Loading...
Specifications • I .. .. .. • • • • .. RE CEIVED Project Plan: Windmill Apartmeflts.IDuctless beat Fwm JAN 3 2012 • .. • . • • OF TIG Submitted by: Jonathan Moscatello, l'lie Heat ump Siore BUILDING DIVISION Date: 1/13/12 .. • .. • ...... Address: 10587 SW Tigard St, Tigard, OR 97223 Owners: Jim and Sharon Richards Description: There are 20 identical structures at the property. Each structure is two stories tall, with two apartments on the lower level and two on the upper level. SEE ATTACHED FLOOR Approved 4 Conditionally Approved [ 1 See Letter to: Follow [ We will install one ductless heat pump system (see attached Att.ched permit Nim.e • z doI 40i . , submittal, Mitsubishi MUZ /MSZ- FE12NA) for each apartment. Addr 40 ■ 0 ' ?:3s • These are split systems, with an indoor "head" and an By: Aria. Date: outdoor heat pump unit. The indoor and outdoor units are connected by BUNDLE containing two small refrigerant lines, OFFICE COPY a power and communications wire, and a condensate drain. Installation Plan: 37) -s ) OUTDOOR HEAT PUMP UNIT: The outdoor heat pump for each unit will be attached to the wall of each structure, just opposite of the storage unit for each apartment, using a manufacturer approved bracket (see BRACKET submittal, see exterior FRONT and BACK photos). The heat pumps will be installed approximately 12 inches above the ground level. They will be supplied with a 230V single phase electric circuit per the manufacturer's specifications using an outdoor disconnect. • . • •• •• • • • • • • • • • . .... • .. .. • .. • • • •. • • • • • • • • • • • • • • • • • • • • • • • • • •• •• • • • • • • • • • • • • • • • • • • • • • • •• • • • • • •• ••• • • • ••• INDOOR "HEAD ": The i ndoor "head" unit for each outdoor heat pump will be attacf►eil• o e;lkyigg wall of each • apartment (see FLOOR KL�CN .1tLv1fl.blk 4onnected to the • ••• • ...... outdoor unit by a so- called "bundle" of refrigerant lines, power /communications wire, and condensation drain line. The "bundle" will travel along the following pathway: from the outdoor unit, the bundle will travel to the nearest foundation vent, and enter into the crawlspace. The bundle will run through the crawlspace and penetrate into the storage unit through the floor. The bundle will run up the wall of the storage unit inside specialized conduit call "line cover ". At about head height, one of the sets of refrigerant lines, one power /communication wore and condensate drain will penetrate the storage unit wall and terminate at the head in the living room. All connections to the "head" will be made. Again the penetration will be sealed with fire caulk. The remainder of the bundle will continue upward toward the second story and the head in the living room of the upper unit. The remaining items in the bundle will penetrate the ceiling of the lower storage unit, enter the upper unit, and continue to the head for the upper unit. Again, connections will be made and penetrations sealed with fire caulk. • •• •• •• • • • • •• • • • • • • • • • • • • • • • • • • • • •• •• • • • • • • • • • • • • • • • • • • • • • • • • MITSUBISHI • • ' • • • • • ' • •• AAik ELECTRIC . • . • • Mir.SUM. O O L I N G G & HEATING • • • • • • • • • • • • • • ' Split - ductless A/C and Heat Pumps SUBMITTAL DATA: CWMB1...... HEAVY DUTY PAINTED STEEL WALL BRACKETS Job Name: Winmill Apartments Location: Tigard, OR' I Date: 1/13/12 Purchaser:The Heat Pump Store rlgifieer *e •• Submitted to: • F• • •� • ee ege c A 'Construction • • Pl Ceh C .'