Loading...
Specifications • 4 EC 20 I t 31 4, • SUBMITTA •. Job Title: WETZEL PRETZEL Date: 06/02/11 Submitted By: Chris Hessick JOHNSON AIR PRODUCTS 2220 SE NINTH AVENUE PORTLAND , OR 97214 US Phone: (503)234 -5071 Fax: (503)233 -0451 . • Email Address: chessick @johnsonair.com EF -1 Roof Cap by others • • • LSGREENHECK Building Value in Air. P.O. Box 410 Schofield, WI 54476 (715) 359 -6171 FAX (715) 355 -2399 www.greenheck.com • CAPS 4.6.998 G: \Job Data Files \Josh \WETZEL PRETZEL.gcj Page 1 of 9 .0GREENHECK J b WETZEL PRETZEL Building Value in Air. Product Type: Fan Mark: EF -2 28.88 Model: CUE -141 -B Dia. Direct Drive Upblast Centrifugal Roof Exhaust Fan Standard Construction Features: - Aluminum housing - Backward inclined aluminum wheel - Aluminum curb cap with prepunched mounting holes - Drain trough - Ball bearing motors (sizes I V I 1 98 -160), sleeve bearing motors (sizes 60 -95) - Motor isolated on shock mounts - Corrosion resistant fasteners ` I Options & Accessories: 29.75 PSC Motor 4 I ��1 -- UUcUL 705 Listed - "Power Ventilators" 19.39 Switch, NEMA -1, Toggle, Junction Box Mounted & Wired IIKAM Roof Curb, GPI- 22 -G12, Under Sized 1.5 in Total Damper, WD- 100 -PB- 16X16, Gravity Operated (Loose) -'I. [1.75 Solid State Speed Control, Shipped Loose (PN 5WSSC) 1 22 Dimensional Weight w/o Weight with Roof Optional Qty Accessories Accessories Opening Damper (Ib) (Ib) (in) (in) 1 72 99 18.5x18.5 16x16 Performance ' Requested Actual Requested Actual Operating Airstream Tip Volume Volume SP SP Fan Power Elevation Temperature Speed SE (CFM) (CFM) (in wg) (in wg) RPM (hp) (ft) (F) (fUmin) (%) 760 760 0.3 0.3 726 0.07 0 70 2778 51.8 Motor Sound Power by Octave Band Motor Size Motor NEC Sound 62.5 125 250 500 1000 2000 4000 8000 LwA dBA Sones Mounted (hp) V /C /P End. RPM Windings FLA* Data (Amps) Inlet 66 67 57 53 54 _ 46 38 _ 31 58 46 4.1 Yes 1/4 115/60/1 ODP 1140 1 5.8 0.40 ' 0.08 .726 RPM • 0.35 0.07 amca - OERTIfED 0.30 0,06 RRTIR61 • fOURD 3 0.25 0.05 ' AIR C L ,n v MR 0.20 0.04 3 IIIOyfrllfnT RnD OOATROt N R11OClRTIOn co : d rn T[RnnTIOnnL Inc. • CL . 0.15 0.03 U L O l° ca . - 0.10 0.02 0.05 0' \ 0.01 Notes: All dimensions shown are in units of in. 0.00 - \ 0.00 - FLA - based on tables 150 or 148 of National Electrical 0 2 4 6 8 10 12 14 Code 2002. Actual motor FLA may vary, for sizing thermal overload, consult factory. LwA - A weighted sound power level, based on ANSI S1.4 Volume (CFM) x 100 dBA - A weighed sound pressure level, based on 11.5 dB RPM Curve attenuation per Octave band at 5.0 ft - dBA levels are not - • - • - • • -System licensed by AMCA International Brake Power Curve Sones - calculated using AMCA 301 at 5.0 ft Do not se:ect to the left of this surge curve 8 Desired operating p oint Actual operatin po CAPS 4.6.998 G: \Job Data Files \Josh \WETZEL PRETZEL.gcj Page 2 of 9 LGREEA'HECK _ • Printed Date: 6/2/2011 J ob: WETZEL PRETZEL Building Value in Air. Product Type: Fan Mark: EF -2 • : Disconnect Switch -- Enclosure- Rating:•NEMA -1 - - - Standard Construction Features: Enclosure constructed for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment and to provide a degree of protection against falling dust. This enclosure meets the rod entry and the indoor corrosion protection design tests. The rod entry test is intended to simulate incidental contact with enclosure equipment. Enclosure is equipped with provision to lockout in the off position with customer supplied lock. Disconnect Switch Configuration Type: Toggle Motor Size: 1/4 hp Voltage: 115 UL Listed: Yes Manufacturer: Pass and Seymour Cycle: 60 Amperage: 15 CSA Approved: No Overload Protection: None Phase: 1 Switch Pole(s): 1 Rating: 1/2 hp Mounting: Mounted and Wired RPM: 1140 Wiring (Exp. Resist.): None Electrical Drawing Details 00.28 (4 HOLES) Wiring • • Schematic O k • p 4.35 • 1.06 • • 1.65 • 65 0 0.72 L.-2.00 — I - 1.06 2.50 0 Notes: All dimensions shown are in units of in CAPS 4.6.998 G: \Job Data Files \Josh \WETZEL PRETZEL.gcj Page 3 of 9 • • .L GREENHECK Panted Date: 6/2/2011 J ob: WETZEL PRETZEL • Building Value in Air. Product Type: Fan • Mark: EF -2 • Assembly Drawi . • Type: Direct Drive Upblast Centrifugal Roof Exhaust Fan . • 16.0 18.5 Exhaust Damper & Ductwork SQ SQ Suggested Roof Opening TOP VIEW -28.9 Dia. - 29.8 19.4 • � / r 1.8 I 31.4 + I_ 22.0 1 12.0 Flat Roof Curb J FRONT VIEW • Notes: All dimensions shown are in units of in. The following accessories ship loose unless otherwise specified; Roof Curb, Curb Extension, Curb Cap Adaptor, Windband Extension, Damper. CAPS 4.6.998 G: \Job