Loading...
Specifications RECEIVED JAN 1 3 2012 CITY OF TIGAF D Project Plan: Windmill Apartments Ductless Heat Pump Installation" J!LDING DIVISION Submitted by: Jonathan Moscatello, The Heat Pump Store Date: 1/13/12 Address: 10587 SW Tigard St, Tigard, OR 97223 Owners: Jim and Sharon Richards Description: There are 20 identical structures at the property. Each structure is two stories tall, with two apartments on the CIT OF T ARD . TJ M lower level and two on the upper level. SEE ATTACHED FLOOR Approved ... . Conditionally Approved [ See Letter to: Follow [ ] We will install one ductless heat pump system (see attached A { ached � _ 4,0• Zsubmittal, Mitsubishi MUZ /MSZ- FE12NA) for each apartment. Permit Nyr� 1 Addre arM are split systems, with an indoor "head" and an By: 111101, Date: 17. 1 outdoor heat pump unit. The indoor and outdoor units are connected by BUNDLE containing two small refrigerant lines, OFFICE COPY a power and communications wire, and a condensate drain. .2 I) 22 _ > 2 > 24— Installation Plan: OUTDOOR HEAT PUMP UNIT: The outdoor heat pump for each unit will be attached to the wall of each structure, just opposite of the storage unit for each apartment, using a manufacturer approved bracket (see BRACKET submittal, see exterior FRONT and BACK photos). The heat pumps will be installed approximately 12 inches above the ground level. They will be supplied with a 230V single phase electric circuit per the manufacturer's specifications using an outdoor disconnect. INDOOR "HEAD ": The indoor "head" unit for each outdoor heat pump will be attached to the living room wall of each apartment (see FLOOR PLAN). It will be connected to the outdoor unit by a so- called "bundle" of refrigerant lines, power /communications wire, and condensation drain line. The "bundle" will travel along the following pathway: from the outdoor unit, the bundle will travel to the nearest foundation vent, and enter into the crawispace. The bundle will run through the crawlspace and penetrate into the storage unit through the floor. The bundle will run up the wall of the storage unit inside specialized conduit call "line cover ". At about head height, one of the sets of refrigerant lines, one power /communication wore and condensate drain will penetrate the storage unit wall and terminate at the head in the living room. All connections to the "head" will be made. Again the penetration will be sealed with fire caulk. The remainder of the bundle will continue upward toward the second story and the head in the living room of the upper unit. The remaining items in the bundle will penetrate the ceiling of the lower storage unit, enter the upper unit, and continue to the head for the upper unit. Again, connections will be made and penetrations sealed with fire caulk. A i MITSUBISHI ELECTRIC MIre SLIIM COOLING & HEATING Split- ductless A/C and Heat Pumps SUBMITTAL DATA: CWMB1.. "" HEAVY DUTY PAINTED STEEL WALL BRACKETS Job Name: Winmill Apartments Location: Tigard, OR Date: 1/13/12 Purchaser: The Heat Pump Store Engineer: Submitted to: For [=)Reference L Approval ElConstruction System Designation: Schedule No.: GENERAL FEATURES ASSEMBLY INSTRUCTION • The CWMB1 wall brackets are designed to provide a 1 Fit the vertical component to the horizontal arm by means to mount the Mr Slim M- Series, S- Series. P- Series inserting two TEM8X90 screws with four lock washers + and CITY MULTI PUMY - Series outdoor units on a suitable four flat washers + two self - locking