Loading...
Plans[Page Too Large for OCR Processing] [Page Too Large for OCR Processing] / 1 4E C-2oIZ - co2I 2.- CO Mcheck Software Version 3.9.0 Mecha Comp Certificate Oregon Energy Efficiency Specialty Code Section 1: Project Information Project Type: New Construction Project Title : Burgerville Construction Site: Owner /Agent: Designer /Contractor: 12785 SW Pacific Hwy Clifford Hood Tigard, OR 97223 Hood- McNees, Inc. 1923 SE Stark St. Portland, OR 97214 Section 2: General Information Building Location (for weather data): Tigard, Oregon Climate Zone: 4c Section 3: Mechanical Systems List Quantity System Type & Description 1 RTU -1 (Single Zone) : Heating: 1 each - Central Furnace, Gas, Capacity = 115 kBtu /h, Efficiency = 81.00% Et Cooling: 1 each - Rooftop Package Unit, Capacity = 70 kBtu /h, Efficiency = 11.00 EER, Air - Cooled Condenser, Air Economizer 1 RTu -2 (Single Zone) : Heating: 1 each - Central Furnace, Gas, Capacity = 72 kBtu /h, Efficiency = 82.00% Et Cooling: 1 each - Rooftop Package Unit, Capacity = 59 kBtu/h, Efficiency = 13.00 SEER, Air - Cooled Condenser, Air Economizer 1 Water Heater 1: Gas Storage Water Heater, Capacity: 75 gallons, Input Rating: 80 Btu /h, Efficiency: 0.52 % Et Section 4: Requirements Checklist In the following requirements, the relevant code section reference is shown in H. ' +' denotes that more details exist in the specified code section. Checkboxes identify requirements that the applicant has not acknowledged as being met. Check marked requirements identify those the applicant acknowledges are met or excepted from compliance. 'Plans reference page /section' identifies where in the plans/specs the requirement can be verified as being satisfied. Requirements Specific To: RTU -1 : v 1. [503.2.3 +] Equipment meets minimum efficiency: Central Furnace (Gas): 80.00 % Et (or 78% AFUE) 4 / 2. [503.2.3 +] Equipment meets minimum efficiency: Rooftop Package Unit: 11.00 EER (11.2 IEER) I / 3, [503.2.6 +] Energy recovery ventilation systems. Individual fan systems that have both a design supply air capacity of 5,000 cfm or greater and a minimum outside air supply of 70 percent or greater of the design supply air quantity have an energy recovery system. Plans reference page /section: N/A 4. [503.3.1 +] Supply air economizers shall be provided on each cooling system and are capable of providing 100 - percent outdoor air, even if additional mechanical cooling is required to meet the cooling load of the building. Systems provide a means to relieve excess outdoor air during economizer operation to prevent overpressurizing the building. Plans reference page /section: Ml.1 Requirements Specific To: RTu -2 : v 1. [503.2.3 +] Equipment meets minimum efficiency: Central Furnace (Gas): 80.00 % Et (or 78% AFUE) v 2. [503.2.3 +] Equipment meets minimum efficiency: Rooftop Package Unit: 13.00 SEER Project Title: Burgerville Report date: 03/01/12 Data filename: J:\proj \1849 Burgerville Tigard\Burgerville Tigard.cck Page 1 of 4 I ✓ 3. [503.2.6 +] Energy recovery ventilation systems. Individual fan systems that have both a design supply air capacity of 5,000 cfm or greater and a minimum outside air supply of 70 percent or greater of the design supply air quantity have an energy recovery system. Plans reference page /section: N/A 6 / 4. [503.3.1 +] Supply air economizers shall be provided on each cooling system and are capable of providing 100 - percent outdoor air, even if additional mechanical cooling is required to meet the cooling load of the building. Systems provide a means to relieve excess outdoor air during economizer operation to prevent overpressurizing the building. Plans reference page /section: M1.1 Requirements Specific To: Water Heater 1 : ✓ 1. [504.2 +] Newly purchased equipment meets the efficiency requirements. Gas Storage Water Heater efficiency: 80.00 % Et (112 SL, kBtu /h) 6 / 2. [504.2] Service water - heating equipment performance efficiency. Water heating equipment efficiency has been verified through data furnished by the manufacturer or through certification under an approved certification program. 6 / 3. [504.3] Temperature controls. Service water- heating equipment have controls to allow a setpoint of 110 °F for equipment serving dwelling units and 90 °F for equipment serving other occupancies. The outlet temperature of lavatories in public facility rest rooms is limited to 110 °F. Plans reference page /section: `/ 4. [504.4] Heat traps. Water- heating equipment not supplied with integral heat traps and serving noncirculating systems have heat traps on the supply and discharge piping associated with the equipment. Plans reference page /section: P1.1 6 / 5. [504.5 +] Pipe Insulation. For automatic - circulating hot water and externally heated (such as heat trace or impedance heating) systems, piping is insulated in accordance with the specifications of this section. 