Plans
[Page Too Large for OCR Processing] "7 git0 s tv ivtizr`k�'' - " - 4 _ . - FPS2o I I - 40006 Bulletin 014 Rev. F ® Model F1 FR56 Series Quick Response o Standard Spray 5. DJ co m Model Fl FR56 Sprinkler Types Standard Upright r� Standard Pendent Conventional gra Vertical Sidewall Horizontal Sidewall Model Fl FR56 Recessed Sprinkler Types Standard Pendent /F1/F2 /FP Upright Pendent Horizontal Sidewall Model Fl FR56 Concealed Sprinkler Types - Standard Pendent F • Listing & Approvals � 1. Underwriters Laboratories Inc. and Certified for Canada (cULus). ` 2. Factory Mutual Approvals (FM) Vertical Sidewall Conventional 3. Loss Prevention Council (LPCB, UK) 4. VdS Schadenverhutung GmbH UL Listing Category •`'`. Sprinklers, Automatic & Open (VNIV) . lo Quick Response Sprinkler -, 41e _ • Product Description ,,,,,A, Reliable Models F1 FR56 Series Sprinklers are quick re- sponse sprinklers which combine the durability of a stan- Horizontal Sidewall Recessed dard sprinkler with the attractive low profile of a decorative Pendent/F1/F2 sprinkler. The Models F1FR56 Series Recessed automatic sprin- klers utilize a 3.0 mm frangible glass bulb. These sprin - klers have demonstrated response times in laboratory tests t , � '�, . „,3 which are five to ten times faster than standard response A sprinklers. This quick response enables the Model Fl FR56 Series sprinklers to apply water to a fire much faster than ,,, „,_ ,, standard sprinklers of the same temperature rating. , : „. ,. >� The glass bulb consists of an accurately controlled amount Recessed Recessed of special fluid hermetically sealed inside a precisely manu Horizontal Sidewall Pendent/FP factured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. Application At normal temperatures, the glass bulb contains the flui in both the liquid and vapor phases. The vapor phase can Quick response sprinklers are used in fixed fire protec be seen as a small bubble. As heat is applied, the liquid tion systems: Wet, Dry, Deluge or Preaction. Care must be expands, forcing the bubble smaller and smaller as the liq exercised that the orifice size, temperature rating, deflec uid pressure increases. Continued heating forces the liquid tor style and sprinkler type are in accordance with the lat to push out against the bulb, causing the glass to shatter, est published standards of the National Fire Protection As- opening the waterway and allowing the deflector to distrib sociation or the approving Authority Having Jurisdiction, ute the discharging water. Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model Fl FR56 Quick Response Upright, Pendent & Conventional Sprinklers Installation Wrench: Model D Sprinkler Wrench ' Installation Data: Nominal Thread Nominal K Factor Sprinkler Approval Sprinkler identification Number p pp (SIN) Orifice Size Height Organization US Metric Upright Pendent Standard - Upright (SSU) and pendent Deflectors Marked to Indicate Position 1/2" (15mm) '/2" NPT(R1/2) 5.6 80 2.25" (57mm) 1, 2, 3, 4 RA1425 "' RA1414 "x2) Conventional - Install in Upright or Pendent Position 15mm 1/2" NPT(R1/2) 5.6 80 57mm 3,4 RA1475 01 cULus listed corrosion resistant (Polyester coated) sprinkler. '2) Polyester coated FM approved sprinkler. -- Mil all I. -_ Upright Pendent Conventional . Model Fl FR56 Quick Response Recessed Pendent Sprinkler Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Thread K Factor Sprinkler Sprinkler Identification Number ■ Orifice Size US 1 Metric Height (SIN) 1/2" (15mm) 1/2" NPT(R1/2) 5.6 I 80 2.25" (57mm) RA1414 1 I11 Refer to escutcheon data table for approvals and dimensions. +6- 2 5/6' DK [66.7mm) 2 1 /4' HOLE ON HOLE IN CE2,NG ( 15 /16' J 2 VW' DK [36.7mm] I rs /re' au CUP �'_ (Ay.zmmJ 1-1------I-1 r ~ _z -�-� TURN COLLAR 1 r x T /2' REDUCE I _ I 1" X 1/2' REDUCER UNTIL TIGHT AGAINST SPRINKLER I % I I WRENCH BOSS \I / / II �j7 �j7 /� I ri I — - 1 \ 1 _ _ / �!'