Specifications RECEIVED JAN 1 3 2012 Project Plan: Windmill Apartments Ductless Heat Pump Installati (TY OF TlGA� iD - BUILDING DIVISION Submitted by: Jonathan Moscatello, The Heat Pump Store Date: 1/13/12 Address: 10587 SW Tigard St, Tigard, OR 97223 Owners: Jim and Sharon Richards CIT, O 3'$i4 D There are 20 identical structures at the property. Each Approved ...ti AI :. P [ vtructure is two stories tall, with two apartments on the Conditionally Approved [ See Letter to: Follow [ ower level and two on the upper level. SEE ATTACHED FLOOR Attached [ 0LAN Permit Number: t rrCZ Ad e s:j��i� By: itiFilt Date: e will install one ductless heat pump system (see attached submittal, Mitsubishi MUZ /MSZ- FE12NA) for each apartment. Approved plans These are split systems, with an indoor "head" and an shall be e on on job site outdoor heat pump unit. The indoor and outdoor units are OFFICE COPY connected by BUNDLE containing two small refrigerant lines, a power and communications wire, and a condensate drain. Uhl Installation Plan: ;571 - ' OUTDOOR HEAT PUMP UNIT: The outdoor heat pump for each unit will be attached to the wall of each structure, just opposite of the storage unit for each apartment, using a manufacturer approved bracket (see BRACKET submittal, see exterior FRONT and BACK photos). The heat pumps will be installed approximately 12 inches above the ground level. They will be supplied with a 230V single phase electric circuit per the manufacturer's specifications using an outdoor disconnect. INDOOR "HEAD ": The indoor "head" unit for each outdoor heat pump will be attached to the living room wall of each apartment (see FLOOR PLAN). It will be connected to the outdoor unit by a so- called "bundle" of refrigerant lines, power /communications wire, and condensation drain line. The "bundle" will travel along the following pathway: from the outdoor unit, the bundle will travel to the nearest foundation vent, and enter into the crawlspace. The bundle will run through the crawlspace and penetrate into the storage unit through the floor. The bundle will run up the wall of the storage unit inside specialized conduit call "line cover ". At about head height, one of the sets of refrigerant lines, one power /communication wore and condensate drain will penetrate the storage unit wall and terminate at the head in the living room. All connections to the "head" will be made. Again the penetration will be sealed with fire caulk. The remainder of the bundle will continue upward toward the second story and the head in the living room of the upper unit. The remaining items in the bundle will penetrate the ceiling of the lower storage unit, enter the upper unit, and continue to the head for the upper unit. Again, connections will be made and penetrations sealed with fire caulk. MITSUBISHI NIL ELECTRIC Mir.SUM. C O O L I N G & HEATING Spfit- ductless A/C and Heat Pumps SUBMITTAL DATA: CWMB1.. ,., . HEAVY DUTY PAINTED STEEL WALL BRACKETS • Job Name: Winmill Apartments Location: Tigard, OR' 1 Date: 1/13/12 Purchaser: The Heat Pump Store Engineer: Submitted to: For Li Reference LiApproval lConstruction System Designation: Schedule No: GENERAL FEATURES ASSEMBLY INSTRUCTION • The CWMB1 wall brackets are designed to provide a 1 Fit the vertical component to the horizontal arm by means to mount