6 / 6. [504.6 +J Hot Water System Controls. Systems designed to maintain usage temperatures in hot water pipes is turned off automatically when the hot water system is not in operation and has demand sensing controls that turn off the system when there is no demand when the system is operational. A check valve or similar device is installed per requirement details. Plans reference page /section: P1.1 Generic Requirements: Must be met by all systems to which the requirement is applicable: `/ 1. [503.2.1 +] Calculation of heating and cooling loads. Design loads are determined in accordance with the procedures described in the ASH RAE /ACCA Standard 183. Alternatively, design loads have been determined by an approved equivalent computation procedure. ✓ 2. [503.2.1.1 +] Packaged Electric Equipment. Specified packaged electrical equipment has a heat pump as the primary heating source. Requirement is not applicable. Plans reference page /section: ✓ 3. [503.2.2 +] Equipment and system sizing. Heating and cooling equipment and systems capacity do not exceed the loads calculated in accordance with Section 503.2.1. Plans reference page /section: 6 / 4. [503.2.3 +] HVAC Equipment Performance Requirements. Reported efficiencies have been tested and rated in accordance with the applicable test procedure. The efficiency has been verified through certification under an approved certification program or, if no certification program exists, the equipment efficiency ratings are supported by data furnished by the manufacturer. 6 / 5. [503.2.4.1 +] Thermostatic Controls. The supply of heating and cooling energy to each zone is controlled by individual thermostatic controls that respond to temperature within the zone. Plans reference page /section: M2.1 ✓ 6. [503.2.4.1.1] Heat pump supplementary heat. Heat pumps having supplementary electric resistance heat have controls that, except during defrost, prevent supplementary heat operation when the heat pump can meet the heating load. Plans reference page /section: N/A 6 / 7. [503.2.4.2] Set point overlap restriction. Where used to control both heating and cooling, zone thermostatic controls provide a temperature range or deadband of at least 5 °F (2.8 °C) within which the supply of heating and cooling energy to the zone is capable of being shut off or reduced to a minimum. Plans reference page /section: M1.1 6 / 8. [503.2.4.3] Optimum Start Controls. Each HVAC system has controls that vary the start-up time of the system to just meet the temperature set point at time of occupancy. Plans reference page /section: MI./ ✓ 9. [503.2.4.4 +] Off -hour controls. Each zone is provided with thermostatic setback controls that are controlled by either an automatic time clock or programmable control system. Project Title: Burgerville Report date: 03/01/12 Data filename: J:lproj11849 Burgerville Tigard\Burgerville Tigard.cck Page 2 of 4 • Plans reference page /section: M1.1 `/ 10. [503.2.4.5 +] Shutoff damper controls. Both outdoor air supply and exhaust are equipped with not less than Class I motorized dampers. Plans reference page /section: M1.1 v 11. [503.2.4.6 +] Freeze Protection and Snow melt system controls. Freeze protection systems, such as heat tracing of outdoor piping and heat exchangers, including self - regulating heat tracing, include automatic controls capable of shutting off the systems when outdoor air temperatures meet code criteria. Plans reference page /section: N/A ✓ 12. [503.2.4.8] Separate air distribution systems. Zones with special process temperature requirements and /or humidity requirements are served by separate air distribution systems from those serving zones requiring only comfort conditions; or shall include supplementary control provisions so that the primary systems may be specifically controlled for comfort purposes only. Plans reference page /section: M2.1 6 / 13. [503.2.4.9] Humidity control. If a system is equipped with a means to add or remove moisture to maintain specific humidity levels in a zone or zones, a humidity control device is provided. Plans reference page /section: N/A 6 / 14. [503.2.4.9.1] Humidity control. Where a humidity control device exists it is set to prevent the use of fossil fuel or electricity to produce relative humidity in excess of 30 percent. Where a humidity control device is used for dehumidification, it is set to prevent the use of fossil fuel or electricity to reduce relative humidity below 60 percent. Plans reference page /section: N/A `/ 15. [503.2.4.9.2] Humidity control. Where a humidity control device exists it is set to maintain a deadband of at least 10% relative humidity where no active humidification or dehumidification takes place. Plans reference page /section: N/A ✓ 16. [503.2.5] Ventilation. Ventilation, either natural or mechanical, is provided in accordance with Chapter 4 of the International Mechanical Code. Where mechanical ventilation is provided, the system has the capability to reduce the outdoor air supply to the minimum required by Chapter 4 of the International Mechanical Code. Plans reference page /section: M1.1 ✓ 17. [503.2.5.1 +] Demand controlled ventilation (DCV). DCV is required for spaces larger than 500 ft2 for simple systems and spaces larger than 150 ft2 for multiple zone systems. Plans reference page /section: M1.1 6 / 18. [503.2.5.2 +] Kitchen hoods. Kitchen makeup is provided as required by the Oregon Mechanical Specialty Code. Plans reference page /section: Work by Others 6 / 19. [503.2.5.3 +] Enclosed parking garage ventilation controls. In Group S -2, enclosed parking garages used for storing or handling automobiles employs automatic carbon monoxide sensing devices. Plans reference page /section: N/A 6 / 20. [503.2.7 +] Duct and plenum insulation