April 12, 2012
GPD Project #: 2012793.58
MONOPOLE
STRUCTURAL ANALYSIS REPORT
P001373B GREENBURG
11744 SW Pacific Hwy
Tigard, OR 97223
GPD Project #: 2012793.58
New Antenna Installation
Existing 130 ft Monopole
For:
T- Mobile Towers
Bellevue, Washington
Prepared By: AltGil PR
g
i Pote 9 �
OREGO�
4q AFC. e.
� f� B. GRIm—
David B. Granger, P.E.
Registered Professional Engineer
Oregon #: 18155PE
April 12, 2012
Glaus, Pyle, Schomer, Burns and DeHaven, Inc. dba GPD Group ENGINEERS • ARCHITECTS • PLANNERS
520 South Main Street • Suite 2531 • Akron • Ohio • 44311 -1010 • Tel: 330 - 572 -2100 • Fax: 330-572 -2101
TABLE OF CONTENTS
DESCRIPTION PAGE NUMBER
EXECUTIVE SUMMARY 1
TOWER DESCRIPTION 2
TOWER MATERIALS 2
TOWER LOADING . 3
ANALYSIS 4
CONCLUSIONS AND RECOMMENDATIONS . 5
DISCLAIMER OF WARRANTIES . 6
APPENDICES
1. TNXTOWER ANALYSIS PRINTOUT
2. TOWER ELEVATION DRAWING AND FEEDLINE PLAN
3. ANCHOR ROD AND BASE PLATE ANALYSIS
4. FOUNDATION ANALYSIS
,0/a GPD GROUP
P001373B GREEN BURG
EXECUTIVE SUMMARY
The purpose of this analysis was to verify whether the design for the existing tower is structurally capable
of carrying the new antenna and coax loads as specified by Verizon to T- Mobile Towers. This report
was commissioned by Mr. Kenneth Fann of T- Mobile Towers.
IThe design of the existing 130' monopole meets the requirements of the TIA -222 -G standard and the
2 010 Oregon Structural Specialty Code (OSSC) for a 95 mph 3- second gust wind speed with no ice and
a 30 mph 3- second gust wind speed with 1" of radial ice, as well as the seismic provisions set forth by
TIA -222 -G in accordance with the 2010 OSSC, for the proposed antenna configuration.
The foundation reactions, with the proposed antenna configuration, were found to be less than the
capacity of the existing foundation design. Therefore, the existing foundation is adequate assuming it
was properly constructed according to original design.
The proposed coax shall be banded flush to the tower in (2) rows of (6).
Section Results
Monopole °A) Capacity Result
80.9' — 130' 77.7% Pass
45.9' — 80.9' 86.8% Pass
0' — 45.9' 90.2% Pass
Base Plate 45.3% Pass
Anchor Rods 80.1% Pass
Foundation °A° Capacity Result
Structure 82.1% Pass
Soil Interaction 87.7% Pass
Tower Rating: 90.2%
��� G PD GROUP STRUCTURAL ANALYSIS REPORT PAGE 1
P001373B GREENBURG
TOWER DESCRIPTION
The existing 130' monopole is located in Tigard, Oregon. It was originally designed for Western
Wireless PCS by Valmont Industries, Inc. of Valley, Nebraska. The original design load for the tower
was for an 85 mph fastest -mile wind speed with 1/2" radial ice.
The monopole has three major sections connected by slip joints. It has 12 sides and is evenly
tapered from 41" (flat -flat) at the base to 14.76" (flat -flat) at the top. The structure is galvanized and
has no tower lighting.
DOCUMENTS PROVIDED
Description Remarks Source
Structural Calculations Valmont, dated 6/21/1996 T- Mobile
Construction Drawings David Evans and Associates, dated 9/11/1996 T- Mobile
Foundation Calculations Miller Consulting Engineers Job #: 960455, T- Mobile
dated 6/28/1996
Geotechnical Report Dames and Moore Job #: 32140- 001 -016, T- Mobile
dated 6/18/1996
Previous Analysis GPD Group Project #: 2006192.92, GPD
dated 12/6/2006
TOWER MATERIALS
Data on steel strength was available from the information provided. The following table details the steel
strength used in the analysis.
Monopole ASTM A572 (65 KSI Yield Strength)
Base Plate ASTM A633 (60 KSI Yield Strength)
Anchor Bolts ASTM A615 (75 KSI Yield Strength)
aa'*- GPD GROUP STRUCTURAL ANALYSIS REPORT PAGE 2
P001373B GREENBURG
TOWER LOADING
The following data shows the major loading that the tower supports. Existing, reserved, and proposed
antenna information was provided by T- Mobile Towers.
Existing & Reserved Configuration
Elevation Carrier Antennas
127' T- Mobile (12) Andrew TMBXX- 6516 -R2M Antennas &
(12) Andrew ETW190VS12UB TMAs on a
12' LP platform, w/ (24) 1 -5/8" internal coax
117' Cricket (6) CSA PCSS065 -19 -2 Antennas on (3) 10' T -arms,
w/ (6) 1 -5/8" external coax
107' Clearwire (4) Kathrein 840 -10057 Antennas, (4) Nextnet BTS -2500 TMAs,
(4) Radiowaves HP2 -23 Dishes, & (1) Trimble Acutime GPS on
(4) Valmont flush pipe mounts, w/ (9) CAT5 internal cable
100' T- Mobile (1) 4' HP Dish, flush mounted, w/ (1) 1 -5/8" internal coax
90' Verizon (2) Antel LPD -4019, (2) BSA - 185040/12, (2) LPD -6516,
(2) BSA- 185063/12, (2) LPD - 7907/8, & (2) BSA - 185065/12_2
Antennas on a Valmont Platform, w/ (12) 1 -5/8" external coax
Proposed Configuration
Elevation Carrier Antennas
127' T- Mobile (12) Andrew TMBXX- 6516 -R2M Antennas &
(12) Andrew ETW190VS12UB TMAs on a
12' LP platform, w/ (24) 1 -5/8" internal coax
117' Cricket (6) CSA PCSS065 -19 -2 Antennas on (3) 10' T -arms,
w/ (6) 1 -5/8" external coax
107' Clearwire (4) Kathrein 840 -10057 Antennas, (4) Nextnet BTS -2500 TMAs,
(4) Radiowaves HP2 -23 Dishes, & (1) Trimble Acutime GPS on
(4) Valmont flush pipe mounts, w/ (9) CAT5 internal cable
100' T- Mobile (1) 4' HP Dish, flush mounted, w/ (1) 1 -5/8" internal coax
90' Verizon (2) Antel LPD -4019, (2) LPD -6516, (2) LPD- 7907/8,
(2) BXA- 70063/8, (1) BXA185063/12, (1) BXA- 70040 -8CF,
& (1) BXA- 185085/12 Antennas, (1) CSS XP20450D Antenna
& (6) CCDP565 -1 W Diplexers on a Valmont Platform,
w/ (12) 1 - 5/8" external coax
Notes: - BOLD type indicates the proposed carrier's final reserved configuration.
- The proposed coax shall be banded flush to the tower in (2) rows of (6).
- See Appendix 2 for coax layout.
The purpose of this independent structural analysis review is to determine if the design for the existing
tower, with the proposed configuration, is in conformance to the latest TIA -222 -G standard and Oregon
Structural Specialty Code (OSSC) requirements.
��� G PD GROUP STRUCTURAL ANALYSIS REPORT PAGE 3
P001373B GREENBURG
ANALYSIS
The purpose of this structural analysis review is to determine if the design for the existing tower is in
conformance to the latest TIA -222 -G and 2010 OSSC standard requirements. TnxTower (Version
6.0.4.0), a commercially available software program, was used to create a three - dimensional model
of the tower and calculate member stresses for various dead, live, wind, and ice load cases. All
loads were computed in accordance with the ANSI/TIA -222 -G standard and all local building code
requirements. Selected output from the analysis is included in Appendix 1.
