Specifications . CITY OF T �GA� „„7 Northwest Fire Suppression, Inc. EQUIPMENT SUBMITTAL FOR Greenburg Space Center 11125 Southwest Greenburg Road . Tigard, Oregon 97223 • SYSTEM Sprinkler Monitoring System • CONTENTS Manufacture Data Sheets • DESIGNED BY: Albert Bryant, C.E.T. 15385 SW Beaverton Creek Court Beaverton, OR 97006 (503) 644 -7720 Tel (503) 644 -8289 Fax • • • • • • dn- 60185:b SFP- 5UD(E) /SFP -1 OUD(E) T 1 F 1 E R Five Zone Fire Alarm Control Panel Clj 101 ® Ten Zone Fire Alarm Contrrol Panel - - `- — - - e - - -^ • -- -- -- • y oneywell ' Conventional Fire•Alarm Control Panels General The SFP -5UD is a five -zone FACP (Fire Alarm Control Panel) and the SFP -10UD is a ten -zone FACP. These control panels provide reliable fire signaling protection for small to medium- sized commercial, industrial, and institutional buildings. Both • panels include built -in communicators for Central Station Ser- _•.. vice and remote upload/download. . - :V° Each of these FACPs compatible with System Sensor's r microprocessor -based i series detectors. These conventional j- . �.� • smoke detectors can transmit a maintenance trouble signal to r: ": _�? - the FACP indicating the need for cleaning and a supervisory "freeze" signal when the ambient temperature falls below the detector rating. Additionally, both the SFP -5UD and . SFP - 10UD are compatible with conventional input devices such as g two -: and four -wire smoke detectors, pull stations, waterfiow • • devices, tamper switches, and other normally -open contact • • devices. Refer to the Notifier Device Compatibility Document.' for a complete listing of compatible devices. Outputs include four NACs (Notification - Appliance Circuits), three programmable Form -C relays (factory programmed for • Optional N- CAC -5X Style Z (Class A) Converter Module for Alarm, Trouble, and Supervisory) and 24 VDC special applica- NACs and IDCs (2 required for SFP- 10UD). tion resettable and nonresettable power outputs: - The FACPs • - Form -C Relays for Alarm, Trouble and Supervisory - Con - supervise all wiring, AC voltage, battery level and telephone tact Ratings 2.0 A@ 30 VDC or 30 VAC (resistive). line integrity. • • 3.0 A total system current for SFP -5UD. Activation of a compatible smoke detector or any normally- • 7.0 A total system current for SFP -10UD. open fire alarm initiating device will activate audible and visual • Optional Trim Ring TR -CE/ -B for semi -flush mounting. signaling devices, illuminate an indicating LED, sound the piezo sounder at the FACP, activate the communicator and • 24 volt operation. • FACP alarm relay, and operate an optional" module used to • Low.AC voltage - sense. notify a remote station or initiate an auxiliary control function. • Alarm Verification. • • • The SFP -5UDE and the SFP -10UDE offer the same features • PAS (Positive Alarm Sequence). as the SFP -5UD and SFP -10UD but allow connection to 220/ - • Automatic battery trickle charger. 240.VAC. • • • • - Optional Remote Annunciator N- ANN -80. • NOTE: Unless otherwise specified, the information in this data • Optional Remote Printer Gateway N- ANN -S /PG. sheet applies to. both the 110/120 VAC and the 220/240 VAC ver- sions of these panels. • • Optional LED Annunciator Driver N- ANN -I/O. • Optional 4XTM module (conventional reverse polarity /city Features . - box transmitter). • • Listed to UL Standard 864, 9th edition. PROGRAMMING AND SOFTWARE: • Built -in DACT (Digital Alarm Communicator/Transmitter). • Can be programmed at the panel with no special software • Style B (Class B) IDC (Initiating Device Circuit) or additional equipment. - SFP -5UD - five' IDCs. • Programmable Make /Break Ratio. - SFP -10UD - ten IDCs. USER INTERFACE: • Style Y (Class B) NAC (Notification Appliance Circuit) - spe- • Built -in DACT (Digital Alarm Communicator/Transmitter). cial application power -SFP 5UD -four NACs. • Integral 80- character - LCD display with backlighting and keypad. - SFP- 10UD.