and sealing. All supply and return air ducts and plenums are insulated with the specified insulation. When located within a building envelope assembly, the duct or plenum is separated from the building exterior or unconditioned or exempt spaces by a minimum of R -8 insulation. All ducts, air handlers and filter boxes are sealed. Joints and seams comply with Section 603.9 of the International Mechanical Code. 6 / 21. [503.2.7.1.1 +] Low - pressure duct systems. All longitudinal and transverse joints, seams and connections of low- pressure supply and return ducts are securely fastened and sealed with welds, gaskets, mastics (adhesives), mastic -plus- embedded - fabric systems or tapes installed in accordance with the manufacturer's installation instructions. Plans reference page /section: M1.1 6 / 22. [503.2.7.1.2 +] Medium - pressure duct systems. All ducts and plenums designed to operate medium - pressure are insulated and sealed in accordance with Section 503.2.7. Pressure classifications specific to the duct system are clearly indicated on the construction documents. Plans reference page /section: N/A 23. [503.2.7.1.3 +] High - pressure duct systems. Ducts designed to operate at high - pressure are insulated and sealed in accordance with Section 503.2.7. In addition, ducts and plenums are leak- tested in accordance with the SMACNA HVAC Air Duct Leakage Test Manual. Plans reference page /section: N/A 6 / 24. [503.2.9.1 +] Air system balancing. Each supply air outlet and zone terminal device is equipped with means for air balancing in accordance with the requirements of IMC 603.17. Discharge dampers intended to modulate airflow are prohibited on constant volume fans and variable volume fans with motors 10 horsepower. Project Title: Burgerville Report date: 03/01/12 Data filename: J: \proj \1849 Burgerville Tigard \Burgerville Tigard.cck Page 3 of 4 Plans reference page /section: M11 .1 v 25. [503.2.9.3 +] Manuals. The construction documents require that an operating and maintenance manual be provided to the building owner by the mechanical contractor. See long description for specifications. Plans reference page /section: M1.1 v 26. [503.2.10 +] Air System Design and Control. Each HVAC system having a total fan system motor nameplate hp exceeding 5 hp meets the provisions of Sections 503.2.10.1 through 503.2.10.2. Plans reference page /section: N/A v 27. [503.2.10.1 +] Allowable fan floor horsepower. Each HVAC system at fan system design conditions does not exceed the allowable fan system motor nameplate hp (Option 1) or fan system bhp (Option 2) as shown and calulated in requirement details. f Exception applies: Individual exhaust fans with motor nameplate horsepower of 1 hp or less. Plans reference page /section: ✓ 28. [503.2.10.2 +] Motor nameplate horsepower. For each fan, the selected fan motor is no larger than the first available motor size greater than the brake horsepower (bhp). Plans reference page /section: v 29. [503.2.10.3.1] Large Volume Fan Systems. Fan systems over 8,000 (7 m3 /s) cfm without direct expansion cooling coils that serve single zones reduce airflow based on space thermostat heating and cooling demand. A two -speed motor or variable frequency drive reduces airflow to a maximum 60 percent of peak airflow or minimum ventilation air requirement as required by Chapter 4 of the International Mechanical Code, whichever is greater. Plans reference page /section: N/A ✓ 30. [503.2.10.3.2 +] All air - conditioning equipment and air - handling units with direct expansion cooling and a cooling capacity at ARI conditions greater than or equal to 110,000 Btu /h that serve single zones have their supply fan operation controlled according to code specific requirements. Plans reference page /section: N/A `/ 31. [503.2.10.4] Series fan - powered terminal unit fan motors. Fan motors for series fan - powered terminal units are electronically- commutated motors and have a minimum motor efficiency of 70 percent when rated in accordance with NEMA Standard MG 1 -2006 at full load rating conditions. Plans reference page /section: N/A ✓ 32. [503.2.12] Hot Gas Bypass Limitation. For cooling systems <= 240 kBtu /h, maximum hot gas bypass capacity is no more than 50% total cooling capacity. Plans reference page /section: N/A v 33. All service water heating requirements are listed in requirements section specific to the system. Section 5: Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications and other calcu submitted with this permit application. The proposed mechanical systems have been designed to meet the Oregon Energy Effici-n; Specialty Code requirements in COMcheck Version 3.9.0 and to comply with the mandatory requirements in the Resuireme -cklist. �+����► � +- '�.._ ��. � r�11� 414-z ame - itl- Signature Dat Section 6: Post Construction Compliance Statement D HVAC record drawings of the actual installation, system capacities, calibration information, and performance data for each equipment provided to the owner. • HVAC O &M documents for all mechanical equipment and system provided to the owner by the mechanical contractor. ❑ Written HVAC balancing and operations report provided to the owner. The above post construction requirements have been completed. Principal Mechanical Designer -Name Signature Date Project Title: Burgerville