Specifications FPS?C I Z.- 00073 I 7_735 s w American Security Alarms, Inc. 5411 SE McLoughlin Blvd., Portland, OR. 97202 (503) 231 -0303 PROPOSAL COMMERCIAL FIRE ALARM SYSTEM Attn: Barry Lucas April 6, 2012 Holland Inc. RE: Burgerville USA 12765 SW Pacific Highway, Tigard, OR. 97223 Manual Pull Station: 1 — Manual Pull Station at Fire Alarm Control Panel Area Fire Alarm Warning Device: 1 — Fire Horn Strobe Light at Fire alarm Control Panel Area Smoke Detectors: 1 — Smoke Detector in above Control Panel Area 2 — Connections to HVAC Duct Smoke Detectors (Provided by HVAC contractor or Others) Fire Suppression System: 1 — Connection to Fire Suppression system Relay for 24 -hour Monitoring System Control Equipment: 1 — Upgrade Master Control Panel V2OP to V32FBP Fire /Security Alarm Control Panel 1 — Master Control Panel — Honeywell Vista 32FB • 8 Hardwire zones - expands to 24 hardwire zones & 32 wireless zones • event log up to 520 events • 75 user codes, 2 sub -area controls & Access Control • Commercial rated for Fire/Security Alarm System 2 — Rechargeable Battery Back -ups 2 — Connections to American Security Alarms Central Station for 24 -hour dispatch 1 — 24 -hour Daily Timer Test Signal enable to report Installation: $1,595.00 Installed, Labor & Materials $ 10.00 Monthly Charge, 24 -hour Central Station Monitoring ► Requires Standard 36 month agreement ► Includes a one year warranty on all parts and labor ► Electrical /Fire permit(s) and fire plan preparation /submittal are additional charges ► Commercial UL Fire Alarm Systems require Customer provided Dedicated NC with a red marked lock -out breaker. This requirement is to be performed by a licensed high voltage technician. In the event American Security Alarms provides a third party contractor it will be at additional cost. ► Proposal is subject to approval of Authority having Jurisdiction. Customer is responsible for additional requirements made by Authority having Jurisdiction upon plan review or inspection. Approved: Date: V// THE SECURITY PROFESSIONALS...SINCE 1970 . . Battery • ' ' Honeywell Security ' cont Facility Information Enter Standby and Alarm Times Factor 1 •..1i -; j. •:r,'r.1 ; i-trj,1t Location: BurgervIlle USA Battery Standby (hours): 24 et: 203 Honeywell lnle,nawnal Inc All l:vhts ricse ved Account #: 12766 SW Pacific Highway, Tigard, OR ' Alarm Duration (minutes): 5 1o9'e 0 Apply UL Power Limbs? Model: Vista 32FB - (Required to maintain UL Usbng) • Engineer: Rich Miller I Commercial Fire Installation Recommende 0 Date: 5/7/2012 10.0 ['Commercial Burg Installation Battery (AHJ SELECTED PANEL MAXIMUM OUTPUT RATINGS Poll/n Standby Alarm Panel Boll of Bell a1 CI g Auxilia Auxilia Standb Panel Maximum Panel Panel Max Battery Select Panel from UIIrtOWn list: Loop (mA) ry ry y Alarm (mA) Output Output (It Supported by Panel P Power (mA) Power (mA) (mA) Standby Output Alarm Output (mA) used; mA) l M vista -32FB 128 750 1000 300 470 1700 1700 1000 2300 34.4 Total Standby Total Alarm Calculated Current Draw 6 50 165 Calculated Bell Draw of 0 56 171 Standby Budget Alarm Budget Power Budget 122 0 700 0 835 0 Bell Power Budget 1700 0 1 1700 0 944 0 2129 0 0 Remove Unused Devices From List • External Bell Power Req'd (mA): 0 0 Ext. UL Power Req'd (mA): 0 J I Grayed -out device(s) are not supported by selected panel How many Total Enter powered Standby (aux Alarm Total Polling Standby Total External KEYPADS /INTERFACES Quantity externally? pm) Current (Aux) Polling Loop Loop Current Total Alarm Current Current Required N.z, \ q `'\ \ \\ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \\ \ \ \ \ \ \ \ \i \ \ \ \ \ \ \ \ \ \ \ N ' I3 \\\\\\\\\\\\\\\\\\\\\\\\\\\\ \ \ \ \ \ \ \ \N \ \ \ \ \\ \ \ \ \ \\ N. -- - --------- - - — • U � \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \\ \\\ \ \ \ \: \ \ \ \ \ \ \:� \ \ \ \ \ \ \x \ \ \ \ \ �� 1' '1 �` \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \\ III \ \ \ \ \\ \ \ \ \ \\ \ \ \ \ \ \ \ \\ \ \ \ \ \ \ \\ 6160/6160CR 1 0 NI 150 \ \ \ N 45 150 0 U \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \\ \ \ \ \ \\ ' \ \ \ \ \`l � \ \ \ \ \ \ \\\ _ s4 �tih\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ \\r� \ �`& N '\\ IMilMIIMI\ \ \ \ \M \ \ \ \M & \ \ \ \ \. 