The current requirements of TIA -222 -G and 2010 OSCC are for a 95 mph 3- second gust wind speed with
no radial ice and 30 mph 3- second gust wind speed with 1" of radial ice. The 2010 OSCC requires
towers within Washington County, Oregon be analyzed with a 95 mph 3- second gust wind speed.
ANALYSIS 3- SECOND GUST: 95 MPH
ANALYSIS 3- SECOND GUST W/ RADIAL ICE: 30 MPH
RADIAL ICE THICKNESS: 1"
STRUCTURE CLASS: II
TOPOGRAPHIC CATEGORY: 1
EXPOSURE CATEGORY: C
Seismic loads were considered using a substantiated analysis utilizing the TIA -222 -G standard. Based on
section 2.7.3 of the TIA -222 -G standard the seismic effects may be ignored due to the earthquake
spectral response acceleration at short periods (Ss) for this site being less than or equal to 1.00. The wind
effects control the tower loading.
SITE CLASS: D
RESPONSE MODIFICATION COEFFICIENT (R): 1.5
1- SECOND SPECTRUAL RESPONSE ACCELERATION (Si): 0.340
SHORT PERIOD SPECTRAL RESPONSE ACCELERATION (Ss): 0.949
The tower and foundations are assumed, for the purpose of this analysis, to have been properly
fabricated, constructed, maintained, and to be in good condition with no structural defects. This is not a
condition assessment of the tower and has been provided without the benefit of detailed tower photos, a
detailed tower mapping, or a GPD Group site visit. This analysis assumes all antennas and coax have
been installed in a neat and orderly fashion. Proposed antennas are assumed to be installed on standard
sized mounts at 120° azimuths. The existing /proposed mounts are assumed to have been verified by the
carrier to support the existing /proposed loading for the required various load cases.
Ar■- GPD GROUP STRUCTURAL ANALYSIS REPORT PAGE 4
P001373B GREENBURG
CONCLUSIONS AND RECOMMENDATIONS
Based on the computer structural analysis results, the design for the existing 130' monopole meets the
requirements of TIA -222 -G and the 2010 Oregon Structural Specialty Code (OSSC) for a 95 mph 3-
second gust wind speed with no ice and a 30 mph 3- second gust wind speed with 1" of radial ice, as
well as the seismic provisions set forth by TIA -222 -G in accordance with the 2010 OSSC, for the
proposed antenna configuration.
The foundation reactions, with the proposed loading configuration, were found to be less than the
capacity of the existing foundation design. Therefore the existing foundation is adequate, assuming it
was properly constructed according to original design.
The proposed coax shall be banded flush to the tower in (2) rows of (6).
Summary of Findings
Monopole Satisfactory
Base Plate Satisfactory
Anchor Rods Satisfactory
Foundation Satisfactory
Therefore, based on our analysis results, the design for the existing structure is structurally satisfactory
for the proposed loading configuration.
A l GPO GROUP STRUCTURAL ANALYSIS REPORT PAGE 5
P001373B GREENBURG
DISCLAIMER OF WARRANTIES
GPD GRO UP has not performed a site visit to the tower to verify the member sizes or antenna /coax
loading. If the existing conditions are not as represented on the tower elevation contained in this report,
we should be contacted immediately to evaluate the significance of the discrepancy. This is not a
condition assessment of the tower or foundation. This report does not replace a full tower inspection.
The tower and foundations are assumed to have been properly fabricated, erected, maintained, in good
condition, twist free, and plumb.
The engineering services rendered by GPD GROUP in connection with this Structural Analysis are
limited to a computer analysis of the tower structure and theoretical capacity of its main structural
members. All tower components have been assumed to only resist dead loads when no other loads are
applied. No allowance was made for any damaged, bent, missing, loose, or rusted members (above and
below ground). No allowance was made for loose bolts or cracked welds.
GPD GRO UP does not analyze the fabrication of the structure (including welding). It is not possible to
have all the very detailed information needed to perform a thorough analysis of every structural sub-
component and connection of an existing tower. GPD GROUP provides a limited scope of service in
that we cannot verify the adequacy of every weld, plate connection detail, etc. The purpose of this
report is to assess the feasibility of adding appurtenances usually accompanied by transmission lines to
the structure.
It is the owner's responsibility to determine the amount of ice accumulation in excess of the code
specified amount, if any, that should be considered in the structural analysis.
The attached sketches are a schematic representation of the analyzed tower. If any material is fabricated
from these sketches, the contractor shall be responsible for field verifying the existing conditions, proper
fit, and clearance in the field. Any mentions of structural modifications are reasonable estimates and
should not be used as a precise construction document. Precise modification drawings are obtainable
from GPD GRO UP, but are beyond the scope of this report.
Miscellaneous items such as antenna mounts, etc., have not been designed or detailed as a part of our
work. We recommend that material of adequate size and strength be purchased from a reputable tower
manufacturer.
GPD GRO UP makes no warranties, expressed and /or implied, in connection with this report and
disclaims any liability arising from material, fabrication, and erection of this tower. GPD GRO UP will
not be responsible whatsoever for, or on account of, consequential or incidental damages sustained by
any person, firm, or organization as a result of any data or conclusions contained in this report. The
maximum liability of GPD GROUP pursuant to this report will be limited to the total fee received for
preparation of this report.
l GPD GROUP STRUCTURAL ANALYSIS REPORT PAGE 6
P001373B GREENBURG
APPEN DICES
1. TnxTower Analysis Printout
. 2. Tower Elevation Drawing and Feedline Plan
3. Anchor Rod and Base Plate Analysis
4. Foundation Analysis
l ■ GPD GROUP
TNXTOWER ANALYSIS PRINTOUT
o # GPD GROUP
Job Page
tnxTower PO01373B GREENBURG 1 of 6
GPD Group Project Date
520 South Main St. Suite 2531 2012793.58 08:18:27 04/12/12
Akron, OH 44311 Client Designed by
Phone: (330) 572 -2100 T- Mobile Towers
FAX: (220) 572 -2101 ewells
Tower Input Data
There is a pole section.
This tower is designed using the TIA -222 -G standard.
The following design criteria apply:
lower is located in Washington County, Oregon.
Basic wind speed of 95 mph.
Structure Class II.
Exposure Category C.
Topographic Category 1.
Crest Height 0.00 ft.
Nominal ice thickness of 1.0000 in.
Ice thickness is considered to increase with height.
Ice density of 56 pcf.
A wind speed of 30 mph is used in combination with ice.
Temperature drop of 50 °F.
Deflections calculated using a wind speed of 60 mph.
A non - linear (P- delta) analysis was used.
Pressures are calculated at each section.
Stress ratio used in pole design is 1.
Local bending stresses due to climbing loads, feedline supports, and appurtenance mounts are not considered.