nuts into the bracket wall or structure and keep the equipment off the ground components as iliusrated The CWMB1 consists of two Independently mounted wall brackets to allow proper leveling and support SELF- LOCKINGI WASHERS WASHERS 8x00 SCREWS NUTS • The formed mild carbon steel two piece bracket is a , pp I rugged. fabricated, heavy duty accessory constructed for xa/� t x� x0 long reliable service life. The bracket is finished with an electrostatically applied, thermally fused acrylic or polyester powder coating for corrosion protection c. x2 • The CWMB1 meets the intent and provides compliance with those codes requiring mounting HVAC equipment above ground level PLEASE NOTE a The Wall Bracket load capacity can only be assured if the installation is carried out properly (see drawing A) Drawing B illustrates an improper installation. 2. Make sure the chosen installation location meets with specified requirements and wall design and construction suitable and strong enough to hold the brackets and associated equipment loads Anchors and related mounting 440 lbs f materials and hardware are the r esponsibikty of the ‘r . � I X IS s installer . 3 Avoid mounting the brackets and attached load on weak walls, oft siding. veneer panels. perforated becks / blocks, or other A nsufficient mounting surfaces h It is the responsibility of the Project Engineer and /or the Installing Contractor / Dealer to specify furnish. and install a x b any anchor or attachment materials required for the wall construction at the selected mounting location We are not 20.47" x 15.75" responsible for any installation faults or defects c It is strongly recommended to have the installation periodically inspected by a skilled technician ASSEMBLY Notes: C 2011 MITSUBISHI ELECTRIC & ELECTRONICS. INC c Y DIMENSIONS: CWMB1 a i� . ...- 40 0 111 ,�. 0 , . %fit: i "� C� ! "po Self taking am paled M8 o: Class 8.8 zinc p5iZsl steel nut. whne 1UN174741 screw. white. T.E. M8x3.54' (rSO40141 T.E. M8n90' r "..4- I r HEAVY DUTY WALL BRACKETS A FAIT'SUBISHI y / j 11'1IC 0 11 COOLING I HEATING PARTNER v Better 3400 Lawrencewlle Suwanee Rd Suwartee. GA 30024 Tele 678.376.2900. Fax 800 - 889 -9904 To Free. B00 -433-4622 (#3) EORMMCWM61- 201108 wwW corn E 2011 MITSUBISHI ELECTRIC 6 ELECTRONICS. INC Specifications are subject to change without notice. atlik ELECTRRISCHI At IT (gnl If. S5 U FA. COOLING & HEATING Split - ductless A/C and Heat Pumps SUBMITTAL DATA: MSZ- FE12NA -8 8 MUZ- FE12NA1 12.000 BTU /H WALL - MOUNTED HEAT PUMP SYSTEM Job Name: Windmill Apartments Location:Tigard, OR Date: 1/13/12 Purchaser: The Heat Pump Store Engineer: Submitted to: For JReference !- ]Approval DConstruction System Designation: Schedule No: GENERAL FEATURES • Highly energy- efficient system that features 92% heating capacity -- _ ._ c -- -•-- - at 5'F. 75% at -4-F. and 58% at -13 F • Updated sleek. compact indoor unit design • Includes Standard. Platinum Deodorizing, and Anti- allergy En- zyme filters for complete air purifying system _ • a -- -- — - � Powerful Mode function permits system to temporanly run at a lower/higher temperature with an increased fan speed. which Indoor Lint MSZ FE I2NA -8 quickly brings the room to the optimum comfort level • Integrated i -see Sensor automatically adjusts the unit's operation according to temperature differences detected between the floor and the intake air, ensunng optimum comfort and energy usage wreri ss Rernare • Hand field Wireless Remote Controller c Outdoor Unt MUZ -FE 12NA1 • Base healer is available as an option • Limited warranty: five years on parts and defects and seven years on compressors OPERATING RANGE OPTIONAL ACCESSORIES Indoor IntakeA 011Ooor Seeks As Temp Outdoor Unit wankel 9o•F (32•C1 °e• 73'r (2301 we 115°F i4a'Ci ore Base Heater (MAC- 640f31 i -U) Minot= err (1a•C;Lna, SrF (u•CI 1441 14°F,. ne o Drain Socket (MAC - 85105) Marrsnua so•F i27°C 08. 