Specifications • 4 EC 20 I t 31 4,
•
SUBMITTA
•.
Job Title: WETZEL PRETZEL
Date: 06/02/11
Submitted By: Chris Hessick
JOHNSON AIR PRODUCTS
2220 SE NINTH AVENUE
PORTLAND , OR 97214
US
Phone: (503)234 -5071
Fax: (503)233 -0451 . •
Email Address: chessick @johnsonair.com
EF -1 Roof Cap by others
•
•
•
LSGREENHECK
Building Value in Air.
P.O. Box 410 Schofield, WI 54476 (715) 359 -6171 FAX (715) 355 -2399 www.greenheck.com •
CAPS 4.6.998 G: \Job Data Files \Josh \WETZEL PRETZEL.gcj Page 1 of 9
.0GREENHECK J b WETZEL PRETZEL
Building Value in Air. Product Type: Fan
Mark: EF -2
28.88 Model: CUE -141 -B
Dia. Direct Drive Upblast Centrifugal Roof Exhaust Fan
Standard Construction Features:
- Aluminum housing - Backward inclined aluminum wheel - Aluminum curb cap
with prepunched mounting holes - Drain trough - Ball bearing motors (sizes
I V I 1 98 -160), sleeve bearing motors (sizes 60 -95) - Motor isolated on shock mounts -
Corrosion resistant fasteners
` I Options & Accessories:
29.75 PSC Motor
4 I ��1
-- UUcUL 705 Listed - "Power Ventilators"
19.39 Switch, NEMA -1, Toggle, Junction Box Mounted & Wired
IIKAM Roof Curb, GPI- 22 -G12, Under Sized 1.5 in Total
Damper, WD- 100 -PB- 16X16, Gravity Operated (Loose)
-'I. [1.75 Solid State Speed Control, Shipped Loose (PN 5WSSC)
1 22
Dimensional
Weight w/o Weight with Roof Optional
Qty Accessories Accessories Opening Damper
(Ib) (Ib) (in) (in)
1 72 99 18.5x18.5 16x16
Performance
' Requested Actual Requested Actual Operating Airstream Tip
Volume Volume SP SP Fan Power Elevation Temperature Speed SE
(CFM) (CFM) (in wg) (in wg) RPM (hp) (ft) (F) (fUmin) (%)
760 760 0.3 0.3 726 0.07 0 70 2778 51.8
Motor Sound Power by Octave Band
Motor Size Motor NEC Sound 62.5 125 250 500 1000 2000 4000 8000 LwA dBA Sones
Mounted (hp) V /C /P End. RPM Windings FLA* Data
(Amps) Inlet 66 67 57 53 54 _ 46 38 _ 31 58 46 4.1
Yes 1/4 115/60/1 ODP 1140 1 5.8
0.40 ' 0.08
.726 RPM •
0.35 0.07 amca
- OERTIfED
0.30 0,06
RRTIR61
•
fOURD
3 0.25 0.05 ' AIR
C L ,n
v
MR
0.20 0.04 3 IIIOyfrllfnT
RnD OOATROt
N R11OClRTIOn
co : d rn T[RnnTIOnnL Inc.
•
CL . 0.15 0.03
U L O
l° ca
.
- 0.10 0.02
0.05
0' \ 0.01 Notes:
All dimensions shown are in units of in.
0.00 - \ 0.00 - FLA - based on tables 150 or 148 of National Electrical
0 2 4 6 8 10 12 14 Code 2002. Actual motor FLA may vary, for sizing thermal
overload, consult factory.
LwA - A weighted sound power level, based on ANSI S1.4
Volume (CFM) x 100 dBA - A weighed sound pressure level, based on 11.5 dB
RPM Curve attenuation per Octave band at 5.0 ft - dBA levels are not
- • - • - • • -System licensed by AMCA International
Brake Power Curve Sones - calculated using AMCA 301 at 5.0 ft
Do not se:ect to the left of this surge curve
8 Desired operating p oint
Actual operatin po
CAPS 4.6.998 G: \Job Data Files \Josh \WETZEL PRETZEL.gcj Page 2 of 9
LGREEA'HECK _ • Printed Date: 6/2/2011
J ob: WETZEL PRETZEL
Building Value in Air. Product Type: Fan
Mark: EF -2
• : Disconnect Switch
-- Enclosure- Rating:•NEMA -1 - - -
Standard Construction Features:
Enclosure constructed for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed
equipment and to provide a degree of protection against falling dust. This enclosure meets the rod entry and the indoor
corrosion protection design tests. The rod entry test is intended to simulate incidental contact with enclosure equipment.
Enclosure is equipped with provision to lockout in the off position with customer supplied lock.