Feed Line /Linear Appurtenances - Entered As Round Or Flat
Description Sector Component Placement Total Number Start/End Width or Perimeter Weight
Type Number Per Row Position Diameter
ft in in plf
LDF7 -50A (1 -5/8 FOAM) B Surface Ar 117.00 - 8.00 5 5 0.000 0.0000 0.82
(CaAa) 0.000
LDF7 -50A (1 -5/8 FOAM) B Surface Ar 117.00 - 8.00 1 1 0.000 1.9800 0.82
(CaAa) 0.000
LDF7 -50A (1 -5/8 FOAM) A Surface Ar 90.00 - 8.00 10 10 -0.500 0.0000 0.82
(CaAa) -0.500
LDF7 -50A (1 -5/8 FOAM) A Surface Ar 90.00 - 8.00 2 2 -0.500 1.9800 0.82
(CaAa) -0.500
Feed Line /Linear Appurtenances - Entered As Area
Description Face Allow Component Placement Total CAA Weight
or Shield Type Number
Leg ft f /ft Pr
LDF7 -50A (1 -5/8 C No Inside Pole 127.00 - 8.00 24 No Ice 0.00 0.82
FOAM) 1/2" Ice 0.00 0.82
I" Ice 0.00 0.82
LDF7 -50A (1 -5/8 C No Inside Pole 100.00 - 8.00 1 No Ice 0.00 0.82
FOAM) 1/2" Ice 0.00 0.82
I" Ice 0.00 0.82
CATS Cable A No Inside Pole 107.00 - 8.00 9 No Ice 0.00 0.09
1/2" Ice 0.00 0.09
I" Ice 0.00 0.09
Job °b Page
P0013736 GREENBURG 2 of 6
GPD Group Project Date
520 South Main St. Suite 2531 2012793.58 08:18:27 04/12/12
• Akron, OH 44311 Client Designed by
Phone: (330) 572 -2100 T- Mobile Towers
FAX: (220) 572 -2101 ewells
Discrete Tower Loads
Description Face Offset Offsets: Azimuth Placement C C Weight
or Type Hon Adjustment Front Side
Leg Lateral
Vert
fi ft fr' fr' lb
h
ft
12' LP Platform C None 0.0000 127.00 No Ice 25.00 25.00 1500.00
1/2" Ice 30.00 30.00 1750.00
I" Ice 35.00 35.00 2000.00
(4) TMBXX- 6516 -R2M w/ 6' B From Face 3.50 0.0000 127.00 No Ice 7.08 5.24 56.50
Mount Pipe 0.00 1/2" Ice 7.64 6.12 109.72
0.00 I" Ice 8.18 6.87 173.27
(4) TMBXX- 6516 -R2M w/ 6' A From Face 3.50 0.0000 127.00 No Ice 7.08 5.24 56.50
Mount Pipe 0.00 1/2" Ice 7.64 6.12 109.72
0.00 I" Ice 8.18 6.87 173.27
(4) TMBXX- 6516 -R2M w/ 6' C From Face 3.50 0.0000 127.00 No Ice 7.08 5,24 56.50
Mount Pipe 0.00 1/2" Ice 7.64 6.12 109.72
0.00 I" Ice 8.18 6.87 173.27
(4) ETW 19OVS12UB B From Face 3.50 0.0000 127.00 No Ice 0.66 0.35 11.00
0.00 1/2" Ice 0.78 0.44 15.83
0.00 1" Ice 0.90 0.54 22.17
(4) ETW19OVS12UB A From Face 3.50 0.0000 127.00 No Ice 0.66 0.35 11.00
0.00 1/2" Ice 0.78 0.44 15.83
" 0.00 1" Ice 0.90 0.54 22.17
(4) ETW190VS12UB C From Face 3.50 0.0000 127.00 No Ice 0.66 0.35 11.00
0.00 1/2" Ice 0.78 0.44 15.83
0.00 1" Ice 0.90 0.54 22.17
10' T -Arms (1) A From Face 1.50 0.0000 117.00 No Ice 3.90 2.34 250.00
0.00 1/2" Ice 4.30 2.58 300.00
0.00 1" Ice 4.70 2.82 350.00
10' T -Arms (1) B From Face 1.50 0.0000 117.00 No Ice 3.90 2.34 250.00
0.00 1/2" Ice 4.30 2.58 300.00
0.00 I" Ice 4.70 2.82 350.00
10' T -Arms (1) C From Face 1.50 0.0000 117.00 No Ice 3.90 2.34 250.00
0.00 1/2" Ice 4.30 2.58 300.00
0.00 I" Ice 4.70 2.82 350.00
(2) PCSS065 -19 -2 w/Mount C From Face 3.00 0.0000 117.00 No Ice 6.20 3.31 39.55
Pipe 0.00 1/2" Ice 6.76 4.74 81.15
0.00 I" Ice 7.29 5.89 134.25
(2) PCSS065 -19 -2 w/Mount B From Face 3.00 0.0000 117.00 No Ice 6.20 3.31 39.55
Pipe 0.00 1/2" Ice 6.76 4.74 81.15
0.00 I" Ice 7.29 5.89 134.25
(2) PCSS065 -19 -2 w/Mount A From Face 3.00 0.0000 117.00 No Ice 6.20 3.31 39.55
Pipe 0.00 1/2" Ice 6.76 4.74 81.15
0.00 I" Ice 7.29 5.89 134.25
Valmont 13' Platform w/o C None 0.0000 90.00 No Ice 35.00 35.00 1500.00
Rails 1/2" Ice 42.00 42.00 2500.00
1" Ice 49.00 49.00 3500.00
(2) LPD -4019 w/Mount Pipe C From Face 3.50 0.0000 90.00 No Ice 8.37 12.34 100.85
0.00 1/2" Ice 9.07 13.87 184.00
0.00 1" Ice 9.78 15.42 282.11
(2) BXA- 70063/8 w/ 7' MP C From Face 3.50 0.0000 90.00 No Ice 10.66 7.18 49.55
0.00 1/2" Ice 11.26 8.48 118.59
0.00 I" Ice 11.87 9.49 200.87
(2) LPD -6516 w/Mount Pipe B From Face 3.50 0.0000 90.00 No Ice 12.87 12.56 89.70
0.00 1/2" Ice 13.59 13.99 150.66
0.00 1" Ice 14.32 15.27 222.26
BXA- 185063/12CF w/ mount B From Face 3.50 0.0000 90.00 No Ice 5.00 5.30 40.55
Job °b Page
P001373B GREENBURG 3 of 6
GPD Group Project Date
520 South Main St. Suite 2531 2012793.58 08:18:27 04/12/12
• Akron, OH 44311 Client Designed by
Phone: (330) 572 -2100 T- Mobile Towers
FAX: (220) 572 -2101 ewells
Description Face Offset Offsets: Azimuth Placement C C Weight
or Type Hon Adjustment Front Side
Leg Lateral
Vert
ft ft ill ft2 lb
ft
ft
pipe 0.00 1/2" Ice 5.55 6.47 83.66
0.00 I" Ice 6.07 7.35 138.22
BXA- 70040/8CF w/ Mount B From Face 3.50 0.0000 90.00 No Ice 22.29 10.21 82.85
Pipe 0.00 1/2" Ice 23.18 11.72 210.49
0.00 1" Ice 24.07 13.26 353.97
(2) LPD- 7907/8 w/Mount A From Face 3.50 0.0000 90.00 No Ice 6.00 15.50 84.20
Pipe 0.00 1/2" Ice 6.59 17.04 135.64
0.00 I" Ice 7.17 18.43 197.55
BXA- 185085/12CF w/ Mount A From Face 3.50 0.0000 90.00 No Ice 5.07 5.63 53.53
Pipe 0.00 1/2" Ice 5.60 6.65 100.55
0.00 I" Ice 6.12 7.52 157.39
XP20 -45 w/ Mount Pipe A From Face 3.50 0.0000 90.00 No Ice 6.91 4.83 39.90
