/20x20x2 OA inlet screen # /size(in) 1 /20x24x1 1/20 x24x1 1 /20x24x1 1 /20x24x1 14 TABLE 12 — PHYSICAL DATA (HEATING) 7.5 - 12.5 TONS 580J *08 580J *09 580J *12 580J *14 Gas Connection # of Gas Valves 1 1 1 1 Nat. gas supply line press (in. w.g.) /(PSIG) 4 —13 / 0.18 — 0.47 4 —13 / 0.18 — 0.47 4 —13 / 0.18 — 0.47 4 —13 / 0.18 — 0.47 Propane supply line press (in w.g.) /(PSIG) 11 —13 / 0.40 — 0.47 11 —13 / 0.40 — 0.47 11 —13 / 0.40 — 0.47 11 —13 / 0.40 — 0.47 Heat Anticipator Setting (Amps) 1st stage 0.14 0.14 0.14 0.14 2nd stage 0.14 0.14 0.14 0.14 Natural Gas, Propane Heat # of stages / # of burners (total) 1 / 3 1 / 3 2 / 4 2 / 4 Connection size 1/2" NPT 1/2" NPT 3/4" NPT 3/4" NPT 9 Rollout switch opens / closes 195 / 115 195 / 115 195 / 115 195 / 115 Temperature rise range (F) 20 — 50 20 — 50 25 — 65 25 — 65 w # of stages / # of burners (total) 2 / 4 2 / 4 2 / 5 2 / 5 Connection size 3/4" NPT 3/4" NPT 3/4" NPT 3/4" NPT w Rollout switch opens / closes 195 / 115 195 / 115 195 / 115 195 / 115 2 Temperature rise range (F) 35 — 65 30 — 65 30 — 65 25 — 65 # of stages / # of burners (total) 2 / 5 2 / 5 2 / 5 2 / 5 = Connection size 3/4" NPT 3/4" NPT 3/4" NPT 3/4" NPT 0 Rollout switch opens / closes 195 / 115 195 / 115 195 / 115 195 / 115 T Temperature rise range (F) 45 — 75 40 — 75 35 — 70 35 — 70 16 CURBS & WEIGHTS DIMENSIONS - 580J *08 -12 40 -3/8 NOTES: 110261 • 1. DIMENSIONS ARE IN INCHES DIMENSIONS -T IN ( 1 ARE IN MILLIMETERS. ECONOMIZER HOOD 2. S CENTER OF GRAVITY (OPTIONAL] 20 -314 (521) • 3. * DIRECTION OF AIR FLOW .1 ( -p \ - 36-3!8 t2 } 5/8 / :. � 1 [925] 13211 RETURN °" AIR 1 1 �-/ E ALT. CONDENSATE �� DRAIN OPENING ' � IN BASEPAN ; '�� . \ - N @ 28-3/4 37 -518 40 -318 III II6111 111 - SEE THRU [7311 [955] ((027) 1r5 L /l)Il 11/ THE BASE SUPPLY - 3 MK \\. - 1,7 i////11 CHART I AIR 0 � 111\��.. ..- / /All I I1 O 18 IN \`U _% + _1 L4') 14691 14121 1[34 11 55] -,,,,,====.' - [279) _ I 1 1 29 -5/8 -•- -- 3-1/4 1 - 6-1/4 17511 14 [831 11591 1 35fi 12 ] I N TOP 25(-315162) 5 -1 4 -5 /8 [647] [118] I ELECTRICAL - ° DISCONNECT CONTROL BO!: CONDENSER A, �` If C. LOCATION ACCESS PANEL B ' • COIL G M INDOOR BLOWER y OPTIONAL •,• I 3 OPTIONAL FACTORY ACCESS FACTORY 27 -7/8 INSTALLED INSTALLED I CONVENIENCE C 111 (1091 DISCONNECT //c-HANDLE OUTLET f 7� F - \ 1 - -- - - ii 6-5/8 HANDLE �-1 d_ . � 8:: .. ..