Report date: 03/01/12 Data filename: J: \proj11849 Burgerville Tigard\Burgerville Tigard.cck Page 4 of 4 /UtEC2C 12 - 04 2 2_ 12-7 $ 5 sw Pc,c`4 Hw GAS PIPING INSTALLATIONS U V % % ,3 c,■t 6 01 Gas Natural TABLE 402.4(3) Inlet Pressure 2.0 psi SCHEDULE 40 METALLIC PIPE Pressure Drop 1.0 psi Specific Gravity 0.60 PPE SIZE (inch) Nominal i4 3 /4 1 l l' /, 2 24 3 4 Actual ID 0.622 0.824 1.049 1.380 1.610 2.067 2.469 3.068 4.026 Length (ft) Capacity In Cubic Feet of Gas Per Hour 10 1,510 3,040 5.560 11.400 17,100 32,900 52,500 92,800 189.000 20 1.070 2350 3,930 8,070 12.100 23,300 37,100 65.600 134.000 30 869 1,760 3,210 6.590 9.880 19,000 30,300 53,600 109,000 40 753 1,520 2380 5.710 8350 16,500 26,300 46,400 94.700 50 673 1,360 2,490 5,110 7.650 14,700 23,500 41.500 84.700 60 615 1,240 2,270 4.660 6.980 I3,500 21.400 37.900 77.300 70 569 1,150 2,100 4320 6.470 12,500 19,900 35.100 71,600 80 532 1,080 1,970 4,040 6,050 11,700 18,600 32.800 67.000 90 502 1,010 1,850 3,810 5,700 11,000 17,500 30.900 63.100 100 462 934 1,710 3,510 5.260 10,100 16,100 28.500 58.200 r250 125 414 836 1,530 3,140 4.700 9,060 14,400 25,500 52.100 150 372 751 1,370 2,820 4.220 8,130 13,000 22.900 46.700 175 344 695 1,270 2,601 3.910 7,530 12,000 21.200 43.300 200 318 642 1,170 2,410 3.610 6,960 11,100 19.600 40.000 1 279 583 1,040 2.140 3.210 6,180 9,850 17.400 35300 300 253 528 945 1,940 2.910 5.600 8,920 15100 32.200 350 232 486 869 1,790 2.670 5.150 8,210 14,500 29.600 r l e ec let,4-(A- \ oY)a t" rw4) ry • M no M6ti 4., 115 rlta0 72 016 Axtiued v)d, toll M I � � 41Na• 'x 80 A. Mme- • �= 4 u(ld�� si 2 r • . 1-'CAA t, • Y 16, °' Cr u 2 I kctk '/4" A. 41[C )._G 12— CO - 2_12._ Phone: 503-234-5071 JOHNSON 2220 SE Ninth Ave., Portland, OR 97214 AIR PROIDUCTS Fax: 503 - 233 -0451 800- 848 -5199 SUBMITTAL PROJECT: Burgerville T.I. LOCATION: Tigard, Oregon ARCHITECT: ENGINEER: Hood - McNees Inc. CONTRACTOR: Plumbing & Mechanical Contractors DATE SUBMITTED: April 11, 2012 PROJECT MANAGER: Ron Enkelis EMAIL: renkelis • .ohnsonair.com ACCOUNT MANAGER: EMAIL: PLAN DATE: March 1, 2012 ADDENDUMS: None WE ARE PLEASED TO SUBMIT THE FOLLOWING LIST OF EQUIPMENT FOR APPROVAL. BASED UPON INFORMATION RECEIVED WE BELIEVE THIS MATERIAL CONFORMS TO THE SPECIFICATIONS. IT SHALL REMAIN THE CONTRACTOR'S RESPONSIBILITY TO VERIFY SIZES AND QUANTITIES PRIOR TO ORDER RELEASE. MATERIAL WILL BE RELEASED TO PRODUCTION UPON RETURN OF APPROVED SUBMITTALS TO JOHNSON AIR PRODUCTS AT 2220 S.E. 9TH AVE.. PORTLAND, OREGON 97214. MATERIAL SUBMITTED: Air Distribution SPECIFICATIONS: MANUFACTURER: Price Ind.A1 (Please see attached literature) p rico Price All -In -One Detailed Submittal Schedule Grilles /Registers /Diffusers Sorted By Item Tag Job Name: Burgerville TI Pacific Hwy Date: 04/11/2012 Job Number: QP00000234 Contractor: Entered By: Ron Enkelis Engineer: Reps Job No: SDA No.: Location: Tigard, OR Item Tag Model Line No Qty Size Border Pattern Panel Size Accessories Finish Submittal Length Width Neck LxW 12 3 SMD 1 2 6 6 3P 4A 24 24 SR3 6 B12 218791,222044 SMD 2 1 12 12 3P 2S 24 24 SR3 10 B12 218791,222044 SMD 3 3 15 15 3P 1S 24 24 SR3 12 B12 218791,222044 SMD 4 2 6 6 6 4A SR3 6 B12 218791,222044 RCD 5 3 10 7 B12 210473,223934 SMD 9 3 12 12 3P 4A 24 24 SR3 10 B12 218791,222044 SMD 10 1 15 15 3P 2S 24 24 SR3 12 B12 218791,222044 SMD 11 5 15 15 3P 4A 24 24 SR3 12 B12 218791,222044 CR 80DAL 7 2 22.000 22.000 F LI 0 B12 222015 CR 80DAL 8 1 30.000 18.000 F SW A B12 222015 HS 520D 6 4 14.000 4.000 F L A SW B12 219693 Accessories SR3= square to round adapter 7= round damper 0= no screw holes A= with screw holes The order and sale are made pursuant to the terms of the Sales Agreement and the Sales Policies set out in the latest Customer Service Handbook. See Section AA in price lists. Page 1 of 1 prices Submittal Sheet SMD /AMD MODULAR DIFFUSER OPTIONS: 1=0-------D - LISTED DUCT SIZE -- ❑ 3 CDATT D ST1 Ft QPPosrn 131 ADF DAUPfR (SI IIPPrD 100SF) NECK OVERALL - D +Po "(3) ❑ 3L COATED STEEL OPPOSED BLADE DAMPER IF* (FACE OPERABLE, SHIPPED LOOSE) fl 3AL ALUM OPPOSED BLADE DAMPER (SHIPPED LOOSE) °'i. (14) 0 3LAL ALUM OPPOSED BLADE DAMPER (FACE OPERABLE, SHIPPED LOOSE) fi + ❑ SR SQUARE TO ROUND ADAPTOR (SHIPPED MOUNTED) /1/2" (S ❑ SR2 SQUARE TO ROUND ADAPTOR (SHIPPED LOOSE) ........e.)=2 X SF3 SQUARE 10 HOUND ADAP IUR (SHIPPED LOOSE) WITH STEEL OPPOSED BLADE DAMPER (SHIPPED LOOSE) I+-1 +/2 (38) TYPICAL SPACING ❑ SR3L SQUARE TO ROUND ADAPTOR (SHIPPED LOOSE) �� WITH FACE OPERABLE STEEL DAMPER (SHIPPED LOOSE) SMD - STEEL CONSTRUCTION 0 SR3AL SQUARE TO ROUND ADAPTOR (SHIPPED LOOSE) (EXTR. ALUM. FRAME - STYLE 33 T -BAR AND STYLE 17 FINEUNE) WITH AI UM DPPO,FO E31ADF DAMPER (,131P1'fD I 0051) fl SR3LAL SQUARE TO ROUND ADAPTOR (SHIPPED LOOSE) ❑ AMD - ALUM. CONSTRUCTION WITH FACE OPERABLE ALUM DAMPER (SHIPPED LOOSE) F RAME AND PANEL AVAILABLE IN STEEL (3P, 4P, 1 71') 11 TRV THROW REDUCING VANE OR IN AI UMINUM (3PA, 4PA, 17PA) ❑ SR8E SQUARE TO ROUND ADAPTOR (SHIPPED MOUNTED) FNSIt WIIH SIELL BUI ILK LY VOLUME CONIROL DAMPER X B12 WHITE (OPTIONAL FINISHES AVAILABLE) (SHIPPED LOOSE) DAMPERS ARE ONLY AVAILABLE IN DUCT SIZES 4 10 15 ❑ SR9 SQUARE TO ROUND ADAPTOR (SHIPPED MOUNTED) WITH RADIAL DAMPER (SHIPPED LOOSE) FRAME& f1 R6 INSULATION (ALL FRAME TYPES EXCEPT 6 AND 33) ACE MOUNT ❑ 33 T -BAR ❑ 38 TSAR X 0 BEVELLED ❑ 17 FNS to CFR INC, INC, CEILING MODULE CEIUNG MODULE CEILING OPENING CEILING M 0 0 E - D +3rx + "(8' I - - D + 1" (25) 0 + 6" 152) 6;6" 1/4" (6) e . rIa gi ii 0 ' L 1 l� - /. (22) ' 1 t I OA on 14 0 • 53'4 (147) 0 + 0 2%'(70) U + "(147) SMD = D + 5 (127) OA = CEILING F L AMD = D + 5 34) MODULE - % "(1 • PANELS: X 3P T -BAR I • SPUME ❑ 17P FINELP E ❑ 3PA ❑ 4P U 1YPA 4, CEILING MODULE L CEILING ' : LE CI.ILING • : I i NOM. 1/4" = PANEL MODUL u � . II 9/115-(14) 345" (9) .; O 5'+t (8) 4's � (9) • i .