�, pP roval System Designation: Schedule No.: GENERAL FEATURES ASSEMBLY INSTRUCTION • The CWMB1 wall brackets are designed to provide a 1 Fit the vertical component to the honzontal arm by means to mount the Mr Slim M- Senes. S- Series. P- Series inserting two TEM8X90 screws with four rock washers + and CITY MULTI PUMY - Series outdoor units on a suitable four flat washers + two self - locking nuts into the bracket wall or structure and keep the equipment off the ground components as illustrated The CWMB1 consists of two independently mounted wall brackets to allow proper leveling and support SELF 1 WASHERS WASHERS ! 8X90 SCREWS NUTS • The formed mild carbon steel two piece bracket is a rugged fabricated, heavy duty accessory constructed for x4 I'D x8 @ x8 : x4 long reliable service life. The bracket is finished with an -- electrostatically applied, thermally fused acrylic or polyester powder coating for corrosion protection o, ro x2 • The CWMB1 meets the intent and provides compliance with '4.10 r, I those codes requiring mounting HVAC equipment above ground level �_--- o PLEASE NOTE __ - -,� a The Wall Bracket load capacity can only be assured if the installation is carried out properly (see drawing Al Drawing B illustrates an improper installation 2 Make sure the chosen installation location meets with . specified requirements and wall design and construction is suitable and strong enough to hold the brackets arid associated equipment loads Anchors and related mounting 440 lbS materials and hardware are the responsibility of the • - installer 3 Avoid amounting the brackets and attached load on weak walls. B soft siding, veneer panels. perforated bricks / blocks. or other A insufficient mounting surfaces. h It is the responsibility of the Project Engineer and/or the Installing Contractor / Dealer to specify furnish, and install a a b any anchor or attachment materials required for the wall construction at the selected mounting location We are not 20.47" x 15.75" responsible for any installation faults or defects c It is strongly recommended to have the installation periodically inspected by a skilled technician ASSEMBLY Notes: C 2011 MITSUBISHI ELECTRIC & ELECTRONICS. INC • • • • • •• • • • • •• • • • • • • • • • • • • • • • • • • • • • • • • • • •• • •• • • • • • • • • • • • • • DIMENSiONS: CWMB1 . . • • • • • •• •• • • • •• • • • • • • • • • • • • • • •• • • •• • • • • ,• • •• • • • • • e •• ••• • ••• ••• r 1 i • •,••• • •• •• • • • •S• • • • • • 0 • I • ••• •• • • • •• ` 4. • • •• • , I ) I I . / i . i% - 0 s i r tit '� f 1 0,,. Self locking zinc .