Loading...
Plans OUTDOOR ( CONDENSOR ( �4 UNIT m i, .° ,. fl p ell i i \ SEISMIC ���� � � CABLE ANCHORS 4 � z w OD, - o 1-4 a A s/ 8 r� EYE k% •l 3 /8'0x6 LAGS Q z TYP (4) U P.T. 4x4 am.. I� Aar Q; z Alm OU -1 1 .5 -TON F z ■ d MITSUBISHI W ' • -Al 8-N-HA3 E-+ c z ON ROOF - SEISMIC ANCHOR DETAIL Q d SCALE: N.T.S. � m (2 X - RAY LINESET LAB 41U, ABOVE CEILING a 101 ) TO OUTDOOR UNIT CITY OF TIGARD ON ROOF APprovedAWK.44.r [ u/ i Conditionally Approved [ J .. 2 See Letter to: Follow [ I a 1 1 t I Attached [ Perm it Number: INA(G to - i?cJ . I U-1 1 .5 -TON Ad :lZ - -�` .41 0 z MITSUBISHI By: Date: r •-4 I a PKA -Al 8HA ABOVE DOOR OFFICE COPY E a 1 HVAC FLOOR PLAN 1/4 =1 -0 w g ° � z col NORTH DUCTLESS -SPLIT EQUIPMENT SCHEDULE: c 0 o x TAG MFG. MODEL # VOLTAGE COOLING HEATING CFM WEIGHT REMARKS 2 E F 1 U M 8 a. IU MISTUBISHI PKA -A181 MBTU - A / 1.5T 208/230 1 18 MB - 320 -425 29 LBS w 1Amp 1 1 OU -1 MISTUBISHI FUY- A18NHA3 / 1.5T 2081230 1Ph. 18 MBTU - -- 97 LBS .;a C AND ME „ 13 Amp . o. . RfFACCM. IX ANY TO .,:;gig, NOTES: P„s,� ,,. -- .-- 1 PM NENTLY LABELED FOR AREA SERVED. ca 35. X67 EF t M 1.0 I oF I \G \: \ v im , \•"• , 16, j ogy,,_ litilisos, ii.. I i ,,, ' "' ' , ' ,,„,r4s 4 ' I t., N ill ' G rl '' ';:41 . ' 11 . rf' ,i .17 1 41 IT": 11'11.1c 1 ' -'):— '''.. '' 1 ; . P • � r r r I „,, .. . ' „, , , L R ;, } I r C? ' YC f f , , , Illik l'i, ,fi jj ,p, .,„11144441r---. �,c¢�, -- r (i It p�[.� ,r q . Y t' i ;�'i ! 1' 4 • s :I:L.:i I' ' '' 1 r �` ry ' �° t q . . . ' I , 1 } .% ,I ,�y� ,,, I 1 1 p� f . ' . � ` s r � s I.PrEI „� � I ., , I I!% g s s ` r k 4 t ∎ ' 0 1 P 4'11 Il y 1 o r ` *1w ' t 7• ''' , 3 , M h 1 f i it { ” % NIL I s ,, ,r.n` � \14 >h r ,. r h % —.. \ \ 01 „ . T , ,.. . s... _,,, , , 0 t MITSUBISHI MIK ELECTRIC MI If. SLIIM,. HVAC Advanced Products Division Split-ductless A/C and Heat Pumps SUBMITTAL DATA: PKA -A18HA & PUY- A18NHA3 18,000 BTU /H WALL - MOUNTED AIR•CONDEHONINGSYSTEM Job Name Location: Date: Purchaser Engineer: Submitted to: For ❑ Reference ❑ Approval ❑Construction Unit Designation: Schedule No.: GENERAL FEATURES • Wall- mounted indoor unit for residential and commercial .--.. ' ul , , a applications �3 • s +l � %; � i ,s t A111 ' a r4, - , • Shiny - white – exterior plastic; compact design Indoor Unit : PKA - A18HA , 5 , t , • Quiet operation—both indoor and outdoor units 4 , ! • PAR -21 MAA wired remote controller is included k,t � M 4 , ..; , • Self -check function— integrated diagnostics , '` . • Limited warranty: five years on parts and defects and seven years , ' i t " t – on compressors Remote Controller: PAR -21MAA Outdoor Unit PUY- A18NHA3 OPTIONAL ACCESSORIES Indoor Unit Indoor Unit MCA 1 A • Remote Temperature Sensor (PAC- SE41TS -E) Fan Motor 0.33 F.L.A. Outdoor Unit Fan Motor Output 30 W • M -NET Adapter (PAC -SF81 MA E Airflow (Lo - Mid - Hi) 320 - 370 - 425 Dry CFM 290 - 335 - 380 Wet CFM • Air Outlet Guide (PAC- SG58SG -E) • Wind Baffle (WB -PA1) Air Filter Polypropylene Honeycomb Sound