_/�LL/ t_ J L J 1 „mm-,4, Is J FACE OF FITTING IO''L CEILING — ADJUSTMENT(11 CEILING L DrMENS ON i � Il. L "!d1, I it , + 11 I� ill /TI7NC � `, + f III III TO FACE FACE OF OF F CEIUNG ll i1 I I ^`� `� i DIMENSlON ADJUSTMENT A 1 27/32' DN. OI■FGOI ..- —� "• [72.2mm) + 014FTp2 (I) REFER TO El t F2 ESCUTCHEON DATA TABLE FOR APPROVALS AND DIMENSIONS (1) REFER TO FP ESCUTCHEON DATA TABLE FOR APPRONA S AND DIMENSIONS. Model F1FR56/F1 or F2 Model F1FR56/FP 2. Model Fl FR56 Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: Nominal K Factor Sprinkler Nominal Thread Size Sprinkler Approval Identification Orifice US Metric Height Organizations Numbers (SIN) 1 /2" (15mm) 1 /2" NPT (R1/2) 5.6 8.0 2.25" (57mm) 1,2,3,4 RA1485 15mm 1/2" NPT (R1/2) 5.6 8.0 2.25" (57mm) 4'` ( LPC Approval is for pendent position only. Sprinkler Type Deflector to Ceiling Distance (Min. - Max.) Upright 4" (102mm) 12" (305mm) Pendent 4" (102mm) - 12" (305mm) Vertical Sidewall Model Fl FR56 Quick Response Horizontal Sidewall Sprinkler Deflector: HSW Installation Wrench: Model D Sprinkler Wrench Installation Data: Horizontal Sidewall Nominal K Factor Sprinkler Approval Organizations Sprinkler Height and Type of Approval Nominal Orifice Thread Size — — -- — Identification US Metric Light Hazard Ordinary Numbers (SIN) Hazard 1/2" (15mm) 1 /2" NPT (R1/2) 5.6 80 2.63" (67mm) 1,2 1 RA1435 FACE OF FI7T/NG (1) TO FACE OF CEILING DIMENSION 1 1/4 MIN. [31.8mm] 2 1/4" HOLE 014. 1/8 . 41k [ [101.6mm- 304.Bmm] [3.2mm] DEFLECTOR CEILING TO 1" X 1/2" REDUCER j - . �._"I - I 15/16" DW. ) I Al [49.2mm) - -- I III 2 27/32" D1A. - I•d [72.2mm] Horizontal Sidewall I TURN COLLAR UNTIL TIGHT WRENCH BOSS. SPRINKL --•••1 ADJUSTMENT 01JFG03A (1) REFER TO ESCUTCHEON DATA TABLE FOR APPROVALS AND DIMENSIONS. (2) FM APPROVED FOR 4" - 6" [101.6MM - 152.4MMJ CEILING TO DEFLECTOR. Note: For Recessed HSW Sprinklers use installation wrench GFR2. 3. Model Fl FR56 Quick Response Concealed Pendent Sprinklers Installation Wrench: Model RC1 Sprinkler Wrench Technical Data: Nominal "K" Factor Thread Temp. Rating Max. Bulb Sprinkler Model Ambient Approvals Identification Orifice US Metric Size Sprinkler Cover Temp Color Number(SIN) 1/2" (15mm) 5.6 80 '/2" NPT F1FR 135 °F /57 °C 135 °F /57 °C 100 °F /38 °C Orange 1, 2 RA1414 1/2' (15mm) 5.6 80 1 /2" NPT F1FR 155 °F /68 °C 135"F/57°C 100 °F /38 °C Red 1, 2, 4 RA1414 1 /2" (15mm) 5.6 80 1 /2" NPT F1FR 175 °F /79 ° C 165 °F /74 °C 100 °F /38 °C Yellow 1, 2 RA1414 1" (15mm) 5.6 80 Y2" NPT F1FR 200 °F /93 °C 165 °F /74 °C 100 °F /38 °C Green 1, 2 RA1414 ( For VdS only = 155 °F /68 °C Norbulb and 1/2" [12,7mm) adjustment. /- x 1/2" REDUCING TEE OR ELBOW r 1" x 1/2" REDUCING Tr __ TEE TEE OR ELBOW –.. -- -� r – � 2 5/8 DIA. -- -- -- ------------- 2 5/16" DIA - , 77 ,--- : , - HOLE IN CEILING " - � 2 5/8" DIA. HOLE IN CEILING 4 2 5/16" DIA - -- CUP. �. - t - _ — r0 FACE OF CEILING I 1/2" MAX. CUP rt F ACE OF FITTING '.l� 1 1/2" MAX. i ti f - FACE OF FITTING ��r r) D IMENS ION ,4 91 01 –.