- four NACs. • Real -time clock/calendar with automatic daylight savings • Notification Appliances'may be programmed as adjustments. - Silence Inhibit: - • ANN -BUS for connection to remote annunciators. - Auto - Silence. • Audible or silent walk test capabilities. - Strobe Synchronization for System Sensor, Wheelock, • Piezo sounder for alarm, trouble, and supervisory. • Gentex, Faraday, or Amseco devices. - Selective Silence (horn- strobe mute). - Temporal or Steady Signal. - Silenceable or Nonsilenceable. • dn- 60185:b • 04/16/08 — Page 1 of 4 • • • • • • Controls and Indicators • SFP -10UD (FLPS -7 Power Supply): 120 VAC, 50/60 Hz, 3.8 A. LED INDICATORS • SFP -10UDE (FLPS -7 Power Supply): 220 VAC, 50 HZ, • FIRE ALARM (red) - -- - - — ... _ .2.20.A. - - — — - - -- - --• - - • SUPERVISORY (yellow) Wire size: minimum 14 AWG (2.00 mm with 600 V insulation. • TROUBLE (yellow) Supervised, nonpower - limited. • AC POWER (green) • Battery (sealed lead acid only) - J12: • ALARM SILENCED (yellow) • Maximum Charging Circuit - Normal Flat Charge: 27.6 VDC CONTROL BUTTONS ® 1.4 A. Supervised, nonpower - limited. • Maximum Charger Capacity: 18 AH battery for SFP- • ACKNOWLEDGE 5UD(E), and 26 AH battery for SFP- 10UD(E). [Two 18 Ah • ALARM SILENCE batteries can be housed in the FACP cabinet. Larger batter- • SYSTEM RESET (lamp test) ies require separate battery box such as the BB -26 or NFS- • DRILL LBB.] • Minimum Battery Size: 7 AH. Terminal Blocks Initiating Device Circuits - TB4 (and TB 6 on SFP -10UD only): AC Power - TB1: • Alarm Zones 1 - 5 on TB 4 (SFP -5UD and SFP- 10UD). • SFP -5UD (FLPS -3 Power Supply): 120 VAC, 50/60 HZ, • Alarm Zones 6 - 10 on TB6 (SFP -10UD only). •1.00 A. • SFP -5UDE (FLPS -3 Power Supply): 220 VAC, 50 HZ, Supervised and power limited circuitry. • 0.54 A. • Operation: All•zones Style B (Class B). • • Normal Operating Voltage: Nominal 20•VDC. Top _;_ 4, ..7-..'..,:t-- 4- • -. ' Depth l = 5.207" (13.23 cm) ter_-_, �; `�'�:,.� --AIM __Door = 16.821" (42.73 cm)__ Depth = . Backbox = 16.65" (42.29 cm) I 1 257 " — (13.353 cm) qi_ hg__ i ce, ; • . E- --• ` ,tt ' 2 . } rte , W7li tt.- _: _ 7 — 14.:; -= } . , el. • - � ._'_ �: =_ �!;sr_- a: ,• FA ;4.... . = • .• rW Door = 19.26" (48.92 cm) - -._ : V - Y - ;_ Backbox = 19.0" (48.26 cm) r : A- = „:��.•�_•z:: - : _ • Pt, , rret, � mac - Rs. -`• .: s k '.�•'�"_� _ ,,,,s ir _ §3t:i' e ' rs- 'i_`�. s WINL-4. 'i_ - W4f.T - flt -r F.,: ..a. . :""r.:F." - .5: atiA Fl E rte . :Fi . i -....;,..4, Left Side • Right Side nti: .:�. : ;;: : :e - - - -- _.. - - -_ -, -- - - -_ _ •;'mot Bottom 3, `i' _ ' -�_�i , • ; , �,�..- _ Cabinet Measurements Page 2 of 4 — dn- 60185:b • 04/16/08 • • • • • • Alarm Current: 15 mA minimum. • (Class A). Connects to J2 on the SFP -5UD and SFP -10UD • Short Circuit Current: 40 mA max. main circuit board and to J7 on the SFP -10UD. • Maximum Loop Resistance: 100 ohms. NOTE: Two Class A Converter Modules are required for the ten - • End-of-Line Res 4.7K ohm, 1/2 watt (P /N 71252 UL- -zone panel.- -- -- - - -- - - - - -- - — -- - - - - - - -- listed). 