0.00 1/2" Ice 7.45 5.75 89.47
0.00 I" Ice 7.99 6.54 149.77
8' 2.5 std pipe A From 1.00 0.0000 107.00 No Ice 2.00 2.00 46.32
Centroid -Le 0.00 1/2" Ice 2.83 2.83 61.29
g 0.00 1" Ice 3.46 3.46 81.56
8' 2.5 std pipe B From 1.00 - 30.0000 107.00 No Ice 2.00 2.00 46.32
Centroid -Le 0.00 1/2" Ice 2.83 2.83 61.29
g 0.00 1" Ice 3.46 3.46 81.56
8' 2.5 std pipe C From 1.00 0.0000 107.00 No Ice 2.00 2.00 46.32
Centroid -Fa 0.00 1/2" Ice 2.83 2.83 61.29
ce 0.00 1" Ice 3.46 3.46 81.56
8' 2.5 std pipe C From 1.00 30.0000 107.00 No Ice 2.00 2.00 46.32
Centroid -Le 0.00 1/2" Ice 2.83 2.83 61.29
g 0.00 I" Ice 3.46 3.46 81.56
840 -10057 A From 1.25 0.0000 109.00 No Ice 2.49 1.33 10.00
Centroid -Le 0.00 1/2" Ice 2.81 1.59 24.19
g 0.00 I" Ice 3.13 1.85 41.87
840 -10057 B From 1.25 - 30.0000 109.00 No Ice 2.49 1.33 10.00
Centroid -Le 0.00 12" Ice 2.81 1.59 24.19
g 0.00 1" Ice 3.13 1.85 41.87
840 -10057 C From 1.25 0.0000 109.00 No Ice 2.49 1.33 10.00
Centroid -Fa 0.00 1/2" Ice 2.81 1.59 24.19
ce 0.00 I" Ice 3.13 1.85 41.87
840 -10057 C From 1.25 30.0000 109.00 No Ice 2.49 1.33 10.00
Centroid -Le 0.00 1/2" Ice 2.81 1.59 24.19
g 0.00 I" Ice 3.13 1.85 41.87
BTS -2500 A From 1.25 0.0000 109.00 No Ice 2.12 0.96 35.00
Centroid -Le 0.00 12" Ice 2.32 1.12 48.31
g 0.00 l" Ice 2.53 1.29 64.14
BTS -2500 B From 1.25 - 30.0000 109.00 No Ice 2.12 0.96 35.00
Centroid -Le 0.00 1 /2" Ice 2.32 1.12 48.31
g 0.00 1" Ice 2.53 1.29 64.14
BTS -2500 C From 1.25 0.0000 109.00 No Ice 2.12 0.96 35.00
Centroid -Fa 0.00 1/2" Ice 2.32 1.12 48.31
ce 0.00 1" Ice 2.53 1.29 64.14
BTS -2500 C From 1.25 30.0000 109.00 No Ice 2.12 0.96 35.00
Centroid -Le 0.00 1/2" Ice 2.32 1.12 48.31
g 0.00 1" Ice 2.53 1.29 64.14
Generic GPS C From Leg 0.25 0.0000 107.00 No Ice 0.21 0.21 15.00
0.00 1/2" Ice 0.32 0.32 17.52
0.00 1" Ice 0.44 0.44 21.31
Job o ti Page
P001373B GREENBURG 4 of 6
GPD Group Project Date
520 South Main St. Suite 2531 2012793.58 08:18:27 04/12/12
Akron, OH 44311 Client Designed by
Phone: (330) 572 -2100 T- Mobile Towers
FAX: (220) 572 -2101 ewells
Dishes
Description Face Dish Offset Offsets: Azimuth 3 dB Elevation Outside Aperture Weight
or Type Type Horz Adjustment Beam Diameter Area
Leg Lateral Width
Vert
ft ft ft fr lb
4 FT DISH C Paraboloid w/o From 0.00 0.0000 100.00 4.00 No Ice 12.56 170.00
Radome Face 0.00 1/2" Ice 13.09 237.19
0.00 1" Ice 13.62 304.38
HPD2 -23 A Paraboloid From 1.25 0.0000 105.00 2.00 No Ice 3.14 30.00
w /Shroud (HP) Centroid 0.00 1/2" Ice 3.41 70.00
-Leg 0.00 1" Ice 3.68 100.00
HPD2 -23 B Paraboloid From 1.25 - 30.0000 105.00 2.00 No Ice 3.14 30.00
w /Shroud (HP) Centroid 0.00 1/2" Ice 3.41 70.00
-Leg 0.00 1" Ice 3.68 100.00
HPD2 -23 C Paraboloid From 1.25 0.0000 105.00 2.00 No Ice 3.14 30.00
w /Shroud (HP) Centroid 0.00 1 /2" Ice 3.41 70.00
-Face 0.00 1" Ice 3.68 100.00
HPD2 -23 C Paraboloid From 1.25 30.0000 105.00 2.00 No Ice 3.14 30.00
w /Shroud (HP) Centroid 0.00 1/2" Ice 3.41 70.00
-Leg 0.00 I" Ice 3.68 100.00
Maximum Tower Deflections - Service Wind
Section Elevation Horz. Gov. Tilt Twist
No. Deflection Load
ft in Comb. °
LI 130 - 80.917 29.105 40 1.9554 0.0032
L2 85 - 45.083 12.424 40 1.4184 0.0015
L3 50 - 0 4.185 40 0.7848 0.0005
Critical Deflections and Radius of Curvature - Service Wind
Elevation Appurtenance Gov. Deflection Tilt Twist Radius of
Load Curvature
ft Comb. in ft
127.00 12' LP Platform 40 27.902 1.9255 0.0030 26470
117.00 10' T -Arms (1) 40 23.921 1.8237 0.0027 10180
109.00 840- 10057 40 20.817 1.7371 0.0023 6302
107.00 8' 2.5 std pipe 40 20.059 1.7143 0.0023 5753
105.00 HPD2 -23 40 19.308 1.6910 0.0022 5293
100.00 4 FT DISH 40 17.474 1.6302 0.0020 4410
90.00 Valmont 13' Platform w/o Rails 40 14.020 1.4946 0.0016 3307
Maximum Tower Deflections - Design Wind
Section Elevation Horz. Gov. Tilt Twist
No. Deflection Load
ft in Comb. °
L 130 - 80.917 130.901 4 8.8294 0.0133
L2 85 - 45.083 55.982 4 6.4039 0.0062
L3 50 - 0 18.876 4 3.5423 0.0023
Job °b Page
P0013736 GREEN BURG 5 of 6
GPD Group Project Date
520 South Main St. Suite 2531 2012793.58 08:18:27 04/12/12
` Akron, OH 44311 Client Designed by
Phone: (330) 572 -2100 T - Mobile Towers
FAX: (220) 572 -2101 ewe! is
Critical Deflections and Radius of Curvature - Design Wind I
Elevation Appurtenance Gov. Deflection Tilt Twist Radius of
Load Curvature
ft Comb. in it
127.00 12' LP Platform 4 125.498 8.6942 0.0166 6091
117.00 10' T -Arms (1) 4 107.629 8.2344 0.0139 2340
109.00 840 -10057 4 93.694 7.8432 0.0117 1446
107.00 8' 2.5 std pipe 4 90.287 7.7404 0.0112 1319
105.00 HPD2 -23 4 86.917 7.6352 0.0107 1213
100.00 4 FT DISH 4 78.677 7.3602 0.0095 1009
90.00 Valmont 13' Platform w%o Rails 4 63.159 6.7479 0.0073 753
Compression Checks
Pole Design Data I
Section Elevation Size I. L. KUr A P. gyp, Ratio
No. P.
ft ft ft in lb lb *P.