� 11681 7� I ' 1 I I I I �0� 3-3/4 --. I [951 59-1/2 2-5/8 l� 8 -3/8 115101 1671 37 12141 . TYP [940] LEFT CURB WIDTH 88-1/8 FRONT [2238] - 1 -I/4 1321 11.1 /8 - -' ' [3021 I FILTER ACCESS PANEL TJ (TOOL -LESSI FILTER E 510 CONDENSER CONDENSATE DRAIN COIL h RETURN INDOOR COIL AIR ACCESS PANEL ' 21 -314 Q AIR , 26 [1061 (3341 C SUPPLY 4 Alf II \ 16 6 I/8 A,---- I �7l. L)SJt,I Ilse t ti!r) 1 6.5/8 ---I L 7 t BACK 11611 37 -1/8 11771 1(551 THRU CHART - 19621 4, THESE HOLES REQUIRED FOR USE 1101!6 CRBTMPWROO2A01, 004A01 F i t RETURN RELIEF SUPPLY 110751 RELIE igIC 4 AIR THREADED WIRE REO'D HOLE RIGHT AIR FLOW CONDUIT SIZE USE SIZES (MAX.) UNIT J K H W 1/2' ACC. 1/8' (22.2) 580J -08A 41 1/4 33 15 1/8 CONNECTION SIZES X 1/2' 24V 7/8' (22.2) [10481 [658] (403] A 1 3/8° DIA [35] FIELD POWER SUPPLY HOLE Y 1 1/4° (002,004) POWER 1 3/4° (44 4) 580J -09A 49 3/8 37 23 [12531 [94667 ] 160991 B 2 1/2' [64] DIA POWER SUPPLY KNOCKOUT Zoo,* (004) 3/4' FPT GAS 1 5/8° (41.3) 580J-12A 49 3/8 37 1/4 15 7/8 C 1 3/4° DIA [51] GAUGE ACCESS PLUG FOR 'THRU- THE-BASEPAN' FACTORY OPTION, [1253] (946] [403] FITTINGS FOR ONLY X, 9, 8 I ARE PROVIDED i 580J -08D 41 1/4 33 15 7/8 D 7/8' DIA (221 FIELD CONTROL WIRING HOLE FOR HEAT SIZE 125K BTU A FIELD [1048] [658] [403] E 3/4' -14 NPT CONDENSATE DRAIN 0 SUPPLIED 1/2' ADAPTER IS REQUIRED 0 580J - 12D 49 3/8 37 1/4 15 7/8 1/2' 14 NPT GAS CONNECTION BETWEEN BASE PAN FITTING AND GAS VALVE (1253] [946] [403] - F 3/4' -14 NPT GAS CONNECTION wo (002) PROVIDES 3/4' FPT THRU CURB + - FOR TWO STAGE COOLING MODELS WITH - 6 2 ' DIA [51] POWER SUPPLY KNOCK -OUT FLANGE 8 FITTING NOVATION CONDENSER COILS. Co8525 - Fig. 5 - Dimensions 580.1 -12 20 CURBS & WEIGHTS DIMENSIONS - 580J *08 -12 (cont.) . STD UNIT CORNER CORNER CORNER CORNER UNIT WEIGHT WEIGHT (A) WEIGHT (B) WEIGHT (C) WEIGHT (D) C.G. LBS. KG. LBS. KG. LBS. KG. LBS. KG. LBS. KG. X Y Z 560J -08A 810 367 171 78 164 14 233 106 242 110 41 7/8 (1064) 33 1/8 (860) 20 1/4 (514) 580J-09A 910 413 193 88 181 82 260 118 276 125 41 3/8 (1051) 22 1/8 (581) 22 1/8 (5811 580J -12A 965 438 201 94 204 93 275 125 279 127 42 3/8 (1076) 24 1/8 (613) 24 1/8 (6131 580J -08D 860 390 153 69.3 141 66.6 273 124 284 129 42 3/4 (1088) 31 1/2 (954) 20 1/8 (5121 580J -12D 940 426 196 88.9 190 86.2 271 123 219 121 42 (1061) 33 1/8 (862) 20 1/4 (513) CORNER A CORNER B T (& T „s,1 c 1 . � y. l -3 co CORNER D L ' - u CORNER C ( .=. E=1• 00k In 10P FRONT KW 11 C08526 Fig. 6 - 580J *08 -12 j \ i i <' '',,, ,, v . , A ,,,.._ t ,, , i - ,* ) - b - ;:; ) ,/ - A 177 .,,,,, ''' '' , : 1 / 4 - , T '-- .