Report r 1 -7 Documentation 43 lation wiring has been checked. Part 3 shall be completed The Record of Completion was previously referred to after the operational acceptance tests have been completed. as the Certificate of Completion. This document is very A preliminary copy of the record of completion shall be given important to the owner, maintainer and the authority to the system owner and, where-requested, to other authori having jurisdiction because it provides information nec- ties having jurisdiction after completion of the installation wir- essary to maintain, repair and modify the system. A ing tests, and a final copy shall be provided after completion record of completion is required for all installed fire of the operational acceptance tests. Alarm Systems. n Record of Completion Name of Protected Property: P,9 77 uj S Address: l 6 ®.5 S Gi 7� n ci 4%/e-- Rep. of Protected Prop. (name /phone): Authority Having Jurisdiction: r, Q Arc/ Address /Phone Number: J Type(s) of System or Service NFPA 72, Chapter 3 — Local If alarm is transmitted to location(s) off premises, list where received: �y c e rlfrfi Si -, fi n TOOn;4 n3 7 ' `7 - OD) NFPA 72, Chapter 3 — Emergency Voice /Alarm Service Quantity of voice /alarm channels: Single: Multiple: Quantity of speakers installed: Quantity of speaker zones: Quantity of telephones or telephone jacks included in system: NFPA 72, Chapter 4 — Auxiliary Indicate type of connection: Local energy: Shunt: Parallel telephone: Location and leleohone number for receipt of signals: NiFI)er_v ; Ile , q? ?- gqq -odai NFPA 72, Chapter 4 — Remote Station �j Alarm: enfr /9 I S1f' ion T0400;1-011, n�i 0 77 �j q D l - ���� Supervisory: 1 1 J NFPA 72. Chapter 4 — Proprietary II alarms are retransmitted to public fire service communications center or others, indicate location and telephone number of the organization receiving alarm: Center »l 519hoI rr)o a rms Indicate how alarm is retransmitted: NFPA 72. Chapter 4 — Central Station / 1 The Prime Contractor: C e n 1 { S 1//T /O/1 7 1 On / O� n 4 Central Station Location: �� n env, I -T Ile , �L � L. Figure 1 -7.2.1 Record of Completion. NATIONAL FIRE ALARM CODE HANDBOOK 44 Chapter 1: Fundamentals of Fire Alarm Systems Means of transmission of signals from the protected premises to the central station: McCulloh Multiplex One -Way Radio ✓ Digital Alarm Communicator Two -Way Radio Others Means of transmission of alarms to the public lire service communications center: (a) C en7L!'/?/ S1-,91 Operni - 0 (b) System Location: , A49 €!_N.V. r,1 / Organization Name /Phone Representative Name /Phone Installer > ley L( /-'; / DB ;cQ 7ria>^F1vrk Se)3'5/9 53t Supplier Service Organization_ $19" n- I e, y S � l f7)2 Location of Record (As- Built) Drawings: / {� S, 9 lei k ( OP I ) Location of Owners Manuals: d n S; 1 Location of Test Reports: On 5'; fe A contr r" cigted , forlestandinspectioninaccordancewithNFPAstandard (s)No(s). dated in effect. Record of System Installation (Fill out after installation is complete and wiring checked for opens, shorts, ground faults, and improper branching, but prior to conducting op- erational acceptance tests.) This system has installed in accordance with the NFPA standards as shown below, was inspected by �JgV ;c1 � ` ���t r on 7 / 47 /� includes the devices shown below, and has been in service since /11 ? ` - NFPA 72, Chapters 1 3 4 5 6 7 (circle all that apply) NFPA 70, National Electrical Code, Article 760 Manufacturer's Instructions OtXr (specify): Signed: Cc �+r r / i : • ,( Date: Organization: _ T, r) / e y Se can / /y _ 3. Record of System Operation /� / L All operational features and functions of this system were tested by. &V ;C / )al'A ,, I` on , and found to be operating properly in accordance with the requirements of: V NFPA 72, Chapters 1 3 4 5 6 7 (circle all That apply) NFPA 70, National Electrical Code, Article 760 V Manufacturer's Instructions Ot r (specify): f Signed: liA -Lt /� 2fc,L Date: Organization: T//3 n 1 ey Sec u r l . . ' J/ y Figure 1 -7.2.1 Continued NATIONAL FIRE ALARM CODE HANDBOOK 1 -7 Documentation 45 4. Alarm- Initiating Devices and Circuits (use blanks to indicate quantity of devices) MANUAL (a) / Manual Stations Noncoded, Activating Transmitters Coded (b) Combination Manual Fire Alarm and Guard's Tour Coded Stations AUTOMATIC Coverage: Complete: Partial: (a) S Smoke Detectors Ion Photo (b) Duct Detectors Ion Photo (c) / Heat Detectors FT RR FT /RR RC (d) Sprinkler Water(low Switches: Transmitters Noncoded, Activating Coded (e) Other (list): 5. Supervisory Signal- Initiating Devices and Circuits (use blanks to indicate quantity of devices) GUARD'S TOUR (a) Coded Stations (b) Noncoded Stations, Activating Transmitters (c) Compulsory Guard Tour System Comprised of Transmitter Stations and Intermediate Stations NOTE: Combination devices recorded under 4(b) and 5(a). SPRINKLER SYSTEM (a) Coded Valve Supervisory Signaling Attachments • Valve Supervisory Switches, Activating Transmitters • (b) Building Temperature Points (c) Site Water Temperature Points (d) Site Water Supply Level Points Electric Fire Pump: (e) Fire Pump Power (I) Fire Pump Running (g) Phase Reversal Engine- Driven Fire Pump: (h) Selector in Auto Position (i) Engine or Control Panel Trouble (I) Fire Pump Running Engine- Driven Generator: (k) Selector in Auto Position (I) Control Panel Trouble (m) Transfer Switches (n) Engine Running Other Supervisory Function(s) (specify): Figure 1 -7.2.1 Continued NATIONAL FIRE ALARM CODE HANDBOOK 46 Chapter 1: Fundamentals of Are Alarm Systems 6. Alarm Notification Appliances and Circuits Quantity of indicating appliance circuits connected to the system: Types and quantities of alarm indicating appliances installed: (a) Bells Inch (b) Speakers (c) Horns (d) - Chimes (e) Other: !