4XTM: Transmitter module. Provides a supervised output for • Standby Current: 2 mA. local energy municipal box transmitter and alarm and trouble reverse polarity. Includes a disable switch and disable trouble Refer to the Notifier Device Compatibility Document for listed LED. A module jumper option allows the reverse polarity circuit compatible devices. to open with a system trouble condition if no alarm conditions Notification Appliance Circuits - TB5 (and TB 7 on SFP- exists. Mounts to the main circuit board connectors J4 and J5. 10UD only): COMPATIBLE ANNUNCIATORS • Four NACs • N- ANN -80: Remote LCD Annunciator. Mimics the information • Operation: Style Y (Class B) displayed on the FACP's LCD. • Special Application power N- ANN -S/PG: Serial /parallel printer gateway. Provides a con- • Supervised and power - limited circuitry nection for a serial or parallel printer. • Normal Operating Voltage: Nominal 24 VDC N- ANN -I/O: Driver module. Provides connections to a user- • Maximum Signaling Current: 3.0 A for SFP- 5UD(E), 2.5 A supplied graphic annunciator. maximum per NAC; 7.0 A for SFP- 10UD(E), 3.0 A maxi- mum per NAC. ACCESSORIES • End -of -Line Resistor: 4.7K ohm, 1/2 watt (Part #71252) BB -26: Battery backbox, holds up to two 25 AH batteries and • Max. Wiring Voltage Drop: 2 VDC - CHG -75. Refer to the Notifier Device Compatibility Document for com- NFS -LBB: Battery backbox, holds up to two 55 AH batteries. patible listed devices Black. Form C Relays - TB8: NFS -LBBR: Same as above in red. • Relay 1 (factory default programmed as Alarm Relay) TR -CE -B: Optional black trim -ring for semi -flush mounted cab- • Relay 2 (factory default programmed as fail -safe Trouble inets. Relay) TR -CE: Same as above in red. • Relay 3 (factory default programmed as Supervisory Relay) Special Application Resettable Power - TB9: • • Jumper selectable by JP31 for resettable or nonresettable power. • Operating voltage: 24 VDC nominal. • Maximum available current: 500 mA - appropriate for pow- ering four -wire smoke detectors. • Power - limited circuit. Refer to the Notifier Device Compatibility Document for listed compatible devices. - Remote Sync Output - TB2: Remote power supply synchro- r nization output, only required for the SFP- 5UD(E). 24 VDC • nominal special application power. Maximum current is 40 mA. End -of -Line Resistor: 4.7K ohm. Supervised and power -lim- ited circuit. Ordering Information SFP -5UD: Five -zone, 24 -volt Fire Alarm Control Panel (includes black backbox, FLPS -3 power supply, technical man- ual, and a frame & post operating instruction sheet). SFP -SUDR: Same as above in a red backbox. SFP -5UDE: Same as above with 220 VAC FLPS -3 power sup- ply. SFP -10UD: Ten -zone, 24 -volt Fire Alarm Control Panel (includes black backbox, FLPS -7 power supply, technical man- ual, and a frame & post operating instruction sheet). SFP- 10UDR: Same as above in a red backbox. SFP- 10UDE: Same as above with 220 VAC FLPS -7. OPTIONAL MODULES N- CAC -5X: Optional (Class A) Converter Module. Converts Style B (Class B) Initiating Device Circuits to Style D (Class A); and Style Y (Class B) Notification Appliance Circuits to Style Z dn- 60185:b • 04/16/08 — Page 3 of 4 • SYSTEM SPECIFICATIONS System Capacity Temperature and Humidity Ranges • Annunciators 8 This system meets NFPA requirements for operation at 0 — 49 °C/32 — 120 °F and at a relative humidity 93% t 2% RH Electrical Specifications (noncondensing) at 32 °C t 2 °C (90 °F ± 3 °F). However, the useful life of the system's standby batteries