Ll 130 - 80.917 TP25.074x14.763x0.2188 49.08 0.00 0.0 16.9033 - 9248.11 1145230.00 0.008
(1)
L2 80.917 - TP32.16x23.7788x0.3125 39.92 0.00 0.0 31.0077 - 15636.10 2191330.00 0.007
45.083 (2)
L3 45.083 -0 (3) TP41x30.5026x0.375 50.00 0.00 0.0 49.0547 - 28207.50 3341220.00 0.008
Pole Bending Design Data I
Section Elevation Size Xi OM„, Ratio M, dM, Ratio
No. M., M r
ft lb -ft lb-ft 77:0 lb-ft lb-ft 4,M
LI 130 - 80.917 TP25.074x 14.763x02188 429149.17 559231.67 0.767 0.00 559231.67 0.000
(
L2 80.917 - TP32.16x23.7788x0.3125 1181425.00 1372666.67 0.861 0.00 1372666.67 0.000
45.083 (2)
L3 45.083 - 0 (3) TP4I x30.5026x0.375 2466033.33 2761741.67 0.893 0.00 2761741.67 0.000
Pole Shear Design Data
Section Elevation Size Actual $Y Ratio Actual $T Ratio
No. V V T. T
ft lb lb •y, lb-ft lb-ft 4)T
Ll 130 - 80.917 TP25.074x14.763x0.2188 19705.40 572614.00 0.034 28.50 1133950.00 0.000
(1)
L2 80.917- TP32.16x23.7788x0.3125 23281.90 1095660.00 0.021 28.56 2783333.33 0.000
45.083 (2)
L3 45.083 - 0 (3) TP41 x30.5026x0.375 27888.40 1670610.00 0.017 28.51 5599950.00 0.000
tnxTower Job Page
P001373B GREENBURG 6 of 6
GPD Group Project Date
520 South Main St. Suite 2531 2012793.58 08:18:27 04/12/12
- Akron, OH 44311 Client Designed by
Phone: (330) 572 -2100 T- Mobile Towers
FAX: (220) 572 -2101 ewells
Pole Interaction Design Data
Section Elevation Ratio Ratio Ratio Ratio Ratio Comb. Allow. Criteria
No. P„ H,, Ad, V. T Stress Stress
ft $P,, (pM +Mm +y •T Ratio Ratio
LI 130 - 80.917 0.008 0.767 0.000 0.034 0.000 0.777 1.000
4.8/ ✓
(I) ✓
L2 80.917 - 0.007 0.861 0.000 0.021 0.000 0.868 1.000 482 ✓
45.083 (2) ✓
L3 45.083 - 0 (3) 0.008 0.893 0.000 0.017 0.000 0.902 1.000 4.8.2 4
V
Section Capacity Table I
Section Elevation Component Size Critical P ®P % Pass
No. ,Jt Type Element lb lb Capacity Fail
LI 130 - 80.917 Pole TP25.074x14.763x0.2188 1 - 9248.11 1145230.00 77.7 Pass
L2 80.917 - 45.083 Pole TP32.16x23.7788x0.3125 2 - 15636.10 2191330.00 86.8 Pass
L3 45.083 - 0 Pole TP41x30.5026x0.375 3 - 28207.50 3341220.00 90.2 Pass
Summary
Pole (L3) 90.2 Pass
RATING — 90.2 Pass
Program Version 6.0.4.0 - 1/27/2012 File:C:/ Users /ewells/ Desktop /tnxTower58 /greenburg.eri
TOWER ELEVATION DRAWING AND FEEDLINE PLAN
0 %0 GPD GROUP
•
130.011
tit I DESIGNED APPURTENANCE LOADING
I, { TYPE ELEVATION TYPE ELEVATION
17 LP Platform 127 .978.2500 109
(4) TMBXX - 6516 -R2M w/ 6' Mont 127 BTS -2500 106
• Pi 6' 2.5 me Pipe 107
(4) TMBXX- 6516 -R2M w/ 6' Moot 127 8' 2.5 sic pipe 107
Pipe 8' 2.5 std pipe 107 4 ,� (4) TMBXX- 6516 -R2M w/ 8' Mont 127 8' 2.5 std pipe 107
• I ( 4 E 1W190VS12U8 127 - Generic GPS 107
�j g (4) ETw190VS12Ue 127 11002 -23 105
S $ S I- o (4)ETW1WV312U8 121 HPD2 -23 105
w n 10'T- Arme 117 HPD2 -23 106
1p7 -Acme (1) 117 -23 - - - - -- 106
1VT - -Arms (1) _ - - -- 117 FTDISH 100
(2) PCSS05 - 19-2 wAbuM Pips 117 - 'B
XA- 70040 /6CF w/ Mount Pipe SO
(2) PCS .SD66-16.2 •M19pul Plpe 117 (2)LPD- 790718 wMOrM Pipe 90
(2) PC65065.19.2 dhow! Pipe 117 BXA- 185085/12CF w/ Moot Plpe 60
84P 70057 109 - I XP20-45 w/ Mont Pipe 90
6810057 109 BXA-185063/12CF w / Mont pipe 90
840.10067 109
Valmont 1 3' 9 w/M u t Pipe 90
.10067 109 LPD -4019 w/Moxt Pips 90
640
BTS2600 100 _ Q (4 ) 8XM7 0063l8 w/ 7 MP 90
(2) LPD -8516 w /Mount Pips 90
/ 4.1C111:111.1.
eose I MATERIAL STRENGTH
' I GRADE I Fy I Fu GRADE I FY i Fu I
A572 -85 y 65 kW 80 MI
TOWER DESIGN NOTES
1. Tower is located in Washington County, Oregon.
2. Tower designed for Exposure C to the TIA -222 -G Standard.
3. Tower designed for a 95 mph basic wind in accordance with the TIA -222 -G Standard.
S g V 4. Tower is also designed for a 30 mph basic wind with 1.00 in ice. Ice is considered to
t; H I ' f $ a; 8 increase in thickness with height.
o R R 44 5. Deflections are based upon a 80 mph wind.
I 6. Tower Structure Class II.
7. Topographic Category 1 with Crest Height of 0.0011
8. TOWER RATING: 90.2%
I ff
I .
45.11/
w it
ALL REACTIONS
ARE FACTORED
1 AXIAL
A • p 61468 lb
� q 6
R
SHEAR MOMENT
29151b ( J I 279029 lb-ft
TORQUE 103 lb -ft
30 mph WIND - 1.0000 in ICE
AXIAL
28247 lb
/--'
SHEAR / MOMENT
2784816 2466030 !b -ft
•
0.011
TORQUE 892 lb-ft
R EACTIONS - 95 mph WIND
i
I1 1,1 i
A GPD Group IoD: P001373B GREENBURG
/A& 520 South Main St. Suite 2531 P1 dJe d 2012793.58
(; -5) I,Fl4 Akron, OH 44311 c1 ie M T- Mobile Towers Dr "'' n ° t'ewella ^ * Ak _
GOD Group Phone: (330) 572 -2100 code. TIA -222 -G L 04112/12 SG"' NTS
FAX: (220) 572 - 2101 Pei C:Wwclww aDawooam.TOwar67nrswdw.M C.*9 NO. E -
1 -5/8" Coax for (Cricket)
0
CATS Cables for (Clearwire) —��
0
0
0
• •
•
°cogo • •
1-5/8" Coax for (Verizon)
N— 1 -5/8" Coax for (T- Mobile)
COAX PLACEMENT
NOT TO SCALE -1
•
% JOB P001373B GREENBURG 2012793.58
GPD GROUP. DATE
gra P." Ll1,nw, Bum ems, ax. 4/12/12
520 South Main Street, Suite 2531
BY
Akron, Ohio 44311 DRAWN
330-572.2100 Fax 330-572-2101 EJW J
ANCHOR ROD AND BASE PLATE ANALYSIS
I
%:a GPD GROUP
Anchor Rod and Base Plate Stresses, TIA- 222 -G -1
/'.■ PO01373B GREENBURG
• 2012793.58
GPD GROUP
Overturning Moment = 2466.03 k'ft
•
Axial Force = 28.25 k I Acceptable Stress)
Shear Force = 27.85 k Ratio = 105.0 %I
Anchor Rods Base Plate
(Section 4.9.9, T1A 222 - G - 1) Location = External
Number of Rods = 12 Plate Strength (Fy) = 60 ksi
$ = 0.8 = 0.9
Rod Ultimate Strength (F„) = 100 ksi Outside Diameter = 54.95 in
Base Plate Detail Type` = d Plate Thickness = 2.75 in
Rod Circle = 48.95 in wcalc = 26.74 in
Rod Diameter = 2.25 in wmax = 40.17 in
Net Tensile Area = 3.25 in` w = 26.74 in
Max Tension on Rod = 198.95 kips Z = 50.56 in
Max Compression on Rod = 203.66 kips M, = 1236.29 k -in
P„ = 203.66 kips tpM = 2730.13 k -in
V, = 2.32 kips BP Capacity = 45.3% OK
n = 0.50
tPRnr = 260.00 kips Pole
Anchor Rod Capacity = 80.1% OK Pole Diameter = 41 in
Number of Sides = 12,
*This analysis assumes the clear distance Thickness = 0.375 in
from the top of the concrete to the bottom of Pole Yield Strength = 65 ksi
the leveling nut is less than the diameter of
the anchor rod. Notify GPD Group
immediately if existing field conditions do
not meet this assumntinn
Stiffeners
Configuration =] None]
GPD Round Base Plate Stress (Rev G) - V1.07a
FOUNDATION ANALYSIS
.■ GPD GROUP
•
CAISSON ANALYSIS WORKSHEET
Client: T- Mobile Towers Job No.: 2012793.58
�'._ Site ID: PO01373B Sheet No: 1 Of 1
Site Name: GREENBURG Made By: EJW Date: 4/12/2012
GPD GROUP Location: Washington County, OR Chk'd By: CJS Date: 4/12/2012
Loading Type: Wind Code: G
FOUNDATION DATA RISA Reactions
Diameter = 5.5 ft Moment = 2466.03 ft-k
Length = 28 ft Axial = 28.247 kips
Rebar Size = #10 Shear = 27.848 kips
#of bars= 20
Tie Size = #4
Clear Cover = 3 inches
Edge to Bar Center = 4.135 inches
fc = 4 ksi
LPILE TYPE 2 ANALYSIS FOR REINFORCING CAPACITY
Mn = 42559.39 in -k
Mn = 3546.62 ft-k
Load Factor = 1
(flexure) = 0.9
iMn = 3191.95 ft -k
MOMENT FROM CAISSON PROGRAM USING ADJUSTED S.F. AND ACTUAL CAISSON LENGTH
Moment = 2620.3 ft -k (max. moment along caisson)
REINFORCING STEEL CAPACITY
LF'Moment from Caisson 2620.30 ft -k
Capacity = _ = 82.1% O.K.