Data Files \Josh \WETZEL PRETZEL.gcj Page 4 of 9 • • . IGREENHECK Printed Date: 6/2/2011 Job: WETZEL PRETZEL Building Value in Air Product Type: Fan .. : Mark: EF -2 Roof Curb . Model: - GP -I - • _ ... - .. Standard Construction Features: - Roof Curb fits between the building roof and the fan mounted directly to the roof support structure - Constructed of either 18 ga galvanized steel or 0.064 in aluminum - Straight Sided without a cant - 2 in mounting flange - 1 in thick 3 lb density insulation - Height - Available from 8 in to 24 in as specified in 0.5 in increments. Notes: - The Maximum roof opening dimension should not be greater than the "Actual" top outside dimension minus 2 in. - The minimum roof opening dimension should be at least 2.5 in more than the damper dimension or recommended duct size. = The Roof Opening Dimension may NOT be the Structural Opening Dimension. - Damper Tray is optional and must be specified. Tray size is same as damper size. - Security Bars are optional and must be specified. They are 0.5 in thick steel rods welded 6 in on center and welded to the roof curb when coated with Permatector. • 20.5 20.5 12.0 24.5 24.5 ISOMETRIC VIEW Notes: All dimensions shown are in units of in ' CAPS 4.6.998 G: \Job Data Files \Josh \WETZEL PRETZEL.gcj Page 5 of 9 LS GREEA'HECK Printed Date: 6/2/2011 Job: WETZEL PRETZEL Building Value in Air. Product Type: Fan Mark: EF -2 . Horizontal Mount Exhaust Damper Model: WD -100 Standard Construction Features: - Horizontal mount exhaust damper (air flow up) is constructed of 18 ga galvanized steel with pre - punched mounting holes - Damper blades are 0.025 in roll formed aluminum with vinyl seals on the closing edge, and spring assisted for ease of opening - Steel axles are 0.188 in diameter zinc plated mounted in acetal bushings - Synthetic axle bearings Accessory Configuration Actuator Type: Gravity End Switch: No • 16 16 TYP. SECTION VIEW DAMPER Notes: All dimensions shown are in units of in Width And height furnished approximately 0.125 in undersize CAPS 4.6.998 G: \Job Data Files \Josh \WETZEL PRETZEL.gcj Page 6 of 9 Printed Date: 6 /2/2011 • �GREENHECK Job: WETZEL PRETZEL Building Value in Air. Product Type: Fan Mark: EF -2 • AMCA AMCCi CE E RA T IflM SO URD anu RIR PER►oamnncE AIR AIOVEmEAT AAD COATROI ASSOCIATIOA IATERAATIOAAI. IRO. AMCA Licensed for Sound and Air Performance Without Appurtenances (Accessories). Power rating (BHP /kW) does not include transmission losses. • • GreenheckFanCorporation certifies that the model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. Performance certified is for installation type A: . Free inlet, Free outlet. Power rating (BHP /kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: free inlet hemispherical sone levels. dBA levels are not licensed by AMCA International. The AMCA Certified Ratings Seal applies to sone ratings only. • The AMCA licensed air and /or sound performance data has been modified for installation, appurtenances or accessories, etc. not included in the certified data. The modified performance is not AMCA licensed but is provided to aid in selection and applications of the product. CAPS 4.6.998 G: \Job Data Files \Josh \WETZEL PRETZEL.gcj Page 7 of 9 Printed Date: 6/2/2011 . . . . . . GREENHECK • _ yob WETZEL PRETZEL • • Building Value in Air. Product Type: Fan . . Mark:. Copy of EF -1 SP 10.625 13.25. . . _ .. . _ . r Ceiling Exhaust Fan Tag Copy of EF -1 STANDARD CONSTRUCTION FEATURES • Corrosion resistant galvanized steel scroll and housing • Sound absorbing insulation • White designer non - yellowing grille • Outlet duct collar with integral • 9 spring loaded backdraft damper • Double inlet forward curved wheel • Plug type / disconnect • Adjustable mounting brackets • Field rotatable discharge SELECTED OPTIONS & ACCESSORIES UL/cUL 507 Listed - "Electric Fans" • Solid State Speed Control, (PN: 5WSSC) Shipped Loose Designer Grille /1`\ Polypropylene Wheel Material • 14.87 • 25 \r • NOTES: All dimensions shown are in units of inches Fan weight is without accessories DIMENSIONS Approx. Fan Weight (lb) 18 PFRFORMANCE (Flevatinn ft = (, Airstream T'mperature = = 70) Motor Information Volume Qty Model (CFM) SP (in wg) FRPM Watts (W) Amps— — V /C /P Encl:. RPM • • 1 SP -Al25 100 0.25 1,072 53 0.6 115/60/1 ODP 1100 • SOUND . Inlet Sound Power by Octave Band Lwa dBA Spherical LwA - A weighted sound power level, based on ANSI S1.4. 62.5 125 250 500 1000 2000 4000 8000 Sones Sones calculated using AMCA 301 at 5.0 ft in a spherical field. 