Loading...
Specifications RE CEI VED Project Plan: Windmill Apartments Ductless Heat Pump Installation 1 N 1 G / ry 3 20 12 Submitted by: Jonathan Moscatello, The Heat Pump Store BU1( / p G4 70 Date: 1/13/12 1S /QN Address: 10587 SW Tigard St, Tigard, OR 97223 Owners: Jim and Sharon Richards Description: There are 20 identical structures at the property. Each structure is two stories tall, with two apartments on the CITYAF TIGARD lower level and two on the upper level. SEE ATTACHED FLOOR Approved . ^ T. .2/1 ? [ 6 -LAN. Conditionally Approved [ ] Sec setter to: Follow [ ] um We will install one ductless heat s stem (see attached Attached [ pump y Permit Number: t ?L a - CCV submittal, Mitsubishi MUZ /MSZ- FE12NA) for each apartment. Ad. • 4 - 1 03 I By: I ∎ Date: Z These are split systems, with an indoor "head" and an outdoor heat pump unit. The indoor and outdoor units are connected by BUNDLE containing two small refrigerant lines, a power and communications wire, and a condensate drain. OFFICE COPY U10 cr Installation Plan: A- a � ) OUTDOOR HEAT PUMP UNIT: The outdoor heat pump for each unit will be attached to the wall of each structure, just opposite of the storage unit for each apartment, using a manufacturer approved bracket (see BRACKET submittal, see exterior FRONT and BACK photos). The heat pumps will be installed approximately 12 inches above the ground level. They will be supplied with a 230V single phase electric circuit per the manufacturer's specifications using an outdoor disconnect. INDOOR "HEAD ": The indoor "head" unit for each outdoor heat pump will be attached to the living room wall of each apartment (see FLOOR PLAN). It will be connected to the outdoor unit by a so- called "bundle" of refrigerant lines, power /communications wire, and condensation drain line. The "bundle" will travel along the following pathway: from the outdoor unit, the bundle will travel to the nearest foundation vent, and enter into the crawlspace. The bundle will run through the crawlspace and penetrate into the storage unit through the floor. The bundle will run up the wall of the storage unit inside specialized conduit call "line cover ". At about head height, one of the sets of refrigerant lines, one power /communication wore and condensate drain will penetrate the storage unit wall and terminate at the head in the living room. All connections to the "head" will be made. Again the penetration will be sealed with fire caulk. The remainder of the bundle will continue upward toward the second story and the head in the living room of the upper unit. The remaining items in the bundle will penetrate the ceiling of the lower storage unit, enter the upper unit, and continue to the head for the upper unit. Again, connections will be made and penetrations sealed with fire caulk. MITSUBISHI /IL ELECTRIC Ire 111611 C O O L I N G & HEATING Split- ductless A/C and Heat Pumps SUBMITTAL DATA: CWMB1.. . "' HEAVYOUTY PAINTED STEEL WALL BRACKETS Job Name: Winmill Apartments Location: Tigard, OR' Date: 1/13/12 Purchaser: The Heat Pump Store Engineer: Submitted to For uReference ❑Approval Construction System Designation: Schedule No.: GENERAL FEATURES ASSEMBLY INSTRUCTION • The CWMB1 wall brackets are designed to provide a 1 Fit the vertical component to the horizontal arm by means to mount the Mr Slim M- Series. S- Series. P- Series inserting two TEM8X90 screws with four lock washers + and CITY MULTI PUMY - Series outdoor units on a suitable four flat