fMn 3191.95 ft-k
SOIL CAPACITY FROM CAISSON PROGRAM USING ADDITIONAL SAFETY FACTORS
ADDITIONAL SAFETY FACTOR FROM CAISSON = 1.52
Phi (Soil) = 0.75
1 /phi(soil) 1.33
Capacity = _ = 87.7% O.K.
Additional Safety Factor 1.52
' ' . , • •
CAISSON Version 4.46 Thu Apr 12 08:26:18 2012
U.W. Short Course - 1998
********************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
* *
* PIER FOUNDATIONS ANALYSIS AND DESIGN - (C) 1995, POWER LINE SYSTEMS, INC.*
* *
********************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
* ** ANALYSIS IDENTIFICATION : PO01373B GREENBURG
NOTES : 2012793.58
* ** PIER PROPERTIES CONCRETE STRENGTH (ksi) = 3.40 STEEL STRENGTH (ksi) = 60.00
DIAMETER (ft) = 5.500 DISTANCE FROM TOP OF PIER TO GROUND LEVEL (ft) = 1.00
* ** SOIL PROPERTIES LAYER TYPE THICKNESS DEPTH AT TOP OF LAYER DENSITY CU KP PHI
(ft) (ft) (pcf) (psf) (degrees)
1 C 3.00 0.00 115.0 0.0
2 S 9.00 3.00 115.0 3.000 30.00
3 C 25.00 12.00 120.0 600.0
* ** DESIGN (FACTORED) LOADS AT TOP OF PIER MOMENT (ft -k) = 2466.0 VERTICAL (k) = 28.2 SHEAR (k) = 27.8
ADDITIONAL SAFETY FACTOR AGAINST SOIL FAILURE = 1.52
* ** CALCULATED PIER LENGTH (ft) = 28.000
* ** CHECK OF SOILS PROPERTIES AND ULTIMATE RESISTING FORCES ALONG PIER
TYPE TOP OF LAYER BELOW TOP OF PIER THICKNESS DENSITY CU KP FORCE ARM
(ft) (ft) (pcf) (psf) (k) (ft)
C 1.00 3.00 115.0 0.0 0.00 2.50
S 4.00 9.00 115.0 3.000 384.24 9.40
C 13.00 1.03 120.0 600.0 27.27 13.52
C 14.03 13.97 120.0 600.0 - 368.73 21.02
* ** SHEAR AND MOMENTS ALONG PIER
WITH THE ADDITIONAL SAFETY FACTOR WITHOUT ADDITIONAL SAFETY FACTOR
DISTANCE BELOW TOP OF PIER (ft) SHEAR (k) MOMENT (ft -k) SHEAR (k) MOMENT (ft -k)
0.00 42.8 3769.0 28.1 2479.6
2.80 42.8 3888.8 28.1 2558.4
5.60 8.2 3982.8 5.4 2620.3
8.40 -87.5 3882.2 -57.5 2554.1
11.20 -227.7 3451.3 -149.8 2270.6
14.00 -367.9 2587.2 -242.0 1702.1
16.80 -295.7 1655.8 -194.5 1089.3
19.60 -221.8 931.4 -145.9 612.8
22.40 -147.8 414.0 -97.3 272.3
25.20 -73.9 103.5 -48.6 68.1
28.00 0.0 0.0 0.0 0.0
U.W. Short Course - 1998 Page 1/2
• ' t
* ** TOTAL REINFORCEMENT PCT = 0.68 REINFORCEMENT AREA (in ^2) = 23.26
* ** USABLE AXIAL CAP. (k) = 28.2 USABLE MOMENT CAP. (ft -k) = 2678.8
* ** US Standard Re -Bars (Select one of the following):
117 BARS #4 (AREA = 0.20 in ^2 DIA = 0.500 in) AT SPACING (in) = 1.50
76 BARS #5 (AREA = 0.31 in ^2 DIA = 0.625 in) AT SPACING (in) = 2.31
53 BARS #6 (AREA = 0.44 in ^2 DIA = 0.750 in) AT SPACING (in) = 3.32
39 BARS #7 (AREA = 0.60 in ^2 DIA = 0.875 in) AT SPACING (in) = 4.51
30 BARS #8 (AREA = 0.79 in ^2 DIA = 1.000 in) AT SPACING (in) = 5.86
24 BARS #9 (AREA = 1.00 in ^2 DIA = 1.128 in) AT SPACING (in) = 7.33
19 BARS #10 (AREA = 1.27 in ^2 DIA = 1.270 in) AT SPACING (in) = 9.26
15 BARS #11 (AREA = 1.56 in ^2 DIA = 1.410 in) AT SPACING (in) = 11.73
11 BARS #14 (AREA = 2.25 in ^2 DIA = 1.693 in) AT SPACING (in) = 15.99
* ** PRESSURE UNDER CAISSON DUE TO DESIGN AXIAL LOAD (psf) = 1188.9
U.W. Short Course - 1998 Page 2/2
P001373B.lpo
LPILE Plus for windows, version 5.0 (5.0.39)
Analysis of Individual Piles and Drilled Shafts
subjected to Lateral Loading using the p -y Method
(c) 1985 -2007 by Ensoft, Inc.
All Rights Reserved
This program is licensed to:
ewells
GPD Group
Path to file locations: C: \Documents and Settings \ewells \Desktop\
Name of input data file: P001373B.1pd
Name of output file: P001373B.lpo
Name of plot output file: P001373B.lpp
Name of runtime file: P001373B.1pr
Time and Date of Analysis
Date: April 11, 2012 Time: 16:14:32
Problem Title
• P001373B GREENBURG
Program Options
units used in Computations - US customary Units: Inches, Pounds
Basic Program Options:
Analysis Type 2:
- Computation of Ultimate Bending Moment of Cross Section (Section Design)
Computations of Nominal Moment Capacity and Nonlinear Bending stiffness
Number of sections = 1
Pile section No. 1
The sectional shape is a circular drilled shaft (bored pile).
Page 1
• P001373B.lpo
Outside Diameter = 66.0000 in
Material Properties:
Compressive Strength of Concrete = 4.000 kip /in * *2
Yield Stress of Reinforcement = 60. kip /in * *2
Modulus of Elasticity of Reinforcement = 29000. kip /in * *2
Number of Reinforcing Bars = 20
Area of Single Bar = 1.27000 in * *2
Number of Rows of Reinforcing Bars = 11
Area of Steel = 25.400 in * *2
Area of shaft = 3421.194 in * *2
Percentage of steel Reinforcement = .742 percent
Cover Thickness (edge to bar center) = 4.135 in
unfactored Axial Squash Load Capacity = 13069.70 kip
Distribution and Area of steel Reinforcement
Row Area of Distance to
Number Reinforcement Centroidal Axis
in * *2 in
1 1.270 28.865
2 2.540 27.452
3 2.540 23.352
4 2.540 16.966
5 2.540 8.920
6 2.540 0.000
7 2.540 -8.920
8 2.540 - 16.966
. 9 2.540 - 23.352
10 2.540 - 27.452
11 1.270 - 28.865
Axial Thrust Force = 28000.00 lbs
unfactored (Nominal) Moment Capacity at Concrete Strain of 0.003 = 42559.39108
in -kip
The analysis ended normally.