87°F cum) wt3 75°F (24 19° 6. a5F (C) we Indoor Unit M�suy MIrrmun 70 C R1•C) 013.117F OM NB - 13•r 1.29'01 08, -15•F ( -28'C) we•• o Condensate Pump (S13100- 230; 230V) •• Sysiem ezr tM a -1$°F Ran to awed exormiar aria, oa recovers tram cutout o Replacement Platinum Deodorizing Filter (MAC- 308FT) age rauce anoautonvxKarty restarts al •i3"Fr ❑ Replacement Anti- allergy Enzyme Filter (MAC-418FT: MERV 8) Indoor Unit Controller Options MCA . 1 A n Wireless Remote Controller Kit (MHK1) with Remote Controller Fan Motor 0.76 F.L A. • (MRCH1). Wireless Receiver (MIFH1). and cable (MRC1)' Airflow Setback down to 50`F when used with MRCH1 Remote Controller Coding (Lo - Med - Hi - Powerful) ... 162 - 226 - 381 -410 Dry CFM - Portable Central Controller (MCCH1: for use with Wireless Remote 144 - 202 - 350 - 367 Wet CFM Controller Kit MHK1)* Hea (Lo - Med - Hi - Powerful) . ..166 - 240 - 399 - 420 Dry CFM Outdoor Air Sensor (MOS1, for use with Remote Controller iMRCH1), Sound Pressure Level l/ fireless Remote Controller Kit (MHK1) and Portable Central Coding (Lo - Med - Hi - Powerful) . 22 - 33 - 43 - 45 dB(A) Controller (MCCH1)' Heating (Lo - Med - Hi - Powerful) 22 - 33 - 43 - 44 dB(A) •ties S,Jxrut»i Mr ,11}, m , eau , ga ❑ Wall- mounted Wired Remote Controller DIMENSIONS UNIT INCHES / MM (PAR- 21MAA. req. MAC- 3971F) W 31.7/18/799 ❑ MA Contact Terminal Interface (MAC- 3971F) D 10.1/8 ❑ M -NET Control Adapter (MAC- 3991F) H 11 -5/8 / 295 ❑ Remote Temperature Sensor (M21 ,1K0-307) - ❑ Lockdown Bracket for Hand -held Controfler (RCMKP1 CB) Weight ... 27 lbs. / 12 kg Cooling' External Finish .... Munsell No. 1.0Y 9.2 / 0.2 Field Drainpipe Size 0.0 5/8" / 15.88 mm Rated Capacity 12.000 Btu/h Remote Controller Wireless Minimum Capacity 2.800 Btu/h EER . 23.0 Blulh/yV Outdoor Unit S SE E! Input. Ill/ W Compressor . . .. DC Inverter - driven Twin Rotary MCA..... A Heating at 47° F• Fan Motor .... , 058 F.L.A. Rated Capacity 13,600 Btu/h Sound Pressure Level Minimum Capacity .. .. 3,000 Btu/h Cooling ..... . .. . ......48 dB(A) HSPF 10.6 Btu/hsW Healing 49 dB(A) Total Input .. . . ...950 W Heating at 17° P DIMENSIONS INCHES / MM Rated Capacity 7900 Btu in/ 31 -1/2 /800 Rated Total Input . . 750 W D 11 -1/4 / 286 Maximum Capacity .. ...... . .... .........13.600 Btu/h H 21 -5/8 / 549 Maximum Total Input 1.780 W • Raing Ca rora (Coding) - indoor 80'F (27•Ct 08.67°F (19 Miaow a5°F Weight .. . . . 80 lbs / 36 kg ism) De. 7YF a4oC)vve External Finish Munsell No 3.0Y 7 8 / 1 1 Meetly aitrFl- haw 70°F I C 08 . 6 gF(/ a ° C)NB.o,mor47 ° Fte°C► OB 43°Fie°CI AB Refrigerant T (Haan-eat 17°F) -rwor 7u•Farg C oe 83•FN (Maar 1»(. ce 1ST (.5°C B Refrigerant Pipe e Size 0.0. RatOA Heating at S' F Gas Side . 3/8" / 9 52 mm Maximum Capacity. .. 12.500 Btu /h Liquid Side..... . . . 1/4" / 6 35 mm Electrical Requirements Max Refrigerant Pipe Length 65 / 20 m Power Supply 208 r 230V. 1- Phase. 