and the electronic • SFP -5UD (FLPS -3 Power Supply): 120 VAC, 50/60 HZ, components may be adversely affected by extreme tempera - 1.0 A ture ranges and humidity. Therefore, it is recommended that • SFP -1.0UD (FLPS -7 Power Supply): 120 VAC, 50/60 HZ, this system and its peripherals be installed in an environment 3.8 A with a normal room temperature of 15 — 27 °C /60 — 80 °F. • SFP -5UDE (FLPS -3 Power Supply): 240 VAC, 50/60 HZ, 0.54 A Agency Listings and Approvals • SFP -10UDE (FLPS -7 Power Supply): 240 VAC, 50/60 HZ, The listings and approvals below apply to the basic SFP -5UD 2.2 A and SFP -10UD control panels. In some cases, certain mod- • Wire size: minimum 14 AWG (2.0 mm with 600 V insula- ules or applications may not be listed- by certain approval tion, supervised, nonpower - limited agencies, or listing may be in process. Consult factory for lat- . est.listing status. • Cabinet Specifications • UL Listed: File S635 Door: 19.26° (48.92 cm.) high x 16.82° (42.73 cm.) wide x • FM Approved 0.72° (1.82 cm.) deep. Backbox: 19.00° (48.26 cm.) high x • CSFM: 7165- 0028:246 16.65° (42.29 cm.) wide x 5.25° (13.34 cm.) deep. Trim Ring • MEA: MEA: 333 -07 -E (TR -CE): 22.00° (55.88 cm.) high x 19.65° (49.91 cm.) wide. NFPA Standards Shipping Specifications The SFP- 5UD(E) /SFP- 10UD(E) complies with the following Dimensions: NFPA 72 Fire Alarm Systems requirements: — 20.00° (50.80 cm.) high — LOCAL (Automatic, Manual, Waterflow and Sprinkler — 22.5° (57.15 cm.) wide Supervisory). — 8.5° (21.59 cm.) deep. — AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTM). — REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTM is required.) — PROPRIETARY (Automatic, Manual and Waterflow). - CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). NOTIFIER@ and System Sensor@ are registered trademarks of Honeywell International Inc. ©2008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up -to -date and accurate. • G E R T t F E We cannot cover all specific applications or anticipate all requirements. • E®NEBi1NO All specifications are subject to change without notice. QUALITY SYSTEMS Made In the U.S. A. For more information, contact Notifier. Phone: (203) 484 -7161, FAX: (203) 484 -7118. www.notifier.com Page 4 of 4 — dn- 60185:b • 04/16/08 • DN- 7049:A • I -95 1 00 Series N OTI F 1 E R 100 Series Low - Profile Plug -In Smoke Detectors by Honeywell Conventional Initiating Devices General - 100 Series Plug -in Smoke Detectors offer superb performance and reliability in a profile which is just 2" (5.1 cm) deep. Model 2151 (photoelectric sensor) and model 2151T (photoelectric sensor with thermal) can be used with a variety of different adapter bases in several wiring configurations and voltages. Other features include: low current draw, stable performance in ' high air velocities, built -in tamper resistant base design, remote LED option, removable cover, and built -in test switch. p The 100 Series is designed to meet the performance criteria designated by UL. Its sensing chambers are sealed against back pressure air flow, dirt, and insects. This chamber is pro- tected by a fine mesh screen which can be cleaned or Agency Listings and Approvals replaced. Additional key features include a variety of mounting bases and a full line of accessories. These listings and approvals apply to the modules specified in All 100 Series photoelectric smoke detectors contain a unique this document. In some cases, certain modules or applications optical sensing chamber designed to sense smoke