Disconnect Switch Configuration
Type: Toggle Motor Size: 1/4 hp Voltage: 115 UL Listed: Yes
Manufacturer: Pass and Seymour Cycle: 60 Amperage: 15 CSA Approved: No
Overload Protection: None Phase: 1 Switch Pole(s): 1 Rating: 1/2 hp
Mounting: Mounted and Wired RPM: 1140 Wiring (Exp. Resist.): None
Electrical Drawing Details
00.28
(4 HOLES) Wiring •
• Schematic
O
k
• p
4.35 •
1.06
• •
1.65 • 65 0
0.72 L.-2.00 — I
- 1.06
2.50 0
Notes: All dimensions shown are in units of in
CAPS 4.6.998 G: \Job Data Files \Josh \WETZEL PRETZEL.gcj Page 3 of 9
•
•
.L GREENHECK Panted Date: 6/2/2011
J ob: WETZEL PRETZEL
• Building Value in Air. Product Type: Fan
• Mark: EF -2
•
Assembly Drawi
. • Type: Direct Drive Upblast Centrifugal Roof Exhaust Fan . •
16.0 18.5
Exhaust Damper & Ductwork SQ SQ
Suggested
Roof Opening
TOP VIEW
-28.9 Dia. -
29.8
19.4
•
� / r 1.8 I 31.4
+
I_
22.0 1 12.0
Flat Roof Curb J
FRONT VIEW
•
Notes: All dimensions shown are in units of in.
The following accessories ship loose unless otherwise specified; Roof Curb, Curb
Extension, Curb Cap Adaptor, Windband Extension, Damper.
CAPS 4.6.998 G: \Job Data Files \Josh \WETZEL PRETZEL.gcj Page 4 of 9
•
•
. IGREENHECK Printed Date: 6/2/2011
Job: WETZEL PRETZEL
Building Value in Air Product Type: Fan
.. : Mark: EF -2
Roof Curb .
Model: - GP -I - • _ ... - ..
Standard Construction Features:
- Roof Curb fits between the building roof and the fan mounted directly to the roof support structure - Constructed of either 18
ga galvanized steel or 0.064 in aluminum - Straight Sided without a cant - 2 in mounting flange - 1 in thick 3 lb density insulation
- Height - Available from 8 in to 24 in as specified in 0.5 in increments.
Notes:
- The Maximum roof opening dimension should not be greater than the "Actual" top outside dimension minus 2 in.
- The minimum roof opening dimension should be at least 2.5 in more than the damper dimension or recommended duct size.
= The Roof Opening Dimension may NOT be the Structural Opening Dimension.
- Damper Tray is optional and must be specified. Tray size is same as damper size.
- Security Bars are optional and must be specified. They are 0.5 in thick steel rods welded 6 in on center and welded to the roof
curb when coated with Permatector.
•
20.5 20.5
12.0
24.5 24.5
ISOMETRIC VIEW
Notes: All dimensions shown are in units of in
' CAPS 4.6.998 G: \Job Data Files \Josh \WETZEL PRETZEL.gcj Page 5 of 9
LS GREEA'HECK Printed Date: 6/2/2011
Job: WETZEL PRETZEL
Building Value in Air. Product Type: Fan
Mark: EF -2
. Horizontal Mount Exhaust Damper
Model: WD -100
Standard Construction Features:
- Horizontal mount exhaust damper (air flow up) is constructed of 18 ga galvanized steel with pre - punched mounting holes -
Damper blades are 0.025 in roll formed aluminum with vinyl seals on the closing edge, and spring assisted for ease of opening
- Steel axles are 0.188 in diameter zinc plated mounted in acetal bushings - Synthetic axle bearings
Accessory Configuration
Actuator Type: Gravity
End Switch: No •
16 16
TYP. SECTION VIEW
DAMPER
Notes: All dimensions shown are in units of in
Width And height furnished approximately 0.125 in undersize
CAPS 4.6.998 G: \Job Data Files \Josh \WETZEL PRETZEL.gcj Page 6 of 9
Printed Date: 6 /2/2011
•
�GREENHECK Job: WETZEL PRETZEL
Building Value in Air. Product Type: Fan
Mark: EF -2
• AMCA
AMCCi
CE
E
RA T IflM
SO URD
anu
RIR
PER►oamnncE
AIR
AIOVEmEAT
AAD COATROI
ASSOCIATIOA
IATERAATIOAAI. IRO.
AMCA Licensed for Sound and Air Performance Without Appurtenances (Accessories). Power rating (BHP /kW) does not
include transmission losses.
• • GreenheckFanCorporation certifies that the model shown herein is licensed to bear the AMCA Seal. The ratings shown
are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and
comply with the requirements of the AMCA Certified Ratings Program. Performance certified is for installation type A:
. Free inlet, Free outlet. Power rating (BHP /kW) does not include transmission losses. Performance ratings do not include
the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in
a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: free inlet
hemispherical sone levels. dBA levels are not licensed by AMCA International. The AMCA Certified Ratings Seal applies
to sone ratings only.
•
The AMCA licensed air and /or sound performance data has been modified for installation, appurtenances or accessories,
etc. not included in the certified data. The modified performance is not AMCA licensed but is provided to aid in selection
and applications of the product.
CAPS 4.6.998 G: \Job Data Files \Josh \WETZEL PRETZEL.gcj Page 7 of 9
Printed Date: 6/2/2011
. . . . .