- TO FACE OF CEILING CEILING t l i ' T ' 1 ) T DIMENSION , �� 4 1p , � � %a – , CEILIN \� / —'-/-= 1/2" MAX. ...__- ~. 15/16" 5/16" MAX �^ ._� 3/4" Alial COVER ADJUSTMENT COVER ADJUSTMENT COVER PLATE — t COVER PLATE — I f ASSEMBLY 3 5/16" DIA. - ASSEMBLY 3 5/16" DIA. SPRINKLER / SPRINKLER / 1 /2" ADJUSTMENT orac°i 5/16" ADJUSTMENT o,: Figure 1 Figure 2 Installation Aid A protective cap is included for use during installation. Sprinkler with a threaded Model CCP cup which is fac- Important: The F1FR56 Sprinkler with Model CCP cover tory attached to the sprinkler. The assembly is complet- plate is not an FM Approved combination. ed by the installation of the attractive, low profile, 135 °F Installation (57 °C) or 165 °F (74 °C) rated Model CCP push on cover Quick response sprinklers are intended for installation plate assembly. The cover plate and sprinkler cup as- as specified in NFPA 13. Quick response sprinklers and semblies are joined using a cover plate skirt with flexible standard response sprinklers should not be intermixed. tabs for threaded engagement. A choice of two cover The Model F1 FR56 Recessed Quick Response Sprin- plate assemblies provide either 1" (13mm) or 5 /16 " (8mm) klers are to be installed as shown. The Model F1 or F2 Es- of cover adjustment. cutcheons illustrated are the only recessed escutcheons Do not install these sprinklers in ceiling which have to be used with the Model F1FR56 Sprinklers. The use positive pressure in the space above. of any other recessed escutcheon will void all approvals After a 2 (67mm) diameter hole is cut in the ceil- and negate all warranties. ing, the sprinkler is easily installed with the Model RC1 When installing Model Fl FR56 Sprinklers, use the Mod- Wrench. A Teflon* based thread sealant should be el D Sprinkler Wrench. Use the Model GFR2 Wrench for applied to the sprinkler threads only. The Model RC1 installing F1FR56 Recessed Pendent Sprinklers. Any Wrench is then used to engage the sprinkler wrenching other type of wrench may damage these sprinklers. surfaces and to install the sprinkler in the fitting. When NOTE: A leak tight' /" NPT (R112) sprinkler joint can inserting or removing the wrench from the sprinkler /cup be obtained with a torque of 8 -18 ft-lbs (10,8 - 24,4 N -m). assembly, care should be taken to prevent damage to Do not tighten sprinklers over maximum recommended the sprinkler. DO NOT WRENCH ON ANY OTHER PART torque. It may cause leakage or impairment of the sprin- OF THE SPRINKLER. The cover plate is then pushed klers. onto the cup. Final adjustment is made by hand turning The Model Fl FR56/ CCP Concealed Sprinkler uses the the cover plate until the skirt flange makes full contact 1" orifice, 'h" NPT (R1/2), 135 °F (57 °C), 155 °F (68 °C), with the ceiling. Cover plate removal requires turning in ' 175 °F (79 °C) or 200 °F (93 °C) Model F1FR56 Pendent the counter clockwise direction. *DuPont Registered Trade Mark 4. After installation, inspect all sprinklers to ensure that Sprinkler Types there is a gap between the cover plate and ceiling and Standard Upright that the four cup slots are open and free from any air flow Standard Pendent impediment to the space above. Conventional Concealed cover plate /cup assemblies are listed only Recessed Pendent for use with specific sprinklers. The use of any other con- Vertical Sidewall cealed cover plate /cup assembly with the Model Fl FR56 Horizontal Sidewall Pendent Sprinkler or the use of the Model CCP Concealed Recessed Horizontal sidewall cover plate assembly