Loading...
Specifications ✓q ., I v �� B� „.: $0, 3204 0/Np 4 0 Project Plan: Windmill Apartments Ductless Heat Pump Installation pN Submitted by: Jonathan Moscatello, The Heat Pump Store Date: 1/13/12 Address: 10587 SW Tigard St, Tigard, OR 97223 Owners: Jim and Sharon Richards Description: There are 20 identical structures at the property. Each structure is two stories tall, with two apartments on the 4ppro C OF Tr Af� wer level and two on the upper level. SEE ATTACHED FLOOR .onditionally Approved [ PLAN. lee Letter to: Follow r Attached We will install one ductless heat pump system (see attached Omit Nt .. •er: A.4 7 012 • v , ddres ..• ,, , •. ar submittal, Mitsubishi MUZ /MSZ- FE12NA) for each apartment. y: erl Date: 1 '2-- are split systems, with an indoor "head” and an Approved plans outdoor heat pump unit. The indoor and outdoor units are shall be on job site. connected by BUNDLE containing two small refrigerant lines, a power and communications wire, and a condensate drain. OFFICE COPY Installation Plan: I ) 2) OUTDOOR HEAT PUMP UNIT: The outdoor heat pump for each unit will be attached to the wall of each structure, just opposite of the storage unit for each apartment, using a manufacturer approved bracket (see BRACKET submittal, see exterior FRONT and BACK photos). The heat pumps will be installed approximately 12 inches above the ground level. They will be supplied with a 230V single phase electric circuit per the manufacturer's specifications using an outdoor disconnect. INDOOR "HEAD ": The indoor "head" unit for each outdoor heat pump will be attached to the living room wall of each apartment (see FLOOR PLAN). It will be connected to the outdoor unit by a so- called "bundle" of refrigerant lines, power /communications wire, and condensation drain line. The "bundle" will travel along the following pathway: from the outdoor unit, the bundle will travel to the nearest foundation vent, and enter into the crawlspace. The bundle will run through the crawlspace and penetrate into the storage unit through the floor. The bundle will run up the wall of the storage unit inside specialized conduit call "line cover ". At about head height, one of the sets of refrigerant lines, one power /communication wore and condensate drain will penetrate the storage unit wall and terminate at the head in the living room. All connections to the "head" will be made. Again the penetration will be sealed with fire caulk. The remainder of the bundle will continue upward toward the second story and the head in the living room of the upper unit. The remaining items in the bundle will penetrate the ceiling of the lower storage unit, enter the upper unit, and continue to the head for the upper unit. Again, connections will be made and penetrations sealed with fire caulk. Al I t MITSUBISHI ELECTRIC Ire 5 LLO . COOLING & HEATING Split - ductless A/C and Heat Pumps SUBMITTAL DATA: CWMB1.. HEAVY DUTY PAINTED STEEL WALL BRACKETS Job Name: Winmill Apartments Location: Tigard, OR I Date: 1/13/12 Purchaser: The Heat Pump Store Engineer: Submitted to: For LReference ❑Approval ElConstruction System Designation: Schedule No.: GENERAL FEATURES ASSEMBLY INSTRUCTION • The CWMB1 wall brackets are designed to provide a 1 Fit the vertical component to the horizontal arm by means to mount the Mr Slim M- Series. S- Series. P -Series inserting two TEM8X90 screws with four lock washers + and CITY MULTI PUMY - Series outdoor units on a suitable four flat washers + two self - locking nuts into the bracket wall or structure and keep the equipment off the ground components as illustrated The CWMB1 consists of two Independently mounted wall brackets to allow proper leveling and support SELF - LOCKING! WASHERS WASHERS 8X90 SCREWS NUTS • The formed mild carbon steel two piece bracket Is a p rugged. fabricated. heavy duty accessory constructed for x4 �� x8 x0 �? x4 long reliable service life. The bracket is finished with an electrostatically applied, thermally fused acrylic or polyester powder coating for corrosion protecton ro ; x2 • The CWMB1 meets the intent and provides compliance with moo, ,y those codes requiring mounting HVAC equipment above ground level 0 o PLEASE NOTE a The Wall Bracket load capacity can only be assured if the installation is carried out properly (see drawing Ai Drawing B illustrates an improper installation 2 Make sure the chosen installation location meets with specified requirements and wall design and construction is suitable and strong enough to hold the brackets and associated equipment loads Anchors and related mounting 440 lbs • X materials and hardware are the responsibility of the installer 3 Avoid mounting the brackets and attached load on weak wals, soft siding. veneer panels. perforated bricks / blocks or other A insufficient mounting surfaces. h Its the responsibility of the Protect Engineer and /or the Installing Contractor / Dealer to specify furnish, and install a x b any anchor or attachment materials required for the wall construction at the selected mounting location We are not 20.47" x 15.75" responsible for any installation faults or defects. c It is strongly recommended to have the installation periodically inspected by a skilled technician ASSEMBLY Notes: © 2011 MiTSUBISHI ELECTRIC & ELECTRONICS. INC DIMENSIONS: CWMB1 ?' • g a r . • r ) o, r •19 ! i . / � j 1 - r r - v„ot Self ticking tinc plated MB - / Gass BArntpaWcIssee) nut. white(UN174M tcr �f n screw. white, I.E. Mad 54" (.040) 4)11. MBM90' HEAVY DUTY WALL BRACKETS MITSUBISHI ., ELECTRIC COOLING & HEATING PARTNER getter 3400 Lawrenceville Suwanee Rd Suwanee, GA 30024 Tele: 678 -376 -2900 • Fax 800-889 -9904 To Free: 800 - 433 -4822 (#3) www mehvac.00m FORMS C 1- 201108 Spe cifcationsare subject to change without notice. ® 2011 MITSUBISHI ELECTRIC & ELECTRONICS. INC. ar.l & MITSUB ELECTRIC ISHI Ar OM If. SiIIf M. COOLING & HEATING Split -ductless A/C and Heat Pumps SUBMITTAL DATA: MSZ- FE12NA -8 8 MUZ- FE12NA1 12.000 BTUiH WALL - MOUNTED HEAT PUMP SYSTEM Job Name: Windmill Apartments Location:Tigard, OR I Date: 1/13/12 Purchaser: The Heat Pump Store Engineer: Submitted to: For ❑Reference ❑Approval ❑Construction System Designation: Schedule No.: GENERAL FEATURES • Highly energy - efficient system that features 92% heating capacity at 5'F. 75% at -4"F, and 58% at -13`F • Updated sleek, compact indoor unit design f lleo n'"1. -...: r, • Includes Standard. Platinum Deodorizing, and Anti- allergy En- gailtallSailliF • zyme filters for a complete air purifying system Powerful Mode function permits system to temporarily run at - a lower/higher temperature with an increased fan speed, which indoor unit MSZ- FEI2NA -8 quickly brings the room to the optimum comfort level • Integrated i -see Sensor automatically adjusts the unit's operation according to temperature differences detected between the floor ' so and the intake air- ensuring w.e comfort and energy usage Ccotriger • Hand -held WIreless Remote oController e Outdoor Lint MU2 fE12NA1 • Base heater is available as an option • Limited warranty: five years on parts and defects and seven OPERATING RANGE years on compressors OPTIONAL ACCESSORIES Irmo "* ' " " T. 010001 "' a ' A°Ta '" p Outdoor Unit Mnmum 90°F (32•C) 08 73°F (23•C) vie 115°F 14e•ci De cooing • Base Heater (MAC- 640BH -U1 Mmn um 97•F (19°Ci 08.57 (14 •C u9 14°F - 06 Drain Socket (MAC -851 DS) Marnnum ear (27°C) 06 67°F (19°C) 'AB 75°F (24°C) D8 65•F 18°C 1AL' Indoor Unit " "`.