Loading...
Specifications R Ec ; '11T r JAN 1 32012 CITY OF TIGARD Project Plan: Windmill Apartments Ductless Heat Pump Installation DIVISION Submitted by: Jonathan Moscatello, The Heat Pump Store Date: 1/13/12 Address: 10587 SW Tigard St, Tigard, OR 97223 Owners: Jim and Sharon Richards Description: There are 20 identical structures at the property. Each structure is two stories tall, with two apartments on the CITY OF WARD CARD lower level and two on the upper level. SEE ATTACHED FLOOR Approved _..ttt . [ AN Conditionally Approved [ ] See Letter to: Follow [ 1 We will install one ductless heat pump system (see attached Att.ched Permit NI. tribe ' submittal, Mitsubishi MUZ /MSZ- FE12NA) for each apartment. Ade • •s: 4 A ► These are split systems, with an indoor "head" and an By: KM Date :' outdoor heat pump unit. The indoor and outdoor units are connected by BUNDLE containing two small refrigerant lines, OFFICE COPY a power and communications wire, and a condensate drain. Installation Plan: , ��, OUTDOOR HEAT PUMP UNIT: The outdoor heat pump for each unit will be attached to the wall of each structure, just opposite of the storage unit for each apartment, using a manufacturer approved bracket (see BRACKET submittal, see exterior FRONT and BACK photos). The heat pumps will be installed approximately 12 inches above the ground level. They will be supplied with a 230V single phase electric circuit per the manufacturer's specifications using an outdoor disconnect. INDOOR "HEAD ": The indoor "head" unit for each outdoor heat pump will be attached to the living room wall of each apartment (see FLOOR PLAN). It will be connected to the outdoor unit by a so- called "bundle" of refrigerant lines, power /communications wire, and condensation drain line. The "bundle" will travel along the following pathway: from the outdoor unit, the bundle will travel to the nearest foundation vent, and enter into the crawlspace. The bundle will run through the crawlspace and penetrate into the storage unit through the floor. The bundle will run up the wall of the storage unit inside specialized conduit call "line cover ". At about head height, one of the sets of refrigerant lines, one power /communication wore and condensate drain will penetrate the storage unit wall and terminate at the head in the living room. All connections to the "head" will be made. Again the penetration will be sealed with fire caulk. The remainder of the bundle will continue upward toward the second story and the head in the living room of the upper unit. The remaining items in the bundle will penetrate the ceiling of the lower storage unit, enter the upper unit, and continue to the head for the upper unit. Again, connections will be made and penetrations sealed with fire caulk. MITSUBISHI /IL ELECTRIC COOLING & HEATING Split -ductless A/C and Heat Pumps SUBMITTAL DATA: CWMB1 HEAVY DUTY PAINTED STEEL WALL BRACKETS Job Name: Winmill Apartments Location: Tigard, OR' 1 Date:1/13/12 Purchaser: The Heat Pump Store Engineer: Submitted to: For DReference LApproval Construction System Designation: Schedule No.: GENERAL FEATURES ASSEMBLY INSTRUCTION • The CWMS1 wall brackets are designed to provide a 1 Fit the vertical component to the horizontal arm by means to mount the Mr Slim M- Series. S -Ser es. P- Series inserting two TEM8X90 screws with four lock washers + and CITY MULTI PUMY- Series outdoor units on a suitable four flat washers + two self - locking nuts into the bracket wall or structure and keep the equipment off the ground components as illustrated The CWMB1 consists of two independently mounted wall brackets to allow proper leveling and support SELF-LOCKING WASHERS WASHERS ! 