washers + two self - locking nuts into the bracket wall or structure and keep the equipment off the ground components as illustrated The CWMB1 consists of two independently mounted wall brackets to allow proper leveling and support SELF - LOCKING! WASHERS WASHERS ` 8X90 SCREWS NUTS • The formed mild carbon steel two piece bracket is a > x4 (Lc) x8 x8 x4 rugged. fabricated, heavy duty accessory constructed for long reliable service life. The bracket is finished with an -- electrostatically applied, thermally fused acrylic or polyester powder coating for corrosion protection o x2 • The CWMB1 meets the intent and provides compliance with 'fa.) those codes requmng mounting HVAC equipment above ground level 0 `ms PLEASE NOTE a The Wall Bracket load capacity can only be assured if the installation is carried out properly (see drawing A) Drawing B illustrates an improper installation 2 Make sure the chosen installation location meets with specified requirements and wall design and construction is suitable and strong enough to hold the brackets and associated equipment loads Anchors and related mounting 440 lbs materials and hardware are the responsibility of the installer • 3 Avoid mounting the brackets and attached load on weak walls. 1 j 9 soft siding. veneer panels. perforated bricks / blocks or othei A insufficient mounting surfaces. h.lt is the responsibility of the Project Engineer and /or the Installing Contractor / Dealer to specify furnish, and install a x b any anchor or attachment materials required for the wall construction at the selected mounting location We are not 20.47" x 15.75" responsible for any installation faults or defects c It is strongly recommended to have the installation periodically inspected by a skilled technician ASSEMBLY Notes: ®2011 MITSUBISHI Et ECTRIC 8 ELECTRONICS. INC DIMENSIONS: CWMB1 1 J I ti, y ` .. 1 i f t I r t 1 i I 4° 9 r . �, -4 4,e Self locking tin( plated MO ✓. Class 11.8 zinc pWt<d steel — nut, white lUM 74741 screw. wMte. T.E. MISK3.54' (ISO40141 T.E. MBx90' L 0 f HEAVY DUTY WALL BRACKETS - '- Allik l COOLING & HEATING PARTNER 3400 Lawrenceville Suwanee Rd Suwanee. GA 30024 Tele 678-3762900 • Fax 800889 -9904 Toll Free 800-433.4822 (#3) www nlehvac corn FORMA C WMB 1 201108 Specifications are subject to change without notice. ® 2011 MITSUBISHI ELECTRIC 8 ELECTRONICS. INC Ar t MITSUBISHI ELECTRIC filfil COOLING & HEATING Split- ductleu A/C and Heat Pumps SUBMITTAL DATA: MSZ- FE12NA -8 8 MUZ- FE12NA1 12.000 BTUIH WALL- •OIINTFO HEAT PUMP SYSTEM Job Name: Windmill Apartments Location: Tigard, OR I Date: 1 /13/12 Purchaser: The Heat Pump Store Engineer: Submitted to: For OReference ❑Approval DConstruction System Designation: Schedule No.: GENERAL FEATURES in. . • Highly energy - efficient system that features 92% heating capacity _ _ at 5 "F, 75% at -4"F, and 58% at -13'F • Updated sleek, compact indoor unit design Iilllarrr,.t i :- _ , . • r Includes Standard, Platinum Deodorizing. and Anti- allergy En- MilegalangliF • zyme tillers for a complete air purifying system Powerful Mode function permits system to temporan run at - a lower/higher temperature with an increased fan speed, which tndoorunit MSZ FEI2NA.8 quickly brings the room to the optimum comfort level • Integrated i -see Sensor automatically adjusts the unit's operation - '' according to temperature differences detected between the floor Ai r • and the intake air, ensunng optimum comfort and energy usage • ""r'`. wa Carmaser • Hand-held Wireless Remote Controller outdoor link tltuZ FE12na1 • • Base heater is available as an option • Limited warranty: five years on parts and defects and seven OPERATING RANGE years on compressors OPTIONAL ACCESSORIES k ° """'"" r. p Dul00IX irWUMTarap Outdoor Unit Ma.rnun 50•r ; .2'CI 08 73°F 115 i48•Ci DB Base Heater (MAC- 640Dtt -U1 Godn9 Mmm,im R7°F 09°C , OH s7°r;ur_, n9 r4 r.,oC1 no • Drain Socket (MAC -851 DS) Marian; m e0•F i27°C1 D8 57'F ( ',r a 754 arc) DB. 854 (te•Ci W7/ Indoor Unit ~ essong Mrnerx" 704 (71°C) 08 (i0°F (18L^ i We -1341-25'C) [)8, -15°F rZ&Ct Ills" Condensate Pump (SI3100- 230, 230V) • ° ' c...... em ors as a -18 (- 26 to woe] trmnista war an recovers from c,nart Replacement Platinum Deodorizing Filter (MAC- 308FT) operational° adorreacsary roeartsat- 13°F( -25°C) Replacement Anti- allergy Enzyme Filter (MAC- 418FT: MERV 8) Indoor Unit Controller Options MCA 1 A . Wireless Remote Controller Kit (MHK1) with Remote Controller Fan Motor . 0.76 F.L A. • (MRCH1), Wireless Receiver (MIFH1), and cable (MRC1)• Airflow Setback down to 50 "F when used with MRCH1 Remote Controller Cooling (Lo - Med - Hi - Powerful) 162 - 226 - 381 - 410 Dry CFM Portable Central Controller (MCCH 1 for use with Wireless Remote 144 - 202 - 350 - 367 Wet CFM Controller Kit MHK1)• Healing (Lo - Med - Hi - Powerful) ..166 - 240 - 399 - 420 Dry CFM Outdoor Air Sensor (MOS1, for use with Remote Controller (MRCH1). Sound Pressure Level Wireless Remote Controller Kit (MHK1) and Portable Central Cooling (Lo - Med - Hi - Powerful) . . 22 - 33 - 43 . 45 dB(A) Controller (MCCH1)' Heating (Lo - Med - Hi - Powerful). 22 - 33 - 43 - 44 dB(A) 'See Sbtxnat* for oiOmahm on each °pro„ DIMENSIONS UNIT INCHES ! MM Wall- mounted Wired Remote Controller (PAR- 21MAA, req. MAC- 3971F) W 31.7/16/ 799 . MA Contact Terminal Interface (MAC- 397IF) I) 10 -1/8 r 257 . M -NET Control Adapter (MAC- 3991F) H 11 -5/8 / 295 Remote Temperature Sensor (M21 -JKO -307) Lockdown Bracket for Hand-held Controller (RCMKP1CB) Weight . . .. . .......... 27 lbs. / 12 kg Cooling' External Finish .. . .. ....Munsell No 1.0Y 9 2 / 0.2 Field Drainpipe Size O.D.. 5/8" / 15.88 mm Rated Capacity . . . • .. 12.000 Btu/h Remote Controller Wireless Minimum Capacity . 2.800 Btu/h Outdoor Unit SEER ... . 23.0 Blu/1WV ... .... DC Inverter -driven Twin Rota Total Input . 930 W MCA. Compressor Rotary • MCA . -.- ...12A Heating at 47° P Fan Motor. .... . 0.56 F.L.A Rated Capacity 13.600 Btu/h ' Sound Pressure Levet Minimum Capacity 3.000 Btu/h Cooling .48 dB(A) HSPF . . . 10 6 Btu/h/W Heating 49 dB(A) Total Input... ... . . .950 W - • Heating at 17° P DIMENSIONS INCHES / MM Rated Capacity . .. 7,900 Btu/h W 31 1/2 ! 800 Rated Total Input . 750 W D 11-1/4 1 286 Maximum Capacity . .. .... . . .... . .......13.600 Btu /h H 21. 5/8/549 Maximum Total Input 1 780 W • Rang Condrttoos iCootnQl - Indoor 80'F (27°CI 08.67'F (19°C) we Outdoor 95°F Weight (35•C) lbs. / 36 k (36•C) 7 C, v (24 B External Finish .. .. .. Munsell No. 3.OY 7.8 / 1 1 ( 14amga4 7 °F)- Moor 70°F(21°C) DB. 604(18°CIN cursor 474 (8Q OB 43°F Refrigerant Type . R410A (Heim Atm (. moon , 704 (21 V1121 O,popr 17°F (- 8r)08.15°FWC)WB Refrigerant Pipe Size O.D. Heating at 5° F Gas Side .... . . 3/8" / 9 52 mm Maximum Capacity... . ....... 12.500 Blu /h Liquid Side. ... . . we / 6 35 mm Electrical Requirements Max. Refrigerant Pipe Length 65 / 20 m Power Supply • .. .. ... 