� �I on (1 6'4) I. PANEL OVERALL ONLY PANEL D ■ , I - CEILING MODULE - 1/4 "(6) = CEII ING MQDIA F - slit CsY WHKk+ SIDES Al I METRIC OIMFNSIONS ( ) ARF SOFT C1)NVFRTFO. IMPFRW Oi1FNSIONS ARF C.ONVFRTFO TO METRIC ANO ROIINIWO TO IMF NFARFST Mg I IMFTFR PROJECT: pricE6 ENGINEER: SMD /AMD CUSTOMER: 218791 MODULAR SUBMITTAL DATE: ISPEC. SYMBOL: 2oto /os /27 CEIUNG DIFFUSER CO Copyright E.+PRICE LIMITED 2010 SHEET 1 OF 2 REV S price® Submittal Sheet AVAILABLE DIFFUSER SIZES: 1 SURFACE MOUNT & 6 BEVELLED 17 FlNEUNE MIN. SQUARE NECK MIN. ROUND NECK MODULE • •'E NECK B�P16 6x6 (152x152) 4 SW2) 12x12 (305x305) 6x6 (1 ._,. AI 4 5,f (102,127,152) MAX. SOUARI NICK MAX. ROUND NI CK 24x24 18x 18 (457x157) 15 16 1 H 24x24 (610x610) - 24 (610) (203.254,305,357,. 5 CUEING 33 T —BAR ) ULE SQUARE NI I ROUND NrCK 12x12 05) 9x9 (229)(229) 6,7,8,9 (1S2,178,703,7 24x12 (610x30 21x9 (533)(229) 6,7.8,9 152,178 ,229 12,1 J,16,18,2O 24x24 (610)(610) 21x 33x533) (3 r, ,,7,381,406,457,508) CEILING 4 - • T - BAR maw V SQUARE NE ROUND NECK 12x12 (305x305) 6x6 - x152) , • (102,127,152) 24x12 (610x305) (457x152) • 24x24 (610x• : 18x18 (457x457) 8,10,12, 18 (203,254,305,3355 7,381, 457) 3 {762x762) 24x24 (610x610) 12,14,15,16,18,20,22,24 ( 305 ,357,381,406,457,508,559 CEILING 3P /3PA T - 8AR PANEL MODULE SQUARE NECK RECTANGULAR NECK ROUND NECK 6x6,9x9,12x12,15x15 15x12,15x9,15x6,12x9,12x6,9x6 4,5,6,7,8,9,10,12,14,15 24x24 (610x610) ( 152x152 ,229029,305x305,381x381) (381x305,381x229,381x152, (102,127,152,178,203, 305x229,305x152.229x152) 229,254,305,351.381) 4P 4PA SPUNE & 17P I7PA F1NEUNE PANEL MODULE UAKL NECK LCK 12x12 (305x305) 6x6 (15 x 4,5,6 (102,127,152) x .15x15,18x18 , ,' • 0,12,14,15,16.18 24x24 61 152x152, 229x229 ,305x305,381x381,457x457) (102,127,152,178,203,229,254, 7 AVAILABLE CORE STYLES: IlI '�I ► �� , ■ 1 1101111P. • SQUARE CORE STYLES • • 1S 2S 20 3A 4A I I _ ► I .1 I ► • I■ .5411 ► , Ih (d ► I RE CTANGIA AR CORI STY! f I IA 18 2A 2B • 2C 2D 2E 2F I A • • • • l h . 'III ► ' II�� I► • 1�� I — 311 • 3A2 38 • 3C 3E I NOTES: tel < r < I. W - N • < • DIRECTIONAL CORE REMOVABLE AT DIFFUSER FACE • RECTANGULAR UNITS ARE AVAILABLE IN LISTED DUCT I' ' ► Ill ► ► ( DIMENSIONS EXAMPLES: 12" X 6" (305 X 152) 48 _ 4C 4E• I • CORE STYLES SHOWN ARE PLAN VIEW Al I POW; f)IMFNSMNS ( ) ARF SOFT CONVFRTFt) IMPFRW MMFNSIONS ARF CONVFRTFf TO IAFTRIC ANO ROIjNOFf TO IMF NFARFST MII I MFTFR PROJECT: pricE6 ENGINEER: �/ SMD /AMD CUSTOMER: 218791 ' MODULAR SUBMITTAL DATE: ISPEC. SYMBOL: 2oto /os /27 CEILING DIFFUSER ® Copyright E.H,PRICE LIMITED 2027 SHEET 2 OF 2 REV S prICL® Submittal Sheet SR ROUND NECK ADAPTOR NOM. DIFFUSER LISTED SIZE B I— D- 1/8 "(3) --1 3/4 "(19) MIN . ` Ill 3/4 " f 4 ❑ SR C � i _ sX , CI SR9 . . . � L _ i i i i . . NOM. DIFFID SIZE VCRVCR!) D UCT SIZE B Imo- D-1/8"(3) LISTE �I 6 5 1/2 (140) 3/4 "(1) MIN 8 7 1/2 (191) 10 9 1/2 (241) 2 5/16" 12 11 1/2 (292) (59) 1 1/2 "(38 F 1 14 13 1/2 (343) T CI SR2 i � i 1 z ❑ SR3AL .0 • � %� � � � VCRSE DUCT SIM A . L-- 1 " - -_ - --el- -1. ___ ___ NN■. - -N1--- ''� -s'! - -J 4 1 3/4 (44) L6— NOM. SIZE --' 5 2 1/4 (57) 6 2 3/4 (70) , DAMPER BLADES 7 3 1/4 (82) FULLY OPEN POSITION - -- 'PO CI' 8 3 3/4 (95) 3/4 "(19) MIN I`aA } 10 4 3/4 (120) 12 5 3/4 (146) 3/4 '(19) + 14 6 3/4 (171) } 1 I ' ' 7 15 7 1/4 (184) Rd Hot Sin Nom. Sirs 4,5,6 6 x 6 NOTES: 5,6,7,8 8 x 8 ID SR 3/4" DEEP SQUARE TO ROUND ADAPTOR ONLY MATERIAL 5,6,7,8,9 9 x 9 • COATED STEEL 5,6,7,8,9,10 10 x 10 ❑ SR2 2 5/16" DEEP SQUARE TO ROUND ADAPTOR ONLY SR3 SQUARE TO ROUND ADAPTOR WITH FINISH: 5,6,7,8,9,10 12 x 12 ❑ 5,6,7,8,9,10,12,14 14 x 14 COATED STEEL OPPOSED BLADE DAMPER • MILL X SR3AL SQUARE TO ROUND ADAPTOR WITH 5,6,7,8,9,10,12,14,15 15 x 15 ALUM OPPOSED BLADE DAMPER 5,6,7,8,9,10,12,14,15,16 16 x 16 ❑ SR8E SQUARE TO ROUND ADAPTOR WITH 5,6,7,8,9,10,12,14,15,16,18 18 x 18 STEEL BUTTERFLY VOLUME CONTROL DAMPER. 6 18 x 6 DAMPERS ARE ONLY AVAILABLE 5,6,7,8,9,10,12,14,15,16,18,20 20 x 20 IN DUCT SIZES 4 TO 15 5,6,7,8,9,1 0,12,14,15,16,18,20,21 21 x 21 ❑ SR9 SQUARE TO ROUND ADAPTOR WITH 5, 6,7,8,9,10,12,14,15,16,18,20,22 22 x 22 RADIAL DAMPER ACCESSORY 5,6,7,8,9,10 22 x 10 • FACTORY TOLERANCE: ±1/32 "(1) 5,6,7 ,8,9,10,12,14,15,16,18,20,22,24 24 x 24 ALL METRIC DIMENSIONS ( ) ARE SOFT CONVERTED. IMPERIAL DIMENSIONS ARE CONVERTED TO METRIC AND ROUNDED TO THE NEAREST MILLIMETER. PROJECT: Burgerville TI Pacific Hwy p rIE ® ENGINEER: W SR CUSTOMER: 222044 ROUND NECK ADAPTOR SUBMITTAL DATE: 4/11/2012 SPEC. SYMBOL: 2010/02/11 © Copyright E.H.PRICE LIMITED 2010 REV I • 3r "E" Submittal Sheet RCD, A ADJUSTABLE AIR PATTERN ROUND CEILING DIFFUSERS •+ DIFFUSER OVERALL DIA = A CEILING OPENING DIA = B — NOM. DUCT SIZE = D T all NECK = D- 1 /32 "(1) «t iii (19) E =OPEN —�_ F }CLOSED • IMPERIAL UNITS (Inches) SI UNITS (mm) 5�E A B C D E F 511 A B C D E 6 13 12 1 6 1 X 6 305 41 152 44 24 8 18 16 2 8 2 1 8 457 406 54 203 30 10 221/2 20 _ 2 _ 1 0 2 1 10 572 • • 67 254 68 37 12 27 24 3 12 3 1% 12 686 610 83 5 79 41 14 311/2 28 3 14 3 1 14 800 711 • . 