Specifications
R JAN 132012 CITY OF TIGAr'D Project Plan: Windmill Apartments Ductless Heat Pump Installation DIVI4i Submitted by: Jonathan Moscatello, The Heat Pump Store - Date: 1/13/12 Address: 10587 SW Tigard St, Tigard, OR 97223 Owners: Jim and Sharon Richards Description: There are 20 identical structures at the property. Each structure is two stories tall, with two apartments on the CITN OF T lower level and two on the upper level. SEE ATTACHED FLOOR Approved .. - [1.--1 ‘AN. Conditionally Approved See Letter to: Follow We will install one ductless heat um s stem (see attached Att.ched [ 1 P P Y Permit NimDer: r - dow ubmittal, Mitsubishi MUZ /MSZ- FE12NA) for each apartment. Add - _ :o' IM':a► By: •`��r. D ate: ,(� hese are split systems, with an indoor "head" and an outdoor heat pump unit. The indoor and outdoor units are connected by BUNDLE containing two small refrigerant lines, OFFICE COPY a power and communications wire, and a condensate drain. 01 Il3 (7) i I' j23 Installation Plan: OUTDOOR HEAT PUMP UNIT: The outdoor heat pump for each unit will be attached to the wall of each structure, just opposite of the storage unit for each apartment, using a manufacturer approved bracket (see BRACKET submittal, see exterior FRONT and BACK photos). The heat pumps will be installed approximately 12 inches above the ground level. They will be supplied with a 230V single phase electric circuit per the manufacturer's specifications using an outdoor disconnect. INDOOR "HEAD ": The indoor "head" unit for each outdoor heat pump will be attached to the living room wall of each apartment (see FLOOR PLAN). It will be connected to the outdoor unit by a so- called "bundle" of refrigerant lines, power /communications wire, and condensation drain line. The "bundle" will travel along the following pathway: from the outdoor unit, the bundle will travel to the nearest foundation vent, and enter into the crawlspace. The bundle will run through the crawlspace and penetrate into the storage unit through the floor. The bundle will run up the wall of the storage unit inside specialized conduit call "line cover ". At about head height, one of the sets of refrigerant lines, one power /communication wore and condensate drain will penetrate the storage unit wall and terminate at the head in the living room. All connections to the "head" will be made. Again the penetration will be sealed with fire caulk. The remainder of the bundle will continue upward toward the second story and the head in the living room of the upper unit. The remaining items in the bundle will penetrate the ceiling of the lower storage unit, enter the upper unit, and continue to the head for the upper unit. Again, connections will be made and penetrations sealed with fire caulk. MITSUBISHI ELECTRIC M If. SUM C O O L I N G & HEATING Split - ductless A/C and Heat Pumps SUBMITTAL DATA: CWMB1.. .... . . .. HEAVY DUTY PAINTED STEEL WALL BRACKETS Job Name: Winmill Apartments Location: Tigard, OR Date: 1/13/12 Purchaser: The Heat Pump Store Engineer: Submitted to: For LReference LApproval ;=!Construction System Designation: Schedule No.: GENERAL FEATURES ASSEMBLY INSTRUCTION • The CWMB1 wall brackets are designed to provide a t Fit the vertical component to the horizontal arm by means to mount the Mr Slim M- Series, S- Series. P- Series inserting two TEM8X90 screws with four lock washers + and CITY MULTI PUMY •Series