Loading...
Specifications • FRc3 oI2 -BSc 9530 OaAir., 5c, IA 410 t iic� Fire Suppression & Building Products iviAY 2 QS 20V Technical Services 800 - 381 -93121 +1- 401 - 781 -8220 7 ° ; � ' 7 ANC- `-' 1 •j www.tyco- fire.com Series TY -FRB — 2.8, 4.2, 5.6, and 8.0 K- Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage G eneral Corrosion- resistant coatings, where applicable, are utilized to extend the :� , „• Descri tion life of copper alloy sprinklers beyond ;R =: ��'�7`33 p that which would otherwise be obtained "_ s The TYCO Series TY -FRB, 2.8, 4.2, 5.6, when exposed to corrosive atmo- i•i- 1,, _ • {1 .3 :.,';.ii and 8.0 K- factor, Upright and Pendent spheres. Although corrosion- resistant l Y rsp.. i Sprinklers described in this data sheet coated sprinklers have passed the , J' ( ` are quick response, standard coverage, standard corrosion tests of the appli- I 1 l�F', decorative 3 mm glass bulb -type spray cable approval agencies, the testing is f ,� -1 :. sprinklers designed for use in light or not representative of all possible cor- tit '°' , r ordinary hazard, commercial occupan- rosive atmospheres. Consequently, . • cies such as banks, hotels, and shop- it is recommended that the end user -- ping malls. be consulted with respect to the suit- ' ability of these coatings for any given The recessed version of the Series TY- corrosive environment. The effects of FRB Pendent Sprinkler, where applica- ambient temperature, concentration of ble, is intended for use in areas with a chemicals, and gas /chemical velocity, finished ceiling. This recessed pendent should be considered, as a minimum, .� _ sprinkler uses one of the following, along with the corrosive nature of the • • A two -piece Style 10 (1/2 inch NPT) chemical to which the sprinklers will be i n "� — or Style 40 (3/4 inch NPT) Recessed exposed. . . .: ti Escutcheon with 1/2 inch (12,7 mm) of An intermediate level of the Series TY- " ^1` recessed adjustment or up to 3/4 inch FRB Pendent Sprinklers is detailed ` � (19,1 mm) of total adjustment from the in Technical Data Sheet TFP356, and =' flush pendent position, or a Sprinkler Guards are detailed in Tech- _ . • A two -piece Style 20 (1/2 inch NPT) nical Data Sheet TFP780. or Style 30 (3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of NOTICE recessed adjustment or up to 1/2 inch The Series TY Concealed Pendent Model /Sprinkler (12,7 mm) of total adjustment from the Sprinklers described herein must be flush pendent position. installed and maintained in compliance Identification The adjustment provided by the with this document and with the appli- Recessed Escutcheon reduces the cable standards of the National Fire Number (SIN) accuracy to which the fixed pipe drops Protection Association, in addition to to the sprinklers must be cut. the standards of any authorities having TY1131: Upright 2.8K, 1/2" NPT jurisdiction. Failure to do so may impair TY1231: Pendent 2.8K, 1/2" NPT the performance of these devices. TY2131: Upright 4.2K, 1/2" NPT Owners are responsible for maintaining TY2231: Pendent 4.2K, 1/2 " NPT their fire protection system and devices TY3131: Upright 5.6K, 1/2 " NPT in proper operating condition. The TY3231: Pendent 5.6K, 1/2" NPT IMPORTANT installing contractor or sprinkler manu- TY4131: Upright 8.0K, 3/4" NPT Always refer to Technical Data facturer should be contacted with any TY4231: Pendent 8.0K, 3/4" NPT Sheet TFP700 for the "INSTALLER questions. TY4831: Upright* 8.0K, 1/2" NPT WARNING" that provides cautions TY4931: Pendent* 8.0K, 1/2" NPT with respect to handling and installation of sprinkler systems and components. Improper handling and . installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it • to operate prematurely. 