8X90 SCREWS NUTS I !!!t • The formed mild carbon steel two piece bracket is a r x 4 Q x8 x8 I t � � x4 rugged fabricated, heavy duty accessory constructed for long reliable service life. The bracket is finished with an electrostatically applied, thermally fused acrylic or polyester powder coating for corrosion protection x2 • The CWMB1 meets the intent and provides compliance with ° j o• those codes requiring mounting HVAC equipment above ground level - PLEASE NOTE __ and - -- j a The Wall Bracket load capacity can only be assured if the installation is carried out properly (see drawing AI Drawing B • illustrates an Improper installation 2. Make sure the chosen installation location meets with specified requirements and wall design and construction is suitable and stron enou to hold the brackets and ass equipment loads Anchors and related mounting • 440 Ibs L mat and hardware are the responsibilit of the installer 3 Avoid mounting the brackets and attached load on weak walls, soft siding, veneer panels, perforated bricks / blocks. or other A insufficient mounting surfaces. h It is the responsibility of the Project Engineer and /or the Installing Contractor / Dealer to specify furnish. and install a z b any anchor or attachment materials required for the wall construction at the selected mounting location We are not 20.47" x 15.75" responsible for any installation faults or defects C It is strongly recommended to have the installation periodically inspected by a skilled technician ASSEMBLY Notes: cr2011 MITSUBISHI ELECTRIC & ELECTRONICS. INC DIMENSIONS: CWMB1 libl - 10 2 I: I E st ` 4. . " , �0.�, Self lockmq rim plated Me .1 /r Class &8 tine p YT steel nut. white 1UN1 Yrerv, *Use. T.E. tl16ir3.54' „,--' (150401411.E. whew °ti .l . , l HEAVY DUTY WALL BRACKETS All k MITSUBISHI ELECTRIC COOLING & HEATING PARTNER . r. nt- rter 3400 Lawrencewde Suwanee Rd Suwanee, GA 30024 Tele 678 - 376 -2900. Fax 800-889-9904 Tot Free: 800-433-4822 (#3) FORM# C.WME8 t • 201108 YAW/ mehvaocom 51 2011 MITSUBISHI ELECTRIC a ELECTRONICS. INC Specifications Mt wbjK tto d1aTlyewIthout nods. • MITSUBISHI MIL ELECTRIC Airy 1AM If. SLIM. COOLING & HEATING S plit - ductless A/C and Neat Pumps SUBMITTAL DATA: MSZ- FEI2NA -8 & MUZ- FE12NA1 12.000 BTU;H WAI t - MOIINTFD HEAT PUMP SYSTEM Job Name: Windmill Apartments Location: Tigard, OR I Date: 1/13/12 Purchaser: The Heat Pump Store Engineer: Submitted to: For EReference ❑Approval (Construction System Designation: Schedule No.: GENERAL FEATURES • Highly energy - efficient system that features 92% heating capacity at 5T. 75% at -4 "F, and 58% at -13'F ' • Updated sleek, compact indoor unit design • Includes Standard. Platinum Deodorizing, and Anti - allergy En- 1 ,•.r..