Page 2
. ?() P2cl 2_-aa a73
PROJECT TEAM:
SITE INFORMATION: PROJECT DESCRIPTION:
NAME: POR DARTMOUTH VERBAL SUMMARY: WITHOUT FORCE OR EFFECT ON THE APPLICANT:
ADDRESS: 11744 PACIFIC HIGHWAY CONTRACT DOCUMENTS THE DESCRIPTION OF THE PROPOSED VERIZON WIRELESS (VAW) LLC d /b /a VERIZON WIRELESS
TIGARD, OREGON 97223 WORK CAN BE DESCRIBED AS FOLLOWS: PRT NE 122nd AVE ver�Zonw�rei�SS
PORTLAND, OREGON 97230
TAX ID: R284105 AT THIS EXISTING COMMUNICATIONS FACILITY VERIZON
--)
7. OCCUPANCY TYPE: S2
WIRELESS PROPOSES THE FOLLOWING MODIFICATION: SIX (6)
APPLICANT'S REPRESENTATIVE: ; POR
PANEL ANTENNAS WILL BE REMOVED AND SIX (6) SIMILAR 1 i
CONSTRUCTION TYPE: VN 7y'
PANEL ANTENNAS WILL BE INSTALLED LEAVING A TOTAL OF URBAN WIRELESS, LLC :. It ns R `" °"
- CURRENT ZONING: WR TWELVE (12) PANEL ANTENNAS. TWO (2) DIPLEXERS WILL 10376 SE SUNBURST WAY
BE ADDED TO EACH OF THREE (3) SECTORS. AN PORTLAND, OREGON 97086 t
•
COORDINATES PER SMR: EQUIPMENT CABINET WILL BE ADDED AT GROUND LEVEL ON CONTACT: SHANIN PRUSIA t1 1
AN EXISTING CONCRETE PAD. THERE WILL BE NO CHANGE
PHONE: 503.720.7295 2 ' DARTMOUTH
TO THE OVERALL STRUCTURE HEIGHT.
LATITUDE: 045' 26' 03.17 N
LONGI TUDE: 122' 45' 31.13 W verizen ' lre ." CONSTRUCTION MANAGER: . 11744 PACIFIC HIGHWAY
GROUND ELEVATION: 199' AMSL w ess
CODE COMPLIANCE: VERIZON WIRELESS
5430 NE 122nd AVE TIGARD, OREGON 97223
INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS PORTLAND, OREGON 97230 Urban Wireless, LLC A
ALL WORK AND MATERIALS SHALL BE PERFORMED AND CONTACT: JOE AHSING
OF THE FOLLOWING CODES AS ADOPTED BE THE LOCAL LESSOR: 10)76 Sunburst Way
GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO
BE CONSTRUED TO PERMIT WORK NOT IN COMPLIANCE 23 MOBILE Portland, Oregon 97086 CO x x
CONCORD, WITH THESE CODES. , LANE, CA 94520 0 STE 2 A Sbanin Prusia
1. 2010 OREGON STRUCTURAL SPECIALTY CODE E T: oVW TARDIFF Pr
o .72 .7295 Cr •
2. 2010 OREGON MECHANICAL SPECIALTY CODE 505
/11( x x
3. 2008 EDITION OREGON PLUMBING SPECIALTY CODE ARCHITECT:
4. 2008 EDITION OREGON ELECTRICAL SPECIALTY CODE POR
DOUGLAS COTTEL ARCHITECT
1332 LAWRENCE STREET, STE 1
EUGENE, OREGON 97401
CONTACT DOUG COTTEL
PHONE: 541.686.9796
SURVEYOR:
HAVER ROSS & SPORSEEN \ '
15 SE 82n DR
DARTMOUTH GLADSTONEaOR 97027
PHONE: 503.657.1384 WI RELE S S
POWER COMPANY: PGE 11744 PACIFIC HIGHWAY SEE SHEET E01 FOR TELECOMMUNICATIONS SITE DEVELOPMENT
CONTACT INFORMATION
cr _ v cm Loc St z Ma p P o i n Y TIGARD, OREGON 97223 TELCO COMPANY: DOUGLAS COTTEL ARCHITECT
°' a 7 1332 LAWRENCE, STE 1, EUGENE OREGON 97401
, 1 41' A n SW Mapleleaf St 5 E E01 FOR PHONE 541 686 9796 douglascottelOcomcast.net
G p a
m m 7 a ' u L CONTACT INFORMATION
JW Oak St " _ a' i i 294
Crec'rlburg SW Pine St v, i 1 f 9 A8 AI��,
z �
S SW Spruce St ^ SW Spruce St "' a
IP ► L• S OTTEL'C"
&.' w Am 1 �.
a
/� �,
. a4 �Gi co V
SW North Dakota St >., ao 11744 SW Pacific Hwy, 294 - APPROVALS t il EU ENE sREGON,.
6 SW Pfaffle St Portland, j' � 312 �O
4 OR 97223 -8462 r ?'�
D 4k 7 ,
a
s LESSOR
Y � 217 R REV DATE ISSUED AS BY
9a 991" BY DATE INDEX TO DRAWINGS
r` 'Dartmouth St — 0 12APR12 BP SUBMITTAL DC
�Q A01 PROJECT INFORMATION •
T 9 g 2 93 A02 OVERALL SITE PLAN
' 6 A03 EQUIPMENT YARD PLAN
Sk g 7 7 7 a ' ° PI A04 ANTENNA INFORMATION AN
a a
N �� r�� , VERIZON WIRELESS APPROVALS SITE ELEVATION
A �: � " a ,, A t - DEPT BY DATE
292. Le. N
■
i
X2006 MicesoCColp x'2005 N4V1EQ,ud /orGD1,lnc ma y. o SWe9 a RE DRAWING FILE
URBAN \35DARTMOUTH
\VZWDARTMOUTHLTE –A01
DRIVING DIRECTIONS FROM PORTLAND MSC: PM SHEET TITLE
PROJECT
Head SW from NE 122nd Avenue. Turn right at NE Shaver Street. Turn left at NE 102nd Avenue. Bear right INFORMATION
onto the I -84W entry romp to Portland and travel approximately 6 miles. Take the 1 -5 south ramp to
Salem /Beaverton and travel approximately 8 miles. Take the OR - 99W exit, exit 294, to Tigard /Newberg. Bear
right of SW Pacific Highway and travel approximately 1 mile. Site is on the left. Access road is just past SW RF 5HLL1 NUMBER
Dartmouth Street. Follow road down the hill to the site.
,/
220 / verI nwireiess
, Z°—
• , Jy/
g� f ' POR
`�� �� DARTMOUTH
`P ---k - " / /I / 11744 PACIFIC HIGHWAY
OA I( TIGARD, OREGON 97223
GAG -- ,- I Urban Wireless, LLC. A
C j �` / I 10376 Sunburst Way
Portland Oregon 97086 y y
/ \ Shanin Prubia /� /a
I I
I I Project Manager 4 •
..- 1
\ � I POWER TO COSTCO 505.720.7295 X X
1� GAS TO COSTCO
F i I Y
s�
.;, _ \\ _
/ c ° � I ( .