° sun,,,,,, 70°F (21°C) 08 60°F 16°C; AS -13°F r -25•0) Da. -15°F t26.0 NB" Condensate Pump (513100-230, 230V) •• slalom ass 4 al -19•F (-28°C1 lo aria toe rnstor error an rrxcvera from c,W 4 Replacement Platinum Deodonzing Filter (MAC- 308FT) operaeon am/ astomaticaay restarts at- 13°F1-25°C) Replacement Anti - allergy Enzyme Filter (MAC4418FT. MERV 8) Indoor Unit Controller Options i MCA 1 A • Wireless Remote Controller Kit (MHK11 with Remote Controller Fan Motor 0.76 F.L A (MRCH1). Wireless Receiver (MIFH1), and cable (MRC1)• Airflow . Setback down to 50 "F when used with MRCH1 Remote Controller I Cooling (Lo - Med - Hi - Powerful) . . 162 - 226 - 381 - 410 Dry CFM - Portable Central Controller (MCCH1 for use with Wireless Remote 144 - 202 - 350 - 367 Wet CFM Controller Kit MHK1)* Heating (Lo - Med - Hi - Powerful) ... .166 - 240 - 399 - 420 Dry CFM Outdoor Air Sensor (MOS1; for use with Remote Controller (MRCH1), Sound Pressure Level Wireless Remote Controller Kit (MHK1) and Portable Central Cooling (Lo - Med - Hi - Powerful) . . 22 - 33 - 43 . 45 dB(A) Controller (MCCH1)' Heating (Lo - Med - Hi - Powerful). 22 - 33 - 43 - 44 dB(A) 'See 5uimstai tor ir$orn rison on each weal DIMENSIONS UNIT INCHES 1 MM 1 Wall- mounted Wired Remote Controller (PAR -21 MAA, req. MAC-3971F) W 31. 71161 799 MA Contact Terminal Interface (MAC- 3971F) D 10-118 / 257 M -NET Control Adapter (MAC- 3991F) H 11-5/8 / 295 Remote Temperature Sensor (M21- JKO.307) Lockdown Bracket for Hand -held Controller (RCMKPI CB) Weight . ... . ... . ........ .... lbs. 1 12 kg External Finish . . .. .. ....Munsell No. 1.0Y 9 2 / 0.2 Cooling' Field Drainpipe Size 0.D. 5 /8" / 15.88 mm Rated Capacity. 12.000 Blu/h Remote Controller ... Wireless Minimum Capacity . 2.800 Blu/h Outdoor Unit SEER ... 23.0 Blu/h/W Total Input. . . 930 W Compressor DC Inverter - driven Twin Rotary MCA... ...... . .....12A Heating at 47° F• Fan Motor . . .. .. . . 0.56 F.L.A Rated Capacity . . 13,600 Blu/h Sound Pressure Level Minimum Capacity .. . 3.000 Btu/h Cooling . . . .48 dB(A) HSPF 10.6 Btu/h/W Heating . 49 dB(A) Total Input. 950W DIMENSIONS INCHES / M M • Heating at 17° P yy 31 Rated Capacity - 7.900 Btu/h Rated Total Input - ... 750 W 0 11 -1/4 / 286 Maximum Capacity. .. ..... . 13.600 Btu /h H 21 -5/8 / 549 Maximum Total Input 1 780 W • Rang Conikimi nor (Cookng) - ulrloor 80°F (27•CI DB. 67°F (19°C) we ouooa 95°F Weight . . . . ..80 lbs. / 36 kg 135°C) DB. 75°F (24°C) w e External Finish .. .. Munsell No. 3.0Y 7.8 / 1 1 (>♦ mag at 47° F)- kfooar 7PF(2 i° k)06. 60° Fl1e •C) AB. Culbor 47°18(1°B Refrigerant Type . R410A (Hear cal1 -Moor 70 60 17°F -eC) 15°F (4,Clvte Refrigerant Pipe Size O.D. Heating at 5° F Gas Side . . 3/8" / 9 52 mm Maximum Capacity ... 12.500 Btu/h Liquid Side. . 1/4" / 6 35 mm Electrical Requirements Max. Refrigerant Pipe Length 65' / 20 m Power Supply ........ .. .... 208 / 230V. 1- Phase, 60 Hz Max Refigerant Pipe Height Difference 40' / 12 m Breaker Size 15 A Connection Method . Flared Voltage Indoor - Outdoor S1 -S2 . AC 208 / 23V )41P I Ispil Indoor - Outdoor S2 -S3 . - .. . ... - DC 12-24V Wireless Remote Controller ... DC to 2011 MITSUBISHI ELECTRIC 6 ELECTRONICS, INC DIMENSIONS: MSZ- FEI2NA -8 & MUZ FE12NA1 MSZ- FEI2NA -8 Unit: inch — — 30 -3/8 -- 7/16 X 1 Oblong hole 7/16 X 13/16 Oblong hole 1/2 ` — ` I —I- 2 -1/2 8 -7/8 :•7I: ti �I.I•l1111■ ,-a- Installation plate ur , _ ____ _ zi6., lei - 11: 13 -•/16 e indoor unit Air in Wall hole e2 -9/16 V 10 1/8 1/4 Installation date n 27 -1116 tf Pi•' ` f...1 -11/16 2-5116 r m �It _ ` 11 - 1 • \ Drain hose a NI Insulation 01.3/8 0.0 f?' - • MI a Liquid hoe 0114 19 - 11/16 (Flared Connection 01/4) - -- Air out 1 .1. a Gas line 03/8 16.15/16 (Flared connection 0318) Dram hose Insulation el -I /6 0 Connected part m5/8 0.0 MUZ -FEI 2NA1 Unit: Inch v 15. 314 - - -.. Dram note 0l.503 . to REQUIRED SPACE Basrceny open 4 inch co more wdhout any obstrurxian ,n Iron! 4 I and on both sides of the unit f ' i Ar M t7 L m r i' N -; q 1 , I I 0 Air out 4- 1.9116 - r— 7/8 2- 3/8 13/76 Oval hole - `` I II , t �� r \ v im ♦+ f /,• ry °br hasidle - it 111111111111111111‘111i11111 lllllllllll 29%32 11 - /4 � IIIIIIIIIIIIIIIIIIIIIIIIIIIIHIIIIIIIIII 1 - 11 Open two sties of led. IIIIII11 IIIIIIIIIIIIIIIIIIIIIIIHIHH III right, or rear side. ! IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII NI a IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII) �, 1111111111111111111111111111111111111111 IIIIIIIIIIIIIIiIIIIIIIIIIIIIIiIIIIIIIIII 04 "1 _i _i - -- - - -. r rid. - .___.- a, I . Liquid pipe 114 (flared) 1. 19.11/16 + - Gas pipe .318 (Oared) - - , — 31.1/2 -f 2 13132 6r23i3 • I MITSUBISHI f ELECTRIC O� CE RTItILD ' 2^ COOLING & HEATING i PARTNER -,..— • '•` F e r t e' 3400 Lawrencevi Su e wanes Rd SUS p ' t Suwanee, GA 30024 I n tertek Tele 678. 376.2900 • Fax 800. 889-9904 Toll Free 800-433-48221003) www mehvac com FORM# MSZ -FE 12NA -8 - MUZ -F E 12NA 1 - 201108 Specifications an subject to change without notice. C 2011 MITSUBISHI ELECTRIC 6 ELECTRONICS INC FLOOR PLAN Two Bedrooms with Two Baths Approx. 987 Sq.Ft. + 98 Sq.Ft. Storage & Patio = 1085 Sq.Ft. Total Living Space Y ^ Bath / H Storage 11 ® r} V r Living a 0 - Room n Q Y Bedroom Patio/ V Deck , Bath 1 ■ Kitchen Iw/n D) Bedroom Dining Room �j /v y '. rao Left Kitchen Floorplan n Bath ® forage uU 0 w W A Livin Bedroom ' Y Room ( \ lath Patio/ / Deck Bedroom [] = Kitchen -- Bntr:. Din 2111 N. • • Room Right Kitchen Floorplan | FRONT • o /v��n� v %..., » ' � � - _ `^ . • _ - ' _ ' '� - - - � `.� ~ '� '~`'�° - —_- :. ---- ' ____--�� ___� - _-_ ` `- . __ _' ° __-__~__- '- ' .. _-__ ___ __ � L. �� ----' ' | ,_ ' __- • -______� ___ ___-_- __-___-� __ � ' � . -__ • ., __-__--__- ^ /' ! B — ---' ., i � _ _ . " ~�� ____. ' y r-- .. -- l ' N� �� � ' n ----- --- -�----- . ~� _ �_-- � . ' '�. �m����� ' `—' . '-------'-- • ��' � _ � �` ^ `^'�N��` ' _ � ' ' _ ��N�� ���__ __ ^'`- _-_____��_��� ,��� t � p __ ` � -_~~____- '_~~_-'_ -�� `����N« ^� �` � ow '` t�r, :-- ' . . " . . • • BACK JO' 11/ a ■-• —. . • . . • . -- • Or . `,---",,Aii‘c. • . • - -...........................--- - - . , -"". - / ' 19 IIP - ••.; As : • :46. ...,-, I n 1 .... 4.1 i . — '"°"'"'"--■--.....--- .. . . . i • . _ . - ..., . .. . _._. i ■ ,, .., . . . i . . .. . . A .. ; - 1 - . , • . . _ . . , , ' •. , _ ........ . . _., . ....i i roi - .--•---.•••- . -, ....•; "ralt,iiisty fill ...:' ..,., ■rafor . ••■• - ' gositaii.:. . . I* — — . -- _. . . . •- .