outdoor units on a suitable tour flat washers + two self - locking nuts into the bracket wall or structure and keep the equipment off the ground components as illustrated The CWMB1 consists of two independently mounted wall brackets to allow proper leveling and support SELF- LOCKiNGI WASHERS WASHERS i 8X99 SCREWS NUTS I • The formed mild carbon steel two piece bracket is a x8 rugged fabricated. heavy duty accessory constructed for t x4 x8 xv i / x4 long reliable service life. The bracket is finished with an electrostatically applied, thermally fused acrylic or polyester powder coating for corrosion protection r r x2 0 • The CWMB1 meets the intent and provides compliance with `Oi a, ` � _ those codes requiring mounting HVAC equipment above ground level c ` = �, , PLEASE NOTE _ , a The Wall Bracket load capacity can only be assured if the _` Installation is carried out properly (see drawing A) Drawing B illustrates an improper installation 2 Make sure the chosen installation location meets with . specified requirements and wall design and construction r--- suitable materials ana and strong hardware enough are the to hold the brackets responsibilityof the and 1 -- . 440 lbs - associated equipment loads Anchors and related mounting IV and installer 3 Avoid mounting the brackets and attached load on weak walls. soft siding, veneer panels. perforated bricks / blocks or othei insufficient mounting surfaces A b It is the responsibility of the Project Engineer and/or the Installing Contractor / Dealer to specify furnish. and install a x b any anchor or attachment materials required for the wall construction at the selected mounting location We are not 20.47" x 15.75" responsible for any installation faults or defects c It is strongly recommended to have the installation periodically inspected by a skilled technician ASSEMBLY Notes: 2011 MITSUBISHI ELECTRIC 8 ELECTRONICS. INC DIMENSIONS: CWMB1 I_ ; ....., t.... ,) d L ... J 4. 1 ' r 1 '•� <�, S I ��---! i � N.,VO,� _ Self tocktnq zinc plate() SAS Gas WI K P� steel nut, white (UM 74741 05010 14) LE. WOO' S. .y,' ) HEAVY DUTY WALL RRACKETS Ar t MITSUBISHI ELECTRIC COOLING & HEATING • PARTNER 'tea. Better 3400 Lawmncevliie Suwanee Rd Suwanee. GA 30024 Tale 678.376 -2900 • Fax 800-889-9904 Toll Free 800- 433 -4822 (03) *woe mehvac mm F ORMN I TSU t - 201108 Specifications are subject to change without notice. 2011 © 2011 MITSUBISHI ELECTRIC & ELECTRON INC MITSUBISHI ELECTRIC Aff MI I(. SLIIM• COOLING & HEATING S plit - ductless A/C and Heat Pumps SUBMITTAL. DATA: MSZ- FE12NA -8 8 MUZ- FE12NA1 12.000 BTU /11 WALL-MOUNTED HEAT PUMP SYSTEM Job Name: Windmill Apartments Location : Tigard, OR Date: 1/13/12 Purchaser: The Heat Pump Store Engineer: Submitted to: For ❑Reference ❑Approval iiConstruction System Designation: Schedule No.: GENERAL FEATURES • Highly energy- efficient system that features 92% heating capacity .irr,- i -..v: t jy rj e :, • at 5`F. 75% at -4 "F, and 58% al -13 F _ • Updated sleek. compact indoor and design • • Includes Standard Platinum Deodorizing. and Anti-allergy En- me filters for complete air purifying zy- " P • ► owerful Mode function permits system to temporanly run at a lower/higher temperature with an increased fan speed. which indoor unit MSZ- F612NA•8 A quickly brings the room to the optimum comfort level • Integrated i -see Sensor automatically adjusts the unit's operation Il i according to