Loading...
Specifications • RECEIVED JAN 1 3 2012 CITY OF TIGA� iD Project Plan: Windmill Apartments Ductless Heat Pump Installat 1NG DIVISION Submitted by: Jonathan Moscatello, The Heat Pump Store Date: 1/13/12 Address: 10587 SW Tigard St, Tigard, OR 97223 Owners: Jim and Sharon Richards Description: There are 20 identical structures at the property. Each structure is two stories tall, with two apartments on the CIT vcAAp lower level and two on the upper level. SEE ATTACHED FLOOR Approved l L to [ t. N Conditionally Approved [ ] See Letter to: Follow [ I We will install one ductless heat pump system (see attached A •ched Permit Numb V E.2.0 Z 001 ' submittal, Mitsubishi MUZ /MSZ- FE12NA) for each apartment. Addr i''1� �,I�i'? ►► p Y These are split systems, with an indoor "head" and an By: .i. t. Date: I t` IZ outdoor heat pump unit. The indoor and outdoor units are connected by BUNDLE containing two small refrigerant lines, OFFICE COPY a power and communications wire, and a condensate drain. Installation Plan: `z 1 1 3 l 3� OUTDOOR HEAT PUMP UNIT: The outdoor heat pump for each unit will be attached to the wall of each structure, just opposite of the storage unit for each apartment, using a manufacturer approved bracket (see BRACKET submittal, see exterior FRONT and BACK photos). The heat pumps will be installed approximately 12 inches above the ground level. They will be supplied with a 230V single phase electric circuit per the manufacturer's specifications using an outdoor disconnect. INDOOR "HEAD ": The indoor "head" unit for each outdoor heat pump will be attached to the living room wall of each apartment (see FLOOR PLAN). It will be connected to the outdoor unit by a so- called "bundle" of refrigerant lines, power /communications wire, and condensation drain line. The "bundle" will travel along the following pathway: from the outdoor unit, the bundle will travel to the nearest foundation vent, and enter into the crawlspace. The bundle will run through the crawlspace and penetrate into the storage unit through the floor. The bundle will run up the wall of the storage unit inside specialized conduit call "line cover ". At about head height, one of the sets of refrigerant lines, one power /communication wore and condensate drain will penetrate the storage unit wall and terminate at the head in the living room. All connections to the "head" will be made. Again the penetration will be sealed with fire caulk. The remainder of the bundle will continue upward toward the second story and the head in the living room of the upper unit. The remaining items in the bundle will penetrate the ceiling of the lower storage unit, enter the upper unit, and continue to the head for the upper unit. Again, connections will be made and penetrations sealed with fire caulk. Ar t MITSUBISHI i, ELECTRIC in If. S �ll(� 1 1 C O O L I N G & HEATING Split- ductless A/C and Heat Pumps SUBMITTAL DATA: C WMB 1 ` HEAVY DUTY PAINTED STEEL WALL BRACKETS Job Name: Winmill Apartments Location: Tigard, OR' I Date: 1/13/12 Purchaser: The Heat Pump Store Engineer: Submitted to: For LijReference LJApproval LjConstruction System Designation: Schedule No.: GENERAL FEATURES ASSEMBLY INSTRUCTION • The CWMB1 wall brackets are designed to provide a 1 Fit the vertical component to the horizontal arm by means to mount the Mr Slim M- Series. S- Series. P- Series inserting two TEM8X90 screws with four lock washers + and CITY MULTI PUMY - Series outdoor units on a suitable four flat washers + two self - locking nuts