. GREENHECK • _ yob WETZEL PRETZEL • • Building Value in Air. Product Type: Fan
. . Mark:. Copy of EF -1
SP 10.625 13.25. . . _ .. . _
. r
Ceiling Exhaust Fan
Tag Copy of EF -1
STANDARD CONSTRUCTION FEATURES
• Corrosion resistant galvanized steel scroll and housing • Sound absorbing
insulation • White designer non - yellowing grille • Outlet duct collar with integral •
9 spring loaded backdraft damper • Double inlet forward curved wheel • Plug type
/ disconnect • Adjustable mounting brackets • Field rotatable discharge
SELECTED OPTIONS & ACCESSORIES
UL/cUL 507 Listed - "Electric Fans"
• Solid State Speed Control, (PN: 5WSSC) Shipped Loose
Designer Grille
/1`\ Polypropylene Wheel Material
• 14.87
•
25
\r
•
NOTES: All dimensions shown are in units of inches
Fan weight is without accessories
DIMENSIONS
Approx. Fan
Weight (lb)
18
PFRFORMANCE (Flevatinn ft = (, Airstream T'mperature = = 70)
Motor Information
Volume Qty Model (CFM) SP (in wg) FRPM Watts (W) Amps— — V /C /P Encl:. RPM •
• 1 SP -Al25 100 0.25 1,072 53 0.6 115/60/1 ODP 1100
• SOUND .
Inlet Sound Power by Octave Band Lwa dBA Spherical LwA - A weighted sound power level, based on ANSI S1.4.
62.5 125 250 500 1000 2000 4000 8000 Sones Sones calculated using AMCA 301 at 5.0 ft in a spherical field.
56 56 48 46 40 32 26 27 47 36 1.2 dBA - A weighted sound pressure level, based on 11.5 dB
attenuation per octave band at 5.0 ft.
Sones are at 0.1 inches of wg dBA levels are not licensed by AMCA International.
0.5
•
— • .i
0.4 OERT1f CD
Karma
•
sop)
•
0.3 ' RIR In
— AIR
• tllO7fI11007
•
— Yf10 0047401 •
_ I ' 1100C1117104
111701111171011111. I T O.
0.2 • o
7
• •
0.0 J••'I_�I.•,0 •• ( "I • I • 1 I 1 I I 1 1 I 1 1 1 1 I i
0 20 40 60 80 100 120 140
Volume (CFM)
RPM Curve
— • • System Curve
Broke Power Curve
Do not select to the left of this surge curve
CAPS 4.6.998 G: \Job Data Files \Josh \WETZEL PRETZEL.gcj Page 8 of 9 •
•
' Printed Date: 6/2/2011 •
•
� Job: WETZEL PRETZEL
Building Value in Air. Product Type: Fan
Mark: Copy of EF = 1
• AMCA
A fY1C I L1
CERTi'IED
RATIRGZ
SOURD
ono
AIR
PERFORfM00E
AIR
AIOVEAIEAT
AAD COATROI
ASSOCIATIOA
IATERAATIOAAI. IAC.
AMCA Licensed for Sound and Air Performance Without Appurtenances (Accessories). Power (BHP /kW) excludes drives.
GreenheckFanCorporation certifies that the model shown herein is licensed to bear the AMCA Seal. The ratings shown
are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and
comply with the requirements of the AMCA Certified Ratings Program. Performance certified is for installation type B: Free
• inlet, Ducted outlet. Performance ratings include the effects of an inlet grille and backdraft damper. Speed (RPM) shown is
nominal. Performance is based on actual speed of test. The sound ratings shown are for loudness values in spherical
sones at 5ft. (1.5m) in a spherical free field calculated per Annex B of AMCA 311. Values shown are for installation type
B: free inlet spherical sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.
•
The AMCA licensed air and /or sound performance data has been modified.for installation, appurtenances or accessories,
etc. not included in the certified data. The modified performance is not AMCA licensed but is provided to aid in selection
and applications of the product.
CAPS 4.6.998 G: \Job Data Files \Josh \WETZEL PRETZEL.gcj Page 9 of 9
TRA /E Submittal
•
•
EC2a1,1 -o03 i `t-
Prepared For: Date:
"Grey Wolf HVAC May 16, 2011 •
Job Name:
Wetzel's Pretzels
Trane U.S. Inc. is pleased to provide the enclosed submittal for your review and approval.
Product Summary
Qty Product Specification Section
1 Trane Variable Air Volume Fan Powered Terminal Unit Per Plans
•
• The attached information describes the equipment we propose to
furnish for this project, and is submitted for your approval.
Matt ()Manion
Trane
7257 SW Kable Lane
Portland, OR 97224 -7181
Phone: (503) 620 -8031
Fax: (503) 639 -1454
Comments:
1) Please verify if power connections should be RH or LH. Unit is shown as LH.
2) Unit is provide to operate standalone and will be factory setup for design conditions per schedule. Any
modifications (if necessary) with require the Trane Rover Service Tool. If the contractor and /or air balancer
does not have this tool, TraneOregon can provide this service at $145 per hour. .
•
J:IJOBSI124146353121Submittal (Rev. 0).doc
• Table Of Contents
Product Summary 1
Variable Air Volume Fan Powered Terminal Units (Item Al)
Tag Data 3
Product Data 3
Performance Data 3
Mechanical Specifications 4
Unit Dimensions 8
Accessory 9
Field Wiring 12
Field Installed Options - Part/Order Number Summary
Variable Air Volume Fan Powered Terminal Units 14
Wetzel's Pretzels May 16, 2011 .
Tag Data - Variable Air Volume Fan Powered Terminal Units Qty: '1) . ... • , ..
• I Item Tag(s) Qty Description Model Number
Al. .. FP -1 .1 VAV Fan Powered Terniinal Units VPEF1004SQ
•
• Product Data - Variable Air - Volume Fan Powered Terminal Units •
Item: Al Qty: 1 Tag(s): FP -1 • .