56 56 48 46 40 32 26 27 47 36 1.2 dBA - A weighted sound pressure level, based on 11.5 dB attenuation per octave band at 5.0 ft. Sones are at 0.1 inches of wg dBA levels are not licensed by AMCA International. 0.5 • — • .i 0.4 OERT1f CD Karma • sop) • 0.3 ' RIR In — AIR • tllO7fI11007 • — Yf10 0047401 • _ I ' 1100C1117104 111701111171011111. I T O. 0.2 • o 7 • • 0.0 J••'I_�I.•,0 •• ( "I • I • 1 I 1 I I 1 1 I 1 1 1 1 I i 0 20 40 60 80 100 120 140 Volume (CFM) RPM Curve — • • System Curve Broke Power Curve Do not select to the left of this surge curve CAPS 4.6.998 G: \Job Data Files \Josh \WETZEL PRETZEL.gcj Page 8 of 9 • • ' Printed Date: 6/2/2011 • • � Job: WETZEL PRETZEL Building Value in Air. Product Type: Fan Mark: Copy of EF = 1 • AMCA A fY1C I L1 CERTi'IED RATIRGZ SOURD ono AIR PERFORfM00E AIR AIOVEAIEAT AAD COATROI ASSOCIATIOA IATERAATIOAAI. IAC. AMCA Licensed for Sound and Air Performance Without Appurtenances (Accessories). Power (BHP /kW) excludes drives. GreenheckFanCorporation certifies that the model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. Performance certified is for installation type B: Free • inlet, Ducted outlet. Performance ratings include the effects of an inlet grille and backdraft damper. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are for loudness values in spherical sones at 5ft. (1.5m) in a spherical free field calculated per Annex B of AMCA 311. Values shown are for installation type B: free inlet spherical sone levels. The AMCA Certified Ratings Seal applies to sone ratings only. • The AMCA licensed air and /or sound performance data has been modified.for installation, appurtenances or accessories, etc. not included in the certified data. The modified performance is not AMCA licensed but is provided to aid in selection and applications of the product. CAPS 4.6.998 G: \Job Data Files \Josh \WETZEL PRETZEL.gcj Page 9 of 9 TRA /E Submittal • • EC2a1,1 -o03 i `t- Prepared For: Date: "Grey Wolf HVAC May 16, 2011 • Job Name: Wetzel's Pretzels Trane U.S. Inc. is pleased to provide the enclosed submittal for your review and approval. Product Summary Qty Product Specification Section 1 Trane Variable Air Volume Fan Powered Terminal Unit Per Plans • • The attached information describes the equipment we propose to furnish for this project, and is submitted for your approval. Matt ()Manion Trane 7257 SW Kable Lane Portland, OR 97224 -7181 Phone: (503) 620 -8031 Fax: (503) 639 -1454 Comments: 1) Please verify if power connections should be RH or LH. Unit is shown as LH. 2) Unit is provide to operate standalone and will be factory setup for design conditions per schedule. Any modifications (if necessary) with require the Trane Rover Service Tool. If the contractor and /or air balancer does not have this tool, TraneOregon can provide this service at $145 per hour. . • J:IJOBSI124146353121Submittal (Rev. 0).doc • Table Of Contents Product Summary 1 Variable Air Volume Fan Powered Terminal Units (Item Al) Tag Data 3 Product Data 3 Performance Data 3 Mechanical Specifications 4 Unit Dimensions 8 Accessory 9 Field Wiring 12 Field Installed Options - Part/Order Number Summary Variable Air Volume Fan Powered Terminal Units 14 Wetzel's Pretzels May 16, 2011 . Tag Data - Variable Air Volume Fan Powered Terminal Units Qty: '1) . ... • , .. • I Item Tag(s) Qty Description Model Number Al. .. FP -1 .1 VAV Fan Powered Terniinal Units VPEF1004SQ • • Product Data - Variable Air - Volume Fan Powered Terminal Units • Item: Al Qty: 1 Tag(s): FP -1 • . • Parallel Fan Powered w/ Electric Heat _ 10" Inlet 1" Foil Faced Insulation Size 04 Super Quiet Fan • Single Speed Motor w/ SCR Control Factory Mounted Trane Controls and Actuator 9.0 kW Electric Heat (1- Stage) 208V/3 Electrical w/ Disconnect and Power Fuse Slip and Drive Connection 1 DDC Zone Sensor w/ Set Point and Occupancy Control (Fld) 1 DDC Duct Auxiliary Temperature Sensor (Fld) Terminal Unit Notes: 1) Less (or by others): Installation, storage, rigging, seismic calculations /restraints, hangers, isolators, spares, conduit, power wire /wiring, controls wire /wiring, interface to DDC, air balance, start-up, configuration, programming, owner training, installation of field accessories (Fld), and labor warranty. Performance Data - 'Variable Air Volume Fan Powered Terminal Units Tags FP -1 Design cooling airflow (cfm) 1150 • Min cooling airflow (cfm) 0 Valve heating airflow (cfm) 0 Cooling inlet diameter (in) 10.000 Cooling inlet velocity (ft/min) 2108 APD @ cooling airflow (in H2O) 0.049 Fan airflow (cfm) 1100 . Downstream SP (in H2O) 0:500 Fan TSP (in H2O) 0.513 • % of