356 100 49 16 36 32 4 16 4 21/4 16 914 813 18 406 108 57 18 40 36 4/j 18 4 2 18 1029 91 124 4 121 64 20 45 40 5% 20 51/4 2 20 1143 116 137 508 133 70 24 54 48 6 24 6 3 24 1 1219 165 610 1 ' 83 30 671/2 60 8 30 7 3 30 715 1524 203 762 184 N, 36 671 60 8 36 7 39'16 1715 1524 203 914 184 _ 9 MATERIAL • HEAVY GAUGE STEEL B12 WHITE (OPTIONAL FINISHES AVAILABLE) FACTORY TOL: • ± 1 /22' (1) RCD, 3 POSITION ADJUSTMENT O RCDA, FULLY ADJUSTABLE ALL METRIC DIMENSIONS ( ) ARE SOFT CONVERTED. IMPERIAL DIMENSIONS ARE CONVERTED TO METRIC AND ROUNDED TO THE NEARES? PILL METER. PROJECT: price® Burgerville TI Pacific Hwy ENGINEER: RCD,RCDA CUSTOMER: 210473 ADJUSTABLE AIR PATTERN ROUND CEILING DIFFUSERS SUBMITTAL DATE: 4/11/2012 SPEC. SYMBOL: MAY 97 © c gnt E. H. PRICE LMITEC '997 REV C prIIE ,..,, ,,,,,._,_„... ,.., ,,_.,,,,,,,,_ . ‘,..:__J,L...,...! L L _ L i. ■L- L._. _ v.....-•_ _',-•:•-_ Q.- MODEL VCR7 RADVIL OPPOSED BLADE DAMPER TYPICAL SCREW MOUNTING LOCATIONS • (NOT REQUIRED FOR R.I.D. APPLICATION) - -- THREE SEGMENT BLADE FOUR SEGMENT BLADE , CONFIGURATION I NiON 46 \'11 1111 / / 1 n__- A SIZE 6 -12 I SIZE 14 -20 MOUNTING OF DAMPER THROUGH FRAME d INTO DUCT - FROM INSIDE OUT. L OCATE SCREWS BELOW BLADE HINGE I go le B I / \ / \' B 111' C II 7 II HOLE FOR OPERATOR NI1/4. MOUNTING TABS MOUNTING TABS ROD EXTENSION ( (3) NOTE: VCR7 RADIAL OPPOSED BLADE VOLUME CONTROL DAMPER WITH ROLLED BORDER SLEEVE (SIZE 14 -36) FOR DUCT MOUNTED INSTALLATION. NOM. IMPERIAL UNITS Si. UNITS FOR MINIMUM HEIGHT, MOUNT DAMPER DIRECTLY TO SIZE A B C B DIFFUSER USING CORRECT HOLES IN MOUNTING TAB. " 5 4" - 14: 102 THREE SEGMENT BLADE CONFIGURATION FOR SIZES 6 -12 (SHOWN ABOVE) - FOUR SEGMENT BLADE CONFIGURATION FOR SIZES 14 -20 (SHOWN ABOVE) 8 7 4 - 198 124 - SIX SEGMENT BLADE CONFIGURATION FOR SIZES 24,30 &36 (NOT SHOWN) 10 913/16" 5 - 249 146 - 12 11 6 - 300 67 - MATERIAL: 14 13 4 2 352 1. 54 COATED STEEL 15 14 5 2 378 I 54 OPTION: 16 15 5 2 403 143 54 OPERATOR ROD E • , k • • I FROM UNDERSIDE, 18 17/8" 6'/ + 2 454 159 54 AS INDICATED 1 : ` 20 19 7" Vie 50 178 4 24 237/6' 6 213/16 61. 172 30 29 8 2' 59 210 72 36 35 9 2 911 248 72 ALL METRIC DIMENSIONS ( ) ARE SOFT CONVERTED. IMPERIAL DIMENSIONS ARE CONVERTED TO METRIC AND ROUNDED TO THE NEAREST MILLIMETER. PROJECT: Burgerville TI Pacific Hwy ri ENGINEER: W VCR7 CUSTOMER: RADIAL OPPOSED BLADE 223934 DAMPER SUBMITTAL DATE: 4/11/2012 'SPEC. SYMBOL: JUNE 2009 © Copyright E.H.PRICE LIMITED 2009 REV C pricee SubIirmot Sll*heett. 500 SUPPLY GRILLES & REGISTERS ' BORDERS: f• D — DUCT SIZE X F FLAT D — OPTIONAL OPPOSED {,__ 1 Y.. BLADE DAMPER ` I j I ( - ff T J 0510 rI I 1 1/2 (38) 3f6 (5) i ll 1 X32 "( H • t O 520 , I I I I 1 111 1 I, � 2 sz "(53) I N NARROW g = I -, A = D 3/4" (19) B i ---I 1" (25) r— OVERALL — A + 2B ` 7 051 0 ir " (5 � H MODEL 510 MODEL 510D 1 51 (34) • 520 )S2" (52) MATERIAL NOTE: • SILEL CONSTRUCTION • STANDARD CONSTRUCTION WITH A MULLION: STING +'AMES: A MULLION IS PROVIDED WHEN NOMINAL SIZE u D FINS,t GRILLE DIMENSIONS EXCEED 24" (610) FOR UNIVrN NOMINAL SI71 CR11 I F DIMENSIONS X B12 WHITE EG. 45X6 THE MULLION IS POSITIONED Vi(12) r• UCI SI L 1 21/2 "(64) FROM THI? CENTRE OF THE GRILLE. (OPTIONAL FINISHES AVAILABLE) . • INDIVIDUALLY ADJUSTABLE BLADES .// /// I / OPTION • TYPE A FASTENING — COUNTERSUNK �� (9) X C/W COATED STFFI OPPOSmD SCRE WI I01 I S f OR NO.8 S.M.S. PI R BLADE DAMPER FACTORY STANDARD (SCREWS SUPPI LED) / DkCT + 3 /15 "(5) (SPECIFY 510D OR 5200) • AVAILABLE SIZES . 0 T + 1/4" (6) O IS — INSECT SCREEN, 18/16 MESH MIN. — 6" X 4" 152 X 102) USE WITH F BORE R (NOT RECOMMENDED WITH OPTIONAL MAX. — 48" X 48 (1219 X 1219) OPPOSED RLADF DAMPER) (ONL PIECE CONSTRUCTION) C] T DUCT SIZE + "(51) • OVERSIZE UNITS AVAILABLE C/W NARROW FLANGE OR DUCT CHANNEL • BLADE ORIENTATION — FRONT SET M1 " (8) j - S = PARALLEL TO SHORT DIMENSION I.9—DUCT — 'Hb " (1.S USE WfTH N BORDER oft DUCT SIZE 4, STYLES: S S10 /L X 520/L • TENING: ❑ C— ONCEALED BRACKET ❑ 510 - ❑ 520/S 1 P lir I ' a -' 3 /4` s / I 3 /4 �. (19) �. r (1'9) �I I .- (19) ` 1 a I MFTRIC. MMFNSIONS ( ) ARE SOFT CONVFRTFh IMPFRIAl flIMFNSIONS ARP CONVFRTFI) TO MFTRIC AND ROUNDED TO THE NFARFST MII I )AFTER PROJECT: price° ENGINEER: W 510/520 STEEL SUPPLY CUSTOMER: 219693 GRILLES Sc REGISTERS SUBMITTAL DATE: (SPEC. SYMBOL: 2011/10/20 © Copyright E.H.PRICE LIMITED 2010 SHEET 1 OF 2 REV I prow Submittal Sheet 80 RETURN GRILLES & REGISTERS (s W) SIDEWALL APPUCA710N OVERALL = D + 1 9f6" (43) 1 Y4 (32) OPEN = D - 1 )( e "(21) 1 Y: (32) 1 r r4 "(6) - 1/2" 11 " 13) _� L 1 "(25) 1 11 ••••��IIiiI\S����� 1 1 X (27) 1 ❑ F FLAT FACE I ji • C CURVED FACE BOR' ' I :ORDER OPTIONAL OPPOSED _— D = NOMINAL DUCT ---1 BLADE DAMPER (L I ) LAY—U4 APPUCATION X F T —BAR LAY —IN • NARROW FRAME ❑ CH CHANNEL ❑ 80 CORE CM = CEILING MODULE D = CM — 2" (51) CM = CEILING MOP' tl I D = CM — 1 "(25) 1 1EILINC MOD . CM = CEILING MODULE ,• I q q II (25) I... N( 1111... "(13) — 1--1 1/4" (32) . 