• Parallel Fan Powered w/ Electric Heat
_ 10" Inlet
1" Foil Faced Insulation
Size 04 Super Quiet Fan •
Single Speed Motor w/ SCR Control
Factory Mounted Trane Controls and Actuator
9.0 kW Electric Heat (1- Stage)
208V/3 Electrical w/ Disconnect and Power Fuse
Slip and Drive Connection
1 DDC Zone Sensor w/ Set Point and Occupancy Control (Fld)
1 DDC Duct Auxiliary Temperature Sensor (Fld)
Terminal Unit Notes:
1) Less (or by others): Installation, storage, rigging, seismic calculations /restraints, hangers, isolators, spares, conduit,
power wire /wiring, controls wire /wiring, interface to DDC, air balance, start-up, configuration, programming, owner
training, installation of field accessories (Fld), and labor warranty.
Performance Data - 'Variable Air Volume Fan Powered Terminal Units
Tags FP -1
Design cooling airflow (cfm) 1150
•
Min cooling airflow (cfm) 0
Valve heating airflow (cfm) 0
Cooling inlet diameter (in) 10.000
Cooling inlet velocity (ft/min) 2108
APD @ cooling airflow (in H2O) 0.049
Fan airflow (cfm) 1100 .
Downstream SP (in H2O) 0:500
Fan TSP (in H2O) 0.513
• % of fan range ( %) 99.00
Fan power (hp) 0:333
Plenum EAT (F) 75.00
Primary EDB (F) 55.00
Operating weight (lb) 114.0
Unit heating airflow (cfm) 1100
• Coil heating capacity (MBh) 30.74
Room heat loss (MBh) 36.70
Room heating setpoint (F) 70.00
Coil EAT (F) 75.00
Unit LAT (F) 100.75
Coil LAT (F) 100.75
Full load amps (A) 30.48
Min circuit ampacity (A) 38.10
Max overcurrent protection (A) 40.00
Electric heater kW (kW) 9.00
FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 14
Others
•
Wetzel's Pretzels May 16, 2011
Mechanical Specifications - Variable Air Volume Fan Powered Terminal Units
Item: Al . Qty: 1 Tag(s): FP -1
•
General Unit Information
Casing - The unit casing is 22 gauge galvanized steel. Outlet duct connection is flanged.
Total metal encapsulation of all insulation edges. Hanger Brackets provided. Side access is provided.
Filter - A filter is provided on the plenum inlet.
Agency Listing - UL and Canadian UL listed as environmental air terminal unit. UL Control #9N65. All Trane terminal
units are AHRI 880 -98 certified.
General Unit Clearance
Leave a minimum of 36" on control box side of unit for adequate service access. Allow at least 12" on remaining sides
for unit clearance. A minimum of one and one half duct diameters of straight duct work, upstream of the air inlet
connection, should be present for optimum airflow measurement performance. Upstream duct work should be the same
diameter as the primary inlet connection.
1" [25.4 mm] Foil - Faced Insulation
The interior surface of the unit is acoustically and thermally lined with 1", 1.5 lb /cu. ft density glass fiber with a foil facing.
The insulation is UL listed and meets NFPA -90A, UL 181 standards, and bacteriological standard ASTM C 665. All
insulation options will meet the 25/50 smoke developed and flame spread rating (per ASTM E 84 and UL 723 and
CAN /ULC S102- M88) NFPA- 90B. The insulation R -value is 4.1. All cut edges of insulation are completely
encapsulated in metal to prevent erosion.
Air Valve & Fan Description (Parallel) (Series) •
The air inlet connection is an 18 gauge galvanized steel cylinder sized to fit standard round duct. A multiple point,
averaging flow sensing ring is provided with balancing taps for measuring airflow within +/- 5% of unit cataloged airflow.
Also provided with each unit is a calibration chart indicating airflow versus flow sensor pressure differential. The damper
blade is constructed.of a closed cell foam seal mechanically locked between two 22 gauge galvanized steel disks. The
damper blade assembly is connected through a composite nylon stub axle to a cast zinc shaft supported by self
lubricating bearings. The shaft is cast with a damper position indicator. The valve assembly includes a mechanical stop
to prevent over stroking.
Air valve leakage <1% at 4 ". _
1004SQ Air Valve /Fan Combination Size (Parallel)
10" Inlet designed for up to 1400.0 cfm. Fan is 1350.0 cfm for Std Motor and 1510.0 cfm for ECM Motor.
Motor
Single Speed, direct drive induction, permanent split capacitor type. Thermal overload protection provided. Motors will
be designed specifically for use with an open SCR which is standard. Motors will accommodate anti - backward rotation
at start up. Motor and Fan assembly are isolated from terminal unit.
Transformer
The 50 VA transformer is factory mounted in the fan control box to provide 24 VAC for controls.
Fuse
Any electric heat unit with a calculated MCA greater or equal to 30 will have a fan fuse provided.
SCR- Variable Fan Speed Control: Switch
The SCR speed control device allows the operator infinite fan speed adjustment so the fan output may be modified to
achieve exact CFM requirements.
Electric Heat Coil
Factory provided and mounted. ULrecognized, resistance open -type heater, a disc -type automatic thermal primary
safety device and manual reset load thermal secondary device. Heater element material is nickel- chromium. The heater
terminal box is provided with 7/8" knockouts for customer power supply. Terminal connections are plated steel with
ceramic or phenolic insulators. All fan-powered units with electric reheat are single-point ower n
P power connections. For 480
volt 3 phase and 575 volt 3 phase heaters a 4 wire (includes neutral) power supply is required.