into the bracket wall or structure and keep the equipment off the ground components as illustrated The CVVMB1 consists of two ;ndependently mounted wall brackets to allow proper leveling and support SELF - LOCKING WASHERS WASHERS 8X90 SCREWS NUTS • The formed mild carbon steel two piece bracket is a x4 E� x8 pp F-7--C rugged. fabricated, heavy duty accessory constructed for X8o x4 long reliable service life. The bracket is finished with an electrostatically applied, thermally fused acrylic or polyester powder coating for corrosion protection gip, to x2 • The CWMB1 meets the Intent and provides compliance with o Y~ those codes requiring mounting HVAC equipment above ground level ,/ _ _ o PLEASE NOTE � _ - a The Wall Bracket load capacity can only be assured if the installation is carried out properly (see drawing Al Drawing B illustrates an improper installation 2 Make sure the chosen installation location meets with specified requirements and wall design and construction is suitable and strong enough to hold the brackets and associated equipment loads Anchors and related mounting 440 lbs ' • materials and hardware are the responsibility of the 'W (— • installer ti U 3 Avoid mounting the brackets and attached load on weak wars, 9 soft siding, veneer panels. perforated bricks/blocks. or other A insufficient mounting surfaces. b It is the responsibility of the Protect Engineer and /or the Installing Contractor / Dealer to specify furnish, and install a x b any anchor or attachment materials required for the wall construction at the selected mounting location We are not 20.47" x 15.75" responsible for any installation faults or defects c It is strongly recommended to have the installation periodically inspected by a skilled technician ASSEMBLY Notes: 02011 MITSUBISHI ELECTRIC 8 ELECTRONICS. INC DIMENSIONS: CWMB1 1 -.95- 0 , f.. Q �'' ;} { �� • i j-. • „ . t :t j .!� 1 .. "r f - - • ` ' v R a y , Self tacking e plated MA . J' Class 89 zinc p al steel - - - - m •nut. Mute tUNi 74741 ' sue” white. I.E. M8x3.54' (1504014) T.E. M8x90' ";� 1 HEAVY DUTY WALL BRACKETS Arti k MITSUBISHI ELECTRIC COOLING & HEATING 1,, e_R t ve Setter 3400 Lawrencen9e Suwanee Rd Suwanee. GA :10024 Tele 678. 376 -2900 . Fax 800.889.9904 Toll Free 800 - 433.4822 1#31 wow mehrac tom F ORMA I TSU t • 20 t t 08 Specifications are subject to change without notice. C 2011 MITSUBISHI ELECTRIC S ELECTRON;CS. INC MITSUBISHI A I It ELECTRIC Mr.SLIIIIII. COOLING & HEATING Split- ductku A/C and Hut Pumps SUBMITTAL DATA: MSZ- FE12NA -8 & MUZ- FE12NA1 12.000 BTU /11 WAI L- MOIINTFD HEAT PUMP SYSTEM Job Name: Windmill Apartments Location: Tigard, OR I Date: 1/13/12 Purchaser: The Heat Pump Store Engineer: Submitted to: For DReference ❑Approval QConstruction System Designation: Schedule No.: GENERAL FEATURES • Highly energy- efficient system that features 92% heating capacity at 5 "F. 75% at -4 "F, and 58% al -13'F • Updated sleek. compact indoor unit design .P. -le aiifiri • Includes Standard, Platinum Deodorizing. and Anti-allergy En- .,__ ....._ zyme filters for a complete air purifying system • Powerful Mode' function permits system to temporarily run at - a lower/higher temperature with an increased fan ed which /ewer u ft MSZ- FE12MA -8 quickly brings the room to the optimum comfort levet • Integrated i -see Sensor automatically adiusls the unit's operation according to temperature differences detected between the floor O and the intake air, ensunng optimum comfort and energy usage Moons Core oiler • Hand -held