fan range ( %) 99.00 Fan power (hp) 0:333 Plenum EAT (F) 75.00 Primary EDB (F) 55.00 Operating weight (lb) 114.0 Unit heating airflow (cfm) 1100 • Coil heating capacity (MBh) 30.74 Room heat loss (MBh) 36.70 Room heating setpoint (F) 70.00 Coil EAT (F) 75.00 Unit LAT (F) 100.75 Coil LAT (F) 100.75 Full load amps (A) 30.48 Min circuit ampacity (A) 38.10 Max overcurrent protection (A) 40.00 Electric heater kW (kW) 9.00 FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 14 Others • Wetzel's Pretzels May 16, 2011 Mechanical Specifications - Variable Air Volume Fan Powered Terminal Units Item: Al . Qty: 1 Tag(s): FP -1 • General Unit Information Casing - The unit casing is 22 gauge galvanized steel. Outlet duct connection is flanged. Total metal encapsulation of all insulation edges. Hanger Brackets provided. Side access is provided. Filter - A filter is provided on the plenum inlet. Agency Listing - UL and Canadian UL listed as environmental air terminal unit. UL Control #9N65. All Trane terminal units are AHRI 880 -98 certified. General Unit Clearance Leave a minimum of 36" on control box side of unit for adequate service access. Allow at least 12" on remaining sides for unit clearance. A minimum of one and one half duct diameters of straight duct work, upstream of the air inlet connection, should be present for optimum airflow measurement performance. Upstream duct work should be the same diameter as the primary inlet connection. 1" [25.4 mm] Foil - Faced Insulation The interior surface of the unit is acoustically and thermally lined with 1", 1.5 lb /cu. ft density glass fiber with a foil facing. The insulation is UL listed and meets NFPA -90A, UL 181 standards, and bacteriological standard ASTM C 665. All insulation options will meet the 25/50 smoke developed and flame spread rating (per ASTM E 84 and UL 723 and CAN /ULC S102- M88) NFPA- 90B. The insulation R -value is 4.1. All cut edges of insulation are completely encapsulated in metal to prevent erosion. Air Valve & Fan Description (Parallel) (Series) • The air inlet connection is an 18 gauge galvanized steel cylinder sized to fit standard round duct. A multiple point, averaging flow sensing ring is provided with balancing taps for measuring airflow within +/- 5% of unit cataloged airflow. Also provided with each unit is a calibration chart indicating airflow versus flow sensor pressure differential. The damper blade is constructed.of a closed cell foam seal mechanically locked between two 22 gauge galvanized steel disks. The damper blade assembly is connected through a composite nylon stub axle to a cast zinc shaft supported by self lubricating bearings. The shaft is cast with a damper position indicator. The valve assembly includes a mechanical stop to prevent over stroking. Air valve leakage <1% at 4 ". _ 1004SQ Air Valve /Fan Combination Size (Parallel) 10" Inlet designed for up to 1400.0 cfm. Fan is 1350.0 cfm for Std Motor and 1510.0 cfm for ECM Motor. Motor Single Speed, direct drive induction, permanent split capacitor type. Thermal overload protection provided. Motors will be designed specifically for use with an open SCR which is standard. Motors will accommodate anti - backward rotation at start up. Motor and Fan assembly are isolated from terminal unit. Transformer The 50 VA transformer is factory mounted in the fan control box to provide 24 VAC for controls. Fuse Any electric heat unit with a calculated MCA greater or equal to 30 will have a fan fuse provided. SCR- Variable Fan Speed Control: Switch The SCR speed control device allows the operator infinite fan speed adjustment so the fan output may be modified to achieve exact CFM requirements. Electric Heat Coil Factory provided and mounted. ULrecognized, resistance open -type heater, a disc -type automatic thermal primary safety device and manual reset load thermal secondary device. Heater element material is nickel- chromium. The heater terminal box is provided with 7/8" knockouts for customer power supply. Terminal connections are plated steel with ceramic or phenolic insulators. All fan-powered units with electric reheat are single-point ower n P power connections. For 480 volt 3 phase and 575 volt 3 phase heaters a 4 wire (includes neutral) power supply is required. Electric Heat Coil Factory provided and mounted. Resistance open -type heater, a disc -type automatic thermal primary safety device and manual reset load thermal secondary device. Heater element material is nickel- chromium. The heater terminal box is provided with knockouts for customer power supply. Terminal