Electric Heat Coil
Factory provided and mounted. Resistance open -type heater, a disc -type automatic thermal primary safety device and
manual reset load thermal secondary device. Heater element material is nickel- chromium. The heater terminal box is
provided with knockouts for customer power supply. Terminal connections are plated steel with ceramic or phenolic
insulators. All fan - powered units with electric reheat are single -point power connections. For 480 volt 3 phase and 575
FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 4 of 14
Others •
Wetzel's Pretzels May 16, 2011
• volt 3 phase heaters a 4 wire (includes neutral) power supply is required. •
Magnetic Contactor
An electric heater 24'volt contact for• use with Direct Digital Control (D.D.C.) or Analog Electronic VAV:Controls.
Power Disconnect Switch (for VSEF & VPEF)
A factory provided interlocking door. disconnect switch located on the electric heater control panel.
•
Airflow Switch
An air pressure device designed to disable the heater when the unit fan is off.
Power Fuse
A safety fuse located in the electric heater's line of power to prevent power surge damage to the electric heater.
Slip & Drive Connection
A slip and drive connection has two straight flanges on the top and bottom, and two drive connections on the left and
right sides. The drive sides are straight flanges which form a "U" shape. The mating ductwork has a similar setup. The
two top and bottom pieces are shaped like a compressed "S" with sealant in the hollow of the "S ". These pieces will
slide over the top and bottom straight flanges. The top and bottom flanges of the mating ductwork will slide into the other
side of these pieces. The two side pieces are shaped like a "C" and are called "Drives ". These pieces will slide over the
"U" shaped flanges so the connection can not be pulled apart. These pieces are usually hammered into place. No
screws are required, and by removing the drives, the ducts may be disconnected. •
•
D.D.C. Actuator
Trane 3 wire, 26 GA, 3.4 VA, 1.7W,- 24 VAC, 50/60 Hz. with floating point control actuator with linkage release button.
Running torque is 35 in -lb minimum; and is non- spring return with 90 second drive time. Travel is terminated by end
• stops at fully opened and closed positions. An integral magnetic clutch eliminates motor stall when Trane controls are
not provided. An integral 3 screw terminal is provided for field wiring. Operating temperature 32.0 F to 125.0 F.
Direct Digital Controller •
The microprocessor based terminal unit controller provides accurate, pressure independent control through the use of a
proportional integral control algorithm and direct control technology. The controller monitors zone temperature set
points, zone temperature and its rate of change, and valve airflow, using a differential pressure signal. Optionally, the
controller can monitor either supply duct air temperature or CO2 concentration via appropriate sensors. The controller
and pressure transducer are installed and factory wired in an enclosure with 7/8" knockouts for remote control wiring. A
Trane zone sensor is required. •
System Communications
The Controller is designed to send and receive data from a Central Control Panel or. other Tracer family products, or a
VariTrac CCP. Current unit status conditions and set points may be monitored and /or edited via this data
communication feature. The network type is a twisted wire pair serial communication.
Override Commands
The following override commands may be received by the Unit Control Module (U.C.M.) from the Tracer System.
Control Mode, Action, & Offset (1.thru 12)
1. Control Mode - The U.C.M. Control Mode may be edited from occupied to unoccupied to accommodate night
setback/setup.
2. Control Action- The Control Action may be edited from cooling to heating, changing the primary air damper to a
heating source. This will accommodate a cooling /heating changeover system:
3. Control Offset- Enabling Control Offset will increase the cooling temperature set point and decrease the heating
temperature set point by a control offset value stored at the U.C.M. This function facilitates demand limiting in the
occupied mode.
4. Drive damper fully open.
5. Drive damper fully closed.
6. Drive damper to maximum airflow set point.
7. Drive damper to minimum airflow set point.
8. Disable unit fan.
9. Disable unit heat.
10. Reset- Enabling the reset function forces the controller and the flow sensor to recalibrate.
11. Programmable hot water valve drive time.
12. Programmable air valve drive time.
FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 5 of 14
Others '
Wetzel's Pretzels May 16, 2011
' Following Unit Set points
The following unit set points reside in the U.C.M. in nonvolatile memory. These set points are editable from the
Command Unit or Tracer via the communications link.
Set points in Nonvolatile Memory (1 thru 8)
1. Occupied cooling temperature set point 60.0 F - 80.0 F.
2. Occupied heating temperature set point 60.0 F - 80.0 F.
3. Unoccupied cooling temperature set point 60.0 F - 100.0 F.
4. Unoccupied heating temperature set point 30.0 F - 100.0 F.
5. Minimum cooling flow set point (0, 10 - 100% of unit equivalent cataloged airflow).
6. Minimum heating flow set point (0, 10 - 100% of unit equivalent cataloged airflow).
7. Maximum flow set point (0,10 - 100% of unit equivalent cataloged airflow).
8. Fan Control Offset - This determines at what operating point the fan in a parallel fan powered unit is energized. This
can be specified as a function of temperature, degrees above heating set point, or primary airflow. 0.0 F - 10.0 F or 0,
10 - 100% of unit equivalent cataloged airflow).
