Loading...
Specifications RECEIVED JAN 1 3 2012 Project Plan: Windmill Apartments Ductless Heat Pump Installation` OFTIGA•D NG DIVISION Submitted by: Jonathan Moscatello, The Heat Pump Store - Date: 1/13/12 Address: 10587 SW Tigard St, Tigard, OR 97223 Owners: Jim and Sharon Richards Description: There are 20 identical structures at the property. Each structure is two stories tall, with two apartments on the lower level and two on the upper level. SEE ATTACHED FLOOR CITX O T , per, Approved 1 �� 1� [ ✓�_ Conditionally Approved [ We will install one ductless heat pump system (see attached See Letter to: Follow [ Att hed [ lubmittal, Mitsubishi MUZ /MSZ- FE12NA) for each apartment. Permit , Number :t2DIZ�GIL'I are split systems, with an indoor "head" and an Add •rim - „t ! P Y By: OW Date: M - s tdoor heat pump unit. The indoor and outdoor units are Approved plan. connected by BUNDLE containing two small refrigerant lines, shall be on job site a power and communications wire, and a condensate drain. OFFICE COPY ir+ Installation Plan: 615- k) �� 7 '�'� OUTDOOR HEAT PUMP UNIT: The outdoor heat pump for each unit will be attached to the wall of each structure, just opposite of the storage unit for each apartment, using a manufacturer approved bracket (see BRACKET submittal, see exterior FRONT and BACK photos). The heat pumps will be installed approximately 12 inches above the ground level. They will be supplied with a 230V single phase electric circuit per the manufacturer's specifications using an outdoor disconnect. INDOOR "HEAD ": The indoor "head" unit for each outdoor heat pump will be attached to the living room wall of each apartment (see FLOOR PLAN). It will be connected to the outdoor unit by a so- called "bundle" of refrigerant lines, power /communications wire, and condensation drain line. The "bundle" will travel along the following pathway: from the outdoor unit, the bundle will travel to the nearest foundation vent, and enter into the crawlspace. The bundle will run through the crawlspace and penetrate into the storage unit through the floor. The bundle will run up the wall of the storage unit inside specialized conduit call "line cover ". At about head height, one of the sets of refrigerant lines, one power /communication wore and condensate drain will penetrate the storage unit wall and terminate at the head in the living room. All connections to the "head" will be made. Again the penetration will be sealed with fire caulk. The remainder of the bundle will continue upward toward the second story and the head in the living room of the upper unit. The remaining items in the bundle will penetrate the ceiling of the lower storage unit, enter the upper unit, and continue to the head for the upper unit. Again, connections will be made and penetrations sealed with fire caulk. Ar t MITSUBISHI ELECTRIC M Ir. S LIIM, COOLING & HEATING Split- ductless A/C and Heat pumps SUBMITTAL DATA: CWMB1.. HEAVY DUTY PAINTED STEEL WALL BRACKETS Job Name: Winmill Apartments Location: Tigard, OR' Date: 1/13/12 Purchaser: The Heat Pump Store Engineer. Submitted to: For LReference LApproval LConstruction System Designation: Schedule No.: GENERAL FEATURES ASSEMBLY INSTRUCTION • The CVVMB1 wall brackets are designed to provide a 1 Fit the vertical component to the horizontal arm by means to mount the Mr Slim M- Series. S- Series. P- Series inserting two TEM8X90 screws with four lock washers + and CITY