Pressure Level (Lo - Mid - H) 36 - 40 - 43 dB(A) DIMENSIONS UNIT INCHES f MM W 35 -3/8 / 898 D 9 -13/16 / 249 H 11 -5/8 / 295 Cooling* Weight 29 lbs. / 13 kg Rated Capacity 18,000 Btu /h External Finish Munsell No. 1.0Y 9.2 / 0.2 Minimum Capacity 8,000 Btu /h Field Drainpipe Size O.D. 5/8" / 16 mm SEER 15.3 Btu /h/W Wall- mounted Remote Controller. PAR -21 MAA Total Input 2 240 W (See Data Submittal Sheet) ' Rating Conditions (Cooling) - Indoor: 80°F (27 °C) DB / 67 °F (19 °C) WB. Outdoor: 95 °F (35 °C) DB / 75 °F (24 °C) WB. Outdoor Unit Compressor DC Inverter - driven Twin Rotary Electrical Requirements MCA 13 A Power Supply 208 / 230V, 1- Phase, 60 Hz Fan Motor 0.35 F.L.A. Breaker Size 15 A Sound Pressure Level Voltage Cooling ...46 dB(A) Indoor - Outdoor S1 -S2 AC 208 / 230V Indoor - Outdoor S2 -S3 DC 24V DIMENSIONS INCHES / MM Indoor - Remote Controller DC 12V W 31 - 1/2 / 800 D 13 +7/8/330 +23 OPERATING RANGE H 23 -5 /8 / 600 Indoor Intake Air Temp. Outdoor Intake Air Temp. Weight 97 lbs. /44 kg Cooling Maximum 95°F (35°C) DB, 71°F (22°C) WS 115 °F (46 °C) DB External Finish Munsell No. 3Y 7.8 / 1.1 Minimum _67°F (19°C) DB, 57°F (14°C) WB 0 °F" ( -18 °C) DB Refrigerant Type R410A " \Mth optional wind baffle accessory installed. If not installed, the minimum Refrigerant Pipe Size O.D. temperature will be 23 °F ( -5 °C) DB. Gas Side 1/2" / 12.7 mm Liquid Side 1/4" / 6.35 mm Max. Refrigerant Pipe Length 100' / 30 m Max. Refrigerant Pipe Height Difference 100' / 30 m Connection Method Flared OP R - I R DIMENSIONS: PKA -A18HA 15- 51161387 7.1!2.192 Top side Unit: inch (mm) III IiEM I�I =NI I II _ -Ill Itu11 =III ∎ ∎; =MS 1 • -� ••••••• 6. . 1117=NA. = lam∎ Moo96oard 23-9/35(599) Front side Right Side I' 1 'j \ \,, We - 9.13!16(249) .I 3/16(5) D j� I /B Z7. 1716(6861 91/18(155) Knockout hole (55) /a 4•6 Aping 35- 3/8(898) Knock ad nob From side/GliMe open) for eV gprg Sleeve Through hole (purchased localy) $2.12 -33-3/8 02 -112-0-116 I% 11 =- - O - � I t'k5_O'B) 065 -080) !i i i i i II I WEE l ;I T Z ermi'e Ndcx mr . dom7wmocr mnnedin I�ne _ - _ -- I 1 I I � hewn(bed to peer ',ply ixum; • ) - m - --- - 1 i Terminal dock for -- % m l 14A-remote weedier _ e r a�I l \I (( PKA.A HA models) ) 0 17- 15/16(457)Ga. p.pe 6.58(169) , 6mergenetoparelion swncn 411 man 9T. nip) VanNaulo under ado O€FROST/STANO BY lama •., anon len • 24- 1/16(612) 3 1 1 Refrigerant Liquid pipe 114F (¢6.35) I r - I Piping __ _ �� Gas PiPe 1/2F (12.7) *lo en pe .1 la -.. � Drain hose 05111 (016) 0.0 *lower (epee - - nde `\ -.___I 1.• manual) , Knadr out hob Renewer C for lower piping B Center measurement hole ¢302(92.5) 4- 05l160) a Bolt hole = Mount board _ o A. a • F-, Rg « « c r3-. § £ ^ odr unit outline 7743/1645.1) r, .... = - _ aa a ' Ind � ^ F sappng L T a N N n `a a s 6 ,. al hole i3' ry 4 . 6n 303 E. - �S d � r3- Y3- 0 �NIZO Ilr 15136(2 1 1.6) ,1���� ��- �i,.