connections are plated steel with ceramic or phenolic insulators. All fan - powered units with electric reheat are single -point power connections. For 480 volt 3 phase and 575 FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 4 of 14 Others • Wetzel's Pretzels May 16, 2011 • volt 3 phase heaters a 4 wire (includes neutral) power supply is required. • Magnetic Contactor An electric heater 24'volt contact for• use with Direct Digital Control (D.D.C.) or Analog Electronic VAV:Controls. Power Disconnect Switch (for VSEF & VPEF) A factory provided interlocking door. disconnect switch located on the electric heater control panel. • Airflow Switch An air pressure device designed to disable the heater when the unit fan is off. Power Fuse A safety fuse located in the electric heater's line of power to prevent power surge damage to the electric heater. Slip & Drive Connection A slip and drive connection has two straight flanges on the top and bottom, and two drive connections on the left and right sides. The drive sides are straight flanges which form a "U" shape. The mating ductwork has a similar setup. The two top and bottom pieces are shaped like a compressed "S" with sealant in the hollow of the "S ". These pieces will slide over the top and bottom straight flanges. The top and bottom flanges of the mating ductwork will slide into the other side of these pieces. The two side pieces are shaped like a "C" and are called "Drives ". These pieces will slide over the "U" shaped flanges so the connection can not be pulled apart. These pieces are usually hammered into place. No screws are required, and by removing the drives, the ducts may be disconnected. • • D.D.C. Actuator Trane 3 wire, 26 GA, 3.4 VA, 1.7W,- 24 VAC, 50/60 Hz. with floating point control actuator with linkage release button. Running torque is 35 in -lb minimum; and is non- spring return with 90 second drive time. Travel is terminated by end • stops at fully opened and closed positions. An integral magnetic clutch eliminates motor stall when Trane controls are not provided. An integral 3 screw terminal is provided for field wiring. Operating temperature 32.0 F to 125.0 F. Direct Digital Controller • The microprocessor based terminal unit controller provides accurate, pressure independent control through the use of a proportional integral control algorithm and direct control technology. The controller monitors zone temperature set points, zone temperature and its rate of change, and valve airflow, using a differential pressure signal. Optionally, the controller can monitor either supply duct air temperature or CO2 concentration via appropriate sensors. The controller and pressure transducer are installed and factory wired in an enclosure with 7/8" knockouts for remote control wiring. A Trane zone sensor is required. • System Communications The Controller is designed to send and receive data from a Central Control Panel or. other Tracer family products, or a VariTrac CCP. Current unit status conditions and set points may be monitored and /or edited via this data communication feature. The network type is a twisted wire pair serial communication. Override Commands The following override commands may be received by the Unit Control Module (U.C.M.) from the Tracer System. Control Mode, Action, & Offset (1.thru 12) 1. Control Mode - The U.C.M. Control Mode may be edited from occupied to unoccupied to accommodate night setback/setup. 2. Control Action- The Control Action may be edited from cooling to heating, changing the primary air damper to a heating source. This will accommodate a cooling /heating changeover system: 3. Control Offset- Enabling Control Offset will increase the cooling temperature set point and decrease the heating temperature set point by a control offset value stored at the U.C.M. This function facilitates demand limiting in the occupied mode. 4. Drive damper fully open. 5. Drive damper fully closed. 6. Drive damper to maximum airflow set point. 7. Drive damper to minimum airflow set point. 8. Disable unit fan. 9. Disable unit heat. 10. Reset- Enabling the reset function forces the controller and the flow sensor to recalibrate. 11. Programmable hot water valve drive time. 12. Programmable air valve drive time. FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 5 of 14 Others ' Wetzel's Pretzels May 16, 2011 ' Following Unit Set points The following unit set points reside in the U.C.M. in nonvolatile memory. These set points are editable from the Command Unit or Tracer via the communications link. Set points in Nonvolatile Memory (1 thru 8) 1. Occupied cooling temperature set point 60.0 F - 80.0 F. 2. Occupied heating temperature set point 60.0 F - 80.0 F. 3. Unoccupied cooling temperature set point 60.0 F - 100.0 F. 4. Unoccupied heating temperature set point 30.0 F - 100.0 F. 5. Minimum cooling flow set point (0, 10 - 100% of unit equivalent cataloged airflow). 