••• J t Class B8 zinc p cI steel ��: - nut. volute (LIM7477 • screw. Mute. T.E. MBK3.54' (nSO40141 T.E. M8s90' / r HEAVY DUTY WALL BRACKETS 0 Ar t M COOLING & HEATING 1_ , t,re Better 3400 Lawrenceville Suwanee Rd Suwanee. GA 30024 Tele 678 - 376-2900. Fax 800-889-9904 Tol Free 800 -433 - 4822 (#3) www mehvac cam FORM# I TS U BI . 201108 Specifications are subject to change without notice. ©2011 MITSUBISHI ELECTRIC & ELECTRONICS. INC • •. .. • • • • • •. • • • • • • . • • . • • • • . • • • . • . • • • • • •• • • • • • • AlIt •.• • . • . •.. • • • . • • . • MITSUBISHI ... • .. • • • • • cTr�c mkSUlF • COOLING & HEATING • • • • • •• • • • • • • • Split - ductless A/C and • Heat Pumps SUBMITTAL DATA: MSZ- FE12NA -8 & MUZ- E12tJA1 12.000 BT,.))H WA! t - MOUNTED HEAT PUMP SYSTEM Job Name: Windmill Apartments Location: Tigard, OR I Date: 1/13/12 Purchaser: The Heat Pump Store • _ill girZeer: • •• ••- Submitted to: • F •,Xi frrenr ,,Approval i Construction System Designation: Schedule No.: GENERAL FEATURES • Highly energy - efficient system that features 92% heating capacity ., .. at 5'"F. 75% at -4•'F, and 58% at -13 F • Updated sleek, ,r..•°._.:•.. compact indoor unit design i • Includes Standard, Platinum Deodorizing- and Anti- allergy En- zyme fillers for a complete air purifying system • Powerful Mode• function permits system to temporanly run at a lower/higher temperature with an increased fan speed, which Ineooruni MS - FE12NA2 quickly brings the room to the optimum comfort level • Integrated i -see Sensor automatically adiusts the unit's operation according to temperature d detected between the floor O and the intake air. ensunng optimum comfort and energy usage Means • Hand -held Wireless Remote Controller Outdoor UM Mug FE12NA1 • Base heater is available as an option • Limited warranty: five years on parts and defects and seven FtATI RANGE years on compressors " OPTIONAL ACCESSORIES '°° 'a ""'"' s"'° Ou1000 "'" "°T0 "P Outdoor Unit Maeemen 90° 132•Ci DO. 73°F (23C) NB 115°F i46•Ci DB coaeq Base Healer (MAC - 640D1 i - M.n.mum erF (19°C.) ire. 97°F 114°c) N4i 14°F i •0•c1 08 Drain Socket (MAC- 851DS) lAanrni.el ec r i27 87°F risrC) 'AS 75•F 424°C) DB. 65°F (1e^c) N13 Indoor Unit H•rMn Mmmwm 70°F i21°C) De. 60 i 16CI NO 134' f -25•C) DB, •15°F (26°Ci MB•' Condensate Pump (S13100 -230, 230V) •' system cuticula .16•F { -28°C) to a°roiO led arm tali recovers from Cyit0iJt Replacement Platinum Deodorizing Filter ( MAC- 308FT) oaeratalana r Intent at • 1s°Fi.25°C1 Replacement Anti - allergy Enzyme Filter (MAC- 418FT. MERV 8) Indoor Unit Controller Options MCA . . 1 A Wireless Remote Controller Kit (MHKII with Remote Controller Fan Motor 0.76 F.L A (MRCH1), Wireless Receiver (MIFH1). and cable (MRC1)• Airflow Setback down to 50 "F when used with MRCH1 Remote Controller Coding (Lo - Med - Hi • Powerful) 162 - 226 - 381 • 410 Dry CFM r. Portable Central Controller (MCCH 1 for use with Wireless Remote 144 - 202 - 350 - 367 Wet CFM Controller Kit MHK 1)• Heating (Lo - Med - Hi - Powerful) 166 240 - 399 - 420 Dry CFM Outdoor Air Sensor (MOS1, for use with Remote Controller (MRCH1). Sound Pressure Level Wireless Remote Controller Kit (MHK1) and Portable Central Cooling (Lo - Med • Hi - Powerful) . 22 - 33 - 43 . 