Wireless Remote Controller - Outdoor lint MUZ FE12NA1 • Base heater is available as an option • Limited warranty: five years on parts and defects and seven years on compressors OPERATING RANGE OPTIONAL ACCESSORIES ndo° "' " T'"'° Cutloo Intake aa Temp Outdoor Unit Kunlu + 90•F (32•C> DB 73•F i23•C1 WB 115°F 146 De Coding Base Heater (MAC - 640131 1 - Mmm >u n7•F t,4° DR sr•F ( vui le. r., 0•C) be Drain Socket (MAC -851 DS) Ma.an xn eo•r 2 ° c > 38 67•F (,tom) nB 75•F (24•C) Ca 6,•r r 1 e•c> we Indoor Unit "' Mrn°nuni 70'F 121•C) De 60•r it6Ci -13•F (- 25'C10e, -15•F i -26'C1 WB• Condensate Pump (S13100 -230, 230V) •• Sruem W., 0,4 al -18•F i -28•CI a r.OKI tierrnata a cr but rfx -cve - s from cutout Replacement Platinum Deodorizing Filter (MAC- 308FT) cpef11vcndna ,nat,caityredansa1•13°Fi -25°C) Replacement Anti- allergy Enzyme Filter (MAC- 418FT: MERV 8) Indoor Unit Controller Options MCA . .... 1 A Wireless Remote Controller Kit (MHK11 with Remote Controller Fan Motor 0.76 F.L A (MRCH1), Wireless Receiver (MIFH1). and cable (MRC1)• Airflow Setback down to 50 "F when used with MRCH1 Remote Controller Cooling (Lo - Med - Hi - Powerful 162 - 226 - 381 -410 Dry CFM -, Portable Central Controller (MCCH1 for use with Wireless Remote 144 - 202 - 350 - 367 Wet CFM Controller Kit MHK1)* Heating (Lo - Med - Hi - Powerful) ....166 - 240 - 399 - 420 Dry CFM Outdoor Air Sensor (MOS1, for use with Remote Controller (MRCH I), Sound Pressure Level Wireless Remote Controller Kit (MHK1) and Portable Central Cooling (Lo - Med - Hi - Powerful) . 22 - 33 - 43 - 45 dB(A) Controller (MCCH1)° Heating (Lo - Med - Hi - Powerful. 22 - 33 - 43 - 44 18(A) See S. bfmt for >nfamutan an earn option DIMENSIONS UNIT INCHES / MM - Wall- mounted Wired Remote Controller (PAR- 21 MAA. req. MAC- 3971F) W 31.7/16/ 799 - . MA Contact Terminal Interface (MAC- 3971F) D 10 - 1/8 / 257 > M -NET Control Adapter (MAC- 3991F) H 11- 5181295 Remote Temperature Sensor (M21 -JKO -307) Lockdown Bracket for Hand -held Controller (RCMKPICB) Weight . ... 27 lbs. / 12 kg Cooling" External Finish . .. . ....Munsell No. 1.OY 9 2 / 0.2 Field Drainpipe Size O.D. .. 5/8" / 15.88 mm Rated Capacity . . 12.000 Btu/h Remote Controller Wireless Minimum Capacity . 2.800 Btu/h Outdoor Unit SEER ... 23.0 BIuRVW Compressor Total Input. 930 W MCA AA essw DC Inverter -driven Twin Rotary .1 Heating at 47° P Fan Motor . 0 56 F.L.A Rated Capacity 13.600 BtuR1 Sound Pressure Level Minimum Capacity 3.000 Btu/h Cooling 48 dB(A) HSPF 10.6 Btu/h1W Heating 49 dB(A) Total Input. . . .. . . .950 W Heating at 17° F• DIMENSIONS INCHES / MM Rated Capacity 7,900 Btu/h W 31-1/2/800 Rated Total Input . ..... 750 W D 11 -1/4 / 286 Maximum Capacity .. .... . .. . 13.600 Btu/h H _21-5/8 / 549 Maximum Total Input . 1.780 W • Rating Condiaone (Cooing) - indoor 80°F ( 2 7 •C I DB 67°F (19°C) VW Outdoor 95°F Weight . ... . ..80 lbs. / 36 kg (35°C) Da. 75 (24°C) we External Finish . . . Munsell No. 3.0Y 7.8 / 1 1 mamma ar47•F).inOzor De. eft v(10 °C)wB OW1or47•F ;MOB 43'F ItrC)wa Refrigerant Type R41OA (Hering a t74I. honor 713°F (21°QDB 110°F {16"C)na Oh xgr tiff on) pe. 15°F(-9'L7 AB Refrigerant Pipe Size O.D. Heating at 5° F Gas Side 3/8" / 9 52 mm Maximum Capacity.. . . 12.500 Btu/h Liquid Side . 1/4° / 6.35 mm Electrical Requirements Max. Refrigerant Pipe Length 65' / 20 m Power Supply ... .. 208 1 230V, 1- Phase, 60 Hz Max Refrigerant Pipe Height Difference . 40' / 12 m Breaker Size .. . . . 