/ (I) 9 Visual Signals Type: f TG I'n /5 d6e5" 1 4 with audible w/o audible (9) Local Annunciator 7. Signaling Line Circuits Quantity and Style (see NFPA 72, Table 3 -6) of signaling line circuits connected to system: Quantity: 42_ Style: 8. System Power Supplies (a) Primary (Main):Nominal Voltage: / 2 L) V Current Rating: /,111 Overcurrent Protection: Type: f A — C r Current Rating: 020 A 1')1/0 Location: (b) Secondary (Standby): / Storage Battery: Amp-Hour Rating (�j9/v) ) £Q i T L /90 Calculated capacity to drive system, in hours: / •24 60 Engine- driven generator dedicated to fire alarm system: Location of fuel storage: (c) Emergency or Standby System used as backup to Primary Power Supply, instead of using a Secondary Power Supply: Emergency System described in NFPA 70, Article 700 Legally Required Standby System described in NFPA 70, Article 701 Optional Standby System described in NFPA 70, Article 702, which also meets the performance requirements of Article 700 or 701 9. System Software (a) Operating System Software Revision Level(s): (b) Application Software Revision Level(s): (c) Revision Completed by: (name) (firm) 10. Comments: l9at A / ,56rv T (signed) for Central Station or Alarm Service Company (title) ) (date) Figure 1 -7.2.1 Continued NATIONAL FIRE ALARM CODE HANDBOOK 1 -7 Documentation 47 Fre of routine tests and inspectionss if other than in accordance with the referenced NFPA standards(s): .J �_ �, - -_ / t` 51—ed !'cJ c 4 h �o Ce n frA l Si/if on A G l-0.9 0 1 e _ P J System deviations from the referenced NFPA standard(s) are: /V19 A — _ — (signed) for Central Station or Alarm Service Company (title) (date) Upon completion of the system(s) satisfactory lest(s) witnessed (if required by the authority having jurisdiction): frZattej — - -- — Ser ce Teel) -- — — - -- (signed) for Central Station or Alarm Service Company (title) (dale) Figure 1 -7.2.1 • A-1-7.2.1 The requirements of Chapter 7 should be used 2. Step -by -step instructions detailing the requisite test - to perform the installation wiring and operational acceptance ing and maintenance procedures. and the intervals at which tests required when completing the record of completion. these procedures shall be performed. for each type of device installed; 1-7.2.2 Every system shall include the following documen- 3. A schedule that correlates the testing and mainte- tation, which shall be delivered to the owner or the owner's nance procedures recommended by A- 1- 7.2.2(c)2 with the listing recommended by A- 1- 7.2.2(c)1. representative upon final acceptance of the system. (d) Detailed troubleshooting instructions for each trouble (a)• An owner's manual and installation instructions cover- condition generated from the monitored field wiring, including ing all system equipment; and opens, grounds, and loop failures. These instructions should include a list of all trouble signals annunciated by the system, (b) Record drawings. a description of the condition(s) that causes such trouble sig- . nals, and step -by -step instructions describing how to isolate A- 1- 7.2.2(a) The owner's manual should include: such problems and correct them (or how to call for service, as appropriate). (a) A detailed narrative description of the system inputs, (e) A service directory, including a list of names and tele- evacuation signaling, ancillary functions, annunciation, in- phone numbers of those who provide service for the system. tended sequence of operations, expansion capability, applica- tion considerations, and limitations. 1 -7.2.3 Central Station Fire Alarm Systems. It shall be (b) Operator instructions for basic system operations, conspicuously indicated by the prime contractor (see Chapter including alarm acknowledgment, system reset. interprets 4) that the fire alarm system providing service at a protected Lion of system output (LEDs, CRT display, and printout), oper- ation of manual evacuation signaling and ancillary function premises complies with all applicable requirements of this controls, and change of printer paper. code by providing a means of verification as specified in (c) A detailed description of routine maintenance and test- either 1- 7.2.3.1 or 1- 7.2.3.2. ing as required and recommended and as would be provided under a maintenance contract, including testing and mainte- 1-7.2.3.1 The installation shall be certificated - nance instructions for each type of device installed. This infor- mation should include the following: 1- 7.2.3.1.1 Central station fire alarm systems providing 1. A listing of the individual system components that re- service that complies with all requirements of this code shall quire periodic testing and maintenance: be certificated by the organization that has listed the prime NATIONAL FIRE ALARM CODE HANDBOOK