2 WIRE & 4 WIRE SMOKE DETECTORS How many Total Enter powered Standby (aux Alarm Total Polling1 Standby I Total External (except Vplex Polling Loop detectors) Quantity externally? : pwr) Current (Aux) Pollingloop • Loop Current Total Alarm Current Current Required 2 wire smoke detector (zone powered) I 1 Two -wire smoke detector current is built Into the panel budgets These fields are included to help you create a complete equipment lest The line below indicates ,f number of detectors exceeds panel \ \ \\ \ \ \ \ \ \ \ \\ capacity, or if the selected panel does not support 2 -wire smoke detectors \ \ \ \ \\ Quantity br 2 Wuo Smoke Detectors OK for selected panel! \ \.\\ \� • • • How many Total Enter powered Standby (aux Alarm Total Polling Standby Total External MULTI -POWER DEVICES Quantity externally? pwd Current (Aux) Potllrig Loop Loop Current Total Alarm Current Current Required \ \ \ \ \ \\ \ \ \ \ \ \\ N& \ \ \ \\ W. \ \ \ \ \ \ \�` \ \ \ \ \ \ \ \ \ )k \ \ \ \ \ \\ \ \ \ \ \ \ ` \ \ \ \ ` \ \ \ \ \ \l' \ \\P� \ \ \ \ \ \ \ \ \ \ \�& \\\\\\\\\\\\\\\\\\\ �P \ \& \ \ \ \ \ \ N \ \ \ \ \ \ \ —� \ \ \ \ \ \\ \\\\\\ l \\\\\\\ \\ \\ \ NN. \ \ \ \ \�\ \�& \ \ \ \ \ \ \ \ \� \\\\\\ '' \ ' \ ' \\\ \\ ��\ \\ \\\\\ \ \\\\\ ' ' , \ \ \ \ \ \ \ \�,� \, , , \ \ \ \ \ \� \\\\\ .1. \ \ \ \ \ \ \ \ \ \ \ \ \ \ \"C& • ■ , • How many Total Enter I powered Standby (aux Alarm Total Polling Standby Total External AUXILIARY POWERED DEVICES Quantity externally? pm) Current (Aux) Polling Loop Loop Current Total Alarm Current Current Required \�N 5140DLM Backup Dialer Module 1 0 5 15 ILI 5 15 0 �� • LED Active? \ . \\\ El LED Active? \ \. \ \ \\ ' \. o��? � \\ \� \\ WI How many Total Enter powered by Standby (aux Alarm Total Polling Standby Total External POLLING I:00P DEVICES Quantity 0297? pwr) Current (Aux) Polling Loop Loop Current Total Alarm Current Current Required N N 4190SN Two Zone SIM 3 0 & N\ N 2 6 x X s, X& \N X & N& NZ X N N N. N& N N N :N.. X& X N& \ N.4,.s\ N • .... ....;,:‘ \\N& N& N & N N& X iks, ,\ N '.\\. N.: N. & & N iii LED Active? s \ . N& .■%. • LED Active? • S' • LED Active? & N& N & & N.N!.',... & N& NI s „\ s „ \` N& & & & N ,.\ N& z`.. Ns, .,■,,„, N.`, Ns& N ,`.. .\ N..., & N N\ N • Ni:;‘‘\ N,_ X • LED Active? N N.'. • LED Active? N ..... N& N& N N& N • LED Active? & N N& N X. N . ,\ '... ''.., NN ‘N \N N N N& \ N N. N& N & How many Total Total Sounder 12V NOTIFICATION DEVICES ON Enter powered Standby (aux Alarm Total Polling Standby Current from Panel Total Sounder BELL OUTPUT #1 Quantity externally? pwr) Current (Aux) Polling Loop Loop Current Bell 91 Current (external) \ NS & 1 \ \ \\\\ How many Total Total Sounder 42V NOTIFICATION DEVICES ON Enter powered Standby (aux Alarm Total Polling Standby Current from Panel Total Sounder BELL OUTPUT #2 (IF USED) Quantity externally? pwr) Current (Aux) Polling Loop Loop Current Bell 92 Current (external) NZ \ \ \ \ \ \ •\,\\. \I Actual 12V AUX POWER AND BELL CIRCUIT Ohms per Alarm Current Resistance Voltage Drop WIRE RUN DATA Units Wire Gauge(AWG) 1000 ft Draw (mA) Run Length (twin leads) Voltage At EOL (Percent) Panel Aux Power Wire Run (twin lead) Feet I 7 ` Wire Gau I 7 0.00 0 0.00 12 00 0.00 Panel Bell 1 Wire Run (twin lead) Feet J' <Select Wire Gauge> I v 0.00 ,.. 0 0 00 12.00 0.00 . \ Panel Bell 2 Wire Run (twin lead) _Feet I V <Select Wire Gauge> I V I 0 00 0 0.00 12.00 0.00 • 0 1 CO N V O N 1 N A W N-. O t0 CO V T N A W N + 0 0 0 V O N A W N + V V 1 1 ,0 , 0>Z00 1 ti CD CD 3 ;" A m ° 0v ' c am ''. a D j Q 3 n m oN m CD CD mc' 3 3 0 c m oz . 1m-. c O rn 3 in v'otn Q - - N c z� � G) m • m< L.1 D • • > Activate Common Alarm Signal Indicator n f- - .- • • W Actuate Audible Alarm Signal . 0 1l " ° n =I 0 • • n Actuate Common Supervisory Signal Indicator a _ G7 ° • • • ! 0 A ctuate Audible Supervisory Signal - D m • • • • • • m Actuate Common Trouble Signal Indicator D - = 0 • r • • • • • • • " Actu ate Audible Common Trouble Signal • • O Actuate Alarm Indicator By Zone d ' .