'Eastern Hemisphere Sales Only Page 1 of 10 JULY 2010 TFP171 • T . . FP171 • • Page 2of10 • - —7/16".(11,1 mm) - — ESCUTCHEON — -'- - STYLE10 "or20 - - - - -- - - - • * NOMINAL • PLATE SEATING RECESSED • SSU MAKE -IN 1/2" • SURFACE ESCUTCHEON DEFLECTOR NPT . • 6 . ' \ • _.1_ j I • 5 !El ( 7/16° � rr __,MI 4 li NOMINAL 111 m6m ) 2 -1/4° i1�l!',� I IL (57,2 mm) � L- 2 MAKE -IN • If (55.6 16" ! ref 1- 9/16" �� � 3 23/16" WRENCH (39,7 mm) 1 FLATS III i , . . sue¢ -- 7 1/2 NPT SSP DEFLECTOR -•— 2 -7 /S" (73,0 mm) DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT 1 - Frame 3 - ASe�aei bl 4 -Bulb 6 - Deflector • • Temperature rating is indicated on deflector or adjacent to y 5 - Compression, orifice seat on frame. • 2 -Button Screw Bushing • • FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY1131) AND PENDENT (TY1231) SPRINKLERS 2.8 K- FACTOR, 1/2 INCH NPT • . • • 7/16" (11,1 mm) ESCUTCHEON STYLE 10 or 20 * NOMINAL PLATE SEATING RECESSED • SSU MAKE -IN 1/2° SURFACE ESCUTCHEON DEFLECTOR l NPT . 6* _L — ; ;i,fiit *try.;.,. /i./ ' T ._..�o • —° 4; °C • • 5 o =• • 7/16.. rr (11,1 mm) 2 • 3/16" 1 �1'' � � 4 ; I NOMINAL ., _ 111 (55,6 mm) � �� L� MAKE-IN g ." 1 • 2 2-3/16" 11111.11 1 -1/2" to 3 . (55,6 mm)• . t WRENCH I 138,1•mm) FLATS III 1/2" NPT SSP DEFLECTOR --•— 2 -7/8" (73,0 mm) DIA. —•-- • CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT 1 - Frame 3 - Sealing 4 - Bulb • 6 - Deflector • Temperature rating is indicated on deflector or ad Compression p g adjacent to Assembly 5 - Com I 2 - Button p orifice seat on frame. • Screw • FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K- FACTOR, 1/2 INCH NPT • • • • TFP171 _ Page 3 of 10 • -• - - - 7/16" (11;1 mm) - -- ESCUTCHEON - - - -- -- STYLE 10 dr 20 * NOMINAL PLATE SEATING RECESSED DEFLECTOR MAKE NPT SURFACE ESCUTCHEON • 6* 5 !Eo 7/16" I _ _ (11,1 mm) 2 -3/16" '�� 4 ; I NOMINAL i mm) E I f 2/16 (55mm) 1 WRENCH (38,1 mm) i4 1 �� FLATS 1/2" NPT SSP DEFLECTOR * — 2 -7/8" (73,0 mm) DIA. - . CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT 1 -Frame . .3 - Sealing 4 - Bulb 6 - Deflector • P rating is Tem erature ratin indicated on deflector or adjacent to • Assembly 5 - Compression . I 2 - Button P orifice seat on frame. Screw . • • • FIGURE3 QUICK RESPONSE SERIES TY—FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K— FACTOR, 1/2 INCH NPT ' • 1/2" (12,7 mm) ESCUTCHEON STYLE 30 or 40 SSU * NOMINAL 3/4 PLATE SEATING RECESSED MAKE -IN SURFACE ESCUTCHEON DEFLECTOR I NPT 6* L— Iii rr,'TTI'FT - Tr, • ' 5 ig! 1/2" � � — I (12,7 mm) + NiswP 2 -5/16" f 4 ' I NOMINAL �7 mm) • p1� 2 1 L U JI m o 2 1- 9/16" 3 (57,2 mm /4 ) • j �� . (39,7 mm) • 1 111 � of 1 t 3/4" NPT SSP DEFLECTOR * 2 -7/8" (73,0 mm) DIA. -- CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT 1 - Frame 3 Sealing As bl 4 - Bulb 6 - Deflector • Temperature rating is indicated on deflector or adjacent to Assembly 5 - Compression orifice seat on frame. 