MULTI PUMY - Series outdoor units on a suitable four flat washers + two self - locking nuts into the bracket wall or structure and keep the equipment off the ground components as illustrated The CWMB1 consists of two independently mounted wall brackets to allow proper leveling and support SELF LOCKING WASHERS WASHERS 8X90 SCREWS NUTS • The formed mild carbon steel two piece bracket is a , p p rugged. fabricated. heavy duty accessory constructed for X4 S X8 ,' XS X4 long reliable service life. The bracket is finished with an electrostatically applied, thermally fused acrylic or polyester powder coating for corrosion protection o, 41 _ s_ x2 • The CWMB1 meets the Intent and provides compliance with . �;0 4 "."-...k those codes requiring mounting HVAC equipment above ti ;mo ground level ^� -------.....„___ '_ o PLEASE NOTE — _ _ a The Wall Bracket load capacity can only be assured if the — installation is carried out properly (see drawing AI Drawing B illustrates an improper installation 2. Make sure the chosen installation location meets with specified requirements and wall design and construction Is suitable and strong enough to hold the brackets and associated equipment loads Anchors and related mounting 440 IbS ; materials and hardware are the responsibility of the installer 3 Avoid mounting the brackets and attached load on weak wafs. g soft siding, veneer panels. perforated bricks / blocks or other A i nsufficient mounting surfaces. h It is the responsibility of the Protect Engineer and/or the Installing Contractor / Dealer to specify furnish, and install a x b any anchor or attachment materials required for the wall i construction at the selected mounting location We are not 20.47" x 15.75" responsible for any installation faults or defects c It is strongly recommended to have the installation periodically inspected by a skilled technician ASSEMBLY Notes: © 2011 MITSUBISHI ELECTRIC 8 ELECTRONICS. INC DIMENSIONS: CWMB1 : I i N_,} '' K / • } S, "" r �. • r , "14a9 Sea tacking tint plated MS - ,. ..,s# - ' Class LS Mc Rued steel nut. white (104174741 ^ . ... '' screw while. T.E. MSu354' pr' •i" (1504014) T.E. MSreO' ~ HEAVY DUTY WALL BRACKETS Ar MITSUBISHI ELECTRIC COOLING & HEATING PARTNER y fierier 3400 Lawrencew4e Suwanee Rd Suwanee. GA 30024 Tele 678 - 376 -2900. Fax 800-889-9904 Toll Free 800-433-4822 (#3) www tneM2c corn © 2011 C WM 81 201108 Speci.cadons are subject to change without nodes. © 2011 MITSUBISHI ELECTRIC & ELECTRONICS. INC A MITSUBISHI ELECTRIC M r. SLAM. COOLING & HEATING Spilt- ductless A/C and Heat Pumps SUBMITTAL DATA: MSZ- FE12NA -8 & MUZ- FE12NA1 12.000 BTU.H WALL- MOUNTED HEAT PUMP SYSTEM Job Name: Windmill Apartments Location Tigard, OR Date: 1 /13/12 Purchaser: The Heat Pump Store Engineer: Submitted to: For O Reference TiApproval ilConstruction System Designation: Schedule No.: GENERAL FEATURES • Highly energy- efficient system that features 82% heating capacity at 5`F. 75% at -4 "F, and 56% at -13`F • Updated sleek, compact indoor unit design ma.r i • Includes Standard, Platinum Deodorizing. and Anti - allergy En- it zyme fitters for a complete air purifying system • Powerful Mode' function permits system to temporanly run at a lower/higher temperature with an increased fan speed, which indoor U 1 MSZ.FEI2NA -8 quickly brings the room to the optimum comfort level • Integrated i -see Sensor automatically adjusts the unit's operation according to