on any sprinkler with which it is not Concealed pendent specifically listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals. Maximum Working Pressure Glass bulb sprinklers have orange bulb protectors to 175 psi (12 bar) minimize bulb damage during shipping, handling and 100% Factory tested hydrostatically to 500 psi (34.5 bar) installation. REMOVE THIS PROTECTION AT THE TIME Finishes ( THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Removal of the protectors before this Standard Finishes Sprinkler Escutcheon Cover plate time may leave the bulb vulnerable to damage. RASCO Bronze Brass wrenches are designed to install sprinklers when covers Chrome Plated Chrome Chrome are in place. REMOVE PROTECTORS BY UNDOING THE White Polyester Plated White CLASP BY HAND. DO NOT USE TOOLS TO REMOVE Coated (4 White Painted THE PROTECTORS. Special Application Finishes Sprinkler Escutcheon Cover plate Temperature Ratings Bright Brass c3, Bright Brass Bright Brass Sprinkler Black Plated Black Plated Satin Max. Ambient Black Paint (2) Black Paint Off White Classification Temperature Temp. Bulb Color Off White (2) Off White Black Paint Satin Chrome Satin Chrome Black Plated Ordinary 57 135 100 °F (38 °C) Orange ' Other finishes and colors are available on special order. Ordinary 68 155 100 °F (38 °C) Red Consult the factory for details. Intermediate 79 175 150 °F (66 °C) Yellow 2 ) cULus Listed only. Intermediate 93 200 150 °F (66 °C) Green (31 200 °F (93 °C) maximum. High (1) 141 _ 286 225 °F (107 °C) Blue w, cULus listed "corrosion resistance" applies to SIN Numbers '' Not available for recessed sprinklers. RA1425 (Upright) and RA1414 (Pendent) in standard black or white. ` FM Approvals finish as "Polyester coated" applies to SIN Number Escutcheon Data (1) RA1414 (Pendent) in standard black or white. Face of Rtting n� Approvals a ; Ordering Information Dimension Dimension Specify: Fl 1,3,4 Max Recess 11/2"(38.1mm) 'h6 °- 15//16" 1. Sprinkler Model Min Recess 3 /4 "(19.1mm) (5mm -24mm) 2. Sprinkler Type F2 1,2,3,4 Max Recess 1'/z " " (38.1mm) 116" -1116" 3. Orifice Size Mn Recess 1" (25mm) (5mrn -17mm) FP push -on/ Max Recessed 7 /16 "(11mm) 1 (38,1mm) 4. Deflector Type Thread -off 1,4 Min Recessed t 1 "(254mm) 5. Temperature Rating (I) SIN: RA1435 - cULus and FM permits use with Fl or F2 escutcheons for light 6. Sprinkler Finish hazard only. 7. Escutcheon Type 8. Escutcheon Finish (where applicable) Maintenance 9. Cover plate Model The Models F1FR56 and F1 FR56 Recessed Sprinklers 10. Cover plate Thread size should be inspected quarterly and the sprinkler system 11. Cover plate Temperature maintained in accordance with NFPA 25. Do not clean 12. Cover plate Adjustment sprinklers with soap and water, ammonia or any other 13. Cover plate Finish cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has Note: When Model Fl FR56 Recessed sprinklers are ordered, the sprin- been painted (other than factory applied) or damaged klers and escutcheons are packaged separately. in any way. A stock of spare sprinklers should be main- tained to allow quick replacement of damaged or oper- ated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging to mini- mize the potential for damage to sprinklers that would cause improper operation or non - operation. 