Set points in Nonvolatile Memory (9 Thru 15)
9. Heating Set point Offset - This determines at what point the 1st. stage of reheat turns on. Expressed in degrees
below cooling set point, only applicable when local thumb wheel is enabled.
10. Zone temperature, auxiliary temperature, and zone set point calibration corrections ( +/- 10.0 F).
11. Flow measurement calibration correction (50 - 150 %).
12. Cooling Set point Low Limit - Applies low limit to programmed occupied cooling set point or zone sensor cooling set
point (30.0 F - 100.0 F).
13. Heating Set point High Limit - Applies high limit to programmed occupied heating set point or zone sensor heating
set point (30.0 F - 100.0 F).
14. RTD / Thermistor - Determines what type of zone temperature sensor will be used.
15. Occupied and Unoccupied Outside Air Requirements - Determines the percent of outdoor air required in the zone
for air quality requirements.
Set points in Nonvolatile Memory (16 thru 21)
16. Series Fan Configuration- allows option of series fan powered box to shut off fan and close air valve when unit is
unoccupied. Fan will operate in unoccupied mode if reheat is active.
17. Heating set point low limit.
18. Cooling set point high limit.
19. Local heating flow set point enable /disable & set point.
20. Auxiliary analog input mode select for either auxiliary temperature sensor or CO2 detector.
21. Binary input mode select for either generic or occupancy detector.
Additional Status Information (1 thru 8)
In addition to the above set points, the following status information can be transmitted to the Command Control Unit and
Tracer.
1. Active cooling temperature set point.
2. Active heating temperature set point.
3. Current unit primary airflow.
4. Current zone temperature.
5. Re -heat status (On /Off).
6. Auxiliary Air Temperature - Available only if the unit has an auxiliary temperature sensor.
7. Failure Indicators - The U.C.M. will indicate the following:
*Temperature Sensor Failure
*Flow Sensor Failure
*Local Zone Sensor Set point Failure
8. Ventilation Ratio.
Additional Status Information (9 thru 12)
9. Fan Status (on /off)
10. Calibration Status (calibrating /not- calibrating)
11. BIP state
12. CO2 Concentration- available only if the unit has an auxiliary CO2 sensor. This mode and auxiliary air temperature
are mutually exclusive.
DDC Sequence of Operation
The unit controller continuously monitors the zone temperature against its set point and varies the primary airflow as
required to meet zone set points. Airflow is limited by minimum and maximum airflow set points.
FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 6 of 14
Others
. Wetzel's Pretzels May 16, 2011
•
' Parallel Unit Fan Energization •
• : As the zone temperature reachesithe heating set point, the microprocessor controls airflow to the heating temperature
set point and energizes the auxiliary fan when necessary. At or below the heating set point, reheat is energized. The
heating minimum airflow set point is factory set, field adjustable, and is separate from the cooling minimum set point.
Parallel unit fan energization is a function of primary airflow or zone temperature. •
1. Primary Airflow - The fan energizes when primary airflow drops below the fan set point airflow. The fan automatically
- starts when the zone temperature drops to the heating temperature set point. •
2. Zone Temperature - The fan energizes when the zone temperature drops to a selectable number of degrees above
the heating temperature set point.
Controls Option DD05
Basic Operation: Slow Pulse Width Electric Heat (Normally Open Outputs) (DDC /UCM) (Parallel Units)
A voltage signal from the zone sensor indicating zone temperature is used by the unit controller to determine an error
from the set point. This error, as well as primary flow differential pressure, is used to determine damper position within
minimum and maximum cooling airflow set points. As the zone temperature reaches the heating set point, primary
airflow is controlled to the minimum heating flow set point. The fan operation is intermittent in both modes and is
energized as the first stage of heat. Two stages of electric heat are modulated using the slow pulse width method for
unit reheat.
DDC Zone Sensor w /Setpoint & Occupancy
This electronic device utilizes a thermistor to vary the voltage output in response to changes in the zone temperature.
Wiring to the U.C.M. controls must be 18 to 22 awg. shielded twisted pair wiring. The setpoint adjustment range is 50.0
F 88.0 F. This sensor is provided with an externally adjustable set point, a timed override button and a timed override
cancel button. An optional communications jack is available which snaps into the enclosure backplate.
•
•
•
•
•
•
• •
FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 7 of 14
Others
•
• •Wetzel's Pretzels • • .. May 16, 2011'
• . ' Unit Dimensions- Variable Air - Volume Fan Powered Terminal Units . . .
• Item: Al ' Qty: 1 Tag(s): FP -1. • •
•
•
Unit Size. VPEF1004S0
Nominal 10' Dia..x 4' Depth '
Valve Size 8 Depth
Nominal 04SO Fan >i'•e <.�
Fan Size ..,9 >\. ?.fey >.,•
t �'t.�.
e, 1,�.
Filter Size 16' x 20' x1" (OTY 1) `,? , �;,V.k. •
.q..i tip.. <:
, •
TOP VIEW •
•
20' .
• "n•o-101
' I s•
00 n A NOTES:
AIRFLOW
16.50 x 11.30 31 I 1. Allow a minimum 6' plenum inlet clearance
1 y , t 1 for un-ducted installations.
2. Filter is secured in filter frame located in unit inlet.
32 12• 3. For Motor access, remove bottom screws on • hanger brackets to slide panel as shown in drawing.