45 dB(A) Controller (MCCH1)• Heating (Lo - Med • Hi - Powerful). 22 - 33 - 43 - 44 dB(A) 'See Subnvttal for reonnetionn on each ap•on DIMENSIONS UNIT INCHES / MM ., Wall- mounted Wired Remote Controller (PAR- 21MAA. req. MAC- 3971F) W 31 - 7/16 r 799 MA Contact Terminal Interface (MAC- 3971F) D 10 - 118 / 257 M -NET Control Adapter (MAC- 3991F) H 11-5/8 / 295 Remote Temperature Sensor (M21- JKO•307) Lockdown Bracket for Hand -held Controller (RCMKP1CB) Weight . .. 27 lbs. / 12 kg External Finish .. .Munsell No 1.0Y 9 2 / 0.2 Cooling* Field Drainpipe Size 0.0. . .. . 5/8" / 15.88 mm Rated Capacity. . 12.000 Btu/h Remote Controller Wireless Minimum Capacity 2.800 Btu/h Outdoor Unit SEER ... 23.0 Btu/h/W Com r Total Input. .. 93 W MC A essix DC Inverter - driven Twin Rotary tall Heating at 47° F• Fan Motor . . 0.56 F.L.A Rated Capacity 13.600 Btu/h Sound Pressure Level Minimum Capacity 3.000 Btwh Cooling 48 dB(A) HSPF 10.6 Btu/h/W Healing 49 dB(A) Total Input . . ... . . . .950 W Heating at 17° F' DIMENSIONS INCHES / MM Rated Capacity 7.900 Btu/h W 31-1/2/800 Rated Total Input .... ... 750 W D 11-1/4 1 286 Maximum Capacity .. . . . . 13.600 Bluth H 21.5/81 549 Maximum Total Input 1.780 W • Rating Co trop • tCoow) . Indoor 80°F (27°CI 06 67°F (19°C) we anaoor 95°F Weight .. .80 lbs. / 36 k g (39°Q DS. 75°F (24°CI w8 External Finish . . . . Munsell No. 3.0Y 7.8 / 1 1 iHestngai4 7°F)- inclax OK) DO. 60'f (16'C)we Cutaoor 47°F (8 DS 43"F (eV; Ns Refrigerant Type R41 OA /lee' 817°F). inon r 70•F (21°Q, 0B. 60°F (16•D) Nt3. OUaoa 17°F (-8°C)06. 15T1-9.0 Mi Refrigerant Pipe Size O.U. Heating at 5° F Gas Side 3/8" / 9 52 mm Maximum Capacity .. . 12,500 Btu /h Liquid Side 1/4 1 6.35 mm Electrical Requirements Max. Refrigerant Pipe Length 65' ! 20 m Power Supply 208) 230V. 1-Phase, •Phase, 60 Hz Max Refngerant Pipe Height Difference . ... ... 40' / 12 m Breaker Size . . .. ..15 A Connection Method Flared Voltage /_. Indoor - Outdoor S1 -S2 . ..... . AC 208 / 230V 4 1 P I I Y Indoor . Outdoor S2 -S3 . DC 12-24V 'f t J ' C Wireless Remote Controller . ... DC to 2011 MITSUBISHI ELECTRIC 8. ELECTRONICS. INC • •• •. •. • • • • •. • • • • • •• • • • • • • • • •• .. •. 4 . .-- . •._ • .... DIMENSION ` T 12NA -8 K MUZ- FE12NA1 MSZ- FEI2NA -8 • .... •• • • • .• • • • • • • • • • • • • • Unit: inch • • • • • • • • 31 -3l: • • 7!•I . X 1 Obl • u hold • • • • . • • 7/16 X 13/16 • . . hole 30-718 1/2 • • 2 -1/2 : 7/8 :416 m Installation plate - r P- t •.• ••• •--.., • •• i NM MI =M - I - -I. ��M� 1 11 =1811..1 •• • • •� 0 a-a a • • •� • . . • . • • • .. •�• . • • • • • •• • • • •• 1 1 ^ r " 8 :'t 1 ilmill rn -Mt 13-9/16 'f. 1 • . 'lilt , I••_•, .r Air in Wall hol..2 -9/16 1. V 10.18 u4 Installation plate - /1 27 -1/16 - /1 - 111• m .11 314 m r y L I f .