6. Minimum heating flow set point (0, 10 - 100% of unit equivalent cataloged airflow). 7. Maximum flow set point (0,10 - 100% of unit equivalent cataloged airflow). 8. Fan Control Offset - This determines at what operating point the fan in a parallel fan powered unit is energized. This can be specified as a function of temperature, degrees above heating set point, or primary airflow. 0.0 F - 10.0 F or 0, 10 - 100% of unit equivalent cataloged airflow). Set points in Nonvolatile Memory (9 Thru 15) 9. Heating Set point Offset - This determines at what point the 1st. stage of reheat turns on. Expressed in degrees below cooling set point, only applicable when local thumb wheel is enabled. 10. Zone temperature, auxiliary temperature, and zone set point calibration corrections ( +/- 10.0 F). 11. Flow measurement calibration correction (50 - 150 %). 12. Cooling Set point Low Limit - Applies low limit to programmed occupied cooling set point or zone sensor cooling set point (30.0 F - 100.0 F). 13. Heating Set point High Limit - Applies high limit to programmed occupied heating set point or zone sensor heating set point (30.0 F - 100.0 F). 14. RTD / Thermistor - Determines what type of zone temperature sensor will be used. 15. Occupied and Unoccupied Outside Air Requirements - Determines the percent of outdoor air required in the zone for air quality requirements. Set points in Nonvolatile Memory (16 thru 21) 16. Series Fan Configuration- allows option of series fan powered box to shut off fan and close air valve when unit is unoccupied. Fan will operate in unoccupied mode if reheat is active. 17. Heating set point low limit. 18. Cooling set point high limit. 19. Local heating flow set point enable /disable & set point. 20. Auxiliary analog input mode select for either auxiliary temperature sensor or CO2 detector. 21. Binary input mode select for either generic or occupancy detector. Additional Status Information (1 thru 8) In addition to the above set points, the following status information can be transmitted to the Command Control Unit and Tracer. 1. Active cooling temperature set point. 2. Active heating temperature set point. 3. Current unit primary airflow. 4. Current zone temperature. 5. Re -heat status (On /Off). 6. Auxiliary Air Temperature - Available only if the unit has an auxiliary temperature sensor. 7. Failure Indicators - The U.C.M. will indicate the following: *Temperature Sensor Failure *Flow Sensor Failure *Local Zone Sensor Set point Failure 8. Ventilation Ratio. Additional Status Information (9 thru 12) 9. Fan Status (on /off) 10. Calibration Status (calibrating /not- calibrating) 11. BIP state 12. CO2 Concentration- available only if the unit has an auxiliary CO2 sensor. This mode and auxiliary air temperature are mutually exclusive. DDC Sequence of Operation The unit controller continuously monitors the zone temperature against its set point and varies the primary airflow as required to meet zone set points. Airflow is limited by minimum and maximum airflow set points. FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 6 of 14 Others . Wetzel's Pretzels May 16, 2011 • ' Parallel Unit Fan Energization • • : As the zone temperature reachesithe heating set point, the microprocessor controls airflow to the heating temperature set point and energizes the auxiliary fan when necessary. At or below the heating set point, reheat is energized. The heating minimum airflow set point is factory set, field adjustable, and is separate from the cooling minimum set point. Parallel unit fan energization is a function of primary airflow or zone temperature. • 1. Primary Airflow - The fan energizes when primary airflow drops below the fan set point airflow. The fan automatically - starts when the zone temperature drops to the heating temperature set point. • 2. Zone Temperature - The fan energizes when the zone temperature drops to a selectable number of degrees above the heating temperature set point. Controls Option DD05 Basic Operation: Slow Pulse Width Electric Heat (Normally Open Outputs) (DDC /UCM) (Parallel Units) A voltage signal from the zone sensor indicating zone temperature is used by the unit controller to determine an error from the