4. See Installation Documents for exact hanger
3
z bracket location.
22 m • _ 5. Air valve centered between top & bottom panel.
•
i O
6. be Healing field coil supplied un- insulated. and installed External as required. insulation may
HEATER
m 6• 7. All high & low voltage controls have same -side
NEC jumpback clearance.
' PANEL SLIDES FOR MOTOR ACCESS 8. Allow 48' of straight duct downstream of
AIRFLOW unit before first runout and inside of the duct should
DISCHARGE OUTLET be equal discharge size.
9. Terminal box access door is side hinged. Allow for
clearance.
•
I 10. A 4 wire power supply required for 480\3 & 575 \3
5' 1 • 40' � single point connection units.
T
1
16' 17 1/2'
Approximate 114.01b
4 Dry Weight
Weights reflected may vary
20 ±5.0 lb based upon options
• DISCHARGE VIEW selected.
FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 8 of 14
Others
•
. Wetzel's Pretzels • May 16, 2011
Accessory - ;Variable. Air' Volume` Fan Powered Terminal Units . •
•
• •Item: Al Qty: 1 • ,Tag(s FP -1
• •
•
96.00 0.48 3.40 REF
•
REF
2.00
0.25
t 0.50
2.00 �� re ) 1.50 — s e �
� 1 0.31
\I 1/4' Insulated DC's 6
0.25 Diameter, 2 Holes
PROBE
0.50 —
1.00 — a
SPECIFICATIONS:
• 1.) Sensing element: thermistor located in probe tip
• and sealed in thermally conductive adhesive.
• 2.) Probe sheath: Light drawn thin wall copper
tubing.
3.) Assembly ambient limits:
Shipping and storage temperature is -40.0 F to 160.0 F.
Operating temperature Is -4.0 F tO 212.0 F.
Humidity: 5% to 95% RH non-condensing.
4.) Mounting: any position on duct.
5.) Packaging: Each unit packed in individual plastic
bag w /two #10 -314' long sheet metal mounting
screws and information sheet w /the following
information visible:
'ELECTRONIC DUCT TEMP SENSOR'
6.) Cable is 300V type CL2P with jacket rated at
257.0 F and wires 22 AWG stranded
tinned copper.
FLD = Furnished by Trane U.S. Inc. /Installed by Equipment Submittal Page 9 of 14
Others
Wetzel's Pretzels May 16, 2011
Accessory - Variable Air Volume Fan Powered Terminal Units
Item: Al Qty: 1 Tag(s): FP -1
Notes:
1. When attenuator is required, add inlet attenuator pressure
to discharge static pressure for final fan performance.
VPCF and VPEF maximum
Minimum
1 -row coil maximum
- •- •- • -• -• -• 2 -row coil maximum
Pa In. wg Parallel O4SQ —PSC
199 0.80 '. .
\ \
174 0.70 •
•\ \
\
ID 150 0.60 ` ` \
\
\ \
125 0.50
E y ` S.
a C 5 \
a t o
I°. `
t o 100 0.40 c. \ \ \
m \ \
vi
m 75 0.30 ` • \ \
c \ \
N •
50 0.20 \ \
\ \
\
25 0.10
200 400 600 800 1000 1200 1400 1600 Cfm
94 189 283 378 472 566 661 755 Us
Airflow
•
FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 10 of 14
Others
Wetzel's Pretzels May 16, 2011
Accessory - Variable Air Volume Fan Powered Terminal Units
Item: Al Qty: 1 Tag(s): FP -1
0
41116• lUf
O
TRANE
27/8" 0 1
Customer Notes:
1. Zone Sensor with externally adjustable setpoint, a timed override button &
a timed override cancel button.
2. Optional communications jack available.
FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 11 of 14
Others
Wetzel's Pretzels May 16, 2011
Field Wiring - Variable Air Volume Fan Powered Terminal Units
Item: Al Qty: 1 Tag(s): FP -1
208 Volt, 3 Phase
L3 U L1 N
I I I
I I I
I I I
I I I I
I I I I T
N
Heater
Control
Wiring
® WARNING
HAZARDOUS VOLTAGE!
DISCONNECT ALL ELECTRIC POWER
INCLUDING REMOTE DISCONNECTS
BEFORE SERVICING.
FAILURE TO DISCONNECT POWER
BEFORE SERVICING CAN CAUSE
SEVERE PERSONAL INJURY OR DEATH
L CAUTION
USE COPPER CONDUCTORS ONLY!
UNIT TERMINALS ARE NOT DESIGNED
Customer Notes:
TO ACCEPT OTHER TYPES OF
1. Factory installed.
CONDUCTORS.
FAILURE TO DO SO MAY CAUSE — — — — Optional or installed by others.
DAMAGE TO THE EQUIPMENT.
FLD = Furnished by Trane U.S. Inc. /Installed by Equipment Submittal Page 12 of 14
Others
Wetzel's Pretzels May 16, 2011
' Field Wiring - Variable Air Volume Fan Powered Terminal Units
Item: Al . Qty: 1 Tag(s): FP -1 . ,
•
HEATER
•
TERMINAL DAMPER
BOX WIRING ACTUATOR FAN CONTROL
- WIRING BOX WIRING - _ ... _
- �_ r T81 -1 T82-0 TB33 TB &1
•
TB1-2 I TB25 I TB3-2 I -
I -- -- I —_ I I � I � 1 � I •
2ND STG HEAT 6 6 6 6 6 6
11 10 7 6 3 2 1
>I Z H DIGITAL DISPLAY ZONE SENSOR
0 0 O WI COMM. JACK
1ST STG HEAT m REMOTE MTD.
