Plans[Page Too Large for OCR Processing] FP 2 - - oao7 I 7.10 9 S v✓ 60 Pkwy Zoo , t qcci 'Fire & Building i Products CON: E - Technical Services: Tel: (800) 381 -9312 / Fax: (800) 791 -5500 JU GI 5 5° irinPaD Series TY -FRB — 2.8, 4.2, 5.6, and 8.0 pactiyi Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General tamed when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the Description standard corrosion tests of the appli- ' cable approval agencies, the testing is _ The Tyco® Series TY -FRB, 2.8, 4.2, not representative of all possible cor- 5.6, and 8.0 K- factor, Upright and Pen- rosive atmospheres. Consequently, it . dent Sprinklers described in this data is recommended that the end user be I I lip • sheet are quick response - standard consulted with respect to the suitability coverage, decorative 3 mm glass bulb of these coatings for any given corro- type spray sprinklers designed for use sive environment. The effects of ambi- in light or ordinary hazard, commercial ent temperature, concentration of o tz. ccupancies such as banks, hotels, chemicals, and gas /chemical velocity, — shopping malls, etc. should be considered, as a minimum, The recessed version of the Series along with the corrosive nature of the TY -FRB Pendent Sprinkler, where ap- chemical to which the sprinklers will be exposed. ^` plicable, is intended for use in areas p with a finished ceiling. It uses either a An intermediate level versions of the ..-; two -piece Style 10 (1/2 inch NPT) or Series TY -FRB Pendent Sprinklers ,' , .\ \ • Style 40 (3/4 inch NPT) Recessed Es- are detailed in Technical Data Sheet t • • cutcheon with 1/2 inch (12,7 mm) of TFP356, and Sprinkler Guards are de- 1 recessed adjustment or up to 3/4 inch tailed in Technical Data Sheet TFP780 1 , (19,1 mm) of total adjustment from the t flush pendent position, or a two -piece WARNINGS Style 20 (1/2 inch NPT) or Style 30 (3/4 The Series TY -FRB Sprinklers de- "` inch NPT) Recessed Escutcheon with scribed herein must be installed and , ' 1/4 inch (6,4 mm) of recessed adjust- maintained in compliance with this ment or up to 1/2 inch (12,7 mm) of document, as well as with the applica- total adjustment from the flush pen- ble standards of the National Fire Pro - dent position. The adjustment pro- tection Association, in addition to the vided by the Recessed Escutcheon re- standards of any other authorities hav- Model/Sprinkler duces the accuracy to which the fixed ing jurisdiction. Failure to do so may pipe drops to the sprinklers must be impair the performance of these de- Identification cut. vices. Corrosion resistant coatings, where The owner is responsible for maintain- Numbers applicable, are utilized to extend the ing their fire protection system and de- life of copper alloy sprinklers beyond vices in proper operating condition. TY1131 - Upright 2.8K, 1/2 "NPT that which would otherwise be ob- The installing contractor or sprinkler TY1231 - Pendent 2.8K, 1/2 "NPT manufacturer should be contacted TY2131 - Upright 4.2K, 1/2 "NPT IMPORTANT with any questions. Pendent TY3131 - Upright 5.6K, 1/2 "NPT Always refer to Technical Data TY3231 - Pendent 5.6K, 1/2 "NPT Sheet TFP700 for the "INSTALLER TY4131 - Upright 8.0K, 3/4 "NPT WARNING" that provides cautions TY4231 - Pendent 8.0K, 3/4 "NPT with respect to handling and instal- TY4831- Upright 8.0K, 1/2 "NPT lation of sprinkler systems and com- TY4931- Pendent 8.0K, 1/2 "NPT ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- • nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 AUGUST, 2007 TFP171