60 Hz Max Refrigerant Pipe Height Difference 40' / 12 m Breaker Size 15 A Connection Method Flared Voltage Indoor - Outdoor S1 -S2 AC 208 / 230V nnr ���� Indoor Outdoor S2 -S3 DC 12- 24V I IVA tKI� Wireless Remote Controller .. DC 0 2011 MITSUBISHI ELECTRIC & ELECTRONICS, INC. DIMENSIONS: MSZ- FE12NA -8 & MUZ- FE12NA1 MSZ FEI2NA - 8 Unit: inch ti 31. _L. 7/16 X 1 Oblong hole 7/16 X 13/16 Oblong hole 30 1/2 - - 1n :7. : -1: m �__� 1 - =��) Installation plate - i - - - -I uua■ rz �__�1_6__ IIIII i I E( WI :i maw # Itlt , i .. -11: 1 -116 1 , c Indoor unit Air in Wall hole 02 -9/16 ri_ j , V 1 10.1/8 1/4 Installation •late 1 /1. . FL iirlg 4 m N LII [1 t i rte :_- . r in .1 , Insulation et- 3/80.D 1' a Ls u,d line 0114 19 -11/16 (Flared connection 0114) Air out t 1 E Gas ;ale 03 /8 16 - 15/16 (Flared connection 03/8) Dian nose Insulation el -1/8 0 D Connected part 05/8 0.D i MUZ- FE12NA1 Unit: inch 1 , Drain hole tM -5/8 REQUIRED SPACE Basically open 4 rtct or more 1 _ 1 without any obstruction in front MN and on both sides of the unit 1 A an 4> ) _ . m N. At 0 O >A r � � ... 134740 d Air out 4 't-- -- 0114 {`,. I 2 -318 r13/16Oval hole 7 7/8 � I �ln IIIIIIIIIIlIlII1IIIIIIIIIIIIIIII 29/32 . , 11-114 ! IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII 1 open two sdes of 101 IIIIIIIIIIIIIIII11111IIIIIIIIIIIIIINIII s ' ngnt, or rear side _ IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII N I IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII LIIII llllllllllllllltlllllllllllllllllllllll ! 7 11 IlllflIUhlIIlfIItIlIIIIIIIIIIlIII * .f_ T ____ L. _ / --- . uf. _ _ - L a Lies pipe Liquid pipe 1/4 'flared) 149132 tS 1 &11/16_ + 31.1 — * 2 -23132 I6 MITSUBISHI � aaajjj ��� + ELECTRIC r .ew CERTIFIED. • I rU` COOLING & HEATING PARTNER F Het!e US 3400 Lawrenceville Sunee Rd ` Suva nee eo Suwanee, GA 30024 Tele 678- 376.2900 • Fax 804889-9904 Intertek Tot Free' 804433.4822 (#3) mini mehvac Com FORM* MSZ - FE 12NA-8 - MUZ -F E 12NA 1 - 201108 Specifications are subject to change without notice. 0 2011 MITSUBISHI ELECTRIC b ELECTRONICS INC FLOOR PLAN Two Bedrooms with Two Baths Approx. 987 Sq.Ft. + 98 Sq.Ft. Storage & Patio = 1085 S q.Ft. Total Living Space Bath j r. a n I I 1 Living A W Room n Bedroom Patio / jI Deck C Bath 7 at Kitchen r Entry Dining Room is ' /�,, ' 6 .. / irt Left Kitchen Floorplan n Bath „ X e Storage [i /11 1 Bedroom `n Room t ,1 Bath f Patio/ Deck / Bedroom 1-11"111 Kitchen Encr. •�� Dining • Room Right Kitchen Floorplan M - f... me d.t . ' 4 ..11 '.':,' •:.• 1 '7; . . X I • • ,.. , , . - 1 • .,...! „„, i , 4.. , • . _ i, Ili :., 1 Iii 0111 -.,-, \ , 1 \ 1 \ 1 l . . , .,,_.,1 -1.*.., ,-• •.,;•,..- i 1 :-.....-,...,:' , 1 .._ .... _.. . . i I , ... • , :. III — - - . . . . c 1 i lizIEr . ..., i ll V I 1 ' li II" .,. , .. 1 $ i 1 I ' 71 VI Z • ,.. , . • CC IL 44, U.. . . , • i " ' ..1 . • -.. . . i . . , ... I. fi . . BA CK „ tor . . .. _ . . .. .„. - II • .., lig - . : %IP I. -...... ... F • . . . . ._ -,... . . . . . - , , :., , ,L. .. • , .4'.. ; . ' - - 1... , • ' Iiiiii,, , - 4. , 4•• ________ _ . _ i.. i -. fl .. . . , . .; • ,,-..... . --............... ---...—.....--.._ ..-- . 7* III "111111 ,:: ille . , . Val . . . .,, . Li :, INNIMS•r • 1 , • , . I : . *-.. - ........-w.......................„.,-,.....„ . "11 „ . ' 1ill - f . I ___ . • .. , ....,._. , , .......„„,... ,. 1 .... ag • .. ., ..,......., - Jo .. •.. p , ....r i m , Ai& ' :L. - _._ . . , _ _,....,. , .............. ., .,.. - - . .vrei iiiiiia natistamangsimism• " Iii4.-- . - ' - r ---=` -- — - — 2431114 PIA 4.4 iiilit:4 :leger.t .:-...._ r. 1 01, . -... 7. ' . f ' 7 3 . . _ ... -._ L _ ....