set point. This error, as well as primary flow differential pressure, is used to determine damper position within minimum and maximum cooling airflow set points. As the zone temperature reaches the heating set point, primary airflow is controlled to the minimum heating flow set point. The fan operation is intermittent in both modes and is energized as the first stage of heat. Two stages of electric heat are modulated using the slow pulse width method for unit reheat. DDC Zone Sensor w /Setpoint & Occupancy This electronic device utilizes a thermistor to vary the voltage output in response to changes in the zone temperature. Wiring to the U.C.M. controls must be 18 to 22 awg. shielded twisted pair wiring. The setpoint adjustment range is 50.0 F 88.0 F. This sensor is provided with an externally adjustable set point, a timed override button and a timed override cancel button. An optional communications jack is available which snaps into the enclosure backplate. • • • • • • • • FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 7 of 14 Others • • •Wetzel's Pretzels • • .. May 16, 2011' • . ' Unit Dimensions- Variable Air - Volume Fan Powered Terminal Units . . . • Item: Al ' Qty: 1 Tag(s): FP -1. • • • • Unit Size. VPEF1004S0 Nominal 10' Dia..x 4' Depth ' Valve Size 8 Depth Nominal 04SO Fan >i'•e <.� Fan Size ..,9 >\. ?.fey >.,• t �'t.�. e, 1,�. Filter Size 16' x 20' x1" (OTY 1) `,? , �;,V.k. • .q..i tip.. <: , • TOP VIEW • • 20' . • "n•o-101 ' I s• 00 n A NOTES: AIRFLOW 16.50 x 11.30 31 I 1. Allow a minimum 6' plenum inlet clearance 1 y , t 1 for un-ducted installations. 2. Filter is secured in filter frame located in unit inlet. 32 12• 3. For Motor access, remove bottom screws on • hanger brackets to slide panel as shown in drawing. 4. See Installation Documents for exact hanger 3 z bracket location. 22 m • _ 5. Air valve centered between top & bottom panel. • i O 6. be Healing field coil supplied un- insulated. and installed External as required. insulation may HEATER m 6• 7. All high & low voltage controls have same -side NEC jumpback clearance. ' PANEL SLIDES FOR MOTOR ACCESS 8. Allow 48' of straight duct downstream of AIRFLOW unit before first runout and inside of the duct should DISCHARGE OUTLET be equal discharge size. 9. Terminal box access door is side hinged. Allow for clearance. • I 10. A 4 wire power supply required for 480\3 & 575 \3 5' 1 • 40' � single point connection units. T 1 16' 17 1/2' Approximate 114.01b 4 Dry Weight Weights reflected may vary 20 ±5.0 lb based upon options • DISCHARGE VIEW selected. FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 8 of 14 Others • . Wetzel's Pretzels • May 16, 2011 Accessory - ;Variable. Air' Volume` Fan Powered Terminal Units . • • • •Item: Al Qty: 1 • ,Tag(s FP -1 • • • 96.00 0.48 3.40 REF • REF 2.00 0.25 t 0.50 2.00 �� re ) 1.50 — s e � � 1 0.31 \I 1/4' Insulated DC's 6 0.25 Diameter, 2 Holes PROBE 0.50 — 1.00 — a SPECIFICATIONS: • 1.) Sensing element: thermistor located in probe tip • and sealed in thermally conductive adhesive. • 2.) Probe sheath: Light drawn thin wall copper tubing. 3.) Assembly ambient limits: Shipping and storage temperature is -40.0 F to 160.0 F. Operating temperature Is -4.0 F tO 212.0 F. Humidity: 5% to 95% RH non-condensing. 4.) Mounting: any position on duct. 5.) Packaging: Each unit packed in individual plastic bag w /two #10 -314' long sheet metal mounting screws and information sheet w /the following information visible: 'ELECTRONIC DUCT TEMP SENSOR' 6.) Cable is 300V type CL2P with jacket rated at 257.0 F and wires 22 AWG stranded tinned copper. FLD = Furnished by Trane U.S. Inc. /Installed by Equipment Submittal Page 9 of 14 Others Wetzel's Pretzels May 16, 2011 Accessory - Variable Air Volume Fan Powered Terminal Units Item: Al Qty: 1 Tag(s): FP -1 Notes: 1. When attenuator is required, add inlet attenuator pressure to discharge static pressure for final fan performance. VPCF and VPEF maximum Minimum 1 -row coil maximum - •- •- • -• -• -• 2 -row coil maximum Pa In. wg Parallel O4SQ —PSC 199 0.80 '. . \ \ 174 0.70 • •\ \ \ ID 150 0.60 ` ` \ \ \ \ 125 0.50 E y ` S. a C 5 \ a t o I°. ` t o 100 0.40 c. \ \ \ m \ \ vi m 75 0.30 ` • \ \ c \ \ N • 50 0.20 \ \ \ \ \ 25 0.10 200 400 600 800 1000 1200 1400 1600 Cfm 94 189 283 378 472 566 661 755 Us Airflow • FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 10 of 14 Others Wetzel's Pretzels May 16, 2011 Accessory - Variable Air Volume Fan Powered Terminal Units Item: Al Qty: 1 Tag(s): FP -1 0 41116• lUf O TRANE 27/8" 0 1 Customer Notes: 1. Zone Sensor with externally adjustable setpoint, a timed override button & a timed override cancel button. 