Loading...
Specifications ..1 ,p2o l -coo 3 3 • 95oz WAAL. 57 Roe COMcheck Software Version 3.8.0 . EC C-2.. -IP Interior Lighting Compliance R -P1J v.' c-L) Certificate FEB 2011 CITY OF T IGA RD Oregon Energy Efficiency Specialty Code BUILDING DIVISION Section 1: Project Information Project Type: New Construction Project Title : Wetzel's Pretzels Construction Site: Owner /Agent: Designer /Contractor: Washington Square Mall Laurie Keys Daniel A. Reeves, PE Space J03 Wetzel's Pretzels 3100 E Randol Mill Rd 11 Wellington Place Arlington, TX 76011 Aliso Viejo, CA 92656 817 - 701 -4808 949- 215 -3187 dreeves @pdmsdesign.com Section 2: Interior Lighting and Power Calculation A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts / ft2 (B x C) Service Area (Common Space Types:Food Preparation) (Ceiling Height 13 ft.) 296 1.07 317 Storage Area (Common Space Types:Food Preparation) (Ceiling Height 11 ft.) 255 1.07 273 Toilet Room (Common Space Types:Restrooms) (Ceiling Height 8 ft.) 49 0.82 40 Total Allowed Watts = 630 Section 3: Interior Lighting Fixture Schedule A B C D E Fixture ID : Description I Lamp / Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D) Fixture Fixtures Watt. Service Area ( Common Space Types:Food Preparation 296 sq.ft.) HID 1: B1: CMH Downlight / Ceramic Metal Halide 39W / Standard 1 18 39 Exempt Exemption:Food Preparation Equipment Track lighting 1: Cl: Wattage based on 4.0 feet of track 0 0 0 200 Storage Area ( Common Space Types:Food Preparation 255 sq.ft.) Linear Fluorescent 1 copy 1: Al: 2x4 Fluor. Troffer / 48" T8 32W / Electronic 2 5 58 290 Toilet Room ( Common Space Types:Restrooms 49 sq.ft.) Linear Fluorescent 1: Al: 2x4 Fluor. Troffer / 48" T8 32W / Electronic 2 1 58 58 Total Proposed Watts = 548 r Section 4: Requirements Checklist Lighting Wattage: 1. [505.1 +] Total proposed watts must be less than or equal to total allowed watts. Allowed Watts Proposed Watts Complies 630 548 • YES In the following requirements, the relevant code section reference is shown in [ ]. ' +' denotes that more details exist in the specified code section. Mandatory Requirements: Project Title: Report date: Data filename: Page 1 of ❑ 2. [505.4] Exit signs. Internally illuminated exit signs shall not exceed 5 watts per side. Location in plans/specs where compliance can be identified (enter NA if not applicable): ❑ 3. [505.2.2.3 +] Daylight zone control. All daylight zones are provided with individual controls that control the lights independent of general area lighting in the non - daylight zone. In all individual daylight zones larger than 350 sq.ft., automatic daylight controls is provided. Automatic daylight sensing controls reduce the light output of the controlled luminaires at least 50 percent, and provide an automatic OFF control, while maintaining a uniform level of illumination. Contiguous daylight zones adjacent to vertical fenestration may be controlled by a single controlling device provided that they do not include zones facing more than two adjacent cardinal orientations (i.e., north, east, south, west). Daylight zones under skylights shall be controlled separately from daylight zones adjacent to vertical fenestration. • Exceptions: • ❑ Retail spaces adjacent to vertical glazing (retail spaces under overhead glazing are not exempt). ❑ Display, exhibition and specialty lighting ❑ HID lamps 150 watts or less. ❑ Spaces required to have occupancy sensors. Location in plans/specs where compliance can be identified (enter NA if not applicable): ❑ 4. [505.2.1 +] Interior lighting controls. At least one local shutoff lighting control has been provided for every 2,000 square feet of lit floor area and each area enclosed by walls or floor- to-ceiling partitions. The required controls are located within the area served by the controls or are a remote switch that identifies the lights served and indicates their status. Exceptions: ❑ Lighting systems serving areas designated as security or emergency areas that must be continuously lighted. ❑ Lighting in public areas such as concourses, stairways or corridors that are elements of the means of egress with switches that are accessible only to authorized personnel. ❑ Lighting for warehouses, parking garages or spaces using less than 0.5 watts per square foot. ❑ Lighting for contiguous, single- tenant retail spaces. Location in plans/specs where compliance can be identified (enter NA it not applicable): ❑ 5. [505.2.3 +] Sleeping unit controls. Master switch at entry to hotel /motel guest room. Location in plans/specs where compliance can be identified (enter NA it not applicable): ❑ 6. [505.2.1.1] Egress lighting. Egress illumination is controlled by a combination of listed emergency relay and occupancy sensors to shut off during periods that the building space served by the means of egress is unoccupied. Exceptions: ❑ Building exits as defined in Section 1002 of the Oregon Structural Specialty Code. Location in pans/specs where compliance can be identified (enter NA it not applicable): ❑ 7. [505.2.2 +] Additional controls. Each area that is required to have a manual control shall have additional controls that meet the requirements of Sections 505.2.2.1 and 505.2.2.2. ❑ 8. [505.2.2.1 +] Light reduction controls. Each space required to have a manual control also allows for reducing the connected lighting load by at least 50 percent by either 1) controlling (dimming or multi -level switching) all luminaires; or 2) dual switching of alternate rows of luminaires, alternate luminaires, or alternate lamps; or 3) switching the middle lamp luminaires independently of other lamps; or 4) switching each luminaire or each lamp. Exceptions: ❑ Only one luminaire in space. ❑ An occupant- sensing device controls the area. ❑ The area is a corridor, storeroom, restroom, public lobby or sleeping unit. ❑ Electrical