particles may not be listed by certain approval agencies, or listing may produced by a wide range of combustion sources. A custom be in process. Consult factory for latest listing status. integrated circuit incorporates signal processing to reduce • UL Listed: S911 false alarms. • ULC Listed: CS308 Model 2151 photoelectric detector's unique optical sensing • CSFM: 7272-1653:122 chamber is engineered to sense smoke by a wide range of • FM Approved combustion sources. Dual electronic thermistors add 135 °F • MEA Approved: 205-94-E fixed temperature thermal sensing on model 2151T. • Maryland State Fire Marshal: #2180 Specifications Product Line Information Operating Voltage/Alarm Current: See Adapter Base Selection Guide following 2151: Low - profile photoelectric detector. Must be mounted to • Standby Current: 85pA Standby one of the B100 Series or B400 Series bases listed in the Adapter Base Selection Guide. Sensitivity: 1 - 3.18 % /ft. 2151T: Low - profile photoelectric detector with thermal. Must Height: 2.0" in B401 be mounted to one of the B100 Series or B400 Series bases Diameter: 4.1" installed in B401; 6.2" installed in B110LP listed in the Adapter Base Selection Guide. Shipping Weight: 5.2 oz F110: Retrofit replacement flange for B400 Series flanged bases. Construction: Flame retardant thermoplastic RA400Z: Remote annunciator for 2 or 4 wire systems, 3 -32V. Temperature: Photo: 32 °F to 120 °F (0 °C to 49 °C); Fits standard single gang electrical box. Photo/Thermal: 32 °F to 100 °F (0° to 38 °C) 8401 BH -2: Sounder base. Requires an external 24 VDC UL Listed Velocity Range: Photo: 0 -3000 fpm (0 -15.2 m/s) power supply. Mounts to 4" square electrical box (112" mini - Humidity Range: 10 % -93% RH non - condensing mum depth, 218" recommended). Smoke Detector Spacing: On smooth ceilings (as defined in SENS -RDR: Hand -held sensitivity reader. NFPA 72), spacing of 30 feet (900 sq. ft.) may be used as a SMK400: Surface mounting kit provides for entry of surface guide. Other spacing may be used depending on ceiling wiring conduit. For use with B401 or 8401 R mounting bases height, high air movements, and other conditions or response only. requirements. EOLR -1: End of line relay for power supervision, 12/24 VDC systems. MO2 -04-01: Test magnet. MO2 -09 -00: Test magnet with 32° telescoping handle. XR -2B: Detector removal tool. Allows installation and/or removal of 100 Series detector heads from base in high ceiling installations when used with XP-4. XP -4: Extension pole for XR -2B. Comes in three 5 ft. sections. C58- 227 -01: Replacement dust cover for 100 Series smoke • detectors. RMK400: Recessed mounting kit (B401 sold separately). DN -7049 A • 4/4/08 — Page 1 of 2 • - Adapter Base Selection Guide . • Current - • Base Model Number Loop Limit Resis- Contact Type Nominal Current Draw on _ - -- — --- -- _Type_ - —tor— -•- -- -- - - - --- -- Voltage- - — Alarm (mA) - -- — - - — ___ — - - B110LPB401t 2 -wire' No • — 12/24 VDC 10 -130" B11ORLPB401RtB401BRt 2 -wire* Yes — • 24 VDC 10 -62 . B112LPB402t 4 -wire • Yes Form A & C 24 VDC 17 -36 . B114LPB404t 4 -wire - •Yes Form A & C + A Supervisory 120 VAC 75 mA AC maximum B116LPB406t 2 -wire* • No - Form C • 24 VDC 20 -100" B401t . • 2 -wire* No • —. 12/24 VDC 10 -100" . • Functionality contingent on panel compatibility. ' '• Must be limited by control panel. t Flangeless base. Relay Contact Ratings: Resistive or inductive (60% power factor) load. Form A: 2.0 A at•30.VAC/DC - Form C: 0.6 A at 11 OVDC, 2.0 A at 30 VDC 1.0 A at 125VAC, 2.0 A at 30 VAC • Junction Box Selection Guide* - Base Model' Single 3 -1 4 "Octagon 4 Square . 