2. Optional communications jack available. FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 11 of 14 Others Wetzel's Pretzels May 16, 2011 Field Wiring - Variable Air Volume Fan Powered Terminal Units Item: Al Qty: 1 Tag(s): FP -1 208 Volt, 3 Phase L3 U L1 N I I I I I I I I I I I I I I I I I T N Heater Control Wiring ® WARNING HAZARDOUS VOLTAGE! DISCONNECT ALL ELECTRIC POWER INCLUDING REMOTE DISCONNECTS BEFORE SERVICING. FAILURE TO DISCONNECT POWER BEFORE SERVICING CAN CAUSE SEVERE PERSONAL INJURY OR DEATH L CAUTION USE COPPER CONDUCTORS ONLY! UNIT TERMINALS ARE NOT DESIGNED Customer Notes: TO ACCEPT OTHER TYPES OF 1. Factory installed. CONDUCTORS. FAILURE TO DO SO MAY CAUSE — — — — Optional or installed by others. DAMAGE TO THE EQUIPMENT. FLD = Furnished by Trane U.S. Inc. /Installed by Equipment Submittal Page 12 of 14 Others Wetzel's Pretzels May 16, 2011 ' Field Wiring - Variable Air Volume Fan Powered Terminal Units Item: Al . Qty: 1 Tag(s): FP -1 . , • HEATER • TERMINAL DAMPER BOX WIRING ACTUATOR FAN CONTROL - WIRING BOX WIRING - _ ... _ - �_ r T81 -1 T82-0 TB33 TB &1 • TB1-2 I TB25 I TB3-2 I - I -- -- I —_ I I � I � 1 � I • 2ND STG HEAT 6 6 6 6 6 6 11 10 7 6 3 2 1 >I Z H DIGITAL DISPLAY ZONE SENSOR 0 0 O WI COMM. JACK 1ST STG HEAT m REMOTE MTD. I 0 .(1 ‘0 I • OPTIONAL FIELD INSTALLED L DIGITAL DISPLAY ZONE SENSOR J R -FAN I BR r TB25 T93-1 7 Y 1 TB2.5 TB3-2 0 1 1 T03-3 1 1 > O m \ m 24VAC BL 1 I ! 1 I I jirrr'''!!III ` JII000000 1 ry ^ 6 6 i6 6 6 of C19 '- .4[ AGT a � m 2(') !(•J 3 2 1 ZONE SENSOR BIP GND 24V PRESSURE W/ COMM. JACK TRANSDUCER REMOTE MTD. ADDRE D.D.C. \U.C.M. aQ J 3 SWITCH CONTROL BOARD R + OPTIONAL FIELD w� BK I VOUT L INSTALLED ZONE SENSOR J MBE a 0 I. o o 1 • m� .cl N� : 0 N0 TEL GRN Ff Frj F� F1 f, O 7, I 24V (T91•11 24V m I Y I m m m m J CO2 SENSOR GND 0 (783 -0) GND _ ZONE GND SET A/CO2 GND OUT V (1' B35IA/CO2 . OPTIONAL FIELD INSTALLED L CO2 SENSOR D.D.C. \U.C.M. S E o o • CONTROL BOX OPTIONAL • BL FACTORY I' INSTALLED Y WIRELESS SHIELDED TWISTED PAIR OPTIONAL FACTORY INSTALLED r TB3-5 — I I TB35 1 1 COMMUNICATIONS WIRING WIRELESS I I _— Y 1 I r �� 24VAC BL �. 1 I R(HOT) _ (TB1- 1)24VAC - O(COMMONI_ —_ (T84 -1)BIP C m' m' _GR (NC CONTACT) _ (TB1.1) 24VAC BKSRETURNI_ — _ GND 24V (TB1 -2) GND OPTIONAL • Y — — — — - NOT CONNECTED L AUX TEMP SENSO J W550 Boots L OPTIONAL FIELD INSTALLED L OCCUPANCY SENSOR J NOTE: ZN WARNING • • 1. FACTORY WIRING FIELD WIRING HAZARDOUS VOLTAGE! - - - - OPTIONAL OR ALTERNATE WIRING DISCONNECT ALL ELECTRIC POWER INCLUDING REMOTE DISCONNECTS 2. 1/4 QUICK CONNECT REQUIRED FOR ALL FIELD CONNECTIONS. BEFORE SERVICING. ZONE SENSOR TERMINALS 1 ( -) AND 2 ( +) REQUIRE SHIELDED TWISTED PAIR WIRING FOR COMMUNICATIONS B BEEFOFORE SE TO DISCONNECT POWER ERVICING CAN CAUSE JACK EQUIPPED ZONE SENSOR OPTION. SEVERE PERSONAL INJURY OR DEATH • Q NO ADDITIONAL WIRING REQUIRED FOR NIGHT SETBACK OVERRIDE (ON /CANCEL). CAUTION ION THE OPTIONAL BINARY INPUT CONNECTS BETWEEN TB4 -1 (BIP) AND 24VAC (HOT) FROM USE COPPER CONDUCTORS ONLY! TRANSFORMER. INPUT CAN BE RECONFIGURED AS AN OCCUPANCY INPUT VIA THE COMMUNICATIONS UNIT TERMINALS ARE NOT DESIGNED INTERFACE. TO ACCEPT OTHER TYPES OF AS SHIPPED. THE AUX INPUT IS CONFIGURED AS AN AUX TEMP INPUT. THE AUX INPUT CAN BE CONDUCTORS. RECONFIGURED AS A CO2 SENSOR INPUT VIA THE COMMUNICATIONS INTERFACE. FAILURE TO DO SO MAY CAUSE S TERMINAL NOT TO BE USED WITH VARITRANE. DAMAGE TO THE EQUIPMENT. • Q ZONE SENSOR TERMINALS 6 AND 7 REQUIRE SHIELDED TWISTED PAIR WIRING FOR OPTIONAL USE OF COMMUNICATIONS JACK. FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 13 of 14 . Others Wetzel's Pretzels May 16, 2011 ' Field Installed Options - Part/Order Number Summary This is a report to h elp you locate field installed options that arrive at the jobsite. This report provides part or order numbers for each field installed option, and references it to a specific product tag. It is NOT intended as a bill of material for the job. • Product Family - Variable Air Volume Fan Powered Terminal Units • I Item. _ Tag(s) . Qty Description - - Model- Number . . . • . Al FP -1 1 VAV Fan Powered Terminal Units VPEF1004SQ I Field Installed Option Description Part/Ordering Number DDC sensor with set point knob and occupancy X13511527010 DDC auxiliary temperature sensor X13790068050 • • • FLD = Furnished by Trane U.S. Inc. /Installed by Equipment Submittal Page 14 of 14 Others [Page Too Large for OCR Processing] [Page Too Large for OCR Processing]