5. Bulletin 013 Rev. F co ® Model F156 Series • Standard Response CD Standard Spray CD JJ CD m Model F156 Sprinkler Types Standard Upright Standard Pendent 1 , Conventional Vertical Sidewall Horizontal Sidewall Model F156 Recessed Sprinkler Types Pendent/F1/F2/FP Upright Pendent Horizontal Sidewall Approval Organizations 1. Underwriters Laboratories Inc. and certified for Canada (cULus) 2. Factory Mutual Approvals (FM) 3. Loss Prevention Council (LPCB, UK) 4. VdS Schadenverhutung GmbH Vertical Sidewall Conventional UL Listing Category Sprinklers, Automatic & Open (VNIV) Product Description • The F156 Series Glass Bulb Sprinkler combines the , durability of a standard sprinkler with the attractive low ° profile of a decorative sprinkler. Whether installed on ex- posed piping or in an office ceiling, it is functional and attractive. Horizontal Sidewall Recessed Beautifully versatile is the description for the Reliable Pendent/F1/F2 Model F156 Series Recessed glass bulb sprinkler. Re- cessing the F156 Series enhances its already low profile / decorative appearance, and facilitates a rapid and per- fect installation. Model F156 Series Recessed escutcheon is highly ad- justable. The two piece construction makes field installa- tion a very easy and rapid task. This also allows ceiling panels to later be removed without shutting down the fire system, thus facilitating maintenance of above Recessed Recessed ceiling services. Horizontal Sidewall Pendent/FP The F156 Series Automatic Sprinkler utilizes a 5.0 mm frangible glass bulb. The glass bulb consists of an ac- curately controlled amount of special fluid hermetically and smaller as the liquid pressure increases. Continued sealed inside of a precisely manufactured glass capsule. heating forces the liquid to push out against the bulb, This glass bulb is specially constructed to provide fast causing the glass to shatter, opening the waterway and thermal response. allowing the deflector to distribute the discharging wa- At normal temperatures, the glass bulb contains the ter. fluid in both the liquid phase and in the vapor phase. The The F156 Series Sprinkler temperature rating is identi- vapor phase can be seen as a small bubble. As heat is fied by the color of the glass bulb capsule as well as applied, the liquid expands forcing the bubble smaller frame color where applicable The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model F156 Upright, Pendent & Conventional Sprinklers Installation Wrench: Model D Sprinkler Wrench Eye r* � - I IP Upright Pendent Conventional Installation Data: Nominal Thread Nominal K Factor Sprinkler Approval Sprinkler Identification Number Orifice Size Height Organization (SS IN} US Metric Upright Pendent Standard - Upright (SSU) and pendent Deflectors Marked to Indicate Position 1 /2" (15mm) 1 /2" NPT(R') 5.6 80 2.25' (57mm) 1, 2, 3, 4 RA1325 RA1314 Conventional - Install in Upright or Pendent Position 15mm 1/2" NPT(R') 5.6 80 57mm 3, 4 RA1375 (1) Refer to Bulletin 024 for Special Response Sprinklers (F1S5 -56) 1 21 cULus corrosion resistant (Polyester coated) sprinkler. (31 Polyester coated FM Approved sprinkler. Model F156 Recessed Pendent Sprinklerf Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Thread K Factor Sprinkler Sprinkler Identification Number Orifice Size US Metric Height (SIN) 1/2" (15mm) '/2" NPT(R1/2) 5.6 80 2.25" (57mm) RA1314 I (1) Refer to escutcheon data table for approvals & dimensions ..._ 2 1/4' HOLE; OK �— 2 5/8 DMA [66.7mm] [5Z HOLE IN CEILING ,_ 1 75/1r OM r 2 5/16" Dk. [5B.7mmJ (r9.2mmJ CUP RAN COLLAR 1 II -I I t' X 1/2 REDUCER 0/71 Taff MOAT SPRINKLER x 1 *WC" IOST+— \ \\I I r I _ -A I 1 1 / J_F7.J ` _, -� j.. _ � ' FAQ OT mlwc TO ") L. J AWRSTIRMT d) ♦...