temperature differences detected between the floor and the intake air. ensuring optimum comfort and energy usage 1 "'` '" '" • Hand -held Wireless Remote Controller Outdoor Unit MUZ- FE12NAI • Base heater is available as an option • Limited warranty five years on parts and defects and seven years on compressors OPERATING RANGE ) OPTIONAL ACCESSORIES i d0a1 y1' Oi10O0 "" " `� " P Outdoor Unit M° """" 90•F (3 73• ) 08. ref aro we 115•F AM) 08 Base Heater � Mermen erF(19°C)oe,s7•F(14°C)WO 14°F(.10C1DB n Drain Socket (MAC -851 DS) Nronun 4 (zrCf 08,67f (hind As zsr iz4°c) De 854 (trC) W8 Indoor Unit Neae^ 80 twrrnun 704 121°C) 08.60•F (16•, we -134 4-25'Ci DB, -15•F (•2e•C! wt3" ❑ Condensate Pump (S13100 -230; 230V) •• System ans out a -18°F (,28'C) a said too nst« ear, but recants from c4ADut n Replacement Platinum Deodorizing Filter (MAC -308F T) eperaocn and avanaraity Warts at •13°F (.25°C) Li Replacement Anti- allergy Enzyme Filter (MAC- 418FT. MERV 8) Indoor Unit Controller Options MCA .. 1 A o Wireless Remote Controler Kit (MHK1I with Remote Controller Fan Motor . 0.78 EL A. (MRCH1), Wireless Receiver (MIFH1), and cable (MRC1)• Airflow ❑ Setback down to 50 6 F when used with MRCH1 Remote Controller Cooling (Lo - Med - Hi - Powerful) . 162 - 226. 381 -410 Dry CFM ❑ Portable Central Controller (MCCH 1 for use with Wireless Remote 144 - 202 - 350 - 367 Wet CFM Controller Kit MI-K1)° Heating (Lo - Med - Hi - Powerful) . ..166 - 240 - 399 - 420 Dry CFM ❑ Outdoor Air Sensor (MOS1, for use with Remote Controller (MRCH1). Sound Pressure Level Wreless Remote Controller Kit (MHK1) and Portable Central Cooling (Lo - Med - Hi - Powerful) .. 22 - 33 - 43 - 45 dB(A) Controller (MCCH1y Heating (Lo - Med - Hi - Powerful). .. 22 - 33 - 43 - 44 d13(A) Sae S bmete fa rMamanon on each opnon DIMENSIONS UNIT INCHES / MM o Wall- mounted Wired Remote Controller (PAR -21 MAA. req. MAC-3971F) W 31-7/16 / 799 o MA Contact Terminal Interface (MAC- 397lF) D 10-1/8 / 257 o M -NET Control Adapter (MAC- 3991F) H 11.5/8 / 295 o Remote Temperature Sensor (M21 -JKO -307) - o Lockdown Bracket for Hand-held Controller (RCMKP1CB) Weight 27 lbs. / 12 k9 Cooling' External Finish . , .Munsell No. 1.0Y 9.2 / 0.2 Field Drainpipe Size O.D 5 /8" / 15.88 mm Rated Capacity. . .. 12.000 Btu/h Remote Controller . Wireless Minimum Capacity . 2,800 Bluth Outdoor Unit SEER ... . . .... 23.0 Btu/IVW Total Input 930 W Co DC Inverter -driven Twin Rotary Heating at 47° F• Fan Motor . . 0.56 F. A Rated Capacity 13.600 Btufi Sound Pressure Level Minimum Capacity .... . 3.000 Btu/h Cooling . 48 dB(A) HSPF 10.6 Btu/hNV Heating 49 (113 A Total Input 950 W ( } Heating at 1T° F' DIMENSIONS INCHES r MM Rated Capacity 7.900 Btu/h W 31 - 1/2 r 800 Rated Total Input 780 W D 11-1/4 / 286 Maximum Capacity 13.600 Btu/h H 21-5/8 / 549 Maximum Total Input 1 780 W • Rating condmore ( Cooing) . no 80•F (27CI 08. 67°F (19°C) we. Outdoor 95• Weight 80 lbs / 36 kg (24 W 5"C) DB. 75°F (24e External Finish .. Munsell No. 3.OY 7 8 / 1 1 r ag a 1 47°F) Pmor 704 (21.1Q R 1 C1 D8.80PF (WC) WO gtltbor 474 tam ❑B kW W9 9 Type .. R41 OA asa uor I Refrigerant P e "ear's De e 1 1�'C.l❑a, t9�Fkll Refrigerant Pipe Size O.D. Heating at 5° F Gas Side .......... ...... 3/8" / 9 52 mm Maximum Capacity . 12.500 Blu/h Liquid Side . ... 1/4 "/6.35 mm Electrical Requirements Max Refrigerant Pipe Length 65' / 20 m Power Supply 208 r 230V. 1- Phase, 60 Hz Max Refrigerant Pipe Height Difference . . 