2 - Button Screw FIGURE 4 QUICK RESPONSE SERIES TY—FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS . 8.0 K— FACTOR, 3/4 INCH NPT • • • • . • • TFP171 , Page 4 of 10 7/16" (11,1 mm) - -- . — - SSU * -. - NOMINAL. -.. — • ' DEFLECTOR MAKE -IN 1/2" NPT 5 ° 1 7/16" ° li 2 -1/4" 4 N �`. 6* eEI N1,1 NAL 1111 rii �,�� mm) I (57,2 mm) OMINAL — } MAKE -IN 2 ,A V¢ 2-3/16° I � I I 1 -9/16" 3 (55,6 mm + — (39 WRENCH ,7 mm) l _�_ FLATS II 1 CROSS 1/2 NPT DEFLECTOR • SECTION UPRIGHT • PENDENT 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector • Temperature rating is indicated on deflector or adjacent to Assembly 5 - Compression - orifice seat on frame. i • 2 - Button Screw • • FIGURE 5 . • QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K- FACTOR, 1/2 INCH NPT Technical Operation • inch (1,6 mm) for the 135 °F /57 °C and 3/32 inch (2,4 mm) for the 286 °F /141 °C Data The glass Bulb contains a fluid that temperature ratings. • expands when exposed to heat. When Obtain a leak -tight 1/2 inch NPT sprin- Approvals the rated temperature is reached, the kler joint by applying a minimum to UL and C -UL Listed fluid expands sufficiently to shatter the maximum torque of 7 to 14 ft.lbs. (9,5 FM, LPCB, and NYC Approved glass Bulb, allowing the sprinkler to to 19,0 Nm). Higher levels of torque Refer to Table A and B for complete activate and water to flow. can distort the sprinkler Inlet with con - approval information including sequent leakage or impairment of the corrosion resistant status. Design. sprinkler. • Maximum Working Pressure _ Do not attempt to compensate for Refer to Table C. Cr9fePia insufficient adjustment in the Escutch- The TYCO Series TY - FRB Pendent eon Plate by under- or over tightening Discharge Coefficient the sprinkler..Re- adjust the position of K = 2.8 GPM /psi (40,3 LPM /bars /2 and Upright Sprinklers are intended the sprinkler fitting to suit. • K =4.2 GPM /psit/ (60,5 LPM /bart�2 for fire protection systems designed in • ) The Series TY -FRB Pendent and accordance with the standard installa- • K =5.6 GPM /psi (80,6 LPM /bar1 /2) tion rules recognized by the applicable Upright Sprinklers must be installed K =8.0 GPM /psi" (115,2 LPM /bar1"2) Listing or Approval agency (such as, UL in accordance with the following Listing is based on the requirements of Temperature Rating instructions. Refer to Table A and B. NFPA 13, and FM Approval is based on 1. Install Pendent sprinklers in the the requirements of FM's Loss Preven- pendent position. Install upright Finishes tion Data Sheets). Only the Style 10, sprinklers in the upright position. Sprinkler: Refer to Table A and B. 20, 30, or 40 Recessed Escutcheon, as 2. With pipe- thread sealant applied to Recessed Escutcheon: White Coated, applicable, is to be used for recessed the i e threads, hand-tighten the Chrome Plated, or Brass Plated. pendent installations. sprinkler into the sprinkler fitting.. Physical Characteristics Installation 3. Tighten the sprinkler into the sprin- Frame Bronze kler fitting using only the W-Type 6 Button Brass /Copper The TYCO Series TY -FRB Sprinklers Sprinkler Wrench (Figure 14). With Sealing Assembly Beryllium must be installed in accordance with reference to Figures 1 through • Nickel w/Teflont the following instructions. 