and mechanical room. ❑ Areas that use less than 0.6 Watts/sq.ft. Location in plans/specs where compliance can be identified (enter NA if not applicable): ❑ 9. [505.2.2.2] Buildings larger than 2,000 square feet are equipped with an automatic control device to shut off lighting in those areas. - t This automatic control device shall function on either: 1) a scheduled basis, using time -of -day, with an independent program schedule that controls the interior lighting in areas that do not exceed 10,000 square feet and are not more than one floor; or Project Title: Report date: Data filename: Page 2 of 2) an occupant sensor that shall turn lighting off within 30 minutes of an occupant leaving a space; or 3) a signal from another control or alarm system that indicates the area is unoccupied. Exceptions: [) Sleeping units, patient care areas; and spaces where automatic shutoff would endanger safety or security. Location in plans/specs where compliance can be identified (enter NA if not applicable): 0 10. [505.2.2] Occupancy sensors in rooms that include daylight zones are required to have Manual ON activation. • Location in plans/specs where compliance can be identified (enter NA it not applicable): O 11. [505.2.2] An occupant sensor control device is installed that automatically turns lighting off within 30 minutes of all occupants leaving a space. Exceptions: Li Classrooms and lecture halls. O Conference, meeting and training rooms. LI Employee lunch and break rooms. ❑ Rooms used for document copying and printing. O Office spaces up to 300 square feet. O Restrooms. L) Dressing, fitting and locker rooms. Location in plans/specs where compliance can be identified (enter NA if not applicable): • 12. [505.2.2] Additional controls. An occupant sensor control device that automatically turns lighting off within 30 minutes of all occupants leaving a space or a locally activated switch that automatically turns lighting off within 30 minutes of being activated is installed in all storage and supply rooms up to 1000 square feet. Location in plans/specs where compliance can be identified (enter NA if not applicable): Li 13. [505.2.2.2.1] Occupant override. Automatic lighting shutoff operating on a time -of -day scheduled basis incorporates an override switching device that: 1) is readily accessible, 2) is located so that a person using the device can see the lights or the area controlled by that switch, or so that the area being lit is annunciated, 3) is manually operated, 4) allows the lighting to remain on for no more than 2 hours when an override is initiated, and 5) controls an area not exceeding 2,000 square feet. Exceptions: Li In malls and arcades, auditoriums, single- tenant retail spaces, industrial facilities and arenas, where captive -key override is utilized, override time is permitted to exceed 2 hours. LI In malls and arcades, auditoriums, single- tenant retail spaces, industrial facilities and arenas, the area controlled shall not exceed 20,000 square feet. Location in plans/specs where compliance can be identified (enter NA if not applicable): • 14. [505.2.2.2.2] Holiday scheduling. Automatic lighting shutoff operating on a time-of-day scheduled basis has an automatic holiday scheduling feature that turns off all loads for at least 24 hours, then resumes the normally scheduled operation. Exceptions: O Retail stores and associated malls, restaurants, grocery stores, places of religious worship, theaters and exterior lighting zones. L i Single zone electronic time control devices and self - contained wall box preset lighting controls. Location in plans/specs where compliance can be identified (enter NA if not applicable): ❑ 15. [505.2.4 +] Exterior lighting controls. Lighting not designated for dusk- to-dawn operation shall be controlled by either a combination of a photosensor and a time switch, or an astronomical time switch. Lighting designated for dusk -to -dawn operation shall be controlled by an astronomical time switch or photosensor. Location in plans/specs where compliance can be identified (enter NA if not applicable): Li 16. [505.3] Tandem wiring. The following luminaires located within the same area shall be tandem wired: 1. Fluorescent luminaires equipped with one, three or odd - numbered lamp configurations, that are recess- mounted within 10 feet center -to- center of each other. 2. Fluorescent luminaires equipped with one, three or any odd - numbered lamp configuration, that are pendant- or surface - mounted within 1 foot edge- to -edge of each other. Exceptions: Li Where electronic high- frequency ballasts are used. Project Title: Report date: Data filename: Page 3 of Li Luminaires on emergency circuits. LJ Luminaires with no available pair in the same area. Location in plans/specs where compliance can be identified (enter NA if not applicable): D 17. [505.5.1 +] Medical task lighting or art/history display lighting claimed to be exempt from compliance has a control device independent • of the control of the nonexempt lighting. Location in plans/specs where compliance can be identified (enter NA if not applicable): L] 18. [505.7 +] Each dwelling unit in a building is metered separately. Location in plans/specs where compliance can be identified (enter NA if not applicable): Interior Lighting'PASSES: Design 13 %, better than code' . Section 5: Compliance Statement Compliance Statement: The proposed lighting design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed lighting system has been designed to meet the Oregon Energy Efficiency Specialty Code requirements in COMcheck Version 3.8.0 and to comply with the mandatory requirements in the Requirements Checklist. • Name - Title Signature Date P i 0fi 1k4 v 81368PE � I//// OREGON 1A, ' 13 2' A C A. , (RENEWAL DATE__ . 1213/b . Project Title: Report date: Data filename: Page 4 of