the Mr Slim M- Series. S- Series. P- Series Inserting two TEM8X90 screws with four lock washers 4- and CITY MULTI PUMY - Series outdoor units on a suitable four flat washers + two self - locking nuts into the bracket wall or structure and keep the equipment off the ground components as Illustrated The CWMB1 consists of two independently mounted wall brackets to allow proper leveling and support SELF - LOCKING WASHERS WASHERS i BX90 SCREWS NUTS • The formed mild carbon steel two piece bracket is a O x �„ , x8 © x8 x4 rugged. fabricated, heavy duty accessory constructed for O 8 long reliable service life. The bracket is finished with an electrostatically applied, thermally fused acrylic or polyester powder coating for corrosion protection x2 • The CWMB1 meets the intent and provides compliance with ° r•, those codes requiring mounting HVAC equipment above ground level PLEASE NOTE - _ - - _ - ` - � I a The Wall Bracket load capacity can only be assured if the installation rs cared out properly (see drawing A) Drawing B illustrates an improper installation 2 Make sure the chosen installation location meets with specified requirements and wall design and construction 440 IbS • • is suitable als and strong enough to hold the brackets and associated equipment loads Anchors and related mounting materi and hardware are the responsibility of the installer 3 Avoid mounting the brackets and attached load on weak walls. soft siding. veneer panels. perforated bricks / blocks. or other A insufficient mounting surfaces b It is the responsibility of the Project Engineer and /or the Installing Contractor / Dealer to specify furnish. and install a x b any anchor or attachment materials required for the wall construction at the selected mounting location We are not 20.47" x 15.75" responsible for any installation faults or defects c It is strongly recommended to have the installation periodically inspected by a skilled technician ASSEMBLY Notes: t02011 MITSUBISHI ELECTRIC 8 ELECTRONICS. INC DIMENSIONS: CWMB1 i , I • II , I i "' I . ,,, 40.00".., or.....A00 r .-- -. 0 ,- Se 49. zinc y . �' Class 6.8 zinc pissed steel � _ - nut, white R0417474 l ed MB screw, white. U. MBx3.54" (15040141 I.E. M8x90' ` ° r} 1 HEAVY DUTY WALL BRACKETS MITSUBISHI , E - ", COOLING & HEATING PARTNER ' ve Better 3400 Lawrenceville Suwanee Rd Suwanee. GA 30024 Teo 678-376-2900 • Fax 800-889.9904 Td Free: 800 -433. 4822(#3) FORM# CVvMB1- 201 wwwmehvac.rxm © 2011 MITSUBISHI ELECTRIC 8. ELECTRONICS. INC. Specifications sn subject to change without notice. • MITSUBISHI /_ ELECTRIC mir.SLIIm. COOLING & HEATING Split- ductleu A/C and Heat Pumps SUBMITTAL DATA: MSZ- FE12NA -8 & MUZ- FE12NA1 12.000 BTU /H WALL - MOUNTED HEAT PUMP SYSTEM Job Name: Windmill Apartments Location:Tigard, OR I Date: 1/13/12 Purchaser: The Heat Pump Store Engineer: Submitted to: For LReference ❑Approval ❑Construction System Designation: Schedule No.: GENERAL FEATURES • Highly energy - efficient system that features 92% heating capacity at 5'F. 75% at -4 "F, and 58% al -13'F • Updated sleek. compact indoor unit design .. °r I • Includes St fll Staoard, Platinum a Deodorizing. rizing, and Anti-allergy En zyme fillers for r a complete air purifying system • Powerful Mode' function permits system to temporanly run at a lower/higher temperature with an