Loading...
Plans Map Page l of 1 i AZ-1 C LLR V k it 7085 i JUN 06 2012 � CRY OF `1'gGAc�,l�i y at:: . ` BUILDING DIV1SuON ONE; , i 71e5 -� ` ;> .r, ' 1 7383 i::: r sANDBU • 6 ; 'LO • 700 7.. 71C10 7100 0,Jrea,Q one ar - ,, .. 7150 - ;:. CITY OF Y IGARD Approved [Xf Conditionally Approved [ ] See Letter to: Follow [ ] OFFICE COPY Attached [ ] Permit Number: rlkeavl - Ort3 ;1' Address:7 /W) Sw SRNt7$1..n G S T /CJD By: eh ,/ Date: ( 6 - I a- 1 1 Ark MITSUBISHI ik ELECTRIC fillf.Sillin 0 HVAC Advanced Products Division Split - ductless A/C and Heat Pumps :`SU. MITTA MSY D36NA & _MUY:b36NA W . _, .. 36 000'BTUIN; WALL` MOUNTED AIR CONDITIONING SYSTEM : _ Job Name: Location: Date: Purchaser: Engineer. Submitted to: • For ❑ Reference ❑ Approval ['Construction Unit Designation: Schedule No.: GENERAL FEATURES . ' " y ' • • Catechin and anti-allergy enzyme filters for high air-purification — ' ' • capabilites p-- - 1--•= C 1. • _. • Updated sleek, compact indoor unit design Indoor Unit MSY -036NA • � . � w • Remote - controlled wide airflow enables ideal horizontal air * ; '), � .. distribution i a t =,/: i ;: ,z.„ ' • Self-check function— onboard diagnostics • Advanced microprocessor control . • Auto restart following a power outage Wireless Rerrote Controller Outdoor Unit MUY -D36NA • Wireless remote controller • Limited warranty: five years on parts and defects and seven Indoor Unit years on compressors MCA 1 A Fan Motor 0 76 F.L.A. OPTIONAL ACCESSORIES Airflow Outdoor Unit Cooling (Lo - Med - Hi) 389 - 639 - 848 Dry CFM 350 - 576 - 763 Wet CFM • Drain Socket Assembly (MAC- 811DS) Sound Pressure Level Indoor Unit Cooling (Lo - Med - Hi) 32 - 42 - 49 dB(A) • Three -pole Disconnect Switch (TAZ- MS303) • M -NET Control Adapter (MAC- 3991F) DIMENSIONS UNIT INCHES / MM • MA Contact Terminal Interface (MAC- 3971F) W 46 - 1/16 / 1,170 • Wired Remote Controller (PAR-21MAA; Requires MAC -3971) D 11 -5/8 / 295 • Centralized On /Off Remote Controller (MAC -821 SC; Up to H 14 3/81365 eight units, requires one MAC -3971F per indoor unit) Weight 40 lbs. / 18 kg • Condensate Pump (230V; SI3100 -230) External Finish Munsell No. 1.0Y 92 / 0.2 • Anti - allergy Enzyme Filter (Two pieces per set; MAC- 1415FT) Field Drainpipe Size O.D. 5/8" / 15.88 mm Remote Controller Wireless Coolie (Optional Wired Remote Controller PAR -21 MAA Rated Capacity 34,600 Btu/h see Data Submittal Sheet) Minimum Capacity 9,800 Btu/h • SEER 15.1 Btu/h/W Outdoor Unit Total Input 4,240 W • Rating Conditions ( Cooling) - Indoor. 80 F( 27C)DB,67°F(19°C) Val, Outdoor 95 °F Compressor DC Inverter- driven Rotary (35°C) DB, 75°F (24°C) WB MCA 21A Fan Motor 0 93 F.L.A. Power Supply 208 / 230V, 1- Phase, 60 Hz Sound Pressure Level Breaker Size .25 A Cooling 56 dB(A) Voltage DIMENSIONS INCHES / MM Indoor - Outdoor S1-S2 AC 208 / 230V W 33 - 1/16 / 840 • Indoor - Outdoor S2-S3 DC 12 -24V D 13 / 330 Indoor - Remote Controller Wireless H 33 -7/16 / 849 • OPERATING RANGE Indoa Intake Air Ternp. Outdoor Intake Air Temp. Weight 126 lbs. / 57 kg 90°F (32°C) DB. 115 °F (46°C) DB External Finish Munsell No. 3Y 7.8 / 1.1 Maximum 73°F (23°C) WS Refrigerant Type R410A Cooling 67°F (19°C) DB, Refrigerant Pipe Size O.D. Minimum 57°F (14°C) WB 14°F (-10°C) De Gas Side 5/8" / 15.88 mm Liquid Side 3/8" / 9.53 mm Max. Refrigerant Pipe Length 100' / 30 m Max. Refrigerant Pipe Height Difference 50' / 15 m Connection Method Flared 4°A I R R �w • . DIMENSIONS: MSY -D36NA & MUY -D36NA • - MSY -D36NA 451l2 Unit : Inch 1 2 -11/10 f Indoor un8 4-11/16 _ 1 P. j= = = =1 -= == t=-7---- _ - =. = == =:_ I I ° = = = =_ -_ I� 46-1/16 ( ) 1 I 1 A. . 