temperature differences detected between the floor A" • and the intake air, ensuring optimum comfort and energy usage "'7v: Wile ss n i o • Hand -held Wireless Remote Controller Outdoor Unit MUZ- FEt2NA1 • Base heater is available as an option • Limited warranty: five years on parts and defects and seven years on compressors OPERATING RANGE OPTIONAL ACCESSORIES " To m O i1Ooa I rmaAa lump Outdoor Unit Muaman 90•F (32T) De, 73•F a3 C) re 115E (ae c) 06 n Base Heater (MAC 640Bt1 - U) � Mninum 97'F (19°C) 0e. s7•F 411V1 kk9 14•F (.1OC) 08 n Drain Socket (MAC -851 OS) Maamvm Bart 27C) Da E7•c (19'C) we 75F (24°C) De. 86°F (fs°C) wt3 Indoor Unit r+m+u�o %known 70•F Q•C) De 60 (WC) Ali -13 (-MO De. -15F (•2e•C) vre•• ❑ Condensate Pump (SI3100 -230; 230V) •• system cubs owva- 1t'FROT) to avoid vwnrstorarca but maws from na ut n Replacement Platinum Deodorizing Filter ( MAC- 308FT) Marlton and erlanradcaey restarts at .13°F(25C) ci Replacement Anti allergy Enzyme Filter (MAC- 418FT: MERV 8) Indoor Unit Controller Options MCA .. .. . . .... 1 A Li Wireless Remote Controller Kit (MHK1) with Remote Controller Fan Motor ... ... 0.76 F.L A. (MRCH1), Wireless Receiver MIFH1), and cable MRCI)• Airflow ii Setback down to 50 "F when used with MRCH1 Remote Controller Cooling (Lo - Med - Hi - Powerful) ..162 - 226 - 38t - 410 Dry CFM D Portable Central Controller (MCCH1: for use with Wireless Remote 144 - 202 - 350 - 367 Wet CFM Controller Kit MHK1)° Heating (Lo - Med - H(- Powerful) . ..166 - 240 - 399 - 420 Dry CFM 0 Outdoor Air Sensor (MOS1; for use with Remote Controller (MRCH 1), Sound Pressure Level Wireless Remote Controller Kit (MHK1) and Portable Central Cooling (Lo - Med - Hi - Powerful) . . . 22 - 33 - 43 - 45 dB(A) Controller (MCCH1)• Heating (Lo - Med - Hi - Powerful) 22 - 33 - 43 - 44 dB(A) Submittal tor difonnabon each opfior DIMENSIONS UNIT INCHES 1 MM ❑ Wall- mounted Wired Remote Controller (PAR- 21MAA. req. MAC- 3971F) W 31 7/16/ a MA Contact Terminal Interlace (MAC- 3971F) D 10.118 / 257 a M -NET Control Adapter (MAC- 399lF) H 11- 5!81 ri Remote Temperature Sensor (M21 -JKO -307) • Lockdown Bracket for Hand -held Controller (RCMKPICB) Weight .27 lbs. / 12 kg Cooling' External Finish . Munsell No. 1.0Y 9.2 / 0.2 Rated Capacity Field Drainpipe Size O.D. 5/8" / 15.88 mm P y ....12,000 Btu/h Remote Controller Wireless Minimum Capacity ...2.800 Btu/h Outdoor Unit SEER ... .. 23.0 Btulh/W Total Input. . 930 W Compressor DC Irtvertar- driven Twin Rotary MCA... .. A Heating at 47° P Fan Motor ... 056 F.L A Rated Capacity 13,600 Bluth Sound Pressure Level Minimum Capacity 3.000 Btulh Cooling . 48 dB(A) HSPF . 10.6 BtuIhNV Heating 49 dB(A) Total Input . . . .. ,950 W Heating at 17° P DIMENSIONS INCHES / MM Rated Capacity . . 7,900 BtWh W 31 - 1/21 80C Rated Total Input ... 750 W D 11 -1/4 i 286 Maximum Capacity . .. ..... . .. 13.600 Btu/ti ,H 21.5/8 / 549 Maximum Total Input 1 780 W • Racing conditions ICoomg) • Indoor 80•F (27°C) Da. 67°F (19°C) NI Aadoar 9•F Weight ...80 lbs. / 36 kg (3s•C)DU M"F (24CC)we External Finish .. Munsell No. 3.0Y 7.8 / 1 1 , ` ,+e � '.;,, 7o (2 r0DB ( ) O J 17 F ( - ( 5F v a Refrigerant Type R410A Refrigerant Pipe Size O.D. Heating at 5° F Gas Side .. 3/8" 19.52 mm Maximum Capacity. . 12.500 Btu /h Liquid Side .... . ... 1/4" /6.35 mm Electrical Requirements Max. Refrigerant Pipe Length.. 65' / 20 m Power Supply . 208 / 230V. 1- Phase. 60 Hz Max Refrigerant Pipe Height Difference . 