/ 6 I / • I POWER TO THE SITE I WIP%ELE S S
-- - L / I TELECOMMUNICATIONS SITE DEVELOPMENT
I
/ TELCO TO THE SITE ARCHITECT
/ I DOUGLAS =TEL
7/ 1332 LAWRENCE. STE 1. EUGENE OREGON 97401
\ ! / PHONE 541 686 9796 douglascottetOcomcast.net
21° ��O Ap
,.' II I �r
• ��\ � 14�1iL ' S OTTEL t'''' a
\ 4 1 " 1 ( .
N I th EU ENE OREGON ,�
, l 1 312 312 S
,�\ I 1 0 in 1> ��CS
'0\ (N • 0
\ II I by REV DATE ISSUED AS BY
�V
_ I 0 12APR12 9P SUBMITTAL DC
S 89' 51 ' 46" E 72.71 '
s _ _ La
° ' �_:: I —
\ �I
�, , I o
LOCATION OF EXISTING COMMUNICATIONS `� / =sr 9
FACILITY WHERE VERIZON WIRELESS S o ,- �
. ',
PROPOSES TO MAKE AN ANTENNA 7 '
._
MODIFICATION AND ADD AN EQUIPMENT 6 41 N. " =� " + O o
CABINET ON AN EXISTING CONCRETE SLAB G� rn ,,111,/ DRAWING FILE
✓ 9\ I +- NORTH URBANMOUTHLTE"A02
\VZWDARTMOUTHLTE —A02
• 7S \ } o (/ SHEET TITLE
\ to 1 OVERALL SITE PLAN OVERALL SITE PLAN
• SHEET NUMBER
A02 1" = 30' -0" A02
\ N_____----
I
\ I I V erI hwir 1
L e ess
\ I POR
. \ 11
I DARTMOUTH
11744 PACIFIC HIGHWAY
\ I I TIGARD, OREGON 97223
1 Urban Wireless, LLC A
SECURITY
EXISTING ROADWAY 10376 Sunburst Watt
FENCING /
Portland, Oregon 97086 /,
ACCESS GATES I Shanin Prusta
,,,„, - --N, , '
Project Manager -4 •
S 89'51'46 "E 72.71' tt • i , 5 O 7lOT.95
x x x�- ---- -x I�
...7...___-------- 4- BOLLARD V.
•
N POWER 7,-..„
I. , ' �p\ \,
METER ,�
(E) LCW WIRELESS VERIZON (E) LCW WIRELESS LEASE AREA AND ��
*A WI ELE SS
COMM H -FRAME EQUIPMENT CABINETS 1
EXISTING SECURITY FENCING N' EMERGENCY TELECOMMUNICATIONS SITE DEVELOPMENT
GENERATOR (E) FENCING
(E) LEASE BOUNDARY DOUGLAS COTTEL ARCHITECT
PROPOSED VERIZON WIRELESS N. \ � -
UTILITY H — FRAME + \ '- N 0 0 0 . 1332 LAWRENCE, STE 1, EUGENE OREGON 97401
D PHONE 541 686 9796 dougloscottelOcomcast.net
r EXISTING VERIZON WIRELESS + R
EQUIPMENT CABINETS ON 6' X / /�° D e " I -0.1D ARc,
20' CONCRETE SLAB + o 'N, %'
v
PROPOSED EQUIPMENT CABINET \ / ' i� x I
ON EXISTING STEEL PLINTH ON i� , J _ I` / L • S OTTEL
EXISTING CONCRETE SLAB \\ , 1 ^ ` �.
la
S • - - _ _ o th EU ENE IREGON,,.. •
EXISTING VERIZON WIRELESS S X X x X x 312'
COAX BRIDGE O •Js D a
9 Cs
9 R
• i I o REV DATE ISSUED AS BY
(E) T- MOBILE p
EQUIPMENT CABINETS
N C 0 12APR12 BP SUBMITTAL DC
(E) STEEL MONOPOLE - --
VERIZON WIRELESS O
ANTENNAS AND d-
FRAMES AT 90' AGL 10
-- I
N
N j
P i f
41111,4 DRAWING FILE
NORTH URBAN \35DARTMOUTH
\VZWDARTMOUTHLTE -A03
( I SHEET TITLE
1 EQUIPMENT YARD PLAN EQUIPMENT YARD
A03 1" = 10' -o" PLAN
SHEET NUMBER
A03
Current panel antenna configuration
\i•
# coax # of TIP OF (E) T- MOBILE ANTENNAS Ver1,� wireless
Freq Band Sector Azimuth Tip Ht Ft runs antennas / 132-6 AGL
Cellular D1 80 94 2 2 I �i
TOP OF (E) MONO POR
• PCS D1 80 93 2 2 111-11-1- �_; —� 11 130 AGL
• 7 00 MHz DARTMOUTH
Cellular D2 160 94 2 2
PCS D2 160 93 2 2 t 1174 PACIFIC HIGHWAY
700 MHz (,1 RAD CENTER OF (E) LCW WIRELESS AilENISAL. TIGARD, OREGON 97223
Cellular D3 325 94 2 2 117' AGL
PCS D3 325 93 2 2 • 1 VARIOUS DISH ANTENNAS Urban Wireless, LLC A,
10376 Sunburst Way
700 MHz Portland, Oregon 97086 x x
Skanin Prusia
Proposed panel antenna configuration Pro ct Manager •
EXISTING AND PROPOSED 5057z07295 x x
VERIZON WIRELESS PANEL ANTENNAS
# coax # of / TIPS AT 93' AND 94' AGE
Freq Band Sector Azimuth Tip Ht Ft runs antennas
EXISTING AND PROPOSED
Cellular D1 80 94 2 2 VERIZON WIRELESS PANEL ANTENNAS
PCS D1 80 93 4xDPLX 1 C/L 90' AGL
7\
700 MHz D1 80 94 2 1
-\ EXISTING AND PROPOSED VERIZON
Cellular D2 160 94 2 2 WIRELESS ANTENNA ARRAY -THREE 40 e WIR ELE S S
PCS D2 160 93 4xDPLX 1 SECTORS - FOUR (4) ANTENNAS PER SECTOR - TWELVE (12) MU
700 MHz D2 160 94 2 1 ANTENNAS TOTAL TELECOMMUNICATIONS SITE DEVELOPMENT
Cellular D3 325 94 2 2 DOUGLAS COTTEL ARCHITECT
PCS D3 325 93 4xDPLX 1
700 MHz D3 325 94 2 1 (E) 130' TALL MONOPOLE 1332 LAWRENCE, STE 1, EUGENE OREGON 97401
PHONE 541 686 9796 dougloscottelOcomcost.net
r
-g$D Aj VA erlie L W L, S OTTEL SECURITY FENCING AND t:4 �
GATES
tI) a EU ENE 1REGON,.
VERIZON WIRELESS ✓ 312 �0
° EQUIPMENT CABINETS AND
EXISTING AND PROPOSED / RE -USE EXISTING GPS ANTENNA
GAMMA (D3) SECTOR PIPE MOUNTS ON , 0��
325' AZIMUTH ° EXISTING FRAMES
FOR ANTENNA
REPLACEMENTS
° REV DATE ISSUED AS BY
OTHER CARRIER
o EQUIPMENT CABINETS 0 12APR12 BP SUBMITTAL DC
EXISTING AND PROPOSED u, z
° ALPHA (D1) SECTOR J
EXISTING STEEL c0°.°16°..'\ 080 AZIMUTH
MONOPOLE W I
o (E) VERIZON COMM o
o a UTILITY H -FRAME a
o *' \ 0 ° 3
is
"
EXISTING AND PROPOSED 1 B _ a z t
BETA (D2) SECTOR J _ —
160' AZIMUTH h I DRAWING FILE
� _ _ _ _ ,�
II 11 I URBAN \35DARTMOUTH
EXISTING GRADE ZWDARTMOUTHLTE -A04
I ' \V
197.00AMSL
SHEET TITLE
1 PANEL ANTENNA AZIMUTH PLAN 2 SITE ELEVATION ANTENNA INFORMATION
A04 1 / 8 " = 1 ' - o" Ao ," = 10'_0„ SITE ELEVATION
\ SHEET NUMBER
A04