+ _ .. O r - D Actuate Signals: Extenor Bell 0 x • • 74 Actuate Signals Horn and Strobe Lights 0 r • • • • • r Display Change of Status o . m - • • • 3 Transmit Fire Alarm Signal to Supervising Station m Z • • z Transmit Supervisory Signal to Supervising Station o O • • • • 0 Transmit Trouble Signal to Supervising Station v -a N . N 0 -i . m 3 z m 0 U1 N C C -I ..i .7 -I c c a ii . r, 0 x x C) • O O N N . m m . . to Co 0 0 y ° ° v 3 -n W N N NN N N NN 1O OD V W O1 W N-� O 0 CO V 01 O1 A W N+ 0 CO CO V 01 N 4 W N + O Honeywell • VISTA -32FB • COMMERCIAL PARTITIONED FIRE AND ' ` •y' BURGLARY ALARM CONTROL PANEL_' • T' Now UL864 9th Edition Approved Designed to integrate seamlessly with CCTV, access control initiating devices, notification circuits, communication devices, and Honeywell's full range of fire and burglary components, keypads, RF receivers and relays are also supported. the new VISTA -32FB provides the ultimate protection of life The VISTA -32FB has been designed to mount quickly and property. The UL Listed commercial fire and burglary and easily. control panel supports up to two partitions and up to 32 zones /points using hardwired, wireless and V -Plex® addressable technologies. A diverse line of Honeywell FEATURES • Supports addressable V -Plex access • Automatic smoke detector sensitivity • False alarm reduction features: control points using VistaKey maintenance testing - Exit error logic (One to Four doors) - Exit delay reset • Commercial Wireless Fire and • Supports eight hardwired zones, Burglary - Cross zoning 24 V -Plex addressable points /zones, - Call waiting defeat • Notification Appliance Circuits (two): - Recent close report or 32 wireless points /zones - Programmable • Can control two separate areas - Individually silenceable • Supports commercial hardwired, (partitions) independently addressable V -Plex polling loop • Carbon monoxide (CO) zone support and wireless zones • Stores up to 512 events and can (Rev 5 and higher) accommodate 75 user codes • Listed to UL864 9th Edition (Rev 5 • Programmable on -board auxiliary and higher) • Easily programmed and maintained relay with newly upgraded Compass Downloader Software VISTA -32FB Honeywell COMMERCIAL PARTITIONED FIRE AND BURGLARY ALARM CONTROL PANEL ADDITIONAL FEATURES • Hardwired zones - Two -wire smoke detector • Up to four doors using VistaKey - Provides nine style B hardwired zone /group expansion module V -flex Access Control zones adds two or four zones • Stored events for one call retrieval - EOLR supervised for Fire and UL - Eight zone - Class A and B • Communication burglary installations extender module - Panel operation during download - Supports N.O. or N.C. sensors - Eight zone - Class B extender - Split/Dual Reporting module - Individually assignable to one of Applications eight partitions - One zone supervised contact - Up to 16 two wire smoke detectors monitor module The VISTA -32FB control is well suited for a variety of applications as an each on zone one and two (32 total) • UL Listed wireless expansion integrated fire and burglary control. polling - Supports up to 32 wireless zones/ • Patented addressable V -flex Some of the a lications supported p 9 pp pported are: loop technology points using 5881 ENHC or medical and professional buildings, - Supports up to 24 two -wire V -flex 5883H Receiver churches or synagogues, office zones /points - Supervised by control for buildings, schools, strip malls, - Global polling technology for check -in signals residences and factory or warehouse faster processing - Tamper protection for transmitters environments. - Supervised by panel - Individually assignable up to Installation - Individually assignable to partitions, eight partitions The VISTA -32FB alarm system has notification circuit (bell) output or - Supports wireless smoke detectors been designed to mount both quickly • aux relay and easily. It meets all applicable • Event reporting requirements for UL commercial fire - 4,000 ft. capability without the use • Local printer for access or and burglary installations. of shielded cable VISTA related event - Extender /Isolation bus modules • • • • • : Hone reH • _ SPECIFICATIONS __..