• - 11111111Eglait.:,A.k;. AI. """" t "' AM . - . - - . • ... __ _____ ... .. • . • . . • . . . . . p , ,.. • . • . - . . .,. - . , . . . . . . . . . . . . . . . ✓q ., I v �� B� „.: $0, 3204 0/Np 4 0 Project Plan: Windmill Apartments Ductless Heat Pump Installation pN Submitted by: Jonathan Moscatello, The Heat Pump Store Date: 1/13/12 Address: 10587 SW Tigard St, Tigard, OR 97223 Owners: Jim and Sharon Richards Description: There are 20 identical structures at the property. Each structure is two stories tall, with two apartments on the 4ppro C OF Tr Af� wer level and two on the upper level. SEE ATTACHED FLOOR .onditionally Approved [ PLAN. lee Letter to: Follow r Attached We will install one ductless heat pump system (see attached Omit Nt .. •er: A.4 7 012 • v , ddres ..• ,, , •. ar submittal, Mitsubishi MUZ /MSZ- FE12NA) for each apartment. y: erl Date: 1 '2-- are split systems, with an indoor "head” and an Approved plans outdoor heat pump unit. The indoor and outdoor units are shall be on job site. connected by BUNDLE containing two small refrigerant lines, a power and communications wire, and a condensate drain. OFFICE COPY Installation Plan: I ) 2) OUTDOOR HEAT PUMP UNIT: The outdoor heat pump for each unit will be attached to the wall of each structure, just opposite of the storage unit for each apartment, using a manufacturer approved bracket (see BRACKET submittal, see exterior FRONT and BACK photos). The heat pumps will be installed approximately 12 inches above the ground level. They will be supplied with a 230V single phase electric circuit per the manufacturer's specifications using an outdoor disconnect. INDOOR "HEAD ": The indoor "head" unit for each outdoor heat pump will be attached to the living room wall of each apartment (see FLOOR PLAN). It will be connected to the outdoor unit by a so- called "bundle" of refrigerant lines, power /communications wire, and condensation drain line. The "bundle" will travel along the following pathway: from the outdoor unit, the bundle will travel to the nearest foundation vent, and enter into the crawlspace. The bundle will run through the crawlspace and penetrate into the storage unit through the floor. The bundle will run up the wall of the storage unit inside specialized conduit call "line cover ". At about head height, one of the sets of refrigerant lines, one power /communication wore and condensate drain will penetrate the storage unit wall and terminate at the head in the living room. All connections to the "head" will be made. Again the penetration will be sealed with fire caulk. The remainder of the bundle will continue upward toward the second story and the head in the living room of the upper unit. The remaining items in the bundle will penetrate the ceiling of the lower storage unit, enter the upper unit, and continue to the head for the upper unit. Again, connections will be made and penetrations sealed with fire caulk. Al I t MITSUBISHI ELECTRIC Ire 5 LLO . COOLING & HEATING Split - ductless A/C and Heat Pumps SUBMITTAL DATA: CWMB1.. HEAVY DUTY PAINTED STEEL WALL BRACKETS Job Name: Winmill Apartments Location: Tigard, OR I Date: 1/13/12 Purchaser: The Heat Pump Store Engineer: Submitted to: For LReference ❑Approval ElConstruction System Designation: Schedule No.: GENERAL FEATURES ASSEMBLY INSTRUCTION • The CWMB1 wall brackets are designed to provide a 1 Fit the vertical component to the horizontal arm by means to mount the Mr Slim M- Series. S- Series. P -Series inserting two TEM8X90 screws with four lock washers + and CITY MULTI PUMY - Series outdoor units on a suitable four flat washers + two self - locking nuts into the bracket wall or structure and keep the equipment off the ground components as illustrated The CWMB1 consists of two Independently mounted wall brackets to allow proper leveling and support SELF - LOCKING! WASHERS WASHERS 8X90 SCREWS NUTS • The formed mild carbon steel two piece bracket Is a p rugged. fabricated. heavy duty accessory constructed for x4 �� x8 x0 �? x4 long reliable service life. The bracket is finished with an electrostatically applied, thermally fused acrylic or polyester powder coating for corrosion protecton ro ; x2 • The CWMB1 meets the intent and provides compliance with moo, ,y those codes requiring mounting HVAC equipment above ground level 0 o PLEASE NOTE a The Wall Bracket load capacity can only be assured if the installation is carried out properly (see drawing Ai Drawing B illustrates an improper installation 2 Make sure the chosen installation location meets with specified requirements and wall design and construction is suitable and strong enough to hold the brackets and associated equipment loads Anchors and related mounting 440 lbs • X materials and hardware are the responsibility of the installer 3 Avoid mounting the brackets and attached load on weak wals, soft siding. veneer panels. perforated bricks / blocks or other A insufficient mounting surfaces. h Its the responsibility of the Protect Engineer and /or the Installing Contractor / Dealer to specify furnish, and install a x b any anchor or attachment materials required for the wall construction at the selected mounting location We are not 20.47" x 15.75" responsible for any installation faults or defects. c It is strongly recommended to have the installation periodically inspected by a skilled technician ASSEMBLY Notes: © 2011 MiTSUBISHI ELECTRIC & ELECTRONICS. INC DIMENSIONS: CWMB1 ?' • g a r . • r ) o, r •19 ! i . / � j 1 - r r - v„ot Self ticking tinc plated MB - / Gass BArntpaWcIssee) nut. white(UN174M tcr �f n screw. white, I.E. Mad 54" (.040) 4)11. MBM90' HEAVY DUTY WALL BRACKETS MITSUBISHI ., ELECTRIC COOLING & HEATING PARTNER getter 3400 Lawrenceville Suwanee Rd Suwanee, GA 30024 Tele: 678 -376 -2900 • Fax 800-889 -9904 To Free: 800 - 433 -4822 (#3) www mehvac.00m FORMS C 1- 201108 Spe cifcationsare subject to change without notice. ® 2011 MITSUBISHI ELECTRIC & ELECTRONICS. INC. ar.l & MITSUB ELECTRIC ISHI Ar OM If. SiIIf M. COOLING & HEATING Split -ductless A/C and Heat Pumps SUBMITTAL DATA: MSZ- FE12NA -8 8 MUZ- FE12NA1 12.000 BTUiH WALL - MOUNTED HEAT PUMP SYSTEM Job Name: Windmill Apartments Location:Tigard, OR I Date: 1/13/12 Purchaser: The Heat Pump Store Engineer: Submitted to: For ❑Reference ❑Approval ❑Construction System Designation: Schedule No.: GENERAL FEATURES • Highly energy - efficient system that features 92% heating capacity at 5'F. 75% at -4"F, and 58% at -13`F • Updated sleek, compact indoor unit design f lleo n'"1. -...: r, • Includes Standard. Platinum Deodorizing, and Anti- allergy En- gailtallSailliF • zyme filters for a complete air purifying system Powerful Mode function permits system to temporarily run at - a lower/higher temperature with an increased fan speed, which indoor unit MSZ- FEI2NA -8 quickly brings the room to the optimum comfort level • Integrated i -see Sensor automatically adjusts the unit's operation according to temperature differences detected between the floor ' so and the intake air- ensuring w.e comfort and energy usage Ccotriger • Hand -held WIreless Remote oController e Outdoor Lint MU2 fE12NA1 • Base heater is available as an option • Limited warranty: five years on parts and defects and seven OPERATING RANGE years on compressors OPTIONAL ACCESSORIES Irmo "* ' " " T. 010001 "' a ' A°Ta '" p Outdoor Unit Mnmum 90°F (32•C) 08 73°F (23•C) vie 115°F 14e•ci De cooing • Base Heater (MAC- 640BH -U1 Mmn um 97•F (19°Ci 08.57 (14 •C u9 14°F - 06 Drain Socket (MAC -851 DS) Marnnum ear (27°C) 06 67°F (19°C) 'AB 75°F (24°C) D8 65•F 18°C 1AL' Indoor Unit " "`.