•a�l''i, /. " ` . CEILING � I� f II ! II FACE OF F7C ■ III! 'I > n FACE OF CEILING I 'INN"' VS' LLLli1i \ \\ \ ■ p DINE 2 2 27/3r OM. 0131192 ADJUSTMENT J n2] -- ! -- t 013,G02 (I) /REFER ID n a F2 ESCUTESEON DAM DIRE FOR ARN WS AID 0J1[ESWIS. . (1) REFER TO FP ESCUTCHEON DATA TABLE FOR APPROVALS AND DIMENSIONS Model F156/F1 or F2 Model F156 /FP 2. Model F156 Vertical Sidewall Sprinkler _ Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent ,...4..--- Approval Type: Light Hazard Occupancy U.S. Patent No. 6,374,920 0 ■ Sprinkler Type Deflector to Ceiling Distance (Min. - Max.) Upright 4" (102mm) - 12" (305mm) Pendent 4" (102mm) - 12" (305mm) i Installation Data: Vertical Sidewall Nominal K Factor Sprinkler Nominal Thread Size Sprinkler Approval (1) Identification Orifice US Metric Height Organizations Numbers (SIN) 1/2" (15mm) 1/2" NPT (R1/2) 5.6 8.0 2.25" (57mm) 1,2,3 RA1385 "' LPC Approval is pendent only, 57 °C through 141 °C ratings. Model F156 Horizontal Sidewall Sprinkler Deflector: HSW yr 4 Installation Wrench: Model D Sprinkler Wrench 1 FACE OF FITTING ( ) TO FACE OF CEILING DIMENSION 1 1/4" MIN. . [31.8m m 2 1/4" HOLE DIA. 1/8" 4 - -12" [57.2mm] [101.6mm- 304.8mm] [3.2mmJ CEILING TO 1" X 1/2" REDUCER \ DEFLECTOR �r —' I , ` 1 — i ° l 1 15/16" DlA. III� ��— [49. m] I 1 I III �d l 2 27/32" DIA. VW � . L w � _ i �� [72.2mm] r- r , TURN COLLAR UNTIL \� TIGHT AGAINST SPRINKLER WRENCH BOSS. ADJUSTMENT (1) 013PG03A (1) REFER TO ESCUTCHEON DATA TABLE FOR APPROVALS AND DIMENSIONS. Horizontal Sidewall (2) FM APPROVED FOR 4" — 6" [101.6MM — 152.4MM] CEILING TO DEFLECTOR. Note: For Recessed HSW Sprinklers use installation wrench GFR2. Installation Data:Horizontal Sidewall Nominal K Factor Sprinkler A roval Organizations Height pp g Sprinkler Nominal Orifice Thread Size — — Identification US Metric Light Hazard Ordinary Numbers (SIN) Hazard 1/2" (15mm) 1 /2" NPT (R1 /2) 5.6 80 2.63" (67mm) 1,2 1 RA1335 3. . Model F156 & F156 Recessed Sprinklers Maintenance Application The Models F156 and F156 Recessed Sprinklers should be Model F156 and F156 Recessed sprinklers are used in fixed inspected quarterly and the sprinkler system maintained in fire protection systems: Wet, Dry, Deluge or Preaction. Care accordance with NFPA 25. Do not clean sprinklers with soap must exercised that the orifice size, temperature rating, deflector and water, ammonia or any other cleaning fluid. Remove any style and sprinkler type are in accordance with the latest pub- sprinkler which has been painted (other than factory applied) lished standards of the National Fire Protection Association or or damaged in any way. A stock of spare sprinklers should be the approving Authority Having Jurisdiction Installation. maintained to allow quick replacement of damaged or operated Installation sprinklers. Prior to installation, sprinklers should be maintained Model F156 Series sprinklers are standard response sprinklers in the original cartons and packaging until used to minimize the intended for installation as specified in NFPA 13. They must also potential for damage to sprinklers that would cause improper be installed with the Model D Sprinkler Wrench specifically de- operation or non -operation. signed by Reliable for use with these sprinklers. Temperature Ratings The Model F156 Recessed Sprinklers are to be installed with a Sprinkler Max. Ambient Bulb maximum recess of 3 % inch (19mm). The Model