— : _ t . Drain hose rn Insulation 01.3/8 0.0 0 3.38 n Liquid Ine el /4 19 (Flared connection 01/4) Air out -1 .1. a Gas line 0318 16 -15/16 (Flared connection 03/8) Orarn hone Insulation 01 -118 O D Connected part 05/8 O.D MUZ- FE12NA1 Unit: inch 31 15 a � - -- - -.,r Dram hole J.1 - 5/8 «3 t 3 A. m REQUIRED SPACE Basically open 4 sine or more �_ without any obstiuWOn .n front t - __ I 1 N } } and on both Sides of the unit r a 1 F.. NI ( I 41 0 fur out �- t r- 6 • II • 2- 3/8 x 13/16 Oval hale �` 7/8 . `` ( ' ,I' 1* s'm• or e t harWle ' 181800888118811081111011881 2932 11.115 .I IIIIIIIIII )IIIIIIIIIIIIIIIIIIIIIIIIIIIII ) 1 _ Open two sties of len 1111111111111111111111111111111111111111 ngn or rear sde IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII )I I'l : , IIIIIIIIII )III)IIIIIIIIII)IIIIIIIIitlal I I n IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII _ III IIIIIIII )IIiIIIIIII)IIIIIIIIIIIIIII1I uen nnennuuu unn egnu ntiu 7 :— __ i .28r,12 I I. . Lii.30 381na ) ,yt 1a11�16 ,� ' .._ t 31 -1/2 2 -23/32 62332 MITSUBISHI /lik ELECTRIC A *JIM e— . .11 (;F.) U COOLING & HEATING ria 1.711 U S 3400 Lawrencewtle Suwanee Rd cymo Suwanee, GA 30024 Intertek Tele 678-376.2900• Fax 800-889-9904 Tot rms 8004334822 (#3) www mehvac com C FORMS 11MITSUBISHI ELECT & ELECTRONICS Specifications are subject to ch.nqe without nutlet • • • • • • • •• • • • • • • • • • • • • • • • • • . • • .. •• • • • • • • ••• • • • • • • • • • • • • • . • • • • • • • • • • • •• FLOOR PLAN ' .... .. .. . . • • • • • • . . • • • . • . • • • • •..• • • • • • •• ••• • ••• ••• Two Bedrooms with Two Baths • • • •• • • • • • • • • • Approx. 987 Sq.Ft. + 98 Sq.Ft. Storage • PitiO•• =••• •• • • rr} 1085 Sq.Ft. Total Living Space • "' • �1 , Y� 0 Bath / Q Storage �I � e .....poNv Living A" Room ; Bedroom Patio/ Deck Ba tb � 1 Kitchen Bedroom ■Im Dining Entry Room / \ A ° . / DO Left Kitchen Floorplan Bath ® ._ a X forage Bedroom L � Living O n Room Barn L Patio/ Deck 4 Bedroom 10 0 Kitchen -- Entr■ s Dining y i!` r e • Room Right Kitchen Floorplan �C����7 " n���/�� � » . —� -— '� —,_ __~—__ — - ___.� _ —_ ` • • • ^ ' � �_- ' ` . _ \ -. --_- - �� ___ -_~__-____� ___ ~ " ------ - -- � Z _- ' _ - � '�~~ � _'. ------ _ _-__'____ ' ~--- ' ^ ----- � U c ��� � --- --, ' ' �``r .�.� -_ `.�� � _ ��� ---------~~~_ � U� -- . '^_ ~` . .. . . .. - ' � - .� ____ --------_ �� �``. � |6 ` ^ p '- -� ' - ' � '`' - �_^ ' � ` ' � ` .: ` ' � '`�' •/ �- , � - ' . • � ' ` . , '~r, . • • • .:. _ BACK 4 . le; . , W 411 11 . J. •.• .1 11111111 . Ilk 4 41111. 4. lb • I . . ... . . • - 1111111111 ..i . - _ if. ' IP et .... . . _ . . • . . . . • . . - ' . . .... - 0 • -- . .. - - , /■ -.....--.,...............,„..........„..: O • : / -..... ,... . .... . 111111111 11-1111. . . . * 30 1111r • . ' 'Ille ' . . • . - . , . .. . . . • - - . - , .. _. •. _ . ....' 141111111111t-• . • tp.......... • --,--.----.,----.u.----- . • . , •.- .—.........- - . . • - . . • ... . '..."'...'"."""" . • . . - ; ' .,..... „,._ 7, — . "..* '• . 1 : 1 - , • • • • . • I ' : -' S'' • OS I .. -......,................,...- . . ' ... ' .""••••••••••”•••••••••• ..............,,-.........- ........ • i . L .. . ... • .....,..10.1••=muse...,....-..............w- ,„,,...,...,..........,..,.,,,,,, ,.. . •,- -.4 ._ .. . _ . . .. . - .......411111111111111MONL -.- . ' ' r '13 I ..- Ill 46 ' "I **'""1"- = 1111111alliatiliiiiiigoriediaiAlteit -:. 2.:!.....:: --- ......t..it.... ,..'... • , 0 . itC-rt.; _ • . ._ . — . , . _ . . . • . . . .. . . ..