11" (3) OVERALL 1+-1" ( 16" (3) 1b )6" (3 OVERALL = CM - +I: (8) = CM - ,ii (8) = CM OVERALL (6) = C M — )4" (6) ❑ TIRO OPTION FRAM (NOM. DUCT SIZE 22" X 22" ONLY) B12 WHITE (OPTIONAL FINISHES AVAILABLE) 21 Y4" (552) — 1 TLRD MATERIAL: • ALUMINUM CONSTRUCTION 11‘11111111111PPAIIIII 7 Y4 (184) 80 RETURN GRILLE MAX. `�� (F FRAME T —BAR NOTES: 1 IM ■ —MM ■_� LAY —IN ONLY • TYPE A FASTENING — COUNTERSUNK 1 I SCREW HOLES FOR NO.8 S.M.S. PER 1 Y4 "(32) NOM. SIZE di (21) I� FACTORY STANDARD (SCREWS SUPPLIED) • AVAILABLE SIZE: OVERALL = 23 1 )(e" (602) MINIMUM DUCT SIZE = 6" X 4" (152 X 102) MINIMUM DUCT SIZE NF FRAME = 6" X 3" (152 X 76) MAXIMUM WITHOUT MULLION 48" X 24" (1219 X 610) OPTS • OVERSIZED GRILLE WITH MULLION AVAILABLE UP TO • FOR OPTIONAL MOUNTING OR BORDERS 96" 48" (2438 X 1219) ONE PIECE FRAME CONSTRUCTION REFER TO SHEET 2 • UNITS OVER 96" X 48" (2438 X 1219) SUPPLIED IN SECTIONS * MODEL 80DAL c/w ALUMINUM OPPOSED c/w DUCT MOUNTING CHANNEL BLADE DAMPER NOT AVAILABLE WITH CH & 80 CORE • CH (CHANNEL) UNITS OVER 48" X 24" (1219 X 610) MODEL 80D c/w STEEL OPPOSED BLADE SUPPLIED IN MULTIPLE SECTIONS ❑ DAMPER B17 BLACK FINISH • CORE ONLY UNITS MAXIMUM SIZE 48" X 24" (1219 X 610) ALL METRIC DIMENSIONS ( ) ARE SOFT CONVERTED. IMPERIAL DIMENSIONS ME CONVERTED TO METRIC AND ROUNDED TO THE NEAREST MIWMETER. PROJECT: price* Burgerville TI Pacific Hwy W ENGINEER: 80 SERIES ALUMINUM RETURN CUSTOMER: 222015 GRILLES & REGISTERS SUBMITTAL DATE 4/11/2012 SPEC SYMBOL: C R 2011/02/28 © Copyright E.H.PRICE LIMITED 2011 SHEET 1 OF 2 REV 0 APR 2 7 2012 Phone: 503-234-5071 GD1\100 JONS ®N 2220 SE Ninth Ave., Portland, OR 97214 BUILD��.. G D1\10011 AIR PRODUCTS Fax: 503 - 233 -0451 • 800- 848 -5199 ;07, SUBMITTAL PROJECT: Burgerville T.I. LOCATION: Tigard, Oregon ARCHITECT: ENGINEER: Hood - McNees Inc. CONTRACTOR: Plumbing & Mechanical Contractors DATE SUBMITTED: April 11, 2012 PROJECT MANAGER: Ron Enkelis EMAIL: renkelis. ohnsonair.com ACCOUNT MANAGER: EMAIL: PLAN DATE: March 1, 2012 ADDENDUMS: None WE ARE PLEASED TO SUBMIT THE FOLLOWING LIST OF EQUIPMENT FOR APPROVAL. BASED UPON INFORMATION RECEIVED WE BELIEVE THIS MATERIAL CONFORMS TO THE SPECIFICATIONS. IT SHALL REMAIN THE CONTRACTOR'S RESPONSIBILITY TO VERIFY SIZES AND QUANTITIES PRIOR TO ORDER RELEASE. MATERIAL WILL BE RELEASED TO PRODUCTION UPON RETURN OF APPROVED SUBMITTALS TO JOHNSON AIR PRODUCTS AT 2220 S.E. 9TH AVE.. PORTLAND, OREGON 97214. MATERIAL SUBMITTED: Exhaust Fans SPECIFICATIONS: MANUFACTURER: Greenheck (Please see attached literature) SUBMITTAL Job Title: BURGERVILLE TI PACIFIC HWY Date: 04/11/12 Submitted By: Ron Enkelis JOHNSON AIR PRODUCTS 2220 SE NINTH AVE PORTLAND , OR 97214 -4661 US Phone: (503)234 -5071 Fax: (503)233 -0451 Email Address: renkelis @johnsonair.com EIGREENHECK Building Value in Air. P.O. Box 410 Schofield, WI 54476 (715) 359 -6171 FAX (715) 355 -2399 www.greenheck.com CAPS 4.8.1006 G:1Job Data Files\Aaron C\Secured Jobs 20121A- FIBURGERVILLE TI PACIFIC HWY.gcj Page 1 of 8 DIGREENHECK Printed Date: 4/11/2012 Job: BURGERVILLE TI PACIFIC HWY Building Value in Air. Product Type: Fan Mark: • EF -1 6 SP Diameter 10 1� Ceiling Exhaust Fan �, Tag EF -1 �� STANDARD CONSTRUCTION FEATURES • Corrosion resistant galvanized steel scroll and housing • White designer non - yellowing grille • Round outlet duct collar with integral backdraft damper • Single inlet forward curved wheel • Plug type disconnect • Adjustable mounting... 13.875 11.5 SELECTED OPTIONS & ACCESSORIES UUcUL 507 Listed - "Electric Fans" Roof Cap, Curb Mounted, (PN: RCC -7) Shipped Loose Roof Curb, GPI- 15-G12 Designer Grille �4•■,„ Polypropylene Wheel Material �2 3 5 NOTES: All dimensions shown are in units of inches DIMENSIONS Approx. Fan Weight (lb) 29 PFRFORMANCF (Flevatinn ft = f1 Airstream T .mperature = = 7f1) Motor Information Qty Model Volume SP (in w g) FRPM Watts- Amps - (CFM) (RPM) (W) (A) V /C /P End: RPM 2 SP -B150 154 0.25 1,050 129 1.7 115/60/1 ODP 1050 SQIINn Inlet Sound Power by Octave Band Lwa dBA Spherical LwA - A weighted sound power level, based on ANSI S1.4. 62.5 125 250 500 1000 2000 4000 8000 Sones Sones calculated using AMCA 301 at 5.0 ft in a spherical field. 55 62 54 55 54 47 42 36 57 46 3.0 dBA - A weighted sound pressure level, based on 11.5 dB attenuation per octave band at 5.0 ft. Sones are at 0.1 inches of wg dBA levels are not licensed by AMCA International. 1.4 CIft1CCI memo • WNW • 1.0 IOID IP OM 0 . 8 _ RIR • fOYEMERT ARD CORTROI RETOCIAT IOn PI 0.6 IRTERRATIORAL IRC Y — 0.4 • N — Y _ 0.2 - U) _ N _ S 0.0 I • L • I 1 ..1. _ .I t— • r te 'T' t i I I E I I 1 I I 0 20 40 60 80 100 120 140 160 Volume (CFM) _ _ RPM Curv. • • • System Curve Brake Power Curve Do not .elect to the lel of this surge curve CAPS 4 8.1006 G:1Job Data FileslAaron C\Secured Jobs 20121A- FIBURGERVILLE TI PACIFIC HWY.gcj Page 2 of 8 L GREENHECK Job: BURGERVI TI PACIFIC / HWY Building Value in Air. Product Type: Fan Mark: EF -1 AMCA amca CERTIFIED RIITIAGS SOURD anD RIR PERICRMACICE RIR MOVEmEAT AAD COATROI AffOCIATIOA IATERAATIOARI. inc. AMCA Licensed for Sound and Air Performance. Power rating (BHP /kW) does not include transmission losses. Greenheck Fan Corporation certifies that the model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. Performance certified is for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of an inlet grille and backdraft damper. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are for loudness values in spherical sones at 5ft. (1.5m) in a spherical free field calculated per Annex B of AMCA 311. Values shown are for installation type B: free inlet spherical sone levels. The AMCA Certified Ratings Seal applies to sone ratings only. CAPS 4.8.1006 G:1Job Data Files\Aaron C\Secured Jobs 20121A- FIBURGERVILLE TI PACIFIC HWY.gcj Page 3 of 8 j GREENHECK Job: BURGERVILLE Ti PACIFIC / HWY Building Value in Air. Product Type: Fan Mark: EF -1 RCC -7 Roof Cap Curb STANDARD CONSTRUCTION FEATURES • Weathertight aluminum construction • Integral birdscreen • Built in curb cap. 12 4 7 a 10 6.375 0 1.5 0 15 NOTES: All dimensions shown are in units of inches CAPS 4.8.1006 G:\Job Data FileslAaron C\Secured Jobs 20121A -F \BURGERVILLE TI PACIFIC HWY.gcj Page 4 of 8 , r JGREENHECK Printed Date: 4/11/2012 Job: BURGERVILLE TI PACIFIC HWY Building Value in Air. Product Type: Fan Mark: EF -2 6 SP Diameter /�` Ceiling Exhaust Fan � � � ) 7 Tag EF-2 � � STANDARD CONSTRUCTION FEATURES L, • Corrosion resistant galvanized steel scroll and housing • White designer ...J non - yellowing grille • Round outlet duct collar with integral backdraft damper • Single inlet forward curved wheel • Plug type disconnect • Adjustable mounting 13.875 11.5 brackets • Energy Star Compliant �� SELECTED OPTIONS & ACCESSORIES UL /cUL 507 Listed - "Electric Fans' Roof Cap, Curb Mounted, (PN: RCC -7) Shipped Loose Roof Curb, GPI- 15 -G12 ../4""-., Designer Grille 14.87 Polypropylene Wheel Material Energy Star Rated 13.25 NOTES: All dimensions shown are in units of inches ' DIMENSIONS Approx. Fan Weight (lb) 28 PFRFORIIANCE (FlPvatinn ft = ('< Airqtrpam T.mperature = = 70) Motor Information Qty Model Volume SP (in wg) FRPM Watts— Amps — (CFM) (RPM) (W) (A) V /C /P End: RPM 1 SP -B70 57 0.25 675 45 0.5 115/60/1 ODP 675 SAIINf Inlet Sound Power by Octave Band Lwa dBA Spherical LwA - A weighted sound power level, based on ANSI S1.4. 62.5 125 250 500 1000 2000 4000 8000 Sones Sones calculated using AMCA 301 at 5.0 ft in a spherical field. 46 54 50 53 48 40 30 27 52 41 2.0 dBA - A weighted sound pressure level, based on 11.5 dB attenuation per octave band at 5.0 ft. Sones are at 0.1 inches of wg dBA levels are not licensed by AMCA International. 0.7 ' M1ClA 0.6 e ' OW$flID i 0.5 _ _ yp�Ap — ° ' AIR 0.4 RIR — . MOVEIRMT — RRD OORTROI •TOCIRTIOR 3 0.3 IR IIITERIIIITIORtII. inc C Y — 0.2 b — r a. — i' u 0.1 - N — _ • 0.0 1. •1 1 .. 1 • f I I I I 1 I I I 1 I t 1 1 I 1 1 I I 0 10 20 30 a0 50 60 70 80 ENERGY STAR Volume (CFM) • _ ■ RPM Curve • • System Curve — — — Brake Power Curve Do not select to the left of this surge curve CAPS 4 8.1006 G:\Job Data Files\Aaron C\Secured Jobs 20121A- F \BURGERVILLE TI PACIFIC HWY.gcj Page 5 of 8 Printed Date: 4/11/2012 GREENHECK Job: BURGERVILLE TI PACIFIC HWY Building Value in Air. Product Type: Fan Mark: EF -2 AMCA amca CERTIFIED RATIAG% SOURD ono AIR PERrORMAncf U AIR mOVEIEI1T (MD conTROI ntrocifTion IATERAATIOAAI. Inc. AMCA Licensed for Sound and Air Performance. Power rating (BHP /kW) does not include transmission losses. Greenheck Fan Corporation certifies that the model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. Performance certified is for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of an inlet grille and backdraft damper. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are for loudness values in spherical sones at 5ft. (1.5m) in a spherical free field calculated per Annex B of AMCA 311. Values shown are for installation type B: free inlet spherical sone levels. The AMCA Certified Ratings Seal applies to sone ratings only. CAPS 4.8.1006 G: \Job Data Files\Aaron C \Secured Jobs 2012\A -F \BURGERVILLE TI PACIFIC HWY.gcj Page 6 of 8 L GREENHECK Printed Date: 4/11/2012 Job: BURGERVILLE TI PACIFIC HWY Building Value in Air. Product Type: Fan Mark: EF -2 RCC -7 Roof Cap Curb STANDARD CONSTRUCTION FEATURES • Weathertight aluminum construction • Integral birdscreen • Built in curb cap. 12 7 - 10 6.375 V V 1.5 A 15 0 NOTES: All dimensions shown are in units of inches CAPS 4.8.1006 G: \Job Data Files\Aaron C \Secured Jobs 2012\A- F \BURGERVILLE TI PACIFIC HWY.gcj Page 7 of 8 I GREENHECK Printed Date: 4/11/2012 Job: BURGERVILLE TI PACIFIC HWY Building Value in Air. GPI Roof Curb Actual L STANDARD CONSTRUCTION FEATURES A> tl W • Welded Aluminum (0.064 in) or galvanized (18 ga) construction • Straight sided • 2 in roof mounting flange • 1 in 3# density insulation • Wood nailer. o greater Roof than Opening the - "ActualThe " top Maximum outside roof opening dimension dimension minus 2 shin. W uld ith not dampers , the Minimum roof opening dimension should be at least 2.5 in more than the damper dimension. NOTES: * The Roof Opening Dimension may NOT be the Structural Opening Dimension. * Maximum single piece shipping length is 76 . • Security Bars are optional and must be specified. They are 0.5 in steel, and will be placed 6 in on center. These bars are welded to the frame, and the frame is welded to the curb. To prevent corrosion, they are coated with p Greenheck's high performance Permatector coating. Security Bars are in lieu of damper and damper tray. NOTES: All dimensions shown are in units of inches Mark Cap Actual Flange Hei ht Damper Tray WxL WxL WxL g WxL E F - 2 15 x 15 13.5 x 13.5 17.5 x 17.5 12 EF -2 1 15 x 15 13.5 x 13.5 17.5 x 17.5 12 CAPS 4.8.1006 G:Uob Data Files\Aaron C\Secured Jobs 20121A- FIBURGERVILLE TI PACIFIC HWY.gcj Page 8 of 8 I