increased fan speed, which Indoorunl MSLFE12NA -e quickly brings the room to the optimum comfort level • Integrated r -see Sensor automatically adjusts the unit's operation according to temperature differences detected between the floor . uI and the intake air, ensuring optimum comfort and energy usage O • Hand -hetd Wireless Remote Controller OWoor Uric ANJZ FE12NA1 • Base heater is available as an option • Limited warranty: five years on parts and defects and seven OPERATING RANGE years on compressors OPTIONAL ACCESSORIES 1n°°° hump As Tamp °1000 ""'^° ''" Outdoor Unit Ma°m 2 G un 90'F X De 73•F arc) ml 115•F i48°Ci De Cooing Base Heater (MAC - 6408I I - Mwnum e7•F 09°C) ore. 57°F /14 rte u•F, .,d11 Oa Drain Socket (MAC -851 DS) Maaanun eo°F arc) Da 87°F Itrc 'AB 75°F (24n) DB. 85•r ,15 C1 MI Indoor Unit " °"" Mrm+un 70•F Q1C) DB 00.F lteCi +rte -13'1' (- 25C108, •15•F ('28C1 the" Condensate Pump (SI3100 -230. 230V) '• System ans un at -18.r ( -28•C) to sepal lbwmato( ern Cul tacos, tram Wait Replacement Platinum Deodonzing Filter ( MAC- 308FT) operationar+o fidOmattalty +eatansat )3°Fr•25C) Replacement Anti- allergy Enzyme Filter (MAC- 418FT: MERV 8) Indoor Unit Controller Options MCA . .... 1 A Wireless Remote Controller Kit (MIiK1) with Remote Controller Fan Motor 0.76 F.L A (MRCH1). Wireless Receiver (MIFH1). and cable (MRC1)' Airflow Setback down to 501F when used with MRCH1 Remote Controller Cooling (Lo -Med - Hi - Powerful) 162 - 226 - 381 • 410 Dry CFM _. Portable Central Controller (MCCH 1 for use with Wireless Remote 144 • 202 - 350 - 367 Wet CFM Controller Kit MHK 1)• Heating (Lo -Med - HI - Powerful ....166 240 - 399 - 420 Dry CFM Outdoor Air Sensor (MOS1; for use with Remote Controller (MRCH1). Sound Pressure Level Wireless Remote Controller Kit (MHK1) and Portable Central Cooling (Lo - Med • Hi - Powerful) 22 - 33 - 43 - 45 dB(A) Controller (MCCH1)• Heating (Lo - Med • Hi - Powerful) 22 - 33 - 43 - 44 dB(A) 'See Submm1a1 tor ,rforinatwn on ea ii apeon DIMENSIONS UNIT INCHES / MM - Wall - mounted Wired Remote Controller (PAR•21MAA, req. MAC- 3971F) W 31 799 MA Contact Terminal Interface (MAC•397IF) D 10-1/8 / 257 : M -NET Control Adapter (MAC- 3991F) H 11. 5/81295 Remote Temperature Sensor (M21 -JKO.307) Lockdown Bracket for Hand -held Controller (RCMKP I CB) Weight . 27 lbs. / 12 kg External Finish . .. .. .Munsell No 1.0Y 9 2 / 0.2 Cooling' Field Drainpipe Size O.D.. .. 5/8" / 15.88 mm Rated Capacity 12.000 Blu /h Remote Controller Wireless Minimum Capacity 2,800 Btu/h Outdoor Unit SEER ... 23.0 Btu/h W Compressor . DC Inverter- driven Twin Rotary Total Input. . . .930 W MCA . ...12 A Heating at 47° F• Fan Motor . 0.56 F.L.A Rated Capacity . 13.600 Btu/h Sound Pressure Level Minimum Capacity .. 3.000 Btu/h Cooling .48 dB(A) HSPF 10.6 Btu/h/W Heating 49 dB(A) Total Input ... . . .. . . .950 W - Heating at 17° P DIMENSIONS INCHES / MM Rated Capacity /h 7.900 Btu W 31 - 1/2 / 800 Rated Total Input 750 W D 11 -1/4 / 286 Maximum Capacity 13.600 Btu/h H 21 -5/8 / 549 Maximum Total Input 1.780 W • Ratng Conditions (Coc %) - indoor 80•F (27^C! DB 67°F (19°C) we Outdoor 95°F Weight ..... . .80 lbs. / 36 k 135°C1 75°F(24°C)AG External Finish .. .. Munsell No 3.0Y 7.8 / 1 1 (maaa gat • tr+aoor 70' R1°Ci DB. 00T (16°C)0.11 ra,aoor 47'F 18008 47F 03 AB Refrigerant Type R410A (+laming at 1741.trldoor 70 • F (21°QDB 80°F (16•C)VNO.Oradon 1 7'Fi.BC)0B 1?F1•9C)AB Refrigerant Pipe Size O.D. Heating at 5° F Gas Side 3/8" / 9 52 mm Maximum Capacity.. 