I 0 .(1 ‘0
I
•
OPTIONAL FIELD INSTALLED
L DIGITAL DISPLAY ZONE SENSOR J
R -FAN
I BR
r TB25 T93-1 7
Y 1 TB2.5 TB3-2
0 1 1 T03-3 1 1
> O m \ m 24VAC BL 1 I ! 1 I I
jirrr'''!!III ` JII000000 1 ry ^ 6 6 i6 6 6
of C19 '- .4[ AGT a � m 2(') !(•J 3 2 1
ZONE SENSOR
BIP GND 24V PRESSURE W/ COMM. JACK
TRANSDUCER REMOTE MTD.
ADDRE D.D.C. \U.C.M. aQ
J 3
SWITCH CONTROL BOARD
R + OPTIONAL FIELD
w� BK I VOUT L INSTALLED ZONE SENSOR J
MBE a 0
I.
o o 1
• m� .cl N� : 0 N0 TEL GRN Ff Frj F� F1 f, O 7, I 24V
(T91•11 24V
m I Y I m m m m J CO2
SENSOR GND 0 (783 -0) GND _
ZONE GND SET A/CO2 GND
OUT V (1' B35IA/CO2
. OPTIONAL FIELD INSTALLED
L CO2 SENSOR
D.D.C. \U.C.M.
S E o o •
CONTROL BOX OPTIONAL • BL
FACTORY I'
INSTALLED Y
WIRELESS
SHIELDED TWISTED PAIR OPTIONAL FACTORY INSTALLED r TB3-5 — I I TB35 1 1
COMMUNICATIONS WIRING WIRELESS I I _— Y 1 I
r �� 24VAC BL
�. 1 I R(HOT) _ (TB1- 1)24VAC -
O(COMMONI_ —_ (T84 -1)BIP C m' m'
_GR (NC CONTACT) _ (TB1.1) 24VAC
BKSRETURNI_ — _ GND 24V
(TB1 -2) GND OPTIONAL
• Y — — — — - NOT CONNECTED L AUX TEMP SENSO J W550 Boots
L
OPTIONAL FIELD INSTALLED
L OCCUPANCY SENSOR J
NOTE: ZN WARNING
• • 1. FACTORY WIRING
FIELD WIRING HAZARDOUS VOLTAGE!
- - - - OPTIONAL OR ALTERNATE WIRING DISCONNECT ALL ELECTRIC POWER
INCLUDING REMOTE DISCONNECTS
2. 1/4 QUICK CONNECT REQUIRED FOR ALL FIELD CONNECTIONS. BEFORE SERVICING.
ZONE SENSOR TERMINALS 1 ( -) AND 2 ( +) REQUIRE SHIELDED TWISTED PAIR WIRING FOR COMMUNICATIONS B BEEFOFORE SE TO DISCONNECT POWER
ERVICING CAN CAUSE
JACK EQUIPPED ZONE SENSOR OPTION. SEVERE PERSONAL INJURY OR DEATH •
Q NO ADDITIONAL WIRING REQUIRED FOR NIGHT SETBACK OVERRIDE (ON /CANCEL). CAUTION
ION
THE OPTIONAL BINARY INPUT CONNECTS BETWEEN TB4 -1 (BIP) AND 24VAC (HOT) FROM USE COPPER CONDUCTORS ONLY!
TRANSFORMER. INPUT CAN BE RECONFIGURED AS AN OCCUPANCY INPUT VIA THE COMMUNICATIONS
UNIT TERMINALS ARE NOT DESIGNED
INTERFACE. TO ACCEPT OTHER TYPES OF
AS SHIPPED. THE AUX INPUT IS CONFIGURED AS AN AUX TEMP INPUT. THE AUX INPUT CAN BE CONDUCTORS.
RECONFIGURED AS A CO2 SENSOR INPUT VIA THE COMMUNICATIONS INTERFACE. FAILURE TO DO SO MAY CAUSE
S TERMINAL NOT TO BE USED WITH VARITRANE.
DAMAGE TO THE EQUIPMENT.
• Q ZONE SENSOR TERMINALS 6 AND 7 REQUIRE SHIELDED TWISTED PAIR
WIRING FOR OPTIONAL USE OF COMMUNICATIONS JACK.
FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 13 of 14
. Others
Wetzel's Pretzels May 16, 2011
' Field Installed Options - Part/Order Number Summary
This is a report to h elp you locate field installed options that arrive at the jobsite. This report provides part or order
numbers for each field installed option, and references it to a specific product tag. It is NOT intended as a bill of
material for the job.
•
Product Family - Variable Air Volume Fan Powered Terminal Units •
I Item. _ Tag(s) . Qty Description - - Model- Number . . . • .
Al FP -1 1 VAV Fan Powered Terminal Units VPEF1004SQ I
Field Installed Option Description Part/Ordering Number
DDC sensor with set point knob and occupancy X13511527010
DDC auxiliary temperature sensor X13790068050
•
•
•
FLD = Furnished by Trane U.S. Inc. /Installed by Equipment Submittal Page 14 of 14
Others