° sun,,,,,, 70°F (21°C) 08 60°F 16°C; AS -13°F r -25•0) Da. -15°F t26.0 NB" Condensate Pump (513100-230, 230V) •• slalom ass 4 al -19•F (-28°C1 lo aria toe rnstor error an rrxcvera from c,W 4 Replacement Platinum Deodonzing Filter (MAC- 308FT) operaeon am/ astomaticaay restarts at- 13°F1-25°C) Replacement Anti - allergy Enzyme Filter (MAC4418FT. MERV 8) Indoor Unit Controller Options i MCA 1 A • Wireless Remote Controller Kit (MHK11 with Remote Controller Fan Motor 0.76 F.L A (MRCH1). Wireless Receiver (MIFH1), and cable (MRC1)• Airflow . Setback down to 50 "F when used with MRCH1 Remote Controller I Cooling (Lo - Med - Hi - Powerful) . . 162 - 226 - 381 - 410 Dry CFM - Portable Central Controller (MCCH1 for use with Wireless Remote 144 - 202 - 350 - 367 Wet CFM Controller Kit MHK1)* Heating (Lo - Med - Hi - Powerful) ... .166 - 240 - 399 - 420 Dry CFM Outdoor Air Sensor (MOS1; for use with Remote Controller (MRCH1), Sound Pressure Level Wireless Remote Controller Kit (MHK1) and Portable Central Cooling (Lo - Med - Hi - Powerful) . . 22 - 33 - 43 . 45 dB(A) Controller (MCCH1)' Heating (Lo - Med - Hi - Powerful). 22 - 33 - 43 - 44 dB(A) 'See 5uimstai tor ir$orn rison on each weal DIMENSIONS UNIT INCHES 1 MM 1 Wall- mounted Wired Remote Controller (PAR -21 MAA, req. MAC-3971F) W 31. 71161 799 MA Contact Terminal Interface (MAC- 3971F) D 10-118 / 257 M -NET Control Adapter (MAC- 3991F) H 11-5/8 / 295 Remote Temperature Sensor (M21- JKO.307) Lockdown Bracket for Hand -held Controller (RCMKPI CB) Weight . ... . ... . ........ .... lbs. 1 12 kg External Finish . . .. .. ....Munsell No. 1.0Y 9 2 / 0.2 Cooling' Field Drainpipe Size 0.D. 5 /8" / 15.88 mm Rated Capacity. 12.000 Blu/h Remote Controller ... Wireless Minimum Capacity . 2.800 Blu/h Outdoor Unit SEER ... 23.0 Blu/h/W Total Input. . . 930 W Compressor DC Inverter - driven Twin Rotary MCA... ...... . .....12A Heating at 47° F• Fan Motor . . .. .. . . 0.56 F.L.A Rated Capacity . . 13,600 Blu/h Sound Pressure Level Minimum Capacity .. . 3.000 Btu/h Cooling . . . .48 dB(A) HSPF 10.6 Btu/h/W Heating . 49 dB(A) Total Input. 950W DIMENSIONS INCHES / M M • Heating at 17° P yy 31 Rated Capacity - 7.900 Btu/h Rated Total Input - ... 750 W 0 11 -1/4 / 286 Maximum Capacity. .. ..... . 13.600 Btu /h H 21 -5/8 / 549 Maximum Total Input 1 780 W • Rang Conikimi nor (Cookng) - ulrloor 80°F (27•CI DB. 67°F (19°C) we ouooa 95°F Weight . . . . ..80 lbs. / 36 kg 135°C) DB. 75°F (24°C) w e External Finish .. .. Munsell No. 3.0Y 7.8 / 1 1 (>♦ mag at 47° F)- kfooar 7PF(2 i° k)06. 60° Fl1e •C) AB. Culbor 47°18(1°B Refrigerant Type . R410A (Hear cal1 -Moor 70 60 17°F -eC) 15°F (4,Clvte Refrigerant Pipe Size O.D. Heating at 5° F Gas Side . . 3/8" / 9 52 mm Maximum Capacity ... 12.500 Btu/h Liquid Side. . 1/4" / 6 35 mm Electrical Requirements Max. Refrigerant Pipe Length 65' / 20 m Power Supply ........ .. .... 208 / 230V. 1- Phase, 60 Hz Max Refigerant Pipe Height Difference 40' / 12 m Breaker Size 15 A Connection Method . Flared Voltage Indoor - Outdoor S1 -S2 . AC 208 / 23V )41P I Ispil Indoor - Outdoor S2 -S3 . - .. . ... - DC 12-24V Wireless Remote Controller ... DC to 2011 MITSUBISHI ELECTRIC 6 ELECTRONICS, INC DIMENSIONS: MSZ- FEI2NA -8 & MUZ FE12NA1 MSZ- FEI2NA -8 Unit: inch — — 30 -3/8 -- 7/16 X 1 Oblong hole 7/16 X 13/16 Oblong hole 1/2 ` — ` I —I- 2 -1/2 8 -7/8 :•7I: ti �I.I•l1111■ ,-a- Installation plate ur , _ ____ _ zi6., lei - 11: 13 -•/16 e indoor unit Air in Wall hole e2 -9/16 V 10 1/8 1/4 Installation date n 27 -1116 tf Pi•' ` f...1 -11/16 2-5116 r m �It _ ` 11 - 1 • \ Drain hose a NI Insulation 01.3/8 0.0 f?' - • MI a Liquid hoe 0114 19 - 11/16 (Flared Connection 01/4) - -- Air out 1 .1. a Gas line 03/8 16.15/16 (Flared connection 0318) Dram hose Insulation el -I /6 0 Connected part m5/8 0.0 MUZ -FEI 2NA1 Unit: Inch v 15. 314 - - -.. Dram note 0l.503 . to REQUIRED SPACE Basrceny open 4 inch co more wdhout any obstrurxian ,n Iron! 4 I and on both sides of the unit f ' i Ar M t7 L m r i' N -; q 1 , I I 0 Air out 4- 1.9116 - r— 7/8 2- 3/8 13/76 Oval hole - `` I II , t �� r \ v im ♦+ f /,• ry °br hasidle - it 111111111111111111‘111i11111 lllllllllll 29%32 11 - /4 � IIIIIIIIIIIIIIIIIIIIIIIIIIIIHIIIIIIIIII 1 - 11 Open two sties of led. IIIIII11 IIIIIIIIIIIIIIIIIIIIIIIHIHH III right, or rear side. ! IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII NI a IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII) �, 1111111111111111111111111111111111111111 IIIIIIIIIIIIIIiIIIIIIIIIIIIIIiIIIIIIIIII 04 "1 _i _i - -- - - -. r rid. - .___.- a, I . Liquid pipe 114 (flared) 1. 19.11/16 + - Gas pipe .318 (Oared) - - , — 31.1/2 -f 2 13132 6r23i3 • I MITSUBISHI f ELECTRIC O� CE RTItILD ' 2^ COOLING & HEATING i PARTNER -,..— • '•` F e r t e' 3400 Lawrencevi Su e wanes Rd SUS p ' t Suwanee, GA 30024 I n tertek Tele 678. 376.2900 • Fax 800. 889-9904 Toll Free 800-433-48221003) www mehvac com FORM# MSZ -FE 12NA -8 - MUZ -F E 12NA 1 - 201108 Specifications an subject to change without notice. C 2011 MITSUBISHI ELECTRIC 6 ELECTRONICS INC FLOOR PLAN Two Bedrooms with Two Baths Approx. 987 Sq.Ft. + 98 Sq.Ft. Storage & Patio = 1085 Sq.Ft. Total Living Space Y ^ Bath / H Storage 11 ® r} V r Living a 0 - Room n Q Y Bedroom Patio/ V Deck , Bath 1 ■ Kitchen Iw/n D) Bedroom Dining Room �j /v y '. rao Left Kitchen Floorplan n Bath ® forage uU 0 w W A Livin Bedroom ' Y Room ( \ lath Patio/ / Deck Bedroom [] = Kitchen -- Bntr:. Din 2111 N. • • Room Right Kitchen Floorplan | FRONT • o /v��n� v %..., » ' � � - _ `^ . • _ - ' _ ' '� - - - � `.� ~ '� '~`'�° - —_- :. ---- ' ____--�� ___� - _-_ ` `- . __ _' ° __-__~__- '- ' .. _-__ ___ __ � L. �� ----' ' | ,_ ' __- • -______� ___ ___-_- __-___-� __ � ' � . -__ • ., __-__--__- ^ /' ! B — ---' ., i � _ _ . " ~�� ____. ' y r-- .. -- l ' N� �� � ' n ----- --- -�----- . ~� _ �_-- � . ' '�. �m����� ' `—' . '-------'-- • ��' � _ � �` ^ `^'�N��` ' _ � ' ' _ ��N�� ���__ __ ^'`- _-_____��_��� ,��� t � p __ ` � -_~~____- '_~~_-'_ -�� `����N« ^� �` � ow '` t�r, :-- ' . . " . . • • BACK JO' 11/ a ■-• —. . • . . • . -- • Or . `,---",,Aii‘c. • . • - -...........................--- - - . , -"". - / ' 19 IIP - ••.; As : • :46. ...,-, I n 1 .... 4.1 i . — '"°"'"'"--■--.....--- .. . . . i • . _ . - ..., . .. . _._. i ■ ,, .., . . . i . . .. . . A .. ; - 1 - . , • . . _ . . , , ' •. , _ ........ . . _., . ....i i roi - .--•---.•••- . -, ....•; "ralt,iiisty fill ...:' ..,., ■rafor . ••■• - ' gositaii.:. . . I* — — . -- _. . . . •- .