5, apply the W-Type 6 Sprinkler Bulb Glass Wrench to the sprinkler wrench Compression Screw Bronze • = NO T ICE flats. Deflector Copper /Bronze . Bushing (K =2.8) Bronze Do not install any bulb -type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- • ble should be present. The diameter t Registered Trademark of Dupont of the air bubble is approximately 1/16 • • • TFP171 Page 5 of 10 SPRINKLER FINISH (See Note 5) K TYPE_ TEMPERATURE BULB LIQUID NATURAL CHROME WHITE * ** FACTOR COLOR BRASS PLATED POLYESTER 135 °F /57 °C Orange (ENDEN) 155 °F /68 °C Red and 175 °F /79 °C Yellow 1, 2, 3, 4 UPRIGHT (TY1131) 200 °F /93 °C Green 286 °F /141 °C Blue 135 ° F /57 °C Orange 2.8 RECESSED 155 °F /68 °C Red 1/2" NPT PENDENT (TY1231)* 175 °F /79 °C Yellow Figure 6 200"F/93°C Green 1,2,4 135 °F /57 °C Orange RECESSED •PENDENT 155F/68°C • Red • (TY1231) ** 175F/79°C Yellow Figure 7 200 °F /93 °C Green 1 °F /57 °C Orange PENDENT 155 °F /68 °C . Red • and 175"F/79°C Yellow UPRIGHT (TY2131) 200"F/93°C Green 286"F/141°C Blue 135 °F /57 °C Orange 4.2 RECESSED 1 55 F /68 1/2" ° C - Red 1, 2 NPT PENDENT ° (TY2231)* 175"F/79°C Yellow • • • Figure 8 200 °F /93 °C Green 135 "F /57 °C Orange • RECESSED PENDENT 155 °F /68 °C Red • • (TY2231) ** 175F/79°C Yellow - Figure 9 • 200 °F /93 °C Green NOTES:. 1. Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. • 2. Listed by Underwriters Laboratories, Inc:, for use in Canada (C -UL) as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. 4. Approved by the City of New York under MEA 354 -01 -E. 5. Where Polyester Coated Sprinklers are noted to be UL and C -UL Listed, the sprinklers are UL and C -UL Listed as Corrosion- Resistant Sprinklers. Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. " Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS FOR 2.8 AND 4.2 K- FACTOR SPRINKLERS • • • • TFP171 Page 6 of 10 • SPRINKLER FINISH (See Note 8) • K TYPE TEMPERATURE BULB LIQUID NATURAL CHROME WHITE * ** LEAD FACTOR COLOR BRASS PLATED POLYESTER COATED • 135 °F /57 °C Orange PENDENT 155 °F /68 °C Red (TY3231) and 175 °F /79 °C Yellow 1, 2, 3, 4, 5, 6, 7 1, 2, 3, 5 UPRIGHT 200 °F /93 °C Green (TY3131) 286 °F /141 °C Blue • 135F/57°C Orange RECESSED 155 °F /68 °C Red 5.6 PENDENT 175 °F /79 °C Yellow 1, 2, 4, 5 N/A 1/2" NPT (TY3231)' • Figure 10 200 °F /93 °C Green 286 °F /141 °C Blue 135 °F /57 °C . Orange RECESSED 155 °F /68 °C . Red • PENDENT (TY3231) 175F/79°C Yellow 1, 2, 3, 4, 5 N/A Figure 11 200 °F /93 °C • Green • 286 °F /141 °C" Blue • 135F/57°C • Orange • • PENDENT • (TY4231) 155 °F /68 °C Red and . 175 °F /79 °C Yellow. 1, 2, 3, 4, 5, 6, 7 1, 2, 5 UPRIGHT 200 °F /93 °C - Green • (TY4131) 286 °F /141 °C Blue . 135 °F /57 °C Orange . RECESSED 155 °F /68 °C Red 8.0 PENDENT 175Ff79°C Yellow 1, 2, 5 N/A 3/4" NPT • (TY4231)• Figure 12 200 °F /93 °C Green 286 °F /141 °C Blue . 135 °F /57 °C Orange RECESSED 155 °F /68 °C • Red . • PENDENT 175 °F /79 °C Yellow 1, 2, 3, 5 N/A . (TY4231)" - • Figure 13 200 °F /93 °C Green • . 286 °F /141 °C Blue . • • . 135 °F /57 °C Orange • • PENDENT • • 155 °F /68 °C • Red ` • 8.0 (TY4931) • 1/2" NPT and , • 175F/79°C Yellow 1, 2, 4, 5, 6 1, 2, 5 UPRIGHT 200 °F /93 °C Green • (TY4831) 286 °F /141 °C Blue NOTES: 1. Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. 2. Listed by Underwriters'Laboratories, Inc., for use in Canada (C -UL) as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers. However, LPCB does not rate the thermal sensitivity of recessed sprinklers. 5. Approved by the City of New York under MEA 354 -01 -E. 6. VdS Approved (For details, contact Tyco Fire Suppression & Building Products, Enschede, Netherlands, Tel. 31 -53- 428- 4444/Fax 31 -53- 428- 3377.) 7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. 8. Where Polyester Coated and Lead - Coated Sprinklers are noted to be UL and C -UL Listed, the sprinklers are UL and C -UL Listed as Corrosion- Resistant Sprinklers. Where Lead - Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion- Resistant Sprinklers. Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. "' Frame and Deflector only. Listings and approvals apply to color (Special Order). N /A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8.0 K- FACTOR SPRINKLERS • • TFP171 Page 7of10 • • - • • • • • . - " - • "` "" - -- SPRINKLER FINISH' K TYPE NATURAL CHROME WHITE LEAD FACTOR BRASS PLATED POLYESTER COATED • PENDENT (TY1231) and 2 8 UPRIGHT (TY1131) • 1/2" NPT 175 PSI (12,1 BAR) N/A RECESSED PENDENT (TY1231) • PENDENT (TY2231) and UPRIGHT (TY2131) 4.2 175 PSI (12,1 BAR) N/A 1/2" NPT RECESSED 'PENDENT (TY2231) • PENDENT (TY3231) 175 PSI and UPRIGHT (TY3131) 250 PSI (17,2 BAR) (12,1 BAR) 5.6 1/2" NPT OR 175 PSI (12,1 BAR) RECESSED (SEE NOTE 1) • PENDENT (TY3231) N/A PENDENT (TY4231) 175 PSI and • (12,1 BAR) UPRIGHT (TY4131) 8.0 3/4" NPT 175 PSI (12,1 BAR) RECESSED N/A PENDENT (TY4231) PENDENT (TY4931) 1/2" NPT and 175 PSI (12,1 BAR) (12,1 BAR) UPRIGHT (TY4831) NOTES: • 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C -UL); and, the Approval by the City of New York. • • TABLE C • MAXIMUM WORKING PRESSURE • The Series TY -FRB Recessed Pendent Care and' Exercise care to avoid damage to Sprinklers must be installed in accor- . . and' sprinklers before, during, and after dance with the following instructions. • installation. Never paint, plate, coat, 1. After Installing the•Style 10, 20, 30, Maintenance or otherwise alter automatic sprinklers or 40 Mounting Plate, as applica- The TYCO Series TY -FRB must be after they leave the factory. • bie, over the sprinkler threads and maintained and serviced in accordance Replace sprinklers that: with pipe- thread sealant applied to with the following instructions. • were modified or over - heated. the pipe threads, hand - tighten the sprinkler into the sprinkler fitting. • were damaged by dropping, striking, NOTICE ° • wrench twisting, wrench slippage, or 2. Tighten the sprinkler into the sprin- Before c losing a fire protection system the like. kler fitting using only the W - Type 7 main control valve for maintenance Recessed Sprinkler Wrench Fi • are leaking or exhibiting visible signs p g- • work on the fire protection system ure 15). With reference to Figures 1 that it controls, obtain permission to of corrosion. to 4, apply the W-Type 7 Recessed shut down the affected fire protection • were exposed to corrosive products Sprinkler Wrench to the sprinkler systems from the proper authorities of combustion but have not oper- wrench flats. and notify all personnel who may