40' ! 12 m Breaker Size 15 A Connection Method . . .... Flared Voltage Indoor - Outdoor S1 -S2 . AC 208 / 230V I p Indoor Outdoor S2 -S3 .... DC 12 -24V Wireless Remote Controller DC 0 2011 MITSUBISHI ELECTRIC 8 ELECTRONICS, INC. DIMENSIONS: MSZ-FE1 2NA-8 & MUZ- FE12NA1 MSZ FEI2NA - 8 Unit: inch 31 -3/: 7/16 X I °don. hole 7/16 X 13/16 Oblong hole 30-7/8 1/2 2 -1/2 : 7/: :•?/: � Installation plate IN1 �ttl•��IMtl��t1■ ii 2.211��11111 ■ :�i IL - - : .� NW I ro rr - r ... - -1/6 13.9118 - IP i Air in Wall hole e2 -9116 Installation r ale 10 -1/8 114 It. - 1 27 -1/16 - /1 Pi. nil /4 m IP rbal.-- /,*:4: �� _ * 1 in e o , Insulation 01.3/8 0.D 1.-?. - 3 Liquid line e1t4 19 -11/16 ;Flared connection o114) - Air out 1 1. a Gas line 0318 16 -15/16 (Flared connecnon 0318) Drain hose Insulation el -1'8 0 D Connected part e5/8 0.13 MUZ- FE12NA1 Unit: inch 15-3/4 Drain hole t ? I 0 As In I REQUIRED SPACE Basically open 4 inch or more >ft titnthoul any obstruction in front I and on both sides of the unit el ra Air., r 1 p N , ,,„ „t,... \„. _ _ _ ... ... ,_ .„, 0 ,, OAirout � - 1-9/16 a 111111 AI 2- 318 .13!16 Oval note ` • 1 7/8 7 a ., h ,M if' g IIIIIIIIiiiiIIIIIIIIIIIUIllilllllllliiiil , I I 29/32 11.1/4 ■ IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII � - Open two s des left I 111111111111111111111111111111111101111 nyhL or rear S do m �I _ _ IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII —I IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII � _ I e) IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII 11 ' iIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII I :I multnuntulnnlllinntinuhuul JS .1. ; it. ,gw Ld pipe 1,4 (eared) _.. -'1 I - Gas pipe IA I1anrni 1501- 19. 11/16_ a� 1. 31-1/2 2 -23/32 23132 MITSUBISHI \ � ELECTRIC rm::.e /CERTIFILU COOLING & HEATING PARTNER " hertr " 3400 Lawrenceville Suwanee Rd GUS m Suwanee, GA 30024 Tele: 678-376.2900. Fax 800-889-9904 Intertek Toil Free 800-433-4822 1#3) gZZ wane mehvac eom FORM# C 01MITSUBISHI ELECTRIC 8 ELECTRONICS INC Specifications an subject to change without notice. FLOOR PLAN Two Bedrooms with Two Baths Approx. 987 Sq.Ft. + 98 Sq.Ft. Storage & Patio = 1085 Sq.Ft. Total Living Space Bath j ® �'� e Living - L Room n Bedroom Patio/ Deck ,,....41,:b/.\ Kitchen Dining Entry Room n / Left Kitchen Floorplan n Bath ® Q torsfe 0 a Living g Room Astb C 1 Patio/ Deck Bedroom 1 0 riZ Kitchen -- Entry s Dining k ri 2�A I+ Room Right Kitchen Floorplan Qo FRONT r^ - .. _ __._.-------------___ -; . _17_ :__.._._:_______.........._.......______ - _ Y . -- - __ _ '_- ___ .. __ -• m . • — _'+–.��� .� d �. -._. .�`' .,, --I la :, . -.1. li • • ?:,,, • .. . , te4r BACK - • , _ .. . • , - ar .. . .... IL . ile- . M. P qt., • . IMMO • 9, IP . • . . . - ■ .1, . _ • .. __ t . '''.....".^.............................. ,..13 ■ . l• • : I — ........_ . ...........—,. .... . . 111111.11111111111111.` IL- Via ' 1 9i WV . . 4.14, .Zbadif.. t. aill ' I 41.• .. . ..-- ......' - I Ill I I klli 1 I I f i • ,. 4 . .; . . ...- -... , .. . . , . .. ......... .. • • _ -• . 1 ! . t , .. ...... ___. .. . t -.16 ,. , i 4 . • i -• ---...r,,,...,,..---,..,.......,-._---.-.• - ---- . PPt P , • -- - - -- . . • . .. - ii1110117 ' -- ---- .. - ligke Oldla SI 1 '' 181 Av. ni dailIAM ' • - . t; ' • 'p - - - , iiigaitassl- • Virioaseata- . .,_ . - _ - . „... --, ___........,............. ---_— . .. .. . • r ailaMLZ.- . . . . . . •