• - 11111111Eglait.:,A.k;. AI. """" t "' AM . - . - - . • ... __ _____ ... .. • . • . . • . . . . . p , ,.. • . • . - . . .,. - . , . . . . . . . . . . . . . . . ✓q ., I v �� B� „.: $0, 3204 0/Np 4 0 Project Plan: Windmill Apartments Ductless Heat Pump Installation pN Submitted by: Jonathan Moscatello, The Heat Pump Store Date: 1/13/12 Address: 10587 SW Tigard St, Tigard, OR 97223 Owners: Jim and Sharon Richards Description: There are 20 identical structures at the property. Each structure is two stories tall, with two apartments on the 4ppro C OF Tr Af� wer level and two on the upper level. SEE ATTACHED FLOOR .onditionally Approved [ PLAN. lee Letter to: Follow r Attached We will install one ductless heat pump system (see attached Omit Nt .. •er: A.4 7 012 • v , ddres ..• ,, , •. ar submittal, Mitsubishi MUZ /MSZ- FE12NA) for each apartment. y: erl Date: 1 '2-- are split systems, with an indoor "head” and an Approved plans outdoor heat pump unit. The indoor and outdoor units are shall be on job site. connected by BUNDLE containing two small refrigerant lines, a power and communications wire, and a condensate drain. OFFICE COPY Installation Plan: I ) 2) OUTDOOR HEAT PUMP UNIT: The outdoor heat pump for each unit will be attached to the wall of each structure, just opposite of the storage unit for each apartment, using a manufacturer approved bracket (see BRACKET submittal, see exterior FRONT and BACK photos). The heat pumps will be installed approximately 12 inches above the ground level. They will be supplied with a 230V single phase electric circuit per the manufacturer's specifications using an outdoor disconnect. INDOOR "HEAD ": The indoor "head" unit for each outdoor heat pump will be attached to the living room wall of each apartment (see FLOOR PLAN). It will be connected to the outdoor unit by a so- called "bundle" of refrigerant lines, power /communications wire, and condensation drain line. The "bundle" will travel along the following pathway: from the outdoor unit, the bundle will travel to the nearest foundation vent, and enter into the crawlspace. The bundle will run through the crawlspace and penetrate into the storage unit through the floor. The bundle will run up the wall of the storage unit inside specialized conduit call "line cover ". At about head height, one of the sets of refrigerant lines, one power /communication wore and condensate drain will penetrate the storage unit wall and terminate at the head in the living room. All connections to the "head" will be made. Again the penetration will be sealed with fire caulk. The remainder of the bundle will continue upward toward the second story and the head in the living room of the upper unit. The remaining items in the bundle will penetrate the ceiling of the lower storage unit, enter the upper unit, and continue to the head for the upper unit. Again, connections will be made and penetrations sealed with fire caulk. Al I t MITSUBISHI ELECTRIC Ire 5 LLO . COOLING & HEATING Split - ductless A/C and Heat Pumps SUBMITTAL DATA: CWMB1.. HEAVY DUTY PAINTED STEEL WALL BRACKETS Job Name: Winmill Apartments Location: Tigard, OR I Date: 1/13/12 Purchaser: The Heat Pump Store Engineer: Submitted to: For LReference ❑Approval ElConstruction System Designation: Schedule No.: GENERAL FEATURES ASSEMBLY INSTRUCTION • The CWMB1 wall brackets are designed to provide a 1 Fit the vertical component to the horizontal arm by means to mount the Mr Slim M- Series. S- Series. P -Series inserting two TEM8X90 screws with four lock washers + and CITY MULTI PUMY - Series outdoor units on a suitable four flat washers + two self - locking nuts into the bracket wall or structure and keep the equipment off the ground components as illustrated The CWMB1 consists of two Independently mounted wall brackets to allow proper leveling and support SELF - LOCKING! WASHERS WASHERS 8X90 SCREWS NUTS • The formed mild carbon steel two piece bracket Is a p rugged. fabricated. heavy duty accessory constructed for x4 �� x8 x0 �? x4 long reliable service life. The bracket is finished with an electrostatically applied, thermally fused acrylic or polyester powder coating for corrosion protecton ro ; x2 • The CWMB1 meets the intent and provides compliance with moo, ,y those codes requiring mounting HVAC equipment above ground level 0 o PLEASE NOTE a The Wall Bracket load capacity can only be assured if the installation is carried out properly (see drawing Ai Drawing B illustrates an improper installation 2 Make sure the chosen installation location meets with specified requirements and wall design and construction is suitable and strong enough to hold the brackets and associated equipment loads Anchors and related mounting 440 lbs • X materials and hardware are the responsibility of the installer 3 Avoid mounting the brackets and attached load on weak wals, soft siding. veneer panels. perforated bricks / blocks or other A insufficient mounting surfaces. h Its the responsibility of the Protect Engineer and /or the Installing Contractor / Dealer to specify furnish, and install a x b any anchor or attachment materials required for the wall construction at the selected mounting location We are not 20.47" x 15.75" responsible for any installation faults or defects. c It is strongly recommended to have the installation periodically inspected by a skilled technician ASSEMBLY Notes: © 2011 MiTSUBISHI ELECTRIC & ELECTRONICS. INC DIMENSIONS: CWMB1 ?' • g a r . • r ) o, r •19 ! i . / � j 1 - r r - v„ot Self ticking tinc plated MB - / Gass BArntpaWcIssee) nut. white(UN174M tcr �f n screw. white, I.E. Mad 54" (.040) 4)11. MBM90' HEAVY DUTY WALL BRACKETS MITSUBISHI ., ELECTRIC COOLING & HEATING PARTNER getter 3400 Lawrenceville Suwanee Rd Suwanee, GA 30024 Tele: 678 -376 -2900 • Fax 800-889 -9904 To Free: 800 - 433 -4822 (#3) www mehvac.00m FORMS C 1- 201108 Spe cifcationsare subject to change without notice. ® 2011 MITSUBISHI ELECTRIC & ELECTRONICS. INC. ar.l & MITSUB ELECTRIC ISHI Ar OM If. SiIIf M. COOLING & HEATING Split -ductless A/C and Heat Pumps SUBMITTAL DATA: MSZ- FE12NA -8 8 MUZ- FE12NA1 12.000 BTUiH WALL - MOUNTED HEAT PUMP SYSTEM Job Name: Windmill Apartments Location:Tigard, OR I Date: 1/13/12 Purchaser: The Heat Pump Store Engineer: Submitted to: For ❑Reference ❑Approval ❑Construction System Designation: Schedule No.: GENERAL FEATURES • Highly energy - efficient system that features 92% heating capacity at 5'F. 75% at -4"F, and 58% at -13`F • Updated sleek, compact indoor unit design f lleo n'"1. -...: r, • Includes Standard. Platinum Deodorizing, and Anti- allergy En- gailtallSailliF • zyme filters for a complete air purifying system Powerful Mode function permits system to temporarily run at - a lower/higher temperature with an increased fan speed, which indoor unit MSZ- FEI2NA -8 quickly brings the room to the optimum comfort level • Integrated i -see Sensor automatically adjusts the unit's operation according to temperature differences detected between the floor ' so and the intake air- ensuring w.e comfort and energy usage Ccotriger • Hand -held WIreless Remote oController e Outdoor Lint MU2 fE12NA1 • Base heater is available as an option • Limited warranty: five years on parts and defects and seven OPERATING RANGE years on compressors OPTIONAL ACCESSORIES Irmo "* ' " " T. 010001 "' a ' A°Ta '" p Outdoor Unit Mnmum 90°F (32•C) 08 73°F (23•C) vie 115°F 14e•ci De cooing • Base Heater (MAC- 640BH -U1 Mmn um 97•F (19°Ci 08.57 (14 •C u9 14°F - 06 Drain Socket (MAC -851 DS) Marnnum ear (27°C) 06 67°F (19°C) 'AB 75°F (24°C) D8 65•F 18°C 1AL' Indoor Unit " "`.