Correspondence (2) 4it 2.6
City of Tigard, Oregon o 13125 SW Hall Blvd. o Tigard, OR 97223 U �� � `� `
V�.
November 8, 2010 ( , ; `
' r �� En y t y
RE: FIRE REPAIR
Project Information ' " `:
Building Permit: BUP2010 -00241 Construction Type: 5B
Address: 11046 SW Greenburg Rd. Occupancy Type: R -2
A Area: 18,306 Sq. Ft. Stories: 2
Name: Ash Creek Condos Sprinkled: Required
The plan review was performed under the State of Oregon Structural Specialty Code
(OSSC) 2010 edition and the 2010 Oregon State Fire Code
1) All improvements made to the building shall be inspected prior to covering.
2) Make approved set of plans available for all inspections.
3) All framing shall conform to accepted engineering standards.
FIRE LIFE AND SAFETY I GENERAL
• A fire alarm system shall be installed as per OSSC 907.2.9.
o Smoke detectors shall be installed as per OSSC 907.2.11.2.
• This building shall be fully sprinkled with a NFPA 13R system.
0 Recommended by Fire Marshall to install fire hydrants within 400 ft of non
sprinkled buildings and 600 ft of sprinkled buildings.
• The means of egress shall be provided with illumination of not less than 1 foot
candle at the floor level anytime the building is occupied. The means of egress
illumination shall be provided with a second source of power in case of primary
power loss.
Amended Construction Documents: Work shall be installed in accordance with the
approved construction documents, and any changes made during construction that are
not in compliance with the approved construction documents shall be resubmitted for
approval pp as an amended set of construction documents. OSSC 106.4
Work Commencing Before Permit Issuance: Any person who commences any work
on a building or structure before obtaining the necessary permits shall be subject to an
investigation fee equal to the permit fee that shall be in addition to the required permit
fees. OSSC 108.4
Inspections: Construction or work for which a permit is required shall be subject to
inspection by the building official and such construction or work shall remain accessible
and exposed for inspection purposes until approved. Approval as a result of an
inspection shall not be construed to be an approval of a violation of the provisions of this
code or of other laws or ordinances of the jurisdiction. Inspections presuming to give
Phone: 503.639.4171 o Fax: 503.684.7297 o www.tigard or.gov o TTY Relay: 503.684.2772
authority to violate or cancel the provisions of this code or of other laws or ordinances of
the jurisdiction shall not be valid. OSSC 109.1
Approval Required: Work shall not be done beyond the point indicated in each
successive inspection without first obtaining the approval of the building official. The
building official, upon notification, shall make the requested inspections and shall either
indicate the portion of the construction that is satisfactory as completed, or notify the
permit holder or his or her agent wherein the same fails to comply with this code. Any
portions that do not comply shall be corrected and such portion shall not be covered or
concealed until authorized by the building official. OSSC 109.6
Use and Occupancy: No building or structure shall be used or occupied, and no
change in the existing character, use or occupancy classification of a building or
structure or portion thereof shall be made until the building official has issued a
certificate of occupancy for such change in character, use or occupancy, therefore, as
provided herein. Issuance of a certificate of occupancy shall not be construed as an
approval of a violation of the provisions of this code or of other ordinances of the
jurisdiction. OSSC 110.1
Respectfully,
Dan Nelson
Senior Plans Examiner
(503) 718 -2436
dann @tigard - or.gov