be ated, if you cannot easily remove 3. After ceiling installation and finish- affected by this action. combustion by- products with a cloth. ing, slide•on the Style 10, 20, 30, or Absence of the outer piece of an • have a cracked bulb or have lost liq- 40 Closure over the Series TY -FRB escu which is used to cover uid from the bulb. Refer to the Instal - Sprinkler and push the Closure over a clearance hole, can delay sprinkler lation section in this data sheet. • the Mounting Plate until its flange operation in a fire situation. comes in contact with the ceiling. • . TFP171 • Page 8 of 10 . 2 -7/8° DIA. 2 -7/8" DIA. - - - . - . .. -. (73.0 mm) - . . -- _ .." r19,1 ,. - - - - . . _ - --I/2±1/8" .. -- - (73,0 mm) - . 3/4" mm) _ ' S/8 ±1/4" 1/2" (12,7 mm) (15,9±6,4 mm) 2 1/4° DIA. 1/4 °(6,4 mm) (12,7 ±3,2 mm) 2 -1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING FACE OF (57,2 mm) SPRINKLER MOUNTING PLATE SP p1/8 FITTING - FITTING T NG 1/8" 1/8" s- (3,2 mm) ■. (3,2 mm) J I 1.Ii AM ME W MOUNTING If I I MOUNTING SURFACE SURFACE "r/VP.,1,,. "VT,' FW • CLOSURE SERIES 1-5/167(33,3 mm) CLOSURE SERIES 1- 5/16" (33,3 mm) TY -FRB' 13/16" (20,6 mm) • TY-FRB 1- 1/16" (27,0 mm) ' • FIGURE 6 FIGURE 7 • SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO - PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON • STYLE 20 RECESSED ESCUTCHEON 2.8 K- FACTOR, 1/2 INCH NPT _ 2.8 K- FACTOR, 1/2 INCH NPT 2 -7/8" DIA. 2 -7/8" DIA. ' S/8 ±1/4" ( mm) 3/4" (19,1 mm) .. (73,0 mm) 1/2" (12,7 mm 1/2±1/8" ( mm) (15,9±6,4 mm) 2 -1/4" DIA. 1/4" (6,4 mm) (12,7 ±3,2 mm) 2 -1/4" DIA. 1/4° (6,4 mm) FACE OF (57,2 mm) MOUNTING FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" 1/8" ' n ( 3,2 mm) .. (3,2 mm) I a il , VA r i . \ MOUNTING lip - t , MOUNTING - N , SURFACE SURFACE ..__•__.. . -- • • CLOSURE SERIES 1 -1/4" (31,8 mm) SERIES 1 -1/4" (31,8 mm) (19,1 mm) CLOSURE - TY-FRB 3/4" TY-FRB ( ) 1" (25,4 mm) FIGURE 8 • - FIGURE 9 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO -PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON . 4.2 K- FACTOR, 1/2 INCH NPT 4.2 K- FACTOR, 1/2 INCH NPT Initial and frequent visual inspections of Responsibility lies with the owner for Care must be exercised to avoid dam- ' random samples are recommended for the inspection, testing, and mainte- age to the sprinklers - before, during, corrosion- resistant sprinklers to verify nance of their fire protection system and after installation. Sprinklers dam - the integrity of the corrosion- resistant and devices in compliance with this aged by dropping, striking, wrench material of construction. Thereafter, document, as well as with the appli- twist /slippage, or the like, must be annual inspections per NFPA 25 should cable standards of the National Fire replaced. Also, replace any sprinkler suffice. Protection Association (for example, that has a cracked bulb or that has lost Inspections of corrosion - resistant NFPA 25), in addition to the standards liquid from its bulb. (Ref. Installation sprinklers are recommended at close of any other authorities having jurisdic- Section). lion range, instead of from the floor level tion. Contact the installing contractor or Initial and frequent visual inspections of per NFPA. Inspection at close range sprinkler manufacturer regarding