50 mm 60 mm 75 mm Number Gang ' Oct;3gon B401 No No . No . No . • • Yes Yes No B110LP/RLP Yes. Yes Yes Yes • No • • .• No -• No . B112LP /B116LP Yes Yes • • Yes Yes Yes . Yes Yes B114LP No . No Yes Yes No • - No No • Box depth contingent on base and wire size. Refer to National Electrical Code or local applicable codes for appropnate recommenda- - tions. • • • • 02008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. • • 1809001 This document is not intended to be used for installation purposes. We try to keep our product Information up-to -date and accurate. C R T F E D We cannot cover all specific applications or anticipate all requirements. ■ • ENCI lE11ll11 8 MANUIUIJ • All specifications are subject to change without notice. QUALITY. SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484 -7118. www.notifier.com Page 2 of 2 — DN- 7049:A • 4/4/08 DN- 6643:A1 • 1-410 NBG - 12 Series NOTI FI E R Non -Coded Conventional Manual Fire Alarm Pull Stations by Honeywell Conventional Initiating Devices General _ The NOTIFIER NBG -12 Series is a cost - effective, feature- 1 packed series of non -coded manual fire alarm pull stations. It F I R E was designed to meet multiple applications with the installer and end -user in mind. The NBG -12 Series features a variety of mod- els including single- and dual- action versions. {{ PUS1i 1!2 The NBG -12 Series provides an alarm initiating input signal to *PULL 0071t: r conventional fire alarm control panels (FACPs) such as the 1 ' SFP Series, and to XP Transponders. Its innovative design, l , durable construction, and multiple mounting options make the NBG -12 Series simple to install, maintain, and operate. Features fJNUTIFI L "H ` • Aesthetically pleasing, highly visible design and color. • Attractive contoured shape and light textured finish. - • Meets ADA 5 lb. maximum pull- force. 1PB • Meets UL 38, Standard for Manually Actuated Signaling Boxes. • Easily operated (single- or dual- action, model dependent), Construction yet designed to prevent false alarms when bumped, shaken, or jarred. • Cover, backplate and operation handle are all molded of • PUSH IN /PULL DOWN handle latches in the down position to durable polycarbonate material. clearly indicate the station has been operated. • Cover features white lettering and trim. • The word "ACTIVATED" appears on top of the handle in • Red color matches System Sensor's popular SpectrAlert® bright yellow, further indicating operation of the station. Advance horn/strobe series. • Operation handle features white arrows showing basic opera- tion direction for non - English- speaking persons. Operation • Braille text included on finger -hold area of operation handle The NBG -12 manual pull stations provide a textured finger -hold and across top of handle. area that includes Braille text. In addition to PUSH IN and PULL • • Multiple hex- and key -lock models available. DOWN text, there are arrows indicating how to operate the sta- • U.S. patented hex -lock needs only a quarter -turn to lock/ tion, provided for non - English- speaking people. unlock. Pushing in and then pulling down on the handle activates the • Station can be opened for inspection and maintenance with- normally -open alarm switch. Once latched in the down position, out initiating an alarm. the word "ACTIVATED° appears at the top in bright yellow, with a • Product ID label viewable by simply opening the cover; label portion of the