__ __ ____. • _.._. Electrical Main Dialer Agency Listings • Primary power: 18VAC © 72VA • Line seize: Double Pole • FCC Part 15, Class B: FCC Part 68 ADEMCO No. 1451 • Ringer equiv.: 0.7B • UL864 /NFPA 72, Central Station and • Quiescent current draw: 300mA • Formats: ADEMCO Low Speed, Remote Station (Fire) • Backup battery: ADEMCO 4 +2 Express, ADEMCO • UL609 Local Mercantile 12VDC, 7AH min to 34.4AH max High Speed, ADEMCO Contact ID, Premises /Mercantile Safe & Vault - Lead acid battery (gel type) Sescoa and Radionics • • UL365 police station connected • Alarm power: 12VDC, 1.7A max for Cabinet dimensions burglar alarm • each notification (bell) circuit output • 14.5" H X 12.5" W X 3" D • UL610 Central Station • Aux. standby pwr: 12VDC. 1A max Environmental Burglar Alarm • Total power: 2.3A at 12VDC. .Storage temp: 14° F to 158° F • California State Fire Marshal • 3.4A at 24VDC from all sources (_1.02_C_to20_C) • EM • 24 hours with 1A standby load • Operating temp: 32° F to 122° F • CAN /ULC S304 - Central and Fusing • V (0° .0 to 50° C) Monitoring Station Burglar Alarm Unit •• Battery input. aux. and notification • Humidity: 85% RH • CAN /ULC S527 - Central Unit for (bell) circuit outputs are protected Fire Alarm Systems • EMI: Meets or exceeds the using PTC circuit protectors. All following requirements: • outputs are power limited. g q CAN /ULC S303 - Local Burglar - FCC Part 15, Class B Device Alarm Unit • - FCC Part 68 • CAN /ULC S525 - Audible Signal - IEC EMC Directive . Appliances • • • • • • • • VISTA -32FB COMMERCIAL PARTITIONED FIRE AND BURGLARY ALARM CONTROL PANEL COMPATIBLE DEVICES Auxiliary Devices • 4190WH AlarmNet Communicators • 4204 - Relay Module, • 4193SN Two Zone Serial • 7545i -ENT - Internet/Intranet four form C contacts Interface Module Communicator • 4204CF - Two supervised • 4208U Loop Expansion Module • 7845GSM - Digital Cellular output circuits - eight zones Communicator • 5140DLM - Supervised Dialer • 4208SNF Eight Zone /2 Class N6 • 7845i -GSM - Internet and Digital • 5881 ENHC - RF Receiver Class B Expander Module Cellular Communicator • 5883H - RF Receiver • 4293SN One Zone Serial Access Control • 6160CR -2 - Red Alpha Keypad Interface Module • VistaKey V-Plex (addressable) • 6160 - Burglary Keypad • 4297 Isolator /Extender Module Access Control • 6220S - System printer used with • V -Plex VSI Isolator Module • VistaKey SK Starter Kit 4100SM serial module V -Plex Smoke Detectors • VistaKey -EX Expansion Kit Two -Wire Smoke Detectors • 5193SD Commercial Wireless Devices Conventional • 5193SDT • 5808W3 - Photoelectronic • System Sensor V -Plex Passive Infrared Detectors Smoke /Heat Detector • ESL • DSC • 998MX • 5806W3 - Photoelectric Smoke • IS2500SN Detector Horn /Strobes • DT7500SN • 5809 - Wireless Heat Detector • System Sensor • QUEST2260SN • 5817CB - Wireless • Wheelock Commercial Transmitter V -Plex Contacts • Gentex • 4194WH • 5869 - Hold -Up Transmitter Manual Pull Stations • 4939SN-WH • 5881 ENHC - RF Receiver • 5140MPS -1 • 4944SN -WH • 5883H - RF Receiver • 5140MPS -2 • 4959SN V -Plex (Addressable) Devices V -Plex Glassbreak Detectors • 4101SN Relay Zone Module • FG1625SN • 4190SN Remote Point Module - two zones Product specifications subject to change. ORDERING VISTA -32FB Commercial Fire and Partitioned Burglary Alarm Platform V32FB -9 UL864 Rev 9 Version (Rev 5 and higher) Automation and Control Solutions • Honeywell Security & Communications Honeywell 2 Corporate Center Dr. Suite 100 Melville, NY 11747 1.800.467.5875 LMST32F6 /U Octobor 2010 www.honeywell.com © 2010 Ho,iaywetl International Inc. • 6 ' 1 60C _ z m r �Z t� ti �iaf}il� y �Ti�t> 5 COMMERCIAL FIRE ALPHA KEYPAD • gait ; h '; uxle : ' ice;: o � , = h r " r� x k The 6160CR is an addressable remote keypad intended only when a key is depressed'. or when the system is in for use in commercial fire applications with Honeywell's alarm or trouble condition. control platforms. The keys are continuously backlit for • Note On some platforms, the LCD may he programmed to remain on at at convenience and easy visibility. The LCD display is backlit times (see panel Instructions for details). FEATURES • Four programmable • Four LEDs • • Large easy -to -read display function keys - Armed • • Red removable door • Built -in sounder -Ready - Trouble • Physical - Supervisory 5.250" W x 7.437" H x 1.312" D SPECIFICATIONS • Display - Sounder Compatibility • Alphanumeric, 32- character • High - quality speaker • Supports Control Platforms (2 lines x 16 characters) Electrical - VISTA -32FB Rev. 3 and higher LCD back light LEDs: - VISTA -128FB Rev. 4 and higher Armed (red) • 45mA standby 150mA in alarm - VISTA- 128FBP Ready (green) (sounder, back light and LED on) - VISTA- 250FBP *Trouble (yellow) - V128F8P -24 Wiring Table (All keypads) 'Supervisory (yellow) - V250FBP -24 Dl "Data IN" to control panel from keypad See control anel's instructions for - UUCUL Listed for Residential and Commercial Fire p Ground ( -aux. Power) and Burg installations. To be employed with specific applications regarding + +12VDC ( +aux. Power) manufacturer's listed control units as indicated In Trouble and Supervisory LEDs. DO Data OUT" from control pane' tokeypad the installation instructions. ORDERING 6160CR Commercial Fire Alpha Keypad Automation and Control Solutions Honeywell Security & Communications � � ® ����� 2 Corporate Center Dr. Suite 100 y P.O. Box 9040 Melville, NY 11747 u'stsocav • - -- -- October 2008 - - - - - www.honeywell.com ID 2008 Honeywell International Inc • • BG -12 Series DF- 52004:A • F-050 Manual Fire Alarm Pull Stations Fl1'e.uTe''A'l.a1'I'Y1S by Honeywell F Addre General The Fire•Lite BG -12 Series is a cost - effective, feature - packed - ^ - series of non -coded manual fire alarm pull stations. It was , designed to meet multiple applications with the Installer and • end -user in mind. The BG -12 Series features a variety of mod- els including single- and dual- action versions. - The BG -12 Series provides Fire•Lite Alarm Control Panels • (FACPs), as well as other manufacturers' controls, with a man- PUSH IN ual alarm initiating input signal. Its innovative design, durable construction, and multiple mounting options make the BG -12 [ PULL DOWN • Series simple to install, maintain, and operate. • 1 Features • Aesthetically pleasing, highly visible design and color. • Attractive contoured shape and light textured finish. • Meets ADA 5 lb. maximum pull- force. • Meets UL 38, Standard for Manually Actuated Signaling Boxes. Fire -LITe° ) • Easily operated(single• or dual - action), yet designed to pre- ' r3 a vent false alarms when bumped, shaken, or jarred. - - - -- • PUSH IN /PULL DOWN handle latches in the down position to clearly indicate the station has been operated. Construction • The word "ACTIVATED" appears on top of the handle in bright yellow, further indicating operation of the station. Cover, backplate and operation handle are all molded of • Operation handle features white arrows showing basic opera- durable atures rbonate material. Cover features lion direction for non - English- speaking persons. white lettering and trim. • Braille text included on finger -hold area of operation handle • Red color matches System Sensor's popular SpectrAlerle and across top of handle. Advance horn /strobe series. • Multiple hex- and key -lock models available. • U.S. patent pending hex -lock needs only a quarter -turn to Operation lock /unlock. The BG -12 manual pull stations provide a textured finger -hold • Station can be opened for inspection and maintenance with- area that includes Braille text. In addition to PUSH IN and PULL out initiating an alarm. DOWN text, there are arrows indicating how to operate the sta- • Product ID label viewable by simply opening the cover; label lion, provided for non - English-speaking people. is made of a durable long -life material. Pushing in and then pulling down on the handle activates the • The words "NORMAL" and "ACTIVATED° are molded into the normally-open alarm switch. Once latched in the down position, plastic adjacent to the alarm switch (located inside). the word "ACTIVATED" appears at the top in bright yellow, with a • Four- position terminal strip molded into backplate. portion of handle protruding at the bottom as a visible flag. • Terminal strip includes Phillips combination -head captive 8/32 Resetting'the station is simple: insert the key, twist one quarter- screws for easy