--------- B 111' --. i ✓/ C08337 Fig. 7 - Service Clearance LOC DIMENSION I CONDITION 48" (1219 mm) Unit disconnect is mounted on panel 36" (914 mm) If dimension —B is 12" (305 mm) A 18" (457 mm) No disconnect, convenience outlet option 18" (457 mm) Recommended service clearance (use electric screwdriver) 12" (305 mm) Minimum clearance (use manual ratchet screwdriver) 36" (914 mm) Unit has economizer B 12" (305 mm) If dimension —A is 36" (914 mm) Special Check for sources of flue products within 10 —ft of unit fresh air intake hood . C 36" (914 mm) Side condensate drain is used 18" (457 mm) Minimum clearance 48" (1219 mm) No flue discharge accessory installed, surface is combustible material D 42" (1067 mm) Surface behind servicer is grounded (e.g., metal, masonry wall, another unit) • 36" (914 mm) Surface behind servicer is electrically non — conductive (e.g., wood, fiberglass) Special Check for adjacent units or building fresh air intakes within 10 —ft of this unit's flue outlet 21 CURBS & WEIGHTS DIMENSIONS - 580J *08 -14 NOTES: ROOFCURB 1. ROOFCURB ACCESSORY IS SHIPPED DISASSEMBLED. ACCESSORY A UNIT SIZE 2. INSULATED PANELS: 1' THK. POLYURETHANE FOAM, 1 -3/4 • DENSITY. 3. DIMENSIONS IN C ] ARE IN MILLIMETERS. CRRFCUR6003A01 1 - 2" 4. ROOFCURB: 16 GAGE STEEL. (356) 580J'08 - 14 S. ATTACH DUCTWORK TO CURB. (FLANGES OF DUCT REST ON CURB) • 2' p „ 6. SERVICE CLEARANCE 4' ON EACH SIDE. CRRFCURB004A01 (610) 7. % / //q DIRECTION OF AIR FLOW. 8. CONNECTOR PACKAGES CRBTMPWROO1A01 AND 2A01 ARE FOR THRU— THE —CURB GAS TYPE. PACKAGES CRBTMPWR003A01 AND 4A01 ARE FOR THE THRU— THE — BOTTOM TYPE GAS CONNECTIONS. CONNECTOR PKG. ACC. B C 0 ALT DRAIN HOLE GAS POWER CONTROL ACCESSORY PWR CRBTMPWROO1A01 2'-8 7/16 1 " -10 15/16 1 3/4'[44.5] 3/4 "[191NPT 131/4�1C3]1N7] 1/2 I/2 CRBTMPWROO2A01 (827] [583] CRBTMPWR003A01 1 /2 "(12.7]NPT 3 /4 "C19]NPT CRBTMPWROO4A01 3 /4'(19]NPT 1 1/4'[31.7) , C 1 p UNIT )ii 0 fii - 0 I / A� - GASKET YO/� NAIL 0.-3 [84.11 LID l I D.- {` - ` l + (S IE CURB) TYPICAL (4) SIDES I I / �i _ •' . -4 , , h _ 1 1 1 1 ` \ (FIELD SUPPLIED) � 0 -7/16 - / / COUNTER FLASHING )� // I / 1 `, t .,' (FIELD SUPPLIED) • a / I i � J - - ROOFING FELT - - II • 1 h _ ." \ (FIELD SUPPLIED) ( CANT STRIP 1 / / \ (FIELD SUPPLIED) SECTION 'C '' a. ' / / ROOFING MATERIAL SCALE 1,4 1761 1 - - % (FIELD SUPPLIED) -- 1 0' -3 I � 'Er I RIGID INSULATION (76) (FIELD SUPPLIED) ' RETURN AIR 1 I , OPENING 3 5/8' I 110061 1 4 SUPPLY AlR 1 ' / 1• -3 1/4' ' I OPENING •C• / 1387) ' ' / OPENING FOR BASEPAN 1_11 I - — — ' / ENTRY SERVICE [GEE NOTE •B1 - F-1- ( \- ROOFING MATERIAL 0 -0 7/16" (FIELD SUPPLIED) 55 33 - Illl 6 15/16 -I 1' -2 7/8' 0 -0 7/16' / .(132] (BOLT HEADS) (786) — �1 13783 (113 / 0 -2 1/8' , 0 - (80LT HEADS) / (543 (76) / . 0'-11 2/5 0 (117. 4 " -0 13/16' -.41 4.