handle protruding at the bottom as a visible flag. is made of a durable long -life material. ' Resetting the station is simple: insert the key or hex (model • The words "NORMAL" and "ACTIVATED" are molded into the dependent), twist one quarter -turn, then open the station's front plastic adjacent to the alarm switch (located inside). cover, causing the spring - loaded operation handle to return to • Four - position terminal strip molded into backplate. its original position. The alarm switch can then be reset to its • Terminal strip includes Phillips combination -head captive 8/32 normal (non alarm) position manually (by hand) or by closing screws for easy connection to Initiating Device Circuit (IDC). the station's front cover, which automatically resets the switch. • Terminal screws backed -out at factory and shipped ready to accept field wiring (up to 12 AWG/3.1 mm Specifications • Terminal numbers are molded into the backplate, eliminating PHYSICAL SPECIFICATIONS: the need for labels. • Switch contacts are normally open. pull station SB - 10 SB WBB WP - 10 • Can be surface - mounted (with SB -10 or SB -1/O) or semi- H 5.500 in. 5.500 in. 5.601 in. 4.25 in. 6.000 in. flush mounted. Semi -flush mount to a standard single -gang, (13.97 cm) (13.97 cm) (14.23 cm) (10.79 cm) (15 24 cm) double -gang, or 4" (10.16 cm) square electrical box. 4.121 in. 4.125 in. 4.222 in. 4.25 in. 4.690 in. • Backplate is large enough to overlap a single -gang backbox IA, (10.467 cm) (10.478 cm) (10.72 cm) (10.79 cm) (11.913 cm) cutout by 1/2" (1.27 cm). 1.390 in. 1.375 in. 1.439 in. 1.75 in. 2.000 in. • Optional trim ring (BG12TR). D (3.531 cm) (3.493 cm) (3.66 cm) (4.445 cm) (5.08 cm) • Spanish versions (FUEGO) available (NBG- 12LSP, NBG- 12LPSP). - 6543dJm2 tbl • Designed to replace the legacy NBG -10 Series. • Models packaged in attractive, clear plastic (PVC), clam- ELECTRICAL SPECIFICATIONS: shell - style, Point -of- Purchase packages. Packaging includes Switch contact ratings: gold - plated; rating 0.25 A @ 30 VAC or a cutaway dust/paint cover in shape of pull station. VDC. Auxiliary contact circuit (Terminals 3 & 4, NBG-1 2LA): • rated to 3.0 A @ 30 VAC or VDC. DN- 6643:A1 • 04/22/08 — Page 1 of 2 • ENGINEERING/ARCHITECTURAL SPECIFICATIONS NBG- 12LPSP: Same as NBG -12LPS with English/Spanish Manual Fire Alarm Stations shall be non -code, with a key- or (FIRE/FUEGO) labeling. - hex - operated reset lock in order that they may be tested, and so NBG- 12LOB: Dual- action pull station with key lock, outdoor . designed that after actual Emergency Operation, they cannot be applications listings (NBG- 12L0), and backbox. Includes SB -I/O restored to normal except by use of a key or hex. An operated indoor /outdoor backbox, and sealing gasket. Model will also station shall automatically condition itself so as to be visually mount to WP -10 weatherproof backbox in retrofit applications. detected as activated. Manual stations shall be constructed of NOTE: NBG -12L0 not available separately; red colored LEXAN (or polycarbonate equivalent) with clearly NBG -12L0 + approved backbox = NBG- 12LOB. visible operating instructions provided on the cover. The word Outdoor applications listings apply to NBG -12LOB combination. FIRE shall appear on the front of the stations in white letters, NBG -12LA: Dual- action pull station with key lock and annuncia- 1.00 inches (2.54 cm) or larger.' Stations shall be suitable for tor contacts. surface mounting on matching backbox SB -10 or SB -I /O; or SB -10: Surface -mount