15 A Connection Method Flared Voltage Indoor - Outdoor St -52 . .. AC 208 / 230V 11 44 1P t I N p Indoor - Outdoor S2-S3 . .... . .... DC 12 -24V t �/Y CiR R Wireless Remote Controller ... DC © 2011 MITSUBISHI ELECTRIC 6 ELECTRONICS. INC DIMENSIONS: MSZ-FEI 2NA-8 & MUZ- FE12NA1 MSZ- FEI2NA -8 Unit: inch 31 -3/8 _ 7116 X 1 Oblong hole 7/16 X 13/16 Oblong hole 30 -7/8 1/2 2 -1/2 8 -7/: : -7/: as Installation plate ^ I i MM..=..ISM■■■ _ c is m -1/8 . 13 -9/18 1 - Air in Wall hole 02 -9x16 1 Ilt �' Installation r ate 111: 1/4 1 7 -1/16 - 1 I 2-1.1)t---6 /4 m IP /-; N ur n A . _ 1/ Drain hose r , Insulation 01 -3/8 0.0 1' a Liquid line 01(4 19 -11/16 (Flared connection e1/4) -- . Air out 1 . 1. a Gas line 0318 16 -15/16 (Flared connection 03/8) Drain hose Insulation 01-1/8 0 D Connected par 05/8 0 0 MUZ- FE12NA1 Unit: inch o + 19.3/4 - — -- ._ —..� Dram hole 01.518 ��,n REQUIRED SPACE Basically open 4 arch or more X _ie— # without any obstruction .n front A r r - -_ „t and on both an sties of the unit :1__ - - 7 I A. r� '1f - 1 - 'I,a '� __ � ,„„,„„„„, 1.9116 • I O Air out ll Z 1!8 1- 318 .13!16 Oval hole I!I t 7 hBr-die ' 1 29!32 11.114 �_ IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII 7 i r Open two sides of left III IIIIIIII (III (III 111111 IIIIIIIIII (III ( — nght, or rear side. l IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII , ec { 111111! IIIIIIIillllllllllllllllllllllll — IIIIIIIIIIIIIIIIIl111111 111111IIIIIIIB V IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIlllllllll 4 . � - --1 111111 immi111flIflmiimmili ni 8 - — L pipe -174 (flared) ss pipe .3/8 (flared) tyt. 1411716 i 31-1/2 , + 2 -23/32 6.23132 A& MITSUBISHI ELECTRIC e°I CERTIFILIJ COOLING & HEATING US 3400 Lawrenceville Suwanee Rd cameo Suwanee, GA 30024 ntertek Tele 678- 376 -2900' Fax 800-889-9904 Toll Free 800-433-4822 (f13) www mehvac con FORMS MSZ -FE 12NA -8 - MUZ - FE 12NA I - 201108 Specifications are subject to change without notla. 0 2011 MITSUBISHI ELECTRIC & ELECTRONICS INC FLOOR PLAN Two Bedrooms with Two Baths Approx. 987 Sq.Ft. + 98 Sq.Ft. Storage & Patio = 1085 S_ q.Ft. Total Living Space 0 ,r O Bath Q Storage , I e if � r / Living A rj Room Bedroom Patio/ Deck II each r l e\ _.i Kitchen =0 Bedroom Entry — Dining Room if F r/ \ A ° f PI, Left Kitchen Floorplan T I; LI V I fl I I Bath ® Bedroom 0 J v V Room death Patio/ iNo I ` Deck I _ Bedroom I D CE Kitchen -- Entry •■■ ^ Dining l w, , *e Room r Right Kitchen Floorplan i . FRONT • g . . ... ^'�^ - V ;+ .�� ^^°.�... -� ,e - - - -.-, _ - - - • _ '..______ . . ...„. ... -, , ,._,... _. _ r .._.... ..._ .....,_ ....... , ___ ,..............._ , ..... r........_____......,,,....... ..... ,___,....... ..�� ` .._.r 4 _ -_ . • • BACK tor, .• it • I ... 4 4.0. ._ .. _ P • _ __. • .._ _ .. . „ i . . , .... . • • -........ , „.. , .. 4 ... l ' • . - I. 2. .--. .,„. •-• . •, 'Et - - • • .„, ,.. .:. r-• --....................,.......... , • : 4 • . . , ..............., ..._..._ . ., • _. ..„ . _ _ _ . . • . .... -Iimmignorpv. It Ake. • . , . .. . , . . . .. . ... 1 , 4 . • I ,"•Vr- •.r . 1..... .., , iiA.....,........................._ Aka ,:f Illatall& =• -.. . - 4, I .,"--;7, --- • - '''' * .1 yown........... .......1101./..illo ,..v. ........................., . . -..... . — ......... I . . - - 1 - .............- , ..... .... , ..._ . , - , 1 _, ....._ .... ......... .:, i .. .-- • 1 t i • I __...... i . .... : • .. /I 1 - IP -,o.., It ^ . amok _ - • IlialaiNraiommimin 411141 C. ' : = 0. hars111 mem ,.... - 11111111111111111k .m, : ' la . , • -- . '.. . ._.• . ... , . .. ... . - • .. . . . ..... . .