° sun,,,,,, 70°F (21°C) 08 60°F 16°C; AS -13°F r -25•0) Da. -15°F t26.0 NB" Condensate Pump (513100-230, 230V) •• slalom ass 4 al -19•F (-28°C1 lo aria toe rnstor error an rrxcvera from c,W 4 Replacement Platinum Deodonzing Filter (MAC- 308FT) operaeon am/ astomaticaay restarts at- 13°F1-25°C) Replacement Anti - allergy Enzyme Filter (MAC4418FT. MERV 8) Indoor Unit Controller Options i MCA 1 A • Wireless Remote Controller Kit (MHK11 with Remote Controller Fan Motor 0.76 F.L A (MRCH1). Wireless Receiver (MIFH1), and cable (MRC1)• Airflow . Setback down to 50 "F when used with MRCH1 Remote Controller I Cooling (Lo - Med - Hi - Powerful) . . 162 - 226 - 381 - 410 Dry CFM - Portable Central Controller (MCCH1 for use with Wireless Remote 144 - 202 - 350 - 367 Wet CFM Controller Kit MHK1)* Heating (Lo - Med - Hi - Powerful) ... .166 - 240 - 399 - 420 Dry CFM Outdoor Air Sensor (MOS1; for use with Remote Controller (MRCH1), Sound Pressure Level Wireless Remote Controller Kit (MHK1) and Portable Central Cooling (Lo - Med - Hi - Powerful) . . 22 - 33 - 43 . 45 dB(A) Controller (MCCH1)' Heating (Lo - Med - Hi - Powerful). 22 - 33 - 43 - 44 dB(A) 'See 5uimstai tor ir$orn rison on each weal DIMENSIONS UNIT INCHES 1 MM 1 Wall- mounted Wired Remote Controller (PAR -21 MAA, req. MAC-3971F) W 31. 71161 799 MA Contact Terminal Interface (MAC- 3971F) D 10-118 / 257 M -NET Control Adapter (MAC- 3991F) H 11-5/8 / 295 Remote Temperature Sensor (M21- JKO.307) Lockdown Bracket for Hand -held Controller (RCMKPI CB) Weight . ... . ... . ........ .... lbs. 1 12 kg External Finish . . .. .. ....Munsell No. 1.0Y 9 2 / 0.2 Cooling' Field Drainpipe Size 0.D. 5 /8" / 15.88 mm Rated Capacity. 12.000 Blu/h Remote Controller ... Wireless Minimum Capacity . 2.800 Blu/h Outdoor Unit SEER ... 23.0 Blu/h/W Total Input. . . 930 W Compressor DC Inverter - driven Twin Rotary MCA... ...... . .....12A Heating at 47° F• Fan Motor . . .. .. . . 0.56 F.L.A Rated Capacity . . 13,600 Blu/h Sound Pressure Level Minimum Capacity .. . 3.000 Btu/h Cooling . . . .48 dB(A) HSPF 10.6 Btu/h/W Heating . 49 dB(A) Total Input. 950W DIMENSIONS INCHES / M M • Heating at 17° P yy 31 Rated Capacity - 7.900 Btu/h Rated Total Input - ... 750 W 0 11 -1/4 / 286 Maximum Capacity. .. ..... . 13.600 Btu /h H 21 -5/8 / 549 Maximum Total Input 1 780 W • Rang Conikimi nor (Cookng) - ulrloor 80°F (27•CI DB. 67°F (19°C) we ouooa 95°F Weight . . . . ..80 lbs. / 36 kg 135°C) DB. 75°F (24°C) w e External Finish .. .. Munsell No. 3.0Y 7.8 / 1 1 (>♦ mag at 47° F)- kfooar 7PF(2 i° k)06. 60° Fl1e •C) AB. Culbor 47°18(1°B Refrigerant Type . R410A (Hear cal1 -Moor 70 60 17°F -eC) 15°F (4,Clvte Refrigerant Pipe Size O.D. Heating at 5° F Gas Side . . 3/8" / 9 52 mm Maximum Capacity ... 12.500 Btu/h Liquid Side. . 1/4" / 6 35 mm Electrical Requirements Max. Refrigerant Pipe Length 65' / 20 m Power Supply ........ .. .... 208 / 230V. 1- Phase, 60 Hz Max Refigerant Pipe Height Difference 40' / 12 m Breaker Size 15 A Connection Method . Flared Voltage Indoor - Outdoor S1 -S2 . AC 208 / 23V )41P I Ispil Indoor - Outdoor S2 -S3 . - .. . ... - DC 12-24V Wireless Remote Controller ... DC to 2011 MITSUBISHI ELECTRIC 6 ELECTRONICS, INC DIMENSIONS: MSZ- FEI2NA -8 & MUZ FE12NA1 MSZ- FEI2NA -8 Unit: inch — — 30 -3/8 -- 7/16 X 1 Oblong hole 7/16 X 13/16 Oblong hole 1/2 ` — ` I —I- 2 -1/2 8 -7/8 :•7I: ti �I.I•l1111■ ,-a- Installation plate ur , _ ____ _ zi6., lei - 11: 13 -•/16 e indoor unit Air in Wall hole e2 -9/16 V 10 1/8 1/4 Installation date n 27 -1116 tf Pi•' ` f...1 -11/16 2-5116 r m �It _ ` 11 - 1 • \ Drain hose a NI Insulation 01.3/8 0.0 f?' - • MI a Liquid hoe 0114 19 - 11/16 (Flared Connection 01/4) - -- Air out 1 .1. a Gas line 03/8 16.15/16 (Flared connection 0318) Dram hose Insulation el -I /6 0 Connected part m5/8 0.0 MUZ -FEI 2NA1 Unit: Inch v 15. 314 - - -.. Dram note 0l.503 . to REQUIRED SPACE Basrceny open 4 inch co more wdhout any obstrurxian ,n Iron! 4 I and on both sides of the unit f ' i Ar M t7 L m r i' N -; q 1 , I I 0 Air out 4- 1.9116 - r— 7/8 2- 3/8 13/76 Oval hole - `` I II , t �� r \ v im ♦+ f /,• ry °br hasidle - it 111111111111111111‘111i11111 lllllllllll 29%32 11 - /4 � IIIIIIIIIIIIIIIIIIIIIIIIIIIIHIIIIIIIIII 1 - 11 Open two sties of led. IIIIII11 IIIIIIIIIIIIIIIIIIIIIIIHIHH III right, or rear side. ! IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII NI a IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII) �, 1111111111111111111111111111111111111111 IIIIIIIIIIIIIIiIIIIIIIIIIIIIIiIIIIIIIIII 04 "1 _i _i - -- - - -. r rid. - .___.- a, I . Liquid pipe 114 (flared) 1. 19.11/16 + - Gas pipe .318 (Oared) - - , — 31.1/2 -f 2 13132 6r23i3 • I MITSUBISHI f ELECTRIC O� CE RTItILD ' 2^ COOLING & HEATING i PARTNER -,..— • '•` F e r t e' 3400 Lawrencevi Su e wanes Rd SUS p ' t Suwanee, GA 30024 I n tertek Tele 678. 376.2900 • Fax 800. 889-9904 Toll Free 800-433-48221003) www mehvac com FORM# MSZ -FE 12NA -8 - MUZ -F E 12NA 1 - 201108 Specifications an subject to change without notice. C 2011 MITSUBISHI ELECTRIC 6 ELECTRONICS INC FLOOR PLAN Two Bedrooms with Two Baths Approx. 987 Sq.Ft. + 98 Sq.Ft. Storage & Patio = 1085 Sq.Ft. Total Living Space Y ^ Bath / H Storage 11 ® r} V r Living a 0 - Room n Q Y Bedroom Patio/ V Deck , Bath 1 ■ Kitchen Iw/n D) Bedroom Dining Room �j /v y '. rao Left Kitchen Floorplan n Bath ® forage uU 0 w W A Livin Bedroom ' Y Room ( \ lath Patio/ / Deck Bedroom [] = Kitchen -- Bntr:. Din 2111 N. • • Room Right Kitchen Floorplan | FRONT • o /v��n� v %..., » ' � � - _ `^ . • _ - ' _ ' '� - - - � `.� ~ '� '~`'�° - —_- :. ---- ' ____--�� ___� - _-_ ` `- . __ _' ° __-__~__- '- ' .. _-__ ___ __ � L. �� ----' ' | ,_ ' __- • -______� ___ ___-_- __-___-� __ � ' � . -__ • ., __-__--__- ^ /' ! B — ---' ., i � _ _ . " ~�� ____. ' y r-- .. -- l ' N� �� � ' n ----- --- -�----- . ~� _ �_-- � . ' '�. �m����� ' `—' . '-------'-- • ��' � _ � �` ^ `^'�N��` ' _ � ' ' _ ��N�� ���__ __ ^'`- _-_____��_��� ,��� t � p __ ` � -_~~____- '_~~_-'_ -�� `����N« ^� �` � ow '` t�r, :-- ' . . " . . • • BACK JO' 11/ a ■-• —. . • . . • . -- • Or . `,---",,Aii‘c. • . • - -...........................--- - - . , -"". - / ' 19 IIP - ••.; As : • :46. ...,-, I n 1 .... 4.1 i . — '"°"'"'"--■--.....--- .. . . . i • . _ . - ..., . .. . _._. i ■ ,, .., . . . i . . .. . . A .. ; - 1 - . , • . . _ . . , , ' •. , _ ........ . . _., . ....i i roi - .--•---.•••- . -, ....•; "ralt,iiisty fill ...:' ..,., ■rafor . ••■• - ' gositaii.:. . . I* — — . -- _. . . . •- .