�_ fa; zyme filters for a complete air purifying system • "Powerful Mode function permits system to temporanly run at a lower/higher temperature with an increased fan speed. which mow Ur„t MSZ- FEI2NA -8 quickly bungs the room to the optimum comfort level ; • Integrated i -see Sensor automatically adjusts the unit's operation • according to temperature differences detected between the floor and the intake air. ensunng optimum comfort and energy usage . . wuo C • Hand - held Wireless Remote Controller - -- - - 0 Outdoor Oat MU2 - FE 12NAt • Base healer is available as an option • Limited warranty: five years on parts and defects and seven years on compressors OPERATING RANGE OPTIONAL ACCESSORIES " """'"" Tiny aioco ir.w Outdoor Unit r•tawman 90•F (32 06 73•F (23•C) A9 115°F t46•Ci De Base Heater (MAC - 64061 i -U) Coney st•,., „m 67•F 09°C, DB. s?•c i14•C 'AG 14°F (•10.C1 DB Drain Socket (MAC -851 DS) Ma•mun 80•F 12 c7F ( 75°F (24•C) DB. 135°F 116"CI wC Indoor Unit 1./... Aurvmun 70•F OM) DB. 60•F I. i e .13•• 1 -25•C) Da, -15•F (.2t CI We•' • Condensate Pump (513100- 230; 230V) ” System ors out a -18 ( -26 to avau it*n 5ta era. out MOWS tern a,lan Replacement Platinum Deodorizing Filter (MAC- 308FT) uperahe•nano a•sama ttatir restarts at .13'F 1-25 • Replacement Anti- allergy Enzyme Filter (MAC- 418FT: MERV 8) Indoor Unit Controller Options MCA . 1 A Wireless Remote Controller Kit (MHK1) with Remote Controller Fan Motor 0.78 F.L A (MRCH1). Wireless Receiver (MIFH1). and cable (MRC 1)' Airflow . Setback down to 50 "F when used with MRCH1 Remote Controller Cooling (Lo - Med - Hi - Powerful) . . 162 - 226 - 381 - 410 Dry CFM Portable Central Controller (MCCH 1 for use with Wireless Remote 144 - 202 - 350 - 367 Wet CFM Controller Kit MHK1)* Healing (Lo - Med - Hi - Powerful) . ..166 - 240 - 399 - 420 Dry CFM J Outdoor Air Sensor (MOS1; for use with Remote Controller (MRCH1), Sound Pressure Level Wireless Remote Controller Kit (MHK1) and Portable Central Cooling (Lo - Med - Hi - Powerful) . 22 - 33 - 43 • 45 dB(A) Controller (MCCH1)' Heating (Lo - Med - Hi - Powerful). 22 - 33 - 43 - 44 dB(A) 'See Submits) tor uronnaion on each op,o DIMENSIONS UNIT INCHES / MM . Wall-mounted Wired Remote Controller (PAR -21 MAA. req. MAC-3971F) W 31-7116 / 799 . MA Contact Terminal Interface (MAC- 3971F) 0 10.1/8 1257 M -NET Control Adapter (MAC- 3991F) H 11 -5/8 / 295 Remote Temperature Sensor (M21 -JKO -307) Lockdown Bracket for Hand -held Controller (RCMKPICB) Weight 27 lbs. 1 12 kg Cooling* External Finish .. . _ ... .. .. .Munsell No. 1.0Y 9 2 / 0.2 Field Drainpipe Size O.O.. 5/8" / 15,88 mm Rated Capacity . . .. . 12.000 Btu /h Remote Controller Wireless Minimum Capacity . 2.800 Btu /h Outdoor Unit SEER ... 23.0 BIu/hNV Total Input 930 W Compressor DC Inverter - driven Twin Rotary Heating at 47° F• Fan Motor . .. 0 56 F.L A Rated Capacity ..... 13.600 Btu/h Sound Pressure Level Minimum Capacity 3.000 Btu/h Cooling 48 dB(A) HSPF 10.6 Btu/h/W Heating 49 dB(A) Total Input ... . ...950 W Heating at 17° P DIMENSIONS INCHES / MM Rated Capacity 7.900 Bluth W 31.1/2 / 800 Rated Total Input 750 W D 11 - 1/4 / 286 Maximum Capacity 13,600 B&Wh H _21 / 549 Maximum Total Input 1 780 W • Rang Combat* ( cmrsgl Indoor 8C M(z7 Weight . . . .80 lbs. / 36 k g (36•CI08.75•F External Finish .. . . .. Munsell No. 3.0Y 7 8 / 1 1 a 7 o•F R > ° QQ Daae f (1s c C)we(MazerI' (- )08.155'F(.4t) Refrigerant Type i R410A Refrigerant Pipe Size O.D. Heating at 5° F Gas Side .. 3/8" / 9 52 mm Maximum Capacity ... 12.500 Btu/h Liquid Side . 1/4" / 6.35 mm Electrical Requirements Max. Refrigerant Pipe Length.. 65' / 20 m Power Supply 208 / 230V. 1- Phase, 60 Hz Max. Refrigerant Pipe Height Difference 40' / 12 m Breaker Size ........ . . .15 A Connection Method Flared Voltage /� Indoor - Outdoor S1 -S2 .. AC 208 / 230V fl I p p Indoor - Outdoor S2 -S3 . .. DC 12 -24V `' Wireless Remote Controller DC O 2011 MITSUBISHI ELECTRIC & ELECTRONICS, INC. DIMENSIONS: MSZ- FE12NA -8 & MUZ- FE12NA1 MSZ- FE12NA -8 Unit: inch 31-3/8 __ 7/16 X 1 (Won. hole 7/16 X 13/16 Oblong hole 1/2 2 -1/2 : -7/: :•7/ ao Installation plate - 1• a . , t: . 1943043L16111 114 13.9/16 1 ' Air in Wall hole 02 -9/16 V 1 1/8 1U Installation date - 1 27 -1/16 - 3/16 Pig" • - 1/1. T ua co r \ I "/ N O , ' , Maim - . 1- t/ _ fin o Insulation el -3/8 0.0 e - - 1 1. a Liquid line 01/4 19 -11/16 (Flared connection e1 /4) Air out a Gas line o3/8 16.15/16 (Flared connection 03/8) Drain hose Insulation e1 -118 0.0 Connected part e5/8 0.0 MUZ- FE12NA1 Unit: inch 15-3/4 Drain hole 01 -5 /a el__ 0 Par in REQUIRED SPAC i Basically open 4 inch of more without any obstruction .n front A 4 and on both sides of the unit Air a1 ; ef ~ I. lio titil 1 1 1 -9116 me Air out i^— ? Je'4 0, i 29132 11 -114 Ire 2- 3/8 ,, 13/16 Oval hole 1 4 � , t II111111111111111111111111111111111111111 ��� uiuiiiiiiiuuiiiiuiiiimuiiiim l Open Iwo Odes\ll 11111111111111111111111111111111111111 III _ � nynl, of rear sale IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII 1 011111110111111111111111111111111111 N I 0, iuiiuiiiiiiiuuiiiuuiiimaiiui I 1111111111111111111111111111011111111 i 1111111111111111111111111111111111111111 iy P li .t - -�. — - - -- — A —�._ 2Br�? -- — L... pipe ,;4 (flared) 4 - Gas pipe 3,8 glared) 151 1411/16 s. . __ 31-1/2 2 -23132 62342 * Jff CERTtFIEO• COOLING & HEATI , . . .. PARTNER hr- „ r. .... US 3400 Lawrenceville &manse Rd " "` O Suwanee, GA 30024 n tertek Tote 678-376.2900 • Fax 800-889-9904 Toll Free 800.433-4822 YAW/ mehvac com FORMO MS$ZZ FE12NA -8 - MUZ -F E 12NA 1 - 201108 Specifications are subject to change without notice. O 2011 MirsUBISHI ELECTRIC & ELECTRONICS INC FLOOR PLAN Two Bedrooms with Two Baths Approx. 987 Sq.Ft. + 98 Sq.Ft. Storage & Patio = 1085 Sq.Ft. Total Living Space Bath r I r Iage ,d �I ® r Living II LA Room n Bedroom 4. Patio/ Deck Bath Kitchen 0 Bedroom Dining Entry Room !•r! / A x CM Left Kitchen Floorplan n _ Bath ® j _/ -- a tors :e a Bedroom Q Living �� V Room , � A stb Patio/ Deck iL Bedroom 10 c.4 Kitchen Ent r%• " I . Dining Room Right Kitchen Floorplan co FRONT F.�.� +•-- -• W . . '': ' k : 4 'ice ?.:f . '_' • k LE T. - - ------"-- , 4.-- --------.1,--- r „ - ci . "filial . __ i - - -- - ,d. . • . ILL . ,. i • BACK , N • a M. I 1 * -4... 4 14 • 4 . Nr„ .t. ...... .44. -.4 ' • . ' • P. ..,. S . , . .. , . ... . 4 .' :"'. . '; ;1.. - L: - .. .,.-. - • •, .,.. . ... - -..... ......,... ...- ■ ._ . _ ' ' • * ._ Iii •••••--... . ____...... ,_. . ......................_._ --.... : 1 - 1- 1 t."--,•■..—„..................,........, . ' * PIE , • %ir t . : , . ...., ,......,...,..,......,. 41111111.ft.r. va lira . , ' 70 1/ VIP ., It . , .., • • t . ._...t..6...„, . . . , • .... , ... . - . . . • . . . .._ ,. ... . . , •••••■•.......• ..•••••■aky...w.,•■■••••-.1.•111...- 1 . ' I I IC_ • ............_ . .., taw .. • . t... . • ...... ... 416 • ..........: ' : , ■ ..- . . . . 4 1 ... . , . . t • . ..•.. . ' artaammein •—........... /I "477 ft IN AS alaittaiiiIK osfaim 1 - aaliaiit ..;.. ,4' -';A, ! .1'.. 1.:..41% • . - .... . Calli ansine aria . z.: ,...4....... z. 1416-0;4ak., Mir' I ---- 11113/1110 AO . .., : .1111 41.11111MIL in' EM- , . • . . • .. , . . ....wk... - . . .