Fl, F2, and FP Classification TC p ratur Temp. Color Escutcheon illustrated are the only recessed escutcheon to be Ordinary 57 135 100 °F (38 °C) Orange used with the Model F156 Recessed Sprinklers. The use of any Ordinary 68 155 100 °F (38 °C) Red other recessed escutcheon will void all approvals and negate Intermediate 79 175 150 °F (66 °C) Yellow all warranties. When installing Model F156 Recessed Sprinklers Intermediate 93 200 150 °F (66 °C) Green Highs" 141 286 225 °F (107 °C) Blue use the Model GFR2 Sprinkler Wrench. Any other type of wrench Extra High" 182 360 300 °F (149 °C) Mauve may damage these sprinklers. Not available for recessed Sprinklers. Note: A leak tight 'h" NPT (R1/2) sprinkler pint can be obtained with a torque of8- 18ft- Ibs(10,8- 24,4N -m). Do not tighten sprinklers over maximum recorn- Maximum Working Pressure mended torque. It may cause leakage or impairment of the sprinklers. Glass bulb sprinklers have orange covers to protect the bulb 100 psi ( bar) during the installation process. REMOVE THIS PROTECTION 100% Factory tested hydrostatically to 500 psi (34.5 bar) ONLY AFTER THE SYSTEM HAS BEEN HYDROSTATICALLY Finisho) TESTED AND, WHEN APPLICABLE, THE ESCUTCHEONS Standard Finishes HAVE BEEN INSTALLED. RASCO wrenches are designed to Sprinkler _ Escutcheon install sprinklers when covers are in place. Bronze Brass • Ordering Information Chrome Chrome g Polyester Coated White Painted Specify: Special Application Finishes Sprinkler Model Sprinkler Escutche9n 1. S P Bright Brass Bright Brass 2. Sprinkler Type Black Plated Black Plated 3. Orifice Size Black Paint (3) Black Paint 4. Deflector Type Off White 131 Off White 5. Temperature Rating: Satin Chrome Satin Chrome p g' Lead Plated (3)(4)i+) - Specify when ordering Wax Coated (3)(4)iti(s) - Model F156 Pendent Sprinkler Wax Over Lead (3)(401(8) 6. Sprinkler Finish 1') Other colors and finishes are available on special order. Consult factory for 7. Escutcheon Finish (where applicable) details. Note: When Model F156 Recessed Sprinklers are ordered, the sprin- (3)UL and 3°C) ULC listedsted only n UL and . klers and escutcheons are packaged separately. ( to 200°F (68°C to 93 °C) ratings only. Escutcheon Data (I) 5i 286°F (141 °C) sprinklers may be coated for ambient conditions not exceeding Face of Fitting to 150°F (66°C). peon Approvals Adjustment Dimension Ceiling or Wall ' cULus listed "corrosion resistant" applies to SIN Number RA1325 (Upright) Dimension and RA1314 (Pendent) in standard black or white. F1 1,3,4 Max Recessed 1 (38.1mm) 3 /16 " - 'S /16" 1 " FM Approved finish as " Polyester Coated" applies only to SIN number RA1314 Min Recessed 3 A" (19.1mm) (5m - 24nxn) (Pendent) in standard black or white. F2 1,2,3,4 Max Recessed 1 (38.1mm) 3 /16" - 11 /16" (8) FM Approved finish applies only to SIN number RA1335 & RA1385. Min Recessed 1" (25mm) (5m - 17mm) FP Push-on/ Max Recessed 'he (11mm) 1'/." (38.1mm) Thread -off 1 ' 4 Min Recessed 15 /16" (24mm) 1" (25mm) ( SIN: RA1335 - cULus and FM permits use with Fl or F2 escutcheons for light hazard only. The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Productsmanufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured b The Reliable Automatic Sprinkler Co., Inc. ® Recycled P aper © (800) 4 Sales R eliabi Offices a (800) 848 61051 Sales Fax Revision l i ndicate updated or new data. (914) 829 2042 Corporate Offices www.reliablesprinkler.com Internet Address EG. Printed in U.S.A 02/11 P/N 9999970299 A