12.500 Bluth Liquid Side 114" / 6.35 mm Electrical Requirements Max. Refrigerant Pipe Length 65' 120 m Power Supply 208 1230V. 1-Phase, 60 Hz Max Refrigerant Pipe Height Difference . . .. ... 40' / 12 m Breaker Size . ...15 A Connection Method _ ... . .. Flared Voltage Indoor - Outdoor S1 -S2 . . AC 208 / 230V 411 I p Indoor - Outdoor S2 -S3 . .. . .... DC 12 -24V jR Wireless Remote Controller ... DC O 2011 MITSUBISHI ELECTRIC & ELECTRONICS. INC DIMENSIONS: MSZ-FE1 2NA-8 & MUZ FE12NA1 MSZ - FEI 2NA Unit: inch 31. . ._ 7/16 X 1 Obl. . hole 7/16 X 13/16 Oblong hole 1/2 - 112 8-7/8 : -7': Installation plate - r _ .QiIIIIMMIIIl•tlt•111 =11M1 n NW 0 Mnit IF 11•1111111111111111 11: 13-'116 /1. 1_ iit .... Air in Wall hole e2 -9/16 1 ' ' Installation .late 1. 27 -116 - 1. tr- 1E4 Pik. 2.54- I re 3i4 ill t liter_ - 1 , Drain hose 0 , Insulation 01 -3/8 0.0 0 M -•L n Liquid line m114 19 -11/16 (Flared connection e 1 /4) Air Out 1 . 1 a Gas line 03/8 16 -15/16 (Flared connection 03 /8) Drain hose Insulation 01 -1/8 OD Connected part m5/8 0.0 MUZ- FE12NA1 Unit: inch ,-_ -.15 -314 Drain hole 01 -5/8 tyAtrin REQUIRED SPACE 8asrca11yr1pen4 inch arntore .. i__ . without any obstruction in front (� `�'`�7 and on both sides of the unit Air a1 r { f N e o r or m et •••• ev r b Air out 4 7/8 2 - 3/8 x13/16 Oval "4/16 hole j j j I 1,' 1f 8 On' M ` herldlE IIIIIIIIIIIIIIIIIIIIIIIIIIIIfIIII hill n 29132 11-114 111111111111111111111111111111111111111111 Open two sees of left. III IIIIII IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII ; nght, or rear side. ._ IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIL --- IIIIIIII IIIIIIIIIIIIIIIIIIIIIIIIIII gllllllllilllliillllillllllllillllIMII lillll e I111111IIIIIIIIiIII IIIIIIIIIIIIIIIIIIIIII — h)))ill iiiiiilllllliiiiiil iudihlllb y 12>)�2 /' i . L Dice • 1(4 ((tared) j I • Iri - - -_ —. Gas pipe .3/8 (flared) 1 &11 /te . 31.1/2 2 -23132 6.23/32 I Art k MITSUBISHI ELECTRIC AM CERTIFIED. COOLING & HEATING (i' — . . e Better US 3400 Lawrenceville Suwanee Rd e Suwanee, GA 30024 Intertek Tide: 678-376-2900 • Fax: 800-889-9904 Tot Free 803433-4822 (#3) O 20 gZ ewemehvac.com # MITSUBISHI ELECTTR IC & ELECTRONICS. INC Specifications are subject to change without notice FLOOR PLAN Two Bedrooms with Two Baths Approx. 987 Sq.Ft. + 98 Sq.Ft. Storage & Patio = 1085 Sq.Ft. Total Living Space 11 y Q Storage ! j � � e r A ......\447 Living a„ Room Q 51 Bedroom Patio/ V Deck Batb 1 1 \ _._._ __ .............. Kitchen �� Bedroom Entry Dining Room a /1 A K ■ A , Left Kitchen Floorplan ® �•• j Ci forage l aath , a r Living Bedroom ® Room / tath Patio/ ` U Deck / Bedroom 1 0 uz Kitchen -- Entr Dining ‘ : 7 I (\ Fa Room Right Kitchen Floorplan y y A :. r I • 1 . 1 I ' lii , - "; --- l I 0 i Ail \ 4 , ! t ..3f;{r . L e i - .. 1 1 i iiiiii s 1 i �, "\., \ \ ,\ \ .'\. l'I '' ',. l ' . 1. 1 : r i r • '' ' ' ' ' • f! t 1.-- . \ \ \., ' ' , ; - \ I i,i‘iiii [ILA iti.... , CC LL p " s . • • t P. ,,I r . • • r...........„. .� ...� • . 141=11111116 Iry }.' .- it 1 - . 4441 ::: ; "- • —4 0. A.... 1:1 ii;:.;...?" 7 wo f e ll . 1 tiiiiimelika • • . e!"'#_:.1.... ..,... ,: . _ __ , • I