connection to Initiating Device Circuit (IDC). turn, then open the station's front cover, causing the spring- loaded operation handle to return to its original position. The • Terminal screws backed out at factory and shipped ready to accept field wiring (up to 12 AWG /3.1 mm2). alarm switch can then be reset to its normal (non - alarm) position manually (by hand) or by closing the station's front cover, which • Terminal numbers are molded into the backplate, eliminating automatically resets the switch. the need for labels. • Switch ntacts are normally open. • Can be surface- mounted (with SB -10 or SB -I /0) or semi - flush mounted. Semi -flush mount to a standard single -gang, double -gang, or 4° (10.16 cm) square electrical box. • Backplate is large enough to overlap a single -gang backbox cutout by 1/2" (1.27 cm). • Optional trim ring (BG- 12TR). • BG-12LSP). • Designed to replace the Fire•Lite legacy BG -10 Series. • Models packaged in attractive, clear plastic (PVC), clam- . shell-style, Point -of- Purchase packages. Packaging includes a cutaway dust/paint cover in shape of pull station. DF- 52004:A • 8/13/2007 — Page 1 of 2 • • • • • Specifications BG- 12LOB: Same as BG -12L with "outdoor use listing. - PHYSICAL SPECIFICATIONS: ' Includes outdoor listed backbox,'and sealing gasket. BG -12LO Same as BG -12L. with "outdoor use listing. Does not Include backbox. pull station SB -1/0 ____ _ SB -10 BG 121 ;A: - Same as :12L with auxiliary contacts. Height 5.5 inches 5.601 inches 5.5 inches BG- 12LPS: Dual-action pull station with pre - signal option. (13.97 Cm) (14.23 cm) (13.97 cm) Width 4.121 inches 4.222 inches 4.121 inches BG- 121_P Same as BG -12LPS with English /Spanish (FIRE/ (10.47 cm) (10.72 cm) . (10.47 cm) FUEGO) labeling. Depth 1.39 inches 1.439 Inches 1.375 inches SB -10: Indoor use backbox. SB - (3.53 cm) (3.66 cm) ' (3.49 cm) I /O Indoor /outdoor backbox. 52004dim.thl BG- 121'R: Optional trim ring for semi -flush mounting. ELECTRICAL SPECIFICAT IONS: • Keylock: Switch contact ratings: gold - plated; rating 0.25 A @ 30 VAC or 17007: Hex lock, 9/64 ". Comes with -Pull Station. VDC. • En /Architectimal • Specifications . Manual Fire Alarm Stations shall be non -code, with a key- or • hex - operated reset lock in order that they may be tested,.and so designed that after actual Emergency Operation, they cannot be • restored to normal except by use of a key•or hex. An operated station shall. automatically condition itself so as•.to be visually - • detected as activated. Manual stations shall be constructed of red colored LEXAN (or polycarbonate equivalent) with clearly visible operating instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches -(2.54 cm) or larger. Stations, shall be suitable- for surface mounting on matching backbox SB -10 or SB -I /O; or semi -flush mounting on a standard single -gang, double :gang, or • • 4" (10.16 cm) square electrical box, and shall be Installed within t • he limits defined by the Americans with Disabilities Act (ADA) or • • per national /local requirements. Manual Stations shall be Under- writers Laboratories listed. - NOTE: The words FIRE/FUEGO "on the BG -12LSP shall a • on the front of the station in white letters, approximately .3/4" • (1.905 cm) high. - i • Agency Listings and Approvals • The listings and approvals below apply to the BG -12 Series pull stations.. In Some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • • C(UL)US: 5711 - - • - • FM Approved ' • CSFM: 7150. 0075:184 • MEA: 67 -02 -E - Product Line Information BG -12S: Single- action pull station with pigtail connections, hex • lock. . BG -12SL: Same as BG•12 with key lock. BG -12: Dual- action pull station with SPST N/O switch, screw terminal connections, hex lock. BG - 12L: Same as BG - with key lock. Flre•Ute® Alarms. SpectrAlert® Advance, and System Sensor® are reg- BG - 12LSP: Same as BG - 12L with English/Spanish (FIRE/ istered trademarks of Honeywell International Inc. @2006 by Honeywell Inter - FUEGO) labeling. national Inc. `All rights reserved. Unauthorized use of this document is strictly prohibited. • 14a ® T his document Is not Intended to be used for installation purposes. , III 9001 We try to keep our product information up -to -date and accurate. •••.