-0 7/16' / 29D SEE NOTE •2 (DOLT HEADS)) 112401 (BOLT HEADS) / F O) A f A / H Al , 0' -4 3/16 4- / / [1061 1 • ,� / / H / GAS PLATE I / (SEE NOTE X8) I 1•_8 3/16 \ I / (5131 0 -4 5/16' / I (110) / A 1 INSIDE ) / 1 " -8 3/16 l�� 3 1513 / I I ` (I 3) 0 " -0 I /4 / � i • I O ` TYP O t I 0 (1 15. S) 9/16' �' 1 / I ♦ 1 (61] 751 15/16• O ® 1 ` 1 , 4 t 1 1 rt SUPPLY AIR RETURN AIR m.. // I I 'i0.000/di / VIEW - A -A �� \" HEAD OF BOLT TO BE ON ,� / ' INSIDE OF FLANGE Vi g ` O 148] + I 25 0 - �- `` [19871 4' -1 3/4 1 1 I (1264] .. NOTE. CAMBRIDGEPoRT "SURE -LOCK CORNER FASTENING DEVICE IS ACCEPTABLE AREF ♦ ♦ ALTERNATE CONSTRUCT • . 6f SEE VIEW 'B -A6' . VIEW '8 (TMP ALL CORNERS) 009525 . Fig. 8 - Roof Curb Details 22 OPTIONS & ACCESSORY WEIGHTS OPTION / ACCESSORY WEIGHTS OPTION / ACCESSORY 04 05 06 07 08 09 12 14 lb kg lb kg lb kg lb kg lb kg lb kg lb kg lb kg Perfect Humidity 15 7 23 10 25 11 29 13 - - - - - - - - Power Exhaust - vertical 50 23 50 23 50 23 50 23 75 34 75 34 75 34 75 34 Power Exhaust - horizontal 30 14 30 14 30 14 30 14 30 14 30 14 30 14 30 14 EconoMi$er(IV or 2) 50 23 50 23 50 23 50 23 75 34 75 34 75 34 75 34 Two Position damper 39 18 39 18 39 18 39 18 58 26 58 26 58 26 58 26 Manual Dampers 12 5 12 5 12 5 18 8 18 8 18 8 18 8 18 8 Medium Gas Heat 12 5 9 4 9 4 9 4 15 7 15 7 18 8 18 8 High Gas Heat - - 17 8 17 8 17 8 29 13 29 13 35 16 35 16 Hail Guard (louvered) 16 7 16 7 16 7 16 7 34 15 34 15 34 15 34 15 Cu /Cu Condenser Coil 6 3 13 6 13 6 15 7 12 5 23 10 23 10 23 10 Cu /Cu Condenser and Evaporator Coils 12 5 19 9 21 10 26 12 25 11 49 22 49 22 49 22 Roof Curb (14 -in. curb) 115 52 115 52 115 52 115 52 143 65 143 65 143 65 143 65 co Roof Curb (24 -in. curb) 197 89 197 89 197 89 197 89 245 111 245 111 245 111 245 111 U' CO2 sensor 5 2 5 2 5 2 5 2 5 2 5 2 5 2 5 2 Flue Discharge Deflector 7 3 7 3 7 3 7 3 7 3 7 3 7 3 7 3 Optional Indoor Motor /Drive 10 5 10 5 10 5 10 5 15 7 15 7 15 7 15 7 Motor Master Controller 35 16 35 16 35 16 35 16 35 16 35 16 35 16 40 18 Return Smoke Detector 5 2 5 2 5 2 5 2 5 2 5 2 5 2 5 2 Supply Smoke Detector 5 2 5 2 5 2 5 2 5 2 5 2 5 2 5 2 Fan /Filter Status Switch 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 Non -Fused Disconnect 15 7 15 7 15 7 15 7 15 7 15 7 15 7 15 7 Powered Convenience outlet 35 16 35 16 35 16 35 16 35 16 35 16 35 16 35 16 Non - Powered Convenience outlet 5 2 5 2 5 2 5 2 5 2 5 2 5 2 5 2 Enthalpy Sensor 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 Differential Enthalpy Sensor 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 1 For Perfect Humidity add MotorMaster Controller. 2 Where available. 25 [Page Too Large for OCR Processing] [Page Too Large for OCR Processing]