208 / 230V, 1- Phase, 60 Hz Max Refrigerant Pipe Height Difference 40' / 12 m Breaker Size .. . . .. ..15 A Connection Method Flared Voltage Indoor - Outdoor Sl -S2 . AC 208 / 230V 141P' I t t � p Indoor - Outdoor S2 -S3 . .... . .... DC 12 -24V `�/Y CR Wireless Remote Controller ..... .. ... DC / R C 2011 MITSUBISHI ELECTRIC 6 ELECTRONICS, INC DIMENSIONS: MSZ- FEI2NA -8 & MUZ- FE12NA1 MSZ FEI2NA - 8 Unit: inch 31-3/8 7/16 X 1 Oblong hole 7/16 X 13/16 Oblong L. 30 -7/8 1/2 n9 hole 2 -1/2 I 8-7/8 a -7/: m Installation plate - ^` • rO5 I '•• °i d� i_-II) ... indoor unit ....._......... ....... -11 , 13 -9/16 1 13 _2-11/16 Air ii ( Wall hole 02 t r -1 : 1/4 Installation date 1/1• 1• 27 -1/16 /1• Piing i24 III m m c `n N a �� f � Dfaln hose a Insulaiian 01- 3/80.D - L' a Liquid lave 01/4 19 -11/16 (Flared connection 01/4) AIr out 1 . i a Gas hne 03(8 16.15/16 (Flared connection 03/8) Oran hose Insulation e1 -118 O D Connected part 05/8 0.0 MUZ- FE12NA1 Unit: inch A 15.3/4 Oran hole 01 -5 /e 1 b Aid m REQUIRED SPACE 8as(ceny open 4 I n c h more 111_ a alihOui any obstruction .n front t _ ____ and on both sides of the unit 1 o f f m �) . r w -r 'r b Air out I . -- 1-9/16 2- 3/8 .13716 Oval hole III J • � 7/8 1 � , ry'"e k 1 handle nuuuilulmiuuulimltmllllluu — X 1t - IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII J � 1 r --- y Open twa sides of len. 111111111111111111111111111111111111111111 I ngnt or rear side. ; IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII '— I II IIIIIIIIHIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIM Y Illlllllilllllllllll111111111111111111C� IIIIIIIII IIIIIIIIIIIIIIIIIIIIIIIII nunnnununnuunuuuuuu ._= L H Lwow pipe 1/4 (flared) Gas pipe .3/8 (pared) 1(1 151. 19-16 -.-•. 31-1/2 �2 -23/32 0i:! Art i MITSUBISHI ELEGfRIC Au5,11 0ERTIFILD COOLING & HEATING - -- . , i- H r- _ • 3400 Lawrenceville Suwanee Rd GUS Suwanee, GA 30024 n tertek Tale 678- 376.2900 • Fax 800. 889.9904 To Free 800.433-4822 (#3) we rnehvac corn FORMS M ITSUBISHI ELECTRIC 8 ELECTRONICS INC Specifications an subject to change without notice. FLOOR PLAN Two Bedrooms with Two Baths Approx. 987 Sq.Ft. + 98 Sq.Ft. Storage & Patio = 1085 Sq.Ft. Total Living Space J tE ®Bath X e 4 e el Living •" Room I' n Bedroom Patio/ Deck B Kitchen 0 Bedroom Dining Entry Room if /� ° ' . . 09 Left Kitchen Floorplan �J 22 Barb ® ionise 0 Q .1 ' • Living Bedroom - • �— ® ; n Room N ^A., P , • u Deck / Bedroom 10 rE Kitchen Entr■ -� Dining ^ r---g. 2 I IN L!! Room Right Kitchen Floorplan FRONT J • �.. { ' .---------- • 1 ■ -..'--..--,,.. _ •.TSx.Y, ... T - �. 11- �_ __.._. . _.-._ .r-- _ _.-- .. -_._- . „....... -1.1...■- ............. .±n e t . �� ..- .-� -� ^_ • 4'i.' Y _-„-5� '+ ce. i i kr '4 BACK ter. _.... I. . ...., 111 aka.- _ ._ .._ . %. • . . - --- • _ ___ _ - - - - '---. - - . _ ' 4 1" - .........,..._ ' .. , . .., . '4W6.,, - I i . 1 ----.1111111 . .. • . , _„.... , . ,,. A . L , ,......,..........„,.... ........._ 41■Iiimer- gyve . ' Irli mos ' me •-.46ft...-:::.- it' 4,2,-,,,A7, -.. ,, .. ' , ' .. - : . . , . .4111.i..,4atiositOomiste,f_-• ::, , : i.. .--- 1— ' • • - . 4504 46 1 WOM-Plax,'i ,.. • . . - -- e""- -- • - - . . t . . •-•-:-.10.164".... 4441rik, As 4 • • — _. _ ." 1.. : .. .. . - 1 , ,, ,k • -,-,..... ,....„,,, .- omMov .,5 • '.' ,. '. . . .- . I i r , • :. 1 I . - '1 .'.; . . N 4 r • - - . . , ..-...,....-- .... -...-.I■ -...... ..............a..........-... - Illi , MU ' . . .. ..'-i, - - -, •..,;.,- :asishmena . z ...... .. .., .._..... . .. .: . , I . . ....ht„,„. . . . .