any random samples are recommended for can better determine the exact sprin- questions. corrosion- resistant sprinklers to verify • • kier condition and the long -term integ- Automatic sprinkler systems are rec- the integrity of the corrosion - resistant rity of the corrosion- resistant material, ommended to be inspected, tested, - material of construction. Thereafter, which can be affected by the corrosive and maintained by a qualified Inspec- annual inspections per NFPA 25 should conditions present. tion Service in accordance with local suffice. requirements and /or national codes. • • " TFP171 Page 9 of 10 2 -7/8" DIA. 2 -7/8" DIA. • 5/8 ±1/4° ( mm) . ° _ 3/4 (19,1 mm) 1/2±1/8° (73,0 mm) _ 1/2" (12,7 mm) ' (15,9±6,4 mm) 2 -1/4° DIA. 1/4 "(6,4 mm) (12,7 ±3,2 mm) 2 -1/4° DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING . FITTING 1/8" '.- (3,2 mm) ■. (3,2 mm) Fil mi,i r , �lIlli r i1 Ii • ��• II t A4 N a MOUNTING 11' ■AIININNIN k•./ MOUNTING , SURFACE f NA SURFACE —— --• • _ 1 CLOSURE SERIES 1 -1/4° (31,8 mm) CLOSURE SERIES 1 -1/4" (31,8 mm) TY -FRB 3/4" (19,1 mm) TY-FRB 1" (25,4 mm) . FIGURE 10 FIGURE 11 • SERIES TY-FRB RECESSED PENDENT . SERIES TY-FRB RECESSED PENDENT WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT . WITH TWO -PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON . •.. STYLE 20 RECESSED ESCUTCHEON 5.6 K- FACTOR, 1/2 INCH NPT • 5.6 K- FACTOR, 1/2 INCH NPT 2 -7/8° DIA. 2 -7/8" DIA. 5/8±1/4" (73,0 mm) 3/4" (19,1 mrn) 1/2 ±1/8° (73,0 mm) 1/2" (12,7 mm) (15,9±6,4 mm) 2 -1/4° DIA. 1/4" (6,4 mm) (12,7±3,2 mm) 2 -1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) 1 MOUNTING ~ (57,2 mm FACE OF mm) MOUNTING — SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" I 1/8" u (3,2 mm) u (3,2 mm) • . Aillimm �.rlli . ��,>rU! r _> � + f • '�, l i MOUNTING Id } ■ ° MOUNTING I SURFACE SURFACE 11 , • S ■ CLOSURE SERIES 1- 5/16" (33,3 mm) CLOSURE SERIES 1 -5/16" (33,3 mm) • TY-FRB 13/16" (20,6 mm) TY-FRB 1 -1/16" (27,0 mm) FIGURE 12 FIGURE 13 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO -PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO -PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON STYLE 30 RECESSED ESCUTCHEON 8.0 K- FACTOR, 3/4 INCH NPT 8.0 K- FACTOR, 3/4 INCH NPT Inspections of corrosion - resistant sprinklers are recommended at close 4r.:-.. WRENCH range, instead of from the floor level RECESS per NFPA. Inspection at close range WRENCH RECESS can better determine the exact sprin- (END "A" USED FOR l kler condition and the long -term integ- rity of the corrosion - resistant material, ---• 1/2" NPT MODELS) which can be affected by the corrosive conditions present. WRENCH RECESS 0 t (END "B" USED FOR 3/4" NPT MODELS) PUSH WRENCH IN TO • ENSURE ENGAGEMENT WITH FIGURE 14 SPRINKLER WRENCHING AREA W -TYPE 6 SPRINKLER FIGURE 15 • WRENCH W -TYPE 7 RECESSED SPRINKLER WRENCH • TFP171 Page 10 of 10 P/ N 57 - XXX - X - XXX - - - - I I - ---- - .. _ . _. .. MODEUSIN SPRINKLER TEMPERATURE FINISH RATINGS • 330 2.8K UPRIGHT (1 /2 "NPT) TY1131 1 NATURAL BRASS 135 135 °F (57 °C) 331 2.8K PENDENT (1 /2 "NPT) TY1231 4 WHITE POLYESTER 155 155 °F (68 °C) 340 4.2K UPRIGHT (1 /2 "NPT) TY2131 3 WHITE (RAL9010)' 175 175 °F (79 °C) • 341 4.2K PENDENT (1 /2 "NPT) TY2231 9 CHROME PLATED 200 200 °F (93 °C) 370 