• - 11111111Eglait.:,A.k;. AI. """" t "' AM . - . - - . • ... __ _____ ... .. • . • . . • . . . . . p , ,.. • . • . - . . .,. - . , . . . . . . . . . . . . . . . ✓q ., I v �� B� „.: $0, 3204 0/Np 4 0 Project Plan: Windmill Apartments Ductless Heat Pump Installation pN Submitted by: Jonathan Moscatello, The Heat Pump Store Date: 1/13/12 Address: 10587 SW Tigard St, Tigard, OR 97223 Owners: Jim and Sharon Richards Description: There are 20 identical structures at the property. Each structure is two stories tall, with two apartments on the 4ppro C OF Tr Af� wer level and two on the upper level. SEE ATTACHED FLOOR .onditionally Approved [ PLAN. lee Letter to: Follow r Attached We will install one ductless heat pump system (see attached Omit Nt .. •er: A.4 7 012 • v , ddres ..• ,, , •. ar submittal, Mitsubishi MUZ /MSZ- FE12NA) for each apartment. y: erl Date: 1 '2-- are split systems, with an indoor "head” and an Approved plans outdoor heat pump unit. The indoor and outdoor units are shall be on job site. connected by BUNDLE containing two small refrigerant lines, a power and communications wire, and a condensate drain. OFFICE COPY Installation Plan: I ) 2) OUTDOOR HEAT PUMP UNIT: The outdoor heat pump for each unit will be attached to the wall of each structure, just opposite of the storage unit for each apartment, using a manufacturer approved bracket (see BRACKET submittal, see exterior FRONT and BACK photos). The heat pumps will be installed approximately 12 inches above the ground level. They will be supplied with a 230V single phase electric circuit per the manufacturer's specifications using an outdoor disconnect. INDOOR "HEAD ": The indoor "head" unit for each outdoor heat pump will be attached to the living room wall of each apartment (see FLOOR PLAN). It will be connected to the outdoor unit by a so- called "bundle" of refrigerant lines, power /communications wire, and condensation drain line. The "bundle" will travel along the following pathway: from the outdoor unit, the bundle will travel to the nearest foundation vent, and enter into the crawlspace. The bundle will run through the crawlspace and penetrate into the storage unit through the floor. The bundle will run up the wall of the storage unit inside specialized conduit call "line cover ". At about head height, one of the sets of refrigerant lines, one power /communication wore and condensate drain will penetrate the storage unit wall and terminate at the head in the living room. All connections to the "head" will be made. Again the penetration will be sealed with fire caulk. The remainder of the bundle will continue upward toward the second story and the head in the living room of the upper unit. The remaining items in the bundle will penetrate the ceiling of the lower storage unit, enter the upper unit, and continue to the head for the upper unit. Again, connections will be made and penetrations sealed with fire caulk. Al I t MITSUBISHI ELECTRIC Ire 5 LLO . COOLING & HEATING Split - ductless A/C and Heat Pumps SUBMITTAL DATA: CWMB1.. HEAVY DUTY PAINTED STEEL WALL BRACKETS Job Name: Winmill Apartments Location: Tigard, OR I Date: 1/13/12 Purchaser: The Heat Pump Store Engineer: Submitted to: For LReference ❑Approval ElConstruction System Designation: Schedule No.: GENERAL FEATURES ASSEMBLY INSTRUCTION • The CWMB1 wall brackets are designed to provide a 1 Fit the vertical component to the horizontal arm by means to mount the Mr Slim M- Series. S- Series. P -Series inserting two TEM8X90 screws with four lock washers + and CITY MULTI PUMY - Series outdoor units on a suitable four flat washers + two self - locking nuts into the bracket wall or structure and keep the equipment off the ground components as illustrated The CWMB1 consists of two Independently mounted wall brackets to allow proper leveling and support SELF - LOCKING! WASHERS WASHERS 8X90 SCREWS NUTS • The formed mild carbon steel two piece bracket Is a p rugged. fabricated. heavy duty accessory constructed for x4 �� x8 x0 �? x4 long reliable service life. The bracket is finished with an electrostatically applied, thermally fused acrylic or polyester powder coating for corrosion protecton ro ; x2 • The CWMB1 meets the intent and provides compliance with moo, ,y those codes requiring mounting HVAC equipment above ground level 0 o PLEASE NOTE a The Wall Bracket load capacity can only be assured if the installation is carried out properly (see drawing Ai Drawing B illustrates an improper installation 2 Make sure the chosen installation location meets with specified requirements and wall design and construction is suitable and strong enough to hold the brackets and associated equipment loads Anchors and related mounting 440 lbs • X materials and hardware are the responsibility of the installer 3 Avoid mounting the brackets and attached load on weak wals, soft siding. veneer panels. perforated bricks / blocks or other A insufficient mounting surfaces. h Its the responsibility of the Protect Engineer and /or the Installing Contractor / Dealer to specify furnish, and install a x b any anchor or attachment materials required for the wall construction at the selected mounting location We are not 20.47" x 15.75" responsible for any installation faults or defects. c It is strongly recommended to have the installation periodically inspected by a skilled technician ASSEMBLY Notes: © 2011 MiTSUBISHI ELECTRIC & ELECTRONICS. INC DIMENSIONS: CWMB1 ?' • g a r . • r ) o, r •19 ! i . / � j 1 - r r - v„ot Self ticking tinc plated MB - / Gass BArntpaWcIssee) nut. white(UN174M tcr �f n screw. white, I.E. Mad 54" (.040) 4)11. MBM90' HEAVY DUTY WALL BRACKETS MITSUBISHI ., ELECTRIC COOLING & HEATING PARTNER getter 3400 Lawrenceville Suwanee Rd Suwanee, GA 30024 Tele: 678 -376 -2900 • Fax 800-889 -9904 To Free: 800 - 433 -4822 (#3) www mehvac.00m FORMS C 1- 201108 Spe cifcationsare subject to change without notice. ® 2011 MITSUBISHI ELECTRIC & ELECTRONICS. INC. ar.l & MITSUB ELECTRIC ISHI Ar OM If. SiIIf M. COOLING & HEATING Split -ductless A/C and Heat Pumps SUBMITTAL DATA: MSZ- FE12NA -8 8 MUZ- FE12NA1 12.000 BTUiH WALL - MOUNTED HEAT PUMP SYSTEM Job Name: Windmill Apartments Location:Tigard, OR I Date: 1/13/12 Purchaser: The Heat Pump Store Engineer: Submitted to: For ❑Reference ❑Approval ❑Construction System Designation: Schedule No.: GENERAL FEATURES • Highly energy - efficient system that features 92% heating capacity at 5'F. 75% at -4"F, and 58% at -13`F • Updated sleek, compact indoor unit design f lleo n'"1. -...: r, • Includes Standard. Platinum Deodorizing, and Anti- allergy En- gailtallSailliF • zyme filters for a complete air purifying system Powerful Mode function permits system to temporarily run at - a lower/higher temperature with an increased fan speed, which indoor unit MSZ- FEI2NA -8 quickly brings the room to the optimum comfort level • Integrated i -see Sensor automatically adjusts the unit's operation according to temperature differences detected between the floor ' so and the intake air- ensuring w.e comfort and energy usage Ccotriger • Hand -held WIreless Remote oController e Outdoor Lint MU2 fE12NA1 • Base heater is available as an option • Limited warranty: five years on parts and defects and seven OPERATING RANGE years on compressors OPTIONAL ACCESSORIES Irmo "* ' " " T. 010001 "' a ' A°Ta '" p Outdoor Unit Mnmum 90°F (32•C) 08 73°F (23•C) vie 115°F 14e•ci De cooing • Base Heater (MAC- 640BH -U1 Mmn um 97•F (19°Ci 08.57 (14 •C u9 14°F - 06 Drain Socket (MAC -851 DS) Marnnum ear (27°C) 06 67°F (19°C) 'AB 75°F (24°C) D8 65•F 18°C 1AL' Indoor Unit " "`.