���_r�� Illls 5/8116 == •`: a -� ..aw. 4 ' �� 31120 7- 1/16(26 " -� �_ •� - ^a 1 1 1- 9/16111 u � 3-r_ Z . �� � 1 -114(]Z.7 3- 3- /1 617 8 I�i. - `' ^` 2.111(66(153.0 3- 9116(91) ■� te a t - s " � 2.9/18(fi8) 3.5) = : - - e• 4- 1/16(10 ∎ ■� 1-9/16(1181 51126 61/!366. � aLil� ;1 �� 611575) 7(+76 � .0 �7ma a�r0 QS reel 8(203 5) 9.178(2325) No �I♦_ir .� /I I, 911161231.51 9- 15/16(253.5) ∎ M' . - War MI. �■III1 ��111 III 10.51127]21 eh rear B d . R Anatole hole for ''$ u$ n a ppin6 ^ s � pipa9 c = 3 _ a wlrweb .. g ' 5.1 r t 2 31 4•12.9116170.319) as a _ lnr p'ping 6,00403 hale for prong -1116 Required spece(Indoor unit) )mm) M .det a 9� r it 13111' v� 7/16(12.5)'2. 3116(76) c a _ ° % � 1 - - �,tl m e.a P C. a " - 1. 11/16(47) aa_ 0 d I 1 hen 1.33/32(50) Mater T I I �I� l i1 S (Cg 1229116 .5- 7/6(750) / 1-01/16(13) ■ 3 8 DIMENSIONS: PUY A18NHA3 A 400 <15- 25/32> N el M 347.5 <13 -11/16 • <1 -5/16> drain hole Unit: mm (inch) N V Air intake / N `° IVL N 4II/ �n n ' eV ridirM M M i (0A 0 Air intake b v .. rn o rp o M o t1' 45.4 0- 25132> I Y A N el Air discharge °' 4'• 40 <1 -9/16> in N 18<23/32> _ 23 <29/32> Service panel _ 22 <7/8> Service panel for charge plug — 2-22.2<7/8> immorm■En 1/2 conduit hole C for li uid i e A q P P N FLARE #6.35 <1 /4> A IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII N N Eli N I A I IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII �1 A V to 7 co IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII 0 o IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII :a � l J r' "' 4, N r .!_ � \ Connection for gas pipe 144 <5- 21/32> FLARE 012.7<1/2> 150 <5- 29/32> Service port 183 <7 -7/32> 287.501-11/32> Installation bolt pitch 500 <19- 11/16> 69 <2- 23/32> 1 800 <31 -1/2> FOUNDATION BOLTS Clearance space around the outdoor unit Min.t00mm <3- 15/76> as long as Please secure the unit firmly .,,.."\. no obstacle is placed on the with 4 foundation M10 <W3 /8> bolts. Nm (Bolts, washers and nut must , o rear and light- and -left sides be purchased locally) J of the unit yFoundation bolt height> NMI 'C> (/) 111 rii Min.100mm<3- 15/16> Min.350mm <13- 25/32> M I�� FOUNDATION/ el /////// N V E .1 I� x 6 II 1 g Min.500mm<19-11/16> Min.100mm <3- 15/16> PIPING WIRING DIRECTION Piping and wiring connection can 2 sides should be open in the right, left and rear side. be made from the mar direction only. Minimum installation space for outdoor unit '1 In the place where short cycle tends to occur, cooling and heating capacity and power consumption might get lowered 10%. Air outlet guide (optional) will help them improve. '2 If air discharges to the wall, the surface might get stained. ; ,x: MITSUBISHI L c,, :..„ s; ; � r; NIL ELECTRIC i CERTIFIED. PARTNER HVAC Advanced Products Division xa ro.anddusctary.crq - 3400 Lawrenceville Suwanee Rd thntary Sr a1 AC Suwanee. GA 30024 Aafl! Standad 2%440 Tele: 678.376 -2900 • Fax: 800 - 889 -9904 < /STEO ® Toll Free: 800 -433 -4822 ( #3) www.mehvac.com C SD - PKA -A18HA / PUY- A18NHA3 - 200907 ® MITSUBISHI ELECTRIC / HVAC 2009 Specifications are subject to change without notice.