5.6K UPRIGHT (1 /2 "NPT) TY3131 7 LEAD COATED 286 286 °F (141 °C) 371 5.6K PENDENT (1 /2 "NPT) • TY3231 390 8.0K UPRIGHT (3 /4 "NPT) TY4131 391 8.0K PENDENT (3/4 "NPT) , TY4231 360 8.0K UPRIGHT (1 /2 "NPT) TY4831' * Eastern Hemisphere sales only. 361 8.0K PENDENT (1 /2 "NPT) TY4931' TABLE D PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS . Limited responsible for sprinkler system design Ordering errors or inaccurate or incomplete infor- Warranty mation supplied by Buyer or Buyer's Procedure representatives. 6r Products manufactured by Tyco Fire In no event shall TFSBP be liable, - in. Contact your .local distributor for Suppression & Building Products contract, tort, strict liability or under availability. When placing an order, (TFSBP) are warranted solely to. the any other legal theory, for incidental, indicate the full product name and Part • original Buyer for ten (10) years against indirect, special or consequential dam- Number (P /N). defects in material and workmanship ages, including but not limited to labor when paid for and properly installed charges, regardless of whether TFSBP Sprinkler Assemblies with NPT and maintained under normal use and was informed about the possibility of Thread Connections . service. This warranty will expire ten such damages, and in no event shall Specify: (Specify Model /SIN), Quick (10) ear from date is of shi rot by TFSBP's liability exceed an amount Response, (specify K- factor), (specify equal to the sales price. temperature rating), ucts or components manufactured by p g), Series TY -FRB companies not affiliated by ownership The foregoing warranty is made in lieu (specify Pendent or Upright) Sprinkler with TFSBP or for products and corn- of any and all other warranties, express with (specify type of finish or coating), ponents which have been subject to or implied. including warranties of mer- P/N (specify from Table D). misuse, improper installation, corro- chantability and fitness for a particular Recessed Escutcheon: sion, or which have not been installed, purpose. Specify: Style (10, 20, 30, or 40) maintained, modified or repaired in This limited warranty sets forth the Recessed Escutcheon with (specify *) accordance with applicable Standards exclusive remedy for claims based on finish, P/N (specify *). of the National Fire Protection Associa- failure of or defect in products, materi- tion, and /or the standards of any other als or components, whether the claim is Sprinkler Wrench Authorities Having Jurisdiction. Mate- made in contract, tort, strict liability or Specify: W -Type 6 Sprinkler Wrench, rials found by TFSBP to be defective any other legal theory. P/N 56- 000 -6 -387. shall be either repaired or replaced, at TFSBP's sole option. TFSBP neither This warranty will apply to the full Specify: W -Type 7 Sprinkler Wrench, assumes, nor authorizes any person extent permitted by law. The invalidity, P/N 56- 850 -4 -001. • to assume for it, any other obligation in in whole or part, of any portion of this • Refer to Technical Data Sheet TFP770. • connection with the sale of products or warranty will not affect the remainder. parts of products. TFSBP shall not be Copyright © 2007 -2010 Tyco Fire Suppression & Building Products. All rights reserved. [Page Too Large for OCR Processing]