Plans FP-52e l (- 0009 2 1 5115 5 1/✓ ?k_LA. 1( t&5C17 I Fire & Building Products Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 Series TY -FRB — 2.8, 4.2, 5.6, and 8.0 K- factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage • tained when exposed to corrosive at- General mospheres. Although corrosion resis- tant coated sprinklers have passed the - 4 Description standard corrosion tests of the appli- 'j ' cable approval agencies, the testing is r,.n /4 1 ° The Tyco® Series TY -FRB, 2.8, 4.2, not representative of all possible cor- - + 5.6, and 8.0 K- factor, Upright and Pen- rosive atmospheres. Consequently, it I dent Sprinklers described in this data is recommended that the end user be sheet are quick response - standard consulted with respect to the suitability 2 coverage, decorative 3 mm glass bulb of these coatings for any given corro- , e type spray sprinklers designed for use sive environment. The effects of ambi- _ in light or ordinary hazard, commercial ent temperature, concentration of -- i occupancies such as banks, hotels, chemicals, and gas /chemical velocity, 1 shopping malls, etc. should be considered, as a minimum, The recessed version of the Series along with the corrosive nature of the TY -FRB Pendent Sprinkler, where a - chemical to which the sprinklers will be P P plicable, is intended for use in areas exposed. . ` with a finished ceiling. It uses either a An intermediate level versions of the two -piece Style 10 (1/2 inch NPT) or Series TY -FRB Pendent Sprinklers Style 40 (3/4 inch NPT) Recessed Es- are detailed in Technical Data Sheet . f V , cutcheon with 1/2 inch (12,7 mm) of TFP356, and Sprinkler Guards are de- recessed adjustment or up to 3/4 inch tailed in Technical Data Sheet TFP780 l (19,1 mm) of total adjustment from the - . flush pendent position, or a two -piece WARNINGS . alas 20 (1/2 inch NPT) or Style 30 (3/4 The Series TY - FRB Sprinklers de - •� - ` inch NPT) Recessed Escutcheon with scribed herein must be installed and . � � 1/4 inch (6,4 mm) of recessed adjust maintained in compliance with this ment or up to 1/2 inch (12,7 mm) of document, as well as with the applica- total adjustment from the flush pen ble standards of the National Fire Pro - dent position. The adjustment pro tection Association, in addition to the vided by the Recessed Escutcheon re- standards of any other authorities hay- Model /Sprinkler duces the accuracy to which the fixed ing jurisdiction. Failure to do so may pipe drops to the sprinklers must be impair the performance of these de- Identification cut. vices. Corrosion resistant coatings, where The owner is responsible for maintain- Numbers applicable, are utilized to extend the ing their fire protection system and de- life of copper alloy sprinklers beyond vices in proper operating condition. TY1131 - Upright 2.8K, 1/2 "NPT that which would otherwise be ob The installing contractor or sprinkler TY1231 - Pendent 2.8K, 1/2 "NPT manufacturer should be contacted TY2131 - Upright 4.2K, 1/2 "NPT with any questions. TY2231 - Pendent 4.2K, 1/2 "NPT IMPORTANT TY3131 - Upright 5.6K, 1/2 "NPT Always refer to Technical Data TY3231 - Pendent 5.6K, 1/2 "NPT Sheet TFP700 for the "INSTALLER TY4131 - Upright 8.0K, 3/4 "NPT WARNING" that provides cautions TY4231 - Pendent 8.0K, 3/4 "NPT with respect to handling and instal- TY4831- Upright 8.0K, 1/2 "NPT lation of sprinkler systems and corn- TY4931- Pendent 8.0K, 1/2 "NPT ponents. Improper handling and in- s stallation can permanently damage I a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. .Page 1 of 10 AUGUST, 2007 TFP171 [Page Too Large for OCR Processing]