11 l -._i 1 A l -- a -- a t . t4 24 /18 . 20-798 .I 17 -11/1 � p j 11518 ,114 Wall hole 03 Air ! m Itllobon plate _. 2.6/16 I _ t! °rte- —mod I PILL., �ITIT^ 2 - 16nt1 f 33 -11/16 9.12 .. i d1 1 • • Required Space (Indoor Unit) — _ � Wireless remote controller w - L Dram hose Mil - - - - � ME 2596 1 i Air •- b S Piping Insulation -- I « Liquid fine 0318 19 -11116 01-1/4 0.4 :: (Flared tamedion 6318) 09/161.4 I ge use eaa «mac 171 1 (16-718 rennection 05/8) 01-15116 n D. b Joint 4518 a1- 151180.4 For left; left, back; or left, (Flared o nnedion 45/8) 01- 1141.4 bottom piping (using spacer): 5-1/8 or more Drain hose Invd,180001 -118 Canneded pad 49116 OA MUY -D36NA Unit: Inch REQUIRED SPACE Open as a rule 20 inch or more If ■ the front and both sides are open 20-432 Uhf 3nU 111 uw 11 -25/32 fX 1-9/16 4 Inch or more / Ali Is 7 4 A ` 8 inch or more if .'��, = _ II — , � gill' are obstaaes N VIIII i• ti m AI to both sales iU� ■ II a ! ti b F IQ :' <�i r I • ` 7 4 W ni 4 5/a /1f slat 16 I sans Open as a lute \� 33 - 1n6 20 inch or more if the back, 11111. 1 111.911111=11 - . both sides end top are open fet A iii : , -- -- ----- .,----- 11 ,----- - --- ------ IN 0 cm _ 7.-_------ MN i t ill Co an Inim 'e' .A. MITSUBISHI -_ti °i CERTIFIED,` •'' ELECTRIC . rnv.ann d •r ctcrv.arg i?ARTN HVAC Advanced Products Division - Small AO . -- 3400 Lawrenceville Suwanee Rd -Mill staidad 21nza6 - Suwanee, GA 30024 a... �. .. ,. .... ,•_,_, w. ( /STE ® Tele: 678376 -2900 • Fax: 800-88B-9904 Tot Free: 800-433-4822 (#3) www.mehvac.com C SO - MSY -036NA / MUY -036NA- 200909 0 MITSUBISHI ELECTRIC / HVAC 2009 Specifications are subject to change without notice. ARROW MECHANICAL CONTRACTORS, INC. 10330 S.W. TUALATIN RD. • TUALATIN, OREGON 97062 PHONE: (503) 692 -1565 • FAX: (503) 691 -1879 DESIGN OF HVAC UNIT CONNECTION TO ROOF CURB AND CONNECTION OF ROOF CURB TO ROOF DESIGN CRITERIA: • SEISMIC USE GROUP: I OR II • SEISMIC DESIGN CATEGORY: D, E, OR F • HEAVIEST UNIT TOTAL WEIGHT: WP = 1600# TOTAL LATERAL FORCE (USING ASCE 7 -02 9.6.1.3) F , _ 0.4 apSDSWPIP 1 +2 z p RP(1.4) h ap =1.0 SDS =1.0 (max) • WP = 1600# IP =1.0 RP= 2.5 z = UNIT ATTACHMENT POINT IN STRUCTURE ABOVE BASE • /2 = ROOF HEIGHT ABOVE BASE z • — = 1.0 FOR ROOF TOP HVAC UNITS Fp _ ( 0.4)(1.0)(1.0)(1600)(1.0) k1+ 2(1.o)) 2.5 (1.4) Fp = 549# CHECK, Fpm = 0.3 SDS WPIP Fpm = ( 0.3) (1.0) (1600) ( 1.0) 1 1 4 = 343# < 549# OK . USE 549# ARROW MECHANICAL CONTRACTORS, INC. 10330 S.W. TUALATIN RD. TUALATIN, OREGON 97062 PHONE: (503) 692 -1565 FAX: (503) 691 -1879 OVERTURNING ON UNITS: 3.5' MIN. 1.5' MIN. 0 Wp = 1600# Fp =549# C.G. 3.5' MAX. UNIT TO CURB CURB TO ROOF END VIEW HVAC UNIT DIMENSION REQUIREMENTS MOT = (Fp) (Vert. Dist. to Center of Gravity) = (549) (3.5) =1922 FT - LBS MR = (Wp) (Reduction for Load Combination) (Least Horiz. Dist. to Center of Gravity) = ( 1 600) (0.9X1.5) = 2160 FT - LBS MR >MOT .'. TENSION AND UPLIFT CONNECTIONNOT REQUIRED DESIGN FOR SHEAR ONLY. f _ i• (4) #10 SCREWS BASE UNIT (20 GA) "i AT LOCATIONS SHOWN AI A. - l (4) #10 SCREWS • i x.41 ` u ` ry INACCESSIBLE 16 GA CURB `� AREA CONDENSER COIL END PLAN VIEW DETAIL A -A UNIT TO CURB DESIGN: 549 V(ACTUAL) = =137# I SCREW 4 SCREWS V (ALLOWABLE) =177# / SCREW IN 20 GA MATERIAL (REF : ER - 4943P) 177# >137# OK USE (4) #10 SCREWS