•'— CERTIFIED We cannot cover all specific applications or anticipate all requirements. ENllfaERINI9 MANIMAt18NNB • All specifications are subject to change without notice. QUALITY SYSTEMS - For more Information, contact Fire•Llte Alarms. Phone: (800) 627.3473. FAX: (877) 699-4105. Made In the U:S. A. www.firelite.com Page 2 of 2 — DF- 52004:A • 8/13/2007 • • • • SENSOR' 4 : ,r� A. ms s..- ' i.;., ' Ji:;_� 1 `";4 j Photoelectric N { Smoke Detectors , J+l �U 1 r, J� , t 1 P , System Sensor's i series smoke detectors represent significant advancement in conventional detection. ' `' ` "' ' 3 The P family is founded on three principles: installation T4 ease, intelligence, and instant inspection. • Features Installation ease. The i line redefines installation ease with its • •Plug-in detector line, mounting base Included plug-in design.This allows an installer to pre wire the bases included • Large wire entry port with the heads.The large wire entry port and in -line terminals provide ample room for neatly routing the wiring inside the base. • In -line terminals with SEMS screws • The base accommodates a variety of back box mounting methods, • Mounts to octagonal and single -gang backboxes, 4- square as well as direct mounting with drywall anchors. To complete the backboxes, or direct to ceiling installation, P heads plug in to the base with a simple Stop -Drop 'N • Stop -Drop 'N Lock attachment to base Lock` action. • Removable detector cover and chamber Intelligence. l detectors offer a number of intelligent features • Built In remote maintenance signaling to simplify testing and maintenance. Drift compensation and • Drift compensation and smoothing algorithms smoothing algorithms are standard with the P line to minimize nuisance alarms. Two -wire i detectors needing cleaning can • Simplified sensitivity measurement generate a remote maintenance signal, when connected to the • Wide angle, dual color LED Indication 2W -MOD2 loop test/maintenance module, or to a panel equipped • Loop testing via EZ Walk feature with the i protocol. This signal Is Indicated by LEDs locatedat the module and the panel. The SENS -RDR, a wireless device, displays the • Built -In test switch sensitivityof P detectors In terms of percent per- foot- obscuration. Instant inspection. The i series provides wide -angle red and green LED Indicators for Instant inspection of the detector's condition: normal standby, out -of- sensitivity, alarm, or freeze trouble. When connected to the 2W -MOD2 loop test/maintenance module or a panel with the i protocol, the EZ Walk loop test feature is available on two -wire i detectors. This feature verifies the initiating loop wiring by providing LED status indication at each detector. Agency Listings T ® MEA MSFM LISTED APPROVED I approved approved 5911 3011446 7272- 1209:210 290-01 -E 2093 • • • . (6 Smoke Detector Specifications • • Architectural /Engineering Specifications_ _. _:__ _ • , Smoke detector shall be a System Sensor P Series model number , listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems. The detector -shall be a photoelectric type (Model 2W -B; 4W -B) or a combination photoele (Model 2WT-B, 4WT -B) with thermal sensor rated at 135 °F (57.2 °C). The detector shall Include a mounting base for mounting to 31/2-inch and4-inch octagonal, single gang, and 4 -Inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws.The detector shall allow pre- wiring of the base and the head shall be a plug -In type.The detector shall have a nominal sensitivity of 2.5 percent - per -foot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting Its sensitivity by means of drift compensation and smoothing algorithms. The detector shall provide dual color LED Indication which blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WT-B, 4WT-B) conditions. When used In conjunction with the 2W MOD2 module, 2 -wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel, and shall provide a loop testing capability to verify the circuit without testing each detector Individually. Electrical Specifications . Operating Voltage Nominal. 