° sun,,,,,, 70°F (21°C) 08 60°F 16°C; AS -13°F r -25•0) Da. -15°F t26.0 NB" Condensate Pump (513100-230, 230V) •• slalom ass 4 al -19•F (-28°C1 lo aria toe rnstor error an rrxcvera from c,W 4 Replacement Platinum Deodonzing Filter (MAC- 308FT) operaeon am/ astomaticaay restarts at- 13°F1-25°C) Replacement Anti - allergy Enzyme Filter (MAC4418FT. MERV 8) Indoor Unit Controller Options i MCA 1 A • Wireless Remote Controller Kit (MHK11 with Remote Controller Fan Motor 0.76 F.L A (MRCH1). Wireless Receiver (MIFH1), and cable (MRC1)• Airflow . Setback down to 50 "F when used with MRCH1 Remote Controller I Cooling (Lo - Med - Hi - Powerful) . . 162 - 226 - 381 - 410 Dry CFM - Portable Central Controller (MCCH1 for use with Wireless Remote 144 - 202 - 350 - 367 Wet CFM Controller Kit MHK1)* Heating (Lo - Med - Hi - Powerful) ... .166 - 240 - 399 - 420 Dry CFM Outdoor Air Sensor (MOS1; for use with Remote Controller (MRCH1), Sound Pressure Level Wireless Remote Controller Kit (MHK1) and Portable Central Cooling (Lo - Med - Hi - Powerful) . . 22 - 33 - 43 . 45 dB(A) Controller (MCCH1)' Heating (Lo - Med - Hi - Powerful). 22 - 33 - 43 - 44 dB(A) 'See 5uimstai tor ir$orn rison on each weal DIMENSIONS UNIT INCHES 1 MM 1 Wall- mounted Wired Remote Controller (PAR -21 MAA, req. MAC-3971F) W 31. 71161 799 MA Contact Terminal Interface (MAC- 3971F) D 10-118 / 257 M -NET Control Adapter (MAC- 3991F) H 11-5/8 / 295 Remote Temperature Sensor (M21- JKO.307) Lockdown Bracket for Hand -held Controller (RCMKPI CB) Weight . ... . ... . ........ .... lbs. 1 12 kg External Finish . . .. .. ....Munsell No. 1.0Y 9 2 / 0.2 Cooling' Field Drainpipe Size 0.D. 5 /8" / 15.88 mm Rated Capacity. 12.000 Blu/h Remote Controller ... Wireless Minimum Capacity . 2.800 Blu/h Outdoor Unit SEER ... 23.0 Blu/h/W Total Input. . . 930 W Compressor DC Inverter - driven Twin Rotary MCA... ...... . .....12A Heating at 47° F• Fan Motor . . .. .. . . 0.56 F.L.A Rated Capacity . . 13,600 Blu/h Sound Pressure Level Minimum Capacity .. . 3.000 Btu/h Cooling . . . .48 dB(A) HSPF 10.6 Btu/h/W Heating . 49 dB(A) Total Input. 950W DIMENSIONS INCHES / M M • Heating at 17° P yy 31 Rated Capacity - 7.900 Btu/h Rated Total Input - ... 750 W 0 11 -1/4 / 286 Maximum Capacity. .. ..... . 13.600 Btu /h H 21 -5/8 / 549 Maximum Total Input 1 780 W • Rang Conikimi nor (Cookng) - ulrloor 80°F (27•CI DB. 67°F (19°C) we ouooa 95°F Weight . . . . ..80 lbs. / 36 kg 135°C) DB. 75°F (24°C) w e External Finish .. .. Munsell No. 3.0Y 7.8 / 1 1 (>♦ mag at 47° F)- kfooar 7PF(2 i° k)06. 60° Fl1e •C) AB. Culbor 47°18(1°B Refrigerant Type . R410A (Hear cal1 -Moor 70 60 17°F -eC) 15°F (4,Clvte Refrigerant Pipe Size O.D. Heating at 5° F Gas Side . . 3/8" / 9 52 mm Maximum Capacity ... 12.500 Btu/h Liquid Side. . 1/4" / 6 35 mm Electrical Requirements Max. Refrigerant Pipe Length 65' / 20 m Power Supply ........ .. .... 208 / 230V. 1- Phase, 60 Hz Max Refigerant Pipe Height Difference 40' / 12 m Breaker Size 15 A Connection Method . Flared Voltage Indoor - Outdoor S1 -S2 . AC 208 / 23V )41P I Ispil Indoor - Outdoor S2 -S3 . - .. . ... - DC 12-24V Wireless Remote Controller ... DC to 2011 MITSUBISHI ELECTRIC 6 ELECTRONICS, INC DIMENSIONS: MSZ- FEI2NA -8 & MUZ FE12NA1 MSZ- FEI2NA -8 Unit: inch — — 30 -3/8 -- 7/16 X 1 Oblong hole 7/16 X 13/16 Oblong hole 1/2 ` — ` I —I- 2 -1/2 8 -7/8 :•7I: ti �I.I•l1111■ ,-a- Installation plate ur , _ ____ _ zi6., lei - 11: 13 -•/16 e indoor unit Air in Wall hole e2 -9/16 V 10 1/8 1/4 Installation date n 27 -1116 tf Pi•' ` f...1 -11/16 2-5116 r m �It _ ` 11 - 1 • \ Drain hose a NI Insulation 01.3/8 0.0 f?' - • MI a Liquid hoe 0114 19 - 11/16 (Flared Connection 01/4) - -- Air out 1 .1. a Gas line 03/8 16.15/16 (Flared connection 0318) Dram hose Insulation el -I /6 0 Connected part m5/8 0.0 MUZ -FEI 2NA1 Unit: Inch v 15. 314 - - -.. Dram note 0l.503 . to REQUIRED SPACE Basrceny open 4 inch co more wdhout any obstrurxian ,n Iron! 4 I and on both sides of the unit f ' i Ar M t7 L m r i' N -; q 1 , I I 0 Air out 4- 1.9116 - r— 7/8 2- 3/8 13/76 Oval hole - `` I II , t �� r \ v im ♦+ f /,• ry °br hasidle - it 111111111111111111‘111i11111 lllllllllll 29%32 11 - /4 � IIIIIIIIIIIIIIIIIIIIIIIIIIIIHIIIIIIIIII 1 - 11 Open two sties of led. IIIIII11 IIIIIIIIIIIIIIIIIIIIIIIHIHH III right, or rear side. ! IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII NI a IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII) �, 1111111111111111111111111111111111111111 IIIIIIIIIIIIIIiIIIIIIIIIIIIIIiIIIIIIIIII 04 "1 _i _i - -- - - -. r rid. - .___.- a, I . Liquid pipe 114 (flared) 1. 19.11/16 + - Gas pipe .318 (Oared) - - , — 31.1/2 -f 2 13132 6r23i3 • I MITSUBISHI f ELECTRIC O� CE RTItILD ' 2^ COOLING & HEATING i PARTNER -,..— • '•` F e r t e' 3400 Lawrencevi Su e wanes Rd SUS p ' t Suwanee, GA 30024 I n tertek Tele 678. 376.2900 • Fax 800. 889-9904 Toll Free 800-433-48221003) www mehvac com FORM# MSZ -FE 12NA -8 - MUZ -F E 12NA 1 - 201108 Specifications an subject to change without notice. C 2011 MITSUBISHI ELECTRIC 6 ELECTRONICS INC FLOOR PLAN Two Bedrooms with Two Baths Approx. 987 Sq.Ft. + 98 Sq.Ft. Storage & Patio = 1085 Sq.Ft. Total Living Space Y ^ Bath / H Storage 11 ® r} V r Living a 0 - Room n Q Y Bedroom Patio/ V Deck , Bath 1 ■ Kitchen Iw/n D) Bedroom Dining Room �j /v y '. rao Left Kitchen Floorplan n Bath ® forage uU 0 w W A Livin Bedroom ' Y Room ( \ lath Patio/ / Deck Bedroom [] = Kitchen -- Bntr:. Din 2111 N. • • Room Right Kitchen Floorplan | FRONT • o /v��n� v %..., » ' � � - _ `^ . • _ - ' _ ' '� - - - � `.� ~ '� '~`'�° - —_- :. ---- ' ____--�� ___� - _-_ ` `- . __ _' ° __-__~__- '- ' .. _-__ ___ __ � L. �� ----' ' | ,_ ' __- • -______� ___ ___-_- __-___-� __ � ' � . -__ • ., __-__--__- ^ /' ! B — ---' ., i � _ _ . " ~�� ____. ' y r-- .. -- l ' N� �� � ' n ----- --- -�----- . ~� _ �_-- � . ' '�. �m����� ' `—' . '-------'-- • ��' � _ � �` ^ `^'�N��` ' _ � ' ' _ ��N�� ���__ __ ^'`- _-_____��_��� ,��� t � p __ ` � -_~~____- '_~~_-'_ -�� `����N« ^� �` � ow '` t�r, :-- ' . . " . . • • BACK JO' 11/ a ■-• —. . • . . • . -- • Or . `,---",,Aii‘c. • . • - -...........................--- - - . , -"". - / ' 19 IIP - ••.; As : • :46. ...,-, I n 1 .... 4.1 i . — '"°"'"'"--■--.....--- .. . . . i • . _ . - ..., . .. . _._. i ■ ,, .., . . . i . . .. . . A .. ; - 1 - . , • . . _ . . , , ' •. , _ ........ . . _., . ....i i roi - .--•---.•••- . -, ....•; "ralt,iiisty fill ...:' ..,., ■rafor . ••■• - ' gositaii.:. . . I* — — . -- _. . . . •- .• - 11111111Eglait.:,A.k;. AI. """" t "' AM . - . - - . • ... __ _____ ... .. • . • . . • . . . . . p , ,.. • . • . - . . .,. - . , . . . . . . . . . . . . . . .