40• / 12 m Breaker Size . . 15 A Connection Method .... Flared Voltage Indoor - Outdoor S1 -S2 AC 208 / 230V I R Indoor - Outdoor S2 -S3 _ . DC 12 24V Wreless Remote Controller DC 0 2011 MI TSUBISHI ELECTRIC 8 ELECTRONICS, INC DIMENSIONS: MSZ- FEI2NA -8 & MUZ- FE12NA1 1 MSZ -FEI 2NA-8 Unit: inch _ 31 -3/8 _ 7116 X 1 Oblon• hole 7/16 X 13/16 Oblong hole 30-7/8 1/2 2 -1/2 : 7/: :.7 : es - -_ IMI•I - 8 _ =� Installation plate r 1111111=== 1•= 11 AIM■ L f�tl•IMIN= MNtl•�Il.•�i r — — /hi.. I $' indoor unit -1 1 P116 . . Air in Wall hole e2 -9116 10 1 . 1/4 Installation • ate 1. 27 -1/16 - 1. Pi. . I� ss r m „ es _ in Insulation e1-3/6 0.0 f.'2 Ili - - � in i Liquid tine 01/4 19-11/16 (Flared connection 0114) - .._ Air out 1 E Gas line 03/8 16 -15/16 (Flared connection 0318) Drain hose Insulation 01 -1;8 O D Connected part eS8 0.0 MUZ- FE12NA1 Unit: inch v 15-3/4 Oran hole 161.5/8 "A , 3/r to I REQUIRED SPACE Basically upon 4 inch or more _ - without any obstruction ■n front m and on both sides of the unit n A n r i �.= I +3/,t I) 7 0 Air out 4 1+' 9/16 II ',•" 2- 318 .13116 Oval hole 7 , • /51 I !.., �, I `� / n n ' "lor `� + handle IIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIII 29112 '1 i4 11.114 \+ IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII Open two sees of left. 1110111111111111111111111110411M1011 • nyht, or rear side. ' IIIIIIIIIIIIHIIIIIIIIIIIIHIIIIIIIIIIIIII N1 . IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIUI e iIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIINI I illllllllllllllllllllllllllllllllllllllll I _ �I — nmlN 1pnuunuul �} i - boost pipe 114 Mired) Gas pipe .3ared) 19-11/16 J _ , • —�—� /6 h 31-1/2 12 -23/32 623/52 ELECTRIC �...I C ERTIFIED COOLING & HEATING - -- . ..- hr rr 3400 LawrenoenN wa e Sunee Rd GUS ac Suwanee, GA 30024 Tele. 678- 376 -2900 • Fax 800-889-9904 In tertek Tot Free 800.433.4822l#3) www mehvac cam FORM# MSZ- FE12NA -8 - MUZ -FE 12NA 1 - 201108 Specifications are aubisct to changs without notice. O 2011 MITSUBISHI ELECTRIC & ELECTRONICS INC FLOOR PLAN Two Bedrooms with Two Baths Approx. 987 Sq.Ft. + 98 Sq.Ft. Storage & Patio = 1085 S q.Ft. Total Living Space il Bath fil S J 3 ..........\/ Living 2 kil .., Room Bedroom Patio/ Deck .0.8„ ath \\ t Kitchen rin Bedroom Entr) Dining Room ` /\, ° Pli Left Kitchen Floorplan , � Bath a ® Bedroom LI Living ktorage E 0 S P Room �Bard Patio/ �._i=. Deck / L....- Bedroom (i «iD Kitchen . Entry Dining w N • rolF • Room r Right Kitchen Floorplan . 4 , .: • N � 1 y s !0 r j it • i f . :., L I i i , . _.... 11 l \ . 1 '. 1 . : : ' ,, mill " ?' 1 • \ \ . -• . 1 \ • •, 111 111. 1 : g uil i i i i j '; mg i • i . r I 1- r . Z o . _.... . . , CC f BACK ...: JIIV O • 414p, ii aft ir _ _ _ 1 .e.. ■ - - • - - . _ - - - , _ , , _ •',- ■• 7-4.: 1..................... _ -""--.'"".•--..................„..... • OF • ,- . -.. ill 4111111•Sma r 'a -Au 4 " v III .., r . 'VI •i 411.. - - —4.-- - U.: _ ... _ , ,..._. . 1 _ I . I . -' ------- t --... - -• _ .. ......................".,.._ .............–...--.........,............„ ea s,••••••■•••■•••■•••••■■••••......••••T . ....-- ...- www.-...■ ,..........0•11, '.- i 01.1.illi . . ---- ■0111111110tait- , I ''''' all ii..- la ii: ... #111 41."... .. al .'. ..' WM 1111 a: -111111111111111111‘111L I MY 1 - nr All * aamordwiumillinkiiiiiIIMIR , , •. ........ VP laillinc:- • - .