12/24V non- polarized Minimum: 8.5V • Maximum: 35V • Maximum Ripple Voltage 30% peak to peak of applied voltage Standby Current 2 -wire: 50 pA maximum average; 4 -wire: 50 pA maximum average Maximum Alarm Current 2 -wire: 130 mA limited by control panel; 4 -wire: 20 mA @12V, 23mA @ 24V Peak Standby Current . 2 -wire: 100 NA; 4 -wire: n/a , Alarm Contact Ratings 2 -wire: n /a; 4 -wire: 05 A @ 30V AC/DC • Physical Specifications .. • . • Dimensions (Including base) 5.3 inches (127 mm) diameter; 2.0 inches (51 mm) height • Weight • • 6.3 oz. (178 grams) Operating Temperature Range . 2W -B and 4W -B: 32 °F -120 °F (0 °C- 49 °C); 2WT-B and 4WT-B: 32 °F -100 °F (0C-37.8°C) Operating Humidity Range 0 to 95% RH non - condensing . ' Thermal Sensor 135 °F (57.2 °C) fixed - Freeze Trouble - 2WT B and 4WT-B only-419F (5 °C) Sensitivity: 2596/ft. nominal Input Terminals 14-22 AWG • • • Mounting 315 -Inch octagonal back box 4 -Inch octagonal back box Single gang back box • 4 -Inch square back box with a plaster ring • Direct mount to ceiling LED IVlodes' : :; . P ower Up Sequence for LED Indicatiori LED Mode Green LED • - - Red LED .. Condition Duration Power up Blink every 10 seconds. Blink every 10 seconds initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off. • Out of sensitivity off . Blink every 5 seconds Freeze trouble off . Blink every 10 seconds , Alarm - off Solid • Ordering Infor . ;Wider.... _. Thermal • Wirin Alarm Current • 2W -B No 2 -wire -130 mA max. limited by control panel 2WT -B Yes 2 -wire - 130 mA max. limited by control panel 4W -B No ' . 4 -wire 20 mA @ 12V, 23mA @ 24V 4WT-B Yes 4 -wire 20 mA @ 12V, 23mA @ 24V Accessories 2W -MOD2 2 -wire loop test / maintenance module RT Removal / replacement tool SENS -RDR Sensitivity reader A77 -AB2 Retrofit adapter bracket, 6.6 in. (16.76cm) diameter • --- SYSTEM EA.'s 3825 Ohio Avenue • St. Charles, IL 60174 oma sn1� Serum. - ` rhomm%Deofiutau wgeu to lunge wahart rota Km rystam°ruacan iu 0V Phone: 800•SENSOR2• Fax 630- 377 - 6495 currn1 awormal hcbArni ihe Lite,' version d Olt MIA w01. A05-0718-006. 7/1:6• /1676 • • l . I Installation Instructions The 4193SN is a serialized two -zone expander used to connect alarm sensing oneywell devices to controls that support serial number polling loop devices (e.g 9 i • Vista -50P, Vista -128BP and Vista- 250FBP). The ADEMCO 4193SN can be configured as one supervised zone (10K EOLR) and one unsupervised zone (normally closed devices only). ADEMCO 4 1 9 • Consult the control panel installation instructions for programming information. V -Fle Two Zone Expander I Electrical Specifications For connecting alarm sensing devices and switches to Voltage: 8 -12VDC (as supplied from the Honeywell ADEMCO V -Flex polling loop systems V-Plex polling loop). ywell Security Control Panel Current 1.5mA Quantity: 1 ea.' ' Max. Line Impedance: 300 ohms i Requires control panel with SERIAL NUMBER device capability . (e.g.,. Vista -50P,- .Vista- 128BP, Vista- 250FBP )-- -- - • ; WHITE (LOOP 1) SUPERVISED EOLR 10K .. - -. .. ..... - -•- - -- - •- -- - - - --- .... -. - . 1 (CLASS B) HED ( +) Consult control panel instructions for compatibility YELLOW (LOOP 1) UNSUPERVISED POWNG ' LOOP GREEN (LOOP 2) UNSUPERVISED ® UL BLACK ( —) BLACK (COMMON) s LISTED WIRING DIAGRAM - S789 For Fire Applications: The 4193SN must be mounted inside the control panel or inside a UL- Listed junction box. Loop 1 (supervised) may be used in the supervised configuration for Fire. Loop 2 may not be used for fire. Use Honeywell End -Of -Line resistor model number = Q U A N T I Y : ONE EOL100, 10K ohms, on Loop 1. Loop 1 of this module can be used with four wire smoke detectors, heat detectors and pull stations. Polling loop is • Class B, Style 3. - For UL Burglary Applications: 1015 AM 4193SN If using Loop 2 (unsupervised) zone of the ADEMCO 4193SN, the unit must be mounted within 3 feet of the alarm initiating device, with no barriers. Notes: III JI IllIlIllIllIllIl 3 1. Fol itedr dry indoor use only. 1111111 III 11 IIII I II I I I Il 111 Do not install in air- handling spaces. 81410 N7644V4 2/09 Rev. A N7644V4 2/09 Rev. A • [Page Too Large for OCR Processing]