backbox, metal. semi -flush mounting on a standard single -gang, double -gang, or SB -I/O: Surface -mount backbox, plastic. (Included with NBG - 4" (10.16 cm) square electrical box, and shall be installed within 12LOB.) the limits defined by the Americans with Disabilities Act (ADA) or BG12TR: Optional trim ring for semi -flush mounting. per national/local requirements. Manual Stations shall be Under- writers Laboratories listed. WP -10: Outdoor use backbox. NOTE: 'The words " FIRE/FUEGO" on the NBG -12LSP and NBG- Keys, set of two. (Included with key -lock pull stations.) 12LPSP shall appear on the front of the station in white letters, 17007: Hex key, 9/64 °. (Included with hex -lock pull stations.) approximately 3/4° (1.905 cm) high. NOTE: For addressable NBG -12LX models, see data sheet DN -6726. Pre - Signal Models 1.390 The NBG -12LPS and NBG- 12LPSP pull stations are non -coded (3531) Dimensions manual pull stations which provide a FACP with two normally open alarm initiating input signals. "Pre - signal" input is activated - ■ by pushing in, then pulling down, the dual- action handle. A "gen- Strip Wire Length eral" alarm input signal can be manually activated via a momen- / ` tary rocker switch mounted inside the unit. This general alarm r switch can only be accessed by opening the cover with the sup- 1.000• plied key/lock. See diagram at right. (2.540) Agency Listings and Approvals The listings and approvals below apply to the NBG -12 Series 0.150• pull stations. In some cases, certain modules may not be listed 11 905) 5.500' by certain approval agencies, or listing may be in process. Con- (13.970) suit factory for latest listing status. 1 . • C(UL)US Listed: file S692. (cm) • CSFM approved: file 7150 - 0028:199. L • FM approved (except NBG- 12LPS, NBG- 12LPSP). . • MEA approved: file 67 -02 -E (NBG -12, NBG -12L, NBG- 12LOB, 1 • NBG- 12LA). • Lloyd's Register type approved: file 93/60141 (E3) (NBG -12, NBG - 12LPS NBG -12L, NBG -12LA, NBG- 12LOB, NBG -12S). . • U.S. Coast Guard approved: files 161.002/23/3 (AFP -200 with NBG -12, NBG -12L, NBG -12S); 161.002/42/1 (NFS -640 with PRODUCT NBG -12, NBG -12L, NBG -12S); 161.002/27/3 (AFP1010/ IDENTIFICATION LABEL AM2020 with NBG -12, NBG -12L, NBG -12S). • Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; ROCKER I__. MpL TOGGLE 6,632,108. SWITCH r� PUSH FOR K SWITCH GENERAL for General 01111 ALARM for Pro - Signal Alarm i�i .—1 A function Product Line Information notification fk • c r - A rEo NBG -12S: Single -action pull station with pigtail connections, v _ I hex lock. 4 NBG -12: Dual- action pull station with SPST N/O switch, screw terminal connections, hex lock. NBG -12L: Dual- action pull station with SPST N/O switch, screw terminal connections, key lock. NOTIFIER ®, SpectrAlert® Advance, and System Sensor® are registered trademarks of Honeywell International Inc. NBG 12LSP: Same as NBG - 12L with English/Spanish (FIRE/ ®2008 by Honeywell International Inc. All rights reserved. Unauthorized use FUEGO) labeling. of this document is strictly prohibited. NBG 12LPS: Dual action pull station with pre - signal option. iso 9001 This document is not intended to be used for installation purposes. :::: :: We try to keep our product information up -to -date and accurate. G E R T F E We cannot cover all specific applications or anticipate all requirements. ■ • MIMOSA 8 MAXIMUMS All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484 -7161, FAX: (203) 484 -7118. - www.notifier.com Page 2 of 2 — DN- 6643:A1 • 04/22/08